Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.4 LAccepted-AOC SHREE NIVAS LIMDA LANE JAMNAGAR GUJARAT PIN 361001 | JAMNAGAR | GUJARAT | 361001 | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹34.0 L+₹53,466 (1.60%)Rejected-Finance 0 HISAR HISAR HARYANA 125004 UDYAM HR 06 0052049 | HISAR | HARYANA | 125004 | L2 | Rejected-Finance L2 | |
| 3 | L3₹34.3 L+₹88,463 (2.65%)Rejected-Finance AIR FORCE ROAD NEAR BRIDEES CORP KHELTIWADI RATIY N 9306 JAMNAGAR GUJARAT 361 006 | JAMNAGAR | JAMNAGAR | GUJARAT | 361006 | L3 | Rejected-Finance L3 | |
| 4 | L4₹34.4 L+₹99,031.50 (2.96%)Rejected-Finance 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | L4 | Rejected-Finance L4 | |
| 5 | L5₹34.7 L+₹1.3 L (3.92%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L5 | Rejected-Finance L5 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
5 Jul 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Lt Col Aman Bhardwaj
Military Engineer Service Garrison Engineer (AF) No.1 Air Force Station No.1 Jamnagar 361 003
REPAIR / MAINTENANCE OF INTERNAL BLDG ELECTRIFICATION AND MISC WORK AT OUTSIDE LOCATION OF AF-1 UNDER UNDER GE(AF) JAMNAGAR NO. 1
2024_MES_659913_1
8282/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Jamnagar
Please refer tender documents
6 documents required · 6 mandatory
₹500
GE AF Jamnagar No 1
₹70,000
Yes
12 Sept 2024
14 Jun 2024
6 Jul 2024
14 Jun 2024
5 Jul 2024
28 Jun 2024
Amount
Taking down carefully aluminium point wiring complete of any type (batten / surface conduit / concealed type) for light point, fan point, bell point socket point or power point complete with all fitting such as switches, sockets pendants, ceiling rose, round block etc complete and making good disturbed surfaces all as specified and directed. (Note :- Cutting chases for taking out concealed point wiring, if any, shall be measure and paid for under Item No 4 to 7 here in after)
Taking down carefully sub main wiring aluminium/copper conductor complete of any type and size (batten / surface conduit / concealed) and making good disturbed surfaces complete all as specified and directed. (Note :- Cutting chases for taking out concealed point wiring, if any, shall be measure and paid for separately)
Taking down carefully by unscrewing main switch boards/cut out boxes/MCB DBs, complete including sealing the cable end and making good disturbed surfaces of walls all as directed.
Material & Labour for point wiring for one light / Fan point controlled by one, one way switch complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable 1100 volts grade ISI marked, drawn through and including PVC concealed Conduit 20 mm dia , including all accessories like bend, tees, junction boxes etc. including 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable as a earth wire connected to common earth dolly, etc including pressed steel terminal box of suitable size and PVC cover sheet of suitable size; complete all as specified and directed. Note:- Quoted rates for this item are deemed to include for Cutting chases and refilling the same with cement sand mortar 1:4.
All as per item No 4 above but point wiring for one 5 Amps socket outlet on independent board controlled by one-way switch.
All as per item No 4 above but point wiring for one 5 Amps socket outlet on same board controlled by one-way switch.
All as per item No 4 above but wiring with 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable and 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable as earth wire connected to common earth dolly for 15 Amps multipurpose socket outlet on independent board, controlled with one way switch.
S&F Switch piano, flush type single pole, one way 5 Amp including connection complete.
S&F Socket outlet 3 pin, 6A, flush type including connection complete
S&F switch flush type 16 Amps, including connection complete.
S&F socket flush type 6/16 Amps, 2 in 1 multipurpose including connection complete.
S&F in repairs Switch piano, flush type single pole, one way 5 Amp including connection complete.
S&F in repairs Socket outlet 3 pin, 6A, flush type.
S&F in repairs switch flush type 16 Amps including connection complete.
S&F in repairs socket flush type 6/16 Amps, 2 in 1 multipurpose including connection complete.
M&L in repairs modular Switch, white polycarbonate body, single pole, one way 6 amp, 230 V, including connecting complete.
M & L in repairs modular socket white polycarbonate body, 6A- 230 V, 2/3 pin combined, including connecting complete.
M & L in repairs modular Switch, white polycarbonate body, 16A- 230 V, including connecting complete.
M & L in repairs modular socket, white polycarbonate body, 6A / 16A- 230 V, Multipurpose, indicator based including connecting complete.
M & L in repairs Ceiling rose 3 phase, 240 volts AC.
Supply and fix in repairs stepped type electronic fan regulator, white polycarbonate body, flush type, 230 V, including connecting complete.
Supply and fix in repairs modular stepped type electronic fan regulator, white polycarbonate body, flush type, 230 V, including connecting complete.
S&F in repairs energy efficient LED tube light fitting with built in LED & integral LED driver 20/22 watt, aluminium extruded channel (approximate length 1200 mm) housing & diffuser with all accessories, fixing arrangement internally pre-wired, fixed in position & connecting complete all as specified and directed.
S&F in repairs energy efficient LED tube light fitting with built in LED & integral LED driver 10 watt, aluminium extruded channel (approximate length 600 mm) housing & diffuser with all accessories, fixing arrangement internally pre-wired, fixed in position & connecting complete all as specified and directed.
Material & Labour for sub main wiring with 2 run single core multistranded copper conductor cable, of size 4 Sqmm, PVC insulated, unsheathed, fire retardant, low smoke (FRLS) drawn through and including PVC capping & casing not less than 25 mm wide with all necessary fitting and including one run single core multistranded copper conductor cable, of size 4 Sqmm, PVC insulated, unsheathed, fire retardant low smoke as earth wire, fixed on wall / ceiling complete.Note: 2 Runs of main cable and one run earth wire with capping & casing will be measured as one RM for payment.
S&F in repair energy efficient recessed mounted downlighter 18 watt LED luminaries suitable for square recessed with flat diffuser alongwith constant current electronic driver, UV resistance & polycarbonate cover complete.
S & F in repair metal clad plug & socket board Single pole and neutral enclosure with two pin and earth metal plug & socket complete with 20 Amp MCB SP, C curve complete all as specified.
S&F in repair Distribution board made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 4 way with 200 Amps rated copper bus bar neutral bar, earth bar IP 43 protection, single pole and neutral 230 volts, double door type, fixed flush to wall complete all as specified and directed.
S&F in repair Distribution board made out of sheet metal enclosure (CRCA sheet) dust and vermin proof TPN 4 way with 200 Amps rated copper bus bar neutral bar, earth bar IP 43 protection, single pole and neutral 230 volts, double door type, fixed flush to wall complete all as specified and directed.
S&F Distribution board made out of sheet metal enclosure (CRCA sheet) dust and vermin proof SPN 8 way with 200 Amps rated copper bus bar neutral bar, earth bar IP 43 protection, single pole and neutral 230 volts, double door type, fixed flush to wall complete all as specified and directed.
Supply and Fix in repair MCB single pole of 6 to 32 amp capacity C Curve, fixed in sheet metal board complete including connection complete all as specified and directed.
Supply and Fix in repair MCB single pole & neutral of 6 to 32 amp capacity, fixed in sheet metal board complete including connection complete all as specified and directed.
Supply and fix in repair MCB triple pole & neutral, 32 Amps, 415 volts with ‘C’ curve, fixed in sheet metal board complete including connecting.
Supply and fix in repair MCB triple pole & neutral, 63 Amps, 415 volts with ‘C’ curve, fixed in sheet metal board complete including connecting.
M&L for Taking out old unserviceable LT Panel board after disconnecing all incomging and outgoing connection complete all as specified as directed by Engr-in-charge
Supply,testing and commissioning indoor weather and vermin proof L.T.Panel board factory fabricated outdoor cubicle type totally enclosed made out of 3.15 mm thick sheet metal enclosure with angle iron frame of suitable size, CPRI approved, IP-42 for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel opening doors (covers) on two sides with handles, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber/wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor FRLS PVC insulated cables of adequate size, ........
duly painted with one coat of red oxide primer and two coats of synthetic enamel paint of gray or any other approved colour and bus bar rating 200Amp for 3 phase & neutral mounted on epoxy insulator-01 Set including provision of and connecting the following. (i) Incoming MCCB 4 pole , 415 Volts, 36 KA fixed type with thermal magentic relase of capacty 400 Amps - 01 Nos (ii) Outgoing MCCB 4 pole , 415 Volts, 36 KA fixed type with thermal magentic relase of capacty 200 Amps - 02Nos
(iii) Outgoing MCCB 4 pole , 415 Volts, 25 KA fixed type with thermal magentic relase of capacty 63 Amps - 02Nos
(iv) Outgoing MCB TPN 40 Amp 10 KA - 03
(v Multi functional Meter-1 No. (vi) Timer switch, -1 No (vii) LED Phase indicator lamps(RYB) - 1 set
Note : (a) Necessary busbar of suitable capacity and extension of studs for fixing of Incoming and outgoing cables as required as per site are deemed to be included in the quoted rate (b) PCC foundation concrete and coping shall be as per OEM recommendation.
Supply and installation, testing, commissioning, factory made, CPRI approved, outdoor type, LT Panel board of size 900mm 900mm x 450mm , confirming to IS 5039- with IP-54 protection, made out of 3.15 mm thick CRCA sheet , 415 Volt, 3 phase , 50 HZ supply mounted on and including MS angle section 60 x 60 x 6 mm frame with front and back openable, double door with provision of locking arrangement dust & vermin proof , gasket, TPN busbar shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proof, overall powder coated complete all as specified and directed & Consisting of the following equipments:-
(i) MCCB, 4 pole, 16 KA , 63 Amps -01 No ( Incoming) (ii) MCB, TPN, 10 KA, 32 Amps - 02 No (iii) Mounting arrangement for 2 MCB for future Expansions. (iv) Power Contactor MNX70 (v) Digital type/analog clock timer time switch (vi) Solid aluminium bus bar 200 Amp for 3 phase , 100 Amp for neutral
Supply and fix in repair Energy efficient recessed mounted 36 watt LED luminaries suitable for 600 x 600 mm grid ceiling along with flat diffuser along with constant current electronic driver, IP 65 Protection, UV resistant & polycarbonate cover all as specified and directed by Engg-in-charge.Make:- PLANO2X2PLR36WLED865S CG Cat No LCTLRP-24-FO-CDL or equivalent of make as specified.
Material and labour for provision in renewal of earthing complete with and including galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to and including galvanised mild steel strip 25 x 4 mm by means of bolts nuts check nuts and washer of galvanized steel, watering pipe of 20 mm bore galvanised iron medium grade and 40 mm bore galvanised iron light grade for earth strip protection including all excavation earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion.
Note:-Quoted rates shall be deemed to include for for provision of all the above new items including provision of earth strip with protection pipe of 7.5 M length.
Material and labour for provision in renewal of earthing complete with and including copper plate electrode 600 mm x 600 mm x 3 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to and including 20×3mm copper strip mm dia by means of bolts nuts check nuts and washer of galvanized steel, watering pipe of 20 mm bore, galvanised iron, light grade, and 15 mm bore galvanised iron light grade for earth wire protection including all excavation earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion.
Note:-Quoted rates shall be deemed to include for for provision of all the above new items including provision of earth strip with protection pipe of 7.5 M length.
M&L preparation of old painted surface of RCC street light pole 9 meter long above coping including cross arm etc and applying one coat of weather proof exterior emulsion paint as per the existing colour or as directed by Engineer-in-Charge and applying one coat of synthetic enamel paint for service bracket and MS clamps of light fittings including up to 1.2 mtrs alternate layers of tri-colour of black,yellow& white along with numbering of poles in white paint over the black base complete all as specified and directed.
M&L for painting of steel tubular pole of up 9 mtr height with two coats of synthetic enamel aluminium paint including cross arms, bracing , clamps GI pipe fittings etc and including up to 1.2 mtrs alternate layers of tri-colour of black,yellow& white along with numbering of poles in white paint over the black base complete all as specified and directed. complete after preparation of surface including writing pole Nos with white/black paint all as specified and directed.
Supply in repair MCCB 63 Amp, Four Pole, breaking capacity 16 KA, 415 V - 50 Hz, fixed in existing panel & connecting complete all as specified & directed.
Supply in repair MCCB 100 Amp, Four Pole, breaking capacity 16 KA, 415 V - 50 Hz, fixed in existing panel & connecting complete all as specified & directed.
Supply in repair MCCB 200 Amp, Four Pole, breaking capacity 35 KA, 415 V - 50 Hz, fixed in existing panel & connecting complete all as specified & directed.
Supply in repair MCCB 160 Amp, Four Pole, breaking capacity 36 KA, 415 V - 50 Hz, fixed in existing panel & connecting complete all as specified & directed .
Supply in repair MCCB 200 Amp, Four Pole, breaking capacity 35 KA, 415 V - 50 Hz, fixed in existing panel & connecting complete all as specified & directed.
Supply and fix in repair GI earth strip of size 32 x 6 mm fixed on wall over and including epoxy insulators and fixing screws etc for earth continuity conductors to test point terminal block complete all as directed.
Supply and fix in repair Copper earth strip of size 20 x 3 mm fixed on wall over and including epoxy insulators and fixing screws etc for earth continuity conductors to test point terminal block complete all as directed.
Taking down carefully street light fittings (LED type light) any make and capacity for repair and refixing in position after necessary repairing at same / different location, including provision of necessary T & P like ladder / Boom Veh, tools etc as required for taking down & refixing of Street light complete. Note:- Replacement of defective spare part for repairing of fitting will be measured & paid separately as supply & fix in repair.
Supply only driver suitable for 150-200watt LED Flood light fitting.
Supply only driver suitable for 90-110watt LED Flood/street light fitting.
Supply only driver suitable for 60-72watt LED Flood/street light fitting.
S&F in repair Power Contactor 3 pole 32 amps, Aux contacts, 415V, 50Hz., fixed in position & connecting complete.Make: L&T type MNX or equivalent of specified makes
S&F in repair Analog type clock timer switch to set street light ON / OFF timing. Make: L&T / Legrand / Schneider
S&F in repair LED type building security light of capacity 35/36 watt white light with driver, having luminaries Efficiency not less than 100 lm / Watt, fixed in Pressure Die Cast Aluminum housing, & glass cover, Ingress protection of IP 66, including all necessary fitting & fixture,& connecting complete.
S&F in repair LED flood Light fitting 150 watt, system efficiency not less than 100 lumen / watt, IP65 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws fixed on existing bracket & connecting, including taking down old light fitting of any description complete all as directed.
S&F in repair LED flood Light fitting 200 watt, system efficiency not less than 100 lumen / watt, IP65 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws fixed on existing bracket & connecting, including taking down old light fitting of any description complete all as directed.
S&F in repairs LED Street Light fitting 70-72 watt, system efficiency not less than 100 lumen / watt, IP65 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws, fixed on existing bracket & connecting complete all as directed complete.
S&F street light bracket fabricated from 40 mm bore galvanised iron tubing light grade, 1.2 metre long, bent to shape fixed on pole / bldg including mild steel flat iron clamps, nuts, bolts etc including taking down old bracket from existing position complete.
Supply & fix in repairs weather proof, PVC insulated, FR PVC sheathed, cable, with multistranded copper conductor of size 2.5 Sqmm, 2 core, fixed from Junction box to street light fittings including taking down old cable.
S&F in repair LED Aviation obstruction light fitting die cast aluminium alloy housing, heat resistant, clear thick glass and accessories with LED chip & driver, fixed in position & connecting complete. Make Bajaj Cat No BGAV 302 LED or equivalent of specified makes.
Supply and fix in replacement of LED Bollard garden light fitting with base plate and necessary foundation and connected electric connections and PCC work complete and IP 65 / IK 10 bollard Make Havells BAMBOOBLS8WLED857PSYMTOPC or equivalent of specified makes.
Supply and fix in replacement of LED Post-Top lantern 40watt, energy saving, environmental friendly, long life aesthtically designed with symmentrical light distribution, spun aluminium landscape luminaire with high power LEDs as suitable for pole size and making arrangements ,pcc work , electric connections complete Make:- Crompton Cat No: LPTO-40-CDL or equivalent of specified makes.
S&F in repair 20mm dia PVC conduit ISI marked heavy duty fixed complete to walls/on pole with mild steel clamp nuts and bolt complete
S&F in repair Sheet moulding compound (SMC) junction box of size 250 mm x 200 mm x 150mm, comprising three phase aluminium bus bar and one No MCB SP, 06 Amps C type, fixed on pole with mild steel clamps, nuts and bolts complete.
Supply & laying 40 mm bore mild steel galvanised iron tubing light grade for protection of cable / earth continuity conductor etc, fixed to poles / wall with clamp nut bolt etc / laid on roof or laid on floors, road, crossing or ducts etc, including taking down old tubing complete all as specified and directed.
Supply & laying 50 mm bore mild steel galvanised iron tubing light grade for protection of cable / earth continuity conductor etc, fixed to poles / wall with clamp nut bolt etc / laid on roof or laid on floors, road, crossing or ducts etc, including taking down old tubing complete all as specified and directed.
Supply & laying 80 mm bore mild steel galvanised iron tubing light grade for protection of cable / earth continuity conductor etc, fixed to poles / wall with clamp nut bolt etc / laid on roof or laid on floors, road, crossing or ducts etc, including taking down old tubing complete all as specified and directed.
Excavation in trenches not exc 1.5m wide and n.exc 1.5m in depth for foundation / fixing pole / laying cable and pipe line etc or for man hole etc not exc 10 sqm on plan and getting out in soft / loose soil all as specified.
Returning filling in including spreading levelling, watering and well ramming in layers not exc 25 cm thick using suitable excavated soil all as directed
Removing excavated soil to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5m above the starting point.
M&L for providing dry river sand as in sand cushioning below and above cable thickness as specified in SSR to under ground cable including punning down of sand in layer all as specified and directed by Engg-in-Charge.Note: for measurement purpose punned thickness of sand will be considered.
Taking out old PCC cable cover of any size / any type from trenches and relaying all as specified and directed
Supply & laying ISI marked & conforming to IS - 5820 - 1970 unreinforced precast concrete cable cover Class LV, flat of size 250 mm X 150 mm X 40 mm in trenches as protection to LT UG cable all as specified.
Taking out Old unserviceable LT aluminium conductor UG cable of size 3.5/4 core upto 50 sqmm all as specified and directed.
Taking out Old unserviceable LT aluminium conductor UG cable of size 3.5/4 core from 70 to 120 sqmm Sqmm all as specified and directed.
Supply & lay UG XLPE insulated armourned heavy duty electric cable with Aluminium conductor 1100 V grade laid in trenches / passing through GI tubing / on pole / on wall etc. all as directed & specified of following sizes :-
16 Sqmm 4 core
25 Sqmm 3.5 core
95 Sqmm 3.5 core
120 Sqmm 3.5 core
Note :- (i) Earthwork, sand cushion, cable cover will be measured and paid separately under respective items of this Schedule. (ii) Straight through joint will be measured and paid separately.
Supply jointing connecting and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 3.5 core, 50 to 95 Sqmm all as specified and as directed.
Supply jointing connecting and testing, straight through joint, epoxy based complete with jointing material and all standard accessories suitable for XLPE insulated armoured aluminium conductor cable, LT 1100 Volts, aluminium conductor of 3.5 core, 120 to 240 Sqmm all as specified and as directed.
Taking down carefully ceiling fan / exhaust fan / cabin fan / wall mounted fan by disconnecting electric connection for repairing such as rewinding, replacement of defective spare part, over hauling and painting etc as required and re-fixing in the same position after carry out the repairs works, testing and connecting complete all as directed by Engr-in-Charge. Note:- (i) Repairing such as rewinding, replacement of defective spare part, connecting wire etc will be measured & paid separately as supply & fix in repair (ii) Over hauling and painting will be measured & paid separately. (iii) After repair / replacement of worn-out parts, the fan will be tested to the entire satisfaction of Engineer-In-Charge and in case of failure of test, the same shall be repaired at contractor's cost.
M & L for rewinding of ceiling fan 1200/1400 mm sweep of any make by dismantling the ceiling fan, removing the burnt winding, cleaning slot, replacement of defective nut bolts washer etc and rewinding with using appropriate size of super enameled copper winding wire thermal class-E, including varnishing and reassembling and testing complete all as directed by the Engineer-in-Charge
All as item No 2 above but exhaust fan 300/450 mm sweep.
Supply and fix in repair ball bearing of any size of ceiling fan of 1200 mm / 1400 mm sweep complete.
Supply and fix in repair capacitor 2.5 MFD AC 230 Volt 50 HZ, of ceiling fans.
Supply and fix in repair PVC insulated, PVC sheathed three core copper conductor cable multi stranded of size 0.5 Sqmm for connecting of fan from ceiling rose complete.
RAJ ENTERPRISE
SohanandCompany
SURESH ELECTRICALS
DWARKADHISH ENTERPRISE
M/S Rajendra Constructions
jagdish machinery stores
M/s SK Traders
High Tech Consruction
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .