| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹67 LAccepted-AOC C 27 MANOJ C 27 SUKHWANI GANESH NAGAR DAPODI DAPODI PUNE MAHARASHTRA 411012 | PUNE | MAHARASHTRA | 411012 | L1 | Accepted-AOC As per approval of the Competent Authority | |
| 2 | L2₹82.4 L+₹15.4 L (22.9%)Rejected-Finance 301 VARDHAMAN CHAMBER II VIKASPURI NEW DELHI 110018 | WEST | DELHI | 110018 | L2 | Rejected-Finance As per TEC Report | |
| 3 | L3₹1.0 Cr+₹36.5 L (54.4%)Rejected-Finance | L3 | Rejected-Finance As per TEC Report | |
| 4 | Rejected-Technical 355 85 GALI NO 16 ASHOK VIHAR PHASE II BHIM GARH KHERI ASHOK VIHAR PHASE II GURGAON GURGAON HARYANA 122001 | GURUGRAM | HARYANA | 122001 | - | Rejected-Technical As per Evaluation report approved by CA |
Tender Value
Refer Docs
Closing Date
8 Jun 2021, 6:55 pmClosed
DGM (PnC)
Dy General Manager PnC Parbati HE Project Stage-II Parbati Complex Nagwain, Distt. Mandi Pin - 175 121
Restoration of HVAC System Supply of spares, repairing, rectification, re-installation, testing and commissioning of damaged HVAC system in Power House of Parbati H.E. Project (Stage-II) (Package No. PROC-1858)
2021_NHPC_628781_1
NH/PP-II/PnC/Pkg. No. PROC-1858/2021
Open Tender
Miscellaneous Works
Works
150 days
Power House of PHEP-II, Sainj, Kullu(H.P.)
Please refer the tender document
8 documents required · 8 mandatory
₹1,180
NHPC Ltd
Exempted
18 Aug 2021
4 May 2021
14 Jun 2021
4 May 2021
8 Jun 2021
4 May 2021
(A) Supply of materials
Pressure Gauge Liquid Filled (Range:0-10Kg/Cm², Round Type, Dial Size: 150mm, Connection: 3/8" BSP, Body Frame SS, Mounting: Bottom surface mount)
Thermometer/Temperature Meter for measuring water temperature in pipe line (Range:-10° to +50°C, Round Type, Indication: Red Spirit, Body Frame SS)
Three way Motorized Valve (90Nm,240V, 150s, 9.0VA, 5.0W,Size:150mm)
Air-Vent (1/2 inch, Pressure up to 10Kg/cm²)
Three Way Motorized Valve (1000N,24V, 150sec/20mm, 3.0VA, 1.5W, Size: 80mm)
Analog Thermostat (24Volt,Measuring Range-0° to 50°C, Signal Output: Active, DC 0 to 10V)
AHU Supply Damper Motor (Nominal voltage AC 24 V, 50/60 Hz / DC 24 V, Torque (nominal torque) Min. 20 Nm @ nominal voltage, Running time 150 s / 90°,Power consumption, in operation 2W @ nominal torque, For wire sizing 4VA)
AHU Supply Damper Motor (Nominal voltage AC 24...240 V / DC 24...125 V, Nominal voltage frequency 50/60 Hz, Power consumption in operation 6 W, Power consumption for wire sizing 9.5 VA, Running time motor 75 s / 90°, Running time emergency control position <20 s / 90°)
AHU Supply Damper (Size-580X580mm, Holes of 10mm dia for fixing the damper, Blades: GSS/20SWG, Frame: GSS/20SWG)
Three Way Motorized Valve (2500N, AC/DC: 24V, 150sec/40mm,6VA, 4.0W, Size:80mm)
1 C X 630 s.q. mm HRPVC FRLS aluminum armoured LT cable
3.5 C X 400 Sq mm HRPVC FRLS Aluminum armoured LT Cable
3.5 C X 120 Sq mm HRPVC FRLS Aluminum armoured LT Cable
3 C X 120 Sq mm HRPVC FRLS Aluminum armoured LT Cable
3 C X 25 Sq mm PVC FRLS Aluminum armoured LT Cable
4 C X 16 Sq mm PVC FRLS Aluminum armoured LT Cable
3 C X 6 Sq mm PVC FRLS Aluminum armoured LT Cable
3 C X 1.5 Sq mm PVC FRLS Aluminum armoured LT Cable
4 C X 1.5 Sq mm PVC FRLS Aluminum armoured LT Cable
Optical Fiber Cable (OFC)-6 Core
HIGH STATIC EXSHUST FAN ( Capacity of flow:4000 CMH, Noise level of fan <=85dB, Motor rating<1KW)
GI Earth Strip 50X6 mm
8 SWG GI earth wire confirming to IS:280/1978.
(B) Execution of WorK
Insulation work - Supply and Fixing 50 MM thick Thermocol pipe sections with CPRX and covered with Vapour barrier polythene sheet of 120 GSM & 26 gauge Aluminum Cladding.
Duct Cleaning- Removing, Cleaning and refixing of Supply & Return Air Grills & diffusers, cleaning inner surfaces of HVAC ducts by using High Pressure Vacuum, having HEPA filter, Air-Compressor, Robotic Camera & Brushes. The making of CD of videography before, during & duct cleaning process.
SUPPLY, INSTALATION, TESTING & COMMISSIONING OF NEW DUCT.
AHU SERVICE-Complete Servicing of AHU, Cleaning of AHU Coils with 100% Eco-Friendly chemical, Alignment of AHU & Blower Pulley, Greasing of AHU Motor.
Repairing, Rectification, Re-installation, Testing and Complete Commissioning of above components of the HVAC system.
Arctic Engineering Services
APC Air Systems Pvt. Ltd.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .