| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.5 LAccepted-AOC GSTIN: 02AIGPT9617A1ZG | ₹9.5 L | L1 | Accepted-AOC Quoted rates are lowest |
| 2 | L2₹12.6 LRejected-Finance | ₹12.6 L | L2 | Rejected-Finance Quoted rates are higher |
| 3 | L3₹14.6 LRejected-Finance | ₹14.6 L | L3 | Rejected-Finance Quoted rates are higher |
| 4 | Rejected-Technical | - | - | Rejected-Technical bidder was not technicaly qualify |
| 5 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical EMD/Fee not received |
| Sl No | Description | Qty | Unit | ARUN CONSTRUCTIONS L1 | Y.M Sales Corporation L3 | M/S OASIS ENTERPRISES L2 |
|---|---|---|---|---|---|---|
| 1.00 | Supplying of centrifugal pump having horizontal spindle, horizontal/redial split casting /end suction (back -pull our arrangement)single /double /in series /parallel of recommended make such as Mather and platt/KSB as per BIS 1520-1980 with upto date amendments read with is 9137-1978 or latest edition suitable for lifting water for under mentioned characteristics with bronze. impellers /priming funnels, casting ring and shaft sleeves of bronze, shaft of steel grade 4508 FNB with cast iron casing coupled directly through a flexible coupling to slip ring it should include cost of bearing nuts, bolts and painting and should meet the following requirements : same size and specification as already installed in the water treatment scheme.
Discharge (Q):- 70 m3/h
Head :- 230 meter pumping hours 8 hours characteristics of water clear :- cold water Rising main dia 150mm as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift. | 1 | Set | 5,60,000 ₹5.6 L | 4,80,000 ₹4.8 L | 4,28,800 ₹4.3 L |
| 2.00 | Supplying of centrifugal pump having horizontal spindle, horizontal/redial split casting /end suction (back -pull our arrangement)single /double /,in series /parallel of recommended make such as Mather and platt/KSB as per BIS 1520-1980 with upto date amendments read with is 9137-1978 or latest edition suitable for lifting water for under mentioned characteristics with bronze impellers /priming funnels ,casting ring and shaft sleeves of bronze, shaft of steel grade 4508FNB with cast iron casing coupled directly through a flexible coupling to slip ring it should include cost of bearing nuts, bolts and painting and should meet the following requirements : same size and specification as already installed in the water treatment scheme.
Discharge (Q) :- 70 m3/h Head :- 70 meter pumping hours 8 hours characteristics of water clear:- cold water Rising main dia 150mm as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift. | 1 | Set | 2,40,000 ₹2.4 L | 4,18,000 ₹4.2 L | 2,84,800 ₹2.8 L |
| 3.00 | Supplying of 100 H.P. induction motor /motor of standard make such as KSB /martion and suitable for operation on 400(+/-)10% volts ,50 cycles /second. 3phase AC electric supply the power of electric motor should be at 10% in excess of the maximum power required by the pump in operation range of +10% and (-)15% of the duty point head, the motor as per ISI:325:1978 with upto date amendment read with IS 900;1972,it should include cost of bearing nuts, bolts and painting and should meet the following requirements: same size and specification as already installed in the water treatment scheme.
Output HP : 100 Hp
Voltage:415V
Phase:3 Output KW 75 kW
Frequency :50 Hz as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift. | 1 | Set | 80,000 ₹80,000 | 3,98,000 ₹4.0 L | 3,97,000 ₹4.0 L |
| 4.00 | Supplying of 40 H.P. induction motor /motor of standard make such as KSB /martion and suitable for operation on 400(+/-)10% volts ,50 cycles /second. 3phase AC electric supply. The power of electric motor should be at 10% in excess of the maximum power required by the pump in operation range of +10% and (-)15% of the duty point head .the motor as per ISI:325:1978 with upto date amendment read with IS 900;1972,it should include cost of bearing nuts, bolts and painting and should meet the following requirements: same size and specification as already installed in the water treatment scheme.
Output HP : 40 Hp
Voltage:415V Phase: 3 Output KW 30 kW
Frequency :50 Hz as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift. | 1 | Set | 69,000 ₹69,000 | 1,68,000 ₹1.7 L | 1,53,200 ₹1.5 L |
Tender Value
₹12.4 L
EMD Value
₹24,886
Closing Date
1 Jul 2025, 6:00 pmClosed
Superintending Engineer IIT Mandi Kamand
O/o Superintending Engineer, IIT Mandi, South Campus Kamand Distt. Mandi HP-175075
SITC of two nos of centrifugal pump having capacity 70 m3/h and induction motor having capacity 100HP and 40 HP for Water Treatment Plant at south Campus of IIT Mandi.
2025_IITMD_863985_1
IIT Mandi (CW)/SE-1759/2025-26/ 709-11 dated 09-06-2025
Open Tender
Civil Works
45 days
South Campus of IIT Mandi
Please refer to NIT
2 documents required · 2 mandatory
₹1,180
The Registrar IIT Mandi
₹24,886
2 Feb 2026
10 Jun 2025
3 Jul 2025
10 Jun 2025
1 Jul 2025
10 Jun 2025
10 Jun 2025 - 30 Jun 2025
Amount
Supplying of centrifugal pump having horizontal spindle, horizontal/redial split casting /end suction (back -pull our arrangement)single /double /in series /parallel of recommended make such as Mather and platt/KSB as per BIS 1520-1980 with upto date amendments read with is 9137-1978 or latest edition suitable for lifting water for under mentioned characteristics with bronze. impellers /priming funnels, casting ring and shaft sleeves of bronze, shaft of steel grade 4508 FNB with cast iron casing coupled directly through a flexible coupling to slip ring it should include cost of bearing nuts, bolts and painting and should meet the following requirements : same size and specification as already installed in the water treatment scheme. Discharge (Q):- 70 m3/h Head :- 230 meter pumping hours 8 hours characteristics of water clear :- cold water Rising main dia 150mm as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift.
Supplying of centrifugal pump having horizontal spindle, horizontal/redial split casting /end suction (back -pull our arrangement)single /double /,in series /parallel of recommended make such as Mather and platt/KSB as per BIS 1520-1980 with upto date amendments read with is 9137-1978 or latest edition suitable for lifting water for under mentioned characteristics with bronze impellers /priming funnels ,casting ring and shaft sleeves of bronze, shaft of steel grade 4508FNB with cast iron casing coupled directly through a flexible coupling to slip ring it should include cost of bearing nuts, bolts and painting and should meet the following requirements : same size and specification as already installed in the water treatment scheme. Discharge (Q) :- 70 m3/h Head :- 70 meter pumping hours 8 hours characteristics of water clear:- cold water Rising main dia 150mm as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift.
Supplying of 100 H.P. induction motor /motor of standard make such as KSB /martion and suitable for operation on 400(+/-)10% volts ,50 cycles /second. 3phase AC electric supply the power of electric motor should be at 10% in excess of the maximum power required by the pump in operation range of +10% and (-)15% of the duty point head, the motor as per ISI:325:1978 with upto date amendment read with IS 900;1972,it should include cost of bearing nuts, bolts and painting and should meet the following requirements: same size and specification as already installed in the water treatment scheme. Output HP : 100 Hp Voltage:415V Phase:3 Output KW 75 kW Frequency :50 Hz as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift.
Supplying of 40 H.P. induction motor /motor of standard make such as KSB /martion and suitable for operation on 400(+/-)10% volts ,50 cycles /second. 3phase AC electric supply. The power of electric motor should be at 10% in excess of the maximum power required by the pump in operation range of +10% and (-)15% of the duty point head .the motor as per ISI:325:1978 with upto date amendment read with IS 900;1972,it should include cost of bearing nuts, bolts and painting and should meet the following requirements: same size and specification as already installed in the water treatment scheme. Output HP : 40 Hp Voltage:415V Phase: 3 Output KW 30 kW Frequency :50 Hz as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift.
M/S OASIS ENTERPRISES (BID ID -3235150)
Y.M Sales Corporation (BID ID -3235558)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid