Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.3 LAccepted-AOC IV 356 RAMANTHALI PAYYANUR KANNUR DIST KERALA 670308 | PAYYANUR | KANNUR | KERALA | 670308 | L1 | Accepted-AOC Being lowest. | |
| 2 | L2₹40.4 L+₹97,910.70 (2.49%)Rejected-Finance PMC 24 528 GROUND FLOOR NEAR PAYYANUR SERVICE CO OP BANK KOTTY BRANCH PAYANNUR KANNUR KERALA 670307 | PAYYANUR | KANNUR | KERALA | 670307 | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹41.1 L+₹1.7 L (4.21%)Rejected-Finance DOOR NO 3 79 CHENNNADGRAMAPANCHAYAT PERUMBALA KASARAGOD 681317 | PERUMBALA | KASARAGOD | KERALA | 681317 | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹43.1 L+₹3.7 L (9.39%)Rejected-Finance RP IV 23 PUNNAKADAVU JN RAMANTHALI P O KANNUR 670308 | KANNUR | KANNUR | KERALA | 670308 | L4 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹43.9 L
EMD Value
₹87,700
Closing Date
17 Oct 2022, 6:00 pmClosed
GE(MAINT)EZHIMALA
GARRISON ENGINEER (MAINT) MILITARY ENGINEER SERVICES INDIAN NAVAL ACADEMY POST KANNUR DIST KERALA 670 310
AS PER BOQ AND TENDER DOCUMENTS
2022_MES_553023_1
GE MAINT EZHIMALA 8512
Open Tender
Civil Works
Item Rate
180 days
EZHIMALA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MAINT EZHIMALA
₹87,700
Yes
18 Nov 2022
20 Sept 2022
19 Oct 2022
20 Sept 2022
17 Oct 2022
4 Oct 2022
21 Sept 2022 - 28 Sept 2022
Amount
Surface excavation n.exc 30cm deep and averaing 15 cm deep and getting in hard / dense soil complete all as specified and as directed.
M&L for hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface of broken stone or boulders complete all as specified and as directed.
M&L for 100 mm thick PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) as in sub base complete all as specified and as directed.
M&L for 100 mm thick cement concrete 1:2:4 type B-1, (using 20mm graded granite stone aggregate) as in hard standing and making impression complete all as specified and as directed.
M&L for 50 mm thick sand filling for cushion bed below interlocking paver blocks complete all as specified and as directed.
M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-35 Grade with grey cement and pigment complete all as specified and as directed.
Removing excavated material exc. 250 m but n exc. 500 m and depositing where directed complete all as specified and as directed.
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface in hard/dense soil complete all as specified and as directed.
M&L for cement concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.
S&F posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc. flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similiar work conforming to Fe-290 Gde E-165 complete all as specified and as directed.
S&F PVC coated GI chain link fencing weighing 4kg/Sqm ( mesh 50 mm X 50 mm size) nominal dia of wire 3.5 mm ( including pvc coating ) fixed to fencing posts using suitable bolts and nuts complete all as specified and as directed. Note:- Nuts and bolts shall be measured and paid separately.
S&F mild steel screw bolts 10mm dia (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 5cm but n exc 10cm long complete all as specified and as directed.
M&L for preparation of new steel surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 finished even & smooth without using extra cement complete all as specified and as directed.
M&L for cement concrete 100mm thick type B-1, 1:2:4 (20mm graded aggregate) finished surface even and smooth without using extra cement complete all as specified and as directed.
M&L for cement concrete 1:3:6 type C-2, 75mm thick for plinth protection and finished even and smooth without using extra cement complete all as specified and as directed.
S&F steel work in tubular trusses including special shaped washers etc. complete using ERW or induction butt welded tubes conforming to IS 4923-1968 Grade St-240 for square or rectangular tube complete all as specified and as directed.
S&F framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similiar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed.
S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof overing/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing)/ removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
Taking down chowkats with shutter (without taking off shutter from the frame) exc 1.5 Sqm but n.exc 4.00 Sqm each complete all as specified and as directed.
Taking down chowkats with shutter (without taking off shutter from the frame) n.exc 1.50 Sqm each complete all as specified and as directed.
Taking down cement plaster of any description or thickness/ chipping of cement concrete in any situation from brick or concrete surface including raking out of joints, hacking for key scrubbing down with water to received new plaster complete all as specified and as directed.
Dismantling wall and ceiling boards (fiber, pulp, insulation etc.) or insulation boards/slabs/ any thickness including cover fillets complete all as specified and as directed.
S&F aluminium powder coated door shutter, side hung type aluminium section weighing not less than 0.55 Kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading, screws etc. (minimum thickness of powder coating not less than 50 micron) complete all as specified and as directed.
S&F aluminium powder coated windows and ventilator shutters etc. side hung type without sash bars,aluminium section weighing not less than 0.55 Kg/m including necessary joining cleats, glazing clips rubber neoprene packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No), hinges type B-21 100mm long (2 Nos) suitable handle (1 No) etc. (minimum thickness of powder coating not less than 50 micron) complete all as specified and as directed.
S&F aluminium powder coated door frame for doors, windows, ventilators with one or more rebates including joining cleats for fixing etc.(minimum thickness of powder coating not less than 50 micron) complete all as specified and as directed.
S&F 9mm thick pre-laminated particle board exterior grade, one side decorative choice lamination and other side balancing white lamination, fixed with screws to wooden / aluminium frame work as in cupboard shutters complete all as specified and as directed.
M&L for 4mm thick sheet glass plain ordinary quality not exc 0.50 sqm in each pane and glazing with beading complete all as specified and as directed. Note:- Aluminium beading shall be measured and paid separately.
S&F aluminum anodized wire cloth 0.45 mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminum wire staples complete all as specified and as directed.
S&F aluminum (die cast) body door closer hydraulically regulated designation No 2 universal type suitable for door shutters of 701 to 850mm in width and of weight between 36 to 60 Kg complete all as specified and as directed.
S&F floor door stopper 150mm size aluminium alloy body and tongue double legged, anodised with hard drawn steel spring fixed to door complete all as specified and as directed.
S&F mortice lock brass body, 100 mm, 4 levers vertical type complete all as specified and as directed.
S&F in repairs 200mm anodized aluminium barrel tower bolt of extruded section complete all as specified and as directed.
S&F wood grain printed PVC sheet 2mm thick fixed or laid on to flush doors by rubber based adhesive supplying & fixing at site as per specification complete all as specified and as directed.
M&L for coloured Non-skid ceramic tiles (square/rectangular) 7 to 10 mm thick in floors, area of each tile exc.0.11 sqm but n.exc 0.18 sqm, set and jointed in neat cement slurry and pointed in white cement mixed with matching pigment over and including 20mm thick screed bed in CM 1:6 complete all as specified and as directed.
M&L for Glazed ceramic coloured tiles 350x250x7mm / 450x300x 7mm thick in vertical surfaces of stone/brick wall, set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15mm thick backing coat plaster in CM 1:4 complete all as specified and as directed.
S&F in repair vitreous China wash basin,coloured (flat back) 500x450mm excluding pillar tap, but including fixing brackets, cutting for and pinning in ends of brackets complete all as specified and as directed.
S&F in repairs pillar taps 15 mm size, cast copper alloy, chromium plated screwed down high pressure screwed for iron pipe & fixed complete all as specified and as directed.
S&F in repair vitreous china, wash down water closet (pedestal pattern), cascade type including flushing cistern with seat cover coloured, closed pattern with flat bottom and cover with chromium plated mild steel or aluminium hinging device fixed with necessary bolts complete all as specified and as directed.
S & F in repair vitreous China Urinal, half stall type, coloured, with and including all fixing acessories complete all as specified and as directed.
S & F in repair vitreous China Urinal partition, coloured, with and including all fixing acessories complete all as specified and as directed.
S & F in repairs 15mm bore chromium plated bib taps (fancy type), cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipes complete all as specified and as directed.
S&F in repair angular stop valve, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, chromium plated, fancy type, screwed both ends for iron pipe or for union and fixed, suitable for 15 mm bore pipe complete all as specified and as directed.
S & F in repair brass chromium plated towel ring complete all as specified and as directed.
S & F in repair 20mm dia, D type, 60cm long cast copper alloy, chromium plated towel rail complete all as specified and as directed.
S & F in repair cast copper alloy, chromium plated toilet paper holder complete all as specified and as directed.
S&F in repair chromium plated soap tray fixed with CP brass screws complete all as specified and as directed.
S & F in repair health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified and directed.
S&F urinal spreader of PTMT any colour for fixing with 15 mm dia pipe (minimum weight 60gms) complete all as specified and as directed.
S & F in repairs 32mm dia PVC flexible waste pipe for urinals/ WHB /sink complete all as specified and as directed.
S & F in repair PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and as directed.
S & F in repair cast copper alloy, chromium plated waste coupling with long shank, half thread, 32 mm dia, for WHB etc. complete all as specified and as directed.
Taking up or down steel tubing and connections 15mm dia complete all as specified and as directed.
Taking up or down steel tubing and connections 20mm dia complete all as specified and as directed.
Taking up or down steel tubing and connections 25/32 mm dia complete all as specified and as directed.
Supplying and laying of 15 mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed.
Supplying and laying of 20 mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed.
Supplying and laying of 25 mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed.
Dismantling CI soil waste pipe 100mm/75 mm dia including all joints and branch pieces jointed in cement mortar complete all as specified and as directed.
S & F in repair PVC (SWR) pipes of 110 mm dia single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed.
S & F in repair PVC (SWR) pipes of 75mm dia single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed.
S & F PVC (SWR) pipes double socketed, in any length with rubber ring joints, laid in trenches or in floors of bore 75mm complete all as specified and as directed.
S & F PVC (SWR) bends any radius of bore 75mm complete all as specified and as directed.
S & F PVC (SWR) bends any radius of bore 110mm complete all as specified and as directed.
S & F PVC (SWR) junction single, (Single T) equal or unequal of bore 75mm complete all as specified and as directed.
S & F PVC (SWR) junction single, (Single T) equal or unequal of bore 110mm complete all as specified and as directed.
S & F in repair 75mm PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and as directed.
M&L for PCC 1:2:4 type B-0 using 12.5mm graded stone aggregate as in gola junction of wall and floor or for settings floor trap/ ‘P’ trap in position and PCC padding in floor complete (Work in foul condition as in shaft) all as specified and as directed.
M&L for rendering on fair faces of brick work or concrete surfaces 10mm thick in CM 1:4 finished even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering on fair faces of brick work or concrete surfaces 10 mm thick in CM 1:3 in celing finished even and smooth without using extra cement but using water proofing compound complete all as specified and as directed.
S&F anodised aluminium snap grid frame work for false ceiling complete all as specified and as directed.
S&F hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and as directed.
M&L for 4mm thick non-asbestos fiber cement building boards fixed or laid/ inserted to timber, GI/aluminium framework with screws complete all as specified and as directed.
M&L for preparation of newly plastered wall surfaces and applying two coats of oil emulsion distemper over a coat of alkali resistant primer complete all as specified and as directed.
M&L for preparation of newly plastered ceiling surfaces and applying two coats of oil emulsion distemper over a coat of alkali resistant primer complete all as specified and as directed.
Exacavation in trenches not exceeding 1.5 mtr in width and depth and getting out in hard/dense soil complete all as specified and as directed. Notes:- a) For all items involving excavation work contractor has to obtain prior approval from station HQ to avoid loss of other co existing utility services, in case of damage to any property he would be liable for its rectification. b)The excavation has to be done manually only.
All as per item no 78 above but depth exceeding 1.5 mtr complete all as specified and as directed.
Returning and filling in including levelling watering and well ramming into layers not exceeding 25 cm in hard/dense soil complete all as specified and as directed.
Removal of excavated soil to a distance not exceeding 50 mtrs and depositing at a level not exceeding 1.5 mtr from starting point complete all as specified and as directed.
Supply and spreading riddled earth for cushioning and covering of the UG cable in trenches complete all as specified and as directed.
Supply and lay PCC un reinforced cable cover of size 250 mmx150mmx40mm , class LV type I flat for cable protection complete all as specified and as directed. Note:- Contractor has to produce PCC cable cover test certificate from the manufacturer.
Material and labour for mass filling in foundation/coping/wall with PCC 1:3:6 using 40 mm graded aggregate type C2 as site requirement complete all as specified and directed by Engr in charge.
Supply and fix in replacement of route indicator for marking of HT/LT UG cable cable of any size with cast iron round plate of 100 mm dia suitably fitted on iron and embeded with PCC block complete all as specified and as directed.
Supply and fix in replacement of GI tubing light grade 40 mm nominal dia in trench/road/pole for cable protection complete all as specified and as directed.
Supply and laying LT cable in trench/fixing to walls/pipe/pole with proper saddles, lugs,glands XLPE insulated heavy duly galvanised steel strip armoured LT1100 volt grade with aluminium conductors of size 35 sqmm 3.5 core complete all as specified and as directed.
Supply and laying LT cable in trench/fixing to walls/pipe/pole with proper saddles, lugs,glands XLPE insulated heavy duly galvanised steel strip armoured LT1100 volt grade with aluminium conductors of size 6 sqmm 4 core complete all as specified and as directed.
Supply and fix LED flood light made out of pressure die cat aluminium housing with toughened glass of capacity not less than 15800 lumens , with system efficacy >130 Lumens/watt, IP 66 rated, with 10kv SPD on pole of height upto 11m using nesessary fixtures complete all as specified and directed by Engr-in-charge. Make:- Cat part No. BVP 192 LED 158 CW NBFG A1 GR PSU(Tango mini) of Philips make or equivalent in Crompton/Bajaj/Havells.
Supply and fix time switch panel made out of sheet metal enclosure having IP 54 degree of protection, with in built short circuit protection & digital timer - 01 No. complete with incomer MCB TPN of capacity 40A - 01No and contactor rating 32 A - 01 No. with proper canopy arrangement and should be fixed in using MS channel and PCC foundation with minimum 40Cm clearance from ground level complete all as specified and directed by Engr-in-charge. Make:- Havells( SAP code : IHXTS03060) or equivalent in L&T as approved by Engr-in-charge. Note:- Cost of excavation and necessary PCC work is deemed to be included in the quoted rate.
Supply and fix 9m steel tubular pole 410 SP 31 complete with CI base plate and final including foundation and coping complete all as specified and as directed.
Supply and fix MS channel, Cross arms bracings supports clamps and back plates fabricated from structural steel sections including nuts,bolts, washers, welding, bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all specified and directed by Engr-in-Charge.
Supply and fix in replacement of Copper cable flexible 2.5 Sqmm 3 core 230 Volts complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement weather proof street light junction boxes made out of thermo plastic consisting of 4 nos of connectors of capacity 40 amp 415v and 1no of SPN MCB rating 6 AMP 240 V with proper closing arrangement, elmax connector for neutral link including pole mounting clamp with nut bolts.The box should have two cable entry and should be able two accomodate two cables of size 25Sqmm with proper space between each phases complete all as specified and directed by Engineer-in-Charge.
Material and labour for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground(earth pit not less than 2.25 mtr below normal ground level) with top edge of the plate not less than 1.5 mtrs below normal GL, connected to and including galvanized earth lead Strip of size 32mmx6mm upto 7.5 m distance and connected by means of bolts,nuts,checknuts and washers of galvanized iron and including 15 mm dia medium grade GI pipe including excavation, earth work in any strata, charcoal, salt and pcc chamber, RCC 20 mm thick cover complete , testing and connecting up complete all as specified and directed by Engr-in-charge.
Material and labour for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground(earth pit not less than 2.25 mtr below normal ground level) with top edge of the plate not less than 1.5 mtrs below normal GL, connected to and including galvanized earth lead wire of size 4mm dia upto 7.5 m distance and connected by means of bolts,nuts, checknuts and washers of galvanized iron and including 15 mm dia medium grade GI pipe including excavation, earth work in any strata, charcoal, salt and pcc chamber, RCC 20 mm thick cover complete , testing and connecting up complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement of earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc. as using 4mm dia galvanised earth lead strip complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement of earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit /pipe or fixed to poles or any other indicated situation for loop earthing etc. as 32 x 6mm galvanised steel strip complete all as specified and as directed by Engr-in-charge.
M&L color code point wiring FRLS PVC insulated and unsheathed cable with 1.5 sqmm copper conductor single core multistandred 1100 volt grade conforming to IS 694 drawn through PVC conduit of suitable size, concealed / semi concealed/ open suitable size modular metal flush box fitted as per site requirement on ground with modular cover plate with frame (inner/ outer plate) for mounting switches or sockets regulators etc including FRLS 1.5 sqmm earth wire copper insulated wire connected to common earth dolly complete all as specified and as directed for the following:- Notes:- i. Necessary PVC rigid junction boxes for identifying junction as required on site/directed by Engineer in charge for point wiring work with PVC dummy plates shall deemed to be included in the quoted rate. ii. Same size wire shall be used for phase, neutral and earth conductor. iii. The wiring shall be done strictly by following proper colour coding using red , blue, yellow for phase, black for neutral and green for earth leads.
(a) One Light/ fan point controlled by one switch
(b) One 3 pin socket outlet outlet 6 Amps on the same board with other switches.
(c) 5 Amps socket point on independent board
Taking down carefully copper/ aluminium point wiring (light, fan and power socket etc) complete including fittings such as switches ceiling roses, pendent, regulators, sockets, MCB/ MCCB/ MCB DB/ earth plug and socket etc and making good matching to the existing colour to the disturbed surface complete all as specified and as directed. Note: - item No. 99.01(a) should be considered as taking down of point wiring since remaining all point wirings are providing additionally.
S&F in repair ceiling rose 3 terminals/PVC/polycarbonate isolated body complete all as specified and directed by Engineer in charge.
S&F in modular switch one way 6 Amps 1 module complete all as specified and directed by Engineer in charge.
S&F in modular socket 6 Amps 2/3 pin 2 module complete all as specified and directed by Engineer in charge.
S&F in modular socket 6 Amps/16 Amps 3 pin 2 module multipurpose complete all as specified and directed by Engineer in charge.
S&F in modular switch one way 16 Amps 1 way 1 module complete all as specified and directed by Engineer in charge.
S&F MCB SP 6-32A, 10 kA, C Curve in existing DB complete all as specified and directed by Engr-In-Charge.
M&L for sub main wiring using 2 runs of 2.5 Sq mm FR PVC insulated copper conductor 1100 Volts grade conforming to IS specification drawn through concealed/open conduit as per site requirement on ground along with 1 run of 2.5 sq mm PVC insulated copper conductor FR cable as earth lead connected to common earth dolly complete all as specified including taking down the unserviceable wiring. Note:- One run of PVC conduit, 3 runs of 2.5 sqmm PVC insulated copper conductor will be measured as one unit.
S&F in replacement wall mounted 20 W LED 4ft batten with colour temp 6000K having extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size from fitting to ceiling rose/connection terminals complete all as specified and directed by Engr-In-Charge. Make : Crompton Trimline cat No : CCS-103-20-40-SL-DP-NWH or equivalent in Havells/Phillips/Wipro/Jaquar.
S&F in replacement wall mounted 10 W LED 2ft batten with colour temp 6000K having surface & wall mounted LED batten with extruded aluminium for efficient heat dissipation with poly carbonate diffuser and integrated electronic driver including taking down of old fittings complete all as specified and directed by Engr-In-Charge. Make : Crompton Trim Line Cat Part No. CCS-103-20-40-SL-DP-NWH or equivalent in Havells/Phillips/Wipro/Jaquar.
S&F in replcement high efficiency 1x1 LED 18Watt recessed full lit luminaire with glare free unifirm illumination with longer life and less maintenance and including connecting up with three core twisted flexible copper conductor cable with suitable size from fitting to ceiling rose/connection terminals, luminous efficiency > 100/W, CCT 5500K, CRI>80, PF 0.95 complete all as specified and directed by Engr-In-Charge. Make : Crompton cat No. LCTLRNE-18-CDL or equivalent in Havells/Phillips/ Wipro/Jaquar.
Taking down and refix after completion of job works for exhaust fan of any sweep and make by disconnecting the electric connection, dismantling blades, down rods, etc for checking and replacing the unserviceable parts complete all as specified and as directed by Engr-In-Charge. Note :- spare parts shall be measured and paid seperately under relevant items.
M&L for painting exhaust fan of any sweep complete with one coat of synthetic enamel suitable paint by spraying after cleaning all dust etc complete all as specified and directed by Engr-In-Charge.
M&L for dismantling/opening the exhaust fan of 300mm sweep of metal body any make removing the old defective winding carefully cleaning the inner parts and rewinding with the same gauge super enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specifed and directed by Engr-In-Charge.
M&L for dismantling exhaust fan of any size and sweep removing old bearing and bushes of any size supply and fix with new bearing suitable size of make TATA/NBC/SKF and bushes including greasing reassembling and testing all as specified and directed by Engr-In-Charge.
M&L for removing old unserviceable capacitor, supply and fix new capacitor of 4 mfd suitable for exhaust fan of any size, make, model and testing all as specified and directed by Engr-In-Charge.
S&F exhaust fan louver up to 300mm dia including taking down of old louver and matching disturbed surfaces by proper painting all as specified and directed by Engr-In-Charge.
S&F exhaust fan blade 300 mm sweep complete all as specified and directed by Engr-In-Charge.
S&F Modular white cover plate with frame 3 Module as per site requirement complete all as specified and directed by Engr-In-Charge.
S&F PVC surface box 3 Module as per site requirement complete all as specified and directed by Engr-In-Charge.
Gates Infra Construction Co
KDR CONSTRUCTION
SANDR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .