Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.4 LAccepted-AOC 361 BEHIND DAV SCHOOL JAWAHAR NAGAR SRINAGAR 190008 | SRINAGAR | JAMMU AND KASHMIR | 190008 | L1 | Accepted-AOC Lowest bidder and quoted reasonable rate | |
| 2 | L2₹13.8 L+₹41,972 (3.13%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder |
Tender Value
₹12.2 L
EMD Value
₹24,440
Closing Date
14 Sept 2023, 6:00 pmClosed
Garrision Engineer, Kargil
GE Kargil, PIN - 908121, C/o 56 APO
CA NO. GE-K-23-2023-24 PROVN OF STORE ROOM FOR OXYGEN PLANT FOR ICU AND OT AT MH KARGIL AND PROVN OF 02 X TOILET CUM BATHROOM FOR POST NO. 01 AND 02 AT HQ 121(I) INF BDE GP CAMP UNDER GE KARGIL
2023_MES_612944_1
GE/K-23/2023-24
Open Tender
Civil Works
Item Rate
180 days
Kargil
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE Kargil
₹24,440
10 Oct 2023
9 Aug 2023
21 Sept 2023
9 Aug 2023
14 Sept 2023
24 Aug 2023
Amount
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits,manholes, pier holes, etc. n exc 10 sq m on plan and n exc1.5 m in depth and getting out in hard dense soil complete all as specified & directed.
All as per item No. 1 above but depth exc 1.50m but not exc 3.0m complete all as specified and directed.
M&L PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundations, mass filling, sub base and the like all as specified.
M&L for Precast cement concrete type-C-1 block masonary with solid blocks 1:3:6 (using 20mm graded crushed stone aggregate) exc. 10cm in width and setting in cement mortar (1:6), complete all as specified and directed by Engr-in-Charge.
Returning filling in including spreading leveling, watering and well ramming in layers not exc 25 cm in hard/dense soil complete all as specified and directed.
Removing excavated material n exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
M&L for hardcore with broken stone or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified & directed.
M & L for 100 mm thick plain cement concrete 1:3:6. type C-2 (using 40mm graded stone aggregate) as in subbase to flooring and as in plinth protection without using extra cement complete all as specified & directed.
M & L for coloured non-skid ceramic tiles 7 to 8mm thick ( square / rectangle) area of each tile exc 0.06 sqm but not exc 0.11 sqm in floors etc set and set and jointed in neat cement slurry and pointed in white or coloured cement to match the work including 15mm thick screed bed in CM ( 1:6) complete all as specfied and directed.
M & L for coloured glazed ceramic tiles in vertical surfaces 450X 350X 7mm thick, set & jointed in neat cement slurry and pointed in coloured cement to match coloured tiles laid over and including 15mm thick rendering in CM (1:4) complete all as specfied and directed.
M&L rendering 15mm thick cement plaster in cement mortar (1:6) finished even & smooth without using extra cement on brick/concrete surfaces.
M&L rendering 15mm thick cement plaster in cement mortar (1:4) finished even & fair without using extra cement on brick/concrete surfaces.
M&L for two coats of oil bound distemper on newly plastered surfaces of walls including preparation of surfaces.
M&L for two coats of cement based paint on newly plastered surfaces of walls including preparation of surfaces.
M&L for two coats of oil bound distemper on newly plastered surfaces of walls over a coat of primer including preparation of surfaces.
M&L for two coats of cement based paint on newly plastered surfaces of walls over a coat of primer including preparation of surfaces.
M&L for precast cement concrete type B-1 (1:2:4) using 20mm graded stone aggregates as in lintels, landings, coverslabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in CM 1:4 complete all as specified..
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, ending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed.
All as per item no 13 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified & directed.
S & F MS structural steel work for roof trusses, pulines, rails, fastening, bracket, framing, beams, tee, angle, channels etc including distance pieces, cleat etc of Fe 410 W grade E -250 complete all as specified and directed.
S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified & directed.
S&F Steel ventilator with top hung shutter including hinges, steel peg stay, complete all as directed.
S&F 3mm thick figured glass ordinary quality and glazing fixed with oil putty in square not exc 0.5 Sqm in each pane complete all as specified and directed.
M & L for preparation of new or previously untreated steel surfaces of any description over 10cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer described complete all as specified and directed.
S & F solid PVC door frame of size 50 mm x 47 mm made out of 5mm thick PVC sheet reinforced with mild steel square tube complete all as directed.
S & F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing complete all as per specification and directed.
S&F aluminum anodized ‘D’ type handles 125 mm complete all as specified and directed .
S&F 150 mm aluminium anodised barrel tower bolts of extruded section complete all as specified and as directed.
S & F 100 mm Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 complete all as specified and as directed.
S&F 16mm outer diameter 3-layer PP-R (polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc complete all as specified and directed.
All as per item no. 25 above but 25mm outer diameter.
S&F 25mm dia PP-R Gate valves (brass insert) as per requirement of the site complete all as specified and directed.
S & F 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S & F 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S & F 110 mm bore PVC (SWR) bends with oval access door any radius complete all as specified and directed.
S & F 75 mm bore PVC (SWR) bends with oval access door any radius complete all as specified and directed.
S & F 110 mm bore PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed.
S & F 75 mm bore PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed.
S&F 75mm bore PVC (SWR) reducers complete all as specified and directed.
S&F 75 mm bore PVC (SWR) vent cowl complete all as specified and directed.
S&F 75mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed.
S&F 10 ltrs capacity PVC valveless syphonic action type low level flushing cistern complete with syphone handle lever PVC bend including connecting to WC and fixing on walls with bracket all as specified
S&F vitreous china wash hand basin (flat black) white of size 550x400mm with pedestal excluding taps, waste chain and plug and porcelain stopper including a pair of mild steel angle iron brackets of suitable size complete all as specified.
S&F 32mm dia Waste coupling of CP brass for WHB including waste pipe complete all as specified.
S & F stainless steel squatting pan of pattern “long pan”, size 580 x 440 mm with ‘P’ or ‘S” trap, front or back inlet and foot rests, any pattern (excluding flushing cistern and flush pipe) complete all as specified.
S&F 15mm bore PVC connection 600mm long both ends screwed with brass cap all as specified
S & F 15 mm dia Bib taps, chromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S&F 15mm bore dia angle valves, fancy type chromiun plated cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F 15mm bore Pillar taps fancy type, chromiun plated cast copper alloy, screwed down, high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed.
S&F brass CP tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified.
S&F 1000 ltr capacity rotationally moulded polythene water storage tanks (cylindrical vertical with closed top) multilayers layers of approved make hoisted & fixed at position.
M & L for 75 mm thick plain cement concrete 1:3:6. type C-2 (using 40mm graded aggregate) as in plinth protection complete all as specified and directed.
M&L for M-25 grade cement concrete using 20mm graded stone aggregates as in Foundations, including rafts,footings, foundation beams, plinth beams; bases for columns, etc. basement slabs,under-reamed piles and mass concrete complete all as specified & directed.
M&L for M-25 grade cement concrete using 20mm graded stone aggregates as in Beams, cantilevers, bressummers,lintels over 1.5m span complete all as specified & directed.
M&L for M-25 grade cement concrete using 20mm graded stone aggregates as in Columns, pillars, piers, posts and struts complete all as specified & directed.
M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter surface finished fair complete all as specified & directed.
M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc surface finished fair complete all as specified & directed.
M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions surface finished fair complete all as specified & directed.
S&F MS Plates (plain or chequered) channels, square cut or notched(ordinary and counter sunk)forming holes with riveted, bolted or welded attachment Fe-410- W(Gde-E-250) quality- B complete all as specified and directed.
S&F Mild steel bolts exc 12mm but n.exc 20mm dia of neck purpose made with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut exc 30cm long complete all as specified and directed.
S&F 4mm thick sheet glass ordinary quality and glazing fixed with oil putty in square not exc 0.5 Sqm in each pane complete all as specified and directed.
M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified & directed.
M&L for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete incl 20mm thick screed bed in CM 1:4 complete all as specified and directed
S&F 1.25mm thick gear operated type Steel rolling shutters with bevel gear box and crank handle, without ball bearing, as specified including top cover, anchoring rod, hasp and staple, locking arrangement and one shop coat of primer; erected in position as indicated complete all as specified and directed
M&L for stone masonry walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, bulit in cement mortar 1:4, complete all as specified & directed.
M&L for stone masonry walling of random rubble,uncoursed, well bonded, laid dry in retaining walls, abutments and similar work complete all as specified & directed.
M&L for point wiring for light/fan/bell with FRLS cable 1.5 sqmm PVC insulated (red for phase and black for neutral) unsheathed, multi stranded copper conductor 1100 volt grade in and incl not less than 2mm thick PVC casing/caping with all accessories and 1.5 sqmm green in colour PVC multistranded, copper conductor FRLS cable for earth continuity connected to common earth dolly incl MS sunken box with 3 mm thick pre laminated hylem sheet/PVC box, surface/ flush type for mounting fittings such as switches, sockets, fan regulators etc complete all as specified and directed for one light/fan /bell point controlled by one switch & making good to disturbed surface of wall etc all as specified and directed.
M&L for Point wiring complete with 2.5 Sq mm (nominal area) PVC insulated flame retardent low smoke un-sheathed and multicore copper conductor cable with colour code ISI marked in and including PVC concealed conduit ISI marked and conduit fittings for 5 amp socket point on independent board including PVC insulated 2.5 Sqmm single core copper earth wire to common earth and connecting to earth dolly and including suitable GI sunken box of suitable size and covered with & including 3 mm thick bakelite, laminated hylem sheet top cover etc,complete all as specified.(cost of GI sunken box, bakelite sheet is included in overall cost quoted).
M&L for Point wiring complete with 2.5 Sq mm (nominal area) PVC insulated flame retardent low smoke un-sheathed and multicore copper conductor cable with colour code ISI marked in and including PVC concealed conduit ISI marked and conduit fittings for 15 amp socket point on independent board including PVC insulated 2.5 Sqmm single core copper earth wire to common earth and connecting to earth dolly and including suitable GI sunken box of suitable size and covered with & including 3 mm thick bakelite, laminated hylem sheet top cover etc,complete all as specified.(cost of GI sunken box, bakelite sheet is included in overall cost quoted).
Supply and fixing Switch piano flush type single pole one way, 5/6 Amps, ISI Marked fixed on laminated sheet top cover (laminated sheet top cover is included in point wiring) complete all as specified and directed.
S&F Switch socket combination 2 in 1, 6A flush type
S&F Switch socket combination 2 in 1, 3 pin, 6 and 16 Amp flush type universal
S&F of Lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings.
S&F LED 9 watt bulb 230 volts,complete all as specified and as directed.
Supply and fixing Ceiling rose, surface bakelite 2 to 3 terminal, 240 volts, 5 Amps ISI Marked complete ,all as specified.
Supply & Fixing LED complete fitting 1 x 18/20 Watt, appx 4 feet long extruded polycarbonate environment friendly and aluminium housing & integrated driver, including electric connection with using 2 core flexible copper conductor cable of size 1.0sqmm from ceiling rose to tube fitting, complete fitting with all accessories and following specifications all as directed. (a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt. (b) Input Voltage range : 140 to 270 volts. (c) Temp operating range : Minus 10 C to plus 45 C (d) Power factor : Minimum 0.95 (e) THD : Max 10% (f) IP rating IP- 20. (g) Aluminium housing & Integrated Electronic driver (h) LED Driver of the make as of the luminire. (j) LED driver should be complete with all protections viz open/short protection, over voltage protection, all as per standard design of manufacture. (k) Surge protection minimum 2.5 KV. (l) CCT 6500K (m) CRI : More than 80. (n) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily).
Supply and fixed TPN Distribution Board Vertical type 4 way double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with powder coating flushl/surface mounting with copper bus bar rating 250 Amps, with two neutral bar, 2 earth bar and cable tie for cable management, IP-43 Protection and provision and including MCCB 4 pole 63Amp,16KA as incomer and MCBs as outgoing, dust and vermin proof complete as per IEC61439-3 complete all as directed. Note : MCB'S For outgoing shall be measured and paid seperately.
M&L for Distribution Board double Door 4 way SPN made out of CRCA mild steel sheet surface with insulated material like polyester or with powder coating surface mounting with bus bar rating 200 Amps, dust and vermin proof , IP-43 protected, suitable for incorporation of MCB’s and isolators etc complete all as specified and directed.
Supply and fixing 220V 10KA 'C' curve MCB SPN of 32 amps current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed..
Supply and fixing 415V 10KA 'C' curve MCB TPN of 32 amps current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed..
Supply and fixing 415V 10KA 'C' curve MCB TP of 32 amps current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed..
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed.
M&L for Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6.3mm thick, buried directly in ground vertically (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 meter below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers made out of galvanised iron or steel and connected to main switch board or equipement,including watering arrangement with GI light grade 20mm bore watering pipe with funnel and wire mesh with PCC chamber.CI cover with frame,40 mm dia GI pipe light grade for protection of earthing lead etc including necessary excavation in any type of strata,returning,filling,removal of soil outside MD land,filling of charcoal and salt complete all as shown in electrical plate No.3 of MES Sch Part I,connected to Earthing test point all as specified and directed on testing on completion. Notes: (i) Earth continuity conductor including protection pipe up to 7.5 metres from earth electrode will be include in unit rate,complete all as specified and directed. (ii) Arrangement for earth resistance test should be carried out by the contractor.no extra payment shall be provided for the same.
S&F Changeover switch on load of capacity 63 A, 415 Volts, 4 pole, with metal enclosure box complete all as specified and directed.
M&L for submain wiring comprising single core ,4 Runs of 6 sqmm nominal cross sectional area multi stranded FRLS copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including PVC casing caping of size min 2 mm thick, ISI Marked and its fittings in floor/roof/walls complete including provision of 1X6 sqmm nominal cross sectional area multi stranded FRLS copper conductor cable, PVC insulated unsheathed 1100 Volts grade as earth wire and using color code as per IS complete all as specified and directed. Note : 1 Meter of casing caping including fitting and 3 Runs of single core cable shall be measured as Unit Runing Meter.Additional wire/cable required for connecting to MCB shall be included in overall cost quoted.
M&L for submain wiring comprising single core ,2 Runs of 6 sqmm nominal cross sectional area multi stranded FRLS copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including PVC casing caping of size min 2 mm thick, ISI Marked and its fittings in floor/roof/walls complete including provision of 1X6 sqmm nominal cross sectional area multi stranded FRLS copper conductor cable, PVC insulated unsheathed 1100 Volts grade as earth wire and using color code as per IS complete all as specified and directed. Note : 1 Meter of casing caping including fitting and 3 Runs of single core cable shall be measured as Unit Runing Meter.Additional wire/cable required for connecting to MCB shall be included in overall cost quoted.
Sand cushioning with fine sand to under ground cables in trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable as specified in clause 19.75 of SSR Part-I, complete all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover, class LV, Type I, flat, size 250 mm x 150mm x 40mm laid dry over electric cable for protection,complete all as specified and directed.
Supply & fixing light grade GI Pipe of size 40 mm bore, ISI marked on pole/wall for cable protection complete all as specified and directed.
Supply & Fixing energy efficient LED building security light fitting of 35 W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street/Roadway luminaire, with driver including electric connection using 3 core PVC insulated overall sheathed flexible copper cable of 1.5sqmm, complete fitting with all accessories and following specifications all as directed. (a) Lumen system efficacy of` luminaire should be minimum 110 Lumen per watt. (b) Input Voltage range : 140 to 270 volts. (c) Temp operating range : Minus 10 C to plus 50 C (d) Power factor : Minimum 0.95 (e) THD : Max 10% (f) CRI : morethan 80 and CCT : 5700K. (g) IP rating : IP66. (h) IK rating : Minimum IK 07 (j) Built in potted LED Driver of the make as of the luminaire. (k) LED driver should be complete with all protections viz open/short protection, over voltage protection, all as per standard design of manufacture. (l) Surge protection 5 KV (inbuilt + extended) (m) Lens - High Efficiency wide angle lens. (n) BIS Approved fixtures and driver. (o) Rated life time : 50000 burning hrs (Average 10 to 12 hrs daily).
Supply and fixing of street light bracket made out of GI pipe 32 mm dia light grade 1.2 meter duly bent in position as per site requirement and including 2 Nos and 2 set MS flat iron clamps of suitable size complete with Nut , bolts and washers for mounting street lights, complete all as specified and directed.
S&F 1100 volts grade heavy duty 10 sqmm 2 core flat cable PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 01 metre apart including 4 mm suspension complete all as specified and directed.
M&L of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 25 sq. mm 4 core complete all as specified and directed.
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm.
Note :Deduction for amount of Rs 0.00 as listed in Schedule A Part - II ( Schedule of Credit) shall be made offline while awarding of contract.
M/S MOHD SADIQ
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .