Loading…
Loading…
Tender Value
₹19.6 L
EMD Value
₹39,100
Closing Date
12 Oct 2026, 1:00 pm
Executive Engineer Paschim Med. Elecl. Div. PWDte.
Office of the Executive Engineer, Paschim Medinipur Electrical Division, P.W.Dte., Midnapore, Paschim Medinipur.
Replacement of old and damaged AHU Type AC Machine installed at Hybrid CCU of Kharagpur SD Hospital, Paschim Medinipur.
2026_WBPWD_5074758_1
WBPWD/EE/PMED/NIT-03/e-T /2026-2027
Open Tender
ELECTRICAL WORKS ORG
Percentage
21 days
Kharagpur S. D. Hospital, Paschim Medinipur.
Please refer Tender documents.
3 documents required · 3 mandatory
₹39,100
Yes
23 Sept 2026
23 Sept 2026
14 Oct 2026
23 Sept 2026
12 Oct 2026
23 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supplying, Installation, Testing and Commissioning of air cooled ducted split type air conditioning machine with each having a capacity and details as mentioned below suitable for operation on R 32/R-410A /R-407 Green refrigerant comprising of Scroll type compressor hermatically sealed complete with automatic capacity, safety switches, lubrication system with min 5 year (OEM) warranty for both compressor and Printed Circuit Board (PCB), Suitable capacity squirrel cage induction motor having class 'B' insulation suitable for operation on 415 + 10% volts, 50 Hz, A.C. supply for Blower motor, Necessary drive arrangement for blower motor, Matching Air cooled condenser with necessary fittings for refrigerant piping connections, necessary structural support for mounting condensers, Microprocessor based control panel complete with accessories, machine Isolation / disconnect switch, valves and accessories to inter connect compressor and condenser including pressure testing, vacuum. Necessary starters suitable for Indoor & outdoor unit complete with O/L, U/V, phase reversal protection, single phase preventors i/c copper conductor control and power cable and drain pipe of suitable size and length etc complete as required. The total cooling capacity/heating capacity of tested unit shall have a capacity as per relevant IS code. The lab testing reports as per IS: 8148 shall be submitted from National Accreditation Board for Testing and Calibration Laboratories (NABL) accredited as per ISO/International Electrotechnical Commission (IEC) 17025 standards / Central Power Research Institute (CPRI)/Electrical Research and Development Association (ERDA)with Original Equipment Manufacturer (OEM) etc. complete as per CPWD specification as required. [DSR(E&M)2025/P243/32.3] | |||||
| 1.01 | 8.5 TR (3.2 EER) [Non-Inverter] | 5 | Each | 1,64,444 | ₹8,22,220 |
| 2Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : [DSR(E&M)2025/P240/31.14] | |||||
| 2.01 | 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm | 70 | Mtr | 615 | ₹43,050 |
| 2.02 | 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm | 70 | Mtr | 1,157 | ₹80,990 |
| 3Supplying, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/ round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, bends, transitions, reducers, end caps, collars etc as required complete in all respect in confirmation with IS : 655 and approved drawings and specifications of following sheet thickness complete as required. [DSR(E&M)2025/P228/30.12.2] | |||||
| 3.01 | Thickness 0.63 mm sheet | 140 | m² | 1,213 | ₹1,69,820 |
| 3.02 | Thickness 0.80 mm sheet | 40 | m² | 1,415 | ₹56,600 |
| 4Supplying and fixing of following thickness duly laminated aluminium foil of mat finish closed cell Nitrile rubber (Class "O") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. [DSR(E&M)2025/P230/30.23] | |||||
| 4.01 | 19mm | 140 | m² | 810 | ₹1,13,400 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.60 MB
BOQ_5162623.xls
BOQ • 0.33 MB
2911.pdf
Tender Documents • 0.50 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .