| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.0 CrAccepted-AOC COLLEGE ROAD JASHPUR NAGAR CHHATTISGARH 496331 | JASHPUR NAGAR | JASHPUR | CHHATTISGARH | 496331 | ₹45.0 Cr | L1 | Accepted-AOC L1 Letter No. 655(S)WE Date-17.02.2023 |
| 2 | L2₹45.4 CrRejected-Finance | ₹45.4 Cr | L2 | Rejected-Finance L2 Letter No. 655(S)WE Date-17.02.2023 |
| 3 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 4 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 5 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹41.3 Cr
EMD Value
₹41.3 L
Closing Date
30 Jan 2023, 12:00 pmClosed
E.E. RCD ROAD DIVISION GUMLA
E.E. RCD ROAD DIVISION GUMLA
Reconstruction of Agharma More (SH-03) -Tekrama- sasia(MDR-045) Road (Total Length -13.90 km)
2022_CECOM_64532_1
RCD/GUMLA/1187/2022-23
Open Tender
Civil Works
540 days
Agharma More (SH-03) -Tekrama- sasia(MDR-045)
Please refer Tender documents.
4 documents required · 4 mandatory
₹10,000
E.E. RCD ROAD DIVISION GUMLA
₹41.3 L
Chief Engineer (Communication), RCD, Jharkhand, Ra
23 Feb 2023
2 Jan 2023
3 Feb 2023
2 Jan 2023
30 Jan 2023
10 Jan 2023
9 Jan 2023
Amount
Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, sapling and tress girth upto 300 mm, removal of stumps of tree cut earlier and disposal of unserviceable materials and stacking of sericeable material to be used of auctioned, up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150mm in thickness. Manual Means in area of light Jungle RCD SOR 2.03(i)A
Removal of stumps, roots, staking of serviceable material with all lifts up to a lead of 1000 metres and earth filling in the depression/ pit. Removal of stumps and roots including backfillinbg with suitable material to required compaction, Girth from 300mm to 600mm RCD SOR 2.01B(i)
Cutting of trees, excluding removal of stumps and roots of trees Cutting of trees stacking of serviceble material with all lifts and up to a lead of 1000 metres. Girth from 300mm to 600mm. RCD SOR 2.01A(i)
Removal of stumps, roots, staking of serviceable material with all lifts up to a lead of 1000 metres and earth filling in the depression/ pit. Removal of stumps and roots including backfillinbg with suitable material to required compaction, Girth from 600mm to 900mm RCD SOR 2.01B(ii)
Cutting of trees, excluding removal of stumps and roots of trees Cutting of trees stacking of serviceble material with all lifts and up to a lead of 1000 metres. Girth from 600mm to 900mm. RCD SOR 2.01A(ii)
Removal of stumps, roots, staking of serviceable material with all lifts up to a lead of 1000 metres and earth filling in the depression/ pit. Removal of stumps and roots including backfillinbg with suitable material to required compaction, Girth from 900mm to1800mm RCD SOR 2.01B(iii)
Cutting of trees, excluding removal of stumps and roots of trees Cutting of trees stacking of serviceble material with all lifts and up to a lead of 1000 metres. Girth from 900mm to 1800mm. RCD SOR 2.01A(iii)
Removal of stumps, roots, staking of serviceable material with all lifts up to a lead of 1000 metres and earth filling in the depression/ pit. Removal of stumps and roots including backfillinbg with suitable material to required compaction, Girth above 1800mm. RCD SOR 2.01B(iv)
Cutting of trees, excluding removal of stumps and roots of trees Cutting of trees stacking of serviceble material with all lifts and up to a lead of 1000 metres. Girth above 1800mm. RCD SOR 2.01A(iv)
Removal of telephone/ Electric Poles and Lines, Removal of telephone/ Electric poles including excavation and dismantling of foundation concrete and lines under the supervision of concerned department , disposal with all lifts and up to a lead of 1000 metres and stacking the serviceable and unserviceable material separately RCD SOR 2.14
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concree, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with allk lifts and lead of 1000 metres, Dismantling Brick/ tile work By Manual means, In cement mortar. RCD SOR 2.04(ii)B
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concree, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with allk lifts and lead of 1000 metres,Dismantling stone masonry, Rubble stone masonry in cement mortar. RCD SOR 2.04(iii)B
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concree, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with allk lifts and lead of 1000 metres,Cement concrete Grade M-15 & M-20 RCD SOR 2.04(i)B
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concree, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with allk lifts and lead of 1000 metres,By Mechanical means, Prestressed/ Reinforced cement concrete grade M-20 & above. RCD SOR 2.04(ii)B
Removing all type of Hume pipes and stacking within a lead of 1000 metres including Earthwork and Dismantling of Masonry Works. Above 600mm to 900mm dia. RCD SOR 2.04(ix)B
Dismantling of flexible pavements and disposal of dismantled materials upto a leadof 1000 metres, stacking serviceable and unserviceable materials separately, By Mechanical means, Bituminous courses. RCD SOR 2.05(ii)A
Dismantling of cement concrete pavement by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a alead of 1000 metres, stackiung serviceable and unserviceable materials separately RCD SOR 2.06
Excavation for road work in soil with hydraulic excavator including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and tranporting to the embankment location within all lifts and lead upto 1000 m Ordinary Soil RCD SOR 3.06
Construction of Embankment with Material Deposited from Roadway Cutting. Construction of Embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Table 300-2. Rate per cum after adding royalty@Rs 27.48/cum. RCD SOR 3.17
Construction of Embankment with approved material obtained from Borrow pits with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of Table 300-2. RCD SOR 3.16
Construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with front end loader at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401. Rate per cum for grading-V Material RCD SOR 4.10 B(v)
Wet Mix Macadam (Plant Mix Method) Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with grader in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. RCD SOR 4.14B
Prime Coat over WMM/WBM, Providing and applying primer coat with SS1 grade bitumen emulsion on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.70 kg/sqm using mechanical means. RCD SOR 5.01A
Tack Coat on Bituminous surfaces, Providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.20 kg per sqm on the prepared bituminous surface cleaned with mechanical broom. RCD SOR 5.02(i)
Tack Coat on Granular surfaces treated with primer, Providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.25 kg per sqm on the prepared bituminous surface cleaned with mechanical broom. RCD SOR 5.02(ii)
Dense graded Bituminous Macadam Grading-II with VG-30 Grade bulk Bitumen Providing and laying dense graded bituminous macadam with higher capacity batch type HMP using crushed aggregates of specified grading, premixed with bituminous binder @4.5 percent by weight of total mix and filler, transporting the hot mix to work site laying with a hydrostatic paver finisher with sensor control to the required grade level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORT&H specification clause no. 505 complete in all respects. RCD SOR 5.04A(B)
Providing and laying bituminous concrete with higher capacity batch type hot mix plant using crushed aggregates of specified grading, premixed with bituminous binder @5.4 percent of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment , rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORT&H specification clause no. 507 complete in all respects. Bituminous concrete Grading- II with VG-30 Grade Bulk Bitumen RCD SOR 5.05A(B)
Dry Lean Cement Concrete Sub- base, Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing. RCD SOR 6.01
Cement Concrete Pavement, Construction of un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with approve grade cement @ 400 kg per cum, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing RCD SOR 6.02
Retro-Reflectorised Traffic Signs, Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of class-B Type IV retro reflective sheeting fixed cover 2 mm thick aluminium sheeting vide clause 801.3, 3mm/4mm thick aluminium composite material sheet depending on the size of the sign fixed over back support frame of min 25 x 25 x 3 mm Angle mounted on a mild steel circular pipe 65 NB, 3.2 mm thickness firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. The sign shall be maintained as per section 12 of IRC 67. 90 cm equilateral triangle. RCD SOR 8.04 A(ii)
Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of class-B Type IV retro reflective sheeting fixed cover 2 mm thick aluminium sheeting vide clause 801.3, 3mm/4mm thick aluminium composite material sheet depending on the size of the sign fixed over back support frame of min 25 x 25 x 3 mm Angle mounted on a mild steel circular pipe 65 NB, 3.2 mm thickness firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. The sign shall be maintained as per section 12 of IRC 67.60cmx60cm Square RCD SOR 8.04 A(xiii)
Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of class-B Type IV retro reflective sheeting fixed cover 2 mm thick aluminium sheeting vide clause 801.3, 3mm/4mm thick aluminium composite material sheet depending on the size of the sign fixed over back support frame of min 25 x 25 x 3 mm Angle mounted on a mild steel circular pipe 65 NB, 3.2 mm thickness firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. The sign shall be maintained as per section 12 of IRC 67.80cmx60cm Rectangular RCD SOR 8.04 A(x)
Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of class-B Type IV retro reflective sheeting fixed cover 2 mm thick aluminium sheeting vide clause 801.3, 3mm/4mm thick aluminium composite material sheet depending on the size of the sign fixed over back support frame of min 25 x 25 x 3 mm Angle mounted on a mild steel circular pipe 65 NB, 3.2 mm thickness firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. The sign shall be maintained as per section 12 of IRC 67. 60cmx45.0cm rectangular RCD SOR 8.04 A(xii)
Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of class-B Type IV retro reflective sheeting fixed cover 2 mm thick aluminium sheeting vide clause 801.3, 3mm/4mm thick aluminium composite material sheet depending on the size of the sign fixed over back support frame of min 25 x 25 x 3 mm Angle mounted on a mild steel circular pipe 65 NB, 3.2 mm thickness firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. The sign shall be maintained as per section 12 of IRC 67.60cmCircular RCD SOR 8.04 A(viii)
Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of class-B Type IV retro reflective sheeting fixed cover 2 mm thick aluminium sheeting vide clause 801.3, 3mm/4mm thick aluminium composite material sheet depending on the size of the sign fixed over back support frame of min 25 x 25 x 3 mm Angle mounted on a mild steel circular pipe 65 NB, 3.2 mm thickness firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. The sign shall be maintained as per section 12 of IRC 67.90cm. High Octagonal RCD SOR 8.04 A(xv)
Direction and Place Identification Signs upto 0.9 sqm Size Board.(Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick or Aluminium composite material sheet with overall thickness of 4 mm with area not exceeding 0.9 sqm fixed over back support frame of min 35 x 35 x 3 mm Angle mounted on a mild steel circular pipe 65 NB, firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 x 45 x 60 cm, 60 cm below ground level as per approved drawing) RCD SOR 8.05
Printing New Letter and Figures of any Shade (Printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade) English and Roman (Hyphens and the like not to be measured and paid for) RCD SOR 8.03(ii)
Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface (Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.) RCD SOR 8.13
Kilometre Stone (Reinforced cement concrete M15grade kilometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc) 5th kilometre stone (precast) RCD SOR 8.14(i)
Kilometre Stone (Reinforced cement concrete M15grade kilometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc) Ordinary kilometer stone (precast) RCD SOR 8.14(ii)
Road Delineators (Supplying and installation of delineators (Road way indicators, hazard markers, object markers), 80-100 cm high above ground level, painted black and white in 15 cm wide strips, fitted with 80 x 100 mm rectangular or 75 mm dia circular reflectorised panels at the top, buried or pressed into the ground and conforming to IRC-79 and the drawings.) RCD SOR 8.15
Type - A, "W" : Metal Beam Crash Barrier (Providing and erecting a "W" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 811) RCD SOR 8.23A
Overhead Signs (Providing and erecting overhead signs with a corrosion resistant 2mm thick aluminium alloy sheet reflectorised with high intensity retro-reflective sheeting of encapsulated lense type with vertical and lateral clearance given in clause 802.2 and 802.3 and installed as per clause 802.7 over a designed support system of aluminium alloy or galvanised steel trestles and trusses of sections and type as per structural design requirements and approved plans & as per IRC: 67), Truss and Vertical Support. RCD SOR 8.07
Plain/Reinfoced Cement concrete in open foundation complete as per drwaing and technical specifications. RCC Grade M20, RCC Grade M20 using batching plant, transit mixture & Concrete pump. RCD SOR 12.08C Case I
Supplying, fitting and placing HYSD bar reinforcement in sub structure complete as per drawing and technical specifications RCD SOR 12.42
S/F/F of Retro Reflective sheeting of type-XI / DG3 in overhead Gantry including all cost of materials, labour and fixing charge complete as per IRC 67, 2012. ClauseNo.-6.7.4.1 NS
Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material. ordinary soil meach. means, depth upto 3m. RCD SOR 12.01I B(i)
Plain/Reinfoced Cement concrete in open foundation complete as per drwaing and technical specifications. PCC Grade M15 using batching plant & manual placing RCD SOR 12.08A Case I
Stone masonry work in cement mortar 1:3 in foundation complete as per drawing and technical specifications. Random Rubble masonry (coursed/uncoursed) RCD SOR 12.07 B
Stone masonry work in cement mortar 1:3 for substructure complete as per drawing and technical specifications Random Rubble Masonry (Coursed/uncoursed) RCD SOR 13.04A
Furnishing and Placing Reinforced/ Prestressed cement concrete in super-structure as per drawing and Technical Specification RCC Grade M25 Using Batching Plant, Transit Mixer and Concrete Pump Height upto 5m RCD SOR 14.01(B) Case I P
Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications RCD SOR 14.04
Plain/Reinforced cement concrete in sub-strucutre complete as per drawing and Technical specifications PCC Grade M20 Height upto 5m RCD SOR 13.05(B) P
Supplying, fitting and placing HYSD bar reinforcement in super-structure complete as per drawing and technical specifications. RCD SOR 14.02
Brick masonry work in 1:3 in superstructure complete excluding pointing and plastering, as per drawing and Technical Specifications RCD SOR 13.01
Plastering with cement mortar (1:3) on brick work in substructure as per technical specifications RCD SOR 13.03
Painting Two Coats on New Concrete Surfaces (Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces) RCD SOR 8.08
Providing and laying of filter media with granular materials/stones crushed aggregates satisfying the requirements laid down in clause 2504.2.2 of MoRT&H specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment , wing wall and return wall to the full height compacted to a firm condition complete as per drwaing and technical specification. RCD SOR 13.10
Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, covered with sealant complete as per drawing and technical specifications. RCD SOR 14.17 (iii)
Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6 per cent bitumen by weight RCD SOR 14.17 (iv)
Providing and laying Filter material underneath pitching in slopes complete as per drawing and Technical specification RCD SOR 16.05
Providing and laying pitching on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical specifications. Stone/Boulder RCD SOR 16.04A
Laying Reinforced cement concrete pipe NP4 / prestressed concrete pipe for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets . 1200 mm dia RCD SOR 9.04B
Levelling Course for Pile cap, Providing and laying of PCC M15 levelling course 100 mm thick below the pile cap. PCC Grade M15 using batching plant & manual placing. RCD SOR 12.41 Case II
Cement Concrete for Reinforced Concrete in Pile Cap complete as per Drawing and Technical Specification, RCC Grade M30, RCC Grade M30 using batching plant & manual placing. RCD SOR 12.40 C Case II
Driven cast-in-place vertical M35 grade R.C.C. Pile excluding Reinforcement complete as per Drawing and & Technical Specification Pile Dia 1200mm RCD SOR 12.25
Supplying, Fitting and Placing un-coated HYSD bar Reinforcement in Foundation complete as per Drawing and Technical Specifications. RCD SOR 12.42
Confirmatry, boring through core drilling of BX (41mm to 59mm) size by rotary core drilling machine upto 20.0 M depth in all kinds of hard rock including finishing maintenance of core (minimum 80% core recovery in hard rock is essential and sluge for foundation exploration complete as per specification and direction of E/I. L.S.
Plain/Reinforced cement concrete in sub-strucutre complete as per drawing and Technical specifications, RCC Grade M30, Height upto 5m, RCC Grade M30 using batching plant, transit mixer & concrete pump. RCD SOR 13.05 (G) P
Back filling behind abutment, wing wall, return wall complete as per drawing and technical specifications, Granular Material. RCD SOR 13.09A
Reinforced cement concrete approach slab including reinforcement and formwork complete as per drawing and Technical specification RCD SOR 14.11
Providing weep holes in Brick masonry/ Plain/Reinforced concrete abutment , wing wall/ returen wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V:20 H towards drawing face. Complete as per drawing and technical specifications. RCD SOR 13.08
Supplying, fitting and placing HYSD bar reinforcement in sub structure complete as per drawing and technical specifications RCD SOR 13.06
Furnishing and Placing Reinforced/ Prestressed cement concrete in super-structure as per drawing and Technical Specification, RCC Grade M30 Using Batching Plant,Transite Mixer and Concrete Pump. Height 5m to 10m. RCD SOR 14.01C CaseI (q)
Reinforced Cement Concrete Crash Barrier, Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with Reinforced Cement Concrete with HYSD reinforcement conforming to MoRT&H specification and as per details given IRC-5 (Fig.-5, b) including dowel bars 25 mm dia, 450 mm long at expansion joints filled with pre-moulded asphalt filler board etc., as per approved drawing and at locations directed by the Engineer, all as specified. (Area- 0.243 sqm./meter, single face), M 25 grade concrete. RCD SOR 8.22A (i)
Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70 mm, complete as per approved drawings and standard specifications to be installed by the manufacturer/supplier or their authorised representative ensuring compliance to the manufacturer's instructions for installation. RCD SOR 14.21
Drainage spouts complete as per Drawing and Technical Specifications. RCD SOR 14.09
Supplying , fitting and fixing in position true to line and level elastomeric bearing conforming to IRC:83 (Part-II) section IX and clause 2005 of Mort&H specification complete including all accessories as per drwaing and technical specifications RCD SOR 13.16
Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 sqm. RCD SOR 14.16
Providing and laying pitching on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical specifications. Stone Boulder RCD SOR 16.01
Providing and laying Filter material underneath pitching in slopes complete as per drawing and Technical specification RCD SOR 16.05
Add 18% GST :
Add 1% Labour Cess:
M/s. N. C. Nahar
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid