Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹20 L
EMD Value
₹20,000
Closing Date
11 Feb 2026, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
kim ind division
ARC work of Attend the cable fault at site within 03 HRS from receiving the message from D.E OF concern S/DN AND Locating the Fault underground Cable for ALL scheme in the jurisdiction of Sayan S/dn of KIM Division. Through outsourced agency for existing DGVCL Network for SDN under Kim Division.
272255
KIM/O&M/TECH/N-PROCURE/25-26/08/SR-51 DT:03-02-2026
Open
Electrical and Maintenance Works
Works
Surat
5 documents required · 5 mandatory
₹1,180
DAKSHIN GUJARAT VIJ COMPANY LTD.
₹20,000
3 Feb 2026
3 Feb 2026
3 Feb 2026
11 Feb 2026
3 Feb 2026
ARC work of Attend the cable fault at site within 03 HRS from receiving the message from
D.E OF concern S/DN AND Locating the Fault underground Cable for ALL scheme in the
jurisdiction of Sayan S/dn of KIM Division.
Item Code No. Description Unit Rate Amount
Labour charge for excavation of cable trench of Meter
400mm width x 1200mm depth, in any type of soil
1 9925000001 for laying of cable of size up to 240 mm2 (For
additional cable 200 mm additional width shall be
considered i.e. half trench length is to be considered
Labour charge for excavation of cable trench of Meter
600mm width x 1200mm depth, in any type of soil
2 9925000002 for laying of cable of size up to 240 mm2 (For
additional cable 200 mm additional width shall be
considered i.e. half trench length is to be considered
Labour charge for excavation of cable trench of Meter
400mm width x 1500mm depth, in any type of soil
for laying of cable of size up to 240 mm2 (For
additional cable 200 mm additional width shall be
considered i.e. half trench leng th is to be
Labour charge for laying of 11kV / 22 kV XLPE Meter
Cable of size up to 240 mm2 & preparation of sand
layer 100mm thick, in the cable trench & covering
the cable with 150 mm dia (Outer), thickness
mm, 1.0 meter long RCC half round muffs and
providing and fixing of 4inch width yellow colour
4 9925000004 polyethylene tape with printing"CAUTION
ELECTRIC CABLE BELOW' at 0.75 m depth from
ground surface after laying cable in trench. This will
provide indication that electric cable is passing
underground so as to protect cable from mechanical
injuries, refilling the same, as per Instruction of E
gineer in Charge (EIC) .
File No: DGVCLDOKI/TEN/e-file/6817/2026/0590/Account
Approved By: Executive Engineer,Technical,DGVCLDOKI
Letter No: DGVCLDOKI/0034/02/2026 Approved Date: 02-02-2026
Labour charge for horizontal drilling using Auger Meter
machine without damage to surface road at max
mtrs depth & putting of 6.11 kg/cm2 , class-4,Green
color, 110mm 0.D. 8.5mm thickness H.D.P.E. pipe
confirms to IS 4984-1987(3rd revision) and BIS
certification and laying of 11KV/22KV XLPE cable of
size up to 240 mm2 in HDPE pipe, as per Site
Condition (excluding cost of pipe). The detail map
obtained from HDD machine and excel sheet hard
and soft copy) indicating the respective depth and
distance from adjacent landmark for each segment
for HDD is must require to be submitted. HDD to be
carried out at depth 1.5 mtrs to 2.0 mtrs as per site
conditions and as er instruction of EIC.
Labour charge for horizontal drilling manually without Meter
damage to surface road at max 2.0 mtrs depth &
putting of 6.11 kg/cm2 , class-4,Green color, 110mm
O.D. , 8.5mm thickness H.D.P.E. pipe confirms to IS
4984-1987(3rd revision) and BIS certification and
laying of 11KV/22KV XLPE cable of size up to
6 9925000006 mm2 size, as per Site Condition (excluding cost of
pipe). The detail map and excel sheet (hard and soft
copy) indicating the respective depth and distance
from adjacent landmark for each segment of cable to
be submitted. Drilling to be carried out at depth
Minimum 1.2 mtrs to 2.0 mtrs as per site conditions
as per instruction of EIC.
Supply of 6.11kg/cm2 , class-4,Green color, 110mm Meter
O.D. , 8.5 mm thickness H.D.P.E. pipe confirms to
7 9925000007 IS 4984 and BIS certification for laying of
underground 11KV/ 22KV XLPE cable up to 240 mm
Labour work for RCC concreting on disputed CMT
location and repairing of damage portion of road
8 9925000008 crossing for the work carried out for roads crossing
as well as concreting & muffing of poles including all
Providing & fixing concrete stone route marker of No
300 mm width x 150 mm thick x 650 mm height
embedded in earth at least 300 mm below &
mm above ground level respectively at distance
approx. 50 meters along the length of cable. The
RCC concreting (1:2:4)(all necessary materials
will be in bidder's scope) of route marker is to be
carried out 300 mm width x 150 mm thick x 300 mm
9 9925000009 below ground level as per instruction of EIC. The
route marker should be with name of company with
approved yellow colour-DGVCL. The distance from
marker to cable and cable depth with feeder name
etc., marked with arrow sign is to be painted on it.
The route marker is to be fixed at location near to
any fixed permanent location (not necessary to fix
exact on top of cable) as per instruction of EIC.
File No: DGVCLDOKI/TEN/e-file/6817/2026/0590/Account
Approved By: Executive Engineer,Technical,DGVCLDOKI
Letter No: DGVCLDOKI/0034/02/2026 Approved Date: 02-02-2026
Labour charge for erecting of 11kV / 22 kV XLPE perJob
cable of size up to 240 mm 2 on DP Structure with
10 9925000014 fixing of 02 Nos polymer cleats on top and middle
part. Polymer cleats, nut bolts etc. fixing material to
be provided by contractor.
Providing & fixing of 6.11kg/cm2 , class4,Green perJob
color, 110mm O.D. 8.5mm thickness H.D.P.E. pipe
confirms to IS 4984 and BIS certification on the
erected DP structure for the mechanical protection
of cable by inserting the cable inside HDPE pipe.
11 9925000015 The HDPE pipe shall be erected in such a way that
300mm shall be below the ground level and the rest
2700 mm shall be supported on the DP Structure
with 01 No Polymer cleat. All materials including
polymer cleat and Nut bolt to be provided by
Providing and fixing of pipe type earthing from 80 No
mm dia class-B GI pipe with pit to be filled with salt
& coke and construction of chamber as per DGVCL
1 9925000016 Drg. No. dg /100 for DP and cable. The earthing pit
should be joined with cable by G.I. strip of size 1"
width & 2 mm thick. All material GI pipe, Coke Salt
etc will be supplied by bidder.
Supply & fixing of heat shrink type end terminations No
1 9925000017 (outdoor) for up to 11kV 3C x 185 mm2 size XLPE
cable as per DGVCL technical s ecification
Supply & fixing of heat & shrinkable end No
terminations (outdoor) for up to 22 kV 3C x 185 mm
2 size XLPE cable ( as per DGVCL technical
Supply & fixing of heat shrinkable type end No
terminations (indoor) for up to 11kV 3C x 185 mm
size XLPE cable as per DGVCL technical
Supply & fixing of heat & shrinkable end No
9925000020 terminations (indoor) for up to 22 kV 3C x 185 mm
size XLPE cable as per DGVCL technical
Supply & fixing of heat shrinkable straight through No
5 9925000021 joint for up to 11kV 3C x 185 mm 2 size XLPE
cables as per DGVCL technical specification.
Supply & fixing of heat shrinkable straight through No
6 9925000022 joint type for up to 22kV 3C x 185 mm 2 size XLPE
cable as per DGVCL technical specification
Labour charge for excavation of 2100mm long x No
1200mm wide x 1200 mm deep joint pits for
installation of 11kV / 22kV Straight through joints as
7 9925000023 per instruction of engineer-in-charge & covering the
cable with 150 mm dia (Outer), thickness 25 mm,
1.0 meter long RCC half round muffs & refilling
same as per instruction of EIC .
File No: DGVCLDOKI/TEN/e-file/6817/2026/0590/Account
Approved By: Executive Engineer,Technical,DGVCLDOKI
Letter No: DGVCLDOKI/0034/02/2026 Approved Date: 02-02-2026
Providing and fixing of insulating bus bar, made from No
11KV/22KV XLPE cable after removal of semi
conducting layer and applying of PVC heat
shrinkable antitracking core insulating tubing
(1.1KV), on both end terminal using Aluminium long
barrel heavy duty up to 240 sq mm lugs, Aluminium
bus connector. Taping with PGclamp for bus
conductor as per drawing and as per instruction of
EIC. The Allurninium lugs and PG clamp shall be
covered with 11KV/22KV HT insulating tapes.
(11KV/22KV XLPE cable will be in scope of DGVCL
while all other materials will be in bidder's scope.
Testing of cable at various points and No
commissioning the feeder as per instruction of
engineer-in-charge.Test result shall be submitted by
contractor with bill.
Preparation and submission of 6 (six) copies, of Set
complete layout drawings with GIS mapping as per
actual cable routing showing road crossing, HDPE
pipe sleeving, jointing locations, markers etc.
To Attend the cable fault at site within 03 hrs from No
9 9925000047 receiving the message from D.E of concern S/dn
and locating the fault under ground cable.
TOTAL AMOUNT :-Twenty Lacs Only 20,00,000/-
TOTAL AMOUNT :-Twenty Lacs Only 20,00,000/-
Executive Engineer
DGVCL, KIM IND DIVISION.
File No: DGVCLDOKI/TEN/e-file/6817/2026/0590/Account
Approved By: Executive Engineer,Technical,DGVCLDOKI
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
2.1 Tender Notice 25-26-08-51.pdf
2.2 N-procure.pdf
2.3 Technical Specification.pdf
2.4 Bid Document terms and condition.pdf
2.5 Schedule B 25-26-08-51.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .