Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.0 LAccepted-AOC NABAJIBAN 1 NABAJIBAN COLONY BISHARPARA KOLKA 700158 WEST BENGAL | KOLKATA | KOLKATA | WEST BENGAL | 700158 | L1 | Accepted-AOC Being L1 Bidder. | |
| 2 | L2₹3.6 L+₹58,334 (19.4%)Rejected-Finance 33 PEMANTLE STREET KOLKATA 700016 | KOLKATA | KOLKATA | WEST BENGAL | 700016 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹3.6 L+₹62,582 (20.9%)Rejected-Finance 10B DR LAHIT BANERJEE SARANI GROUND FLOOR KOLKATA 700 073 | KOLKATA | KOLKATA | WEST BENGAL | 700073 | L3 | Rejected-Finance Not being L1 |
| Sl No | Description | Qty | Unit | CARRION AIR COOLING L3 | MILLENNIUM AIRCON L2 | ANIKET COOLING AND REFRIGERATION CO L1 |
|---|---|---|---|---|---|---|
| 1.00 | Dismantling the existing damaged insulation with necy. Tools and tackels by skilled technician as per direction of EIC. | 1 | LOT | 19,084 ₹19,084 | 18,777 ₹18,777 | 15,351 ₹15,351 Lowest |
| 2.00 | Supply and fixing of 1-5/8" dia with 19 mm thick nitrile rubber insulation along with ancillary materials. | 168 | RM | 832 ₹1,39,776 | 788 ₹1,32,384 | 657 ₹1,10,376 Lowest |
| 3.00 | Supply and fixing of 1-3/8" dia with 19 mm thick nitrile rubber insulation along with ancillary materials. | 72 | RM | 771 ₹55,512 | 633 ₹45,576 | 603 ₹43,416 Lowest |
| 4.00 | Supply and fixing of 1-1/8" dia with 19 mm thick nitrile rubber insulation along with ancillary materials. | 10 | RM | 622 ₹6,220 | 699 ₹6,990 | 559 ₹5,590 Lowest |
| 5.00 | Supply and fixing of 3/4" dia with insulation along with ancillary 13 mm thick nitrile rubber materials | 168 | RM | 447 ₹75,096 | 477 ₹80,136 | 394 ₹66,192 Lowest |
| 6.00 | Supply and fixing of 5/8" dia with 13 mm thick nitrile rubber insulation along with ancillary materials. | 72 | RM | 398 ₹28,656 | 399 ₹28,728 | 351 ₹25,272 Lowest |
| 7.00 | Supply and fixing of 1/2" dia with 13 mm thick nitrile rubber insulation along with ancillary materials. | 10 | RM | 298 ₹2,980 | 355 ₹3,550 | 263 ₹2,630 Lowest |
| 8.00 | Making one set of scaffolding only for replacing glass panels, painting, uprooting plant and another repairing works of building and S&P works for external works only with 10 cm. dia bamboo as main posts at the rate of 1 metre centre to centre and 7.5 cm. dia bamboo ties @ 0.75 metre apart fitting and fixing with necessary coir, nails etc. as per direction of the Engineer-incharge.
(This item should be executed only after prior approval of the Engineer- incharge). Firstly, one number to be paid and then labour rate for shifting up to further nineteenth (19) times @ 10% each time to be considered. lf necessary further after twenty times of total use, another one number new and labour rate for shifting to be considered accordingly.
(a) 3.9 meter height | 95 | each | 371 ₹35,245 | 444 ₹42,180 | 328 ₹31,160 Lowest |
| 9.00Note: 1) All the above rates should be quoted inclusive of all taxes, duties and all ancilery charges with cost of maintenance, servicing, supply & replacement of spares for 1 (One) year from the date of commissioning. | ||||||
Tender Value
Refer Docs
EMD Value
₹7,551
Closing Date
15 Jan 2026, 1:00 pmClosed
Assistant Engineer, BESD-II,Purta Bhawan, room-13
Assistant Engineer, BESD-II,Purta Bhawan, room-13,700091.
Repair and replacement of insulation of copper pipe line of existing VRF system at ARDD Building LB Block Salt Lake Kolkata
2025_WBPWD_977068_1
WBPWD/AE/BESD-II/e-NIQ06/25-26
Open Tender
ELECTRICAL WORKS M/R
Item Rate
ARDD Building, LB Block, Salt Lake, Kolkata.
Please refer Tender documents.
4 documents required · 4 mandatory
₹7,551
Bidhannagar Electrical Sub-Divn-II
13 May 2026
19 Dec 2025
19 Jan 2026
19 Dec 2025
15 Jan 2026
30 Dec 2025
29 Dec 2025
Dismantling the existing damaged insulation with necy. Tools and tackels by skilled technician as per direction of EIC.
Supply and fixing of 1-5/8" dia with 19 mm thick nitrile rubber insulation along with ancillary materials.
Supply and fixing of 1-3/8" dia with 19 mm thick nitrile rubber insulation along with ancillary materials.
Supply and fixing of 1-1/8" dia with 19 mm thick nitrile rubber insulation along with ancillary materials.
Supply and fixing of 3/4" dia with insulation along with ancillary 13 mm thick nitrile rubber materials
Supply and fixing of 5/8" dia with 13 mm thick nitrile rubber insulation along with ancillary materials.
Supply and fixing of 1/2" dia with 13 mm thick nitrile rubber insulation along with ancillary materials.
Making one set of scaffolding only for replacing glass panels, painting, uprooting plant and another repairing works of building and S&P works for external works only with 10 cm. dia bamboo as main posts at the rate of 1 metre centre to centre and 7.5 cm. dia bamboo ties @ 0.75 metre apart fitting and fixing with necessary coir, nails etc. as per direction of the Engineer-incharge. (This item should be executed only after prior approval of the Engineer- incharge). Firstly, one number to be paid and then labour rate for shifting up to further nineteenth (19) times @ 10% each time to be considered. lf necessary further after twenty times of total use, another one number new and labour rate for shifting to be considered accordingly. (a) 3.9 meter height
Note: 1) All the above rates should be quoted inclusive of all taxes, duties and all ancilery charges with cost of maintenance, servicing, supply & replacement of spares for 1 (One) year from the date of commissioning.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.16 MB
2911.pdf
Tender Documents • 0.56 MB
BOQ_2380599.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .