| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.7 CrAccepted-AOC | ₹35.7 Cr Quoted ₹35.6 Cr | L1 | Accepted-AOC LOWEST |
| 2 | L2₹35.6 CrRejected-Finance | ₹35.6 Cr | L2 | Rejected-Finance NOT LOWEST |
| 3 | L3₹36.3 CrRejected-Finance | ₹36.3 Cr | L3 | Rejected-Finance NOT LOWEST |
| 4 | L4₹36.6 CrRejected-Finance | ₹36.6 Cr | L4 | Rejected-Finance NOT LOWEST |
| 5 | L5₹37.9 CrRejected-Finance | ₹37.9 Cr | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹38.1 Cr
EMD Value
₹15 L
Closing Date
30 Nov 2020, 6:00 pmClosed
CE R AND D SECUNDERABAD
CE R AND D PICKET SECUNDERABAD 500 003
PROVISION OF SINGLE LIVING ACCOMATION FOR DSC AT VISAKHAPATNAM
2020_MES_353937_2
CERD/VIZ/TOKEN/56 OF 2019-2020
Open Tender
Civil Works
730 days
VISAKHAPATNAM
AS PER NIT
8 documents required · 8 mandatory
₹3,000
GE I NYC VISAKHAPATNAM
₹15 L
Yes
4 Feb 2021
6 Nov 2020
7 Dec 2020
6 Nov 2020
30 Nov 2020
21 Nov 2020
7 Nov 2020 - 15 Nov 2020
Amount
Schedule 'A' Part - I (BUILDINGS AND STRUCTURES) This Schedule (contains under mentioned Sl. item No.1.01 to 1.15) is not prepriced by MES and the prepriced rate indicated in Col - 5 as `0.00 indicates this fact only.The tenderer is required to quote their rates in Column 6.
Lumpsum price worked out by the contractor for "Construction of block of Single living accommodation, Mess and Cook House for Havs (32 Nos) & OR's (460 Nos) and Storage accn including Parking area at Ground floor in Eight floors (G+7), above pile cap", complete all as shown on drawings and as specified.
Lumpsum price worked out by the contractor for "Construction of block of Single living acommodation for JCO's (40 Nos), Mess and Club club including Parking area at Ground floor in Six floors (G+5), above pile cap", complete all as shown on drawings and as specified. NOTE:- (for Sl. Item No. 1.01 and 1.02 here-in-above): Pile foundation upto pile cap shall be measured and paid seperately under respective Schedule of this BOQ. The rate quoted shall deemed to be include the cost of item above pile cap only i.e., except pile foundation and pile cap.
Lumpsum price worked out by the contractor for "Construction of block of Guard Room", complete all as shown on drawings and as specified.
Lumpsum price worked out by the contractor for "Construction of block of Religious Institute", complete all as shown on drawings and as specified.
Lumpsum price worked out by the contractor for "Construction of block of Sub Station", complete all as shown on drawings and as specified.
Lumpsum price worked out by the contractor for "Construction of block of Pump house", complete all as shown on drawings and as specified.
Lumpsum price worked out by the contractor for "Construction of block of Parking Shed (for Fire tender and 06 Nos vehicles)", complete all as shown on drawings and as specified.
Lumpsum price worked out by the contractor for "Construction of Dhobi Ghat with 3 No Stones, complete all as shown on drawing No. TD/427/2012 sheet 1/1" and as specified.
Lumpsum price worked out by the contractor for "Construction of Alarm Post complete all as shown on drawing No. CERD/TD/477/2020 sheet 1/1" and as specified.
Lumpsum price worked out by the contractor for "Construction of Flag Staff complete all as shown on drawing No. CERD/TD/478/2020 sheet 1/1" and as specified.
Lumpsum price worked out by the contractor for "Construction of Sentry Post complete all as shown on drawing No. TD/355/2003 sheet 1/2 & 2/2" and as specified.
Lumpsum price worked out by the contractor for "Construction of Incinerator complete all as shown on drawing No. TD/146/82 sheet 1/1" and as specified.
Lumpsum price worked out by the contractor for "Construction of Garbage Bins complete all as shown on drawing No. TD/360/2004 sheet 1/1" and as specified.
Lumpsum price worked out by the contractor for "Construction of Semi UG sump of capacity 1 Lakh gallon complete all as shown on drawing Nos. TD/362/04 sheet 1/2 & 2/2" and as specified.
Lumpsum price worked out by the contractor for "Construction of Septic tank along with filter bed for 750 users, complete all as shown on drawing Nos TD/AR/33/95 sheet Nos 1/3 to 3/3" and as specified.
Lump sum price worked out by the Contractor for "EXCAVATION, EARTHWORK, SITE CLEARANCE AND DEMOLITION” as listed in Schedule ‘A’ Part - II representing _______ % ________________ percent Above / Below the lumpsum price of `43,29,316.31 inserted by the MES in Schedule ‘A’ Part - II
Lump sum price worked out by the Contractor for “ROAD / CULVERT / FOOTPATH” as listed in Schedule ‘A’ Part - III representing _______ % ______________ percent Above / Below the lump sum price of `90,32,422.18 inserted by the MES in Schedule ‘A’ Part - III
Lump sum price worked out by the Contractor for “SEWAGE DISPOSAL” as listed in Schedule ‘A’ Part - IV representing __________ % ____________ percent Above / Below the lump sum price of `7,53,000.25 inserted by the MES in Schedule ‘A’ Part - IV
Lump sum price worked out by the Contractor for "AREA DRAINAGE” as listed in Schedule ‘A’ Part - V representing _______ % __________________ percent Above / Below the lump sum price of `32,04,411.62 inserted by the MES in Schedule ‘A’ Part - V
Lump sum price worked out by the Contractor for “SECURITY FENCING AND GATE” as listed in Schedule ‘A’ Part - VI representing _______ % _________________ percent Above / Below the lump sum price of `2,03,742.19 inserted by the MES in Schedule ‘A’ Part - VI
Lump sum price worked out by the Contractor for “RAIN WATER HARVESTING” as listed in Schedule ‘A’ Part - VII representing _______ % _________________ percent Above / Below the lump sum price of `13,855.19 inserted by the MES in Schedule ‘A’ Part - VII
Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part - VIII representing ______ % _________________ percent Above / Below the lump sum price of `8,30,340.00 inserted by the MES in Schedule ‘A’ Part - VIII
Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part - IX representing ______ % _________________ percent Above / Below the lump sum price of `4,26,937.80 inserted by the MES in Schedule ‘A’ Part - IX
Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part - X representing ______ % _________________ percent Above / Below the lump sum price of `36,02,071.98 inserted by the MES in Schedule ‘A’ Part - X
Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part - XI representing ______ % _________________ percent Above / Below the lump sum price of `7,10,786.73 inserted by the MES in Schedule ‘A’ Part - XI
Lump sum price worked out by the Contractor for “STANDBY DG SET AND LIFTS” as listed in Schedule ‘A’ Part - XII representing ______ % _________________ percent Above / Below the lump sum price of `20,231.00 inserted by the MES in Schedule ‘A’ Part - XII
Lump sum price worked out by the Contractor for “FIRE FIGHTING SYSTEM” as listed in Schedule ‘A’ Part - XIII representing ______ % _________________ percent Above / Below the lump sum price of `15,86,950.90 inserted by the MES in Schedule ‘A’ Part - XIII
Lump sum price worked out by the Contractor for “HOT WATER SUPPLY” as listed in Schedule ‘A’ Part - XIV representing ______ % _________________ percent Above / Below the lump sum price of `1,61,000.00 inserted by the MES in Schedule ‘A’ Part - XIV
Lump sum price worked out by the Contractor for “LIGHTENING PROTECTION” as listed in Schedule ‘A’ Part - XV representing ______ % _________________ percent Above / Below the lump sum price of `1,38,776.80 inserted by the MES in Schedule ‘A’ Part - XV
Lump sum price worked out by the Contractor for “PILE FOUNDATIONS AND PILE CAP” as listed in Schedule ‘A’ Part - XVI representing ______ % _________________ percent Above / Below the lump sum price of `98,67,590.61 inserted by the MES in Schedule ‘A’ Part - XVI
Total amount of PROVISIONAL SUM of `12,00,000.00 in respect of the following: (a) Basket Ball Court (b) Badminton Court (c) Volley Ball Court (d) Apron for Parking (66.42 sq.m) (e) PCC Hardstanding (40 sq.m) Note: Above Provisional Sum cost includes Earthwork Excavation, Excavation in Post Holes, Removal of excavated earth, levelling the surfaces and site clearance
Schedule 'A' Part - XVII This Schedule is not prepriced by MES and the prepriced rate indicated in Col - 5 as `0.00 indicates this fact only.The tenderer is required to quote their rates in Column 6. This Schedule constitutes Sl. Item No. 19 to 133
HDPE pipe (perforated) 150mm dia including fittings and binding of plastic netting at top and around the pipe, complete all as specified and directed.
Drilling / boring holes 200mm dia for inserting the HDPE perforated pipe (all as per Sl. Item No. 19.00 here-in-before) upto depth as directed in soft / loose soil, with and including provision of disposal of spoil to a distance upto 50metre, complete all as specified and directed.
Concertina coil, 1050mm dia (streched to 4metre length) consisting of spirals with sharp edged tape crimped to a steel wire duly galvanized with scrapper barb having 51 spirals with 125 chips, complete all as specified and directed.
EXTERNAL ELECTRIFICATION Supply, testing & commissioning of 11 KV Outdoor type RMU non extensible IP54 SCADA compatable floor mounted with internal copper bus bars, consisting of fixed motorized VCB-02 nos as incomer [incl Line PT] and fixed type Motorised Vacuum Circuit Breakers-01 Nos as outgoing, 03 Nos Motorised LBS as Outgoings as along with air insulated metering module. All live parts, bus bars of RMU should be enclosed in tank to avoid multiple interconnections & sealed for life robotically for three sides and one side manual welded non magnetic / non ferrite / stainless steel tank Grade 304 of minimum 2mm thick having IP67 degree of protection filled with SF6 gas as insulation with leakage rate less than 0.1% per year tested as per IEC 62271-200. The unit shall have front cable entry for ease of installation. RMU should complete with all accessories such as terminal boots, VPIS, cable supports, all front cable terminations, mechanical indications ON/OFF, Manometer as per with IEC standards 62271-200, 60056, 60129, 60265, 60298, 60420, 60529 and 60694. Altitude of installation upto 1000m as per IEC 60120. Bushings bolted type as per OEM design. The unit shall include the following with all necessary standard fitting required at site. RMU shall be tested for an internal arc fault of 21kA for 1 sec. for tank holding the HV components & cable box, complete all as specified and directed..
Sl. item No. 22.00 Contd... LBS FEEDER: 3 Nos 630A Load Break Switch module for making of fault current alongwith SCADA Compatable Earth Swicth of full making capacity with Motorization kit, Short time withstand current - 21KA / 3 sec · Making Capacity - 52.5KA · Auxiliary contacts - 1NO + 1NC · Power frequency withstand voltage - 38KV, Impulse withstand voltage - 95KV ,· Nominal operating gas pressure - 1.4 Bar abs, Front cover mechanism - IP2X· Cable, RMU should be tested for an internal arc fault of 21kA for 1 sec. for tank holding the HV components & cable box. covers - 3X RMU should be tested for an internal arc fault of 21kA for 1 sec for tank holding the HV components & cable box. Snap action mechanism for manual operation. Cable box for front termination of the cable suitable 11 KV XLPE cable right angle boots (push on type). Suitable cable bushings for front only cable terminations. Arc proof cable covers with self Interlocking mechanism with earth switch VCB MODULE: 3 Nos 630A VCB module for making & breaking of fault current alongwith earth swicth of full making capacity. Vacuum circuit breaker shall be SCADA Compatable having spring stored mechanism suitable for manual / motorized operation-24VDC.
Sl. item No. 22.00 Contd... Opening & Closing coils - 24VDC. Three position disconnector / earthing switch downstream vacuum circuit-breaker. Three position single spring mechanism for disconnector / earthing switch. “Live Cable” LED Indicators through Capacitor Voltage Dividers mounted on the bushings. Short time breaking current - 21KA/ 3 sec making capacity - 52.5KA. Auxiliary contacts - 6NO + 6NC. Power frequency withstand voltage - 38KV. Impulse withstand voltage - 95KV. Nominal operating gas pressure - 1.4 Bar abs. Front cover mechanism - IP2X. Cable covers - 3X. 3O/C + 1E/F self powered numerical protection relay with Low and High set for Over current and Earth Fault. RMU tank & Cable Box shall be tested for an internal arc fault of 21KA for 1 sec, No of electrical operating cycles shall be 2000 cycles and short circuit cycles shall be 50. Resin cast ring core protection. CT on cables 100-50/1 A, 5P10, 2.5 VA - 3 Nos. Resin cast ring core Metering CT on cables 100/1 A, Cl-1.0, 2.5 VA - 3 Nos. Mechanical ON / OFF / EARTH / Spring charge indication. Cable boxes should be Arc Proof interlocked with respective Earthing Switches. Line Connected Air Insulated Metering Module for Incomer VCB Feeder.
Sl. item No. 22.00 Contd... Three Phase PTs - 11kV/V3/110/V3, Cl-1.0, 50VA-1 No. Space Heater with thermostat, Terminal Blocks, 4 x UV / OV Protection Relays. Digital Multi Function Meter, Cl-1.0, 50VA of Make: EL measure / Conzerv / Rishab including inbuilt battery along with battery charger and maintenance free batteries of capacity not less than 20 AH to give backup up to 05 hours with 10 open / close operations. Make: ABB/SIEMENS / SCHNEIDER Note: (i) Auxiliary relays for WTI & Trip, outgoing VCB module 4 x Lockout relays (86) / Transformer digital card for all VCBs Outgoing Feeder, Dummy module for accomodating the necessary Auxiliaries as per site requirement. (ii) Pre-despatch inspection at factory premises to be carried out by rep of accepting officer and the cost to be borne by contractor. (iii) Necessary Civil work like plinth, fencing etc., deemed to be included in the unit rate quoted.
Supplying, installing, testing and commissioning indoor distribution panel board suitable for 3 phase, 4 wire, 415 volts, 50 Hz and CPRI approved, factory made in an approved factory having seven tank treatment process for powder coating provided and FRP coating on outer surface of the complete panel with suitable gasket to make it dust / vermin proof & general construction confirming to IS:8623 / 93, compartmentalized cubical indoor type with compartments for each out going and incoming feeders (LxHxD) made of 2mm thick CRCA sheet painted with one coat of epoxy based powder coating with support of suitable angle iron, angle iron bottom legs frame with double hinged front openable shutters of each feeder control unit with locking arrangement in front, PVC sleeved electrolyte aluminium bus bar RYBN with 1400 Amps capacity for each phases and half neutral fixed on suitable insulator all housed in suitable bus bar chamber along with provision of necessary cable entry / exit boxes fixed on suitable PCC foundations and comprising (with and including provision) of following switch gear, complete all as specified and directed: (a) 1000 Amps 4P, 50KA ACB 4P Icu = Ics = Icw (1 Sec) electrical drawout type - 01 No (I/C) (b) 630 Amps 4P, 50KA ACB 4P electrical drawout type - 01 No (O/G for ORs)
Supply, installed, test and commissioning of automatic power factor (APFC) control panel 200 KVAR, having 12 banks, panel fabricated with 2mm thick CRCA sheet with angle iron frame of 40x40x6mm, duly powder coated painted in and including the following:- (a) Aluminium bus bar 400 Amps, supported with suitable size porcelin stand lock with suitable six brass nut, bolts and washers with heat shrinkable colour coded PVC sleeving for 3 phase and neutral-01 set (b) MCCB, 4 pole, 315 Amps 35 KA, 415 Volts, 50 Hz - 1 No. (I / C) (c) APFC Relay with auto / Manual Mode 16 ways - 01 No. (d) Capacitor MPP-H 3 (phase, 415 volts, 50 Hz, 150 KVAR ie (5x3 + 10x4 + 15x3 + 25x2 + 50 fixed (Total 200 KVAR) (e) MCB class "D" of suitable rating as control for various capacitors with heavy duty contractor of suitable rating for capacitor switching. (f) Bank ON / OFF indication lamps. (g) Cooling fan, SP 230 volts - 01 No / as required.
Loop-in-loop out boxes from the street light poles, supply and fix, FRP Junction boxes / Loop-in-loop out boxes inclusive of 4 pole connector, 50 Amp bus connector 04 way, 6 Amp MCB for control including necessary internal wiring complete all as specified and directed.
Sub main wiring complete with two runs of single core 1.5 sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawn through and including provision of concealed non-metallic rigid PVC conduit of size not less than 20mm dia and its accessories and connecting terminal ends to DB's including providing one run of 1.5 sq.mm PVC insulated unsheathed multistranded FRLS grade copper cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed. NOTE:- (i) Two runs of 1.5 sq.mm copper conductor, one run of 1.5 sq.mm copper earth continuity conductor and one run of PVC conduit shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly.
Street Light Fitting of >12000 lumen output and colour temperature not less than 5700K, with not more than 120 Watts power consumption LED Road lighting luminaire with high power LED, unique peanut lens with choise of optics to ensure uniform distribution of lighting, maintenance free system, IP-66 including with pipe mounting arrangement for end mounting on 40 / 50mm dia pipe including provsion of GI pipe bracket for 40 / 50mm dia, light grade, bent to shape as directed, 1.5m long with two sets of clamp, made out of flat iron 20x3mm, bolts, nuts and washers with two coats of aluminum paint over a coat of primer to steel surfaces, connecting electrically with PVC multistranded copper cable of suitable size and taking down existing street light fittings from poles, complete all as specified and directed. MAKE: Cat No.LSRT01S120XC of Jaquar or techno-commercially equvalant model in BAJAJ / Crompton Greaves / Philips
Supply & Fix, Flood light fitting of colour temperature not less than 6000K, Lumen output>20000 Lumens with not more than 200 Watts power consumption LED road lighting luminaire with high power LED, unique peanut lens with choise of optics to ensure uniform distribution of lighting, maintenance free system, IP-66 including with bracket mounting arrangement on pole with two sets of clamp, made out of flat iron 25x4mm, bolts, nuts and washers with two coats of aluminum paint over a coat of primer to steel surfaces, connecting electrically with PVC multistranded copper cable of suitable size and taking down existing street light fittings from poles complete all as specified and directed. NOTE:- Rate quoted shall be deemed to include the cost of necessary Elevators / Crane / Genie / VMTL / JLG for fixing the light fittings. MAKE: Cat No.LFLD02S200XC of Jaquar or techno-commercially equvalant model in BAJAJ / Crompton Greaves / Philips
Earthing complete with GI earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground vertically to a depth of not less than 2.25m deep below ground level with the top edge of earth plate at a depth of not less than 1.5m below ground level connected to GI earth strip 32mm x 6mm by means of bolts, nuts, washers of galvanised iron or steel, GI earth strip shall be protected by 40mm dia GI pipe 'medium grade', watering pipe 20mm dia GI pipe 'light grade', GI wire meshed funnel, alternate layer of charcoal and salt on all side to earth plate upto a thickness of 150mm, filling of black cotton soil in earth pit upto GL and connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber, 40mm thick RCC cover (1:2:4) mix with 6mm dia nominal reinforcement @ 150mm c/c both ways etc complete all as shown in electrical plate No.3 connected to earthing test point, including testing on completion, complete all as speciifed and as directed. NOTE:- (a) Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50metre, PCC pit, funnel and RCC cover plate. (b) Earth continuity conductor beyond 7.5metre and GI tubing medium grade 40mm dia shall be measured and paid under respective item of this Schedule.
Earthing complete with GI earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground vertically to a depth of not less than 2.25m deep below ground level with the top edge of earth plate at a depth of not less than 1.5m below ground level connected to GI earth wire 4mm dia by means of bolts, nuts, washers of galvanised iron or steel, GI earth wire shall be protected by 15mm dia GI pipe 'medium grade', watering pipe 20mm dia GI pipe 'light grade', GI wire meshed funnel, alternate layer of charcoal and salt on all side to earth plate upto a thickness of 150mm, filling of black cotton soil in earth pit upto GL and connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber, 40mm thick RCC cover (1:2:4) mix with 6mm dia nominal reinforcement @ 150mm c/c both ways etc complete all as shown in electrical plate No.3 connected to earthing test point, including testing on completion, complete all as speciifed and as directed. NOTE:- (a) Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50metre, PCC pit, funnel and RCC cover plate. (b) Earth continuity conductor beyond 7.5metreand GI tubing medium grade 20mm dia shall be measured and paid under respective item of this Schedule.
Boring holes under Roads / Railway Track / Hard standing by trenchless technology using ultra sounding technique, suitable for and including provision of 150mm dia HDPE pipe for 0.4 MPa working pressure, for laying HT 11KV cables complete all as specified and directed.
EXTERNAL WATER SUPPLY DI (Ductile Iron), 200mm bore, with flanged ends conforming to IS 8329-2000 in standard maximum length of K-9 class, with cement mortar lining as per IS-6452 not less than 6mm thick on the inside and metallic zinc coating as per Annex 'A' of IS-8329 including finishing layer of bituminous coating as per Annex 'C' of IS-8329 on both sides, alongwith rubber gasket for push-on-joints of mechnical joints as per IS-5382 and rubber gaskets for flanged joins as per IS-638, made of styrene Butadine rubber / Ethylene Propylene Dine Monomer conforming to IS-5382, duly ISI marked or as per site requirment, laid in trenches / pass under the road etc., including carrying out testing against leakage, complete all as specified and directed.
DI (Ductile Iron), 150mm bore, with flanged ends conforming to IS 8329-2000 in standard maximum length of K-9 class, with cement mortar lining as per IS-6452 not less than 6mm thick on the inside and metallic zinc coating as per Annex 'A' of IS-8329 including finishing layer of bituminous coating as per Annex 'C' of IS-8329 on both sides, alongwith rubber gasket for push-on-joints of mechnical joints as per IS-5382 and rubber gaskets for flanged joins as per IS-638, made of styrene Butadine rubber / Ethylene Propylene Dine Monomer conforming to IS-5382, duly ISI marked or as per site requirment, laid in trenches / pass under the road etc., including carrying out testing against leakage, complete all as specified and directed.
DI (Ductile Iron), 100mm bore, with flanged ends conforming to IS 8329-2000 in standard maximum length of K-9 class, with cement mortar lining as per IS-6452 not less than 6mm thick on the inside and metallic zinc coating as per Annex 'A' of IS-8329 including finishing layer of bituminous coating as per Annex 'C' of IS-8329 on both sides, alongwith rubber gasket for push-on-joints of mechnical joints as per IS-5382 and rubber gaskets for flanged joins as per IS-638, made of styrene Butadine rubber / Ethylene Propylene Dine Monomer conforming to IS-5382, duly ISI marked or as per site requirment, laid in trenches / pass under the road etc., including carrying out testing against leakage, complete all as specified and directed.
DI pipe specials of bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) tee pieces single branch. "Y" junction, double branch, cross (all sockets or socket and spigot or flanged) collars, caps and plugs, complete all as specified and directed.
200 mm dia
150 mm dia
100 mm dia
Foot valve of 200mm dia CI, flange end, swing type, conforming to IS: 4038, of pressure rating PN 0.2 with fitting accessories, complete all as specified and directed.
Supply, erecting, testing and commissioning of horizontal split casing pumpset with energy efficiency (IE 1) TEFC squirrel cage induction motor of capacity 55KW/70 HP, 1450RPM, 3 phase 415 Volts, 50 Hz and pump having discharge capacity of 2280 LPM at head of 70 Mtrs with Bronze impeller, stainless steel shaft, gland packing including Corrocoat inside the pump with MS fabricated Base Frame, suitable Coupling for Pump and Motor complete including PCC base foundation, complete all as specified and directed.
Supply, install, testing & commissioning of horizontal open well submersible pump for priming purpose of capcity 2.0HP, 415 volts, 50Hz, complete including FASD starter and copper control cable of 3 core 4.0 sq.mm cable of 30metre length, complete all as specified and directed.
Electric copper conductor cable of 3 core 25 sq.mm with necessary flat / rounded PVC insulated unsheathed multistranded copper conductor 1100 Volts grade on surface of wall / roof / floor through GI / DWC HDPE pipe protection with proper clamps and connecting to Startor and Motor with proper copper lugs, complete all as specified and directed.
Supplying, installing, testing and commissioning indoor cubical starter control panel suitable for 3 phase, 4 wire, 415 volts, 50 Hz and CPRI approved, factory made in an approved factory having seven tank treatment process for powder coating provided and FRP coating on outer surface of the complete panel with suitable gasket to make it dust / vermin proof & general construction confirming to IS:8623 / 93, compartmentalized cubical indoor type with compartments for each out going and incoming feeders of size 2000 x 1500 x 600mm (L x H x D) made of 2 mm thick CRCA sheet powder coated paintg with support of angle iron of 90 x 90 x 8 mm angle iron bottom legs frame with double hinged front openable shutters of each feeder control unit with locking arrangement in front, PVC sleeved electrolyte copper bus bar with tin coating of 600 Amps capacity for each phases and neutral fixed on suitable insulator all housed in suitable bus bar chamber along with provision of necessary cable entry / exit boxes fixed on suitable and including provision of PCC foundations and following items, complete all as specified and directed:-
Sl. item No. 42.00 Contd... (a) 400 Amps 4P, 36KA MCCB - 01 No (b) Spreader Links for 400A 4P - 04 Nos (c) 200 Amp TP, 16KA MCCB & ROH - 02 Nos (d) 63 Amp TP, 16KA MCCB & ROH - 02 Nos (e) Multifunction Meter - 01 No (f) R Y B Phase Indication Lamps - 03 Nos (g) CTs 1250/5A, 15VA, CL-1 - 03 Nos (h) 6A SP Control MCB - 03 Nos (j) Panel internal control wiring using PVC copper flexible in duct of suitable size - 01 Job (k) 70 HP FASD Starter and connected accessories - 2 Job
Boring holes under Roads / Railway Track / Hard standing by trenchless technology using ultra sounding technique of size 315mm dia with and including provision of HDPE pipe 280mm dia, suitable for inserting 250mm dia DI pipe line and 0.4 MPa working pressure, complete all as specified and directed.
SUMMER APPLIANCES Supply, installation, testing and commissioning of Hi-wall split type air conditioning unit (inverter type copper), BEE Five star rating (2018) of capacity 1.5TR complete with drive motor air cooled condenser with all accessories varied speed and dual invertor type rotary compressor, including fixing the out doore units as per manufacturer recommondation and fixing indoor unit on wall, proving and making interconnection including refrigerent piping (upto 7.5 RM) with nytrile rubber insulation and control cable from indoor to outdoor, power cabling from isolator / encloser to unit, first charging of CFC & HCFC free refrigerent gas including cord less remot, drain piping of 25 mm dia connecting drain lines from indoor unit to maximum of 3.0 metre to nearest drain points and making good the disturbed surfaces of wall to match with the existing surfaces, complete all as specified and directed.
Supply, installation, testing and commissioning of vertical pack type air conditioning units indoor / outdoor complete of EER / BEE of minimum 03 star rating with cordless remot control unit, scroll / rotary compressor, three phase units 415 volts, 50 Hz of capacity of minimum 2.5TR complrte with all accessories, including fixing the outdoor unit as per recommondation, proving and making interconnection including refrigerent piping (upto 7.5 metre) with nytrile rubber insulation and control cable from indoor to outdoor, power cabling from isolator / encloser to unit, first charging of CFC & HCFC free refrigerent gas including drain piping of 25mm dia for connecting drain lines from indoor unit to required length as per site requirement nearest drain points and making good the disturbed surfaces of wall to match with the existing surfaces, including fly ash brick masonory work in CM 1:4 if required for closing the holes of wall on both sides externaly and internally, complete all as specified and directed.
Hard copper pipe of suction / discharge line of vertical air conditioner including rubber pipe insulation, fixing accessories, for the following sizes, complete all as specified and directed. NOTE:- One run of copper pipe along with insulation pipe shall be measured as one unit length.
15 mm dia pipe
20 mm dia pipe
Single phase voltage stabiliser with intelligent time delay system, low / high voltage cut off, built in thermal over load protection micro controlled operation, seven segment digital display with smart LED Ring, 50 Hz AC supply and suitable correct of input voltage of 140 to 280 voltage of output stabilized at 220 V of capacity 4 KVA (for INVERTOR AC's), complete all as specified and directed.
COOLING APPLIANCES Supply, installation, commissioning of refrigerator single phase 240 volt, 50 Hz of capacity not less than 465 litre, double door, frost free with digital invertor compressor having 4-star rating, complete all as specified and directed.
Supply, installation, commissioning of double door Metal Top Deep Freezer single phase 240 volt, 50 Hz of minimum capacity 425 litre, complete all as specified and directed.
Supply, installation, commissioning of Water cooler fully stainless steel body, electric driven single phase having approximate storage and nominal cooling capacity 150 / 150 litre, complete all as specified and directed.
Single phase voltage stabiliser with intelligent time delay system, low / high voltage cut off, built in thermal over load protection micro controlled operation, seven segment digital display with smart LED Ring, 50 Hz AC supply and suitable correct of input voltage of 135 to 280 voltage of output stabilized at 220 V, of capacity 1 KVA (for Deep Freezer, Refrigerator & Water Cooler), complete all as specified and directed.
FIRE FIGHTING Providing and installing in position, 30 mtr long and 63mm dia woven jacketed fire hose (Hewage / Fire Marshall) with external coat of synthetic fibre and EPDM rubber lining from inside having 42 Kg/cm2 burst pressure, 18 Kg/cm2 working pressure conforming to IS 636 with ISI mark along with ISI Marked brass coupling, ISI marked short size gun metal branch pipe with 63mm instanteneous male inlet, complete all as specified and directed.
Cast iron air release valve suitable for 50 mm bore CI pipe as per IS-14845, ISI marked including all joints with rubber or fibre board, bolts and nuts, washers etc complete all as specified.
Design supply, install, testing & commissioning passengers lift for 08 passengers (544 KG), speed 1.5 metre/sec, lift with single speed motor 415 volts, 3 phase, AC 50 Hz supply conforming to IS-14665-1(2000), suitable to serve G+08 (for OR's Block) upper floors with AC Variable Voltage & Variable Frequency drive (VVVF drive) micro processor controlled Auto Rescue Device (ARD, 3D infra red sensor in full height of door & built in announcing system without handset (10 Nos, one each in car, machine room & near ground floor landing door) drive system on the micro processor controlled with power driven automatic sliding door (COPD) suitable to the size of car having stainless steel panels in hairline finish No. 04, SS sliding door, PVC flooring in cabin, SS Hair line finish No. 04 ceiling, door operation automatic, entrance protection, 3D full height infra red curtain door detector system, indicators (landing / car) with DOT Matrix type direction and position indicators with stainless steel face plates (for car-full length COP shall be provided), press and speak three way intercom with speaker, SS Hand Rails in mirror finish, hall lantern (up / down) and Gong indicator arrangement, pit ladder and balustrade, over load warning signal, battery operated alarm bell and emergency light, announcement system with music, stop switch, auto cut-off car fan switch, door open and close button, do's and dont's information necessary items for the erection of the elevator complete all as per standard design of manufacturer complete with a speed of approximately 1.5 metre/second to serve ground floor to eighth floor (total of 09 floors including ground floor), complete all as specified and directed.
Design supply, install, testing & commissioning passengers lift for 08 passengers (544 KG), speed 1.5 metre/sec, lift with single speed motor 415 volts, 3 phase, AC 50 Hz supply conforming to IS-14665-1(2000), suitable to serve G+06 (for JCO's Block) upper floors with AC Variable Voltage & Variable Frequency drive (VVVF drive) micro processor controlled Auto rescue device (ARD, 3D infra red sensor in full height of door & built in announcing system without handset (8 Nos, one each in car, machine room & near ground floor landing door) drive system on the micro processor controlled with power driven automatic sliding door (COPD) suitable to the size of car having stainless steel panels in hairline finish No. 04, SS sliding door, PVC flooring in cabin, SS Hair line finish No. 04 ceiling, door operation automatic, entrance protection, 3D full height infra red curtain door detector system, indicators (landing / car) with DOT Matrix type direction and position indicators with stainless steel face plates (for car-full length COP shall be provided), press and speak three way intercom with speaker, SS Hand Rails in mirror finish, hall lantern (up / down) and Gong indicator arrangement, pit ladder and balustrade, over load warning signal, battery operated alarm bell and emergency light, announcement system with music, stop switch, auto cut-off car fan switch, door open and close button, do's and dont's information necessary items for the erection of the elevator complete all as per standard design of manufacturer complete with a speed of approximately 1.5 metre / second to serve ground floor to sixth floor (total of 07 floors including ground floor), complete all as specified and directed.
Design supply, install, testing & commissioning Goods lift to carry 1000 KG, speed 1.5 metre/sec, lift with single speed motor 415 volts, 3 phase, AC 50 Hz supply conforming to IS-14665-1(2000), suitable to serve G+08 (for OR's Block) upper floors with AC Variable Voltage & Variable Frequency drive (VVVF drive) micro processor controlled Auto rescue device (ARD, 3D infra red sensor in full height of door & built in announcing system without handset (9 Nos, one each in car, machine room & near ground floor landing door) drive system on the micro processor controlled with power driven automatic sliding door (COPD) suitable to the size of car having stainless steel panels in hair line finish No. 04, SS sliding door, PVC flooring in cabin, SS Hair line finish No. 04 ceiling, door operation automatic, entrance protection, 3D full height infra red curtain door detector system, indicators (landing / car) with DOT Matrix type direction and position indicators with stainless steel face plates (for car-full length COP shall be provided), press and speak three way intercom with speaker, SS Hand Rails in mirror finish, hall lantern (up / down) and Gong indicator arrangement, pit ladder and balustrade, over load warning signal, battery operated alarm bell and emergency light, announcement system with music, stop switch, auto cut-off car fan switch, door open and close button, do's and dont's information necessary items for the erection of the elevator complete all as per standard design of manufacturer complete with a speed of approximately 1.5 metre / second to serve ground floor to eighth floor (total of 09 floors including ground floor), complete all as specified and directed.
Design supply, install, testing & commissioning Goods lift to carry 1000 KG, speed 1.5 metre/sec, lift with single speed motor 415 volts, 3 phase, AC 50 Hz supply conforming to IS-14665-1(2000), suitable to serve G+06 (for JCO's Block) upper floors with AC Variable Voltage & Variable Frequency drive (VVVF drive) micro processor controlled Auto rescue device (ARD, 3D infra red sensor in full height of door & built in announcing system without handset (8 Nos, one each in car, machine room & near ground floor landing door) drive system on the micro processor controlled with power driven automatic sliding door (COPD) suitable to the size of car having stainless steel panels in hair line finish No. 04, SS sliding door, PVC flooring in cabin, SS Hair line finish No. 04 ceiling, door operation automatic, entrance protection, 3D full height infra red curtain door detector system, indicators (landing / car) with DOT Matrix type direction and position indicators with stainless steel face plates (for car-full length COP shall be provided), press and speak three way intercom with speaker, SS Hand Rails in mirror finish, hall lantern (up / down) and Gong indicator arrangement, pit ladder and balustrade, over load warning signal, battery operated alarm bell and emergency light, announcement system with music, stop switch, auto cut-off car fan switch, door open and close button, do's and dont's information necessary items for the erection of the elevator complete all as per standard design of manufacturer complete with a speed of approximately 1.5 metre / second to serve ground floor to sixth floor (total of 07 floors including grounf floor), complete all as specified and directed.
Earthing complete with GI earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground vertically to a depth of not less than 2.25m deep below ground level with the top edge of earth plate at a depth of not less than 1.5m below ground level connected to GI earth strip 25mm x 4mm by means of bolts, nuts, washers of galvanised iron or steel, GI earth strip shall be protected by 40mm dia GI pipe 'medium grade', watering pipe 20mm dia GI pipe 'light grade', GI wire meshed funnel, alternate layer of charcoal and salt on all side to earth plate upto a thickness of 150mm, filling of black cotton soil in earth pit upto GL and connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber, 40mm thick RCC cover (1:2:4) mix with 6mm dia nominal reinforcement @ 150mm c/c both ways etc complete all as shown in electrical plate No.3 connected to earthing test point, including testing on completion, complete all as speciifed and as directed. NOTE:- (a) Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50metre, PCC pit, funnel and RCC cover plate. (b) Earth continuity conductor beyond 7.5metre shall be measured and paid under respective item of this Schedule.
Supplying, installing, testing & commissioning of factory assembled Diesel Engine driven Generating Set coupled with alternator AC to give continuous output of 250 KVA/200 KW at a power factor of 0.8 lagging, 415 volts, AC, 3 phase, 4 wire, 50 HZ, 1500 RPM, directly coupled with diesel engine radiator cooled, mounted on common base frame complete with suitable fuel tank of suitable capacity as recommended by OEM with fuel line & accessories, PCC foundation work as per manufacture's instructions, AVM pads, micro processed relay based panel for automatic starting on mains failure, OEM recommended AMF panel showing all parameters of engine & alternator, sound proof canopy & other accessories etc. and confirming to the undermentioned technical specifications complete in all respect and all as specified and directed. (A) DIESEL ENGINE: 6 cylinders in line water cooled, radiator cooled, turbo charged - after cooled, 1500 RPM under NTP conditions IS 10002, BS 5514, ISO 3046, conforming to with an overload capacity of 10% for 01 hour of continuous operation with minimum 309 BHP suitable for 250 KVA alternator with the following accessories all as recommended by OEM. (i) Fly wheel housing and fly wheel. (ii) Air cleaner dry type replaceble paper element type. (iii) Vacuum indicator. (iv) Electronic governor / G3. (v) Exhaust silencer.
Sl. item No. 61.00 Contd... (vi) Dual fuel filter. (vii) Fuel injection pump (FIP). (viii) Fan & water pump assembly. (ix) Lub oil filter & pump & first fill tube oil and coolant and diesel during commission and testing. (x) Electric starting system with battery charging alternator and axial type starter motor including adequate number of high capacity maintenance free lead acid battery, 24 volts 180 AH-02 Nos DC Make: Amarraja / Exide / Microtex / Luminous or as recommended by OEM including interconnecting cables / leads with terminals complete with starting / stopping switch, voltmeter etc - 01 Set. (xi) Engine safety shut down system against low lub oil pressure and high water pressure / coolant temparature pressure. (xii) Exhaust gas driven trubo charger. (xiii) Oil filter. (xiv) Lub oil cooler. (xv) Engine maintenance manual with spare parts list. (xvi) Factory made corrosion resistant, acoustic enclosure (canopy) well suitable for 250 KVA DG set to reduce noise level to 75 db (A), measured at 1.00, meter distance @75% load under free field conditions as per guidelines of MOEF / CPCB & comprising of following: -
Sl. item No. 61.00 Contd... (i) Sound proof FOAM insulation complying to IS 8183 with durable industrial locking system on doors, doors with gasket made of high quality EDPN Material and Common base frame. (B) ENGINE INSTRUMENT PANEL: Digital type indicating the following: - Integrated control panel system microprocessor based genrater set monitoring and electronic governing system.the control system should have power start 0500 control microprocessor based genrator set monitoring and control system mounted in the gen set control panel. The control should provides a simple operator interface to the genrator set, AMF start / stop control, shut down fault indication and LCD display as following: - (i) Starting switch on / off. (ii) Water Temp guage. (iii) Hour meter cum RPM indicator. (iv) Lub oil pressure gauge. (v) Lub oil temperature gauge. (vi) Battery charging meter. (v) OEM recommended AMF panel including auto by pass system suitable for 250 KVA / 200 KW DG set complete with, power contact, relays, timers, set of CTs for metering and protection and energy analyzer to indicate currents, phase and line voltages, frequency, power factor, KWH, KVAH & provision for overload, short circuit, restricted earth fault complete contol cabling etc.
Sl. item No. 61.00 Contd... (C) ALTERNATOR shall be self excited, self regulated, brush less for 200 KW /250 KVA at the speed of 1500 RPM at 415 volts, 50Hz, three phase 4 wire system with advance electric voltage regulator to ensure high voltage accuracy with + 1% with class H insulation and SPDP enclosure directly coupled with engine through flexible coupling and confirming IS-4722 complete - 1 No. (D) Common fabricated base frame for engine & alternator made from structural channel, jerk proof PCC 1:2:4 typw B1 foundation including adequate number of suitable anti-vibration pads all as per the recommendation of the manufacture- 01 No NOTE:- Cost of suitable size of PCC foundation is deemed to be included in the unit rate quoted by the contractor. (E) Battery- 24 volt not less than 180 AH-02 Nos with connecting lead. (F) In built steel fuel tank fabricated out of 14 SWG MS sheet mounted inside the encloser along with fuel piping from tank to engine capacity as recommended by OEM with drain valve, air vent inlet outlet connection. (G) Suitable exhaust pipe duly claded with glass wool and covered with aluminimum sheet inside the encloser silencer mounted on the top of enclosers and exhaust trail pipe and with muffer complete all as per manufacture's design.
Supply, install, test & commissioning LT panel CPRI certified fy made, in door, floor mounted / pedestal type, cubical, compartmentalised, self supported, IS / IES 61439 1&2, front and rear openable, hinged type with locking arrangement on front and rear, suitable ventilations on both sides with wire mesh, with dust and vermin proof, etc. fabricated out of 2mm thick CRCA sheet duly powder coated with chemical process, mounted / fixed on and including MS angle iron stand / frame 40cm height from FFL, fabricated out of 50x50x6 mm thick MS angles duly painted with black enamel synthetic paint over a red oxide primer duly grouted in PCC 1:3:6 foundation, control wiring copper stranded PVC insulated FRLS cables not less than 1.5 sqmm, suitable size / capacity of aluminium strips for switch gear connection from main bus bar, two runs of GI earth strip of 32 x 6mm size on the rare side of the panel, suitable size of MS gland with gland plate and alluminium lugs / thimbles for all incoming / out going cables etc., with and including provision of the following accessories, complete all as specified and directed: (a) MCCB 4 pole, 415 Volts, 315 Amps rating, Ics =100% Icu rupturing capacity 36 KA adjustable thermal setting, adjustable over load and short circuit setting - 01 No (incoming). (b) MCCB 4 pole, 415 Volts, 63 Amps rating, Ics =100% Icu rupturing capacity 16 KA adjustable thermal setting, adjustable over load and fixed short circuit protection - 06 Nos (out going) (for Passenger - 02 & Goods Lifts - 02 and Firefighting pumps panel as Single ORs Accn + 01 Spare).
Sl. item No. 62.00 Contd... (c) MCCB 4 pole, 415 Volts, 40 Amps rating, Ics = 100% Icu rupturing capacity 16 KA adjustable thermal setting, adjustable over load and fixed short circuit protection - 01 No (out going) (for Religious building). (d) MCCB 4 pole, 415 Volts, 25 Amps rating, Ics = 100% Icu rupturing capacity 16 KA adjustable thermal setting, adjustable over load and fixed short circuit protection - 05 Nos (out going) (for Street lights, Common Lights at JCO's & OR's Block and Firefighting pumps at JCOs ORs Accn + 01 Spare). (e) MCCB 4 pole, 415 Volts, 200 Amps rating, Ics = 100% Icu rupturing capacity 25 KA adjustable thermal setting, adjustable over load and fixed short circuit protection - 03 Nos (Out going) (for Pump house + 01 Spare). (f) Digital type multi functional panel meter 96 sq.mm, Amps, Voltage, Frequency, PF & KWH with suitable CT's - 01 set. (g) LED type phase indicator with controlling fuses for RYB - 02 sets (One set mounted on incoming compartment and 01 set mounted on each out going compartment). (h) Electrolyte aluminium bus bars TPN for phases and neutral 500 Amps with PVC coloured sleeves mounted on hygroscopic insulator duly colour coded RYB - 01 set.
Supply, install test and commissioning of CPRI certified, factory fabricated, supply, installation, testing and commissioning of LT panel board, 3 phase, 4 wire, 415 Volts, outdoor type conforming to IS / IEC-61439-1&2 with internal arc containment, IP 43 protection, epoxy painted after 7 tank surface treatment floor / wall mounted (minimum height after foundation above the floor 20cm and width as equal or more than panel width and tight with nut and bolts with PCC), totally enclosed, cubical type, dust and vermin proof fabricated out of 2.15mm thick CRCA sheet and suitable size section of MS angle iron frame and front openable construction, enclosure class IP-45, powder coated including making opening for mounting meters, top / bottom removable gland plates as required hinged, double door with suitable locking system, pre-wired with suitable size of single core PVC insulated FRLS stranded copper conductor cable, 2.5 sqmm, 1100 volts graded as connecting leads and alluminium strip of 200 Amp rating for connections from bus bar to MCCB, aluminium bus bar for 3 phase and four wire system of 200 Amp rating and all connections and including PCC foundations with PCC 1:3:6 type C-1 (using 20mm graded aggregate) of above mentioned size finished even and smooth to exposed surfaces including necessary fixing arrangements suitable for and including provision of the following accessories, complete all as specified and directed:
All as per Sl. Item No. 64.00 here-in-before, but for ceiling fan / exhaust fan point / wall fan controlled one number one-way switch
All as per Sl. Item No. 64.00 here-in-before, but for one light controlled by two two-way switches
All as per Sl. Item No. 64.00 here-in-before, but for one switch socket outlet point 5Amp on independent board
All as per Sl. Item No. 64.00 here-in-before, but for one switch socket outlet point 5Amp on same board
All as per Sl. Item No. 70.00 here-in-before, but for ceiling fan / exhaust fan point / wall fan controlled one number one-way switch
MCB DB TPN 4 way vertical, metallic, double door IP 54 protection, 415 V AC 50Hz including MCCB Four Pole 63 Amp,16 KA -01 No as incomer and MCCB Four pole 40 Amp, 10 KA -02 Nos as Out going with tinned copper bus bar of rated 200 Amps, neutral link earth link, complete all as specified and directed.
MCCB 4 pole 415V, 63 Amps, 50 Hz with thermal magnetic release and Ics=100%Icu with rupturing capacity 16 KA, adjustable overload min 70-100% including enclosure, complete all as specified and directed.
Flame proof MCB 25 Amp Double pole, 240 Volts including LM 6 enclosure, complete all as specified and directed
MCB, TP, 40 Amps , 240 Volt, 50HZ, 10 KA, `C` series including making electrical connection with the help of legs/thimbles, complete all as specified and directed.
MCB, TP, 16 Amps , 240 Volt, 50HZ, 10 KA, `C` series including making electrical connection with the help of legs/thimbles, complete all as specified and directed.
MCB, SPN, 32 Amps , 240 Volt, 50HZ, 10 KA, `C` series including making electrical connection with the help of legs / thimbles, complete all as specified and directed.
Supply fixing MCB, SPN, 25 Amps , 240 Volt, 50HZ, 10 KA, `C` series including making electrical connection with the help of legs / thimbles, complete all as specified and directed.
MCB, SPN, 16 Amps , 240 Volt, 50HZ, 10 KA, `C` series including making electrical connection with the help of legs / thimbles, complete all as specified and directed.
MCB, SPN, 10 Amps , 240 Volt, 50HZ, 10 KA, `C` series including making electrical connection with the help of legs / thimbles, complete all as specified and directed.
MCB, SP, 40 Amp , 240 Volt, 50HZ, 10 KA, `C` series including making electrical connection with the help of legs / thimbles, complete all as specified and directed.
MCB, SP, 32 Amp , 240 Volt, 50HZ, 10 KA, `C` series including making electrical connection with the help of legs / thimbles, complete all as specified and directed.
MCB, SP, 20 Amp , 240 Volt, 50HZ, 10 KA, `C` series including making electrical connection with the help of legs / thimbles, complete all as specified and directed.
MCB, SP, 16 Amp , 240 Volt, 50HZ, 10 KA, `C` series including making electrical connection with the help of legs / thimbles, complete all as specified and directed.
MCB, SP, 10 Amp , 240 Volt, 50HZ, 10 KA, `C` series including making electrical connection with the help of legs / thimbles, complete all as specified and directed.
MCB, SP, 6 Amp , 240 Volt, 50HZ, 10 KA, `C` series including making electrical connection with the help of legs / thimbles, complete all as specified and directed.
Sub main wiring complete with four runs of single core 16 sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawn through and including provision of concealed non-metallic rigid PVC conduit of size not less than 32mm dia and its accessories and connecting terminal ends to DB's including providing two runs of 16 sq.mm PVC insulated unsheathed multistranded FRLS grade copper cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed. NOTE:- (i) Four runs of 16 sq.mm copper conductor, two runs of 16 sq.mm copper earth continuity conductor and one run of PVC conduit shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly.
Sub main wiring complete with four runs of single core 10 sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawn through and including provision of concealed non-metallic rigid PVC conduit of size not less than 32mm dia and its accessories and connecting terminal ends to DB's including providing two runs of 10 sq.mm PVC insulated unsheathed multistranded FRLS grade copper cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed. NOTE:- (i) Four runs of 10 sq.mm copper conductor, two runs of 10 sq.mm copper earth continuity conductor and one run of PVC conduit shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly.
Sub main wiring complete with four runs of single core 6 sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawn through and including provision of concealed non-metallic rigid PVC conduit of size not less than 32mm dia and its accessories and connecting terminal ends to DB's including providing two runs of 6 sq.mm PVC insulated unsheathed multistranded FRLS grade copper cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed. NOTE:- (i) Four runs of 6 sq.mm copper conductor, two runs of 6 sq.mm copper earth continuity conductor and one run of PVC conduit shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly.
Sub main wiring complete with four runs of single core 4 sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawn through and including provision of concealed non-metallic rigid PVC conduit of size not less than 32mm dia and its accessories and connecting terminal ends to DB's including providing two runs of 4 sq.mm PVC insulated unsheathed multistranded FRLS grade copper cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed. NOTE:- (i) Four runs of 4 sq.mm copper conductor, two runs of 4 sq.mm copper earth continuity conductor and one run of PVC conduit shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly.
Sub main wiring complete with two runs of single core 2.5 sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawn through and including provision of concealed non-metallic rigid PVC conduit of size not less than 25mm dia and its accessories and connecting terminal ends to DB's including providing one run of 2.5 sq.mm PVC insulated unsheathed multistranded FRLS grade copper cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed. NOTE:- (i) Two runs of 2.5 sq.mm copper conductor, one run of 2.5 sq.mm copper earth continuity conductor and one run of PVC conduit shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly.
Sub main wiring complete with two runs of single core 4 sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawn through and including provision of concealed non-metallic rigid PVC conduit of size not less than 25mm dia and its accessories and connecting terminal ends to DB's including providing one run of 4 sq.mm PVC insulated unsheathed multistranded FRLS grade copper cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed. NOTE:- (i) Two runs of 4 sq.mm copper conductor, one run of 4 sq.mm copper earth continuity conductor and one run of PVC conduit shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly.
Sub main wiring complete with two runs of single core 4 sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawn through and including provision of concealed stove enamelled steel conduit of size not less than 25mm dia and its accessories and connecting terminal ends to DB's including providing one run of 4 sq.mm PVC insulated unsheathed multistranded FRLS grade copper cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed. NOTE:- (i) Two runs of 4 sq.mm copper conductor, one run of 4 sq.mm copper earth continuity conductor and one run of stove enamelled steel conduit shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly.
Supply, Fixing and testing of 4ft LED surface & wall mounted batten LED luminaires, 20 Watts, with latest LED technology and efficient optics ensuring perfectly uniform illumination and unparallelleled light distribution high optically efficient serrated diffuser, Isolated Multistage CCCV driver with voltage range 150-270V AC, temperature range- 0 to 50 degree Centigrade, CRI >80, class-1, SDCM <5, Driver efficiency>85%, Power factor >0.95, THD<10%, Colour temperature-6500K, short circuit and over circuit protection, Surge protection- 3KV in CM, Safety Extra Low Voltage Safe level<60V DC as per IS-10322/IEC-60598 standard, IP20 protected, 50000 burning hours, with 70% of its initial lumen maintained, Lumianire efficacy>100lm/W fixed complete including all accessories and provision of PVC sheathed 3 core 1.5 sq.mm copper conductor for connection, complete all as specified and directed. MAKE: Cat No.LGLZ01X020XC of Jaquar or techno-commercially equvalant model in BAJAJ / Crompton Greaves / Philips
Supply, Fixing and testing of 2ft surface & wall mounted LED batten luminaires, 10 Watts, with latest LED technology and efficient optics ensuring perfectly uniform illumination and unparalled light distribution high optically efficient serrated diffuser, Isolated Multistage CCCV driver with voltage range 150-270V AC, temperature range- 0 to 50 degree Centigrade, CRI >80, class-1, SDCM <5, Driver efficiency>85%, Power factor >0.95, THD<10%, Colour temperature-6500K, short circuit and over circuit protection, Surge protection- 3KV in CM, Safety Extra Low Voltage Safe level<60V DC as per IS-10322/IEC-60598 standard, IP20 protected, 50000 burning hours, with 70% of its initial lumen maintained, Lumianire efficacy>100lm/W fixed complete including all accessories and provision of PVC sheathed 3 core 1.5 sq.mm copper conductor for connection, complete all as specified and directed. MAKE: Cat No.LGLZ01X010XC of Jaquar or techno-commercially equvalant model in BAJAJ / Crompton Greaves / Philips
Supply and fixing and testing 45 W High efficient LED street light fitting, Aluminium pressure Die cast housing parts for longlife,Pure polyester powder coated Dark Gray housing, High purity PMMA lenses for superior performance, Toughened glass with silicon gaskets for IP65protection, Driver cover designed to suit top maintenance,Suitable for external pole dia. Up to 50 mm, LED make- Nichia, Power factor>0.95, Lumianire lumen output- 6440lm, CCCV driver with Voltage range 150-270V AC, Temperature range- 0 to 50DegC, Driver efficiency > 85%, Power factor > 0.95, THD<10%, CRI >70, Colour Temperature- 5700K, Surge protection from overvoltages- 4.0KV in CM, 50000 burning hours, Luminaire efficacy >92lm/W including provision of 1.5 sq.mm 3 core multistranded PVC copper conductor and PVC conduit with fixing accessories for connection between junction box and street light fitting, complete all as specifired and directed. MAKE: Cat No.LSRT01S045XC of Jaquar or techno-commercially equivalant model in BAJAJ / Crompton Greaves / Philips
LED Bulb, 9W, complete all as specified and directed. MAKE: Cat No.LED BULB(9W) of Jaquar or techno-commercially equivalant model in BAJAJ / Crompton Greaves / Philips
Supply, Fixing and testing of 1 ft surface & wall mounted Mirror Light luminaires, 7 Watts, with latest LED technology and efficient optics ensuring perfectly uniform illumination and unparalled light distribution high optically efficient serrated diffuser, Isolated Multistage CCCV driver with voltage range 150-270V AC, temperature range- 0 to 50 degree Centigrade, CRI >80, class-1, SDCM <5, Driver efficiency>85%, Power factor >0.95, THD<10%, Colour temperature-6500K, short circuit and over circuit protection, Surge protection- 3KV in CM, Safety Extra Low Voltage Safe level<60V DC as per IS-10322/IEC-60598 standard, IP20 protected, 50000 burning hours, with 70% of its initial lumen maintained, Lumianire efficacy>100lm/W fixed complete including all accessories and provision of PVC sheathed 3 core 1.5 sq.mm copper conductor for connection, complete all as specified and directed. MAKE: Cat No.SM250LED7S-6500PSUWH of Philips or techno-commercially equivalent model in BAJAJ / Crompton Greaves / Jaquar
LED Flame-proof CMRI Certified 1x16/20W fitting complete with all accessories prewired and including connecting and testing, complete all as specified and directed. MAKE: Cat No.EXTN 1LT8-1120 of Crompton Greaves or techno-commercially equivalent model in BAJAJ / Jaquar / Philips
Supply, fixing and testing of Highbay LED welglass pendent / ceiling mounted luminaire LED, Wattage 35W with housing made up of white powder coated, pressure die cast aluminium for effective thermal management, Injection molded translucent white impact resistant polycarbonate diffuser, In-built integrated Electronic LED driver pre wired up to terminal block with luminaire lumen ≥ 3325lm and System Efficacy ≥ 95lm/W. CRI>70, LED Efficacy>135lm/W, color temperature-5700K, IP66,50000 burning hours as per L70 Criteria, Ambient temp-0 to 45 degree Centigrade, Driver efficiency>85%, THD<10%, Powerfactor>0.95, Surge protection 4.0KV, Multistage Isolated Constant Current Operated driver with range 150-270V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard, complete all as specified and directed. MAKE: Cat No.LWGL01X035XC of Jaquar or techno-commercially equivalent model in BAJAJ / Crompton Greaves / Philips
Supply, fixing and testing of High efficient Integral cradle mount Flood Light LED luminaire with Aluminium pressure Die cast housing parts for long life, Polycarbonate diffuser for superior performance, Toughened glass with silicon gaskets for IP66 protection, Complete assembly with LED, Driver and accessories pre- wired up to terminal block. SMD Floodlight, Wattage ≤80W with luminaire lumen ≥ 8000lm and System Efficacy ≥ 100lm/W, CRI >70,Temperature range- 0 to 40 degree Centigrade, Driver efficiency>85%, Power factor>0.95, THD<10%, Colour Temperature- 5700K, Surge protection 4KV, 50000 burning hours as per L70 Criteria, Multistage Isolated Constant Current Operated driver with range 150-270V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard, complete all as specified and directed. MAKE: Cat No. BVP120LED70CWFGS1 PSU GR of Philips or techno-commercially equivalent model in BAJAJ / Crompton Greaves / Jaquar
Supply, fixing and testing of Aviation Obstruction twin Light Fitting with neon lamp fixed on roof of the building including making connections, complete all as specified and directed. MAKE: Cat No. BJAOL1-75VA of BAJAJ:or techno-commercially equivalent model in Philips / Crompton Greaves / Jaquar
Ceiling fan BEE 5 star rated complete 1200mm sweep, energy efficient suitable to function on 230V, single phase, AC supply, white colour, with down rod 300mm long, capacitor 2.5mF, canopies, nuts, bolts and washers and connecting with and including provision of 3 core 1.5 sq.mm PVC sheathed flexible copper conductor from ceiling, writing MES number on ceiling fan motor complete all as specified and directed.
Heavy duty exhaust fan 300mm sweep 900RPM cast iron body and blades with louvers and shutters without regulator suitable for 230V single phase AC supply with all fixing arrangments to fix on wall, including making holes on brick / stone walls and making good disturbed surfaces to match with the existing, including provision of 3-way procelain connector, copper bunched flexible three core 1.5sq.mm PVC insulated cable from connection point to fan, writing MES number on exhaust fan motor, complete all as specified and directed
Exhaust fan, Flame proof, 230 Volt 50 Hz single phase AC supply, 300 mm sweep with louver complete with metal body powder coated with protective steel bird guard on wall including provision of 3 core 1.5 sq mm cable from ceiling rose to exhaust fan including writing MES number on exhaust fan motor, complete all as specified and directed.
Heavy duty exhaust fan 450mm sweep 900RPM cast iron body and blades with louvers and shutters without regulator suitable for 230V single phase AC supply with all fixing arrangments to fix on wall, including making holes on brick / stone walls and making good disturbed surfaces to match with the existing, including provision of 3-way procelain connector, copper bunched flexible three core 1.5sq.mm PVC insulated cable from connection point to fan, writing MES number on exhaust fan motor, complete all as specified and directed
Air Circulator wall fans 230 volts single phase oscillating 400 mm sweep suitable for wall mounting ,oscillation up to 90 degrees and metal body poweder coated complete with all fixing accessories on wall complete and marking MES number on fan motor, complete all as specified and directed.
Design, manufacture, supplying, installing in correct aligned position, making proper connections, testing and commissioning of following LV panels suitable for 415 V, 3 phase, 4 wire, 50 Hz power distribution system. The panel shall be Indoor IP42 rating, free standing, floor/wall mounting, sheet metal clad, cubicle,dust and vermin proof type compartmentalized design fabricated out of 16SWG CRCA sheet steel, complete with aluminium bus bars of 400 Amp insulated with heat shrinkable sleeves and colour coded, separate earth bus bar to be provided through out the length of the panel. The incoming and outgoing feeders shall be accommodated in a modular multitier arrangement and shall be interlocked to avoid paralleling, adequate size cable alley, painting, numbering, danger plate etc as required as per specifications and drawings, with and including provision of the following, complete all as specified and directed. Incoming : MCCB 4 pole 415V, 250 Amps, 50 Hz with thermal magnetic release and Ics=100%Icu with rupturing capacity 36 KA, adjustable overload min 70-100%-)1 No. Metering & Indication : LED Indicating lamps set RYB - 01 set
Sl. item No. 109.00 Contd... Outgoings : MCCB 4 pole 415V, 100 Amps, 50 Hz with thermal magnetic release and Ics=100%Icu with rupturing capacity 25 KA, adjustable overload min 70-100% -8 Nos.(Outgoing) MCCB 4 pole 415V, 63 Amps, 50 Hz with thermal magnetic release and Ics=100% Icu with rupturing capacity 16 KA, adjustable overload min 70-100% -13 Nos.(Outgoing) Multi function energy meter, 3 lines seven sgmant display, 3 phase, 3 or 4 wire CT-PT operated multi function meter of class 1.0 accuracy with RS 485 and THD for V & I panel mounted 96 x 96 sqmm flush mounted case -01 No
Design, manufacture, supplying, installing in correct aligned position, making proper connections, testing and commissioning of following LV panels suitable for 415 V, 3 phase, 4 wire, 50 Hz power distribution system. The panel shall be Indoor IP42 rating, free standing, floor/wall mounting, sheet metal clad, cubicle,dust and vermin proof type compartmentalized design fabricated out of 16SWG CRCA sheet steel, complete with aluminium bus bars of 1000 Amp insulated with heat shrinkable sleeves and colour coded, separate earth bus bar to be provided through out the length of the panel. The incoming and outgoing feeders shall be accommodated in a modular multitier arrangement and shall be interlocked to avoid paralleling, adequate size cable alley, painting, numbering, danger plate etc as required as per specifications and drawings, with and including provision of the following, complete all as specified and directed. Incoming : Air Circuit Breaker 630Amp with thermalmagnetic release Draw out type will have inbuilt 2NO+2NC Aux contact for MDO & 6NO+6NC Aux contact for EDO brakers, safety shutter assembly, Racking handle, Door sealing frame, Push-button cover & Rating error preventor-01 No(Incoming)
Sl. item No. 110.00 Contd... Metering & Indication : LED Indicating lamps set RYB …. 01 set Outgoings : MCCB 4 pole 415V, 125 Amps, 50 Hz with thermal magnetic release and Ics=100%Icu with rupturing capacity 25 KA, adjustable overload min 70-100% -01 Nos.(Outgoing) MCCB 4 pole 415V, 100 Amps, 50 Hz with thermal magnetic release and Ics=100%Icu with rupturing capacity 25 KA, adjustable overload min 70-100% -13 Nos.(Outgoing) MCCB 4 pole 415V, 63 Amps, 50 Hz with thermal magnetic release and Ics=100%Icu with rupturing capacity 16 KA, adjustable overload min 70-100% -04 Nos.(Outgoing) Multi function energy meter, 3 lines seven sgmant display, 3 phase, 3 or 4 wire CT-PT operated multi function meter of class 1.0 accuracy with RS 485 and THD for V & I panel mounted 96 x 96 sq.mm flush mounted case -01 No
Design, manufacture, supplying, installing in correct aligned position, making proper connections, testing and commissioning of following LV panels suitable for 240 V, single phase power distribution system. The panel shall be Indoor IP42 rating, free standing, floor/wall mounting, sheet metal clad, cubicle,dust and vermin proof type compartmentalized design fabricated out of 16 SWG CRCA sheet steel to accomodate with and including provision of one MCB DB SPN 8 way, complete all as specified and directed.
Air Circulator pedestal fans 230 volts single phase oscillating 600 mm sweep oscillation up to 90 degrees and metal body poweder coated complete with all accessories and marking MES number on fan motor, complete all as specified and directed.
PILE FOUNDATIONS Drilling or boring for 500mm nominal dia, bored cast-in-situ piles, through any or all type of strata i.e. soft / loose soil, stiff clay, gravel, cobble stone, compact morrum, soft conglomerate or loose boulders, disintegrated rock, weathered rocks etc., (except hard rock for socketing depth) up to top of socketing depth / foundation depth by adopting suitable method (DMC method, reverse circulation method or any other approved method using Bentonite solution) and disposal of drilling / bored materials to a distance exceeding 10 Km but not exceeding 15 Km and depositing where directed at a designated place as approved by GVMC complete all as specified and directed.
All as per Sl item No. 113 hereinbefore, but for 600mm nominal dia.
All as per Sl item No. 113 hereinbefore, but through hard rock (socketing depth into hard rock shall be 1000mm) for 500mm nominal dia.
All as per Sl item No. 113 hereinbefore, but through hard rock for foundation (socketing depth into hard rock shall be 1000mm) for 600mm nominal dia. NOTE:- (for Sl. item No. 113.00 to 116.00 here-in-before): (i) The depth of boring for piles shall be measure from existing ground / (as per reduced levels taken at the commencement of work) to the approval founding level. (ii) It shall be ensured that the waste bentonite slurry / drilled or bored material is pumped off from the premises at a designated place all as specified as directed and approved by GVMC. The distance mentioned in description of item shall be the shortest distance from the centre of the building. (iii) All channels / tanks made for bentonite circulation shall be filled with approved morrum obtained by contractor at his cost after clearing all bentonite cakes. (iv) The contractor may use the method as approved by GE for boring without any extra cost to the Govt. The rates for boring of piles shall be inclusive of any method / temporary casing that may be used by the contractor for bored piles. Nothing extra shall be paid. (v) For the purpose of payment boring / drilling, description of hard rock shall be as given in particular specification. (vi) The size of cutting tool shall not be less than diameter of pile by more than 75mm. (vii) The rates quoted by the contractor shall be inclusive of the rates for the shifting and setting up of piling rig as many times as required.
Carrying out / conducting testing piles for initial load test all as per clause 6.1.5 & 6.1.6 of IS-2911 Part- IV (1985) of 500mm bore heavy safe pile load capacity of including bringing to site all testing equipment, making arrangement for testing and removal of same after completion and recording the test results and preparing the test sheets, complete all as specified and directed.
Carrying out / conducting testing piles for initial load test all as per clause 6.1.5 & 6.1.6 of IS-2911 Part-IV (1985) of 600mm bore heavy safe pile load capacity of including bringing to site all testing equipment, making arrangement for testing and removal of same after completion and recording the test results and preparing the test sheets, complete all as specified and directed.
Carrying out / conducting testing piles for Routine load test all as per clause 6.1.5 & 6.1.6 of IS-2911 Part-IV (1985) on working pile of 500mm bore heavy safe pile load capacity of including bringing to site all testing equipment, making arrangement for testing and removal of same after completion and recording the test results and preparing the test sheets, complete all as specified and directed.
Carrying out / conducting testing piles for Routine load test all as per clause 6.1.5 & 6.1.6 of IS-2911 Part-IV (1985) on working pile of 600mm bore heavy safe pile load capacity of including bringing to site all testing equipment, making arrangement for testing and removal of same after completion and recording the test results and preparing the test sheets, complete all as specified and directed.
FIRE FIGHTING Supply, install, test & commissioning LT panel out door, floor mounted / pedestal type, cubical, compartmentalised,self supported, IS / IES 61439 1&2 rated fault of 65 KA/1 Sec, front and rear openable, hinged type with locking arrangement on front and rear, suitable ventilations on both sides with wire mesh, IP-23 protection with dust and vermin proof, sloping top canopy etc. fabricated out of 3 mm CRCA sheet duly powder coated with chemical process, mounted / fixed on and including MS angle iron stand / frame 40 cm height from FFL, fabricated out of 50 x 50 x 6 mm thick MS angles duly painted with black enamel synthetic paint over a red oxide primer duly grouted in PCC 1:3:6 foundation, control wiring copper stranded PVC insulated FRLS cables not less than 1.5 sqmm, suitable size / capacity of copper strips for switch gear connection from main bus bar, earth bus strip of suitable size for entire length of panel, suitable size of MS gland with gland plate and aluminium lugs / thimbles for all incoming / out going cables etc.complete all as directed including and accommodating the followings:- (a) MCCB 4 pole, 415 Volts, 63 Amps rating, rupturing capacity 16 KA thermal magnetic release, adjustable over load and short circuit prptection - 01 Nos (In coming) (b) MCCB 4 pole, 415 Volts, 25 Amps rating, rupturing capacity 16 KA thermal magnetic release, adjustable over load and short circuit prptection - 04 No (Out going) (c) Digital type multi functional panel meter 96 sq.mm, Amps, Voltage, Frequency, PF & KWH with suitable CT's -01 set
Sl. item No. 122.00 Contd... (d) LED type Phase Indicator with controlling fuses for RYB - 02 sets (One set mounted on incoming compartment and 01 set mounted on each out going compartment) (e) Electrolyte Aluminium bus bars TPN for phases and neutral 200 Amps with PVC coloured sleeves mounted on hygroscopic insulator duly colour coaded RYB - 01 set (f) Automatic Star Delta Starter with over load, no load, single phasing suitable for 900 LPM,40 Mtr head booster pump cum motor assembly, AC, 415 V, 3 Phase, 50 Hz, along with push buttons start and stop onsurface duly colour coaded et in to the panel box including connecting by PVC copper conductor. Cable shall be measured and paid separately under respective items - 04 Nos (g) The LT panel board shall be mounted by means of suitable bolts and nuts grouted into pedestals of size to suit the feeder pillar box made of PCC block masonry in CM 1:4, over PCC foundation of 100mm thickness in PCC 1:4:8, type D2 using 40mm graded stone aggregate, PCC coping average 75mm thick, 1:3:6, type C1, using 20mm graded stone aggregate, the exposed brick / concrete surfaces shall be rendered in CM 1:4, 10mm thick, finished fair and even and applied white wash three coats complete deemed to be inclusive of coated rate.
Supply, install, test & commissioning LT panel out door, floor mounted / pedestal type, cubical, compartmentalised, self supported, IS / IES 61439 1&2 rated fault of 65 KA/1 Sec, front and rear openable, hinged type with locking arrangement on front and rear, suitable ventilations on both sides with wire mesh, IP-23 protection with dust and vermin proof, sloping top canopy etc fabricated out of 3 mm CRCA sheet duly powder coated with chemical process, mounted / fixed on and including MS angle iron stand / frame 40 cm height from FFL, fabricated out of 50 x 50 x 6 mm thick MS angles duly painted with black enamel synthetic paint over a red oxide primer duly grouted in PCC 1:3:6 foundation, control wiring copper stranded PVC insulated FRLS cables not less than 1.5 sqmm, suitable size / capacity of copper strips for switch gear connection from main bus bar, earth bus strip of suitable size for entire length of panel, suitable size of MS gland with gland plate and aluminium lugs / thimbles for all incoming / out going cables etc. complete all as directed and accommodating the followings:- (a) MCCB 4 pole, 415 Volts, 40 Amps rating, rupturing capacity 16 KA thermal magnetic release, adjustable over load and short circuit protection - 01 No (In coming) Make: Siemens / ABB / L&T / Legrand. (b) MCCB 4 pole, 415 Volts, 25 Amps rating, rupturing capacity 16 KA thermal magnetic release, adjustable over load and short circuit prptection - 02 Nos (Out going) Make: Siemens / ABB / L&T / Legrand. (c) Digital type multi functional panel meter 96 sq mm, Amps, Voltage, Frequency, PF & KWH with suitable CT's - 01 set
Sl. item No. 123.00 Contd... (d) LED type Phase Indicator with controlling fuses for RYB - 02 sets (One set mounted on incoming compartment and 01 set mounted on each out going compartment) (e) Electrolyte Aluminium bus bars TPN for phases and neutral 200 Amps with PVC coloured sleeves mounted on hygroscopic insulator duly colour coaded RYB - 01 set (f) Automatic Star Delta Starter with over load, no load, single phasing suitable for 900 LPM, 40 Mtr head booster pump cum motor assembly, AC, 415 V, 3 Phase, 50 Hz, along with push buttons start and stop onsurface duly colour coaded set in to the panel box including connecting by PVC copper conductor. Cable shall be measured and paid separately under respective items - 02 Nos. (g) The LT panel board shall be mounted by means of suitable bolts and nuts grouted into pedestals of size to suit the feeder pillar box made of PCC block masonry in CM 1:4, over PCC foundation of 100mm thickness in PCC 1:4:8, type D2 using 40mm graded stone aggregate, PCC coping average 75mm thick, 1:3:6, type C1, using 20mm graded stone aggregate, the exposed brick / concrete surfaces shall be rendered in CM 1:4, 10mm thick, finished fair and even and applied white wash three coats complete deemed to be inclusive of coated rate.
BLANK
INTERNAL WATER SUPPLY 15mm bore dia chrominum plated angular stop cock, fancy type cast copper alloy screwed for iron pipe and fixed complete all as specified and as directed. Make: CAT Part No. G1853A1 of Parryware or Techno commercially equivalent of Jaquar ESSCO series / Hindware.
15mm bore dia chrominum plated two way angular stop cock, fancy type cast copper alloy screwed for iron pipe and fixed complete all as specified and as directed. Make: CAT Part No. G2843A1 of Parryware or Techno commercially equivalent of Jaquar ESSCO series / Hindware.
15mm bore dia chrominum plated fancy type bib taps cast copper alloy with crutch of butterfly handle, screwed down, screwed for iron pipe or for brass furrule and fixed complete all as specified and as directed. Make: CAT Part No. G1804A1 of Parryware or Techno commercially equivalent of Jaquar ESSCO series / Hindware.
Swivel shower of chrominum plated fancy type for fixing with 15mm pipe complete all as specified and as directed. Make: CAT Part No. T9927A1 of Parryware or Techno commercially equivalent of Jaquar ESSCO series / Hindware.
15mm bore dia chrominum plated fancy type concealed stop cock, cast copper alloy with butterfly handle, screwed down, screwed for iron pipe or for brass furrule and fixed complete all as specified and as directed. Make: CAT Part No. G1851A1 & G5053A1 of Parryware or Techno commercially equivalent of Jaquar ESSCO series / Hindware.
Health faucet of 1.50m length or of suitable size fixed complete all as specified and as directed. Make: CAT Part No. T9961A1 of Parryware or Techno commercially equivalent of Jaquar ESSCO series / Hindware.
Towel rail 600mm long of chromium plated fixed with and including chromium plated brass screws and wooden / plastic cleats complete all as specified and as directed. Make: CAT Part No. T6401A1 of Parryware or Techno commercially equivalent of Jaquar ESSCO series / Hindware.
Chequered cement concrete decorative paving tiles, coloured, 300mm x 300mm x 20mm thick, set, jointed and pointed in neat cement slurry in floors, complete all as specified and directed.
Chromium plated fancy type soap dish fixed complete all as specified and as directed. Make: CAT Part No. T6403A1 of Parryware or Techno commercially equivalent of Jaquar ESSCO series / Hindware.
SAWHNEY BUILDWELL LLP
M/S. KASHI KANCHAN PVT. LTD.
DES RAJ AND SONS BUILDERS PVT LTD
CH.VEERARAGHAVULU CONSTRUCTION PVT LTD
Som Projects Pvt Ltd
Komal Buildcon Pvt. Ltd.
City Promoter and Buildwell Pvt. Ltd.
SHRE GURMUKHDAS CONTRACTOR PVT. LTD.
SOOD ASSOCIATES PVT LTD
SLC PROJECTS Pvt Ltd
stage.html
html • 0.07 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.07 MB
Download all tender documents and submit your bid