Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.5 LAccepted-AOC | ₹9.5 L | L1 | Accepted-AOC Quoted rates are lowest |
| 2 | L2₹12.6 L+₹3.1 L (33.2%)Rejected-Finance | ₹12.6 L+₹3.1 L (33.2%) | L2 | Rejected-Finance Quoted rates are higher |
| 3 | L3₹14.6 L+₹5.2 L (54.3%)Rejected-Finance | ₹14.6 L+₹5.2 L (54.3%) | L3 | Rejected-Finance Quoted rates are higher |
| 4 | Rejected-Technical | - | - | Rejected-Technical bidder was not technicaly qualify |
| 5 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical EMD/Fee not received |
| Sl No | Description | Qty | Unit | ARUN CONSTRUCTIONS L1 | Y.M Sales Corporation L3 | M/S OASIS ENTERPRISES L2 |
|---|---|---|---|---|---|---|
| 1.00 | Supplying of centrifugal pump having horizontal spindle, horizontal/redial split casting /end suction (back -pull our arrangement)single /double /in series /parallel of recommended make such as Mather and platt/KSB as per BIS 1520-1980 with upto date amendments read with is 9137-1978 or latest edition suitable for lifting water for under mentioned characteristics with bronze. impellers /priming funnels, casting ring and shaft sleeves of bronze, shaft of steel grade 4508 FNB with cast iron casing coupled directly through a flexible coupling to slip ring it should include cost of bearing nuts, bolts and painting and should meet the following requirements : same size and specification as already installed in the water treatment scheme.
Discharge (Q):- 70 m3/h
Head :- 230 meter pumping hours 8 hours characteristics of water clear :- cold water Rising main dia 150mm as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift. | 1 | Set | 5,60,000 ₹5,60,000 | 4,80,000 ₹4,80,000 | 4,28,800 ₹4,28,800 Lowest |
| 2.00 | Supplying of centrifugal pump having horizontal spindle, horizontal/redial split casting /end suction (back -pull our arrangement)single /double /,in series /parallel of recommended make such as Mather and platt/KSB as per BIS 1520-1980 with upto date amendments read with is 9137-1978 or latest edition suitable for lifting water for under mentioned characteristics with bronze impellers /priming funnels ,casting ring and shaft sleeves of bronze, shaft of steel grade 4508FNB with cast iron casing coupled directly through a flexible coupling to slip ring it should include cost of bearing nuts, bolts and painting and should meet the following requirements : same size and specification as already installed in the water treatment scheme.
Discharge (Q) :- 70 m3/h Head :- 70 meter pumping hours 8 hours characteristics of water clear:- cold water Rising main dia 150mm as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift. | 1 | Set | 2,40,000 ₹2,40,000 Lowest | 4,18,000 ₹4,18,000 | 2,84,800 ₹2,84,800 |
| 3.00 | Supplying of 100 H.P. induction motor /motor of standard make such as KSB /martion and suitable for operation on 400(+/-)10% volts ,50 cycles /second. 3phase AC electric supply the power of electric motor should be at 10% in excess of the maximum power required by the pump in operation range of +10% and (-)15% of the duty point head, the motor as per ISI:325:1978 with upto date amendment read with IS 900;1972,it should include cost of bearing nuts, bolts and painting and should meet the following requirements: same size and specification as already installed in the water treatment scheme.
Output HP : 100 Hp
Voltage:415V
Phase:3 Output KW 75 kW
Frequency :50 Hz as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift. | 1 | Set | 80,000 ₹80,000 Lowest | 3,98,000 ₹3,98,000 | 3,97,000 ₹3,97,000 |
| 4.00 | Supplying of 40 H.P. induction motor /motor of standard make such as KSB /martion and suitable for operation on 400(+/-)10% volts ,50 cycles /second. 3phase AC electric supply. The power of electric motor should be at 10% in excess of the maximum power required by the pump in operation range of +10% and (-)15% of the duty point head .the motor as per ISI:325:1978 with upto date amendment read with IS 900;1972,it should include cost of bearing nuts, bolts and painting and should meet the following requirements: same size and specification as already installed in the water treatment scheme.
Output HP : 40 Hp
Voltage:415V Phase: 3 Output KW 30 kW
Frequency :50 Hz as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift. | 1 | Set | 69,000 ₹69,000 Lowest | 1,68,000 ₹1,68,000 | 1,53,200 ₹1,53,200 |
Tender Value
₹12.4 L
EMD Value
₹24,886
Closing Date
1 Jul 2025, 6:00 pmClosed
Superintending Engineer IIT Mandi Kamand
O/o Superintending Engineer, IIT Mandi, South Campus Kamand Distt. Mandi HP-175075
SITC of two nos of centrifugal pump having capacity 70 m3/h and induction motor having capacity 100HP and 40 HP for Water Treatment Plant at south Campus of IIT Mandi.
2025_IITMD_863985_1
IIT Mandi (CW)/SE-1759/2025-26/ 709-11 dated 09-06-2025
Open Tender
Civil Works
Item Rate
45 days
South Campus of IIT Mandi
Please refer to NIT
2 documents required · 2 mandatory
₹1,180
The Registrar IIT Mandi
₹24,886
2 Feb 2026
10 Jun 2025
3 Jul 2025
10 Jun 2025
1 Jul 2025
10 Jun 2025
10 Jun 2025 - 30 Jun 2025
Amount
Supplying of centrifugal pump having horizontal spindle, horizontal/redial split casting /end suction (back -pull our arrangement)single /double /in series /parallel of recommended make such as Mather and platt/KSB as per BIS 1520-1980 with upto date amendments read with is 9137-1978 or latest edition suitable for lifting water for under mentioned characteristics with bronze. impellers /priming funnels, casting ring and shaft sleeves of bronze, shaft of steel grade 4508 FNB with cast iron casing coupled directly through a flexible coupling to slip ring it should include cost of bearing nuts, bolts and painting and should meet the following requirements : same size and specification as already installed in the water treatment scheme. Discharge (Q):- 70 m3/h Head :- 230 meter pumping hours 8 hours characteristics of water clear :- cold water Rising main dia 150mm as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift.
Supplying of centrifugal pump having horizontal spindle, horizontal/redial split casting /end suction (back -pull our arrangement)single /double /,in series /parallel of recommended make such as Mather and platt/KSB as per BIS 1520-1980 with upto date amendments read with is 9137-1978 or latest edition suitable for lifting water for under mentioned characteristics with bronze impellers /priming funnels ,casting ring and shaft sleeves of bronze, shaft of steel grade 4508FNB with cast iron casing coupled directly through a flexible coupling to slip ring it should include cost of bearing nuts, bolts and painting and should meet the following requirements : same size and specification as already installed in the water treatment scheme. Discharge (Q) :- 70 m3/h Head :- 70 meter pumping hours 8 hours characteristics of water clear:- cold water Rising main dia 150mm as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift.
Supplying of 100 H.P. induction motor /motor of standard make such as KSB /martion and suitable for operation on 400(+/-)10% volts ,50 cycles /second. 3phase AC electric supply the power of electric motor should be at 10% in excess of the maximum power required by the pump in operation range of +10% and (-)15% of the duty point head, the motor as per ISI:325:1978 with upto date amendment read with IS 900;1972,it should include cost of bearing nuts, bolts and painting and should meet the following requirements: same size and specification as already installed in the water treatment scheme. Output HP : 100 Hp Voltage:415V Phase:3 Output KW 75 kW Frequency :50 Hz as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift.
Supplying of 40 H.P. induction motor /motor of standard make such as KSB /martion and suitable for operation on 400(+/-)10% volts ,50 cycles /second. 3phase AC electric supply. The power of electric motor should be at 10% in excess of the maximum power required by the pump in operation range of +10% and (-)15% of the duty point head .the motor as per ISI:325:1978 with upto date amendment read with IS 900;1972,it should include cost of bearing nuts, bolts and painting and should meet the following requirements: same size and specification as already installed in the water treatment scheme. Output HP : 40 Hp Voltage:415V Phase: 3 Output KW 30 kW Frequency :50 Hz as per entire satisfaction and direction of Engineer -in-charge including carriage of material within all lead and lift.
M/S OASIS ENTERPRISES (BID ID -3235150)
Y.M Sales Corporation (BID ID -3235558)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .