Loading…
Loading…
| # | Company | Amount | Status |
|---|---|---|---|
| 1 | M/s. Techno Electric & Engineering Company Limited ₹168.7 Cr | - | |
| 2 | Qualified | Qualified | |
| 3 | Not Qualified | Not Qualified | |
| 4 | Qualified | Qualified | |
| 5 | Qualified | Qualified |
Tender Value
Refer Docs
EMD Value
₹4.5 Cr
Closing Date
22 Mar 2019, 11:00 amClosed
Kaushalendra Singh
Power Grid Corporation of India Limited Saudamini, 3rd Floor, Plot No.-2, Sector-29 Gurgaon (Haryana) - 122001
AIS Substation Package-SS29 for 765/400 kV Bhadla-2 (Jodhpur) Substation under Transmission scheme for solar energy zones in Rajasthan, Specification No.: CC-CS/912-NR1/SS-3933/3/G10
CC-CS/912-NR1/SS-3933/3/G10 (SS29)
Open
Power/Energy Projects/Products
Works
Bhadla-2 (Jodhpur)
₹25,000
₹4.5 Cr
27 Aug 2019
8 Feb 2019
26 Mar 2019
8 Feb 2019
22 Mar 2019
8 Feb 2019
18 Feb 2019
Name of Package : AIS Substation Package-SS29 Establishment of 765/400kV Bhadla-II PS (Jodhpur) new S/S under Transmission Scheme for Solar Energy Zones in Rajasthan
Specification No. : CC-CS/912-NR1/SS-3933/3/G10 (SS-29)
Completion Period 15 Months
: Attachments : General guidelines for filling up the Attachments : Substation Package SS-29 :
AIS Substation Package-SS29 Establishment of 765/400kV Bhadla-II PS (Jodhpur) new S/S under Transmission Scheme for Solar Energy Zones in Rajasthan
Specification No.: CC-CS/912-NR1/SS-3933/3/G10 (SS-29)
1 Fill up only green shaded cells in the relevent attachments.
2 Attachments 3(JV), 3(QR), Attach QR, 4, 4(A), 4(B), 5, 5(A), 6, 7, 9, 10, 11, 12, 13, 14, 15, 16, 17,18, 19, 20,21,22,23 and Bid Form for 1st Envelope are included here.
3 Attachment 1 Bid Security : To be submitted as perproforma provided in the bidding document.
4 Attachment 2 Power of Attorney : No specific format is provided by POWERGRID. Bidder may use their own format.
5 Attachment 8 Manufacturer’s Authorisation Form : To be furnished as per proforma provided in the bidding document, on the letter head of the each Manufactures proposed to supply main items. Not included here.
6 Attachment 14 Integrity Pact : To be submitted as per ITB Clause No. 9.3(n) and as per remarks in the Attach 14-IP.
7 Attachment 18 Safety Pact : To be submitted as per ITB Clause No. 9.3(r) and as per remarks in the Attach 18.
Note : Enable the Active X Control & Macros. Also ensure to keep option of "Trust acess to VBA project object Model" cheched [√]. Ensure that you work on MS Excel 2007 or higher version.
पावर ग्रिड कारपोरेशन ऑफ इण्डिया लिमिटेड
(भारत सरकार का उद्यम)
Power Grid Corporation of India Limited
(A Government of India Enterprises)
AIS Substation Package-SS29 Establishment of 765/400kV Bhadla-II PS (Jodhpur) new S/S under Transmission Scheme for Solar Energy Zones in Rajasthan
CC-CS/912-NR1/SS-3933/3/G10 (SS-29) Sole Bidder 1
Yes JV (Joint Venture) 2 or More
Enter following details of the bidder No
Specify type of Bidder [Select from drop down menu] 0 2 0
Whether the bidder is an MSE (Micro & Small Enterprise) 0 2 2 0
Enter the Name of Registration Authority
Name of Lead Partner
Address of Lead Partner
Name of other Partner - 1
Address of other Partner - 1
Route-1 of Annexure-A(BDS)
Route-2 of Annexure-A(BDS)
Name of other Partner - 2 (more, if any) Joint venture Route
Address of other Partner - 2 (more, if any)
Specification No. :CC-CS/912-NR1/SS-3933/3/G10 (SS-29) Attachment-3(JV) 0
AIS Substation Package-SS29 Establishment of 765/400kV Bhadla-II PS (Jodhpur) new S/S under Transmission Scheme for Solar Energy Zones in Rajasthan
(Joint Venture Agreement and Power of Attorney for Joint Venture*)
Bidder’s Name and Address (Lead Partner) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
Name(s) and Addresse(s) of other partner(s)
The Joint Venture Agreement (as per the proforma attached at no. 15 in Section-VI, Sample Forms and Procedures, Conditions of Contract, Vol.-I of the Bidding Documents) and Power of Attorney for Joint Venture (as per the proforma attached at no. 14 in Section-VI, Sample Forms and Procedures, Conditions of Contract, Vol.-I of the Bidding Documents) are enclosed herewith 0
Date : -- Printed Name : 0
Place : Designation : 15
Specification No. :CC-CS/912-NR1/SS-3933/3/G10 (SS-29) Attachment-3(QR)
AIS Substation Package-SS29 Establishment of 765/400kV Bhadla-II PS (Jodhpur) new S/S under Transmission Scheme for Solar Energy Zones in Rajasthan
(Qualifying Requirement Data)
Bidder’s Name and Address (Lead Partner) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
For our Qualifying Requirements Data, please refer Schedule-QR of this volume.
Date : -- Printed Name :
Place : Designation :
Specification No. :CC-CS/912-NR1/SS-3933/3/G10 (SS-29) Attachment-4
AIS Substation Package-SS29 Establishment of 765/400kV Bhadla-II PS (Jodhpur) new S/S under Transmission Scheme for Solar Energy Zones in Rajasthan
(Form of Certificate of Origin and Eligibility)
Bidder’s Name and Address (Lead Partner) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We hereby certify that equipment and materials to be supplied are produced in [Name of Countries], eligible source country. Equipments & Materials produced in [Name of countries] Company incorporated & registered in [Name of countries]
We hereby certify that our company is incorporated and registered in [Name of Countries], eligible source country. [Name of Countries] [Name of Countries] [Name of Countries], [Name of Countries],
Date : -- Printed Name :
Place : Designation :
country. country. [Name of Countries], [Name of Countries],
Specification No. :CC-CS/912-NR1/SS-3933/3/G10 (SS-29) Attachment-4(A)
AIS Substation Package-SS29 Establishment of 765/400kV Bhadla-II PS (Jodhpur) new S/S under Transmission Scheme for Solar Energy Zones in Rajasthan
(List of Special Maintenance Tools & Tackles)
Bidder’s Name and Address (Lead Partner) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We are furnishing below the list of special maintenance tools & tackles for various equipment under the subject package. The prices for these tools & tackles are included in our lumpsum bid price. We further confirm that the list of special maintenance tools & tackles includes all the items specifically identified in your bidding documents as brought out below:
S.No. For Equipment Item Description Unit Quantity
Notwithstanding what is stated above, we further confirm that any additional special maintenance tools and tackles, required for the equipment under this package shall be furnished by us at no extra cost to the employer.
Date : -- Printed Name :
Place : Designation :
Specification No. :CC-CS/912-NR1/SS-3933/3/G10 (SS-29) Attachment-4(B)
AIS Substation Package-SS29 Establishment of 765/400kV Bhadla-II PS (Jodhpur) new S/S under Transmission Scheme for Solar Energy Zones in Rajasthan
(List of Special Maintenance Tools & Tackles)
Bidder’s Name and Address (Lead Partner) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We are furnishing below the list of special maintenance tools & tackles for various equipment under the subject package. The prices for these tools & tackles which are to be taken back after the completion of the work by us are not included in our lumpsum bid price. We further confirm that the list of special maintenance tools & tackles includes all the items specifically identified in your bidding documents as brought out below:
Date : -- Printed Name :
Place : Designation :
Specification No. :CC-CS/912-NR1/SS-3933/3/G10 (SS-29) Attachment-5
AIS Substation Package-SS29 Establishment of 765/400kV Bhadla-II PS (Jodhpur) new S/S under Transmission Scheme for Solar Energy Zones in Rajasthan
(Bought-out & Sub-contracted Items)
Bidder’s Name and Address (Lead Partner) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We hereby furnish the details of the items/ sub-assemblies, we propose to buy for the purpose of furnishing and installation of the subject Package:
Sl. No. Item Description Quantity proposed to be bought/sub-contracted Details of the proposed sub-contractor/sub-vendor
Name Nationality
We hereby declare that, we would not subcontract the erection portion of the contract without the prior approval of Employer.
We hereby furnish the details of the items/ sub-assemblies propose to supply from our own works (i.e. as direct transactions) in additiona to the supplies the same from other vendors (i.e. as Bought-out transactions) as detailed in the table given above.
Sl. No. Item Description Quantity proposed to be supplied Details of the plant from where supplies are proposed.
Name of Plant Address
Date : -- Printed Name :
Place : Designation :
Specification No. :CC-CS/912-NR1/SS-3933/3/G10 (SS-29) Annexure I to Attachment-5
(Bought-out & Sub-contracted Items)
Sl. No. Item Description Quantity proposed to be bought/sub-contracted Details of the proposed sub-contractor/sub-vendor
Name Nationality
Date : -- Printed Name :
Place : Designation :
Specification No. :CC-CS/912-NR1/SS-3933/3/G10 (SS-29) Annexure I to Attachment-5
(Bought-out & Sub-contracted Items)
Sl. No. Item Description Details of the proposed sub-contractor/sub-vendor Details of the proposed sub-contractor/sub-vendor
Name Nationality
Date : -- Printed Name :
Place : Designation :
Specification No. :CC-CS/912-NR1/SS-3933/3/G10 (SS-29) Attachment-5A
AIS Substation Package-SS29 Establishment of 765/400kV Bhadla-II PS (Jodhpur) new S/S under Transmission Scheme for Solar Energy Zones in Rajasthan
(Items, Components, Raw Material, Services proposed to be sourced from Micro and Small Enterprises)
Bidder's Name and Address: Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
1 We hereby furnish the details of the items, components, raw material, services which we propose to buy/avail from Micro and Small Enterprises (MSEs) for the purpose of completion of works under the subject package:
Sl. No. Item Description Quantity proposed to be bought/sub-contracted Name of Micro and Small Enterprises (MSEs)
Name Category (Micro or Small)
2 2. The above is a list of items we propose to procure from MSEs. However, based on the situations during the execution of the contract, the above list may undergo changes. We hereby confirm that the details regarding actual procurement from MSEs carried out by us, as per the format provided at Section VI, Forms and Procedures, Volume-I of bidding documents, shall be submitted along with the bills for payment against supplies made/works done during execution of contract.
We hereby furnish the details of the items/ sub-assemblies propose to supply from our own works (i.e. as direct transactions) in additiona to the supplies the same from other vendors (i.e. as Bought-out transactions) as detailed in the table given above.
Sl. No. Item Description Quantity proposed to be supplied Details of the plant from where supplies are proposed.
Name of Plant Address
Date : -- Printed Name :
Place : Designation :
Specification No. :CC-CS/912-NR1/SS-3933/3/G10 (SS-29) Attachment-5A
(Bought-out & Sub-contracted Items)
Sl. No. Item Description Quantity proposed to be bought/sub-contracted Name of Micro and Small Enterprises (MSEs)
Name Category (Micro or Small)
Date : -- Printed Name :
Place : Designation :
Specification No. :CC-CS/912-NR1/SS-3933/3/G10 (SS-29) Attachment-6
AIS Substation Package-SS29 Establishment of 765/400kV Bhadla-II PS (Jodhpur) new S/S under Transmission Scheme for Solar Energy Zones in Rajasthan
(Alternative, Deviations and Exceptions to the Provisions)
Bidder’s Name and Address (Lead Partner) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
The bidder shall itemize any deviation from the Specifications included in his bid. Each item shall be listed (separate sheets may be used and enclosed with this Attachment) with the following information:
Sl. No. Reference clause in the Specifications Deviation Cost of withdrawal of the deviation
The above deviations and variations are exhaustive. We confirm that we shall withdraw the deviations proposed by us at the cost of withdrawal indicated in this attachment, failing which our bid may be rejected and Bid Security forfeited.
Date : -- Printed Name :
Place : Designation :
Specification No. :CC-CS/912-NR1/SS-3933/3/G10 (SS-29) Annexure I toAttachment-6
(Alternative, Deviations and Exceptions to the Provisions)
Sl. No. Reference clause in the Specifications Deviation Cost of withdrawal of the deviation
Date : -- Printed Name :
Place : Designation :
Specification No. :CC-CS/912-NR1/SS-3933/3/G10 (SS-29) Attachment-7
AIS Substation Package-SS29 Establishment of 765/400kV Bhadla-II PS (Jodhpur) new S/S under Transmission Scheme for Solar Energy Zones in Rajasthan
(Details of Alternative Bid)
Bidder’s Name and Address (Lead Partner) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
No Alternative Bid
Date : -- Printed Name :
Place : Designation :
Specification No. :CC-CS/912-NR1/SS-3933/3/G10 (SS-29) Attachment-9
AIS Substation Package-SS29 Establishment of 765/400kV Bhadla-II PS (Jodhpur) new S/S under Transmission Scheme for Solar Energy Zones in Rajasthan
(Work Completion Schedule)
Bidder’s Name and Address (Lead Partner) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We hereby declare that the following Work Completion Schedule shall be followed by us in furnishing and installation of the subject Package i.e., AIS Substation Package-SS29 Establishment of 765/400kV Bhadla-II PS (Jodhpur) new S/S under Transmission Scheme for Solar Energy Zones in Rajasthan for the period commencing from the effective date of Contract to us :
Sl. No. Description of Work Period in months from the effective date of contract
765/400kV Bhadla-II PS (Jodhpur) new Substation
1 Detailed Engineering and drawing submission
a) commencement
2 Procurement of equipment/ components & assembly
a) commencement
a) commencement
4 Manufacturing
a) commencement
5 Shipments & Delivery
a) commencement
6 Establishment of site office
7 Installation at Site
a) commencement
8 Testing & Pre-commissioning
a) commencement
9 Trial Operation
a) commencement
Date : -- Printed Name :
Place : Designation :
Note : Bidders to enclose a detailed network covering all the activities to be undertaken for completion of the project indicating key dates for various milestones for each phase constituent-wise.
Specification No. :CC-CS/912-NR1/SS-3933/3/G10 (SS-29) Attachment-10
AIS Substation Package-SS29 Establishment of 765/400kV Bhadla-II PS (Jodhpur) new S/S under Transmission Scheme for Solar Energy Zones in Rajasthan
(Guarantee Declaration)
Bidder’s Name and Address (Lead Partner) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
Dear Sir, We conform that the equipments offered shall have minimum performance specified in Technical Specification. We further guarantee the performance/efficiency of the equipments in response to the Technical Specifications.
Date -- Printed Name :
Place : Designation :
Specification No. :CC-CS/912-NR1/SS-3933/3/G10 (SS-29) Attachment-11
AIS Substation Package-SS29 Establishment of 765/400kV Bhadla-II PS (Jodhpur) new S/S under Transmission Scheme for Solar Energy Zones in Rajasthan
(Information regarding Ex-employees of POWERGRID in our Organisation)
Bidder’s Name and Address (Lead Partner) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We declare that we are aware of and have gone through the “Code of Business Conduct and Ethics for Senior Management Personnel”1 and “Code of Business Conduct and Ethics for Board Members”1 of POWERGRID (hereinafter referred to as the “Code of Conduct”). We further understand that as per the “Code of Conduct”, Senior Management Personnel including Board Members, who have retired/resigned from POWERGRID, shall not accept any appointment or post, as detailed in the referred “Code of Conduct”, within 1 year from the date of cessation of service/directorship unless approved by the Competent Authority. Accordingly, we hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation*
*In case the date of joining in the bidder’s organization of such ex-employee is within 1 year from the date of retirement/resignation from POWERGRID, No Objection Certificate/ approval from the Competent Authority must be furnished along with the bid or subsequent through clarification pursuant to ITB Clause 21.
In case of non-submission of No Objection Certificate/approval of the Competent Authority, as required, We understand that POWERGRID shall deal with such cases as per its Policy and procedures in vogue, which may also result in rejection of our bid. We also confirm that POWERGRID shall be the sole judge in this regard. We further declare that any misrepresentation or submission of false/forged documents/information in this regard shall be dealt with as per the provisions of the Integrity Pact and/or the Bidding Documents and/or POWERGRID’s policy and procedures.
Date : -- Printed Name :
Place : Designation :
Note: 1. “Code of Business Conduct and Ethics for Senior Management Personnel” and “Code of Business Conduct and Ethics for Board Members” are available on POWERGRID’s website https://www.powergridindia.com. 2. The information in similar format should be furnished for each partner of joint venture in case of joint venture bid. 3. In case bidder has furnished no details on ex-employees of POWERGRID or has left blank or has indicated ‘-‘ against the same, it shall be deemed that they have not employed any such person in their organization.
Specification No. :CC-CS/912-NR1/SS-3933/3/G10 (SS-29) Attachment-11
AIS Substation Package-SS29 Establishment of 765/400kV Bhadla-II PS (Jodhpur) new S/S under Transmission Scheme for Solar Energy Zones in Rajasthan
(Information regarding Ex-employees of POWERGRID in our Organisation)
Name(s) and Addresse(s) of other partner(s) To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
Date : -- Printed Name :
Place : Designation :
Specification No. :CC-CS/912-NR1/SS-3933/3/G10 (SS-29) Attachment-11
AIS Substation Package-SS29 Establishment of 765/400kV Bhadla-II PS (Jodhpur) new S/S under Transmission Scheme for Solar Energy Zones in Rajasthan
(Information regarding Ex-employees of POWERGRID in our Organisation)
Name(s) and Addresse(s) of other partner(s) To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
Date : -- Printed Name :
Place : Designation :
Specification No. :CC-CS/912-NR1/SS-3933/3/G10 (SS-29) ATTACHMENT-12
AIS Substation Package-SS29 Establishment of 765/400kV Bhadla-II PS (Jodhpur) new S/S under Transmission Scheme for Solar Energy Zones in Rajasthan
(Price Adjustment Data)
Bidder’s Name and Address (Sole Bidder) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We hereby furnish the relevant details pertaining to the price adjustment provisions for equipment as specified in your specifications and documents for the the subject package. The necessary documentary evidence is enclosed.
Sl. No. Name of Materials/Labour Value of co-efficient Name of the published index Value of index as 30 days prior to date set for opening of bids
In accordance with Clause 2, Appendix-2, Form of Contract Agreement, Section-VI; Forms. Volume-I
A) For Equipment Ex-Works Price Component
I. Circuit Breaker
a) Raw Material
b) Labour I= Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2001= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
The sum of the value of coefficients for raw materials: a+b+c+d=0.55 to 0.65 and sum of all the coefficients including labour shall be a+b+c+d+l=0.85.
II Current Transformer
a) Raw Material
b) Labour I= Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2001= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
The sum of the value of coefficients for raw materials: a+b+c+d=0.55 to 0.65 and sum of all the coefficients including labour shall be a+b+c+d+l=0.85.
III Capacitive VoltageTransformer
a) Raw Material
b) Labour I= Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2001= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
The sum of the value of coefficients for raw materials: a+b+c+d=0.55 to 0.65 and sum of all the coefficients including labour shall be a+b+c+d+l=0.85.
a) Raw Material
b) Labour I= Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2001= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
The sum of the value of coefficients for raw materials: a+b+c+d=0.55 to 0.65 and sum of all the coefficients including labour shall be a+b+c+d+l=0.85.
V Surge Arrester
a) Raw Material
b) Labour I= Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2001= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
The sum of the value of coefficients for raw materials: a+b+c+d=0.55 to 0.65 and sum of all the coefficients including labour shall be a+b+c+d+l=0.85.
VI PVC/XLPE Insulated Power and Control Cable
a) a=PVC Compound 0.15
b) Published Price of Metal IEEMA
i) Aluminium per MT IEEMA
ii) Copper per MT IEEMA
c) Weight in MT of Metal per kM (Size wise)
VII Substation Structures
i) Lattice Steel Structures & Pipe Structures (including bolts & nuts, washers & foundation bolts)
a) Raw Materials
i) a=Structural steel 0.58 JPC Market Price (Retail) for average Price of Steel Angles of size 50 x 50 x 6 mm of all cities in Rs./MT as published by Joint Plant Committee(JPC).
ii) b=Electrolytic Zinc 0.16 IEEMA
b) Labour 0.11 Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2001= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
VIII. Power Transformer [53.33MVA, 220/33kV, & 53.33MVA, 220/66/11kV, 1-Phase Power Transformers] without Insulating oil:
a) Raw Material
i) Copper a= Price of Copper wire bars, in Rupees per MT, as published by IEEMA.
ii) Electrical Lamination Steel b= Price of CRGO Electrical Steel Sheets: C&F Price converted into Indian Rupees per MT for Transformer of rating above 10MVA or voltage above 33kV, as published by IEEMA.
iii) Construction Steel c= Wholesale Price Index Number for `Manufacture of Basic Metals’(Group Item) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in), as published by IEEMA
iv) Insulating Material d= Price of Insulating Materials , as published by IEEMA.
b) Labour I= Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2001= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
The sum of the value of coefficients for raw materials: a+b+c+d=0.65 to 0.73 and value of coefficient for labour shall be between 0.12 and 0.20, so that sum of all the coefficients including labour shall be a+b+c+d+l=0.85
IX. Insulating oil for Power Transformer:
a) Insulating Oil e= 0.85 Transformer Oil (TO): Transformer oil conforming to IS:335-1993, supplied in drum(Ex-Refinery, Mumbai) as published by IEEMA.
X. L. T. Transformer[630kVA, 11/0.433kV, and 630kVA, 33/0.433kV, 3ph LT Transformer]:
a) Raw Material
i) Copper a= Price of Copper wire bars, in Rupees per MT, as published by IEEMA.
ii) Electrical Lamination Steel b= Price of CRGO Electrical Steel Sheets: C&F Price converted into Indian Rupees per MT for Transformer of rating up to 10MVA and voltage up to 33kV, as published by IEEMA.
iii) Construction Steel c= Wholesale Price Index Number for `Manufacture of Basic Metals’(Group Item) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in), as published by IEEMA
iv) Insulating Material d= Price of Insulating Materials , as published by IEEMA.
v) Insulating Oil e= Transformer Oil Base Stock (TOBS): (TB), as published by IEEMA
b) Labour I= Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2001= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
The sum of the value of coefficients for raw materials: a+b+c+d+e =0.65 to 0.73 and value of coefficient for labour shall be between 0.12 and 0.20, so that sum of all the coefficients including labour shall be a+b+c+d+e+l=0.85
B. For Installation Price Component
I Installation price component (including Civil works but excluding ‘supply & placement of reinforcement steel’ and ‘concreting’)
i) Labour I= 0.80 Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2001= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
II Supply & Placement of Reinforcement Steel
i) HSD 0.10 Wholesale Price Index Number for `HSD’(Individual Commodity) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
ii) Labour I= 0.05 Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2001= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
iii) Manufacture of Basic Metals 0.65 Wholesale Price Index Number for `Manufacture of Basic Metals’(Group Item) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
III For Concereting
i) HSD 0.20 Wholesale Price Index Number for `HSD’(Individual Commodity) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
ii) Labour I= 0.10 Indian field labour index – namely All India average consumer price index for Industrial Workers (monthly) (Base: 2001= 100), as published by Labour Bureau, Shimla, Government of India (www.labourbureau.nic.in).
iii) Manufacture of cement, lime and plaster 0.30 Wholesale Price Index Number for `Manufacture of cement, lime and plaster’(Group Item) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry (www.eaindustry.nic.in)
iii) Cutting, shaping and finishing of stone 0.20 Wholesale Price Index Number for `Cutting, shaping and finishing of stone’(Group Item) (monthly) (Base: 2011-12=100), as published by Office of Economic Advisor, Ministry of Commerce & Industry(www.eaindustry.nic.in).
The Bidders are required to estimate and indicate the values of different coefficients for each of the items in the price variation formulae within the specified range such that their summation is as specified in the Bidding Documents. Where no value or ‘-’ or ‘shall be furnished later’ is specified against the coefficient, the same will be deemed to be zero and the fixed component would be suitably adjusted. If the values of all coefficients in price variation formulae indicated by the Bidder are within the specified range but their sum exceeds the summation specified in the Bidding Documents, the values of the coefficients shall be pro-rata adjusted such that the summation remains as per the provisions of the Bidding Documents. If the values of all coefficients indicated by the Bidder are within the specified range but their summation is less than the value specified in the Bidding Documents, the values of the coefficients as indicated by the Bidder shall be considered as such and the fixed component in the price variation formulae would be suitably adjusted. Further, if any of values of the coefficients indicated by the Bidder is out of the range specified in the Bidding Documents, the lower of the values, as indicated by the Bidder vis-à-vis lower value of the range for that coefficient specified in the Bidding Documents, shall be considered and the fixed component would be suitably adjusted.
Date : -- Printed Name :
Place : Designation :
Specification No. :CC-CS/912-NR1/SS-3933/3/G10 (SS-29) Attachment-13
AIS Substation Package-SS29 Establishment of 765/400kV Bhadla-II PS (Jodhpur) new S/S under Transmission Scheme for Solar Energy Zones in Rajasthan
(Declaration regarding Social Accountability)
Bidder’s Name and Address (Lead Partner) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We conform that we stand committed to comply to all requirements of Social Accountability Standards i.e., SA8000 (latest Standard available at www.sa-intl.org) and maintain the necessary records.
Date : -- Printed Name :
Place : Designation :
Specification No. :CC-CS/912-NR1/SS-3933/3/G10 (SS-29) Attachment-14
AIS Substation Package-SS29 Establishment of 765/400kV Bhadla-II PS (Jodhpur) new S/S under Transmission Scheme for Solar Energy Zones in Rajasthan
Bidder’s Name and Address (Lead Partner) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
Integrity Pact is annexed herewith this Volume.
Date : -- Printed Name :
Place : Designation :
Instruction for printing & submitting Integrity Pact
1. The requisite format of Integrity Pact is getting generated automatically and displayed here below.
2. Take print out of first page on a non-judicial stamp paper of Rs. 100/- and other seven pages on plain A4 size paper. Such two sets shall be prepared by the bidder.
3. All the pages of both the copies of the Integrity Pact shall be signed by the authorised representative of the bidder and duly stamped.
4. Both the original copies shall be submitted by the bidder in the form of Hard Copy as part of the first envelope before due date & time of submission of the bid.
5. For further details bidders may please refer ITB Clause 9.3 (o).
Power Grid Corporation of India Limited
having its Registered Office at B-9, Qutab Institutional Area, Katwaria Sarai,New Delhi – 110016 hereinafter referred to as
having its Registered Office at
having its Registered Office at FALSE
hereinafter referred to as
"The Bidder/Contractor"
POWERGRID intends to award, under laid-down organisational procedures, contract(s) for AIS Substation Package-SS29 Establishment of 765/400kV Bhadla-II PS (Jodhpur) new S/S under Transmission Scheme for Solar Energy Zones in Rajasthan
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 1 of 8
AIS Substation Package-SS29 Establishment of 765/400kV Bhadla-II PS (Jodhpur) new S/S under Transmission Scheme for Solar Energy Zones in Rajasthan Package and Specification Number CC-CS/912-NR1/SS-3933/3/G10 (SS-29) POWERGRID values full compliance with all relevant laws and regulations, and the principles of economical use of resources, and of fairness and transparency in its relations with its Bidders/ Contractors.
In order to achieve these goals, POWERGRID and the above named Bidder/Contractor enter into this agreement called 'Integrity Pact' which will form a part of the bid.
It is hereby agreed by and between the parties as unde r:
Section I - Commitments of POWERGRID
(1) POWERGRID commits itself to take all measures necessary to prevent corruption and to observe the following principles :
a) No employee of POWERGRID, personally or through family members, will in connection with the tender, or the execution of the contract, demand, take a promise for or accept, for him/herself or third person, any material or other benefit which he/she is not legally entitled to.
b) POWERGRID will, during the tender process treat all Bidder(s) with equity and fairness. POWERGRID will in particular, before and during the tender process, provide to all Bidder(s) the same information and will not provide to any Bidder(s) confidential/ additional information through which the Bidder(s) could obtain an advantage in relation to the tender process or the contract execution.
c) POWERGRID will exclude from evaluation of Bids its such employee(s) who has any personnel interest in the Companies/Agencies participating in the Bidding/Tendering process.
(2) If Chairman and Managing Director obtains information on the conduct of any employee of POWERGRID which is a criminal offence under the relevant Anti-Corruption Laws of India, or if there be a substantive suspicion in this regard, he will inform its Chief Vigilance Officer and in addition can initiate disciplinary actions under its Rules.
Section II - Commitments of the Bidder/Contractor
(1) The Bidder/Contractor commits himself to take all measures necessary to prevent corruption. He commits himself to observe the following principles during his participation in the tender process and during the contract execution :
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 2 of 8
a) The Bidder/Contractor will not, directly or through any other person or firm, offer, promise or give to POWERGRID, or to any of POWERGRID's employees involved in the tender process or the execution of the contract or to any third person any material or other benefit which he/she is not legally entitled to, in order to obtain in exchange an advantage during the tender process or the execution of the contract.
b) The Bidder/Contractor will not enter into any illegal agreement or understanding, whether formal or informal with other Bidders/Contractors. This applies in particular to prices, specifications, certifications, subsidiary contracts, submission or non-submission of bids or actions to restrict competitiveness or to introduce cartelization in the bidding process.
c) The Bidder/Contractor will not commit any criminal offence under the relevant Anti-corruption Laws of India; further, the Bidder/Contractor will not use for illegitimate purposes or for purposes of restrictive competition or personal gain, or pass on to others, any information provided by POWERGRID as part of the business relationship, regarding plans, technical proposals and business details, including information contained or transmitted electronically.
d) The Bidder/Contractor of foreign origin shall disclose the name and address of the Agents/representatives in India, if any, involved directly or indirectly in the Bidding. Similarly, the Bidder/Contractor of Indian Nationality shall furnish the name and address of the foreign principals, if any, involved directly or indirectly in the Bidding.
e) The Bidder/Contractor will, when presenting his bid, disclose any and all payments he has made, or committed to or intends to make to agents, brokers or any other intermediaries in connection with the award of the contract and/or with the execution of the contract.
f) The Bidder/Contractor will not misrepresent facts or furnish false/forged documents/informations in order to influence the bidding process or the execution of the contract to the detriment of POWERGRID.
(2) The Bidder/Contractor will not instigate third persons to commit offences outlined above or be an accessory to such offences.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 3 of 8
Section III- Disqualification from tender process and exclusion from future contracts
(1) If the Bidder, before contract award, has committed a serious transgression through a violation of Section II or in any other form such as to put his reliability or credibility as Bidder into question, POWERGRID may disqualify the Bidder from the tender process or terminate the contract, if already signed, for such reason.
(2) If the Bidder/Contractor has committed a serious transgression through a violation of Section II such as to put his reliability or credibility into question, POWERGRID may after following due procedures also exclude the Bidder/Contractor from future contract award processes. The imposition and duration of the exclusion will be determined by the severity of the transgression. The severity will be determined by the circumstances of the case, in particular the number of transgressions, the position of the transgressors within the company hierarchy of the Bidder/Contractor and the amount of the damage. The exclusion will be imposed for a minimum of 12 months and maximum of 3 years.
(3) If the Bidder/Contractor can prove that he has restored/recouped the damage caused by him and has installed a suitable corruption prevention system, POWERGRID may revoke the exclusion prematurely.
Section IV - Liability for violation of Integrity Pact
(1) If POWERGRID has disqualified the Bidder from the tender process prior to the award under Section III, POWERGRID may forfeit the Bid Guarantee under the Bid.
(2) If POWERGRID has terminated the contract under Section III, POWERGRID may forfeit the Contract Performance Guarantee of this contract besides resorting to other remedies under the contract.
Section V- Previous Transgression
(1) The Bidder shall declare in his Bid that no previous transgressions occurred in the last 3 years with any other Public Sector Undertaking or Government Department that could justify his exclusion from the tender process.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 4 of 8
(2) If the Bidder makes incorrect statement on this subject, he can be disqualified from the tender process or the contract, if already awarded, can be terminated for such reason.
Section VI - Equal treatment to all Bidders / Contractors
(1) POWERGRID will enter into agreements with identical conditions as this one with all Bidders.
(2) POWERGRID will disqualify from the tender process any bidder who does not sign this Pact or violate its provisions.
Section VII - Punitive Action against violating Bidders / Contractors
If POWERGRID obtains knowledge of conduct of a Bidder or a Contractor or his subcontractor or of an employee or a representative or an associate of a Bidder or Contractor or his Subcontractor which constitutes corruption, or if POWERGRID has substantive suspicion in this regard, POWERGRID will inform the Chief Vigilance Officer (CVO).
(*)Section VIII - Independent External Monitor/Monitors
(1) POWERGRID has appointed a panel of Independent External Monitors (IEMs) for this Pact with the approval of Central Vigilance Commission (CVC), Government of India, out of which one of the IEMs has been indicated in the NIT/IFB.
(2) The IEM is to review independently and objectively, whether and to what extent the parties comply with the obligations under this agreement. He has right of access to all project documentation. The IEM may examine any complaint received by him and submit a report to Chairman-cum-Managing Director, POWERGRID, at the earliest. He may also submit a report directly to the CVO and the CVC, in case of suspicion of serious irregularities attracting the provisions of the PC Act. However, for ensuring the desired transparency and objectivity in dealing with the complaints arising out of any tendering process, the matter shall be referred to the full panel of IEMs, who would examine the records, conduct the investigations and submit report to Chairman-cum-Managing Director, POWERGRID, giving joint findings.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 5 of 8
(3) The IEM is not subject to instructions by the representatives of the parties and performs his functions neutrally and independently. He reports to the Chairman-cum-Managing Director, POWERGRID.
(4) The Bidder(s)/Contractor(s) accepts that the IEM has the right to access without restriction to all documentation of POWERGRID related to this contract including that provided by the Contractor/Bidder. The Bidder/Contractor will also grant the IEM, upon his request and demonstration of a valid interest, unrestricted and unconditional access to his documentation. The same is applicable to Subcontractors. The IEM is under contractual obligation to treat the information and documents of the Bidder(s)/Contractor(s)/Subcontractor(s) with confidentiality.
(5) POWERGRID will provide to the IEM information as sought by him which could have an impact on the contractual relations between POWERGRID and the Bidder/Contractor related to this contract.
(6) As soon as the IEM notices, or believes to notice, a violation of this agreement, he will so inform the Chairman-cum-Managing Director, POWERGRID and request the Chairman-cum-Managing Director, POWERGRID to discontinue or take corrective action, or to take other relevant action. The IEM can in this regard submit non-binding recommendations. Beyond this, the IEM has no right to demand from the parties that they act in a specific manner, refrain from action or tolerate action. However, the IEM shall give an opportunity to POWERGRID and the Bidder/Contractor, as deemed fit, to present its case before making its recommendations to POWERGRID.
(7) The IEM will submit a written report to the Chairman-cum-Managing Director, POWERGRID within 8 to 10 weeks from the date of reference or intimation to him by POWERGRID and, should the occasion arise, submit proposals for correcting problematic situations.
(8) If the IEM has reported to the Chairman-cum-Managing Director, POWERGRID, a substantiated suspicion of an offence under relevant Anti-Corruption Laws of India, and the Chairman-cum-Managing Director, POWERGRID has not, within the reasonable time taken visible action to proceed against such offence or reported it to the CVO, the Monitor may also transmit this information directly to the CVC, Government of India.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 6 of 8
(9) The word ‘IEM’ would include both singular and plural.
(*) This Section shall be applicable for only those packages wherein the IEMs have been identified in Section – I : Invitation for Bids and/or Clause ITB 9.3 in Section – III: Bid Data Sheets of Conditions of Contract, Volume-I of the Bidding Documents.
Section IX - Pact Duration
This Pact begins when both parties have legally signed it. It expires for the Contractor after the closure of the contract and for all other Bidder's six month after the contract has been awarded.
Section X - Other Provisions
(1) This agreement is subject to Indian Law. Place of performance and jurisdiction is the establishment of POWERGRID. The Arbitration clause provided in the main tender document / contract shall not be applicable for any issue / dispute arising under Integrity Pact.
(2) Changes and supplements as well as termination notices need to be made in writing.
(3) If the Contractor is a partnership firm or a consortium or Joint Venture, this agreement must be signed by all partners, consortium members and Joint Venture partners.
(4) Nothing in this agreement shall affect the rights of the parties available under the General Conditions of Contract (GCC) and Special Conditions of Contract (SCC).
(5) Views expressed or suggestions/submissions made by the parties and the recommendations of the CVO/IEM# in respect of the violation of this agreement, shall not be relied on or introduced as evidence in the arbitral or judicial proceedings (arising out of the arbitral proceedings) by the parties in connection with the disputes/differences arising out of the subject contract.
# CVO shall be applicable for packages wherein IEM are not identified in Section IFB/BDS of Condition of Contract, Volume-I. IEM shall be applicable for packages wherein IEM are identified in Section IFB/BDS of Condition of Contract, Volume-I.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 7 of 8
(6) Should one or several provisions of this agreement turn out to be invalid, the remainder of this agreement remains valid. In this case, the parties will strive to come to an agreement to their original intentions.
Signature Signature
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
(Office Seal) (Office Seal)
Designation : Designation :
Witness 1 : Witness 1 :
Designation : Designation :
Witness 2 : Witness 2 :
Designation : Designation :
Integrity Pact Page 8 of 8
Specification No. :CC-CS/912-NR1/SS-3933/3/G10 (SS-29) Attachment-15
AIS Substation Package-SS29 Establishment of 765/400kV Bhadla-II PS (Jodhpur) new S/S under Transmission Scheme for Solar Energy Zones in Rajasthan
Option for Initial Advance (either Interest Bearing Initial Advance or No Initial Advance) and Information for E – payment, PF details and declaration for Micro/Small and Medium Enterprise
Bidder’s Name and Address (Lead Partner) : Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
I We have read the provisions in the Bidding Documents regarding furnishing the option for advance payment. Accordingly, as per ITB Clause 9.3 as provided in Section BDS, Section III, Vol.-I of the Bidding Documents, we hereby confirm to opt the following:
Interest Bearing Initial Advance
Supply Portion:
Services Portion:
II We are furnishing the following details of Statutory Registration Numbers and details of Bank for electronic payment.
1. Name of the Supplier/ Contractor in whose favour payment is to be made
2. Address with PIN Code and State
Registered Office:
Correspondence Address:
3. (a) Status – Company/others
[Declaration of Micro/ Small/ Medium Enterprise under Micro/ Small & Medium Enterprises Development Act 2006, if applicable]
3. (b) Are you a MSE owned by SC/ST* entrepreneurs in line with Public Procurement Policy for Micro and Small Enterprises (MSEs) order 2012 including subsequent amendment/notification/order (Indicate Yes/No) Note: Documentary evidence is to be attached. Please refer remarks at the end of the attachment.
3. (c ) If 3(b) is ‘Yes’ please mention whether you are (Proprietary MSE/ Partnership MSE/ Private Limited Company) owned by SC/ST entrepreneurs
3. (d ) Are you a MSE owned by women in line with Public Procurement Policy for Micro and Small Enterprises (MSEs) order 2012, Public Procurement Policy for Micro and Small Enterprises (MSEs) Amendment order 2018 including subsequent amendment/notification/order (Indicate Yes/No) Note: Documentary evidence is to be attached.
4. Permanent Account (PAN) No.
5. GSTIN Numbers
I. GSTIN in the Sates/UT from where the supply of goods take place
Name of the States/UT GSTIN number
II. GSTIN in the States/UT where the supply for services take place (states where sites under the subject package is situated)
Name of the States/UT GSTIN number
6 PF Registration No. of the Company
7 PF Regional Office covered (with Address)
8 Name of Contact Person
9 Contact Details
10 Bank Details for Electronic Payment
Name of the Bank:
Address of Branch:
Type of Account:
Type of Account: Current Account
11 9 digit MICR code printed at bottom in middle, next to cheque no.
12 IFSC (for RTGS)/NEFT Code (to be obtained from the Bank) Sample Cancelled Cheque to be enclosed
We hereby declare that the above information are true and correct and we agree that the payment on account of this Contract, in the event of award, be made in the above account maintained in the above mentioned Bank.
*The definition of MSEs owned by SC/ST is as given under:
a. In case of proprietary MSE, proprietor(s) shall be SC /ST.
b. In case of partnership MSE, the SC/ST partners shall be holding at least 51% shares in the unit.
c. In case of Private Limited companies, at least 51% share shall be held by SC/ST promoters.
Documentary evidence: Please provide scanned copy(ies) of the SC/ST certificate(s) issued by District Authority as applicable for SC/ST MSE category as per (a), (b) or (c) above.
Date : -- Printed Name :
Place : Designation :
Specification No. :CC-CS/912-NR1/SS-3933/3/G10 (SS-29) Attachment-16
AIS Substation Package-SS29 Establishment of 765/400kV Bhadla-II PS (Jodhpur) new S/S under Transmission Scheme for Solar Energy Zones in Rajasthan
(Additional Information)
Bidder’s Name and Address (Lead Partner) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
In support of the additional information required as per ITB Sub-Clause 9.3 (p) of the Bidding Documents, we furnish herewith our data/details/documents etc., alongwith other information, as follows (the stipulations have been reproduced in italics for ready reference):
1.0 The Bidder shall furnish
A certificate from their Banker(s) (as per prescribed formats in Form 16, Section-VI: Sample Forms and Procedures) indicating various fund based/non fund based limits sanctioned to the Bidder and the extent of utilization as on date. Such certificate should have been issued not earlier than three months prior to the date of bid opening. Wherever necessary the Employer may make queries with the Bidders’ Bankers. [Reference ITB clause 9.3(p)(i)]
1.1 In accordance with 1.0, certificate(s) from banker as per requisite format, indicating various fund based/non fund based limits sanctioned to the bidder or each member of the joint venture and the extent of utilization as on date is/are enclosed, as per the following details:
Name of Bidder (Lead Partner)
Name of the Banker by whom certificate issued
Date of certificate (should not be earlier than 3 months prior to date of bid opening)
Whether fund based/non fund based limits are indicated in the certificate
Whether extent of utilization is indicated in the certificate
1.2 The Bidder should accordingly also provide the following information/documents
(i) Details of Banker:
Address of Banker
Contact Name and Title
(ii) As per para 1.0, Authorization Letter(s) from the bidder (in case of JV bidder, from all the partners) addressed to the Banker(s), authorizing POWERGRID to seek queries about the bidder with the Banker(s) and advising the Banker(s) to reply the same promptly, is/are enclosed as per following details:
Sl. No. Letter Ref. Date Addressed to (name of the Bank)
2.0 Litigation History
The bidder should provide detailed information on any litigation or arbitration arising out of contracts completed or under execution by it over the last five years. A consistent history of awards involving litigation against the Bidder or any partner of JV may result in rejection of Bid. [Reference ITB clause 9.3(p)(ii)]
2.1 Details of litigation history resulting from Contracts completed or under execution by the bidder over the last five years
Year Name of client, cause of litigation/arbitration and matter in dispute Details of Contract and date Award for or against the bidder Disputed amount
3.0 OTHER INFORMATION
3.1 Current Contract Commitments of works in progress
Bidders (individual firms or each partners of JV) should provide information on their current commitments on all contracts that have been awarded, or for which a letter of intent or acceptance has been received, or for contracts approaching completion, but for which an unqualified, full completion certificate has yet to be issued.
Details of Contract Value of outstanding work (Rs.) Estimated completion date
3.2 Financial Data:
Details Actual (Previous five years) Projection for next five years
Total Liability
Current Liability
Profit before taxes
Profit after taxes
4.0 Details of Provident Fund Code Number of the Bidder [ref. ITB9.3(q)]
Date : -- Printed Name :
Place : Designation :
Specification No. :CC-CS/912-NR1/SS-3933/3/G10 (SS-29) Attachment-17
AIS Substation Package-SS29 Establishment of 765/400kV Bhadla-II PS (Jodhpur) new S/S under Transmission Scheme for Solar Energy Zones in Rajasthan
(Declaration for tax exemptions, reductions, allowances or benefits)
Bidder’s Name and Address (Lead Partner) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
1 We confirm that we are solely responsible for obtaining following tax exemptions, reductions, allowances or benefits in respect of supplies under the subject package, in case of award. We further confirm that we have considered the same in our bid thereby passing on the benefit to POWERGRID while quoting our prices. In case of our failure to receive such benefits, partly or fully, for any reason whatsoever, the Employer will not compensate us.
2 We are furnishing the following information required by the Employer for issue of requisite certificate if and as permitted in terms of the applicable Govt. of India policies/procedures (in case of award):
Applicable Act, Notification No. and Clause Ref. No. Sl. No. Description of item on which applicable Country of origin Remarks, if any
(The requirements listed above are as per current Notification of Govt. of India indicated above. These may be modified, if necessary, in terms of the Notifications.)
Date : -- Printed Name :
Place : Designation :
Specification No. :CC-CS/912-NR1/SS-3933/3/G10 (SS-29) Attachment-17
AIS Substation Package-SS29 Establishment of 765/400kV Bhadla-II PS (Jodhpur) new S/S under Transmission Scheme for Solar Energy Zones in Rajasthan
(Information regarding Ex-employees of POWERGRID in our Organisation)
Name(s) and Addresse(s) of other partner(s) To:
Contract Services
Name : …… ……. …….. …… ……. …….. Power Grid Corporation of India Ltd.,
Address : …… ……. …….. …… ……. …….. "Saudamini", Plot No. 2, Sector 29
We hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
Date : -- Printed Name :
Place : Designation :
Specification No. :CC-CS/912-NR1/SS-3933/3/G10 (SS-29) Attachment-17
AIS Substation Package-SS29 Establishment of 765/400kV Bhadla-II PS (Jodhpur) new S/S under Transmission Scheme for Solar Energy Zones in Rajasthan
(Information regarding Ex-employees of POWERGRID in our Organisation)
Name(s) and Addresse(s) of other partner(s) To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
Date : -- Printed Name :
Place : Designation :
Specification No. :CC-CS/912-NR1/SS-3933/3/G10 (SS-29) Attachment-18
AIS Substation Package-SS29 Establishment of 765/400kV Bhadla-II PS (Jodhpur) new S/S under Transmission Scheme for Solar Energy Zones in Rajasthan
Bidder’s Name and Address (Lead Partner) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
Safety Pact is attached herewith this Volume
Date : -- Printed Name :
Place : Designation :
Instruction for printing & submitting Safety Pact
1. The requisite format of Safety Pact is getting generated automatically and displayed here below.
2. Take print out of first page on a non-judicial stamp paper of Rs. 100/- and other six pages on plain A4 size paper. Such two sets shall be prepared by the bidder.
3. All the pages of both the copies of the Safety Pact shall be signed by the authorised representative of the bidder and duly stamped.
4. Both the original copies shall be submitted by the bidder in the form of Hard Copy as part of the first envelope before due date & time of submission of the bid.
5. For further details bidders may please refer ITB Clause 9.3 (s).
Between #REF! #REF!
Power Grid Corporation of India Limited #REF! #REF!
having its Registered Office at B-9, Qutab Institutional Area, Katwaria Sarai, New Delhi – 110016 hereinafter referred to as #REF! #REF!
"POWERGRID", #REF! #REF!
0 1 having its Registered Office at ,
having its Registered Office at ,, 1 AND
having its Registered Office at FALSE
hereinafter referred to as
"The Bidder/Contractor"
POWERGRID intends to award, under laid-down organisational procedures, contract(s) forAIS Substation Package-SS29 Establishment of 765/400kV Bhadla-II PS (Jodhpur) new S/S under Transmission Scheme for Solar Energy Zones in Rajasthan Specification Number:CC-CS/912-NR1/SS-3933/3/G10 (SS-29)
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Safety Pact Page 1 of 6
POWERGRID values full compliance with all relevant laws and regulations and the principles of Safety, Health& Environment in its relations with its Bidders/ Contractors.
In order to achieve these goals, POWERGRID and the above named Bidder / Contractor enter into this agreement called “Safety Pact” which will form part of the Bid.
It is hereby agreed by and between the parties as under:
Section I - Commitments of POWERGRID
POWERGRID commits itself to take all measures necessary to prevent accidents duringConstruction and Operation of the Transmission Assets and to observe the following:
1. POWERGRID recognizes and accepts its statutory responsibilities for ensuring construction, operation and maintenance of equipments and for the provision of safe methods of work and safe working conditions.
2. POWERGRID recognizes and accepts its statutory responsibilities for ensuring safety of not only its employees but also that of the Contracting Agencies as Principal Employer.
3. POWERGRID shall review the accidents in a structured manner and take necessary actions to ensure that the safety criteria are strengthened for safe construction as well as Operation & Maintenance of the Transmission Assets.
4. POWERGRID shall conduct necessary awareness and training programmes to its Employees to augment the various safety requirements to be followed during Construction and Operation & Maintenance of the Transmission Assets from time to time.
5. POWERGRID shall, from time to time, issue necessary guidelines,instructions and deterrents to its employees as well as to the Contracting Agencies, to update them to take necessary preventive measures to avoid repetition of similar accident attributes.
6. POWERGRID shall review and provide necessary guidanceto the Contracting Agencies, as and when, any abnormality / special situations are brought to its notice by the Contracting Agencies during execution of the Transmission Projects being executed by them.
7. POWERGRID shall conduct periodical surveillance site inspections / audits to identify the unsafe conditions and unsafe actions, and bring them to the knowledge of the Contracting Agencies for taking timely corrective actions.
8. POWERGRIDshall investigate all accidents, fatal as well as non-fatal, to identify the lapses, the reason for the accident / incident and suggest measures for prevention of recurrence of such accidents, and fix responsibility for the lapses leading to the accident.
9. POWERGRID shall augment the training to the workers and supervising personnel of the Contracting Agencies, as per schedules, upon nomination by the Contracting Agencies in reasonable time frame.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Safety Pact Page 2 of 6
10. POWERGRID shall exercise the right to claim and recover compensation from the Contracting Agencies in case of any violation of the safety requirements / provisions during execution of the Transmission Projects, as built in the applicable Laws and contractual specifications / guidelines in vogue / issued by POWERGRID from time to time.
Section II – Commitments of the Bidder / Contractor:
The Bidder / Contractor commits himself to take all measures necessary to prevent / minimise accidents at their construction / erection sites and to observe the following:
1. The Bidder / Contractor recognizes and acceptsthe statutory and comprehensive responsibility for ensuring safe construction and Testing & Commissioning in the Transmission Projects being executed by thembyproviding safe methods of work, working conditions and Tools & Plants for human safety.
2. The Bidder / Contractor recognizes and accepts the responsibilities for ensuring safety of not only their employees but also that of the Sub-contractors, Principal Employer and the general public during execution of the Transmission Projects / works.
3. The Bidder / Contractor shall review the accidents in a structured manner and take necessary actions to ensure that the safety criteria are strengthened for safe construction of the Transmission Assets.
4. The Bidder / Contractor shall endeavour continuous development of safe methods of work to ensure that the effect of risks and perils are minimised to the extent possible and implement the same at their worksites.
5. The Bidder / Contractor shall conduct periodical Training to their Employees as well as to that of theirSub-contractors for safety awareness during construction works being executed by them.
6. The Bidder / Contractor shall provide all requisite Tools & Plants required for the work and ensure their healthiness by periodical inspections / testing as required. Unhealthy and sub-standard Tools & Plants will be immediately removed from site as and when they are identified.
7. The Bidder / Contractor shall,at their cost, provide all necessary Personal Protective Equipments such as Double Lanyard Safety Belts, Appropriate Fall Arrest Systems, Safety Helmets, Foot Wear, Hand Gloves, etc., as required for various activities pertaining to execution of the Projects / works, confirming to relevant Indian Standards.
8. The Bidder / Contractor shall ensure that dedicated qualified Safety Officers are posted in the construction projects being executed by them and ensure that the Safety Officer visits each and every gang periodically and conducts audits / inspections to identify the unsafe conditions and unsafe actions, to be rectified by the site supervising personnel promptly.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Safety Pact Page 3 of 6
9. The Bidder / Contractor shall conduct appropriate medical checks-up for the workers before deploying them at their construction sites to ensure that only those who are medically fit are deployed in the Projects / works to be executed by them. The copy of the Medical Reports shall be provided by the Bidder / Contractor to POWERGRID, whenever requested by POWERGRID.
10. The Bidder / Contractor shall screen the workers before deploying them at their construction sites to ensure that only those with the skills, experience and competence to work at heightand also medically fitfor work at height are deployed for work at height in the Projects executed by them.
11. The Bidder / Contractor shall ensure daily before starting the work thattheir site Supervising Personnel / Safety Officer briefs the workers about the work for the day and the safety measures / precautions required to be taken by them.
12. The Bidder / Contractor shall investigate all the accidents at their working sites to ascertain the lapses leading to the incident and the precautionary / corrective measures required to be taken to avoid recurrence of such accidents. These accidents will be reviewed at the Board Management level of the Agencies and the findings / recommendations will be put up to POWERGRID Apex Safety Board within the stipulated period.
13. The Bidder / Contractor shall ensure that all accidents, whether fatal or non-fatal in nature, will be informed to POWERGRID, in writing, immediately on the occurrence of the same,and in any case, within not more than 24 hours of occurrence of the same.
14. The Bidder / Contractor shall ensure that in case of any accident, all necessary medical help / supportshall be provided to the victims / injured till they are completely fit to return to work.
15. The Bidder / Contractorshall ensure that in case of fatal accidents, all statutory Authorities, including Police, concerned Labour Dept. Officials, concerned Workmen Compensation Commissioner, etc., will be intimated in writing as required by the statutory Law, and followed up for compliance of all statutory obligations. The Bidder / Contractor shall own full responsibility of timely accident reporting to various authorities, including POWERGRID.
16. The Bidder / Contractor shall ensure that in case of fatality or serious injury leading to permanent disablement of the victims, the compensation amount will be deposited with the concerned authorities, as required by the Laws, and followed up for early disbursement to the beneficiaries of the victims.
17. The Bidder / Contractor assures that they shall co-operate to the fullest extent for carrying out any investigation of the accidents at their work sites by POWERGRID to identify the lapses, the reason for the accident / incident and suggest measures for prevention of recurrence of such accidents. All factual details of the occurrence of the accident will be provided to POWERGRID, as and when required.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Safety Pact Page 4 of 6
18. The Bidder / Contractor assures that they take full responsibility of meeting the statutory obligations in case of accidents, and in case of any reference by any Statutory Body at a later date also, they shall provide all information to POWERGRID and meet all the statutory obligations, including payment of additional compensation, if any.
19. The Bidder / Contractor assures that in case of any inspection of their work site or Notice by any Statutory Authority, they shall comply promptly and inform POWERGRID Site Officials of the same, and also provide all necessary information and assistance for smooth compliance of the observations / instructions of such Authorities.
20. The Bidder / Contractor accepts the provisions regarding safety, including payment of compensation to POWERGRID, in case of any violation of the safety requirements / provisions during execution of the Transmission Projects, as built in the Contractual Conditions, Safety Planand the Safety Pact, and confirm to abide by the same.
Section III – Equal treatment to all Bidders / Contractors:
1. POWERGRID will enter into agreements with identical conditions as this one with all Bidders.
2. POWERGRID will disqualify, from the tender process, any bidder/ take punitive actions on the bidder, who does not sign this Pact or violate its provisions.
Section IV – Pact Duration:
This Pact begins when both parties have legally signed it. It expires for the successful Bidder / Contractor after closure of the contract and, for all other Bidders, after the contract has been awarded.
Section V – Other Provisions:
1. This agreement is subject to Indian Law. Place of performance and jurisdiction is the establishment of POWERGRID. The Arbitration clause provided in the main tender document / contract shall not be applicable for any issue / dispute arising under the Safety Pact.
2. Changes and supplements need to be made in writing, which shall come into force only upon mutual agreement / acceptance.
3. If the Contractor is a partnership firm or consortium of Joint Venture, this agreement must be signed by all partners, consortium members and Joint Venue partners, as applicable as per the Tender Specifications.
4. Nothing in this agreement shall affect the rights of the parties available under General Conditions of Contract (GCC) and Special Conditions of Contract (SCC).
5. Should one or several provisions of this agreement turn out to be invalid, the reminder of this agreement remains valid. In this case, the parties will strive to come to an agreement to their original intentions.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Safety Pact Page 5 of 6
Signature Signature
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
(Office Seal) (Office Seal)
Designation : Designation :
Witness 1 : Witness 1 :
Designation : Designation :
Witness 2 : Witness 2 :
Designation : Designation :
Safety Pact Page 6 of 6
Specification No. :CC-CS/912-NR1/SS-3933/3/G10 (SS-29) Attachment-19
AIS Substation Package-SS29 Establishment of 765/400kV Bhadla-II PS (Jodhpur) new S/S under Transmission Scheme for Solar Energy Zones in Rajasthan
Bidder’s Name and Address (Lead Partner) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
Further, we hereby confirm that except as mentioned in the Attachment – 6 (Alternative, Deviations and Exceptions to the Provisions) hereof forming part of our First Envelope :
Date : -- Printed Name :
Place : Designation :
Specification No. :CC-CS/912-NR1/SS-3933/3/G10 (SS-29) Bid Form 1st Envelope 1 one 1 st 1 January
2 two 2 nd 2 February
BID FORM (First Envelope) 3 three 3 rd 3 March
4 four 4 th 4 April
Bid Proposal Ref. No. 5 five 5 th 5 May
Date : -- 6 six 6 th #VALUE! 6 June
7 seven 7 th #VALUE! 7 July
To: 8 eight 8 th #VALUE! 8 August
Contract Services 9 nine 9 th #VALUE! 9 September
Power Grid Corporation of India Ltd., 10 ten 10 th 10 October
"Saudamini", Plot No. 2, Sector 29 11 eleven 11 th 11 November
Gurgaon (Haryana) - 122001 12 twelve 12 th 12 December
13 thirteen 13 th
14 fourteen 14 th
Name of Contract : AIS Substation Package-SS29 Establishment of 765/400kV Bhadla-II PS (Jodhpur) new S/S under Transmission Scheme for Solar Energy Zones in Rajasthan 15 fifteen 15 th
Dear Ladies and/or Gentlemen, Enter details here. 16 sixteen 16 th
1.0 Having examined the Bidding Documents, including Amendment Nos. ...[Enter the Amendment]… dated …[Enter the Date in dd-mm-yyyy]… the receipt of which is hereby acknowledged, we the undersigned, offer to design, manufacture, test, deliver, install and commission (including carrying out Trial operation, Performance & Guarantee Test as per the provision of Technical Specification) the Facilities under the above-named package in full conformity with the said Bidding Documents. In accordance with ITB Clause 9.1 of the Bidding Documents, as per which the bid shall be submitted by the bidder under “Single Stage - Two Envelope” procedure of bidding. Accordingly, we hereby submit our Bid, in two envelopes i.e. First Envelope – Techno – Commercial Part & Second Envelope - Price Part (to be opened subsequently). ...[Enter the Amendment]… …[Enter the Date in dd-mm-yyyy]… the receipt of which is hereby acknowledged, we the undersigned, offer to design, manufacture, test, deliver, install and commission (including carrying out Trial operation, Performance & Guarantee Test as per the provision of Technical Specification) the Facilities under the above-named package in full conformity with the said Bidding Documents. In accordance with ITB Clause 9.1 of the Bidding Documents, as per which the bid shall be submitted by the bidder under “Single Stage - Two Envelope” procedure of bidding. Accordingly, we hereby submit our Bid, in two envelopes i.e. First Envelope – Techno – Commercial Part & Second Envelope - Price Part (to be opened subsequently). 17 seventeen 17 th
1.1 We meet the eligibility requirements and have no conflict of interest in accordance with ITB Clause 2.
2.0 Attachments to the Bid Form (First Envelope) Bank Draft 18 eighteen 18 th
In line with the requirement of the Bidding Documents, we enclose herewith the following Attachments: Enter details here. Pay Order 19 nineteen 19 th
or documentary evidence in support of exemption of Bid Security, in separate envelope in accordance with clause 21 of ITB, Section-II."
(b) Attachment 2: A power of attorney duly authorized by a Notary Public indicating that the person(s) signing the bid have the authority to sign the bid and thus that the bid is binding upon us during the full period of its validity in accordance with the ITB Clause 14. Please note that if bid validity is less than 06 (six) months, your bid may be rejected Bank Guarantee (0) 21 st
(c) Attachment 3 : The documentary evidence that we are eligible to bid in accordance with ITB Clause 2. Further, in terms of ITB Clause 9.3 (c) & (e), the qualification data has been furnished as per your format enclosed with the bidding documents Attachment-3(QR). 1 22 th
Further, the required Joint Venture Agreement signed by us and our Partners has also been furnished as per your format Attachment-3(JV). #REF! Applicable 23 th
Further the required deed of Joint Undertaking signed by us and Tower Manufacturer has also been furnished as per your format. 0 #REF! Not Applicable 24 th
(d) Attachment 4 : The documentary evidence establishing in accordance with ITB Clause 3, Vol.-I of the Bidding Documents that the facilities offered by us are eligible facilities and conform to the Bidding Documents has been furnished as Attachment 4. A list of Special Tools & Tackles to be used by us for erection, testing & Commissioning and to be handed over to Employer, the cost of which is included is our Bid Price, is also enclosed as per your format as Attachment 4A. A list of Special Tools & Tackles to be brought by the contractor for erection, testing & Commissioning and to be taken back after completion of work, whose cost in not included in our bid price, is enclosed as per your format as Attachment 4B. 25 th
(e) Attachment 5 : The details of all major items of services or supply which we propose subletting in case of award, giving details of the name and nationality of the proposed subcontractor/sub-vendor for each item. 26 th
(f) Attachment 5A : Items, Components, Raw Material, Services proposed to be sourced from Micro and Small Enterprises
(g) Attachment 6 : The variation and deviations from the requirements of the Conditions of Contract, Technical Specification and Drawings (excluding critical provisions as mentioned at clause 6.0 below) in your format enclosed with the Bidding Documents, including, inter alia, the cost of withdrawal of the variations and deviations indicated therein. 27 th
(h) Attachment 7 : The details of Alternative Bids made by us indicating the complete Technical Specifications and the deviation to contractual and commercial conditions. (Not Applicable) 28 th
(i) Attachment 8 : Manufacturer’s Authorisation Forms. 29 th
(j) Attachment 9 : Work Completion Schedule. 30 th
(k) Attachment 10 : Guarantee Declaration. 31 st
(l) Attachment 11 : Information regarding ex-employees of Employer in our firm.
(m) Attachment 12 : Filled up information regarding Price Adjustment Data as per the format enclosed in the bidding documents.
(n) Attachment 13 : Declaration regarding Social Accountability.
(o) Attachment 14 : Integrity Pact, in a separate envelope, duly signed on each page by the person signing the bid.
(p) Attachment 15 : Option for Initial Advance (either Interest Bearing Initial Advance or No Initial Advance) and Information for E – payment, PF details and declaration for Micro/Small and Medium Enterprise
(q) Attachment 16 : Additional Information.
(r) Attachment 17 : Declaration for tax exemptions, reductions, allowances or benefits
(s) Attachment 18 : Safety Pact
(t) Attachment 19 : Declaration.
(u) Attachment 20 : Declaration of Key Managerial Person jointly with Power of Attorney holder
(v) Attachment 21: Affidavit of Self certification regarding Minimum Local Content in line with PPP-MII order, if applicable
(u) Attachment 22: Certificate from statutory auditor or cost auditor of the company (in the case of companies) or from a practicing cost accountant or practicing chartered accountant (in respect of suppliers other than companies) giving the percentage of Local Content, in line with PPP-MII order, if applicable
(x) Attachment 23: Compliance to the process related to the e-RA Terms & Conditions and the Business Rules governing the e-RA
3.0 We are aware that, in line with Clause No. 27.1 (ITB), our Second Envelope (Price Part) is liable to be rejected in case the same contains any deviation/omission from the contractual and commercial conditions and technical Specifications other than those identified in this First Envelope.
4.0 We confirm that except as otherwise specifically provided our Bid Prices in Second Envelope include all taxes, duties, levies and charges as may be assessed on us, our Sub-Contractor/Sub-Vendor or their employees by all municipal, state or national government authorities in connection with the Facilities, in and outside of India.
4.1 100% of applicable Taxes and Duties i.e. GST, which are payable by the Employer under the Contract, shall be reimbursed by the Employer on production of satisfactory documentary evidence by the Contractor in accordance with the provisions of the Bidding Documents.
4.3 We confirm that we have also registered/we shall also get registered in the GST Network with a GSTIN, in all the states where the project is located and the states from which we shall make our supply of goods.
5.0 Construction of the Contract
5.1 We declare that we have studied Clause GCC 2.1 relating to mode of contracting for Domestic Bidders and we are making this proposal with a stipulation that you shall award us two separate Contracts viz ‘First Contract’ for ex-works supply of all equipment and materials including mandatory spares and ‘Second Contract’ for providing all the services i.e. inland transportation for delivery at site, In-transit insurance, unloading, handling at site, installation, testing and commissioning including Trial operation in respect of all the equipment supplied under the ‘First Contract’ and other services specified in the Contract Documents. We declare that the award of two contracts, will not, in any way, dilute our responsibility for successful operation of plant/equipment and fulfillment of all obligations as per Bidding Documents and that both the Contracts will have a cross-fall breach clause i.e. a breach in one Contract will automatically be classified as a breach of the other contract which will confer on you the right to terminate the other contract at our risk and cost.
6.0 We have read the provisions of following clauses and confirm that the specified stipulations of these clauses are acceptable to us:
(a) ITB 13 Bid Security
(b) GCC 2.14 Governing Law
(c) GCC 8 Terms of Payment
(d) GCC 9.3 Performance Security
(e) GCC 10 Taxes and Duties
(f) GCC 21.2 Completion Time Guarantee
(g) GCC 22 Defect Liability
(h) GCC 23 Functional Guarantee
(i) GCC 25 Patent Indemnity
(j) GCC 26 Limitation of Liability
(k) GCC 38 Settlement of Disputes
(l) GCC 39 Arbitration
(m) Appendix 2 to Form of Contract Agreement Price Adjustment
Further we understand that deviation taken in any of the above clauses by us may make our bid non-responsive as per provision of bidding documents and be rejected by you.
7.0 We undertake, if our bid is accepted, to commence the work immediately upon your Notification of Award to us, and to achieve the delivery of goods and related services within the time stated in the Bidding Documents.
8.0 If our bid is accepted, we undertake to provide a Performance Security in the form and amounts, and within the times specified in the Bidding Documents.
9.0 We agree to abide by this bid for a period of six (06) months from the date fixed for opening of bids as stipulated in the Bidding Documents, and it shall remain binding upon us and may be accepted by you at any time before the expiration of that period.
10.0 Until a formal Contract is prepared and executed between us, this bid, together with your written acceptance thereof in the form of your Notification of Award shall constitute a binding contract between us.
11.0 We understand that you are not bound to accept the lowest or any bid you may receive.
12.0 # (For Joint Venture only) We, the partners of Joint Venture submitting this bid, do agree and confirm that in case of Award of Contract on the Joint Venture, we shall be jointly and severally liable and responsible for the execution of the Contract in accordance with Contract terms and conditions. 2
13.0 We are a Micro and Small Enterprise (MSE) registered with , a designated Authority of GoI under the Public Procurement Policy for MSEs order 2012. 2
14.0 We, hereby, declare that only the persons or firms interested in this proposal as principals are named here and that no other persons or firms other than those mentioned herein have any interest in this proposal or in the Contract to be entered into, if the award is made on us, that this proposal is made without any connection with any other person, firm or party likewise submitting a proposal is in all respects for and in good faith, without collusion or fraud.
Thanking you, we remain,
Yours faithfully,
For and on behalf of
Date : -- Printed Name :
Place : Designation :
In case of bid from a Joint Venture, name & designation of representative of JV partner is to be provided and Bid Form is also to be signed by him
#REF! Printed Name :
#REF! Designation :
Please provide additional information of the Bidder
Business Address :
Country of Incorporation :
State/Province to be indicated :
Name of Principal Officer :
Address of Principal Officer :
23 Twenty Three
27 Twenty Seven
28 Twenty Eight
33 Thirty Three
37 Thirty Seven
38 Thirty Eight
73 Seventy Three
74 Seventy Four
75 Seventy Five
77 Seventy Seven
78 Seventy Eight
79 Seventy Nine
83 Eighty Three
87 Eighty Seven
88 Eighty Eight
93 Ninety Three
97 Ninety Seven
98 Ninety Eight
100 One Hundred
Package Name AIS Substation Package-SS29 Establishment of 765/400kV Bhadla-II PS (Jodhpur) new S/S under Transmission Scheme for Solar Energy Zones in Rajasthan
Specification No. CC-CS/912-NR1/SS-3933/3/G10 (SS29)
CC-CS/912-NR1/SS-3933/3/G10 (SS29)
1 Fill up only green shaded cells in Sch-1, Sch-2, Sch-3, Sch-4, Sch-7 and Bid Form 2nd Envelope.
2 All the cells in Sch-5 & Sch-6 are auto filled, therefore no cell is required to be filled up there.
3 Instructions / error messages, if any, will be displayed automatically after selecting the cell.
4 After filling up all the schedues, save the file, take print out of all the schedules and Bid form and sign & stamp and submit them as hard copy of the 2nd envelope (Price part) of the bid. Also ensure to submit the soft copy of the the same file on CD/ DVD.
पावर ग्रिड कारपोरेशन ऑफ इण्डिया लिमिटेड
(भारत सरकार का उद्यम)
Power Grid Corporation of India Limited
(A Government of India Enterprises)
I While filling up the worksheets following may please be observed :
(i) Fill up only green shaded cells.
(ii) Certain data type entries have been restricted, such as Numeric values or limits of numeric values.
(iii) Select only the options provided in pull down menus.
(iv) Do not link any cell of this work book with any other work book.
(v) Do not use copy & paste or cut & paste options for filling up the data.
(vi) Do not reformat any of the cell of the work book.
II This Workbook consists of following worksheets :
Opening page of the workbook.
Names of Bidder :
● Select Sole Bidder or JV (Joint Venture) from the pull down menu. Do not leave this cell blank.
● Select nos. of the JV Partners other than the Lead Partner from drop down menu.
● In case of JV partners more than 2, enter details of 3rd & more partners along with details of 2nd partner.
● Fill up names and address of the Sole Bidder and /or Joint Venture.
● Fill up date in dd-mmm-yyyy format from drop down menu.
● Click for Sch-1 given at the right top of the worksheet to go to Sch-1.
Sch-1 (Ex-works Prices) :
● Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
● Corresponding cell for mode of transaction shall be come enable only after filling up the unit rate, therefore first fill up the unit rate and then mode of transaction for the corresponding item.
● Select either Direct or Bought-out from the drop down menu. Do not leave the cell blank the same shall be deemed to be Bought-out if the cell is left blank.
● Total amount shall get calculated automatically.
● Type Test charges shall appear automatically after filling up Sch-7 appropriately.
Sch-2 (Freight & Insurance Charges) :
● Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
● Total amount shall get calculated automatically.
Sch-3 (Erection Charges) :
● Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
● Total amount shall get calculated automatically.
Sch-4 (Training Charges) :
● Not applicable, hence no cell is required to be filled up.
Sch-4b (Maintenance Charges during and after Defect Liability Period) :
● Not applicable, hence no cell is required to be filled up.
Sch-5 (Summary of Taxes and Duties applicable on the Goods) :
● No cell is required to be filled in by the bidder in this worksheet.
● Summary of all the Schedules without considering discount (mentioned in the work sheet discount) shall be displayed automatically.
● No cell is required to be filled in by the bidder in this worksheet.
Sch-7 (Type Test Charges) : NOT APPLICABLE
● Fill up the rates & location where type tests are proposed.
● Total of this Sch-7 shall automatically appear in Sch-1.
Bid from 2nd Envelope :
● Fill up ref. no. as bidder's ref no. of this letter.
● This letter shall consider the net price as per Sch-6 (After Discount).
● Fill up names & Designation of the representatives of other JV partner(s) if the bidder is JV (Joint Venture) .
● Fill up additional information as required.
Happy Bidding !
AIS Substation Package-SS29 Establishment of 765/400kV Bhadla-II PS (Jodhpur) new S/S under Transmission Scheme for Solar Energy Zones in Rajasthan
CC-CS/912-NR1/SS-3933/3/G10 (SS29) Sole Bidder 1 Sole Bidder 1
Joint Venture 2 or More JV (Joint Venture) 2 or More
Enter following details of the bidder
Specify type of Bidder [Select from drop down menu] 0 2 0 0 2 0
Name of Lead Partner
Address of Sole Bidder
Name of other Partner - 1
Address of other Partner - 1
Name of other Partner - 2 (more, if any)
Address of other Partner - 2 (more, if any)
email ID of Bid Signatory
Mobile No. of Bid Signatory
Tel No. of Bid Signatory
Fax No. of Bid Signatory
CC-CS/912-NR1/SS-3933/3/G10 (SS29) Schedule - 1 Direct Total 0 0 `
BO Total #REF! 0
AIS Substation Package-SS29 Establishment of 765/400kV Bhadla-II PS (Jodhpur) new S/S under Transmission Scheme for Solar Energy Zones in Rajasthan
(SCHEDULE OF RATES AND PRICES)
Bidder’s Name and Address (Lead Partner) : To:
Contracts Services, 3rd Floor
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Gurgaon (Haryana) - 122001
PLANT AND EQUIPMENT (INCLUDING MANDATORY SPARES PARTS) TO BE SUPPLIED, INCLUDING TYPE TEST CHARGES FOR TESTS TO BE CONDUCTED Direct
All Prices are in Indian Rupees. Bought-Out
SI. No. PR No PR Line Item No Activity Description Material Code HSN Code Whether HSN in column ‘ 6 ’ is confirmed. If not indicate applicable the HSN code * Rate of GST applicable ( in %) Whether rate of GST in column ‘8’ is confirmed. If not indicate applicable rate of GST * (in %) Item Description Unit Qty. Unit Ex-works price (excluding GST) Total Ex-works price (excluding GST) GST Tax as confirmed by Bidder
I AIS Bhadla-2 (Jodhpur) New SS Revaluation of J column Tax Calculation
1 7000009390 10 LT Transformer 1000006173 85042200 Confirmed 18 Confirmed 800kVA, 33/0.433kV, 3ph LT Transformer EA 2 Included 0.00 0 18 0.00
2 7000009390 20 800kV Equipment 1000031204 85352919 Confirmed 18 Confirmed 765KV, 3150A, 40KA CIRCUIT BREAKER WITH CLOSING RESISTOR WITHCONTROLLED SWITCHING DEVICE (WITH SUPPORT STRUCTURES) EA 2 Included 0.00 0 18 0.00
3 7000009390 30 800kV Equipment 1000005818 85352919 Confirmed 18 Confirmed 765kV, 3150A, 40KA Circuit Breaker(3-Phase) with closing resistor (withsupport structure) EA 6 Included 0.00 0 18 0.00
4 7000009390 40 800kV Equipment 1000031203 85352919 Confirmed 18 Confirmed 765KV, 3150A, 40KA CIRCUIT BREAKER WITHOUT CLOSING RESISTOR WITHCONTROLLED SWITCHING DEVICE (WITH SUPPORT STRUCTURES) EA 10 Included 0.00 0 18 0.00
5 7000009390 50 800kV Equipment 1000005855 85352919 Confirmed 18 Confirmed 765kV, 3150A, 40KA Circuit Breakerwithout closing resistor suitable for1-ph Reactor switching EA 2 Included 0.00 0 18 0.00
6 7000009390 60 800kV Equipment 1000005811 85359090 Confirmed 18 Confirmed 765 kV, 3000A, 40KA, 1-Phase CurrentTransformer with 120% extended currentrating EA 42 Included 0.00 0 18 0.00
7 7000009390 70 800kV Equipment 1000005840 85359090 Confirmed 18 Confirmed 765 kV,8800 pF Capacitive Voltage Transformer (1-Phase) EA 18 Included 0.00 0 18 0.00
8 7000009390 80 800kV Equipment 1000005850 85353090 Confirmed 18 Confirmed 765kV, 3150A, 40 KA, VerticalKnee/Double Break Isolator (3-Phase)with one E/S EA 22 Included 0.00 0 18 0.00
9 7000009390 90 800kV Equipment 1000005851 85353090 Confirmed 18 Confirmed 765kV, 3150A, 40 KA, VerticalKnee/Double Break Isolator (3-Phase)with two E/S EA 14 Included 0.00 0 18 0.00
10 7000009390 100 800kV Equipment 1000005841 85353090 Confirmed 18 Confirmed 765kV, 2000A, 40 KA, VerticalKnee/Double Break Isolator (1-Phase)with one E/S EA 27 Included 0.00 0 18 0.00
11 7000009390 110 800kV Equipment 1000005792 85353090 Confirmed 18 Confirmed 765kV, 2000A, 40 KA, VerticalKnee/Double Break Isolator (1-Phase)without E/S EA 45 Included 0.00 0 18 0.00
12 7000009390 120 800kV Equipment 1000005791 85462040 Confirmed 18 Confirmed 765 kV, 1 phase Bus Post Insulator (except for Line Traps) EA 90 Included 0.00 0 18 0.00
13 7000009390 130 800kV Equipment 1000020421 85354010 Confirmed 18 Confirmed 624kV Surge Arrester (1-Phase) EA 39 Included 0.00 0 18 0.00
14 7000009390 140 400kV Equipment 1000009711 85389000 Confirmed 18 Confirmed Controlled switching device for 420 kV, 3 phase circuit breaker SET 6 Included 0.00 0 18 0.00
15 7000009390 150 400kV Equipment 1000004489 85352913 Confirmed 18 Confirmed 420kV, 3150A, 50kA Circuit Breaker(3-Phase) without closing resistor EA 8 Included 0.00 0 18 0.00
16 7000009390 160 400kV Equipment 1000004461 85359090 Confirmed 18 Confirmed 420 kV, 3000A, 50KA, 1-Phase CurrentTransformer with 120% extended currentrating EA 24 Included 0.00 0 18 0.00
17 7000009390 170 400kV Equipment 1000004535 85359090 Confirmed 18 Confirmed 420 kV, 4400 pF Capacitive Voltage Transformer (1-Phase) EA 12 Included 0.00 0 18 0.00
18 7000009390 180 400kV Equipment 1000004484 85353090 Confirmed 18 Confirmed 420kV, 3150A, 50KA Isolator (3-phase)(Double Break) with two E/S EA 2 Included 0.00 0 18 0.00
19 7000009390 190 400kV Equipment 1000004483 85353090 Confirmed 18 Confirmed 420kV, 3150A, 50KA, Isolator (3-phase)(Double Break) with one E/S EA 18 Included 0.00 0 18 0.00
20 7000009390 200 400kV Equipment 1000004424 85353090 Confirmed 18 Confirmed 420kV, 2000A, 50 KA, Isolator (1 phase)(Double Break) with one E/S EA 7 Included 0.00 0 18 0.00
21 7000009390 210 400kV Equipment 1000004423 85353090 Confirmed 18 Confirmed 420kV, 2000A, 50KA, Isolator (1 phase)(Double Break) without E/S EA 5 Included 0.00 0 18 0.00
22 7000009390 220 400kV Equipment 1000020419 85354010 Confirmed 18 Confirmed 336kV Surge Arrester (1-phase) EA 16 Included 0.00 0 18 0.00
23 7000009390 230 400kV Equipment 1000004401 85462040 Confirmed 18 Confirmed 420 kV, 1 phase Bus Post Insulator (except for Line Traps) EA 60 Included 0.00 0 18 0.00
24 7000009390 240 72.5kV Equipment 1000005069 85359090 Confirmed 18 Confirmed 72.5 kV, 1500A, 31.5 kA, 1-Phase CurrentTransformer with 120% extended currentrating EA 3 Included 0.00 0 18 0.00
25 7000009390 250 72.5kV Equipment 1000005048 85359090 Confirmed 18 Confirmed 72.5 kV Voltage Transformer (1- Phase) EA 3 Included 0.00 0 18 0.00
26 7000009390 260 72.5kV Equipment 1000005039 85352113 Confirmed 18 Confirmed 72.5 kV, 1250A, 31.5 kA, 3-phase CircuitBreaker with support structure EA 1 Included 0.00 0 18 0.00
27 7000009390 270 72.5kV Equipment 1000005037 85353090 Confirmed 18 Confirmed 72.5 kV, 1250A, 31.5 KA, 3-Phase HDBIsolator without E/s EA 2 Included 0.00 0 18 0.00
28 7000009390 2630 72.5kV Equipment 1000005030 85462040 Confirmed 18 Confirmed 72.5kV ,1 phase Bus Post Insulators EA 6 Included 0.00 0 18 0.00
29 7000009390 280 36kV Equipment 1000002064 85353090 Confirmed 18 Confirmed 36 kV, 1250A, 25 KA, 3-Phase DoubleBreak Isolator with one E/s EA 1 Included 0.00 0 18 0.00
30 7000009390 290 36kV Equipment 1000020418 85354010 Confirmed 18 Confirmed 30kV Surge Arrester (1-Phase) EA 3 Included 0.00 0 18 0.00
31 7000009390 300 36kV Equipment 1000002068 85049010 Confirmed 18 Confirmed 36 kV, 1-phase Horn Gap Fuse EA 3 Included 0.00 0 18 0.00
32 7000009390 410 Control& Relay panel- 765kV 1000005074 85371000 Confirmed 18 Confirmed 765 kV Circuit Breaker Relay Panel With Auto Reclose (with Automation) EA 8 Included 0.00 0 18 0.00
33 7000009390 360 Control& Relay panel- 765kV 1000005073 85371000 Confirmed 18 Confirmed 765 kV Circuit Breaker Relay Panel without Auto Reclose (withAutomation) EA 10 Included 0.00 0 18 0.00
34 7000009390 370 Control& Relay panel- 765kV 1000005522 85371000 Confirmed 18 Confirmed 765kV Line Protection Panel (with Automation) EA 4 Included 0.00 0 18 0.00
35 7000009390 380 Control& Relay panel- 765kV 1000005789 85371000 Confirmed 18 Confirmed 765kV Transformer Protection Panel (For both HV & MV side)-(withAutomation) EA 2 Included 0.00 0 18 0.00
36 7000009390 390 Control& Relay panel- 765kV 1000005533 85371000 Confirmed 18 Confirmed 765kV Reactor Protection Panel (with Automation) EA 6 Included 0.00 0 18 0.00
37 7000009390 400 Control& Relay panel- 765kV 1000005071 85371000 Confirmed 18 Confirmed 765kV Bus Bar Protection Panel (Duplicate)-(with Automation) SET 1 Included 0.00 0 18 0.00
38 7000009390 310 Control& Relay panel-420 kV 1000002165 85371000 Confirmed 18 Confirmed 400kV Circuit Breaker Relay Panel with Auto Reclose (with Automation) EA 4 Included 0.00 0 18 0.00
39 7000009390 320 Control& Relay panel-420 kV 1000002163 85371000 Confirmed 18 Confirmed 400kV Circuit Breaker Relay Panel without Auto Reclose (withAutomation) EA 4 Included 0.00 0 18 0.00
40 7000009390 330 Control& Relay panel-420 kV 1000003398 85371000 Confirmed 18 Confirmed 400kV Line Protection Panel (with Automation) EA 2 Included 0.00 0 18 0.00
41 7000009390 340 Control& Relay panel-420 kV 1000003407 85371000 Confirmed 18 Confirmed 400kV Reactor Protection Panel (with Automation) EA 1 Included 0.00 0 18 0.00
42 7000009390 350 Control& Relay panel-420 kV 1000002145 85371000 Confirmed 18 Confirmed 400kV Bus Bar Protection Panel (Duplicate)-(with Automation) SET 1 Included 0.00 0 18 0.00
43 7000009390 420 common equipment 1000021642 85371000 Confirmed 18 Confirmed Time synchronisation equipment EA 1 Included 0.00 0 18 0.00
44 7000009390 430 common equipment 1000025391 82032000 Confirmed 18 Confirmed Relay Test kit EA 1 Included 0.00 0 18 0.00
45 7000009390 440 common equipment 1000025861 85287390 Confirmed 28 Confirmed Visual Monitoring System for Watch & Ward SET 1 Included 0.00 0 28 0.00
46 7000009390 2560 DPC 1000010638 85176210 Confirmed 18 Confirmed Digital Protection Coupler EA 12 Included 0.00 0 18 0.00
47 7000009390 2570 DPC 1000011082 85176210 Confirmed 18 Confirmed EPAX (24/8) with 24 telephones, Cables etc. SET 1 Included 0.00 0 18 0.00
48 7000009390 2580 DPC 1000002134 85176210 Confirmed 18 Confirmed 4wire telephone equipment EA 8 Included 0.00 0 18 0.00
49 7000009390 2590 DPC 1000001104 85176210 Confirmed 18 Confirmed 2wire telephone equipment EA 15 Included 0.00 0 18 0.00
50 7000009390 450 substation automation 1000005534 85371000 Confirmed 18 Confirmed Complete Substation automation system for 765kV Main bay as perTechnical Specification EA 12 Included 0.00 0 18 0.00
51 7000009390 460 substation automation 1000003408 85371000 Confirmed 18 Confirmed Complete Substation automation System for 400kV Main bay as perTechnical Specification EA 6 Included 0.00 0 18 0.00
52 7000009390 470 substation automation 1000005536 85371000 Confirmed 18 Confirmed Complete Substation automation System for 765kV Tie bay as perTechnical Specification EA 2 Included 0.00 0 18 0.00
53 7000009390 500 substation automation 1000003410 85371000 Confirmed 18 Confirmed Complete Substation automation System for 400kV Tie bay as perTechnical Specification EA 2 Included 0.00 0 18 0.00
54 7000009390 480 substation automation 1000005539 85371000 Confirmed 18 Confirmed Complete Substation automation System for 765kV Switchable LineReactor Bay as per Technical Specification EA 4 Included 0.00 0 18 0.00
55 7000009390 490 substation automation 1000018700 85371000 Confirmed 18 Confirmed Complete Substation automation System for controlling and monitoringof Auxilary System including BCUs as per technical specification SET 1 Included 0.00 0 18 0.00
56 7000009390 510 LT Switchgear 1000004313 85371000 Confirmed 18 Confirmed 415V Main Switchboard SET 1 Included 0.00 0 18 0.00
57 7000009390 520 LT Switchgear 1000004303 85371000 Confirmed 18 Confirmed 415V AC Distribution Board (ACDB) as per Technical Specification SET 1 Included 0.00 0 18 0.00
58 7000009390 530 LT Switchgear 1000004312 85371000 Confirmed 18 Confirmed 415V MLDB(along with 2 nos. 300 kVA Lighting transformer) SET 1 Included 0.00 0 18 0.00
59 7000009390 540 LT Switchgear 1000004307 85371000 Confirmed 18 Confirmed 415V Emergency LDB(along with 1 no. 100kVA lighting transformer) SET 1 Included 0.00 0 18 0.00
60 7000009390 550 LT Switchgear 1000004305 85371000 Confirmed 18 Confirmed 415V Airconditioning DB SET 1 Included 0.00 0 18 0.00
61 7000009390 560 LT Switchgear 1000001144 85371000 Confirmed 18 Confirmed 220V DCDB SET 2 Included 0.00 0 18 0.00
62 7000009390 570 LT Switchgear 1000004754 85371000 Confirmed 18 Confirmed 48V DCDB SET 2 Included 0.00 0 18 0.00
63 7000009390 580 battery & charger 1000001151 85072000 Confirmed 28 Confirmed 220V, 1500 Ah Battery SET 2 Included 0.00 0 28 0.00
64 7000009390 590 battery & charger 1000004762 85072000 Confirmed 28 Confirmed 48V, 1500 Ah Battery SET 2 Included 0.00 0 28 0.00
65 7000009390 600 battery & charger 1000001153 85044030 Confirmed 18 Confirmed 220V, 180A/180A Float Cum Boost BatteryCharger EA 2 Included 0.00 0 18 0.00
66 7000009390 610 battery & charger 1000004764 85044030 Confirmed 18 Confirmed 48V, 180A/180A Float Cum Boost BatteryCharger EA 2 Included 0.00 0 18 0.00
67 7000009390 620 DG Set 1000004797 85021310 Confirmed 18 Confirmed 500 kVA Diesel Generator along with control Panel SET 1 Included 0.00 0 18 0.00
68 7000009390 630 air conditioning system 1000013502 84158210 Confirmed 28 Confirmed High wall type split AC unit of 2 TR capacity EA 20 Included 0.00 0 28 0.00
69 7000009390 640 air conditioning system 1000006285 84151090 Confirmed 28 Confirmed Air conditioning system for Switchyard Panel Room of 9m length SET 6 Included 0.00 0 28 0.00
70 7000009390 650 air conditioning system 1000006284 84151090 Confirmed 28 Confirmed Air conditioning system for Switchyard Panel Room of 6m length SET 3 Included 0.00 0 28 0.00
71 7000009390 660 fire protection system 1000012032 84819090 Confirmed 18 Confirmed Pumping arrangement for HVW system & hydrant system, complete withall piping, valves, fittings,etc. inside pump house for FireProtection System of 765/400/220kV (New) Substation SET 1 Included 0.00 0 18 0.00
72 7000009390 670 fire protection system 1000012038 84819090 Confirmed 18 Confirmed Hydrant system, complete U/G piping and accessories etc. outside thePump House for Fire Protection of 765/400/220kV (New) Substation SET 1 Included 0.00 0 18 0.00
73 7000009390 680 fire protection system 1000012027 84241000 Confirmed 18 Confirmed 9litre water type Portable Fire extinguisher EA 4 Included 0.00 0 18 0.00
74 7000009390 690 fire protection system 1000012073 84241000 Confirmed 18 Confirmed 50 litre foam type Trolley/Wheel mounted Fire extinguisher EA 2 Included 0.00 0 18 0.00
75 7000009390 700 fire protection system 1000012022 84241000 Confirmed 18 Confirmed 4.5 kg CO2 type Portable Fire extinguisher EA 20 Included 0.00 0 18 0.00
76 7000009390 710 fire protection system 1000012024 84241000 Confirmed 18 Confirmed Fire Extinguisher Dry Chemical Powder Type(5 Kg) for control room. EA 5 Included 0.00 0 18 0.00
77 7000009390 720 fire protection system 1000012072 84248990 Confirmed 18 Confirmed HVW spray system, Hydrant system and complete U/G & O/G piping andaccessories etc. out side the pump house for 500 MVA,(765/v3)/(400/v3)/(33) kV, 1 -phase Autotransformer SET 7 Included 0.00 0 18 0.00
78 7000009390 740 fire protection system 1000012049 84248990 Confirmed 18 Confirmed HVW spray system, Hydrant system and complete U/G & O/G piping andaccessories etc. out side the pump house for 80 MVAR, 765/√3 kV SinglePhase shunt Reactor SET 7 Included 0.00 0 18 0.00
79 7000009390 750 fire protection system 1000012050 84248990 Confirmed 18 Confirmed HVW spray system, Hydrant system and complete U/G & O/G piping andaccessories etc. out side the pump house for 80 MVAR, 765 kV, singlephase Bus Reactor SET 6 Included 0.00 0 18 0.00
80 7000009390 730 fire protection system 1000012042 84248990 Confirmed 18 Confirmed HVW spray system, Hydrant system and complete U/G & O/G piping andaccessories etc. out side the pump house for 125 MVAR, 420kV, 3 phaseBus Reactor SET 1 Included 0.00 0 18 0.00
81 7000009390 760 fire protection system 1000012041 84248990 Confirmed 18 Confirmed HVW spray system, Hydrant system and complete U/G & O/G piping andaccessories etc. out side the pump house for 110 MVAR, 765/√3 kVsingle phase Shunt Reactor SET 7 Included 0.00 0 18 0.00
82 7000009390 770 fire protection system 1000012015 85311020 Confirmed 18 Confirmed Fire Detection and Alarm System for Control Room Building(765kV) SET 1 Included 0.00 0 18 0.00
83 7000009390 780 fire protection system 1000012019 85311020 Confirmed 18 Confirmed Fire Detection and Alarm System for Switchyard Panel Room of 9 mlength SET 6 Included 0.00 0 18 0.00
84 7000009390 790 fire protection system 1000012018 85311020 Confirmed 18 Confirmed Fire Detection and Alarm System for Switchyard Panel Room of 6 mlength SET 3 Included 0.00 0 18 0.00
85 7000009390 800 Illumination system 1000014547 85371000 Confirmed 18 Confirmed Lighting Panel type ACP-2 as per technical specification EA 8 Included 0.00 0 18 0.00
86 7000009390 810 Illumination system 1000014548 94059900 Confirmed 18 Confirmed Lighting Panel type ACP-3 as per technical specification EA 5 Included 0.00 0 18 0.00
87 7000009390 820 Illumination system 1000020262 85371000 Confirmed 18 Confirmed Sub Lighting panel (outdoor) type SLP (Switchyard and Street Lighting) EA 15 Included 0.00 0 18 0.00
88 7000009390 830 Illumination system 1000004952 94059900 Confirmed 18 Confirmed 63A, 415V : Interlocked switch socket outdoor Receptacle (type RP) asper technical specifications EA 8 Included 0.00 0 18 0.00
89 7000009390 840 Illumination system 1000001050 94059900 Confirmed 18 Confirmed 15A, 240V: Outdoor Receptacle 2 pole, 3-pin modular (type RO) as pertechnical specifications EA 8 Included 0.00 0 18 0.00
90 7000009390 900 Illumination system 1000028444 94059900 Confirmed 18 Confirmed Outdoor Power Receptacle (400A) EA 4 Included 0.00 0 18 0.00
91 7000009390 850 Illumination system 1000024515 76169990 Confirmed 18 Confirmed Cartwheel Mounted Aluminium Ladder as Per Technical Specification EA 1 Included 0.00 0 18 0.00
92 7000009390 860 Illumination system 1000000539 94059900 Confirmed 18 Confirmed Indoor Lighting for 10 cars Parking shed LS 1 Included 0.00 0 18 0.00
93 7000009390 870 Illumination system 1000001894 94059900 Confirmed 18 Confirmed Outdoor Power Receptacle for oilfiltration unit (250A) EA 2 Included 0.00 0 18 0.00
94 7000009390 990 Illumination system 1000009690 94059900 Confirmed 18 Confirmed Control room cum administrative building (765kV) illuminationincluding Conduit LOT 1 Included 0.00 0 18 0.00
95 7000009390 880 Illumination system 1000031063 94059900 Confirmed 18 Confirmed FIRE FIGHTING PUMPHOUSE BUILDING AND DG SET AREA ILLIMUNATION AS PERTECH. SPEC. SET 1 Included 0.00 0 18 0.00
96 7000009390 890 Illumination system 1000013796 94059900 Confirmed 18 Confirmed Illumination System for switchyard panel room of 9 m length LS 6 Included 0.00 0 18 0.00
97 7000009390 980 Illumination system 1000013795 94059900 Confirmed 18 Confirmed Illumination System for switchyard panel room of 6 m length LS 3 Included 0.00 0 18 0.00
98 7000009390 910 Illumination system 1000038325 94059900 Confirmed 18 Confirmed LIGHTING FIXTURE LED LUMINAIRES TYPE FL2 AS PER TECH. SPECIFICATIONS EA 400 Included 0.00 0 18 0.00
99 7000009390 920 Illumination system 1000038385 94059900 Confirmed 18 Confirmed FIRE WALL MOUNTED LED LUMINARIE TYPE FL-2 (250W) EA 52 Included 0.00 0 18 0.00
100 7000009390 930 Illumination system 1000038390 94059900 Confirmed 18 Confirmed PORTABLE FLOOD LIGHT PANEL WITH LED LUMINARIESTYPE FL-2 (250W) EA 2 Included 0.00 0 18 0.00
101 7000009390 940 Illumination system 1000038389 94051090 Confirmed 18 Confirmed LED STREET LIGHT LUMINAIRE TYPE SL-L1 (= 45W)AS PER TECHNICALSPECIFICATION EA 250 Included 0.00 0 18 0.00
102 7000009390 950 Illumination system 1000038388 94051090 Confirmed 18 Confirmed POLE MOUNTED LED POST TOP LUMINAIRE TYPE SL-D1 (= 30W)AS PER TECHNICALSPECIFICATION EA 80 Included 0.00 0 18 0.00
103 7000009390 960 Illumination system 1000038396 94059900 Confirmed 18 Confirmed TYPE D1 POST TOP LANTERN POLE OF 4 METER AS PER TECHNICALSPECIFICATION. EA 80 Included 0.00 0 18 0.00
104 7000009390 970 Illumination system 1000038397 94059900 Confirmed 18 Confirmed TYPE L1 STREET LIGHTING POLE OF 6 METER AS PER TECHNICALSPECIFICATION. EA 250 Included 0.00 0 18 0.00
105 7000009390 1000 Illumination system 1000038386 94059900 Confirmed 18 Confirmed GRID INTERACTIVE SOLAR PV POWER PLANT AS PER TECHNICAL SPECIFICATION LS 1 Included 0.00 0 18 0.00
106 7000009390 1010 Illumination system 1000021809 94059900 Confirmed 18 Confirmed Indoor Lighting for Transit campincluding conduit LS 1 Included 0.00 0 18 0.00
107 7000009390 2610 power & control cable 1000000443 85446020 Confirmed 18 Confirmed 1.1kV grade Power Cables (PVCinsulated)along withlugs,glands,straight joints &accessories,etc. LS 1 Included 0.00 0 18 0.00
108 7000009390 1040 power & control cable 1000000444 85446090 Confirmed 18 Confirmed 1.1kV grade Power Cables (XLPEinsulated) along withlugs,glands,straight joints &accessories,etc. LS 1 Included 0.00 0 18 0.00
109 7000009390 1050 power & control cable 1000000442 85446020 Confirmed 18 Confirmed 1.1kV grade Control Cables (PVCinsulated) along withlugs,glands,straight joints &accessories,etc. LS 1 Included 0.00 0 18 0.00
110 7000009390 1060 power & control cable 1000032045 85446090 Confirmed 18 Confirmed 33KV GRADE HT XLPE CABLE ALONG WITH CLAMPS,LUGS, GLANDS AND STRAIGHTJOINTS. KM 1 Included 0.00 0 18 0.00
111 7000009390 2620 power & control cable 1000004962 85049010 Confirmed 18 Confirmed 66kV HT cable for Tertiary & Netural M 1000 Included 0.00 0 18 0.00
112 7000009390 1070 earthmat 1000032055 72159090 Confirmed 18 Confirmed 40 MM MS ROD FOR MAIN EARTHMAT KM 40 Included 0.00 0 18 0.00
113 7000009390 1080 earthmat 1000011147 85049010 Confirmed 18 Confirmed Material for Earthing of three singlephase units of autotransformer andaccessories like cooler bank, coolercontrol cabinets, common marshallingboxes, local OLTC boxes, neturals,netural CTs, bus post insulators &structures required for neturalformation and DELTA formation and spareunit connection arrangement etc.complete in all respect. LOT 2 Included 0.00 0 18 0.00
114 7000009390 1090 earthmat 1000030673 85049010 Confirmed 18 Confirmed MATERIAL FOR EARTHING OF AUTO-TRANSFORMER TANK, ITS COOLER BANK (IFERECTED), COOLER CONTROL CABINET AND LOCAL OLTC BOX. (FOR ONE NUMBER,(765/√3) / (400/√3) / 33 KV, 1-PHASE, SPARE AUTO-TRANSFORMER UNIT) SET 1 Included 0.00 0 18 0.00
115 7000009390 1100 earthmat 1000011149 85049010 Confirmed 18 Confirmed Material for Earthing of single phaseunits of Reactors and accessories likecooler bank, cooler control cabinets,common marshalling boxes, neturals, oneneutral CT, bus post insulators &structures required for neturalformation and spare unit connectionarrangement etc. for two banks completein all respect LOT 2 Included 0.00 0 18 0.00
116 7000009390 1110 earthmat 1000032992 85049010 Confirmed 18 Confirmed MATERIAL FOR EARTHING OF SEVEN (7) NOS/ SIX (6) NOS.(AS APPLICABLE)SINGLE PHASE UNITS OF REACTORS (FORMING TWO NOS., 3-PH., REACTOR BANKSWITH ONE REACTOR UNIT AS COMMON SPARE(IF APPLICABLE)) AND ACCESSORIES,LIKE THEIR COOLER BANK, COOLER CONTROL CABINETS, COMMON MARSHALLING BOX,NEUTRALS, NEUTRAL CTS, BUS POST INSULATORS AND STRUCTURES REQUIRED FORNEUTRAL FORMATION AND SPARE UNIT CONNECTION ARRANGEMENT (IF APPLICABLE)ETC., COMPLETE IN ALL RESPECT. LS 1 Included 0.00 0 18 0.00
117 7000009390 1120 earthmat 1000030672 85049010 Confirmed 18 Confirmed MATERIAL FOR EARTHING OF REACTOR TANK, ITS COOLER BANK (IF ERECTED)AND M. BOX. (FOR ONE NUMBER, 765KV/√3 KV, 1-PHASE, SPARE REACTOR UNIT) SET 2 Included 0.00 0 18 0.00
118 7000009390 1780 Neutral Formation 1000015788 85049010 Confirmed 18 Confirmed Bus post insulators, spacers, equipmentsupport structures, conductors, Altube, clamp, connectors (including765kV, 400kV, tertiary and neuturalbushing terminal connectors etc) forarrangement of netural formation forTransformer(s), DELTA formation for onebank (each bank comprises of 3 singlephase units of Autotransformers) andmaking connection arrangement toconnect spare unit in place of any unitof the bank without physical shifting LOT 2 Included 0.00 0 18 0.00
119 7000009390 1790 Neutral Formation 1000015929 85049010 Confirmed 18 Confirmed Bus post insulators, spacers, equipmentsupport structures, conductor(s), Altube, clamp, connectors including 765KV and neutral bushings terminalconnectors etc for Neutral formationfor two banks (each bank comprise ofthree single phase units of Reactors)and connection to two neutral groundingreactors and making connectionarrengment to connect spare unit inplace of any unit of all the two bankswithout physical shifting. LOT 2 Included 0.00 0 18 0.00
120 7000009390 1800 Neutral Formation 1000015928 85049010 Confirmed 18 Confirmed Bus post insulators, spacers, equipment support structures includingfoundation bolts,conductor(s), Al tube, clamp, connectors including 765KV and neutral bushings terminal connectors etc for Neutral formationfor two (2) Reactor banks (each bank comprise of three single phaseunits of Reactors) and connection to two (2) neutral grounding Reactorsand making connection arrangement to connect spare unit in place of anyunit of all the two banks without pysical shifting LOT 1 Included 0.00 0 18 0.00
121 7000009390 1130 lattice structure 1000020180 73082011 Confirmed 18 Confirmed Fabrication, galvanising and supply of Std 765 kV Tower CA includingnuts, bolts, all type of washers, packplates, step bolts and gussetplates excluding foundation bolts EA 28 Included 0.00 0 18 0.00
122 7000009390 1140 lattice structure 1000020162 73082011 Confirmed 18 Confirmed Fabrication, galvanising and supply of Std 765 kV Beam BA includingnuts, bolts, all type of washers, packplates, step bolts and gussetplates excluding foundation bolts EA 14 Included 0.00 0 18 0.00
123 7000009390 1150 lattice structure 1000020163 73082011 Confirmed 18 Confirmed Fabrication, galvanising and supply of Std 765 kV Beam BB includingnuts, bolts, all type of washers, packplates, step bolts and gussetplates excluding foundation bolts EA 28 Included 0.00 0 18 0.00
124 7000009390 1160 lattice structure 1000020181 73082011 Confirmed 18 Confirmed Fabrication, galvanising and supply of Std 765 kV Tower CB includingnuts, bolts, all type of washers, packplates, step bolts and gussetplates excluding foundation bolts EA 48 Included 0.00 0 18 0.00
125 7000009390 1170 lattice structure 1000020164 73082011 Confirmed 18 Confirmed Fabrication, galvanising and supply of Std 765 kV Beam BC includingnuts, bolts, all type of washers, packplates, step bolts and gussetplates excluding foundation bolts EA 24 Included 0.00 0 18 0.00
126 7000009390 1180 lattice structure 1000020165 73082011 Confirmed 18 Confirmed Fabrication, galvanising and supply of Std 765 kV Beam BD includingnuts, bolts, all type of washers, packplates, step bolts and gussetplates excluding foundation bolts EA 48 Included 0.00 0 18 0.00
127 7000009390 1190 lattice structure 1000020158 73082011 Confirmed 18 Confirmed Fabrication, galvanising and supply of Std 765 kV Arm GWCB includingnuts, bolts, all type of washers, packplates, step bolts and gussetplates excluding foundation bolts EA 48 Included 0.00 0 18 0.00
128 7000009390 1200 lattice structure 1000020182 73082011 Confirmed 18 Confirmed Fabrication, galvanising and supply of Std 765 kV Tower CC includingnuts, bolts, all type of washers, packplates, step bolts and gussetplates excluding foundation bolts EA 16 Included 0.00 0 18 0.00
129 7000009390 1210 lattice structure 1000020166 73082011 Confirmed 18 Confirmed Fabrication, galvanising and supply of Std 765 kV Beam BE includingnuts, bolts, all type of washers, packplates, step bolts and gussetplates excluding foundation bolts EA 8 Included 0.00 0 18 0.00
130 7000009390 1220 lattice structure 1000020167 73082011 Confirmed 18 Confirmed Fabrication, galvanising and supply of Std 765 kV Beam BF includingnuts, bolts, all type of washers, packplates, step bolts and gussetplates excluding foundation bolts EA 16 Included 0.00 0 18 0.00
131 7000009390 1230 lattice structure 1000020159 73082011 Confirmed 18 Confirmed Fabrication, galvanising and supply of Std 765 kV Arm GWCC includingnuts, bolts, all type of washers, packplates, step bolts and gussetplates excluding foundation bolts EA 16 Included 0.00 0 18 0.00
132 7000009390 1240 lattice structure 1000020125 73082011 Confirmed 18 Confirmed Fabrication, galvanising and supply of Standard 400 kV Tower TCincluding nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts EA 6 Included 0.00 0 18 0.00
133 7000009390 1250 lattice structure 1000020130 73082011 Confirmed 18 Confirmed Fabrication, galvanising and supply of Standard 400 kV Tower THincluding nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts EA 4 Included 0.00 0 18 0.00
134 7000009390 1260 lattice structure 1000020132 73082011 Confirmed 18 Confirmed Fabrication, galvanising and supply of Standard 400 kV Tower TJincluding nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts EA 10 Included 0.00 0 18 0.00
135 7000009390 1270 lattice structure 1000020136 73082011 Confirmed 18 Confirmed Fabrication, galvanising and supply of Standard 400 kV Tower TNincluding nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts EA 6 Included 0.00 0 18 0.00
136 7000009390 1280 lattice structure 1000020118 73082011 Confirmed 18 Confirmed Fabrication, galvanising and supply of Standard 400 kV Gantry G1including nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts EA 8 Included 0.00 0 18 0.00
137 7000009390 1290 lattice structure 1000020119 73082011 Confirmed 18 Confirmed Fabrication, galvanising and supply of Standard 400 kV Gantry G2including nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts EA 14 Included 0.00 0 18 0.00
138 7000009390 1300 lattice structure 1000020175 73082011 Confirmed 18 Confirmed Fabrication, galvanising and supply ofStd 765 kV Support Structure for1-Phase CT including nuts, bolts, alltype of washers, packplates, step boltsand gusset plates excluding foundationbolts EA 42 Included 0.00 0 18 0.00
139 7000009390 1310 lattice structure 1000020176 73082011 Confirmed 18 Confirmed Fabrication, galvanising and supply ofStd 765 kV Support Structure for1-Phase CVT including nuts, bolts, alltype of washers, packplates, step boltsand gusset plates excluding foundationbolts EA 18 Included 0.00 0 18 0.00
140 7000009390 1320 lattice structure 1000020177 73082011 Confirmed 18 Confirmed Fabrication, galvanising and supply ofStd 765 kV Support Structure for3-Phase ISOLATOR including nuts, bolts,all type of washers, packplates, stepbolts and gusset plates excludingfoundation bolts EA 36 Included 0.00 0 18 0.00
141 7000009390 1330 lattice structure 1000030445 73045930 Confirmed 18 Confirmed FABRICATION, GALVANISING AND SUPPLY OFSTD 765 KV SUPPORT STRUCTURE FOR1-PHASE ISOLATOR INCLUDING NUTS,BOLTS, ALL TYPE OF WASHERS, PACKPLATES,STEP BOLTS AND GUSSET PLATES EXCLUDINGFOUNDATION BOLTS EA 72 Included 0.00 0 18 0.00
142 7000009390 1340 lattice structure 1000020178 73082011 Confirmed 18 Confirmed Fabrication, galvanising and supply ofStd 765 kV Support Structure for1-Phase LA including nuts, bolts, alltype of washers, packplates, step boltsand gusset plates excluding foundationbolts EA 39 Included 0.00 0 18 0.00
143 7000009390 1350 lattice structure 1000020174 73082011 Confirmed 18 Confirmed Fabrication, galvanising and supply ofStd 765 kV Support Structure for1-Phase BPI including nuts, bolts, alltype of washers, packplates, step boltsand gusset plates excluding foundationbolts EA 90 Included 0.00 0 18 0.00
144 7000009390 1360 lattice structure 1000020185 73082011 Confirmed 18 Confirmed Fabrication, galvanising and supply of 33kV Std Double Pole Structureincluding nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts EA 1 Included 0.00 0 18 0.00
145 7000009390 1370 PIPE STRUCTURE 1000020192 73045930 Confirmed 18 Confirmed Fabrication, galvanising and supply ofStandard Pipe Structure - 400 kV,1-Phase, CT including nuts, bolts, alltype of washers, packplates, step boltsand gusset plates excluding foundationbolts EA 24 Included 0.00 0 18 0.00
146 7000009390 1380 PIPE STRUCTURE 1000020193 73045930 Confirmed 18 Confirmed Fabrication, galvanising and supply of Standard Pipe Structure - 400kV CVT including nuts, bolts, all type of washers, packplates, stepbolts and gusset plates excluding foundation bolts EA 12 Included 0.00 0 18 0.00
147 7000009390 1390 PIPE STRUCTURE 1000020194 73045930 Confirmed 18 Confirmed Fabrication, galvanising and supply ofStandard Pipe Structure - 400 kV,3-Phase, ISOLATOR including nuts,bolts, all type of washers, packplates,step bolts and gusset plates excludingfoundation bolts EA 20 Included 0.00 0 18 0.00
148 7000009390 1400 PIPE STRUCTURE 1000020195 73045930 Confirmed 18 Confirmed Fabrication, galvanising and supply ofStandard Pipe Structure - 400 kV,1-Phase, SA including nuts, bolts,all type of washers, packplates, stepbolts and gusset plates excludingfoundation bolts EA 16 Included 0.00 0 18 0.00
149 7000009390 1410 PIPE STRUCTURE 1000020196 73045930 Confirmed 18 Confirmed Fabrication, galvanising and supply ofStd Pipe Structure - 400 kV, 1-Phase,BPI, (Excluding Wave Trap), includingnuts, bolts, all type of washers,packplates, step bolts and gussetplates excluding foundation bolts EA 30 Included 0.00 0 18 0.00
150 7000009390 1420 PIPE STRUCTURE 1000029057 73045930 Confirmed 18 Confirmed Fabrication, galvanising and supply of Std 72.5 kV Support Structure1Ph CT including nuts, bolts, all type of washers, packplates, stepboltsand gusset plates excluding foundation bolts EA 3 Included 0.00 0 18 0.00
151 7000009390 1430 PIPE STRUCTURE 1000029058 73045930 Confirmed 18 Confirmed Fabrication, galvanising and supply of Std 72.5 kV Support Structure1Ph CVT including nuts, bolts, all type of washers, packplates, stepboltsand gusset plates excluding foundation bolts EA 3 Included 0.00 0 18 0.00
152 7000009390 1440 PIPE STRUCTURE 1000030444 73045930 Confirmed 18 Confirmed FABRICATION, GALVANISING AND SUPPLY OF STD 72.5 KV SUPPORT STRUCTUREISO 1 - PH INCLUDING NUTS, BOLTS, ALL TYPE OF WASHERS, PACKPLATES,STEP BOLTS AND GUSSET PLATES EXCLUDING FOUNDATION BOLTS EA 6 Included 0.00 0 18 0.00
153 7000009390 1450 PIPE STRUCTURE 1000017570 73045930 Confirmed 18 Confirmed Fabrication, galvanising and supply ofStd Pipe Structure - 400 kV, 1-Phase,High BPI, (Excluding Wave Trap), includingnuts, bolts, all type of washers,packplates, step bolts and gussetplates excluding foundation bolts EA 30 Included 0.00 0 18 0.00
154 7000009390 1460 PIPE STRUCTURE 1000030447 73045930 Confirmed 18 Confirmed FABRICATION, GALVANISING AND SUPPLY OFSTANDARD PIPE STRUCTURE - 400 KVISOLATOR, 1 - PHASE, INCLUDING NUTS,BOLTS, ALL TYPE OF WASHERS, PACKPLATES,STEP BOLTS AND GUSSET PLATES EXCLUDINGFOUNDATION BOLTS EA 12 Included 0.00 0 18 0.00
155 7000009390 2640 PIPE STRUCTURE 1000029056 73045930 Confirmed 18 Confirmed Fabrication, galvanising and supply of Std 72.5 kV Support Structure1Ph BPI including nuts, bolts, all type of washers, packplates, stepboltsand gusset plates excluding foundation bolts EA 6 Included 0.00 0 18 0.00
156 7000009390 1470 ERECTION HARDWARE 1000011358 72169990 Confirmed 18 Confirmed Erection Hardware for 765kV I type layout-Line bay as per technicalspecification SET 4 Included 0.00 0 18 0.00
157 7000009390 1480 ERECTION HARDWARE 1000011363 72169990 Confirmed 18 Confirmed Erection Hardware for 765kV I type layout-Transformer bay as pertechnical specification SET 2 Included 0.00 0 18 0.00
158 7000009390 1490 ERECTION HARDWARE 1000011349 72169990 Confirmed 18 Confirmed Erection Hardware for 765kV I type layout-Bus Reactor bay as pertechnical specification SET 2 Included 0.00 0 18 0.00
159 7000009390 1500 ERECTION HARDWARE 1000011362 72169990 Confirmed 18 Confirmed Erection Hardware for 765kV I type layout-Spare bay of half dia. asper technical specification SET 2 Included 0.00 0 18 0.00
160 7000009390 1510 ERECTION HARDWARE 1000011357 72169990 Confirmed 18 Confirmed Erection Hardware for 765kV I type layout-Line Reactors including NGRbypassing arrangement as per technical specification SET 4 Included 0.00 0 18 0.00
161 7000009390 1520 ERECTION HARDWARE 1000011322 72169990 Confirmed 18 Confirmed Erection Hardware for 400kV I type layout-Line bay as per technicalspecification SET 2 Included 0.00 0 18 0.00
162 7000009390 1530 ERECTION HARDWARE 1000011327 72169990 Confirmed 18 Confirmed Erection Hardware for 400kV I type layout-Transformer bay as pertechnical specification SET 2 Included 0.00 0 18 0.00
163 7000009390 1540 ERECTION HARDWARE 1000011317 72169990 Confirmed 18 Confirmed Erection Hardware for 400kV I type layout-Bus Reactor bay as pertechnical specification SET 1 Included 0.00 0 18 0.00
164 7000009390 1550 ERECTION HARDWARE 1000011326 72169990 Confirmed 18 Confirmed Erection Hardware for 400kV I type layout-Spare bay of half dia as pertechnical specification SET 1 Included 0.00 0 18 0.00
165 7000009390 1560 ERECTION HARDWARE 1000011319 72169990 Confirmed 18 Confirmed Erection Hardware for 400kV I type layout-Bus Work (For two diameters)as per technical specification SET 2 Included 0.00 0 18 0.00
166 7000009390 1570 ERECTION HARDWARE 1000030546 72169990 Confirmed 18 Confirmed Erection Hardware for the 72.5kV and 36kV equipment (scheme as perSLD) SET 1 Included 0.00 0 18 0.00
167 7000009390 1580 ERECTION HARDWARE 1000011350 72169990 Confirmed 18 Confirmed Erection Hardware for 765kV I type layout-Bus Work (For one diameters)as per technical specification SET 6 Included 0.00 0 18 0.00
168 7000009390 1590 145 kV Equipment 1000000945 85352911 Confirmed 18 Confirmed 145kV, 1250A, 31.5KA Circuit Breakers(1-Phase) with support structure EA 4 Included 0.00 0 18 0.00
169 7000009390 1600 765 kV CB spares 1000027625 85352919 Confirmed 18 Confirmed Spare-765KV Circuit Breaker LOT 1 Included 0.00 0 18 0.00
170 7000009390 1610 765 kV Isoator spares 1000028091 85353090 Confirmed 18 Confirmed Spare-765kV VKDB Isolator LOT 1 Included 0.00 0 18 0.00
171 7000009390 1620 765 kV CT spares 1000026479 85389000 Confirmed 18 Confirmed Additional Spares for 765kV CT EA 1 Included 0.00 0 18 0.00
172 7000009390 1630 765 kV CVT spares 1000026480 85359090 Confirmed 18 Confirmed Additional Spares for 765kV CVT EA 1 Included 0.00 0 18 0.00
173 7000009390 1690 624 kV Surge arrester spares 1000020441 85359090 Confirmed 18 Confirmed Surge monitor for 624 kV Surge Arrester (1-Phase) EA 5 Included 0.00 0 18 0.00
174 7000009390 1700 624 kV Surge arrester spares 1000020421 85354010 Confirmed 18 Confirmed 624kV Surge Arrester (1-Phase) EA 1 Included 0.00 0 18 0.00
175 7000009390 1650 420 kV CB spares 1000019918 85359090 Confirmed 18 Confirmed Spares for 420kV Circuit Breaker LS 1 Included 0.00 0 18 0.00
176 7000009390 1660 420 kV Isolator spares 1000019919 85353090 Confirmed 18 Confirmed Spares for 420kV Double break Isolator LS 1 Included 0.00 0 18 0.00
177 7000009390 1670 420 kV CT spares 1000025941 85389000 Confirmed 18 Confirmed Spare-420kV CT 1 SET 1 Included 0.00 0 18 0.00
178 7000009390 1680 420 kV CVT spares 1000025943 85359090 Confirmed 18 Confirmed Spare-420kV CVT 1 SET 1 Included 0.00 0 18 0.00
179 7000009390 1710 336 kV Surge Arrester spares 1000024186 85354010 Confirmed 18 Confirmed SPARES FOR 336KV SURGE ARRESTER LS 1 Included 0.00 0 18 0.00
180 7000009390 1720 220 V Battery Charger spares 1000019914 85049090 Confirmed 18 Confirmed Spares fpr 220V Battery Charger LS 1 Included 0.00 0 18 0.00
181 7000009390 1730 48 V Battery Charger spares 1000019921 85044030 Confirmed 18 Confirmed Spares fpr 48V Battery Charger LS 1 Included 0.00 0 18 0.00
182 7000009390 1740 fire protection system spares 1000019925 84819090 Confirmed 18 Confirmed Spares for Fire Protection System LS 1 Included 0.00 0 18 0.00
183 7000009390 1750 DG Set spares 1000019915 85030010 Confirmed 18 Confirmed Spares for DG set LS 1 Included 0.00 0 18 0.00
184 7000009390 1760 C&P and SCADA spares 1000019912 85371000 Confirmed 18 Confirmed Relay & protection Panels (with automation) LS 1 Included 0.00 0 18 0.00
185 7000009390 1770 C&P and SCADA spares 1000019927 85389000 Confirmed 18 Confirmed Spares-Substation Automation System LS 1 Included 0.00 0 18 0.00
186 7000009390 2060 Non Standard Structure 1000015954 73082011 Confirmed 18 Confirmed Fabrication, galvanising and supply of Lattice Structures (MS Steel),to be designed during detailed engineering, for towers, beams andequipment support structure including pack plates / packwashers andgusset plates excluding fasteners and foundation bolts MT 17 Included 0.00 0 18 0.00
187 7000009390 2070 Non Standard Structure 1000015952 73082011 Confirmed 18 Confirmed Fabrication, galvanising and supply of Equipment Support (Pipe)Structures to be designed during detailed engineering MT 15.2 Included 0.00 0 18 0.00
188 7000009390 2080 Non Standard Structure 1000011713 73082011 Confirmed 18 Confirmed Fabrication, galvanising and supply of fasteners ( nuts, bolts andwashers ) including step bolts for lattice and pipe structures to bedesigned during detailed engineering MT 1 Included 0.00 0 18 0.00
189 7000009390 2090 Non Standard Structure 1000012373 73082011 Confirmed 18 Confirmed Fabrication, galvanising and supply of foundation bolts including nuts,checknut and washers for lattice and pipe structures to be designedduring detailed engineering MT 2.7 Included 0.00 0 18 0.00
190 7000009390 2110 Foundation Bolts 1000012366 73082011 Confirmed 18 Confirmed Fabrication, galvanising and supply of 28mm dia foundation boltsincluding nuts, checknuts, washers and packplates. EA 1060 Included 0.00 0 18 0.00
191 7000009390 2120 Foundation Bolts 1000012367 73082011 Confirmed 18 Confirmed Fabrication, galvanising and supply of 32mm dia foundation boltsincluding nuts, checknuts, washers and packplates EA 6348 Included 0.00 0 18 0.00
192 7000009390 2130 Foundation Bolts 1000012369 73082011 Confirmed 18 Confirmed Fabrication, galvanising and supply of 56mm dia foundation boltsincluding nuts, checknuts, washers and packplates EA 768 Included 0.00 0 18 0.00
193 7000009390 2140 Foundation Bolts 1000012371 73082011 Confirmed 18 Confirmed Fabrication, galvanising and supply of 80mm dia foundation boltsincluding nuts, checknuts, washers and packplates EA 1024 Included 0.00 0 18 0.00
194 7000009390 2150 765kV pmu and associated equip. 1000017518 85364900 Confirmed 18 Confirmed PMU with GPS Clock (clock can be either internal or external) EA 4 Included 0.00 0 18 0.00
195 7000009390 2160 765kV pmu and associated equip. 1000022512 90311000 Confirmed 18 Confirmed WAMS Hardware - Time System (GPS receiver) EA 4 Included 0.00 0 18 0.00
196 7000009390 2170 765kV pmu and associated equip. 1000022510 85176290 Confirmed 18 Confirmed WAMS Hardware - Substation Grade Layer-3 LAN Switches with minimum 4 x10/100 Mbps Ethernet ports and 2 x 1 Gbps Ethernet ports EA 5 Included 0.00 0 18 0.00
197 7000009390 2180 765kV pmu and associated equip. 1000022487 85447090 Confirmed 18 Confirmed WAMS Miscellaneous - Armored Fibre Optic Cable and associatedtermination (e.g. L2 Switch) for connecting PMU panels located indifferent control room of a station EA 1 Included 0.00 0 18 0.00
198 7000009390 2200 400 kV PMU and associated equip. 1000017518 85364900 Confirmed 18 Confirmed PMU with GPS Clock (clock can be either internal or external) EA 2 Included 0.00 0 18 0.00
199 7000009390 2210 400 kV PMU and associated equip. 1000022512 90311000 Confirmed 18 Confirmed WAMS Hardware - Time System (GPS receiver) EA 2 Included 0.00 0 18 0.00
200 7000009390 2220 400 kV PMU and associated equip. 1000022510 85176290 Confirmed 18 Confirmed WAMS Hardware - Substation Grade Layer-3 LAN Switches with minimum 4 x10/100 Mbps Ethernet ports and 2 x 1 Gbps Ethernet ports EA 3 Included 0.00 0 18 0.00
201 7000009390 2230 400 kV PMU and associated equip. 1000022487 85447090 Confirmed 18 Confirmed WAMS Miscellaneous - Armored Fibre Optic Cable and associatedtermination (e.g. L2 Switch) for connecting PMU panels located indifferent control room of a station EA 1 Included 0.00 0 18 0.00
202 7000009390 2250 Tele equipment at Bhadla-2 incl repeater 1000031367 85176260 Confirmed 18 Confirmed SDH EQUIPMENT (STM-16 MADM UPTO 5 MSP PROTECTED DIRECTIONS)-BASEEQUIPMENT (COMMON CARDS, CROSS CONNECT/CONTROL CARDS, OPTICAL BASECARDS, POWER SUPPLY CARDS, POWER CABLING, OTHER HARDWARE ANDACCESSORIES INCLUDING SUB RACKS, PATCH CORD, DDF ETC FULLY EQUIPEDEXCLUDING OPTICAL INTERFACE & TRIBUTARY CARDS EA 2 Included 0.00 0 18 0.00
203 7000009390 2260 Tele equipment at Bhadla-2 incl repeater 1000031881 85176260 Confirmed 18 Confirmed SDH EQUIPMENT (STM-16 MADM UPTO 3 MSP PROTECTED DIRECTIONS)-BASEEQUIPMENT (COMMON CARDS, CROSS CONNECT/CONTROL CARDS, OPTICAL BASECARDS, POWER SUPPLY CARDS, POWER CABLING, OTHER HARDWARE ANDACCESSORIES INCLUDING SUB RACKS, PATCH CORD, DDF ETC FULLY EQUIPEDEXCLUDING OPTICAL INTERFACE & TRIBUTARY CARDS EA 1 Included 0.00 0 18 0.00
204 7000009390 2270 Tele equipment at Bhadla-2 incl repeater 1000018706 85176990 Confirmed 18 Confirmed S16.1 SFP EA 4 Included 0.00 0 18 0.00
205 7000009390 2410 Tele equipment at Bhadla-2 incl repeater 1000014272 85176290 Confirmed 18 Confirmed L16.1 SFP EA 2 Included 0.00 0 18 0.00
206 7000009390 2280 Tele equipment at Bhadla-2 incl repeater 1000014273 85176990 Confirmed 18 Confirmed L16.2 SFP EA 2 Included 0.00 0 18 0.00
207 7000009390 2290 Tele equipment at Bhadla-2 incl repeater 1000019315 85176290 Confirmed 18 Confirmed Optical Line Interface card (to support minimum 150 kms) EA 2 Included 0.00 0 18 0.00
208 7000009390 2300 Tele equipment at Bhadla-2 incl repeater 1000019317 85176290 Confirmed 18 Confirmed Optical Line Interface card To support minimum 175 km EA 2 Included 0.00 0 18 0.00
209 7000009390 2310 Tele equipment at Bhadla-2 incl repeater 1000019316 85176290 Confirmed 18 Confirmed Optical Line Interface card To support minimum 200 km EA 4 Included 0.00 0 18 0.00
210 7000009390 2320 Tele equipment at Bhadla-2 incl repeater 1000031405 85176290 Confirmed 18 Confirmed OPTICAL INTERFACE CARD (TO SUPPORT MINIMUM 225 KMS) FOR STM-16 EA 4 Included 0.00 0 18 0.00
211 7000009390 2330 Tele equipment at Bhadla-2 incl repeater 1000031374 85176290 Confirmed 18 Confirmed TRIBUTARY INTERFACE- E1 INTERFACE (MINIMUM 16 NOS.) SET 4 Included 0.00 0 18 0.00
212 7000009390 2340 Tele equipment at Bhadla-2 incl repeater 1000034950 85176990 Confirmed 18 Confirmed ETHERNET INTERFACE 10/100 BASE T WITH LAYER-2 SWITCHING (MIN 8INTERFACES PER CARD) EA 4 Included 0.00 0 18 0.00
213 7000009390 2350 Tele equipment at Bhadla-2 incl repeater 1000031381 85176290 Confirmed 18 Confirmed TRIBUTARY INTERFACE-GIGABIT ETHERNET INTERFACES 10/100 MBPS WITH LAYER-2 SWITCHING (MINIMUM 2 NOS.) SET 2 Included 0.00 0 18 0.00
214 7000009390 2360 Tele equipment at Bhadla-2 incl repeater 1000026228 85176290 Confirmed 18 Confirmed Equipment Cabinets For SDH EA 3 Included 0.00 0 18 0.00
215 7000009390 2370 Tele equipment at Bhadla-2 incl repeater 1000028495 84715000 Confirmed 18 Confirmed NMS- CRAFT TERMINAL-HARDWARE EA 2 Included 0.00 0 18 0.00
216 7000009390 2380 Tele equipment at Bhadla-2 incl repeater 1000028265 85238020 Confirmed 18 Confirmed Software for Craft Terminal EA 2 Included 0.00 0 18 0.00
217 7000009390 2390 Tele equipment at Bhadla-2 incl repeater 1000034998 85171890 Confirmed 18 Confirmed VOIP TELEPHONE INSTRUMENT WITH ONE COMMON SWITCH (MIN. 8 PORT) EA 8 Included 0.00 0 18 0.00
218 7000009390 2400 Tele equipment at Bhadla-2 incl repeater 1000031403 85437099 Confirmed 18 Confirmed REPEATER SHELTER SYSTEM INCLUDING ALL SHELTER ITEMS SUCH ASAIR-CONDITIONER, DG SETS, STATIC VOLTAGE STABLISER, DCPS & BATTERY ETC AS PER TECHNICAL SPECIFICATION OF PUF INSULATED PRE-COATED STEELSHELTER (INNER DIMENSION : 4340 X 2540 X 3000 MM & OUTER DIMENSION4500 X 2700 X 3160 MM) SET 1 Included 0.00 0 18 0.00
219 7000009390 2420 spares of tele eqpt at Bhadla-2 incl rep 1000031369 85176260 Confirmed 18 Confirmed SDH EQUIPMENT (STM-16 MADM UPTO 5 MSP PROTECTED DIRECTIONS)-COMMONCARDS, CROSS-CONNECT/CONTROL CARDS, OPTICAL BASE CARD, POWER SUPPLYCARDS, POWER CABLING, OTHER HARDWARE & ACCESSORIES (EACH). SET 1 Included 0.00 0 18 0.00
220 7000009390 2430 spares of tele eqpt at Bhadla-2 incl rep 1000018706 85176990 Confirmed 18 Confirmed S16.1 SFP EA 1 Included 0.00 0 18 0.00
221 7000009390 2540 spares of tele eqpt at Bhadla-2 incl rep 1000014272 85176290 Confirmed 18 Confirmed L16.1 SFP EA 1 Included 0.00 0 18 0.00
222 7000009390 2440 spares of tele eqpt at Bhadla-2 incl rep 1000014273 85176990 Confirmed 18 Confirmed L16.2 SFP EA 1 Included 0.00 0 18 0.00
223 7000009390 2450 spares of tele eqpt at Bhadla-2 incl rep 1000019315 85176290 Confirmed 18 Confirmed Optical Line Interface card (to support minimum 150 kms) EA 1 Included 0.00 0 18 0.00
224 7000009390 2460 spares of tele eqpt at Bhadla-2 incl rep 1000019317 85176290 Confirmed 18 Confirmed Optical Line Interface card To support minimum 175 km EA 1 Included 0.00 0 18 0.00
225 7000009390 2470 spares of tele eqpt at Bhadla-2 incl rep 1000019316 85176290 Confirmed 18 Confirmed Optical Line Interface card To support minimum 200 km EA 1 Included 0.00 0 18 0.00
226 7000009390 2530 spares of tele eqpt at Bhadla-2 incl rep 1000031405 85176290 Confirmed 18 Confirmed OPTICAL INTERFACE CARD (TO SUPPORT MINIMUM 225 KMS) FOR STM-16 EA 1 Included 0.00 0 18 0.00
227 7000009390 2480 spares of tele eqpt at Bhadla-2 incl rep 1000031374 85176290 Confirmed 18 Confirmed TRIBUTARY INTERFACE- E1 INTERFACE (MINIMUM 16 NOS.) SET 1 Included 0.00 0 18 0.00
228 7000009390 2490 spares of tele eqpt at Bhadla-2 incl rep 1000034950 85176990 Confirmed 18 Confirmed ETHERNET INTERFACE 10/100 BASE T WITH LAYER-2 SWITCHING (MIN 8INTERFACES PER CARD) EA 1 Included 0.00 0 18 0.00
229 7000009390 2500 spares of tele eqpt at Bhadla-2 incl rep 1000031381 85176290 Confirmed 18 Confirmed TRIBUTARY INTERFACE-GIGABIT ETHERNET INTERFACES 10/100 MBPS WITH LAYER-2 SWITCHING (MINIMUM 2 NOS.) SET 1 Included 0.00 0 18 0.00
230 7000009390 2510 spares of tele eqpt at Bhadla-2 incl rep 1000034998 85171890 Confirmed 18 Confirmed VOIP TELEPHONE INSTRUMENT WITH ONE COMMON SWITCH (MIN. 8 PORT) EA 1 Included 0.00 0 18 0.00
231 7000009390 2520 spares of tele eqpt at Bhadla-2 incl rep 1000031398 85171890 Confirmed 18 Confirmed PRE CONNECTORIZED OPTICAL FIBER PATCH CORDS(10 MTRS) – PACK OF SIXPATCH CORDS SET 1 Included 0.00 0 18 0.00
Total Ex-works Price 0.00
Total Type Test charges as per Schedule-7 0.00
Total Ex-works Price including Type Test charges 0.00
Total GST Tax as confirmed by Bidder 0.00
Note : Specify amount of GST on the transaction between the Contractor and the Employer.
* In case the bidder leaves the cell for confirmation of the HSN code and/or GST rate “blank”, the HSN code and corresponding GST rate indicated by the Employer shall be deemed to be the one confirmed by the Bidder.
Place : Printed Name :
CC-CS/912-NR1/SS-3933/3/G10 (SS29) Schedule - 1 Direct Total 0 0 `
BO Total #REF! 0
AIS Substation Package-SS29 Establishment of 765/400kV Bhadla-II PS (Jodhpur) new S/S under Transmission Scheme for Solar Energy Zones in Rajasthan
(SCHEDULE OF RATES AND PRICES : EX-WORKS PRICES)
Bidder’s Name and Address (Lead Partner) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Gurgaon (Haryana) - 122001
Plant and Equipment (including Mandatory Spares Parts) to be supplied, including Type Test Charges for Tests to be conducted. Direct
All Prices are in Indian Rupees. Bought-Out
SI. No. Item Description Unit Qty. Unit Ex-works price Total Ex-works price Mode of Transaction (Direct / Bought-out)
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
Total Ex-Works Price Direct 0.00 Direct
Total Ex-Works Price Bought Out 0.00
Total Ex-Works Price 0.00
Total Type Test charges as per Schedule-7 #REF! #REF! #REF!
Total Ex-works Price including Type Test charges #REF! #REF! #REF!
Discount Sch-1 #REF! MPD Sch-1 #REF!
Dis Alert #REF!
Note : Specify amount of Excise Duty, Sales Tax/'VAT and other taxes payable on the transaction between the Contractor and the Employer and octroi/entry tax as applicable for destination site/state on all items of supply including bought-out finished items (to be identified in the Contract), which shall be dispatched directly from the sub-vendor’s works to the Employer’s site (sale-in-transit), separately in Schedule-5. Excise Duty, Sales tax and other levies for all the bought-out items are to be included in the EXW Price (Col. No. 5) only and not to be indicated in Schedule-5.
Place : Printed Name :
CC-CS/912-NR1/SS-3933/3/G10 (SS29) Schedule - 2
AIS Substation Package-SS29 Establishment of 765/400kV Bhadla-II PS (Jodhpur) new S/S under Transmission Scheme for Solar Energy Zones in Rajasthan
(SCHEDULE OF RATES AND PRICES)
Bidder’s Name and Address (Lead Partner) : To:
Contracts Services, 3rd Floor
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Gurgaon (Haryana) - 122001
LOCAL TRANSPORTATION, IN-TRANSIT INSURANCE, LOADING AND UNLOADING
All Prices are in Indian Rupees.
SI. No. PR No PR Line Item No Activity Description Material Code Description Unit Quantity Unit Freight, In-transit Insurance, loading & unloading Charges Total Freight, In-transit Insurance, loading & unloading Charges
I AIS Bhadla-2 (Jodhpur) New SS
1 7000009390 10 LT Transformer 1000006173 800kVA, 33/0.433kV, 3ph LT Transformer EA 2 Included
2 7000009390 20 800kV Equipment 1000031204 765KV, 3150A, 40KA CIRCUIT BREAKER WITH CLOSING RESISTOR WITHCONTROLLED SWITCHING DEVICE (WITH SUPPORT STRUCTURES) EA 2 Included
3 7000009390 30 800kV Equipment 1000005818 765kV, 3150A, 40KA Circuit Breaker(3-Phase) with closing resistor (withsupport structure) EA 6 Included
4 7000009390 40 800kV Equipment 1000031203 765KV, 3150A, 40KA CIRCUIT BREAKER WITHOUT CLOSING RESISTOR WITHCONTROLLED SWITCHING DEVICE (WITH SUPPORT STRUCTURES) EA 10 Included
5 7000009390 50 800kV Equipment 1000005855 765kV, 3150A, 40KA Circuit Breakerwithout closing resistor suitable for1-ph Reactor switching EA 2 Included
6 7000009390 60 800kV Equipment 1000005811 765 kV, 3000A, 40KA, 1-Phase CurrentTransformer with 120% extended currentrating EA 42 Included
7 7000009390 70 800kV Equipment 1000005840 765 kV,8800 pF Capacitive Voltage Transformer (1-Phase) EA 18 Included
8 7000009390 80 800kV Equipment 1000005850 765kV, 3150A, 40 KA, VerticalKnee/Double Break Isolator (3-Phase)with one E/S EA 22 Included
9 7000009390 90 800kV Equipment 1000005851 765kV, 3150A, 40 KA, VerticalKnee/Double Break Isolator (3-Phase)with two E/S EA 14 Included
10 7000009390 100 800kV Equipment 1000005841 765kV, 2000A, 40 KA, VerticalKnee/Double Break Isolator (1-Phase)with one E/S EA 27 Included
11 7000009390 110 800kV Equipment 1000005792 765kV, 2000A, 40 KA, VerticalKnee/Double Break Isolator (1-Phase)without E/S EA 45 Included
12 7000009390 120 800kV Equipment 1000005791 765 kV, 1 phase Bus Post Insulator (except for Line Traps) EA 90 Included
13 7000009390 130 800kV Equipment 1000020421 624kV Surge Arrester (1-Phase) EA 39 Included
14 7000009390 140 400kV Equipment 1000009711 Controlled switching device for 420 kV, 3 phase circuit breaker SET 6 Included
15 7000009390 150 400kV Equipment 1000004489 420kV, 3150A, 50kA Circuit Breaker(3-Phase) without closing resistor EA 8 Included
16 7000009390 160 400kV Equipment 1000004461 420 kV, 3000A, 50KA, 1-Phase CurrentTransformer with 120% extended currentrating EA 24 Included
17 7000009390 170 400kV Equipment 1000004535 420 kV, 4400 pF Capacitive Voltage Transformer (1-Phase) EA 12 Included
18 7000009390 180 400kV Equipment 1000004484 420kV, 3150A, 50KA Isolator (3-phase)(Double Break) with two E/S EA 2 Included
19 7000009390 190 400kV Equipment 1000004483 420kV, 3150A, 50KA, Isolator (3-phase)(Double Break) with one E/S EA 18 Included
20 7000009390 200 400kV Equipment 1000004424 420kV, 2000A, 50 KA, Isolator (1 phase)(Double Break) with one E/S EA 7 Included
21 7000009390 210 400kV Equipment 1000004423 420kV, 2000A, 50KA, Isolator (1 phase)(Double Break) without E/S EA 5 Included
22 7000009390 220 400kV Equipment 1000020419 336kV Surge Arrester (1-phase) EA 16 Included
23 7000009390 230 400kV Equipment 1000004401 420 kV, 1 phase Bus Post Insulator (except for Line Traps) EA 60 Included
24 7000009390 240 72.5kV Equipment 1000005069 72.5 kV, 1500A, 31.5 kA, 1-Phase CurrentTransformer with 120% extended currentrating EA 3 Included
25 7000009390 250 72.5kV Equipment 1000005048 72.5 kV Voltage Transformer (1- Phase) EA 3 Included
26 7000009390 260 72.5kV Equipment 1000005039 72.5 kV, 1250A, 31.5 kA, 3-phase CircuitBreaker with support structure EA 1 Included
27 7000009390 270 72.5kV Equipment 1000005037 72.5 kV, 1250A, 31.5 KA, 3-Phase HDBIsolator without E/s EA 2 Included
28 7000009390 2630 72.5kV Equipment 1000005030 72.5kV ,1 phase Bus Post Insulators EA 6 Included
29 7000009390 280 36kV Equipment 1000002064 36 kV, 1250A, 25 KA, 3-Phase DoubleBreak Isolator with one E/s EA 1 Included
30 7000009390 290 36kV Equipment 1000020418 30kV Surge Arrester (1-Phase) EA 3 Included
31 7000009390 300 36kV Equipment 1000002068 36 kV, 1-phase Horn Gap Fuse EA 3 Included
32 7000009390 410 Control& Relay panel- 765kV 1000005074 765 kV Circuit Breaker Relay Panel With Auto Reclose (with Automation) EA 8 Included
33 7000009390 360 Control& Relay panel- 765kV 1000005073 765 kV Circuit Breaker Relay Panel without Auto Reclose (withAutomation) EA 10 Included
34 7000009390 370 Control& Relay panel- 765kV 1000005522 765kV Line Protection Panel (with Automation) EA 4 Included
35 7000009390 380 Control& Relay panel- 765kV 1000005789 765kV Transformer Protection Panel (For both HV & MV side)-(withAutomation) EA 2 Included
36 7000009390 390 Control& Relay panel- 765kV 1000005533 765kV Reactor Protection Panel (with Automation) EA 6 Included
37 7000009390 400 Control& Relay panel- 765kV 1000005071 765kV Bus Bar Protection Panel (Duplicate)-(with Automation) SET 1 Included
38 7000009390 310 Control& Relay panel-420 kV 1000002165 400kV Circuit Breaker Relay Panel with Auto Reclose (with Automation) EA 4 Included
39 7000009390 320 Control& Relay panel-420 kV 1000002163 400kV Circuit Breaker Relay Panel without Auto Reclose (withAutomation) EA 4 Included
40 7000009390 330 Control& Relay panel-420 kV 1000003398 400kV Line Protection Panel (with Automation) EA 2 Included
41 7000009390 340 Control& Relay panel-420 kV 1000003407 400kV Reactor Protection Panel (with Automation) EA 1 Included
42 7000009390 350 Control& Relay panel-420 kV 1000002145 400kV Bus Bar Protection Panel (Duplicate)-(with Automation) SET 1 Included
43 7000009390 420 common equipment 1000021642 Time synchronisation equipment EA 1 Included
44 7000009390 430 common equipment 1000025391 Relay Test kit EA 1 Included
45 7000009390 440 common equipment 1000025861 Visual Monitoring System for Watch & Ward SET 1 Included
46 7000009390 2560 DPC 1000010638 Digital Protection Coupler EA 12 Included
47 7000009390 2570 DPC 1000011082 EPAX (24/8) with 24 telephones, Cables etc. SET 1 Included
48 7000009390 2580 DPC 1000002134 4wire telephone equipment EA 8 Included
49 7000009390 2590 DPC 1000001104 2wire telephone equipment EA 15 Included
50 7000009390 450 substation automation 1000005534 Complete Substation automation system for 765kV Main bay as perTechnical Specification EA 12 Included
51 7000009390 460 substation automation 1000003408 Complete Substation automation System for 400kV Main bay as perTechnical Specification EA 6 Included
52 7000009390 470 substation automation 1000005536 Complete Substation automation System for 765kV Tie bay as perTechnical Specification EA 2 Included
53 7000009390 500 substation automation 1000003410 Complete Substation automation System for 400kV Tie bay as perTechnical Specification EA 2 Included
54 7000009390 480 substation automation 1000005539 Complete Substation automation System for 765kV Switchable LineReactor Bay as per Technical Specification EA 4 Included
55 7000009390 490 substation automation 1000018700 Complete Substation automation System for controlling and monitoringof Auxilary System including BCUs as per technical specification SET 1 Included
56 7000009390 510 LT Switchgear 1000004313 415V Main Switchboard SET 1 Included
57 7000009390 520 LT Switchgear 1000004303 415V AC Distribution Board (ACDB) as per Technical Specification SET 1 Included
58 7000009390 530 LT Switchgear 1000004312 415V MLDB(along with 2 nos. 300 kVA Lighting transformer) SET 1 Included
59 7000009390 540 LT Switchgear 1000004307 415V Emergency LDB(along with 1 no. 100kVA lighting transformer) SET 1 Included
60 7000009390 550 LT Switchgear 1000004305 415V Airconditioning DB SET 1 Included
61 7000009390 560 LT Switchgear 1000001144 220V DCDB SET 2 Included
62 7000009390 570 LT Switchgear 1000004754 48V DCDB SET 2 Included
63 7000009390 580 battery & charger 1000001151 220V, 1500 Ah Battery SET 2 Included
64 7000009390 590 battery & charger 1000004762 48V, 1500 Ah Battery SET 2 Included
65 7000009390 600 battery & charger 1000001153 220V, 180A/180A Float Cum Boost BatteryCharger EA 2 Included
66 7000009390 610 battery & charger 1000004764 48V, 180A/180A Float Cum Boost BatteryCharger EA 2 Included
67 7000009390 620 DG Set 1000004797 500 kVA Diesel Generator along with control Panel SET 1 Included
68 7000009390 630 air conditioning system 1000013502 High wall type split AC unit of 2 TR capacity EA 20 Included
69 7000009390 640 air conditioning system 1000006285 Air conditioning system for Switchyard Panel Room of 9m length SET 6 Included
70 7000009390 650 air conditioning system 1000006284 Air conditioning system for Switchyard Panel Room of 6m length SET 3 Included
71 7000009390 660 fire protection system 1000012032 Pumping arrangement for HVW system & hydrant system, complete withall piping, valves, fittings,etc. inside pump house for FireProtection System of 765/400/220kV (New) Substation SET 1 Included
72 7000009390 670 fire protection system 1000012038 Hydrant system, complete U/G piping and accessories etc. outside thePump House for Fire Protection of 765/400/220kV (New) Substation SET 1 Included
73 7000009390 680 fire protection system 1000012027 9litre water type Portable Fire extinguisher EA 4 Included
74 7000009390 690 fire protection system 1000012073 50 litre foam type Trolley/Wheel mounted Fire extinguisher EA 2 Included
75 7000009390 700 fire protection system 1000012022 4.5 kg CO2 type Portable Fire extinguisher EA 20 Included
76 7000009390 710 fire protection system 1000012024 Fire Extinguisher Dry Chemical Powder Type(5 Kg) for control room. EA 5 Included
77 7000009390 720 fire protection system 1000012072 HVW spray system, Hydrant system and complete U/G & O/G piping andaccessories etc. out side the pump house for 500 MVA,(765/v3)/(400/v3)/(33) kV, 1 -phase Autotransformer SET 7 Included
78 7000009390 740 fire protection system 1000012049 HVW spray system, Hydrant system and complete U/G & O/G piping andaccessories etc. out side the pump house for 80 MVAR, 765/√3 kV SinglePhase shunt Reactor SET 7 Included
79 7000009390 750 fire protection system 1000012050 HVW spray system, Hydrant system and complete U/G & O/G piping andaccessories etc. out side the pump house for 80 MVAR, 765 kV, singlephase Bus Reactor SET 6 Included
80 7000009390 730 fire protection system 1000012042 HVW spray system, Hydrant system and complete U/G & O/G piping andaccessories etc. out side the pump house for 125 MVAR, 420kV, 3 phaseBus Reactor SET 1 Included
81 7000009390 760 fire protection system 1000012041 HVW spray system, Hydrant system and complete U/G & O/G piping andaccessories etc. out side the pump house for 110 MVAR, 765/√3 kVsingle phase Shunt Reactor SET 7 Included
82 7000009390 770 fire protection system 1000012015 Fire Detection and Alarm System for Control Room Building(765kV) SET 1 Included
83 7000009390 780 fire protection system 1000012019 Fire Detection and Alarm System for Switchyard Panel Room of 9 mlength SET 6 Included
84 7000009390 790 fire protection system 1000012018 Fire Detection and Alarm System for Switchyard Panel Room of 6 mlength SET 3 Included
85 7000009390 800 Illumination system 1000014547 Lighting Panel type ACP-2 as per technical specification EA 8 Included
86 7000009390 810 Illumination system 1000014548 Lighting Panel type ACP-3 as per technical specification EA 5 Included
87 7000009390 820 Illumination system 1000020262 Sub Lighting panel (outdoor) type SLP (Switchyard and Street Lighting) EA 15 Included
88 7000009390 830 Illumination system 1000004952 63A, 415V : Interlocked switch socket outdoor Receptacle (type RP) asper technical specifications EA 8 Included
89 7000009390 840 Illumination system 1000001050 15A, 240V: Outdoor Receptacle 2 pole, 3-pin modular (type RO) as pertechnical specifications EA 8 Included
90 7000009390 900 Illumination system 1000028444 Outdoor Power Receptacle (400A) EA 4 Included
91 7000009390 850 Illumination system 1000024515 Cartwheel Mounted Aluminium Ladder as Per Technical Specification EA 1 Included
92 7000009390 860 Illumination system 1000000539 Indoor Lighting for 10 cars Parking shed LS 1 Included
93 7000009390 870 Illumination system 1000001894 Outdoor Power Receptacle for oilfiltration unit (250A) EA 2 Included
94 7000009390 990 Illumination system 1000009690 Control room cum administrative building (765kV) illuminationincluding Conduit LOT 1 Included
95 7000009390 880 Illumination system 1000031063 FIRE FIGHTING PUMPHOUSE BUILDING AND DG SET AREA ILLIMUNATION AS PERTECH. SPEC. SET 1 Included
96 7000009390 890 Illumination system 1000013796 Illumination System for switchyard panel room of 9 m length LS 6 Included
97 7000009390 980 Illumination system 1000013795 Illumination System for switchyard panel room of 6 m length LS 3 Included
98 7000009390 910 Illumination system 1000038325 LIGHTING FIXTURE LED LUMINAIRES TYPE FL2 AS PER TECH. SPECIFICATIONS EA 400 Included
99 7000009390 920 Illumination system 1000038385 FIRE WALL MOUNTED LED LUMINARIE TYPE FL-2 (250W) EA 52 Included
100 7000009390 930 Illumination system 1000038390 PORTABLE FLOOD LIGHT PANEL WITH LED LUMINARIESTYPE FL-2 (250W) EA 2 Included
101 7000009390 940 Illumination system 1000038389 LED STREET LIGHT LUMINAIRE TYPE SL-L1 (= 45W)AS PER TECHNICALSPECIFICATION EA 250 Included
102 7000009390 950 Illumination system 1000038388 POLE MOUNTED LED POST TOP LUMINAIRE TYPE SL-D1 (= 30W)AS PER TECHNICALSPECIFICATION EA 80 Included
103 7000009390 960 Illumination system 1000038396 TYPE D1 POST TOP LANTERN POLE OF 4 METER AS PER TECHNICALSPECIFICATION. EA 80 Included
104 7000009390 970 Illumination system 1000038397 TYPE L1 STREET LIGHTING POLE OF 6 METER AS PER TECHNICALSPECIFICATION. EA 250 Included
105 7000009390 1000 Illumination system 1000038386 GRID INTERACTIVE SOLAR PV POWER PLANT AS PER TECHNICAL SPECIFICATION LS 1 Included
106 7000009390 1010 Illumination system 1000021809 Indoor Lighting for Transit campincluding conduit LS 1 Included
107 7000009390 2610 power & control cable 1000000443 1.1kV grade Power Cables (PVCinsulated)along withlugs,glands,straight joints &accessories,etc. LS 1 Included
108 7000009390 1040 power & control cable 1000000444 1.1kV grade Power Cables (XLPEinsulated) along withlugs,glands,straight joints &accessories,etc. LS 1 Included
109 7000009390 1050 power & control cable 1000000442 1.1kV grade Control Cables (PVCinsulated) along withlugs,glands,straight joints &accessories,etc. LS 1 Included
110 7000009390 1060 power & control cable 1000032045 33KV GRADE HT XLPE CABLE ALONG WITH CLAMPS,LUGS, GLANDS AND STRAIGHTJOINTS. KM 1 Included
111 7000009390 2620 power & control cable 1000004962 66kV HT cable for Tertiary & Netural M 1000 Included
112 7000009390 1070 earthmat 1000032055 40 MM MS ROD FOR MAIN EARTHMAT KM 40 Included
113 7000009390 1080 earthmat 1000011147 Material for Earthing of three singlephase units of autotransformer andaccessories like cooler bank, coolercontrol cabinets, common marshallingboxes, local OLTC boxes, neturals,netural CTs, bus post insulators &structures required for neturalformation and DELTA formation and spareunit connection arrangement etc.complete in all respect. LOT 2 Included
114 7000009390 1090 earthmat 1000030673 MATERIAL FOR EARTHING OF AUTO-TRANSFORMER TANK, ITS COOLER BANK (IFERECTED), COOLER CONTROL CABINET AND LOCAL OLTC BOX. (FOR ONE NUMBER,(765/√3) / (400/√3) / 33 KV, 1-PHASE, SPARE AUTO-TRANSFORMER UNIT) SET 1 Included
115 7000009390 1100 earthmat 1000011149 Material for Earthing of single phaseunits of Reactors and accessories likecooler bank, cooler control cabinets,common marshalling boxes, neturals, oneneutral CT, bus post insulators &structures required for neturalformation and spare unit connectionarrangement etc. for two banks completein all respect LOT 2 Included
116 7000009390 1110 earthmat 1000032992 MATERIAL FOR EARTHING OF SEVEN (7) NOS/ SIX (6) NOS.(AS APPLICABLE)SINGLE PHASE UNITS OF REACTORS (FORMING TWO NOS., 3-PH., REACTOR BANKSWITH ONE REACTOR UNIT AS COMMON SPARE(IF APPLICABLE)) AND ACCESSORIES,LIKE THEIR COOLER BANK, COOLER CONTROL CABINETS, COMMON MARSHALLING BOX,NEUTRALS, NEUTRAL CTS, BUS POST INSULATORS AND STRUCTURES REQUIRED FORNEUTRAL FORMATION AND SPARE UNIT CONNECTION ARRANGEMENT (IF APPLICABLE)ETC., COMPLETE IN ALL RESPECT. LS 1 Included
117 7000009390 1120 earthmat 1000030672 MATERIAL FOR EARTHING OF REACTOR TANK, ITS COOLER BANK (IF ERECTED)AND M. BOX. (FOR ONE NUMBER, 765KV/√3 KV, 1-PHASE, SPARE REACTOR UNIT) SET 2 Included
118 7000009390 1780 Neutral Formation 1000015788 Bus post insulators, spacers, equipmentsupport structures, conductors, Altube, clamp, connectors (including765kV, 400kV, tertiary and neuturalbushing terminal connectors etc) forarrangement of netural formation forTransformer(s), DELTA formation for onebank (each bank comprises of 3 singlephase units of Autotransformers) andmaking connection arrangement toconnect spare unit in place of any unitof the bank without physical shifting LOT 2 Included
119 7000009390 1790 Neutral Formation 1000015929 Bus post insulators, spacers, equipmentsupport structures, conductor(s), Altube, clamp, connectors including 765KV and neutral bushings terminalconnectors etc for Neutral formationfor two banks (each bank comprise ofthree single phase units of Reactors)and connection to two neutral groundingreactors and making connectionarrengment to connect spare unit inplace of any unit of all the two bankswithout physical shifting. LOT 2 Included
120 7000009390 1800 Neutral Formation 1000015928 Bus post insulators, spacers, equipment support structures includingfoundation bolts,conductor(s), Al tube, clamp, connectors including 765KV and neutral bushings terminal connectors etc for Neutral formationfor two (2) Reactor banks (each bank comprise of three single phaseunits of Reactors) and connection to two (2) neutral grounding Reactorsand making connection arrangement to connect spare unit in place of anyunit of all the two banks without pysical shifting LOT 1 Included
121 7000009390 1130 lattice structure 1000020180 Fabrication, galvanising and supply of Std 765 kV Tower CA includingnuts, bolts, all type of washers, packplates, step bolts and gussetplates excluding foundation bolts EA 28 Included
122 7000009390 1140 lattice structure 1000020162 Fabrication, galvanising and supply of Std 765 kV Beam BA includingnuts, bolts, all type of washers, packplates, step bolts and gussetplates excluding foundation bolts EA 14 Included
123 7000009390 1150 lattice structure 1000020163 Fabrication, galvanising and supply of Std 765 kV Beam BB includingnuts, bolts, all type of washers, packplates, step bolts and gussetplates excluding foundation bolts EA 28 Included
124 7000009390 1160 lattice structure 1000020181 Fabrication, galvanising and supply of Std 765 kV Tower CB includingnuts, bolts, all type of washers, packplates, step bolts and gussetplates excluding foundation bolts EA 48 Included
125 7000009390 1170 lattice structure 1000020164 Fabrication, galvanising and supply of Std 765 kV Beam BC includingnuts, bolts, all type of washers, packplates, step bolts and gussetplates excluding foundation bolts EA 24 Included
126 7000009390 1180 lattice structure 1000020165 Fabrication, galvanising and supply of Std 765 kV Beam BD includingnuts, bolts, all type of washers, packplates, step bolts and gussetplates excluding foundation bolts EA 48 Included
127 7000009390 1190 lattice structure 1000020158 Fabrication, galvanising and supply of Std 765 kV Arm GWCB includingnuts, bolts, all type of washers, packplates, step bolts and gussetplates excluding foundation bolts EA 48 Included
128 7000009390 1200 lattice structure 1000020182 Fabrication, galvanising and supply of Std 765 kV Tower CC includingnuts, bolts, all type of washers, packplates, step bolts and gussetplates excluding foundation bolts EA 16 Included
129 7000009390 1210 lattice structure 1000020166 Fabrication, galvanising and supply of Std 765 kV Beam BE includingnuts, bolts, all type of washers, packplates, step bolts and gussetplates excluding foundation bolts EA 8 Included
130 7000009390 1220 lattice structure 1000020167 Fabrication, galvanising and supply of Std 765 kV Beam BF includingnuts, bolts, all type of washers, packplates, step bolts and gussetplates excluding foundation bolts EA 16 Included
131 7000009390 1230 lattice structure 1000020159 Fabrication, galvanising and supply of Std 765 kV Arm GWCC includingnuts, bolts, all type of washers, packplates, step bolts and gussetplates excluding foundation bolts EA 16 Included
132 7000009390 1240 lattice structure 1000020125 Fabrication, galvanising and supply of Standard 400 kV Tower TCincluding nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts EA 6 Included
133 7000009390 1250 lattice structure 1000020130 Fabrication, galvanising and supply of Standard 400 kV Tower THincluding nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts EA 4 Included
134 7000009390 1260 lattice structure 1000020132 Fabrication, galvanising and supply of Standard 400 kV Tower TJincluding nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts EA 10 Included
135 7000009390 1270 lattice structure 1000020136 Fabrication, galvanising and supply of Standard 400 kV Tower TNincluding nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts EA 6 Included
136 7000009390 1280 lattice structure 1000020118 Fabrication, galvanising and supply of Standard 400 kV Gantry G1including nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts EA 8 Included
137 7000009390 1290 lattice structure 1000020119 Fabrication, galvanising and supply of Standard 400 kV Gantry G2including nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts EA 14 Included
138 7000009390 1300 lattice structure 1000020175 Fabrication, galvanising and supply ofStd 765 kV Support Structure for1-Phase CT including nuts, bolts, alltype of washers, packplates, step boltsand gusset plates excluding foundationbolts EA 42 Included
139 7000009390 1310 lattice structure 1000020176 Fabrication, galvanising and supply ofStd 765 kV Support Structure for1-Phase CVT including nuts, bolts, alltype of washers, packplates, step boltsand gusset plates excluding foundationbolts EA 18 Included
140 7000009390 1320 lattice structure 1000020177 Fabrication, galvanising and supply ofStd 765 kV Support Structure for3-Phase ISOLATOR including nuts, bolts,all type of washers, packplates, stepbolts and gusset plates excludingfoundation bolts EA 36 Included
141 7000009390 1330 lattice structure 1000030445 FABRICATION, GALVANISING AND SUPPLY OFSTD 765 KV SUPPORT STRUCTURE FOR1-PHASE ISOLATOR INCLUDING NUTS,BOLTS, ALL TYPE OF WASHERS, PACKPLATES,STEP BOLTS AND GUSSET PLATES EXCLUDINGFOUNDATION BOLTS EA 72 Included
142 7000009390 1340 lattice structure 1000020178 Fabrication, galvanising and supply ofStd 765 kV Support Structure for1-Phase LA including nuts, bolts, alltype of washers, packplates, step boltsand gusset plates excluding foundationbolts EA 39 Included
143 7000009390 1350 lattice structure 1000020174 Fabrication, galvanising and supply ofStd 765 kV Support Structure for1-Phase BPI including nuts, bolts, alltype of washers, packplates, step boltsand gusset plates excluding foundationbolts EA 90 Included
144 7000009390 1360 lattice structure 1000020185 Fabrication, galvanising and supply of 33kV Std Double Pole Structureincluding nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts EA 1 Included
145 7000009390 1370 PIPE STRUCTURE 1000020192 Fabrication, galvanising and supply ofStandard Pipe Structure - 400 kV,1-Phase, CT including nuts, bolts, alltype of washers, packplates, step boltsand gusset plates excluding foundationbolts EA 24 Included
146 7000009390 1380 PIPE STRUCTURE 1000020193 Fabrication, galvanising and supply of Standard Pipe Structure - 400kV CVT including nuts, bolts, all type of washers, packplates, stepbolts and gusset plates excluding foundation bolts EA 12 Included
147 7000009390 1390 PIPE STRUCTURE 1000020194 Fabrication, galvanising and supply ofStandard Pipe Structure - 400 kV,3-Phase, ISOLATOR including nuts,bolts, all type of washers, packplates,step bolts and gusset plates excludingfoundation bolts EA 20 Included
148 7000009390 1400 PIPE STRUCTURE 1000020195 Fabrication, galvanising and supply ofStandard Pipe Structure - 400 kV,1-Phase, SA including nuts, bolts,all type of washers, packplates, stepbolts and gusset plates excludingfoundation bolts EA 16 Included
149 7000009390 1410 PIPE STRUCTURE 1000020196 Fabrication, galvanising and supply ofStd Pipe Structure - 400 kV, 1-Phase,BPI, (Excluding Wave Trap), includingnuts, bolts, all type of washers,packplates, step bolts and gussetplates excluding foundation bolts EA 30 Included
150 7000009390 1420 PIPE STRUCTURE 1000029057 Fabrication, galvanising and supply of Std 72.5 kV Support Structure1Ph CT including nuts, bolts, all type of washers, packplates, stepboltsand gusset plates excluding foundation bolts EA 3 Included
151 7000009390 1430 PIPE STRUCTURE 1000029058 Fabrication, galvanising and supply of Std 72.5 kV Support Structure1Ph CVT including nuts, bolts, all type of washers, packplates, stepboltsand gusset plates excluding foundation bolts EA 3 Included
152 7000009390 1440 PIPE STRUCTURE 1000030444 FABRICATION, GALVANISING AND SUPPLY OF STD 72.5 KV SUPPORT STRUCTUREISO 1 - PH INCLUDING NUTS, BOLTS, ALL TYPE OF WASHERS, PACKPLATES,STEP BOLTS AND GUSSET PLATES EXCLUDING FOUNDATION BOLTS EA 6 Included
153 7000009390 1450 PIPE STRUCTURE 1000017570 Fabrication, galvanising and supply ofStd Pipe Structure - 400 kV, 1-Phase,High BPI, (Excluding Wave Trap), includingnuts, bolts, all type of washers,packplates, step bolts and gussetplates excluding foundation bolts EA 30 Included
154 7000009390 1460 PIPE STRUCTURE 1000030447 FABRICATION, GALVANISING AND SUPPLY OFSTANDARD PIPE STRUCTURE - 400 KVISOLATOR, 1 - PHASE, INCLUDING NUTS,BOLTS, ALL TYPE OF WASHERS, PACKPLATES,STEP BOLTS AND GUSSET PLATES EXCLUDINGFOUNDATION BOLTS EA 12 Included
155 7000009390 2640 PIPE STRUCTURE 1000029056 Fabrication, galvanising and supply of Std 72.5 kV Support Structure1Ph BPI including nuts, bolts, all type of washers, packplates, stepboltsand gusset plates excluding foundation bolts EA 6 Included
156 7000009390 1470 ERECTION HARDWARE 1000011358 Erection Hardware for 765kV I type layout-Line bay as per technicalspecification SET 4 Included
157 7000009390 1480 ERECTION HARDWARE 1000011363 Erection Hardware for 765kV I type layout-Transformer bay as pertechnical specification SET 2 Included
158 7000009390 1490 ERECTION HARDWARE 1000011349 Erection Hardware for 765kV I type layout-Bus Reactor bay as pertechnical specification SET 2 Included
159 7000009390 1500 ERECTION HARDWARE 1000011362 Erection Hardware for 765kV I type layout-Spare bay of half dia. asper technical specification SET 2 Included
160 7000009390 1510 ERECTION HARDWARE 1000011357 Erection Hardware for 765kV I type layout-Line Reactors including NGRbypassing arrangement as per technical specification SET 4 Included
161 7000009390 1520 ERECTION HARDWARE 1000011322 Erection Hardware for 400kV I type layout-Line bay as per technicalspecification SET 2 Included
162 7000009390 1530 ERECTION HARDWARE 1000011327 Erection Hardware for 400kV I type layout-Transformer bay as pertechnical specification SET 2 Included
163 7000009390 1540 ERECTION HARDWARE 1000011317 Erection Hardware for 400kV I type layout-Bus Reactor bay as pertechnical specification SET 1 Included
164 7000009390 1550 ERECTION HARDWARE 1000011326 Erection Hardware for 400kV I type layout-Spare bay of half dia as pertechnical specification SET 1 Included
165 7000009390 1560 ERECTION HARDWARE 1000011319 Erection Hardware for 400kV I type layout-Bus Work (For two diameters)as per technical specification SET 2 Included
166 7000009390 1570 ERECTION HARDWARE 1000030546 Erection Hardware for the 72.5kV and 36kV equipment (scheme as perSLD) SET 1 Included
167 7000009390 1580 ERECTION HARDWARE 1000011350 Erection Hardware for 765kV I type layout-Bus Work (For one diameters)as per technical specification SET 6 Included
168 7000009390 1590 145 kV Equipment 1000000945 145kV, 1250A, 31.5KA Circuit Breakers(1-Phase) with support structure EA 4 Included
169 7000009390 1600 765 kV CB spares 1000027625 Spare-765KV Circuit Breaker LOT 1 Included
170 7000009390 1610 765 kV Isoator spares 1000028091 Spare-765kV VKDB Isolator LOT 1 Included
171 7000009390 1620 765 kV CT spares 1000026479 Additional Spares for 765kV CT EA 1 Included
172 7000009390 1630 765 kV CVT spares 1000026480 Additional Spares for 765kV CVT EA 1 Included
173 7000009390 1690 624 kV Surge arrester spares 1000020441 Surge monitor for 624 kV Surge Arrester (1-Phase) EA 5 Included
174 7000009390 1700 624 kV Surge arrester spares 1000020421 624kV Surge Arrester (1-Phase) EA 1 Included
175 7000009390 1650 420 kV CB spares 1000019918 Spares for 420kV Circuit Breaker LS 1 Included
176 7000009390 1660 420 kV Isolator spares 1000019919 Spares for 420kV Double break Isolator LS 1 Included
177 7000009390 1670 420 kV CT spares 1000025941 Spare-420kV CT 1 SET 1 Included
178 7000009390 1680 420 kV CVT spares 1000025943 Spare-420kV CVT 1 SET 1 Included
179 7000009390 1710 336 kV Surge Arrester spares 1000024186 SPARES FOR 336KV SURGE ARRESTER LS 1 Included
180 7000009390 1720 220 V Battery Charger spares 1000019914 Spares fpr 220V Battery Charger LS 1 Included
181 7000009390 1730 48 V Battery Charger spares 1000019921 Spares fpr 48V Battery Charger LS 1 Included
182 7000009390 1740 fire protection system spares 1000019925 Spares for Fire Protection System LS 1 Included
183 7000009390 1750 DG Set spares 1000019915 Spares for DG set LS 1 Included
184 7000009390 1760 C&P and SCADA spares 1000019912 Relay & protection Panels (with automation) LS 1 Included
185 7000009390 1770 C&P and SCADA spares 1000019927 Spares-Substation Automation System LS 1 Included
186 7000009390 2060 Non Standard Structure 1000015954 Fabrication, galvanising and supply of Lattice Structures (MS Steel),to be designed during detailed engineering, for towers, beams andequipment support structure including pack plates / packwashers andgusset plates excluding fasteners and foundation bolts MT 17 Included
187 7000009390 2070 Non Standard Structure 1000015952 Fabrication, galvanising and supply of Equipment Support (Pipe)Structures to be designed during detailed engineering MT 15.2 Included
188 7000009390 2080 Non Standard Structure 1000011713 Fabrication, galvanising and supply of fasteners ( nuts, bolts andwashers ) including step bolts for lattice and pipe structures to bedesigned during detailed engineering MT 1 Included
189 7000009390 2090 Non Standard Structure 1000012373 Fabrication, galvanising and supply of foundation bolts including nuts,checknut and washers for lattice and pipe structures to be designedduring detailed engineering MT 2.7 Included
190 7000009390 2110 Foundation Bolts 1000012366 Fabrication, galvanising and supply of 28mm dia foundation boltsincluding nuts, checknuts, washers and packplates. EA 1060 Included
191 7000009390 2120 Foundation Bolts 1000012367 Fabrication, galvanising and supply of 32mm dia foundation boltsincluding nuts, checknuts, washers and packplates EA 6348 Included
192 7000009390 2130 Foundation Bolts 1000012369 Fabrication, galvanising and supply of 56mm dia foundation boltsincluding nuts, checknuts, washers and packplates EA 768 Included
193 7000009390 2140 Foundation Bolts 1000012371 Fabrication, galvanising and supply of 80mm dia foundation boltsincluding nuts, checknuts, washers and packplates EA 1024 Included
194 7000009390 2150 765kV pmu and associated equip. 1000017518 PMU with GPS Clock (clock can be either internal or external) EA 4 Included
195 7000009390 2160 765kV pmu and associated equip. 1000022512 WAMS Hardware - Time System (GPS receiver) EA 4 Included
196 7000009390 2170 765kV pmu and associated equip. 1000022510 WAMS Hardware - Substation Grade Layer-3 LAN Switches with minimum 4 x10/100 Mbps Ethernet ports and 2 x 1 Gbps Ethernet ports EA 5 Included
197 7000009390 2180 765kV pmu and associated equip. 1000022487 WAMS Miscellaneous - Armored Fibre Optic Cable and associatedtermination (e.g. L2 Switch) for connecting PMU panels located indifferent control room of a station EA 1 Included
198 7000009390 2200 400 kV PMU and associated equip. 1000017518 PMU with GPS Clock (clock can be either internal or external) EA 2 Included
199 7000009390 2210 400 kV PMU and associated equip. 1000022512 WAMS Hardware - Time System (GPS receiver) EA 2 Included
200 7000009390 2220 400 kV PMU and associated equip. 1000022510 WAMS Hardware - Substation Grade Layer-3 LAN Switches with minimum 4 x10/100 Mbps Ethernet ports and 2 x 1 Gbps Ethernet ports EA 3 Included
201 7000009390 2230 400 kV PMU and associated equip. 1000022487 WAMS Miscellaneous - Armored Fibre Optic Cable and associatedtermination (e.g. L2 Switch) for connecting PMU panels located indifferent control room of a station EA 1 Included
202 7000009390 2250 Tele equipment at Bhadla-2 incl repeater 1000031367 SDH EQUIPMENT (STM-16 MADM UPTO 5 MSP PROTECTED DIRECTIONS)-BASEEQUIPMENT (COMMON CARDS, CROSS CONNECT/CONTROL CARDS, OPTICAL BASECARDS, POWER SUPPLY CARDS, POWER CABLING, OTHER HARDWARE ANDACCESSORIES INCLUDING SUB RACKS, PATCH CORD, DDF ETC FULLY EQUIPEDEXCLUDING OPTICAL INTERFACE & TRIBUTARY CARDS EA 2 Included
203 7000009390 2260 Tele equipment at Bhadla-2 incl repeater 1000031881 SDH EQUIPMENT (STM-16 MADM UPTO 3 MSP PROTECTED DIRECTIONS)-BASEEQUIPMENT (COMMON CARDS, CROSS CONNECT/CONTROL CARDS, OPTICAL BASECARDS, POWER SUPPLY CARDS, POWER CABLING, OTHER HARDWARE ANDACCESSORIES INCLUDING SUB RACKS, PATCH CORD, DDF ETC FULLY EQUIPEDEXCLUDING OPTICAL INTERFACE & TRIBUTARY CARDS EA 1 Included
204 7000009390 2270 Tele equipment at Bhadla-2 incl repeater 1000018706 S16.1 SFP EA 4 Included
205 7000009390 2410 Tele equipment at Bhadla-2 incl repeater 1000014272 L16.1 SFP EA 2 Included
206 7000009390 2280 Tele equipment at Bhadla-2 incl repeater 1000014273 L16.2 SFP EA 2 Included
207 7000009390 2290 Tele equipment at Bhadla-2 incl repeater 1000019315 Optical Line Interface card (to support minimum 150 kms) EA 2 Included
208 7000009390 2300 Tele equipment at Bhadla-2 incl repeater 1000019317 Optical Line Interface card To support minimum 175 km EA 2 Included
209 7000009390 2310 Tele equipment at Bhadla-2 incl repeater 1000019316 Optical Line Interface card To support minimum 200 km EA 4 Included
210 7000009390 2320 Tele equipment at Bhadla-2 incl repeater 1000031405 OPTICAL INTERFACE CARD (TO SUPPORT MINIMUM 225 KMS) FOR STM-16 EA 4 Included
211 7000009390 2330 Tele equipment at Bhadla-2 incl repeater 1000031374 TRIBUTARY INTERFACE- E1 INTERFACE (MINIMUM 16 NOS.) SET 4 Included
212 7000009390 2340 Tele equipment at Bhadla-2 incl repeater 1000034950 ETHERNET INTERFACE 10/100 BASE T WITH LAYER-2 SWITCHING (MIN 8INTERFACES PER CARD) EA 4 Included
213 7000009390 2350 Tele equipment at Bhadla-2 incl repeater 1000031381 TRIBUTARY INTERFACE-GIGABIT ETHERNET INTERFACES 10/100 MBPS WITH LAYER-2 SWITCHING (MINIMUM 2 NOS.) SET 2 Included
214 7000009390 2360 Tele equipment at Bhadla-2 incl repeater 1000026228 Equipment Cabinets For SDH EA 3 Included
215 7000009390 2370 Tele equipment at Bhadla-2 incl repeater 1000028495 NMS- CRAFT TERMINAL-HARDWARE EA 2 Included
216 7000009390 2380 Tele equipment at Bhadla-2 incl repeater 1000028265 Software for Craft Terminal EA 2 Included
217 7000009390 2390 Tele equipment at Bhadla-2 incl repeater 1000034998 VOIP TELEPHONE INSTRUMENT WITH ONE COMMON SWITCH (MIN. 8 PORT) EA 8 Included
218 7000009390 2400 Tele equipment at Bhadla-2 incl repeater 1000031403 REPEATER SHELTER SYSTEM INCLUDING ALL SHELTER ITEMS SUCH ASAIR-CONDITIONER, DG SETS, STATIC VOLTAGE STABLISER, DCPS & BATTERY ETC AS PER TECHNICAL SPECIFICATION OF PUF INSULATED PRE-COATED STEELSHELTER (INNER DIMENSION : 4340 X 2540 X 3000 MM & OUTER DIMENSION4500 X 2700 X 3160 MM) SET 1 Included
219 7000009390 2420 spares of tele eqpt at Bhadla-2 incl rep 1000031369 SDH EQUIPMENT (STM-16 MADM UPTO 5 MSP PROTECTED DIRECTIONS)-COMMONCARDS, CROSS-CONNECT/CONTROL CARDS, OPTICAL BASE CARD, POWER SUPPLYCARDS, POWER CABLING, OTHER HARDWARE & ACCESSORIES (EACH). SET 1 Included
220 7000009390 2430 spares of tele eqpt at Bhadla-2 incl rep 1000018706 S16.1 SFP EA 1 Included
221 7000009390 2540 spares of tele eqpt at Bhadla-2 incl rep 1000014272 L16.1 SFP EA 1 Included
222 7000009390 2440 spares of tele eqpt at Bhadla-2 incl rep 1000014273 L16.2 SFP EA 1 Included
223 7000009390 2450 spares of tele eqpt at Bhadla-2 incl rep 1000019315 Optical Line Interface card (to support minimum 150 kms) EA 1 Included
224 7000009390 2460 spares of tele eqpt at Bhadla-2 incl rep 1000019317 Optical Line Interface card To support minimum 175 km EA 1 Included
225 7000009390 2470 spares of tele eqpt at Bhadla-2 incl rep 1000019316 Optical Line Interface card To support minimum 200 km EA 1 Included
226 7000009390 2530 spares of tele eqpt at Bhadla-2 incl rep 1000031405 OPTICAL INTERFACE CARD (TO SUPPORT MINIMUM 225 KMS) FOR STM-16 EA 1 Included
227 7000009390 2480 spares of tele eqpt at Bhadla-2 incl rep 1000031374 TRIBUTARY INTERFACE- E1 INTERFACE (MINIMUM 16 NOS.) SET 1 Included
228 7000009390 2490 spares of tele eqpt at Bhadla-2 incl rep 1000034950 ETHERNET INTERFACE 10/100 BASE T WITH LAYER-2 SWITCHING (MIN 8INTERFACES PER CARD) EA 1 Included
229 7000009390 2500 spares of tele eqpt at Bhadla-2 incl rep 1000031381 TRIBUTARY INTERFACE-GIGABIT ETHERNET INTERFACES 10/100 MBPS WITH LAYER-2 SWITCHING (MINIMUM 2 NOS.) SET 1 Included
230 7000009390 2510 spares of tele eqpt at Bhadla-2 incl rep 1000034998 VOIP TELEPHONE INSTRUMENT WITH ONE COMMON SWITCH (MIN. 8 PORT) EA 1 Included
231 7000009390 2520 spares of tele eqpt at Bhadla-2 incl rep 1000031398 PRE CONNECTORIZED OPTICAL FIBER PATCH CORDS(10 MTRS) – PACK OF SIXPATCH CORDS SET 1 Included
Total F&I Price 0.00
Place: Printed Name :
CC-CS/912-NR1/SS-3933/3/G10 (SS29) Schedule - 2 Dis
AIS Substation Package-SS29 Establishment of 765/400kV Bhadla-II PS (Jodhpur) new S/S under Transmission Scheme for Solar Energy Zones in Rajasthan As per Lum-sum 0
(SCHEDULE OF RATES AND PRICES : FREIGHT & INSURANCE CHARGES) AS per Percent #REF!
As per lum-sum on Sch-2 0.00%
Bidder’s Name and Address (Lead Partner) : To: As per Percent on Sch-2 #REF!
Contracts Services, 3rd Floor Total Discount #REF!
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Sector-29, Multipackage Discount 0.00%
Gurgaon (Haryana) - 122001
All Prices are in Indian Rupees. Amount after Discount (Rs.) Dis Alert Amount after MPD (Rs.)
SI. No. Description Unit Quantity Unit Freight & Insurance Charges Total Freight & Insurance Charges Unit Freight & Insurance Charges Total Freight & Insurance Charges Unit Freight & Insurance Charges Total Freight & Insurance Charges
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
Total F&I Price #REF!
Place : Printed Name :
CC-CS/912-NR1/SS-3933/3/G10 (SS29) Schedule - 3
AIS Substation Package-SS29 Establishment of 765/400kV Bhadla-II PS (Jodhpur) new S/S under Transmission Scheme for Solar Energy Zones in Rajasthan As per Lum-sum 0.00%
(SCHEDULE OF RATES AND PRICES ) AS per Percent #REF!
As per lum-sum on Sch-3 0.00%
Bidder’s Name and Address (Lead Partner) : To: As per Percent on Sch-3 #REF!
Contracts Services, 3rd Floor Total Discount #REF!
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Sector-29, Multipackage lum-sum 0.00%
Gurgaon (Haryana) - 122001
INSTALLATION CHARGES Amount after Discount (Rs.) Dis Alert Amount after MPD (Rs.)
All Prices are in Indian Rupees.
SI. No. PR No PR Line Item No Activity Header PR Activity No Activity Description Service Code SAC (Service Accounting Codes) Whether SAC in column '8’ is confirmed. If not indicate applicable the SAC * Rate of GST applicable ( in %) Whether rate of GST in column ‘4’ is confirmed. If not indicate applicable rate of GST * Description Unit Quantity Unit Charges Total Charges Total GST as confirmed by Bidder Unit Erection Charges Total Erection Charges Unit Erection Charges Total Erection Charges
I 220 KV SS EXT PKG-SS-25-LUCKNOW SS Revaluation of J column Tax Calculation
1 7000009390 1810 390 10 LT Transformer 100000081 998736 Confirmed 18% Confirmed 800kVA, 33/0.433kV, 3ph LT Transformer EA 2 Included 0.00 0 0.18 0
2 7000009390 1820 400 10 800kV Equipment 100002796 998736 Confirmed 18% Confirmed 765kV, 3150A, 40kA Circuit Breaker With Closing Resistor with Controlled switching device (with Support Structures) EA 2 Included 0.00 0 0.18 0
3 7000009390 1820 400 20 800kV Equipment 100000129 998736 Confirmed 18% Confirmed 765kV, 3150A, 40KA Circuit Breaker(3-Phase) with closing resistor (withsupport structure) EA 6 Included 0.00 0 0.18 0
4 7000009390 1820 400 30 800kV Equipment 100002797 998736 Confirmed 18% Confirmed 765kV, 3150A, 40kA Circuit Breaker Without Closing Resistor with Controlled switching device (with Support Structures) EA 10 Included 0.00 0 0.18 0
5 7000009390 1820 400 40 800kV Equipment 100002571 998736 Confirmed 18% Confirmed 765kV, 3150 A, 40kA 3 Phase Circuit Breaker without closing resistor with control switching suitable for 1-ph Reactor switching EA 2 Included 0.00 0 0.18 0
6 7000009390 1820 400 50 800kV Equipment 100000140 998736 Confirmed 18% Confirmed 765 kV, 3000A, 40KA, 1-Phase CurrentTransformer with 120% extended currentrating EA 42 Included 0.00 0 0.18 0
7 7000009390 1820 400 60 800kV Equipment 100000146 998736 Confirmed 18% Confirmed 765 kV,8800 pF Capacitive Voltage Transformer (1-Phase) EA 18 Included 0.00 0 0.18 0
8 7000009390 1820 400 70 800kV Equipment 100000166 998736 Confirmed 18% Confirmed 765kV, 3150A, 40 KA, VerticalKnee/Double Break Isolator (3-Phase)with one E/S EA 22 Included 0.00 0 0.18 0
9 7000009390 1820 400 80 800kV Equipment 100000167 998736 Confirmed 18% Confirmed 765kV, 3150A, 40 KA, VerticalKnee/Double Break Isolator (3-Phase)with two E/S EA 14 Included 0.00 0 0.18 0
10 7000009390 1820 400 90 800kV Equipment 100000173 998736 Confirmed 18% Confirmed 765kV, 2000A, 40 KA, VerticalKnee/Double Break Isolator (1-Phase)with one E/S EA 27 Included 0.00 0 0.18 0
11 7000009390 1820 400 100 800kV Equipment 100000175 998736 Confirmed 18% Confirmed 765kV, 2000A, 40 KA, VerticalKnee/Double Break Isolator (1-Phase)without E/S EA 45 Included 0.00 0 0.18 0
12 7000009390 1820 400 110 800kV Equipment 100000183 998736 Confirmed 18% Confirmed 624kV Surge Arrester (1-Phase) EA 39 Included 0.00 0 0.18 0
13 7000009390 1820 400 120 800kV Equipment 100000194 998736 Confirmed 18% Confirmed Erection of 765 kV, 1-Phase, Bus Post Insulator (except wave Traps) SET 90 Included 0.00 0 0.18 0
14 7000009390 1830 410 10 400kV Equipment 100000268 998736 Confirmed 18% Confirmed Controlled Switching Device for 420 kV, 3-ph Circuit Breaker EA 6 Included 0.00 0 0.18 0
15 7000009390 1830 410 30 400kV Equipment 100001898 998736 Confirmed 18% Confirmed 420kV, 3150A, 50kA Circuit Breaker(3-Phase) without closing resistor(withsupport structure) EA 8 Included 0.00 0 0.18 0
16 7000009390 1830 410 40 400kV Equipment 100000270 998736 Confirmed 18% Confirmed 420 kV, 3000A, 50KA, 1-Phase CurrentTransformer with 120% extended currentrating EA 24 Included 0.00 0 0.18 0
17 7000009390 1830 410 50 400kV Equipment 100000275 998736 Confirmed 18% Confirmed 420 kV, 4400 pF Capacitive Voltage Transformer (1-Phase) EA 12 Included 0.00 0 0.18 0
18 7000009390 1830 410 60 400kV Equipment 100000308 998736 Confirmed 18% Confirmed 420kV, 3150A, 50KA Isolator (3-phase)(Double Break) with two E/S EA 2 Included 0.00 0 0.18 0
19 7000009390 1830 410 70 400kV Equipment 100000307 998736 Confirmed 18% Confirmed 420kV, 3150A, 50KA, Isolator (3-phase)(Double Break) with one E/S EA 18 Included 0.00 0 0.18 0
20 7000009390 1830 410 80 400kV Equipment 100000314 998736 Confirmed 18% Confirmed 420kV, 2000A, 50 KA, Isolator (1 phase)(Double Break) with one E/S EA 7 Included 0.00 0 0.18 0
21 7000009390 1830 410 90 400kV Equipment 100000315 998736 Confirmed 18% Confirmed 420kV, 2000A, 50KA, Isolator (1 phase)(Double Break) without E/S EA 5 Included 0.00 0 0.18 0
22 7000009390 1830 410 110 400kV Equipment 100000328 998736 Confirmed 18% Confirmed 336kV Surge Arrester (1-phase) EA 16 Included 0.00 0 0.18 0
23 7000009390 1830 410 120 400kV Equipment 100000340 998736 Confirmed 18% Confirmed 420 kV Bus Post Insulator (Except for wave traps) EA 60 Included 0.00 0 0.18 0
24 7000009390 1840 430 10 72.5kV Equipment 100000612 998736 Confirmed 18% Confirmed 72.5 kV, 1250A, 31.5 kA, 3-phase CircuitBreaker with support structure EA 1 Included 0.00 0 0.18 0
25 7000009390 1840 430 20 72.5kV Equipment 100000618 998736 Confirmed 18% Confirmed 72.5 kV, 1500A, 31.5 kA, 1-Phase CurrentTransformer with 120% extended currentrating EA 3 Included 0.00 0 0.18 0
26 7000009390 1840 430 30 72.5kV Equipment 100000628 998736 Confirmed 18% Confirmed 72.5 kV, 1250A, 31.5 KA, 3-Phase HDBIsolator with one E/S EA 2 Included 0.00 0 0.18 0
27 7000009390 1840 430 40 72.5kV Equipment 100000624 998736 Confirmed 18% Confirmed 72.5 kV Voltage Transformer (1- Phase) EA 3 Included 0.00 0 0.18 0
28 7000009390 1840 430 50 72.5kV Equipment 100001909 998736 Confirmed 18% Confirmed 72.5kV, Bus Post Insulator, 1-Phase EA 6 Included 0.00 0 0.18 0
29 7000009390 1850 440 10 36kV Equipment 100000662 998736 Confirmed 18% Confirmed 36 kV, 1250A, 25 KA, 3-Phase DoubleBreak Isolator with one E/s EA 1 Included 0.00 0 0.18 0
30 7000009390 1850 440 20 36kV Equipment 100000669 998736 Confirmed 18% Confirmed 30kV Surge Arrester (1-Phase) EA 3 Included 0.00 0 0.18 0
31 7000009390 1850 440 30 36kV Equipment 100000670 998736 Confirmed 18% Confirmed 36kV,1-Ph Horn gap fuse with support structure EA 3 Included 0.00 0 0.18 0
32 7000009390 1860 450 10 Control & Relay panel- 765 kV 100000719 998736 Confirmed 18% Confirmed 765 kV Circuit Breaker Relay Panel With Auto Reclose (with Automation) EA 8 Included 0.00 0 0.18 0
33 7000009390 1860 450 20 Control & Relay panel- 765 kV 100000720 998736 Confirmed 18% Confirmed 765 kV Circuit Breaker Relay Panel without Auto Reclose (with Automation) EA 10 Included 0.00 0 0.18 0
34 7000009390 1860 450 30 Control & Relay panel- 765 kV 100000722 998736 Confirmed 18% Confirmed 765kV Line Protection Panel (with Automation) EA 4 Included 0.00 0 0.18 0
35 7000009390 1860 450 40 Control & Relay panel- 765 kV 100000723 998736 Confirmed 18% Confirmed 765kV Transformer Protection Panel (For both HV & MV side)-(with Automation) EA 2 Included 0.00 0 0.18 0
36 7000009390 1860 450 50 Control & Relay panel- 765 kV 100000724 998736 Confirmed 18% Confirmed 765kV Reactor Protection Panel (with Automation) EA 6 Included 0.00 0 0.18 0
37 7000009390 1860 450 60 Control & Relay panel- 765 kV 100000725 998736 Confirmed 18% Confirmed 765kV Bus Bar Protection Panel (Duplicate)-(with Automation) SET 1 Included 0.00 0 0.18 0
38 7000009390 1870 460 10 Control & Relay panel- 400 kV 100000728 998736 Confirmed 18% Confirmed 400kV Circuit Breaker Relay Panel with Auto Reclose (with Automation) EA 4 Included 0.00 0 0.18 0
39 7000009390 1870 460 20 Control & Relay panel- 400 kV 100000729 998736 Confirmed 18% Confirmed 400kV Circuit Breaker Relay Panel without Auto Reclose (with Automation) EA 4 Included 0.00 0 0.18 0
40 7000009390 1870 460 30 Control & Relay panel- 400 kV 100000730 998736 Confirmed 18% Confirmed 400kV Line Protection Panel (with Automation) EA 2 Included 0.00 0 0.18 0
41 7000009390 1870 460 40 Control & Relay panel- 400 kV 100000732 998736 Confirmed 18% Confirmed 400kV Reactor Protection Panel (with Automation) EA 1 Included 0.00 0 0.18 0
42 7000009390 1870 460 50 Control & Relay panel- 400 kV 100000733 998736 Confirmed 18% Confirmed 400kV Bus Bar Protection Panel (Duplicate)-(with Automation) SET 1 Included 0.00 0 0.18 0
43 7000009390 1880 480 10 Common Equipment 100001891 998736 Confirmed 18% Confirmed Time synchronisation equipment EA 1 Included 0.00 0 0.18 0
44 7000009390 1880 480 20 Common Equipment 100000869 998736 Confirmed 18% Confirmed Visual monitoring system for watch & ward SET 1 Included 0.00 0 0.18 0
45 7000009390 2600 481 10 DPC 100000891 998734 Confirmed 18% Confirmed Digital Protection Coupler EA 12 Included 0.00 0 0.18 0
46 7000009390 2600 481 20 DPC 100000892 998734 Confirmed 18% Confirmed EPAX (24/8) with 24 telephones, Cables etc. SET 1 Included 0.00 0 0.18 0
47 7000009390 2600 481 30 DPC 100002437 998734 Confirmed 18% Confirmed Telephone Instruments (4 wire/Express) alongwith cabling EA 8 Included 0.00 0 0.18 0
48 7000009390 2600 481 40 DPC 100002762 998734 Confirmed 18% Confirmed PLCC-Equipments-Telephone Instruments (2 wire) EA 15 Included 0.00 0 0.18 0
49 7000009390 1890 490 10 Substation Automation 100000770 998736 Confirmed 18% Confirmed Complete Substation automation system for 765kV Main bay as per Technical Specification EA 12 Included 0.00 0 0.18 0
50 7000009390 1890 490 20 Substation Automation 100000771 998736 Confirmed 18% Confirmed Complete Substation automation System for 400kV Main bay as per Technical Specification EA 6 Included 0.00 0 0.18 0
51 7000009390 1890 490 30 Substation Automation 100000776 998736 Confirmed 18% Confirmed Complete Substation automation System for 765kV Tie bay as per Technical Specification EA 2 Included 0.00 0 0.18 0
52 7000009390 1890 490 40 Substation Automation 100000778 998736 Confirmed 18% Confirmed Complete Substation automation System for 765kV Switchable Line Reactor Bay as per Technical Specification EA 4 Included 0.00 0 0.18 0
53 7000009390 1890 490 60 Substation Automation 100000783 998736 Confirmed 18% Confirmed Complete Substation automation System for controlling and monitoring of Auxilary System including BCUs as per technicalspecification SET 1 Included 0.00 0 0.18 0
54 7000009390 1890 490 50 Substation Automation 100000777 998736 Confirmed 18% Confirmed Complete Substation automation System for 400kV Tie bay as per Technical Specification EA 2 Included 0.00 0 0.18 0
55 7000009390 1900 510 10 LT Switchgear 100000894 998736 Confirmed 18% Confirmed 415V Main Switchboard SET 1 Included 0.00 0 0.18 0
56 7000009390 1900 510 20 LT Switchgear 100000895 998736 Confirmed 18% Confirmed AC Distribution Board (ACDB) SET 1 Included 0.00 0 0.18 0
57 7000009390 1900 510 30 LT Switchgear 100000897 998736 Confirmed 18% Confirmed 415V MLDB(along with 2 nos. 300 kVA Lighting transformer) SET 1 Included 0.00 0 0.18 0
58 7000009390 1900 510 40 LT Switchgear 100000899 998736 Confirmed 18% Confirmed 415V Emergency LDB(along with 1 no. 100kVA lighting transformer) SET 1 Included 0.00 0 0.18 0
59 7000009390 1900 510 50 LT Switchgear 100000901 998736 Confirmed 18% Confirmed 415V Airconditioning DB SET 1 Included 0.00 0 0.18 0
60 7000009390 1900 510 60 LT Switchgear 100000902 998736 Confirmed 18% Confirmed 220V DCDB SET 2 Included 0.00 0 0.18 0
61 7000009390 1900 510 70 LT Switchgear 100000905 998736 Confirmed 18% Confirmed 48V DCDB SET 2 Included 0.00 0 0.18 0
62 7000009390 1910 520 10 Battery & Battery Charger 100000915 998736 Confirmed 18% Confirmed 220V, 1500 Ah Battery SET 2 Included 0.00 0 0.18 0
63 7000009390 1910 520 20 Battery & Battery Charger 100000931 998736 Confirmed 18% Confirmed 48V, 1500 Ah Battery SET 2 Included 0.00 0 0.18 0
64 7000009390 1910 520 30 Battery & Battery Charger 100000940 998736 Confirmed 18% Confirmed 220V, 180A/180A Float Cum Boost BatteryCharger EA 2 Included 0.00 0 0.18 0
65 7000009390 1910 520 40 Battery & Battery Charger 100000955 998736 Confirmed 18% Confirmed 48V, 180A/180A Float Cum Boost BatteryCharger EA 2 Included 0.00 0 0.18 0
66 7000009390 1920 530 10 DG Set 100000956 998736 Confirmed 18% Confirmed 500 kVA Diesel Generator along with control Panel EA 1 Included 0.00 0 0.18 0
67 7000009390 1930 540 10 Air Condtioning System 100000960 995463 Confirmed 18% Confirmed High wall type split AC unit of 2 TR capacity EA 20 Included 0.00 0 0.18 0
68 7000009390 1930 540 30 Air Condtioning System 100001881 995463 Confirmed 18% Confirmed Air conditioning system for Switchyard Panel Room of 9m length SET 6 Included 0.00 0 0.18 0
69 7000009390 1930 540 40 Air Condtioning System 100001882 995463 Confirmed 18% Confirmed Air conditioning system for Switchyard Panel Room of 6m length SET 3 Included 0.00 0 0.18 0
70 7000009390 1940 550 10 Fire Protection System 100000966 998736 Confirmed 18% Confirmed Pumping arrangement for HVW system & hydrant system, complete with all piping, valves, fittings,etc. inside pump house for FireProtection System of 765/400/220kV (New) Substation SET 1 Included 0.00 0 0.18 0
71 7000009390 1940 550 20 Fire Protection System 100000969 998736 Confirmed 18% Confirmed Hydrant system, complete U/G piping and accessories etc. outside the Pump House for Fire Protection of 765/400/220kV (New)Substation SET 1 Included 0.00 0 0.18 0
72 7000009390 1940 550 30 Fire Protection System 100000972 998736 Confirmed 18% Confirmed 9litre water type Portable Fire extinguisher EA 4 Included 0.00 0 0.18 0
73 7000009390 1940 550 40 Fire Protection System 100000973 998736 Confirmed 18% Confirmed 50 litre foam type Trolley/Wheel mounted Fire extinguisher EA 2 Included 0.00 0 0.18 0
74 7000009390 1940 550 50 Fire Protection System 100000975 995461 Confirmed 18% Confirmed 4.5 kg CO2 type Portable Fire extinguisher EA 20 Included 0.00 0 0.18 0
75 7000009390 1940 550 60 Fire Protection System 100002752 998736 Confirmed 18% Confirmed 5Kg dry chemical powered type Portable Fire extinguisher EA 5 Included 0.00 0 0.18 0
76 7000009390 1940 550 100 Fire Protection System 100001010 998736 Confirmed 18% Confirmed HVW spray system, Hydrant system and complete U/G & O/G piping and accessories etc. out side the pump house for 125 MVAR, 420kV, 3phase Bus Reactor SET 1 Included 0.00 0 0.18 0
77 7000009390 1940 550 110 Fire Protection System 100000981 998736 Confirmed 18% Confirmed HVW spray system, Hydrant system and complete U/G & O/G piping and accessories etc. out side the pump house for 500 MVA,(765/v3)/(400/v3)/(33) kV, 1 -phase Autotransformer SET 7 Included 0.00 0 0.18 0
78 7000009390 1940 550 120 Fire Protection System 100001003 998736 Confirmed 18% Confirmed HVW spray system, Hydrant system and complete U/G & O/G piping and accessories etc. out side the pump house for 80 MVAR, 765/#3 kVSingle Phase shunt Reactor SET 7 Included 0.00 0 0.18 0
79 7000009390 1940 550 130 Fire Protection System 100001009 998736 Confirmed 18% Confirmed HVW spray system, Hydrant system and complete U/G & O/G piping and accessories etc. out side the pump house for 80 MVAR, 765 kV,single phase Bus Reactor SET 6 Included 0.00 0 0.18 0
80 7000009390 1940 550 150 Fire Protection System 100001002 998736 Confirmed 18% Confirmed HVW spray system, Hydrant system and complete U/G & O/G piping and accessories etc. out side the pump house for 110 MVAR, 765/#3 kVsingle phase Shunt Reactor SET 7 Included 0.00 0 0.18 0
81 7000009390 1940 550 160 Fire Protection System 100000980 995461 Confirmed 18% Confirmed Fire Detection and Alarm System for Control Room Building(765kV) SET 1 Included 0.00 0 0.18 0
82 7000009390 1940 550 170 Fire Protection System 100001871 995461 Confirmed 18% Confirmed Fire Detection and Alarm System for Switchyard Panel Room of 9 m length SET 6 Included 0.00 0 0.18 0
83 7000009390 1940 550 180 Fire Protection System 100002062 995461 Confirmed 18% Confirmed Fire Detection and Alarm System for Switchyard Panel Room of 6 m length SET 3 Included 0.00 0 0.18 0
84 7000009390 1950 560 10 Illumination System 100001021 995461 Confirmed 18% Confirmed Lighting Panel type ACP-2 as per technical specification EA 8 Included 0.00 0 0.18 0
85 7000009390 1950 560 20 Illumination System 100001022 998731 Confirmed 18% Confirmed Lighting Panel type ACP-3 as per technical specification EA 5 Included 0.00 0 0.18 0
86 7000009390 1950 560 30 Illumination System 100001024 998731 Confirmed 18% Confirmed Sub Lighting panel (outdoor) type SLP (Switchyard and Street Lighting) EA 15 Included 0.00 0 0.18 0
87 7000009390 1950 560 40 Illumination System 100001052 998731 Confirmed 18% Confirmed 63A, 415V : Interlocked switch socket outdoor Receptacle (type RP) as per technical specifications EA 8 Included 0.00 0 0.18 0
88 7000009390 1950 560 50 Illumination System 100001051 998731 Confirmed 18% Confirmed 15A, 240V: Outdoor Receptacle 2 pole, 3-pin modular (type RO) as per technical specifications EA 8 Included 0.00 0 0.18 0
89 7000009390 1950 560 70 Illumination System 100002441 998731 Confirmed 18% Confirmed Cartwheel mounted aluminium ladder as per technical specification EA 1 Included 0.00 0 0.18 0
90 7000009390 1950 560 90 Illumination System 100001087 998739 Confirmed 18% Confirmed Indoor Lighting for 10 cars Parking shed LS 1 Included 0.00 0 0.18 0
91 7000009390 1950 560 120 Illumination System 100001885 998739 Confirmed 18% Confirmed Outdoor Power Receptacle for oilfiltration unit (250A) EA 2 Included 0.00 0 0.18 0
92 7000009390 1950 560 190 Illumination System 100002750 998739 Confirmed 18% Confirmed Fire fighting pumphouse building and DG set area illimunation as per Tech. Spec. SET 1 Included 0.00 0 0.18 0
93 7000009390 1950 560 200 Illumination System 100001115 998739 Confirmed 18% Confirmed Illumination System for switchyard panel room of 9 m length SET 6 Included 0.00 0 0.18 0
94 7000009390 1950 560 220 Illumination System 100004931 998731 Confirmed 18% Confirmed LED Flood Light Luminaries Type FL-2 (250W) as per technical specification EA 400 Included 0.00 0 0.18 0
95 7000009390 1950 560 230 Illumination System 100004937 998731 Confirmed 18% Confirmed Fire Wall Mounted LED Luminarie Type FL-2 (250W) EA 52 Included 0.00 0 0.18 0
96 7000009390 1950 560 240 Illumination System 100004936 998731 Confirmed 18% Confirmed Portable Flood Light Panel with LED LuminariesType FL-2 (250W) EA 2 Included 0.00 0 0.18 0
97 7000009390 1950 560 250 Illumination System 100004933 998731 Confirmed 18% Confirmed Pole Mounted LED Post Top Luminaire TYPE SL-D1 (= 30W)as per technical specification EA 80 Included 0.00 0 0.18 0
98 7000009390 1950 560 260 Illumination System 100004932 998731 Confirmed 18% Confirmed LED Street Light Luminaire TYPE SL-L1 (= 45W)as per technical specification EA 250 Included 0.00 0 0.18 0
99 7000009390 1950 560 270 Illumination System 100004935 998731 Confirmed 18% Confirmed Type D1 Post top lantern pole of 4 meter as per technical specification. EA 80 Included 0.00 0 0.18 0
100 7000009390 1950 560 280 Illumination System 100004934 998731 Confirmed 18% Confirmed Type L1 Street Lighting Pole of 6 meter as per technical specification. EA 250 Included 0.00 0 0.18 0
101 7000009390 1950 560 290 Illumination System 100002771 998731 Confirmed 18% Confirmed Outdoor Power Receptacle for oil filtration unit (400A) EA 4 Included 0.00 0 0.18 0
102 7000009390 1950 560 219 Illumination System 100001116 998739 Confirmed 18% Confirmed Illumination System for switchyard panel room of 6 m length SET 3 Included 0.00 0 0.18 0
103 7000009390 1950 560 300 Illumination System 100001118 998739 Confirmed 18% Confirmed Control room cum administrative building (765kV) illumination including Conduit LOT 1 Included 0.00 0 0.18 0
104 7000009390 1950 560 310 Illumination System 100004938 998731 Confirmed 18% Confirmed GRID INTERACTIVE SOLAR PV POWER PLANT as per technical specification LS 1 Included 0.00 0 0.18 0
105 7000009390 1950 560 320 Illumination System 100001085 998739 Confirmed 18% Confirmed Indoor Lighting for Transit camp including Conduit LS 1 Included 0.00 0 0.18 0
106 7000009390 1960 570 10 Power & Control Cable 100002180 998736 Confirmed 18% Confirmed 1.1kV grade Power Cables (XLPEinsulated) along withlugs,glands,straight joints &accessories,etc. LS 1 Included 0.00 0 0.18 0
107 7000009390 1960 570 20 Power & Control Cable 100002181 998736 Confirmed 18% Confirmed 1.1kV grade Power Cables (PVCinsulated)along withlugs,glands,straight joints &accessories,etc. LS 1 Included 0.00 0 0.18 0
108 7000009390 1960 570 30 Power & Control Cable 100002182 998736 Confirmed 18% Confirmed 1.1kV grade Control Cables (PVCinsulated) along withlugs,glands,straight joints &accessories,etc. LS 1 Included 0.00 0 0.18 0
109 7000009390 1960 570 40 Power & Control Cable 100003094 998736 Confirmed 18% Confirmed 33KV GRADE HT XLPE CABLE ALONG WITH CLAMPS,LUGS, GLANDS AND STRAIGHT JOINTS. KM 1 Included 0.00 0 0.18 0
110 7000009390 1960 570 50 Power & Control Cable 100003022 998736 Confirmed 18% Confirmed 66kV HV Power Cable along with accessories KM 1 Included 0.00 0 0.18 0
111 7000009390 1970 590 10 Earthmat 100003103 998731 Confirmed 18% Confirmed 40 mm MS rod for Main Earthmat KM 40 Included 0.00 0 0.18 0
112 7000009390 1970 590 20 Earthmat 100000007 998736 Confirmed 18% Confirmed Material for Earthing of three single phase units of autotransformer and accessories like cooler bank, cooler control cabinets,common marshalling boxes, local OLTC boxes, neturals, netural CTs, bus post insulators & structures required for netural formationand DELTA formation and spare unit connection arrangement etc. complete in all respect. LOT 2 Included 0.00 0 0.18 0
113 7000009390 1970 590 30 Earthmat 100003113 998736 Confirmed 18% Confirmed Necessary arrangement for earthing from top of bushing to ground of 500MVA, 765/400/33kV, Spare Auto-transformer (not in service).Also Material for earthing of autotransformer tank, its cooler bank, cooler control cabinet and local OLTC box. SET 1 Included 0.00 0 0.18 0
114 7000009390 1970 590 40 Earthmat 100001954 998736 Confirmed 18% Confirmed Material for Earthing of single phase units of Reactors and accessories like cooler bank, cooler control cabinets, commonmarshalling boxes, neturals, one neutral CT, bus post insulators & structures required for netural formation and spare unitconnection arrangement etc. for two banks complete in all respect LOT 2 Included 0.00 0 0.18 0
115 7000009390 1970 590 50 Earthmat 100002629 998736 Confirmed 18% Confirmed Material for earthing of Reactor tank, its Cooler bank (if erected) and M. Box. (for One Number, 765kV/#3 kV, 1-Phase, Spare ReactorUnit) SET 2 Included 0.00 0 0.18 0
116 7000009390 1970 590 60 Earthmat 100003691 998736 Confirmed 18% Confirmed MATERIAL FOR EARTHING OF SEVEN (7) NOS/ SIX (6) NOS.(AS APPLICABLE) SINGLE PHASE UNITS OF REACTORS (FORMING TWO NOS., 3-PH.,REACTOR BANKS WITH ONE REACTOR UNIT AS COMMON SPARE(IF APPLICABLE)) AND ACCESSORIES, LIKE THEIR COOLER BANK, COOLER CONTROLCABINETS, COMMON MARSHALLING BOX, NEUTRALS, NEUTRAL CTS, BUS POST INSULATORS AND STRUCTURES REQUIRED FOR NEUTRAL FORMATION AND SPAREUNIT CONNECTION ARRANGEMENT (IF APPLICABLE) ETC., COMPLETE IN ALL RESPECT. SET 1 Included 0.00 0 0.18 0
117 7000009390 1980 600 40 Neutral Formation 100000005 998736 Confirmed 18% Confirmed Bus post insulators, spacers, equipment support structures, conductors, Al tube, clamp, connectors (including 765kV, 400kV, tertiaryand neutural bushing terminal connectors etc) for arrangement of netural formation for Transformer(s), DELTA formation for one bank(each bank comprises of 3 single phase units of Autotransformers) and making connection arrangement to connect spare unit in placeof any unit of the bank without physical shifting LOT 2 Included 0.00 0 0.18 0
118 7000009390 1980 600 50 Neutral Formation 100003629 998736 Confirmed 18% Confirmed Bus post insulators, spacers, equipment support structures, conductor(s), Al tube, clamp, connectors including 765 KV and neutral bushings terminal connectors etc for Neutral formation for two banks (each bank comprise of three single phase units of Reactors) andconnection to two neutral grounding reactors and making connection arrengment to connect spare unit in place of any unit of all thetwo banks without physical shifting LOT 2 Included 0.00 0 0.18 0
119 7000009390 1980 600 60 Neutral Formation 100001957 998736 Confirmed 18% Confirmed Bus post insulators, spacers, equipment support structures, conductor(s), Al tube, clamp, connectors including 765 KV and neutralbushings terminal connectors etc for Neutral formation for two banks (each bank comprise of three single phase units of Reactors)and connection to two neutral grounding reactors and making connection arrengment to connect spare unit in place of any unit of allthe two banks without physical shifting. LOT 1 Included 0.00 0 0.18 0
120 7000009390 1990 610 10 Lattice Structure 100001640 995455 Confirmed 18% Confirmed Erection of Std 765 kV Tower CA including nuts, bolts, all type of washers, packplates, step bolts and gusset plates excludingfoundation bolts EA 28 Included 0.00 0 0.18 0
121 7000009390 1990 610 20 Lattice Structure 100001645 995455 Confirmed 18% Confirmed Erection of Std 765 kV Beam BA including nuts, bolts, all type of washers, packplates, step bolts and gusset plates excludingfoundation bolts EA 14 Included 0.00 0 0.18 0
122 7000009390 1990 610 30 Lattice Structure 100001646 995455 Confirmed 18% Confirmed Erection of Std 765 kV Beam BB including nuts, bolts, all type of washers, packplates, step bolts and gusset plates excludingfoundation bolts EA 28 Included 0.00 0 0.18 0
123 7000009390 1990 610 40 Lattice Structure 100001641 995455 Confirmed 18% Confirmed Erection of Std 765 kV Tower CB including nuts, bolts, all type of washers, packplates, step bolts and gusset plates excludingfoundation bolts EA 48 Included 0.00 0 0.18 0
124 7000009390 1990 610 50 Lattice Structure 100001647 995455 Confirmed 18% Confirmed Erection of Std 765 kV Beam BC including nuts, bolts, all type of washers, packplates, step bolts and gusset plates excludingfoundation bolts EA 24 Included 0.00 0 0.18 0
125 7000009390 1990 610 60 Lattice Structure 100001648 995455 Confirmed 18% Confirmed Erection of Std 765 kV Beam BD including nuts, bolts, all type of washers, packplates, step bolts and gusset plates excludingfoundation bolts EA 48 Included 0.00 0 0.18 0
126 7000009390 1990 610 70 Lattice Structure 100001655 995455 Confirmed 18% Confirmed Erection of Std 765 kV Arm GWCB including nuts, bolts, all type of washers, packplates, step bolts and gusset plates excludingfoundation bolts EA 48 Included 0.00 0 0.18 0
127 7000009390 1990 610 80 Lattice Structure 100001642 995455 Confirmed 18% Confirmed Erection of Std 765 kV Tower CC including nuts, bolts, all type of washers, packplates, step bolts and gusset plates excludingfoundation bolts EA 16 Included 0.00 0 0.18 0
128 7000009390 1990 610 90 Lattice Structure 100001649 995455 Confirmed 18% Confirmed Erection of Std 765 kV Beam BE including nuts, bolts, all type of washers, packplates, step bolts and gusset plates excludingfoundation bolts EA 8 Included 0.00 0 0.18 0
129 7000009390 1990 610 100 Lattice Structure 100001650 995455 Confirmed 18% Confirmed Erection of Std 765 kV Beam BF including nuts, bolts, all type of washers, packplates, step bolts and gusset plates excludingfoundation bolts EA 16 Included 0.00 0 0.18 0
130 7000009390 1990 610 110 Lattice Structure 100001656 995455 Confirmed 18% Confirmed Erection of Std 765 kV Arm GWCC including nuts, bolts, all type of washers, packplates, step bolts and gusset plates excludingfoundation bolts EA 16 Included 0.00 0 0.18 0
131 7000009390 1990 610 120 Lattice Structure 100001153 995455 Confirmed 18% Confirmed Erection of Std 400 kV Tower TC including nuts, bolts, all type of washers, packplates, step bolts and gusset plates excludingfoundation bolts EA 6 Included 0.00 0 0.18 0
132 7000009390 1990 610 130 Lattice Structure 100001158 995455 Confirmed 18% Confirmed Erection of Std 400 kV Tower TH including nuts, bolts, all type of washers, packplates, step bolts and gusset plates excludingfoundation bolts EA 4 Included 0.00 0 0.18 0
133 7000009390 1990 610 140 Lattice Structure 100001160 995455 Confirmed 18% Confirmed Erection of Std 400 kV Tower TJ including nuts, bolts, all type of washers, packplates, step bolts and gusset plates excludingfoundation bolts EA 10 Included 0.00 0 0.18 0
134 7000009390 1990 610 150 Lattice Structure 100001164 995455 Confirmed 18% Confirmed Erection of Std 400 kV Tower TN including nuts, bolts, all type of washers, packplates, step bolts and gusset plates excludingfoundation bolts EA 6 Included 0.00 0 0.18 0
135 7000009390 1990 610 160 Lattice Structure 100001171 995455 Confirmed 18% Confirmed Erection of Std 400 kV Gantry G1 including nuts, bolts, all type of washers, packplates, step bolts and gusset plates excludingfoundation bolts EA 8 Included 0.00 0 0.18 0
136 7000009390 1990 610 170 Lattice Structure 100001172 995455 Confirmed 18% Confirmed Erection of Std 400 kV Gantry G2 including nuts, bolts, all type of washers, packplates, step bolts and gusset plates excludingfoundation bolts EA 14 Included 0.00 0 0.18 0
137 7000009390 1990 610 180 Lattice Structure 100001660 995455 Confirmed 18% Confirmed Erection of Std 765 kV Support Structure 1-Phase CT including nuts, bolts, all type of washers, packplates, step bolts and gussetplates excluding foundation bolts EA 42 Included 0.00 0 0.18 0
138 7000009390 1990 610 190 Lattice Structure 100001661 995455 Confirmed 18% Confirmed Erection of Std 765 kV Support Structure 1-Phase CVT including nuts, bolts, all type of washers, packplates, step bolts and gussetplates excluding foundation bolts EA 18 Included 0.00 0 0.18 0
139 7000009390 1990 610 200 Lattice Structure 100001662 995455 Confirmed 18% Confirmed Erection of Std 765 kV Support Structure 3 Phase ISOLATOR including nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts EA 36 Included 0.00 0 0.18 0
140 7000009390 1990 610 210 Lattice Structure 100002573 995455 Confirmed 18% Confirmed Erection of Std 765 kV Support Structure 1 Phase ISOLATOR including nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts EA 72 Included 0.00 0 0.18 0
141 7000009390 1990 610 230 Lattice Structure 100001663 995455 Confirmed 18% Confirmed Erection of Std 765 kV Support Structure 1-Phase LA including nuts, bolts, all type of washers, packplates, step bolts and gussetplates excluding foundation bolts EA 39 Included 0.00 0 0.18 0
142 7000009390 1990 610 240 Lattice Structure 100001659 995455 Confirmed 18% Confirmed Erection of Std 765 kV Support Structure 1-Phase BPI including nuts, bolts, all type of washers, packplates, step bolts and gussetplates excluding foundation bolts EA 90 Included 0.00 0 0.18 0
143 7000009390 1990 610 250 Lattice Structure 100001672 995455 Confirmed 18% Confirmed Erection of 33kV ouble Pole Structure including nuts, bolts, all type of washers, packplates, step bolts and gusset plates excludingfoundation bolts EA 1 Included 0.00 0 0.18 0
144 7000009390 2000 620 10 Pipe Structure 100001212 995455 Confirmed 18% Confirmed Erection of Pipe Structure - 400 kV 1-Phase CT including nuts, bolts, all type of washers, packplates, step bolts and gusset platesexcluding foundation bolts EA 24 Included 0.00 0 0.18 0
145 7000009390 2000 620 20 Pipe Structure 100001213 995455 Confirmed 18% Confirmed Erection of Pipe Structure - 400 kV 1-Phase CVT including nuts, bolts, all type of washers, packplates, step bolts and gusset platesexcluding foundation bolts EA 12 Included 0.00 0 0.18 0
146 7000009390 2000 620 30 Pipe Structure 100001214 995455 Confirmed 18% Confirmed Erection of Pipe Structure - 400 kV 3-Phase ISOLATOR including nuts, bolts, all type of washers, packplates, step bolts and gussetplates excluding foundation bolts EA 20 Included 0.00 0 0.18 0
147 7000009390 2000 620 50 Pipe Structure 100001216 995455 Confirmed 18% Confirmed Erection of Pipe Structure - 400 kV 1-Phase SA including nuts, bolts, all type of washers, packplates, step bolts and gusset platesexcluding foundation bolts EA 16 Included 0.00 0 0.18 0
148 7000009390 2000 620 60 Pipe Structure 100001217 995455 Confirmed 18% Confirmed Erection of Pipe Structure - 400 kV, 1-Phase, BPI, (Excluding Wave Trap), including nuts, bolts, all type of washers,packplates, step bolts and gusset plates excluding foundation bolts EA 30 Included 0.00 0 0.18 0
149 7000009390 2000 620 70 Pipe Structure 100001235 995455 Confirmed 18% Confirmed Erection of Std 66 kV Support Structure 1-Phase CT including nuts, bolts, all type of washers, packplates, step bolts and gussetplates excluding foundation bolts EA 3 Included 0.00 0 0.18 0
150 7000009390 2000 620 80 Pipe Structure 100001236 995455 Confirmed 18% Confirmed Erection of Std 66 kV Support Structure 1-Phase CVT including nuts, bolts, all type of washers, packplates, step bolts and gussetplates excluding foundation bolts EA 3 Included 0.00 0 0.18 0
151 7000009390 2000 620 90 Pipe Structure 100001237 995455 Confirmed 18% Confirmed Erection of Std 66 kV Support Structure 3-Phase ISOLATOR including nuts, bolts, all type of washers, packplates, step bolts andgusset plates excluding foundation bolts EA 2 Included 0.00 0 0.18 0
152 7000009390 2000 620 69 Pipe Structure 100001218 995455 Confirmed 18% Confirmed Erection of Pipe Structure - 400 kV, 1-Phase, High BPI, (Excluding Wave Trap), including nuts, bolts, all type of washers,packplates, step bolts and gusset plates excluding foundation bolts EA 30 Included 0.00 0 0.18 0
153 7000009390 2000 620 170 Pipe Structure 100002589 995455 Confirmed 18% Confirmed Erection of Pipe Structure - 400 kV 1 - PH ISOLATOR including nuts, bolts, all type of washers, packplates, step bolts and gussetplates excluding foundation bolts EA 12 Included 0.00 0 0.18 0
154 7000009390 2000 620 180 Pipe Structure 100001621 995455 Confirmed 18% Confirmed Erection of Std 66 kV Support Structure BPI including nuts, bolts, all type of washers, packplates, step bolts and gusset platesexcluding foundation bolts EA 6 Included 0.00 0 0.18 0
155 7000009390 2010 630 10 Erection Hardware 100000184 998731 Confirmed 18% Confirmed Erection Hardware for 765kV I type layout-Line bay as per specification SET 4 Included 0.00 0 0.18 0
156 7000009390 2010 630 20 Erection Hardware 100000185 998731 Confirmed 18% Confirmed Erection Hardware for 765kV I type layout-Transformer bay as per specification SET 2 Included 0.00 0 0.18 0
157 7000009390 2010 630 30 Erection Hardware 100000186 998731 Confirmed 18% Confirmed Erection Hardware for 765kV I type layout-Bus Reactor bay as per specification SET 2 Included 0.00 0 0.18 0
158 7000009390 2010 630 40 Erection Hardware 100000190 998731 Confirmed 18% Confirmed Erection Hardware for 765kV I type layout-Spare bay of half dia. as per specification SET 2 Included 0.00 0 0.18 0
159 7000009390 2010 630 50 Erection Hardware 100002019 998731 Confirmed 18% Confirmed Erection Hardware for 765kV I type layout-Line Reactors including NGR bypassing arrangement as per technical specification SET 4 Included 0.00 0 0.18 0
160 7000009390 2010 630 60 Erection Hardware 100000331 998731 Confirmed 18% Confirmed Erection Hardware for 400kV I type layout-Bus Reactor bay as per specification as per specification SET 1 Included 0.00 0 0.18 0
161 7000009390 2010 630 70 Erection Hardware 100000335 998731 Confirmed 18% Confirmed Erection Hardware for 400kV I type layout-Spare bay of half dia as per specification SET 1 Included 0.00 0 0.18 0
162 7000009390 2010 630 80 Erection Hardware 100000337 998731 Confirmed 18% Confirmed Erection Hardware for 400kV I type layout-Bus Work (For two diameters)/bays as per specification SET 2 Included 0.00 0 0.18 0
163 7000009390 2010 630 90 Erection Hardware 100002454 998731 Confirmed 18% Confirmed Erection Hardware for the 72.5kV and 36kV equipment (scheme as per SLD) SET 1 Included 0.00 0 0.18 0
164 7000009390 2010 630 110 Erection Hardware 100000329 998731 Confirmed 18% Confirmed Erection Hardware for 400kV I type layout-Line bay as per specification SET 2 Included 0.00 0 0.18 0
165 7000009390 2010 630 120 Erection Hardware 100002305 998731 Confirmed 18% Confirmed Erection Hardware for 400kV I type layout-Transformer bay as per technical specification(including its Tertiary Loading arrangement) SET 2 Included 0.00 0 0.18 0
166 7000009390 2010 630 130 Erection Hardware 100000192 998731 Confirmed 18% Confirmed Erection Hardware for 765kV I type layout-Bus Work (For one diameters) as per specification SET 6 Included 0.00 0 0.18 0
167 7000009390 2020 640 10 145kV Equipment 100001986 998736 Confirmed 18% Confirmed 145kV, 1250A, 31.5KA Circuit Breakers(1-Phase) with support structure EA 4 Included 0.00 0 0.18 0
168 7000009390 2040 660 10 Civil Works 100001324 995433 Confirmed 18% Confirmed Excavation in all types of soil and rock including backfilling disposal etc. for all leads and lifts M3 104238 Included 0.00 0 0.18 0
169 7000009390 2040 660 20 Civil Works 100001325 995454 Confirmed 18% Confirmed Providing and laying of Plain Cement Concrete (PCC) (1:4:8) M3 7085 Included 0.00 0 0.18 0
170 7000009390 2040 660 30 Civil Works 100001326 995454 Confirmed 18% Confirmed Providing and laying of Plain Cement Concrete (PCC) (1:2:4) M3 712 Included 0.00 0 0.18 0
171 7000009390 2040 660 40 Civil Works 100001261 995454 Confirmed 18% Confirmed Concreting (including all associated works related to foundation not covered in excavation and reinforcemt steel works : LeanConcrete (1:3:6) M3 14 Included 0.00 0 0.18 0
172 7000009390 2040 660 50 Civil Works 100001327 995454 Confirmed 18% Confirmed Providing and laying of Reinforced Cement Concrete M25 mix including pre cast, shuttering, Grouting of pockets & underpinning butexcluding steel reinforcement M3 25782 Included 0.00 0 0.18 0
173 7000009390 2040 660 60 Civil Works 100001328 995454 Confirmed 18% Confirmed Providing and laying Plain Cement Concrete 1:5:10 (1 cement : 5 sand : 10 brick aggregate) M3 14175 Included 0.00 0 0.18 0
174 7000009390 2040 660 70 Civil Works 100001329 995454 Confirmed 18% Confirmed Steel Reinforcement MT 1879 Included 0.00 0 0.18 0
175 7000009390 2040 660 80 Civil Works 100001330 995428 Confirmed 18% Confirmed Stone filling (40 mm size) for transformer/Reactor foundation M3 434 Included 0.00 0 0.18 0
176 7000009390 2040 660 90 Civil Works 100001331 995455 Confirmed 18% Confirmed Misc. Structural steel including rails, embedments, edge protection angles, gratings etc. but excluding the reinforcement steel andsteel for lattice and pipe structures. MT 278 Included 0.00 0 0.18 0
177 7000009390 2040 660 100 Civil Works 100001714 995428 Confirmed 18% Confirmed Stone spreading in switchyard excluding PCC M2 270000 Included 0.00 0 0.18 0
178 7000009390 2040 660 110 Civil Works 100001713 995424 Confirmed 18% Confirmed Antiweed treatment M2 270000 Included 0.00 0 0.18 0
179 7000009390 2040 660 120 Civil Works 100003114 995454 Confirmed 18% Confirmed External finishing / painting of fire wall (water proofing cement paint) (DSR 13.44.1) M2 5550 Included 0.00 0 0.18 0
180 7000009390 2040 660 130 Civil Works 100004507 995421 Confirmed 18% Confirmed 3.75m wide Cement Concrete road with PCC shoulder including 100 mm dia RCC Hume Pipe @ 100 metre interval as per drawing and TS.However, reinforcement steel and all type concrete shall be paid separately under relevant items M2 15000 Included 0.00 0 0.18 0
181 7000009390 2040 660 140 Civil Works 100004509 995421 Confirmed 18% Confirmed 5.5m wide Cement Concrete road with PCC shoulder including 100 mm dia RCC Hume Pipe @ 100 metre interval as per drawing and TS.However, reinforcement steel and and all type concrete shall be paid separately under relevant items M2 5500 Included 0.00 0 0.18 0
182 7000009390 2040 660 150 Civil Works 100004508 995421 Confirmed 18% Confirmed 3.75m wide Cement Concrete road with paver block including 100 mm dia RCC Hume Pipe @ 100 metre interval as per drawing and TS.However, reinforcement steel and and all type concrete shall be paid separately under relevant items M2 1875 Included 0.00 0 0.18 0
183 7000009390 2040 660 160 Civil Works 100004510 995421 Confirmed 18% Confirmed 5.5m wide Cement Concrete road with paver block including 100 mm dia RCC Hume Pipe @ 100 metre interval as per drawing and TS.However, reinforcement steel and and all type concrete shall be paid separately under relevant items M2 2750 Included 0.00 0 0.18 0
184 7000009390 2040 660 170 Civil Works 100001718 995421 Confirmed 18% Confirmed Providing and laying 60mm thick factory made cement concrete interlocking paver block of approved size, design & shape, laid inrequired colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc allcomplete as per the direction of engineer in charge. M2 3100 Included 0.00 0 0.18 0
185 7000009390 2040 660 180 Civil Works 100001457 995421 Confirmed 18% Confirmed Construction of rail cum road as per drawing including all item such as excavation,compactions, rolling watering, WBM etc. butexcluding concrete reinforcement and structural steel-Section having four rails for auto transformer. M2 677 Included 0.00 0 0.18 0
186 7000009390 2040 660 190 Civil Works 100001458 995421 Confirmed 18% Confirmed Construction of rail cum road as per drawing including all item such as excavation,compactions, rolling watering, WBM etc. butexcluding concrete reinforcement and structural steel-Section having two rails for Reactor. M2 1350 Included 0.00 0 0.18 0
187 7000009390 2040 660 200 Civil Works 100001391 995477 Confirmed 18% Confirmed New chain Link Fencing excluding concrete M 1500 Included 0.00 0 0.18 0
188 7000009390 2040 660 210 Civil Works 100001392 995455 Confirmed 18% Confirmed Switchyard Gate excluding Concrete EA 6 Included 0.00 0 0.18 0
189 7000009390 2040 660 220 Civil Works 130000761 995428 Confirmed 18% Confirmed 14.4.2 Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointingwith cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. : 150 mm dia M 280 Included 0.00 0 0.18 0
190 7000009390 2040 660 230 Civil Works 130000762 995428 Confirmed 18% Confirmed 14.4.3 Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointingwith cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. : 250 mm dia M 1108 Included 0.00 0 0.18 0
191 7000009390 2040 660 240 Civil Works 100001735 995462 Confirmed 18% Confirmed RCC culverts and cable trench crossings including supplying and laying hume pipe 250mm dia of grade (NP-3) excluding concrete as perspecification. M 640 Included 0.00 0 0.18 0
192 7000009390 2040 660 250 Civil Works 100001736 995462 Confirmed 18% Confirmed RCC culverts and cable trench crossings including supplying and laying hume pipe 300mm dia of grade (NP-3) excluding concrete as perspecification. M 192 Included 0.00 0 0.18 0
193 7000009390 2040 660 260 Civil Works 100001737 995462 Confirmed 18% Confirmed RCC culverts and cable trench crossings including supplying and laying hume pipe 450mm dia of grade (NP-3) excluding concrete as perspecification. M 320 Included 0.00 0 0.18 0
194 7000009390 2040 660 280 Civil Works 100001411 995462 Confirmed 18% Confirmed Supplying and erecting dewatering pumps-0.5 HP EA 2 Included 0.00 0 0.18 0
195 7000009390 2040 660 290 Civil Works 100001412 995462 Confirmed 18% Confirmed Drain including culverts but excluding concrete & reinforcement steel-Section A-A M 7200 Included 0.00 0 0.18 0
196 7000009390 2040 660 300 Civil Works 100001413 995462 Confirmed 18% Confirmed Drain including culverts but excluding concrete & reinforcement steel-Section B-B M 1800 Included 0.00 0 0.18 0
197 7000009390 2040 660 310 Civil Works 100001414 995462 Confirmed 18% Confirmed Drain including culverts but excluding concrete & reinforcement steel-Section C-C M 1800 Included 0.00 0 0.18 0
198 7000009390 2040 660 320 Civil Works 100001415 995462 Confirmed 18% Confirmed Drain including culverts but excluding concrete & reinforcement steel-Section D-D M 1200 Included 0.00 0 0.18 0
199 7000009390 2040 660 330 Civil Works 100001682 995416 Confirmed 18% Confirmed FFPH Building - Civil Works All civil works as per drawing and specifications complete, including - brickwork,finishing (externaland internal),windows etc.However, excavation, PCC,RCC and reinforcement shall be paid separately as per BPS M2 101 Included 0.00 0 0.18 0
200 7000009390 2040 660 340 Civil Works 100001684 995411 Confirmed 18% Confirmed Transit Camp - Civil WorksAll civilworks as per drawing and specificationscomplete, including - brickwork,finishing (external and internal),windows etc.However, excavation, PCC,RCC and reinforcement shall be paidseparately as per BPS. M2 500 Included 0.00 0 0.18 0
201 7000009390 2040 660 350 Civil Works 100001698 995454 Confirmed 18% Confirmed Car Parking (10 cars) - Civil Works.All civil works as per drawing and specifications complete, including - brickwork, finishing(external and internal), windows etc. However,excavation, PCC, RCC and reinforcement shall be paid separately as per BPS. M2 150 Included 0.00 0 0.18 0
202 7000009390 2040 660 360 Civil Works 100001700 995454 Confirmed 18% Confirmed All civil works as per drawing and specification but excluding excavation, PCC, RCC, reinforcement but including finishing (internaland external) etc & all civil works complete in all respect - Water Tank for Fire Fighting Pump House EA 1 Included 0.00 0 0.18 0
203 7000009390 2040 660 370 Civil Works 100001701 995411 Confirmed 18% Confirmed Security Hut - Civil WorksAll civilworks as per drawing and specificationscomplete, including - brickwork,finishing (external and internal),windows etc.However, excavation, PCC,RCC and reinforcement shall be paidseparately as per BPS. M2 18 Included 0.00 0 0.18 0
204 7000009390 2040 660 380 Civil Works 100001722 995462 Confirmed 18% Confirmed Supplying and laying GI pipe for external water supply system - 80 mm dia pipe M 240 Included 0.00 0 0.18 0
205 7000009390 2040 660 390 Civil Works 100001723 995462 Confirmed 18% Confirmed Supplying and laying GI pipe for external water supply system - 50 mm dia pipe M 50 Included 0.00 0 0.18 0
206 7000009390 2040 660 400 Civil Works 100001724 995462 Confirmed 18% Confirmed Supplying and laying GI pipe for external water supply system - 40 mm dia pipe M 50 Included 0.00 0 0.18 0
207 7000009390 2040 660 410 Civil Works 100001725 995462 Confirmed 18% Confirmed Supplying and laying GI pipe for external water supply system - 25 mm dia pipe M 60 Included 0.00 0 0.18 0
208 7000009390 2040 660 420 Civil Works 100003477 995454 Confirmed 18% Confirmed Rain water harvesting excluding reinforcement and concrete as per drawing EA 4 Included 0.00 0 0.18 0
209 7000009390 2040 660 430 Civil Works 100001739 995462 Confirmed 18% Confirmed Septic tank and soakpit for township EA 1 Included 0.00 0 0.18 0
210 7000009390 2040 660 440 Civil Works 100001740 995441 Confirmed 18% Confirmed Septic tank and soakpit for CRB EA 1 Included 0.00 0 0.18 0
211 7000009390 2040 660 450 Civil Works 100002488 995462 Confirmed 18% Confirmed Septic tank and soakpit for Security Room EA 1 Included 0.00 0 0.18 0
212 7000009390 2040 660 460 Civil Works 100001755 995424 Confirmed 18% Confirmed Providing & Laying of SW pipes for external sewerage system as per technical specification 100mm dia pipe M 50 Included 0.00 0 0.18 0
213 7000009390 2040 660 470 Civil Works 100001756 995424 Confirmed 18% Confirmed Providing & Laying of SW pipes for external sewerage system as per technical specification 150mm dia pipe M 20 Included 0.00 0 0.18 0
214 7000009390 2040 660 480 Civil Works 100001757 995424 Confirmed 18% Confirmed Providing & Laying of SW pipes for external sewerage system as per technical specification 200mm dia pipe M 20 Included 0.00 0 0.18 0
215 7000009390 2040 660 490 Civil Works 100002361 995455 Confirmed 18% Confirmed Main Gate EA 1 Included 0.00 0 0.18 0
216 7000009390 2040 660 500 Civil Works 100004812 995454 Confirmed 18% Confirmed Providing & Erecting Boundary Wall as per drawing including excavation, PCC, RCC, reinforcement etc complete as per drawing in allrespect M 3420 Included 0.00 0 0.18 0
217 7000009390 2040 660 510 Civil Works 100003437 995454 Confirmed 18% Confirmed Switchyard Panel Room - Civil Works. All civil works as per drawing and specifications complete, including - brickwork, finishing(external and internal), windows etc. However, excavation, PCC, RCC and reinforcement shall be paid separately as per BPS. M2 350 Included 0.00 0 0.18 0
218 7000009390 2040 660 520 Civil Works 100001683 995414 Confirmed 18% Confirmed Control Room Building - Civil Works All civil works as per drawing and specifications complete, including - brickwork, finishing(external and internal), windows etc. However, excavation, PCC, RCC and reinforcement shall be paid separately as per BPS. M2 750 Included 0.00 0 0.18 0
219 7000009390 2040 660 530 Civil Works 100003652 995432 Confirmed 18% Confirmed Soil Investigation: As per technical specification including all laboratory and field tests, report and recommendations forBoreholes LOT 1 Included 0.00 0 0.18 0
220 7000009390 2040 660 540 Civil Works 100003653 995432 Confirmed 18% Confirmed Soil Investigation: As per technical specification including all laboratory and field tests, report and recommendations for TrialPits LOT 1 Included 0.00 0 0.18 0
221 7000009390 2040 660 550 Civil Works 100003654 995432 Confirmed 18% Confirmed Soil Investigation: As per technical specification including all laboratory and field tests, report and recommendations for PlateLoad Tests LOT 1 Included 0.00 0 0.18 0
222 7000009390 2040 660 560 Civil Works 100003655 995432 Confirmed 18% Confirmed Soil Investigation: As per technical specification including all laboratory and field tests, report and recommendations for CBRLaboratory Tests LOT 1 Included 0.00 0 0.18 0
223 7000009390 2040 660 570 Civil Works 100003656 995432 Confirmed 18% Confirmed Soil Investigation: As per technical specification including all laboratory and field tests, report and recommendations for EarthResistivity Tests LOT 1 Included 0.00 0 0.18 0
224 7000009390 2040 660 680 Civil Works 100002911 995432 Confirmed 18% Confirmed Earthwork in excavation & filling in all types of soil and soft/disintegrated rock in open areas/nallas/channels, to the requiredslopes, shapes, levels, elevations and profile, including trimming of bottom and slopes of excavation, bailing out rain(dewatering), pumping, removal of slush, preparing embankments/marginal banks, loosening, dressing, spreading material in layers notexceeding 200mm, as per direction of Engineer-in-Charge, water flooding, compacting to achieve 95% consolidation at optimum moisturecontent, finishing etc. all complete, for all leads and lifts within leveling boundary, including disposal of surplus earth andstacking of unsuitable material within a lead of 2.0 Km beyond substation boundary, with all labour, material, tools, tackles andequipment, safeguards and incidentals, Royalty,taxes etc. as necessary, as per drawings, specification and directions of theEngineer-in-Charge. Clearing of jungle is included in this item. (Only excavation/cutting will be measured for payment purpose.) M3 239250 Included 0.00 0 0.18 0
225 7000009390 2040 660 690 Civil Works 100002583 995432 Confirmed 18% Confirmed Supply of earth (excluding rock & boulders) at site including royalty, carriage and filling in specified areas in layers notexceeding 200mm in depth, compacting under optimum moisture condition to achieve 95% of Proctor density, finishing etc. allcomplete, for all leads & lifts, with all labour, material, tools, tackles, equipments, safeguards & incidentals as necessary as perdrawings, specification and direction of the Engineer- in- Charge. M3 30000 Included 0.00 0 0.18 0
226 7000009390 2040 660 269 Civil Works 100001409 995462 Confirmed 18% Confirmed Supplying and erecting dewatering pumps-5 HP EA 3 Included 0.00 0 0.18 0
227 7000009390 2050 670 640 Non Standard Structure 100001210 995455 Confirmed 18% Confirmed Erection of Lattice Structures (MS Steel), to be designed during detailed engineering, for towers, beams and equipment supportstructure including pack plates / packwashers and gusset plates excluding fasteners and foundation bolts MT 17 Included 0.00 0 0.18 0
228 7000009390 2050 670 650 Non Standard Structure 100001241 995455 Confirmed 18% Confirmed Erection of Equipment Support (Pipe) Structures to be designed during detailed engineering. MT 15.2 Included 0.00 0 0.18 0
229 7000009390 2050 670 660 Non Standard Structure 100001680 995455 Confirmed 18% Confirmed Erection of fasteners ( nuts, bolts and washers ) including step bolts for lattice and pipe structures to be designed duringdetailed engineering MT 1 Included 0.00 0 0.18 0
230 7000009390 2050 670 670 Non Standard Structure 100001681 995455 Confirmed 18% Confirmed Erection of foundation bolts including nuts, checknut and washers for lattice and pipe structures to be designed during detailedengineering MT 2.7 Included 0.00 0 0.18 0
231 7000009390 2100 690 590 Foundation Bolts 100001674 995455 Confirmed 18% Confirmed Erection of 28mm dia foundation bolts including nuts, checknuts, washers and packplates. EA 1060 Included 0.00 0 0.18 0
232 7000009390 2100 690 600 Foundation Bolts 100001675 995455 Confirmed 18% Confirmed Erection of 32mm dia foundation bolts including nuts, checknuts, washers and packplates EA 6348 Included 0.00 0 0.18 0
233 7000009390 2100 690 620 Foundation Bolts 100001677 995455 Confirmed 18% Confirmed Erection of 56mm dia foundation bolts including nuts, checknuts, washers and packplates EA 768 Included 0.00 0 0.18 0
234 7000009390 2100 690 630 Foundation Bolts 100001679 995455 Confirmed 18% Confirmed Erection of 80mm dia foundation bolts including nuts, checknuts, washers and packplates EA 1024 Included 0.00 0 0.18 0
235 7000009390 2190 720 10 765kV pmu and associated equip. service 170000502 998713 Confirmed 18% Confirmed Service:- Phasor Measurement Unit (PMU) EA 4 Included 0.00 0 0.18 0
236 7000009390 2190 720 20 765kV pmu and associated equip. service 170000530 998734 Confirmed 18% Confirmed WAMS TIME SYSTEM(GPS RECEIVER) EA 4 Included 0.00 0 0.18 0
237 7000009390 2190 720 30 765kV pmu and associated equip. service 170000503 998713 Confirmed 18% Confirmed Installation of Substation Grade Layer-3 LAN Switches as per Technical Specification EA 5 Included 0.00 0 0.18 0
238 7000009390 2190 720 40 765kV pmu and associated equip. service 170000504 998713 Confirmed 18% Confirmed Services:- Armored Fibre Optic Cable and associated termination equipment LOT 1 Included 0.00 0 0.18 0
239 7000009390 2190 720 50 765kV pmu and associated equip. service 170000501 998734 Confirmed 18% Confirmed Integration of PMU with the PDC (Phasor Data Concentrator) of RLDCs and respective SLDCs as required. LOT 1 Included 0.00 0 0.18 0
240 7000009390 2240 740 10 400 kV PMU and associated equip services 170000502 998713 Confirmed 18% Confirmed Service:- Phasor Measurement Unit (PMU) EA 2 Included 0.00 0 0.18 0
241 7000009390 2240 740 20 400 kV PMU and associated equip services 170000530 998734 Confirmed 18% Confirmed WAMS TIME SYSTEM(GPS RECEIVER) EA 2 Included 0.00 0 0.18 0
242 7000009390 2240 740 30 400 kV PMU and associated equip services 170000503 998713 Confirmed 18% Confirmed Installation of Substation Grade Layer-3 LAN Switches as per Technical Specification EA 3 Included 0.00 0 0.18 0
243 7000009390 2240 740 40 400 kV PMU and associated equip services 170000504 998713 Confirmed 18% Confirmed Services:- Armored Fibre Optic Cable and associated termination equipment LOT 1 Included 0.00 0 0.18 0
244 7000009390 2240 740 50 400 kV PMU and associated equip services 170000501 998734 Confirmed 18% Confirmed Integration of PMU with the PDC (Phasor Data Concentrator) of RLDCs and respective SLDCs as required. LOT 1 Included 0.00 0 0.18 0
245 7000009390 2550 770 10 Ser tele eqp at Bhadla-2 incl repeater 100002812 998734 Confirmed 18% Confirmed SDH Equipment (STM-16 MADM upto 5 MSP protected directions)-Base Equipment (Common cards, Cross Connect/control cards, optical basecards, power supply cards, power cabling, other hardware and accessories including sub racks, patch cord, DDF etc fully equipedexcluding optical interface & Tributary cards EA 2 Included 0.00 0 0.18 0
246 7000009390 2550 770 30 Ser tele eqp at Bhadla-2 incl repeater 170000372 998734 Confirmed 18% Confirmed SDH Equipment (STM-16 MADM upto 3 MSP protected directions)-Base Equipment (Common cards, Cross Connect/control cards, optical basecards, power supply cards, power cabling, other hardware and accessories including sub racks, patch cord, DDF etc fully equipedexcluding optical interface & Tributary cards EA 1 Included 0.00 0 0.18 0
247 7000009390 2550 770 50 Ser tele eqp at Bhadla-2 incl repeater 170000433 998734 Confirmed 18% Confirmed Optical Interface Cards/SFP# -S16.1 for SDH Equipment-STM-16 EA 4 Included 0.00 0 0.18 0
248 7000009390 2550 770 60 Ser tele eqp at Bhadla-2 incl repeater 170000435 998734 Confirmed 18% Confirmed Optical Interface Cards/SFP# -L16.2 for SDH Equipment-STM-16 EA 2 Included 0.00 0 0.18 0
249 7000009390 2550 770 90 Ser tele eqp at Bhadla-2 incl repeater 170000374 998734 Confirmed 18% Confirmed Optical Interface Card (to support minimum 150 kms) for STM-16 EA 2 Included 0.00 0 0.18 0
250 7000009390 2550 770 100 Ser tele eqp at Bhadla-2 incl repeater 100003449 998734 Confirmed 18% Confirmed Optical Interface Card (to support minimum 175 kms) for STM-16 EA 2 Included 0.00 0 0.18 0
251 7000009390 2550 770 110 Ser tele eqp at Bhadla-2 incl repeater 170000437 998734 Confirmed 18% Confirmed Optical Line Interface Card (to support minimum 200 Kms) for STM-16 EA 4 Included 0.00 0 0.18 0
252 7000009390 2550 770 120 Ser tele eqp at Bhadla-2 incl repeater 100002822 998734 Confirmed 18% Confirmed Optical Interface Card (to support minimum 225 kms) for STM-16 EA 4 Included 0.00 0 0.18 0
253 7000009390 2550 770 150 Ser tele eqp at Bhadla-2 incl repeater 100002825 998734 Confirmed 18% Confirmed Tributary interface- E1 interface (Minimum 16 nos.) SET 4 Included 0.00 0 0.18 0
254 7000009390 2550 770 160 Ser tele eqp at Bhadla-2 incl repeater 170000550 998336 Confirmed 18% Confirmed Ethernet Interface 10/100 Base T with Layer-2 switching (Min 8 Interfaces per card) EA 4 Included 0.00 0 0.18 0
255 7000009390 2550 770 170 Ser tele eqp at Bhadla-2 incl repeater 100002829 998734 Confirmed 18% Confirmed Tributary interface-Gigabit Ethernet Interfaces 10/100 Mbps with Layer -2 Switching (minimum 2 nos.) SET 2 Included 0.00 0 0.18 0
256 7000009390 2550 770 190 Ser tele eqp at Bhadla-2 incl repeater 170000375 998734 Confirmed 18% Confirmed Equipment Cabinets-For SDH Equipments EA 3 Included 0.00 0 0.18 0
257 7000009390 2550 770 220 Ser tele eqp at Bhadla-2 incl repeater 170000376 998734 Confirmed 18% Confirmed NMS-Craft Terminal-Hardware EA 2 Included 0.00 0 0.18 0
258 7000009390 2550 770 230 Ser tele eqp at Bhadla-2 incl repeater 170000377 998734 Confirmed 18% Confirmed NMS-Craft Terminal-Software EA 2 Included 0.00 0 0.18 0
259 7000009390 2550 770 250 Ser tele eqp at Bhadla-2 incl repeater 170000551 998336 Confirmed 18% Confirmed VOIP telephone instrument with one common switch (min. 8 port) EA 8 Included 0.00 0 0.18 0
260 7000009390 2550 770 280 Ser tele eqp at Bhadla-2 incl repeater 100002861 998734 Confirmed 18% Confirmed Repeater Shelter System including all shelter items such as Air-Conditioner, DG Sets, Static Voltage Stabliser, DCPS & Battery etcas per Technical Specification of PUF insulated pre-coated Steel Shelter (Inner dimension : 4340 X 2540 X 3000 mm & Outer dimension4500 X 2700 X 3160 mm) SET 1 Included 0.00 0 0.18 0
261 7000009390 2550 770 51 Ser tele eqp at Bhadla-2 incl repeater 170000434 998734 Confirmed 18% Confirmed Optical Interface Cards/SFP# -L16.1 for SDH Equipment-STM-16 EA 2 Included 0.00 0 0.18 0
Total Installation Charges 0.00 0
Total GST as confirmed by Bidder 0.00
* In case the bidder leaves the cell for confirmation of the SAC and/or GST rate “blank”, the SAC and corresponding GST rate indicated by the Employer shall be deemed to be the one confirmed by the Bidder.
Place : Printed Name :
CC-CS/912-NR1/SS-3933/3/G10 (SS29) Schedule - 3
AIS Substation Package-SS29 Establishment of 765/400kV Bhadla-II PS (Jodhpur) new S/S under Transmission Scheme for Solar Energy Zones in Rajasthan As per Lum-sum 0.00%
(SCHEDULE OF RATES AND PRICES : ERECTION CHARGES) AS per Percent #REF!
As per lum-sum on Sch-3 0.00%
Bidder’s Name and Address (Lead Partner) : To: As per Percent on Sch-3 #REF!
Contracts Services, 3rd Floor Total Discount #REF!
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Sector-29, Multipackage lum-sum 0.00%
Gurgaon (Haryana) - 122001
All Prices are in Indian Rupees. Amount after Discount (Rs.) Dis Alert Amount after MPD (Rs.)
SI. No. Description Unit Quantity Unit Erection Charges Total Erection Charges Unit Erection Charges Total Erection Charges Unit Erection Charges Total Erection Charges
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! (a) Detailed Soil Investigation
#REF! #REF! #REF! #REF! #REF! (b) All kinds of soil except fissured rock & hard rock
#REF! #REF! #REF! #REF! #REF! (e) River Crossing Location
#REF! #REF! #REF! #REF! #REF! (f)
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
Total Erection Price (A+B) #REF!
Place : Printed Name :
CC-CS/912-NR1/SS-3933/3/G10 (SS29) Schedule - 4
AIS Substation Package-SS29 Establishment of 765/400kV Bhadla-II PS (Jodhpur) new S/S under Transmission Scheme for Solar Energy Zones in Rajasthan
(SCHEDULE OF RATES AND PRICES )
Bidder’s Name and Address (Lead Partner) : To:
Contracts Services, 3rd Floor
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Gurgaon (Haryana) - 122001
Training Charges for Training to be imparted
SI. No. PR No PR Line Item No Activity Header PR Activity No Activity Description Service Code SAC (Service Accounting Codes) Whether SAC in column '8’ is confirmed. If not indicate applicable the SAC * Rate of GST applicable ( in %) Whether rate of GST in column ‘4’ is confirmed. If not indicate applicable rate of GST * Description Unit Quantity Unit Training Charges excluding GST Total Training Charges excluding GST Total GST as confirmed by Bidder
220 KV SS EXT PKG-SS-25-LUCKNOW SS Revaluation of J column Tax Calculation
Revaluation of J column Tax Calculation
1 7000009390 2030 650 10 Training At Site 100003236 998399 Confirmed 18 Confirmed Training at site for Visual Monitoring System MND 1 Included 0.00 0 18 0
2 7000009390 2030 650 20 Training At Site 100002671 998399 Confirmed 18 Confirmed Training at substation site in the area of testing, commissioining, operation and maintenece of Protection and automation system TAG 5 Included 0.00 0 18 0
3 7000009390 2030 650 30 Training At Site 100002670 998399 Confirmed 18 Confirmed Training at substation Site in the area of erection, testing, commissioining, operation and maintenence of CB, Isolator, CT, CVT andSurge Arrester. TAG 3 Included 0.00 0 18 0
4 7000009390 2030 650 40 Training At Site 100001600 998399 Confirmed 18 Confirmed Training at substation site in the area of testing, commissioining operation and maintenece of PLCC System. MND 3 Included 0.00 0 18 0
Total Training Charges 0.00 0
Total GST as confirmed by Bidder 0.00
Date : -- Printed Name :
Place : Designation :
CC-CS/912-NR1/SS-3933/3/G10 (SS29) Schedule - 4b
AIS Substation Package-SS29 Establishment of 765/400kV Bhadla-II PS (Jodhpur) new S/S under Transmission Scheme for Solar Energy Zones in Rajasthan
(SCHEDULE OF RATES AND PRICES )
Bidder’s Name and Address (Lead Partner) : To:
Contracts Services, 3rd Floor
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Gurgaon (Haryana) - 122001
Maintenance Charges during & after Defect Laibility Period
SI. No. PR No PR Line Item No Activity Header PR Activity No Activity Description Service Code SAC (Service Accounting Codes) Whether SAC in column '8’ is confirmed. If not indicate applicable the SAC * Rate of GST applicable ( in %) Whether rate of GST in column ‘4’ is confirmed. If not indicate applicable rate of GST * Description Unit Quantity Unit Maintenance Charges excluding GST Total Maintenance Charges excluding GST Total GST as confirmed by Bidder
0 Revaluation of P column Tax Calculation
A. #REF! Revaluation of P column Tax Calculation
1 Included 0.00 0 0
2 Included 0.00 0 0
3 Included 0.00 0 0
4 Included 0.00 0 0
B. #REF! Revaluation of P column Tax Calculation
1 Included 0.00 0 0
2 Included 0.00 0 0
3 Included 0.00 0 0
4 Included 0.00 0 0
Total Maintenance Charges during and after Defect Liabilty Period 0.00 0
Total GST as confirmed by Bidder 0.00
Date : -- Printed Name :
Place : Designation :
CC-CS/912-NR1/SS-3933/3/G10 (SS29) Schedule - 5
AIS Substation Package-SS29 Establishment of 765/400kV Bhadla-II PS (Jodhpur) new S/S under Transmission Scheme for Solar Energy Zones in Rajasthan
(SUMMARY OF TAXES & DUTIES APPLICABLE ON PLANT & EQUIPMENT)
Bidder’s Name and Address (Lead Partner) : To:
Contracts Services, 3rd Floor
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Gurgaon (Haryana) - 122001
Sl. No. Item Nos. Total Price (INR) After Discount After MPDiscount
1 TOTAL GST ON GOODS Excise Duty #REF! Excise Duty #REF!
Total GST for Supply of Goods (inter-alia including Type Test Charges) between the Contractor and the Employer (identified in Schedule 1') which are not included in the Ex-works price as per the provision of the Bidding Documents, as applicable. 0.00
2 TOTAL GST ON SERVICES Sales Tax 0.00 Sales Tax 0.00
Total GST on Installation Services (Schedule-3), Training to be imparted in India (Schedule-4) 0.00 #REF! 0 #REF! 0
GRAND TOTAL [1+2] 0.00 Grand Total after Discount #REF! Grand Total after MPD #REF!
Date : -- Printed Name :
Place : Designation :
CC-CS/912-NR1/SS-3933/3/G10 (SS29) Schedule - 5
AIS Substation Package-SS29 Establishment of 765/400kV Bhadla-II PS (Jodhpur) new S/S under Transmission Scheme for Solar Energy Zones in Rajasthan
SUMMARY OF TAXES & DUTIES APPLICABLE ON GOODS
Bidder’s Name and Address (Lead Partner) : To:
Contracts Services, 3rd Floor
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Gurgaon (Haryana) - 122001
Sl. No. Item Nos. Total Price (INR)
1 TOTAL GST ON GOODS 0.00
Total GST for Supply of Goods (inter-alia including Type Test Charges) between the Contractor and the Employer (identified in Schedule 1') which are not included in the Ex-works price as per the provision of the Bidding Documents, as applicable.
2 TOTAL GST ON SERVICES 0.00
Total GST on Installation Services (Schedule-3), Training to be imparted in India (Schedule-4a) and Maintenance Charges during and after Defect Liabilty Period (Schedule-4b)
GRAND TOTAL [1+2] 0.00
Date : -- Printed Name :
Place : Designation :
CC-CS/912-NR1/SS-3933/3/G10 (SS29) Schedule - 6
AIS Substation Package-SS29 Establishment of 765/400kV Bhadla-II PS (Jodhpur) new S/S under Transmission Scheme for Solar Energy Zones in Rajasthan
(GRAND SUMMARY)
Bidder’s Name and Address (Lead Partner) : To:
Contracts Services, 3rd Floor
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Gurgaon (Haryana) - 122001
Sl. No. Description Total Price (INR)
1 TOTAL SCHEDULE NO. 1 0.00
Ex-works price of Plant and Equipment including Type Test Charges
2 TOTAL SCHEDULE NO. 2 0.00
Local Transportation, In-transit Insurance, loading & unloading
3 TOTAL SCHEDULE NO. 3 0.00
Installation Charges
4 TOTAL SCHEDULE NO. 4 0.00
Training Charges
4b TOTAL SCHEDULE NO. 4b 0.00
Maintenance Charges during & after Defect Laibility Period
5 TOTAL SCHEDULE NO. 5 0.00
Taxes and Duties
6 TOTAL SCHEDULE NO. 7 0.00
Type Test Charges [Total of this Schedule is included in Schedule - 1 above.]
GRAND TOTAL [1+2+3+4+5] 0.00
Date : -- Printed Name :
Place : Designation :
CC-CS/912-NR1/SS-3933/3/G10 (SS29) Schedule - 6 After Discount
AIS Substation Package-SS29 Establishment of 765/400kV Bhadla-II PS (Jodhpur) new S/S under Transmission Scheme for Solar Energy Zones in Rajasthan
(GRAND SUMMARY)
Bidder’s Name and Address (Lead Partner) : To:
Contracts Services, 3rd Floor
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Gurgaon (Haryana) - 122001
Sl. No. Description Total Price (INR)
1 TOTAL SCHEDULE NO. 1 0.00
Ex-works price of Plant and Equipment including Type Test Charges
2 TOTAL SCHEDULE NO. 2 0.00
Local Transportation, In-transit Insurance, loading & unloading
3 TOTAL SCHEDULE NO. 3 0.00
Installation Charges
4 TOTAL SCHEDULE NO. 4 0.00
Training Charges
4b TOTAL SCHEDULE NO. 4b 0.00
Maintenance Charges during & after Defect Laibility Period
5 TOTAL SCHEDULE NO. 5 0.00
Taxes and Duties
6 TOTAL SCHEDULE NO. 7 0.00
Type Test Charges [Total of this Schedule is included in Schedule - 1 above.]
GRAND TOTAL [1+2+3+4+5] 0.00
Date : -- Printed Name :
Place : Designation :
CC-CS/912-NR1/SS-3933/3/G10 (SS29) Schedule 7
AIS Substation Package-SS29 Establishment of 765/400kV Bhadla-II PS (Jodhpur) new S/S under Transmission Scheme for Solar Energy Zones in Rajasthan As per Lum-sum 0.00%
(SCHEDULE OF RATES AND PRICES ) AS per Percent #REF!
As per lum-sum on Sch-7 0.00%
Bidder’s Name and Address (Lead Partner) : To: As per Percent on Sch-7 #REF!
Contracts Services, 3rd Floor Total Discount #REF!
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Sector-29, Multipackage Discount 0.0000%
Gurgaon (Haryana) - 122001
Type tests on Earthwire, Hardwar Fittings & accessories of conductor & earthwire:
SL. NO. PR No Line Item No Code HSN Code Whether HSN in column ‘2’ is confirmed. If not indicate applicable the HSN code * Rate of GST applicable ( in %) Whether rate of GST in column ‘4’ is confirmed. If not indicate applicable rate of GST * Description of Test Unit Quantity Unit Test Charge Total Test Charges (Rs.) Total GST as confirmed by Bidder Revaluation of M column Tax Calculation Total Test Charges After Discount (Rs.) Dis Alert Total Test Charges After MPD (Rs.)
1 Included 0.00 0 0.00
2 Included 0.00 0 0.00
TOTAL TYPE TEST CHARGES 0.00
Total GST as confirmed by Bidder 0.00
Date : -- Printed Name :
Place : Designation :
Note : Bidder should indicate the name of test laboratories where type tests are proposed to be conducted
CC-CS/912-NR1/SS-3933/3/G10 (SS29)
AIS Substation Package-SS29 Establishment of 765/400kV Bhadla-II PS (Jodhpur) new S/S under Transmission Scheme for Solar Energy Zones in Rajasthan 0 0
(SCHEDULE OF RATES AND PRICES ) 0 0
Bidder’s Name and Address (Lead Partner) :
SL. NO. Description of Test #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
CC-CS/912-NR1/SS-3933/3/G10 (SS29)
AIS Substation Package-SS29 Establishment of 765/400kV Bhadla-II PS (Jodhpur) new S/S under Transmission Scheme for Solar Energy Zones in Rajasthan As per Lum-sum 0.00%
(SCHEDULE OF RATES AND PRICES : TYPE TEST CHARGES) AS per Percent #REF!
As per lum-sum on Sch-7 0.00%
Bidder’s Name and Address (Lead Partner) : To: As per Percent on Sch-7 #REF!
Contracts Services, 3rd Floor Total Discount #REF!
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Sector-29, Multipackage Discount 0.0000%
Gurgaon (Haryana) - 122001
Type Tests on Earthwire
SL. NO. Description of Test Unit Quantity Unit Test Charge Total Test Charges (Rs.) Total Test Charges After Discount (Rs.) Dis Alert Total Test Charges After MPD (Rs.)
(a) #REF! #REF! #REF! #REF! #REF!
(b) #REF! #REF! #REF! #REF! #REF!
Sub-Total (I) #REF!
TOTAL TEST CHARGES (I) #REF!
Discount Sche-7 #REF! MPD Sche-7 #REF!
Dis Alert #REF!
Date : -- Printed Name :
Place : Designation :
Note : Bidder should indicate the name of test laboratories where type tests are proposed to be conducted
CC-CS/912-NR1/SS-3933/3/G10 (SS29)
AIS Substation Package-SS29 Establishment of 765/400kV Bhadla-II PS (Jodhpur) new S/S under Transmission Scheme for Solar Energy Zones in Rajasthan 0 0 0
(SCHEDULE OF RATES AND PRICES : TYPE TEST CHARGES) 0 0 0
Bidder’s Name and Address (Lead Partner) : 0
SL. NO. Description of Test 0
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
This letter of discount is optional. Bidder may / may not offer any discount.
CC-CS/912-NR1/SS-3933/3/G10 (SS29) Letter of Discount
LETTER OF DISCOUNT
Contract Services
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No.-2
Sector-29, (near IFFCO Chowk)
Gurgaon (Haryana) - 122001
Subject : AIS Substation Package-SS29 Establishment of 765/400kV Bhadla-II PS (Jodhpur) new S/S under Transmission Scheme for Solar Energy Zones in Rajasthan
With reference to the subject tender, we hereby offer unconditional discount on the prices quoted by us as per details given here below : Eq Weightage of Rs/ % Final Discount Factor
1 Discount on lum-sum basis on total price quoted by us without Taxes & Duties. [The discount shall be proportionately applicable on all the items of all the Schdules i.e. Sch-1 (without type test charges), Sch-2, Sch-3, Sch-4a, Sch-4b & Sch-7] In Rs. 0.00 0.0000000000%
2 Discount on percent basis on total price quoted by us without Taxes & Duties. [The discount shall be proportionately applicable on all the items of all the Schdules i.e. Sch-1 (without type test charges), Sch-2 , Sch-3, Sch-4a, Sch-4b & Sch-7] In Percent (%) 0.00 0.00%
3 Discount on lum-sum basis on the Schedules as given below : [The discount shall be proportionately applicable on all the relevent items of the respective Schdules.] In Rs.
Schedule-1 : Ex works prices In Rs. 0.00 0.0000000000% Schedule-1 : Ex-Works Price 0.0000000000%
Schedule-2 : Freight & Insurance In Rs. 0.00 0.0000000000% Schedule-2 : Freight & Insurance 0.0000000000%
Schedule-3 : Erection Charges In Rs. 0.00 0.0000000000% Schedule-3 : Erection Charges 0.0000000000%
Schedule-4a : Training Charges In Rs. 0.00 0.0000000000% Schedule-4a : Training Charges 0.0000000000%
Schedule-4b : Maintenance Charges during and after DLP In Rs. 0.00 0.0000000000% Schedule-4b : Maintenance Charges 0.0000000000%
Schedule-7 : Type Test Charges In Rs. 0.00 0.0000000000% Schedule-7 : Type Test Charges 0.0000000000%
4 Discount on percent basis on the Schedules as given below : [The discount shall be proportionately applicable on all the relevent items of the respective Schdules.] In Percent (%)
Schedule-1 : Ex works prices In Percent (%) 0.00 0.00%
Schedule-2 : Freight & Insurance In Percent (%) 0.00 0.00%
Schedule-3 : Erection Charges In Percent (%) 0.00 0.00%
Schedule-4a : Training Charges In Percent (%) 0.00 0.00%
Schedule-4b : Maintenance Charges during and after DLP In Percent (%) 0.00 0.00%
Schedule-7 : Type Test Charges In Percent (%) 0.00 0.00%
Discount(s) offered at sl. No. 1 to 4 will get displayed and accounted for automatically in the respective items of the Schedules.
5 We hereby offer Multi-package discount as given below:
Multi-Package Discount(s) offered at sl. No. 5 will not get automatically accounted for in the respective items of the Schedules. The same shall be worked out saparately for evaluation.
Please consider this letter of discount as the integral part of our price bid.
Thanking you, we remain,
Yours faithfully,
For and on behalf of
Date : -- Printed Name :
Place : Designation :
Details of Octroi
Sl No. Description of Items Amount on which Octroi is applicable Rate of Octroi Octroi
Details of Entry Tax
Sl No. Description of Items Amount on which Entry Tax is applicable Rate of Entry Tax Entry Tax
Details of Other Taxes & Duties
Sl No. Description of Items Amount on which Other Taxes & Duties are applicable Description of Taxes & Duties Rate of Taxes & Duties Amount of Taxes & Duties
CC-CS/912-NR1/SS-3933/3/G10 (SS29) Bid Form 2nd Envelope 0 1 st 1 January
0 2 nd 2 February
BID FORM (Second Envelope) 3 rd 3 March
Bid Proposal Ref. No. 5 th 5 May
Date : -- 6 th #VALUE! 6 June
7 th #VALUE! 7 July
To: 8 th #VALUE! 8 August
Contracts Services, 3rd Floor 9 th #VALUE! 9 September
Power Grid Corporation of India Ltd., 10 th 10 October
"Saudamini", Plot No.-2 11 th 11 November
Sector-29, 12 th 12 December
Gurgaon (Haryana) - 122001 13 th
Name of Contract : AIS Substation Package-SS29 Establishment of 765/400kV Bhadla-II PS (Jodhpur) new S/S under Transmission Scheme for Solar Energy Zones in Rajasthan 15 th
Dear Ladies and/or Gentlemen, 16 th
Schedule 1 Plant and Equipment (Including Mandatory Spare Parts) to be supplied, including Type Test Charges. 21 st
Schedule 2 Local Transportation, In-transit Insurance, loading and unloading 22 th
Schedule 3 Installation Charges. 23 th
Schedule 4 Training charges for training to be imparted. 24 th
Schedule 4b Maintenance Charges during & after Defect Laibility Period.
Schedule 5 Taxes and Duties not included in Schedule 1 25 th
Schedule 6 Grand Summary [Schedule 1to 5] 26 th
Schedule 7 Break-up of Type Test Charges for Type Tests to be conducted 27 th
2.5 We declare that items left blank in the Schedules will be deemed to have been included in other items. The TOTAL for each Schedule and the TOTAL of Grand Summary shall be deemed to be the total price for executing the Facilities and sections thereof in complete accordance with the Contract, whether or not each individual item has been priced. 31 st
3.0 We confirm that except as otherwise specifically provided our Bid Prices in this Second Envelope include all taxes, duties, levies and charges as may be assessed on us/our Associate (applicable for Foreign Bidder), our Sub-Contractor/Sub-Vendor or their employees by all municipal, state or national government authorities in connection with the Facilities, in and outside of India.
3.1 100% of applicable Taxes and Duties i.e GST which are payable by the Employer under the Contract, shall be reimbursed by the Employer on production of satisfactory documentary evidence by the Contractor in accordance with the provisions of the Bidding Documents.
3.3 We confirm that we have also registered/we shall also get registered in the GST Network with a GSTIN, in all the states where the project is located and the states from which we shall make our supply of goods.
4.0 # (For Joint Venture only) We, the partners of Joint Venture submitting this bid, do agree and confirm that in case of Award of Contract on the Joint Venture, we shall be jointly and severally liable and responsible for the execution of the Contract in accordance with Contract terms and conditions. 2
5.0 We, hereby, declare that only the persons or firms interested in this proposal as principals are named here and that no other persons or firms other than those mentioned herein have any interest in this proposal or in the Contract to be entered into, if the award is made on us, that this proposal is made without any connection with any other person, firm or party likewise submitting a proposal is in all respects for and in good faith, without collusion or fraud.
Thanking you, we remain,
Yours faithfully,
For and on behalf of
Date : -- Printed Name :
Place : Designation :
In case of bid from a Joint Venture, name & designation of representative of JV partner is to be provided and Bid Form is also to be signed by him.
Please provide additional information of the Bidder
Business Address :
Country of Incorporation :
State/Province to be indicated :
Name of Principal Officer :
Address of Principal Officer :
Note: Bidders may note that no prescribed proforma has been enclosed for Attachment 2 : Power of Attorney. Bidders may use their own proforma for furnishing the required information with the bid.
STATEMENT OF QUOTED / CORRECTED PRICES
All Figures are in Rupees
Sl. No. Price Component Quoted Price Corrected Price
1 TOTAL SCHEDULE NO. 1:Ex-Works Price of Plant and Equipment including Type Test Charges 0.00 0.00
2 TOTAL SCHEDULE NO.2: Local Transportation, Insurance and other Incidental Services. 0.00 0.00
3 TOTAL SCHEDULE NO.3: Installation Charges 0.00 0.00
4 TOTAL SCHEDULE NO.4: Training Charges Not Applicable Not Applicable
5 TOTAL BID PRICE: (Excluding Taxes & Duties) 0.00 0.00
6 DISCOUNT #REF! #REF! #REF!
7 NET BID PRICE (Excluding Taxes & Duties) #REF! #REF!
8 TAXES & DUTIES PAYABLE ADDITIONALLY
A) EXCISE DUTY 0 0.00
B) CENTRAL SALES TAX 0 0.00
C) VAT #REF! 0.00
D) ENTRY TAX / OCTROI #REF! 0.00
F) TOTAL TAXES & DUTIES #REF! 0.00
8 TOTAL BID PRICE (INCLUDING TAXES & DUTIES) #REF! 0.00
9 TOTAL SCHEDULE NO.7: Type Test Charges [Total of this Schedule is included in Schedule-1 above] 0.00 0.00
I) Bidder has indicated the following taxes and duties additionally applicable for their bid:
Excise Duty % as Excise Duty
#REF! VAT #REF! #REF!
#REF! Entry Tax/ Octroi #REF! #REF!
Others as Others
II) With regard to Entry Tax, it may be mentioned that the substations covered under the subject pacakge falls in State of MP, where an entry tax @ 2% of Purchase Price is applicable. In view of the above, the taxes and duties inter-alia including entry tax applicable for the bids are calculated :
a) Ex-Works Price of Direct Supplies (after discount, if any) Rs. 0
b) Excise Duty, as applicable on (a) above at the rate : 10.00% Rs. 0
c) Amount on which Sales Tax is applicable 0.00 0
d) CST, as applicable on (a) + ED (b) above at the rate : 2.00% Rs. 0
e) VAT, as applicable on (a) + ED (b) above at the rate : 1.00% 0
g) Purchase Price for Entry Tax (Total Ex-Works+F&I+ED+CST+Others) Rs. 0
h) Entry Tax, as applicable on (e) above at the rate : Rs. 0.00
AIS Substation Package-SS29 Establishment of 765/400kV Bhadla-II PS (Jodhpur) new S/S under Transmission Scheme for Solar Energy Zones in Rajasthan Statement of Quoted / Corrected Prices Page
Spec. No. CC-CS/912-NR1/SS-3933/3/G10 (SS29)
STATEMENT OF QUOTED / CORRECTED PRICES
All Figures are in Rupees
Sl. No. Price Component Quoted Price Corrected Price
1 TOTAL SCHEDULE NO. 1:Ex-Works Price of Plant and Equipment including Type Test Charges 0.00 0.00
2 TOTAL SCHEDULE NO.2: Local Transportation, Insurance and other Incidental Services. 0.00 0.00
3 TOTAL SCHEDULE NO.3: Installation Charges 0.00 0.00
4 TOTAL SCHEDULE NO.4: Training Charges Not Applicable Not Applicable
5 TOTAL BID PRICE: (Excluding Taxes & Duties) 0.00 0.00
6 DISCOUNT #REF! #REF!
7 NET BID PRICE (Excluding Taxes & Duties) #REF! #REF!
8 TAXES & DUTIES PAYABLE ADDITIONALLY
A) EXCISE DUTY #REF! 0.00
B) CENTRAL SALES TAX /VAT #REF! #REF!
C) ENTRY TAX / OCTROI #REF! #REF!
D) OTHERS #REF! 0.00
E) TOTAL TAXES & DUTIES #REF! #REF!
8 TOTAL BID PRICE (INCLUDING TAXES & DUTIES) #REF! #REF!
9 TOTAL SCHEDULE NO.7: Type Test Charges [Total of this Schedule is included in Schedule-1 above] 0.00 0.00
I) Bidder has indicated the following taxes and duties additionally applicable for their bid:
a) Excise Duty Rs. #REF!
b) CST /VAT Rs. #REF!
c) Entry Tax / Octroi Rs. #REF!
d) Others Rs. #REF!
II) Bidder has offered following discount(s)
III) With regard to Entry Tax, it may be mentioned that the substations covered under the subject pacakge falls in State of MP, where an entry tax @ 1% of Purchase Price is applicable. In view of the above, the taxes and duties inter-alia including entry tax applicable for the bids are calculated : Details of dicounts
a) Ex-Works Price of Direct Supplies (after discount, if any) Rs. 0 Gross LS #REF! #REF! #REF! Gross % #REF! #REF! #REF!
b) Excise Duty @ 10.3% of (a) above Rs. 0 #REF! #REF!
c) CST / VAT @ 2% of Ex-Works of Direct Supplies (a) + ED (b) above Rs. #REF! Sch-1 Direct LS #REF! #REF! #REF! Sch-1 Direct % #REF! #REF! #REF!
d) Others Rs. Sch-1 BO LS #REF! #REF! #REF! Sch-1 BO % #REF! #REF! #REF!
e) Purchase Price for Entry Tax (Total Ex-Works+F&I+ED+CST+Others) Rs. #REF! Sch-2 LS #REF! #REF! #REF! Sch-2 % #REF! #REF! #REF!
f) Entry Tax @ 1% of (e) above Rs. #REF! Sch-3 LS #REF! #REF! #REF! Sch-3 % #REF! #REF! #REF!
Sch-7 LS #REF! #REF! #REF! Sch-7 % #REF! #REF! #REF!
AIS Substation Package-SS29 Establishment of 765/400kV Bhadla-II PS (Jodhpur) new S/S under Transmission Scheme for Solar Energy Zones in Rajasthan Statement of Quoted / Corrected Prices Page Different Manner #REF!
Text for Discount #REF!
23 Twenty Three
27 Twenty Seven
28 Twenty Eight
33 Thirty Three
37 Thirty Seven
38 Thirty Eight
73 Seventy Three
74 Seventy Four
75 Seventy Five
77 Seventy Seven
78 Seventy Eight
79 Seventy Nine
83 Eighty Three
87 Eighty Seven
88 Eighty Eight
93 Ninety Three
97 Ninety Seven
98 Ninety Eight
100 One Hundred
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html
ELP 765-400kV Bhadla-II.pdf
pdf • 0.89 MB
SLP 765-400kV Bhadla-II.pdf
pdf • 1.00 MB
Standard_AC_DC_SLD_765kVSubstation.pdf
pdf • 0.23 MB
Typical module drawings.pdf
pdf • 0.14 MB
56 dia.pdf
pdf • 0.10 MB
80 MM DIA FDN. BOLT.pdf
pdf • 0.33 MB
foundation bolt 28.pdf
pdf • 0.08 MB
foundation bolt 32.pdf
pdf • 0.16 MB
STD TRANSIT CAMP.pdf
pdf • 2.29 MB
STD.BOLT 20MM DIA.pdf
pdf • 0.05 MB
page-10.pdf
pdf • 1.26 MB
page-11.pdf
pdf • 1.12 MB
page-12.pdf
pdf • 1.25 MB
page-13.pdf
pdf • 1.37 MB
page-14.pdf
pdf • 1.43 MB
page-15.pdf
pdf • 1.02 MB
page-16.pdf
pdf • 1.38 MB
page-9.pdf
pdf • 1.06 MB
page-1.pdf
pdf • 1.05 MB
page-2.pdf
pdf • 1.19 MB
page-3.pdf
pdf • 0.94 MB
page-4.pdf
pdf • 1.21 MB
page-5.pdf
pdf • 1.15 MB
page-6.pdf
pdf • 1.02 MB
page-7.pdf
pdf • 1.01 MB
page-8.pdf
pdf • 1.03 MB
Deluge Valve (TS-10).pdf
pdf • 1.33 MB
STANDARD BOUNDARY WALL_1.pdf
pdf • 0.70 MB
STANDARD BOUNDARY WALL_2.pdf
pdf • 0.39 MB
STANDARD BOUNDARY WALL_3.pdf
pdf • 0.49 MB
STANDARD BOUNDARY WALL_4.pdf
pdf • 0.42 MB
STANDARD BOUNDARY WALL_5.pdf
pdf • 0.35 MB
STANDARD BOUNDARY WALL_6.pdf
pdf • 0.34 MB
STANDARD BOUNDARY WALL_7.pdf
pdf • 0.28 MB
1000 Series Sheet 1000 to 1013 for 765kV SS-1-12.pdf
pdf • 8.41 MB
1000 Series Sheet 1014 to 1022 for 765kV SS-12-12.pdf
pdf • 0.86 MB
4 STD Panel Room (3M).pdf
pdf • 0.63 MB
4 STD Panel Room (6M).pdf
pdf • 0.67 MB
4 STD Panel Room (9M).pdf
pdf • 0.69 MB
4 STD Panel Room (Sheet 3).pdf
pdf • 4.38 MB
Architectural Drawing 10cars parking shed.pdf
pdf • 0.18 MB
C-ENGG-TS-STD-PAR-10-M25-STR-01A.pdf
pdf • 0.56 MB
C-ENGG-TS-STD-PAR-10-M25-STR-02.pdf
pdf • 0.52 MB
Recharge Water Harvesting_2017.pdf
pdf • 0.40 MB
Switchyard Gate (TS-10).pdf
pdf • 1.20 MB
CABLE TRENCH & CROSSING DETAILS.pdf
pdf • 0.63 MB
Drain (TS-10).pdf
pdf • 2.24 MB
Rail Cum Road.pdf
pdf • 1.30 MB
Raod Culvert (TS-10).pdf
pdf • 1.50 MB
RCC Road-TS 10.pdf
pdf • 2.81 MB
Switchyard Chain Link Fencing (TS-10).pdf
pdf • 1.44 MB
474031-400kv 4TJ(SH.1 OF 1).pdf
pdf • 4.02 MB
474035-400kv 4TN(SH.1 OF 1).pdf
pdf • 4.23 MB
Double Pole Structure for LT Yard. sheets 2.pdf
pdf • 0.87 MB
STD EQP 72.5kV 50M Sec.pdf
pdf • 0.65 MB
474021-400kv 4G2(SH.1 OF 2).pdf
pdf • 4.27 MB
474021-400kv 4G2(SH.2 OF 2).pdf
pdf • 3.78 MB
474024-400kv 4TC(SH.1 OF 1).pdf
pdf • 3.72 MB
474029-400kv 4TH(SH.1 OF 1).pdf
pdf • 5.34 MB
474020-400kv 4G1(SH.1 OF 2).pdf
pdf • 4.80 MB
474020-400kv 4G1(SH.2 OF 2).pdf
pdf • 4.03 MB
474016-400kv 4P1(SH.1 OF 1).pdf
pdf • 3.52 MB
474017-400kv 4P2(SH.1 OF 1).pdf
pdf • 4.34 MB
474001-400kv 4BPI(SH.1 OF 1).pdf
pdf • 0.56 MB
474002-400kv 4WT(SH.1 OF 1).pdf
pdf • 0.58 MB
474003-400kv 4CVT(SH.1 OF 1).pdf
pdf • 0.66 MB
474004-400kv 4LA(SH.1 OF 1).pdf
pdf • 0.59 MB
474005-400kv 4ISO(SH.1 OF 1).pdf
pdf • 0.71 MB
474006-400kv 4CT(SH.1 OF 1).pdf
pdf • 0.60 MB
4740710-765kv 7BE(SH.1 OF 2).pdf
pdf • 1.12 MB
4740710-765kv 7BE(SH.2 OF 2).pdf
pdf • 1.14 MB
4740711-765kv 7BF(SH.1 OF 2).pdf
pdf • 1.02 MB
4740711-765kv 7BF(SH.2 OF 2).pdf
pdf • 1.11 MB
4740704-765kv 7CB(SH.1 OF 2).pdf
pdf • 1.14 MB
4740704-765kv 7CB(SH.2 OF 2).pdf
pdf • 0.95 MB
4740705-765kv 7GWCB(SH.1 OF 1).pdf
pdf • 0.98 MB
4740706-765kv 7BC(SH.1 OF 1).pdf
pdf • 1.31 MB
4740707-765kv 7BD(SH.1 OF 1).pdf
pdf • 1.24 MB
4740708-765kv 7CC(SH.1 OF 2).pdf
pdf • 1.03 MB
4740708-765kv 7CC(SH.2 OF 2).pdf
pdf • 1.11 MB
4740709-765kv 7GWCC(SH.1 OF 1).pdf
pdf • 0.90 MB
474001-765kv 7BPI(SH.1 OF 1).pdf
pdf • 0.50 MB
474002-765kv 7WT(SH.1 OF 1).pdf
pdf • 0.50 MB
474003-765kv 7CVT(SH.1 OF 1).pdf
pdf • 0.49 MB
474004-765kv 7LA(SH.1 OF 1).pdf
pdf • 0.51 MB
474005-765kv 7ISO(SH.1 OF 1).pdf
pdf • 0.52 MB
474006-765kv 7CT(SH.1 OF 1).pdf
pdf • 0.55 MB
474007-765kv 7ES(SH.1 OF 1).pdf
pdf • 0.61 MB
4740701-765kv 7CA(SH.1 OF 2).pdf
pdf • 1.01 MB
4740701-765kv 7CA(SH.2 OF 2).pdf
pdf • 0.99 MB
4740702-765kv 7BA(SH.1 OF 1).pdf
pdf • 1.18 MB
4740703-765kv 7BB(SH.1 OF 1).pdf
pdf • 1.16 MB
17. Section-Civil Works_Rev11A.pdf
pdf • 2.00 MB
18. Section-CRP_Rev9.pdf
pdf • 0.37 MB
Appendix-II for SAS_Rev04_STANDARD FACTORY SIMULATION TEST PLAN.pdf
pdf • 0.54 MB
Section-Sub-station Automation_Rev04.pdf
pdf • 0.98 MB
Thumbs.db
db • 0.04 MB
20. Section-PLCC_Rev5.pdf
pdf • 0.06 MB
21. Section-Telecommunication Systems_Rev1.pdf
pdf • 0.54 MB
22. Section-PMU_Rev0.pdf
pdf • 0.59 MB
10. Section-Air conditioning_Rev4.pdf
pdf • 0.04 MB
11. Section-LT Switchgear_Rev5.pdf
pdf • 0.47 MB
12. Section-Battery&Charger_Rev6.pdf
pdf • 1.05 MB
13. Section-Diesel Generator Set_Rev5.pdf
pdf • 0.27 MB
14. Section-LT Transformer_Rev5.pdf
pdf • 0.07 MB
15. Section-Switchyard Erection_Rev10.pdf
pdf • 5.99 MB
16. Section-Structure_Rev6.pdf
pdf • 0.10 MB
9. Section-Fire Protection_Rev6.pdf
pdf • 1.97 MB
Annexure-I List of Drawings - Bhadla2.pdf
pdf • 0.39 MB
Annexure-II Digital Protection Coupler.pdf
pdf • 0.14 MB
Annexure-III Short Description.pdf
pdf • 0.16 MB
Annexure-IV Mandatory Spares Split up.pdf
pdf • 0.21 MB
Annexure-V VMS for watch and ward of substation.pdf
pdf • 0.52 MB
Section-Project, Rev00 BHADLA-2 SS29.pdf
pdf • 0.34 MB
GTR-9.5_List of TTR not required.pdf
pdf • 1.80 MB
Section-GTR, Revision-14.pdf
pdf • 1.19 MB
Thumbs_1.db
db • 0.12 MB
TS of RTV coating_Ammend-I.pdf
pdf • 0.14 MB
3. Section-Switchgear-CB_Rev11.pdf
pdf • 0.61 MB
4. Section-Switchgear-ISO_rev11B.pdf
pdf • 0.11 MB
5. Section-Switchgear-INST_rev11.pdf
pdf • 1.00 MB
6. Section-Switchgear-SA_rev11.pdf
pdf • 0.10 MB
7. Section-Power & Control Cable_Rev6.pdf
pdf • 0.26 MB
8. Section-Lighting Specification_Rev7.pdf
pdf • 4.29 MB
01_First Envelope Attachments and Bid Form_SS29.xlsx
xlsx • 1.13 MB
02_Second Envelope Schedules and Bid Form_SS29.xlsx
xlsx • 1.45 MB
03_Attachment-3 (QR).doc
doc • 0.11 MB
04_Attachment-8_Manufacturer Authorization Form.doc
doc • 0.04 MB
05_Attachment 20_KMP Declaration.doc
doc • 0.04 MB
06_Attachment-21_Affidavit for self-certifictaion.DOCX
docx • 0.02 MB
07_Attachment 22_Certificate by Auditor.docx
docx • 0.02 MB
08_Attachment-23_E-RA Compliance.docx
docx • 0.02 MB
09_Legends for Units.pdf
pdf • 0.03 MB
~$-Annexure-A (BDS).doc
doc • 0.00 MB
~$-Section - III_BDS.docx
docx • 0.00 MB
00-Cover.doc
doc • 2.20 MB
01- IFB.doc
doc • 0.07 MB
02- Section - II ITB SSTE S&I Rev5-DCB-TCIL.pdf
pdf • 1.95 MB
03-Section - III_BDS.docx
docx • 0.05 MB
04-Annexure-A (BDS).doc
doc • 0.06 MB
05- Section - IV GCC -S&I Rev 3-DCB.pdf
pdf • 1.93 MB
06-Section - V_SCC-AIS.doc
doc • 0.09 MB
07-Appendix -I to SCC.doc
doc • 0.39 MB
08-Annexure-I to Section-V (SCC).docx
docx • 0.07 MB
09-Sample Forms and Procedures-AIS.doc
doc • 0.43 MB
4-Annexure-B to BDS.docx
docx • 0.02 MB
4-Annexure-C(BDS).docx
docx • 0.02 MB
4-Annexure-D to BDS.docx
docx • 0.03 MB
Clarification No -II.pdf
pdf • 0.27 MB
Corrigendum_file_SS29.pdf
pdf • 0.76 MB
Clarification_No-I_-SS29-.pdf
pdf • 0.46 MB
OBD_EXTN_LETTER-SS29.pdf
pdf • 0.13 MB
Amendment No.-II_SS29.doc
doc • 0.19 MB
Amendment No.-I _SS29.doc
doc • 0.12 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .