| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.7 LAccepted-AOC KALIAPPA COMPLEX THRICHY ROAD RANGANATHAPURAM SULUR COIMBATORE 641 402 | COIMBATORE | COIMBATORE | TAMIL NADU | 641402 | L1 | Accepted-AOC being L1 | |
| 2 | L2₹7.9 L+₹12,310 (1.58%)Rejected-Finance | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹9.4 L+₹1.7 L (21.2%)Rejected-Finance EBENEZER C C33 1185A CHALIKAVATTOM VENNALA P O KOCHI KERALA 682 028 | ERNAKULAM | KERALA | 682028 | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹11.8 L+₹4.0 L (51.4%)Rejected-Finance PADMANABAPURAM VATTIYOORKAVU PO THIRUVANANTHAPURAM 695013 | THIRUVANANTHAPURAM | THIRUVANANTHAPURAM | KERALA | 695013 | L4 | Rejected-Finance Not being L1 |
| Sl No | Description | Qty | Unit | KEERTHI CONSTRUCTIONS L4 | Powertech Engineers L3 | S K ENGINEERS L2 | SUPER COOL L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | M&L for tank cleaning and sterilization of inside the RCC/ PVC water tanks of capacity exceeding 200 ltrs and not exceeding 500 Ltrs capacity, by disconnecting existing tank and setting aside (or lowering if required), dewatering, for repairs, cleaning, sterilization using TERBAC G5/ Inchlor-5/ NB-10/ TERBAC-G-65/ Inoxi-60/ NB-69 and Ultra violet ray : Make: Rays cleantech/ Inus water tech/ Satya enterprises and removing the dirt, sediments, scale, algae formation from inside of tank and removing from site including writing mentioning "TANK CLEANED ON" with date, month and year and hoisting if required reconnecting and re-fixing in position complete all as specified and directed with the following cleaning process of the tanks:- | 835 | Each Job | 580 ₹4,84,300 | 400 ₹3,34,000 | 390 ₹3,25,650 | 250 ₹2,08,750 Lowest |
| 1.01(a) First stage: To drain out the water by using exist valve or high capacity dewatering system. (b) Second stage: Cleaning all the algae from inside the tank by using TERBAC G-10/ Inoxi-60/ NB-69 lab tested branded chemicals and scrubbing the walls of the tank by scrubber. (c) Third stage: Fresh water cleaning with high speed jet pump. (d) Fourth stage: First bacteria screening is decertification by using TERBAC G5/ INCHLOR-5/ NB-10 a Govt. lab certified branded halogen compound of E-in-C approved equivalent product. (e) Fifth stage: Cleaning the floor of the water tank with heavy duty industrial vacum cleaner. (f) Sixth stage: Second bacteria screening and sterilization method using ultra violet ray within the tank for killing all suspected bacteria. (g) Seventh stage: Cleaning and third bacteria screening and sterilization of the tank floorby using lab tested branded chemiclasstrong oxidizing agent TERBAC-G-65/ Inoxi-60/ NB-69 or E-in-C approved equivalent product. | |||||||
| 1.02Notes: (i) The rate quoted shall be deemed to be included for removal of mud, grits and deposits etc properly from site of work and on completion of work, sterilisation certificate to submitted to Engr-in-charge. carrying out work on roof top at any height. Necessary safety measures/ precautions as per norms for work men shall be taken to avoid accident or such incident. (ii) Cleaning chemical shall be approved by Engineer -in- Charge. | |||||||
| 2.00 | All as per Sl No. 1.00 here-in-before, but water tanks of capacity exceeding 500 ltrs and not exceeding 1000 ltrs complete all as specified and directed. | 160 | Each Job | 800 ₹1,28,000 | 500 ₹80,000 Lowest | 650 ₹1,04,000 | 500 ₹80,000 Lowest |
| 3.00 | All as per Sl No. 1.00 here-in-before, but water tanks of capacity exceeding 1000 ltrs and not exceeding 2000 ltrs complete all as specified and directed. | 20 | Each Job | 1,120 ₹22,400 | 600 ₹12,000 | 1,350 ₹27,000 | 559 ₹11,180 Lowest |
| 4.00 | All as per Sl No. 1.00 here-in-before, but water tanks of capacity exceeding 2000 ltrs and not exceeding 5000 ltrs complete all as specified and directed. | 6 | Each Job | 1,950 ₹11,700 | 1,000 ₹6,000 | 2,800 ₹16,800 | 700 ₹4,200 Lowest |
| 5.00 | S&F in repair ball valves high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for 20 mm bore dia of iron/ PVC pipe (Minimum weight 210gms) complete all as specified and directed. | 280 | Each | 430 ₹1,20,400 | 500 ₹1,40,000 | 190 ₹53,200 Lowest | 250 ₹70,000 |
| 6.00 | S&F in repair ball valves high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for 25 mm bore dia of iron/ PVC pipe (Minimum weight 455gms) complete all as specified and directed. | 60 | Each | 735 ₹44,100 | 600 ₹36,000 | 245 ₹14,700 Lowest | 300 ₹18,000 |
| 7.00 | S&F in repair Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed for 25 mm bore dia of iron/ PVC pipe complete all as specified and directed. | 50 | Each | 1,430 ₹71,500 | 800 ₹40,000 | 520 ₹26,000 | 450 ₹22,500 Lowest |
| 8.00 | S&F 15 mm bore dia unplasticised PVC pipes as per ASTM-D-1785 Sch 40 with pressure rating 10 kgf/cm2 including all necessary fittings fixed complete to walls, ceilings or in floors etc., any type of pipe including taking up or down old unserviceable steel tubing/ PVC pipes and connections, complete all as specified and directed. | 90 | Running Metre | 140 ₹12,600 | 200 ₹18,000 | 125 ₹11,250 Lowest | 300 ₹27,000 |
Tender Value
₹12.0 L
EMD Value
₹24,000
Closing Date
16 Feb 2026, 6:00 pmClosed
Garrison Engineer Army Trivandrum
Office of Garrison Engineer Army, Thirumala Post, Trivandrum- 695006
CLEANING OF SERVICE TANKS AND REPAIR/REPLACEMENT OF FLOAT VALVES/GATE VALVES AND SERVICE TANK AT PMS UNDER GE (ARMY) TRIVANDRUM
2026_MES_751091_1
8346/E8
Open Tender
Civil Works - Others
Item Rate
180 days
Trivandrum
As per tender documents
8 documents required · 8 mandatory
₹500
Yes
GE Army Trivandrum
₹24,000
24 Mar 2026
3 Feb 2026
18 Feb 2026
3 Feb 2026
16 Feb 2026
11 Feb 2026
3 Feb 2026 - 7 Feb 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L for tank cleaning and sterilization of inside the RCC/ PVC water tanks of capacity exceeding 200 ltrs and not exceeding 500 Ltrs capacity, by disconnecting existing tank and setting aside (or lowering if required), dewatering, for repairs, cleaning, sterilization using TERBAC G5/ Inchlor-5/ NB-10/ TERBAC-G-65/ Inoxi-60/ NB-69 and Ultra violet ray : Make: Rays cleantech/ Inus water tech/ Satya enterprises and removing the dirt, sediments, scale, algae formation from inside of tank and removing from site including writing mentioning "TANK CLEANED ON" with date, month and year and hoisting if required reconnecting and re-fixing in position complete all as specified and directed with the following cleaning process of the tanks:- | 835 | Each Job | 1.25 | ₹1,043.75 |
| 1.01 | (a) First stage: To drain out the water by using exist valve or high capacity dewatering system.
(b) Second stage: Cleaning all the algae from inside the tank by using TERBAC G-10/ Inoxi-60/ NB-69 lab tested branded chemicals and scrubbing the walls of the tank by scrubber.
(c) Third stage: Fresh water cleaning with high speed jet pump.
(d) Fourth stage: First bacteria screening is decertification by using TERBAC G5/ INCHLOR-5/ NB-10 a Govt. lab certified branded halogen compound of E-in-C approved equivalent product.
(e) Fifth stage: Cleaning the floor of the water tank with heavy duty industrial vacum cleaner.
(f) Sixth stage: Second bacteria screening and sterilization method using ultra violet ray within the tank for killing all suspected bacteria.
(g) Seventh stage: Cleaning and third bacteria screening and sterilization of the tank floorby using lab tested branded chemiclasstrong oxidizing agent TERBAC-G-65/ Inoxi-60/ NB-69 or E-in-C approved equivalent product. | - | - | - | - |
| 2 | All as per Sl No. 1.00 here-in-before, but water tanks of capacity exceeding 500 ltrs and not exceeding 1000 ltrs complete all as specified and directed. | 160 | Each Job | - | - |
| 3 | All as per Sl No. 1.00 here-in-before, but water tanks of capacity exceeding 1000 ltrs and not exceeding 2000 ltrs complete all as specified and directed. | 20 | Each Job | 100 | ₹2,000 |
| 4 | All as per Sl No. 1.00 here-in-before, but water tanks of capacity exceeding 2000 ltrs and not exceeding 5000 ltrs complete all as specified and directed. | 6 | Each Job | 53 | ₹318 |
| 5 | S&F in repair ball valves high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for 20 mm bore dia of iron/ PVC pipe (Minimum weight 210gms) complete all as specified and directed. | 280 | Each | 10 | ₹2,800 |
| 6 | S&F in repair ball valves high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for 25 mm bore dia of iron/ PVC pipe (Minimum weight 455gms) complete all as specified and directed. | 60 | Each | 11 | ₹660 |
| 7 | S&F in repair Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed for 25 mm bore dia of iron/ PVC pipe complete all as specified and directed. | 50 | Each | - | - |
| 8 | S&F 15 mm bore dia unplasticised PVC pipes as per ASTM-D-1785 Sch 40 with pressure rating 10 kgf/cm2 including all necessary fittings fixed complete to walls, ceilings or in floors etc., any type of pipe including taking up or down old unserviceable steel tubing/ PVC pipes and connections, complete all as specified and directed. | 90 | Running Metre | 100 | ₹9,000 |
| 9 | All as per Sl No. 8.00 here-in-before, but 20mm bore dia complete all as specified and directed. | 90 | Running Metre | 53 | ₹4,770 |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.24 MB
BOQ_841212.xls
BOQ • 0.33 MB
8346Tender.pdf
Tender Documents • 0.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .