Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.6 CrAccepted-AOC | ₹27.6 Cr | L1 | Accepted-AOC Accepted
being L1 |
| 2 | L2₹28.4 CrRejected-Finance 216 C SIVA COLONY MAYO LINK ROAD AJMER RAJASTHAN 305007 | AJMER | RAJASTHAN | 305007 | ₹28.4 Cr | L2 | Rejected-Finance REJECTED BEING L2 |
| 3 | L3₹28.6 CrRejected-Finance 17 1624A MUMDAMVELI KOCHI 682 507 | ERNAKULAM | KERALA | 682507 | ₹28.6 Cr | L3 | Rejected-Finance REJECTED BEING L3 |
| 4 | L4₹30.2 CrRejected-Finance MANATHA ENCLAVE 3RD FLOOR OLIMUGAL KAKKANAD P O KOCHI 682 030 KERALA | ERNAKULAM | KERALA | 682030 | ₹30.2 Cr | L4 | Rejected-Finance REJECTED BEING L4 |
| 5 | L5₹30.9 CrRejected-Finance | ₹30.9 Cr | L5 | Rejected-Finance REJECTED BEING L5 |
Tender Value
₹29.5 Cr
EMD Value
₹15 L
Closing Date
12 Oct 2020, 6:00 pmClosed
CE NW KOCHI
CE NW KOCHI KATARIBAGH NAVAL BASE P O KOCHI 682004
DEMOLITION AND RECONSTRUCTION OF T39 HANGER AND LEAN AREA AT NAY KOCHI
2020_MES_361255_1
890951/E8
Open Tender
Civil Works
700 days
KOCHI
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹3,000
Yes
GE P NW KOCHI
₹15 L
Yes
23 Feb 2021
15 Jul 2020
15 Oct 2020
15 Jul 2020
12 Oct 2020
26 Sept 2020
5 Aug 2020 - 10 Aug 2020
Amount
Total amount of Sch 'A' part-IA (Buildings/ Structures (Lean to Hanger))
Total amount of Sch 'A' part-IB (Hanger Incl Floor)
Total amount of Sch 'A' part-II (Excavation, earthwork, Site clearance & Develoment)
Total amount of Sch 'A' part-III (Internal Water Supply)
Total amount of Sch 'A' part-IV (Internal Electrification for lean Area & Hanger)
Total amount of Sch 'A' part-V (External Water Supply)
Total amount of Sch 'A' part-VI (External Electrification)
Total amount of Sch 'A' part-VII (Lightning Protection)
Total amount of Sch 'A' part-VIII (Road/Path &Culvert)
Total amount of Sch 'A' part- IX (Sewage Disposal)
Total amount of Sch 'A' part- X (Area Drainage)
Total amount of Sch 'A' part- XI (Fire detection and alarm system)
Total amount of Sch 'A' part- XII (Roof top SPV Plant)
SCH 'A' PART- XIV (MISCELLANEOUS: Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Boring for cast-in-situ bored piles of 600mm dia to any depth through any type of soil/strata by DMC method using bentonite slurry including removal of bored materials to place outside MD land all as specified and as directed Note:- The rate shall include mobilisation, erection, dismantling and demobilisation of equipment for pile boring including all labours and material. Nothing extra shall be payable for mobilisation of equipment seperately.
RCC with ready mix concrete (RMC) M30 grade as per IS-456 with using 20mm graded stone aggregate in cast in situ bored pile of any depth/any sections complete all as specified and as shown on drg as in bored pile including non destructive integrity test on all pile as per IS 2911 part IV.(Note:-(i)The unit rate quoted under this item is deemed to be inclusive of charges for non destructive test (ii)Reinforcement will be measured and paid separately under relevant items
RCC with ready mix concrete(RMC) M30 grade in pile cap , grade beam & tie beam complete all as specified and shown on drg. Note:- Reinforcement will be measured and paid separately under relevant items
CRS/HCRS/CRM TMT bars in reinforcement 10mm dia and over including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with 0.9mm dia MS wire annealed or welding so as to secure the bar firmly in position/required shape complete all as specified and shown on drgs as in Piles.
CRS/HCRS/CRM TMT bars in reinforcement 10mm dia and over including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with 0.9mm dia MS wire annealed or welding so as to secure the bar firmly in position/required shape complete all as specified and shown on drgs as in grade beams, tie beam, slab and pile caps.
CRS/HCRS/CRM TMT bars 5mm to 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality complete all as specified and shown on drgs as in Helicals for piles.
CRS/HCRS/CRM TMT bars 5mm to 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality complete all as specified and shown on drgs as in stirrups of grade beams.
CRS/HCRS/CRM TMT bars in reinforcement 10mm dia and over for Ring/Stiffener for piles including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with 0.9mm dia MS wire annealed or welding so as to secure the bar firmly in position/required shape complete all as specified and shown on drgs .
PCC (1:4:8) type D2 using 40mm graded stone aggregate for concrete layer below pile caps/grade beams and foundation complete all as specified and shown on drgs.
Providing testing equipment & load and testing of 600mm dia bored pile (Initial Load test) all as per IS including removing the testing equipments from site after testing is completed all as specified and directed.
Providing testing equipment & load and testing of 600mm dia pile (Routine Load test) all as per IS including removing the testing equipments from site after testing is completed all as specified and directed.
Conducting standard penetration test all as per IS-2131 at levels and locations as directed for 600mm dia cast in situ bored piles all as specified and as directed.
Excavation in trenches not exceeding not exc 1.5 wide and not exc 1.5m deep, not exc 10 sq m on plan and getting out in soft/loose soil complete all as specified and directed.Note:- Rate shall be include for excavations in any type of soil including bailing out/pumping out water on account of spring/rain or any other causes using any method as required and as directed by Engineer-in-Charge for pile caps/grade beam.
Excavation in trenches not exceeding not exc 1.5 wide and exc 1.5m and not exc 3m deep, not exc 10 sq m on plan and getting out in soft/loose soil complete all as specified and directed.Note:- Rate shall be include for excavations in any type of soil including bailing out/pumping out water on account of spring/rain or any other causes using any method as required and as directed by Engineer-in-Charge for pile caps/grade beam.
Excavation over areas not exceeding not exc 1.5 m deep and getting out in soft/loose soil complete all as specified and directed.
Excavation over areas exceeding not exc 1.5 m and not exc 3m deep and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed.
Removing excavated material to a distance exceeding 1.5Km but not exceeding 5Km and deposited where directed at a level not exceeding 1.5meter above the starting point complete all as specified and directed
Formwork to sides of pile caps , grade beams rough finished surface of concrete flat all as specified .
Material and labour for stone dust under floor or in foundation including spreading, levelling, watering and well ramming in layers not exceeding 25cm in depth all as specified and as directed.
INTERNAL ELECTRIFICATION FOR LEAN AREA AND HANGER:
Material and Labour for point wiring using approved colour coding as per IS complete using 1.5 Sqmm PVC insulated unsheathed copper conductor, multi stranded cable (HF & FR) upto and incl working voltage 1100 volts grade, ISI marked, drawn through and including heavy duty PVC concealed conduit including all accessories as bend, tee, junction boxes, elbows etc including modular GI flush box of suitable size with inner and outer white plastic plate (same make of approved switch and socket) and unsheathed copper conductor size 1.5 Sqmm Cross sectional area multistranded cable (HF & FR) earth continuity wire to common earth and all other metal parts with earth dolly for the following:-. Note: Switch and socket shall be measured and paid for seperately
One light/ceiling fan/exhaust fan point controlled by one 5/6 Amps, one way switch.
One light point controlled by two nos 5/6 Amps, two way switch.
One 3/5 pin socket outlet 5 Amps on Independent board.
Material and Labour for point wiring using approved colour coding as per IS complete using 2.5 Sqmm PVC insulated unsheathed copper conductor, multi stranded cable (HF & FR) upto and incl working voltage 1100 volts grade, ISI marked, drawn through and including heavy duty PVC concealed conduit including all accessories as bend, tee, junction boxes, elbows etc including modular GI flush box of suitable size with inner and outer white plastic plate (same make of approved switch and socket) and unsheathed copper conductor size 2.5 Sqmm Cross sectional area multistranded cable (HF & FR) earth continuity wire to common earth and all other metal parts with earth dolly for one 3/5 pin socket outlet 15/16 Amps independent complete all as specified and as directed. Note: Switch and socket shall be measured and paid for seperately
Demolition of existing hangar of T-39 including foundation structural steel for gate wall, wall sheets, roof sheets and connected electrical/water supply lines, fitting/fixtures, brick masonry wall ceiling board and taking down for door/windows etc complete all as specified.
Supply and fixing ceiling fan 1200mm sweep copper wound having minimum service value of 4cum/min/W and min air delivery 210cum/min BEE approved including fixing of down rod and connecting up complete with and including three core flexible PVC insulated multi stranded copper conductor cable of size 0.5 Sq mm from ceiling rose/ connector to fan complete all as specified and as directed.
Supply and fix Exhaust fan 250 mm sweep 230 Volts AC 50 Hz PVC body with copper wound motors and PVC louvers, including connecting up from ceiling rose with 3 core flexible copper cable, PVC sheathed of size 1.5 sqmm complete all as specified and as directed. Note : Make for items 39 & 40 shall be either of Almonard/ Crompton/Khaithan
Supply and fix 20W LED Batten light fitting with extruded aluminium housing 4 feet long with all accessories and integrated electronic driver complete all as specified and as directed. Make : Philips model Smart Bright Cat part No. BN021C LED20S PSU CW GR S2 or eqvt in /Wipro/ Osram/GE
Supply and fix 32W LED square shaped light fitting general purpose, surface type with low height, CRCA housing and high transmitivity diffuser and electronic drive complete all as specified and as directed. Make : Philips model Cirrus Surface Cat part No. SM65C LED32-6500 PSU OD GR or eqvt in /Wipro/ Osram/GE
Supply and fix surface down light fitting LED 7W complete all as specified and as directed. Make : Philips model SLEEK Surface Downlight Cat part No. SM250C led7s-6500 PSU WH or eqvt in /Wipro/ Osram/GE
Supply and fix LED bulk head light fitting with IP 65 Protection, and IK08 impact resistace, suitable for surface and wall mounting complete all as specified and as directed.. . Make:Philips model Vistaglow Cat part No. WT140W LED7S CW PSU S1PC or eqvt in /Wipro/ Osram/GE
Supply and fix LED street light fitting with pressure die cast aluminium housing and acrylic cover as diffuser, having IP 66 protection of 30 Watt complete including fixing with GI Bracket made of 43mm outer dia GI Pipe including fixing clamps etc and wiring from junction box/ceiling rose with 3 core flexible copper wire, 1.5 sqmm complete all as specified and as directed. Make : Philips model Vistaglow Cat part No. BRP046 LED30 CW MR S1 PSU GR or eqvt in /Wipro/ Osram/GE
Supply and fixing distribution board in sheet metal enclosure, powder coated, factory made, IP 43 protection, double door type TPN 4 way with 200 Amps, 415 Volt rated bus bar neutral and earth connected bars complete all as specified and as directed
Supply and fixing distribution board in sheet metal enclosure, powder coated, factory made, IP 43 protection, double door type SPN 12 way with 200 Amps, 240 Volt rated bus bar neutral and earth connected bars complete all as specified and as directed.
Supply and fix MCB "C" series, TPN, 63 Amps, 415V, 50 HZ, 10 KA complete all as specified and directed.
Supply and fix MCB "C" series, SP, 06 to 32 Amps, 240V, 50 HZ, 10 KA complete all as specified and directed.
Supply and fix MCB "C" series, SPN, 40 Amps, 240V, 50 HZ, 10 KA complete all as specified and directed. Note : i) Make for items 46 to 50 shall be either of Havells/L & T/Legrand/ABB/ Siemens/Schneider ii) DB, MCB & MCCBs of same make shall be used.
Material and labour for Sub main wiring using 4 runs of 10Sqmm single core PVC insulated cable (HF&FR) copper conductor multi stranded and 2 runs of 10 sqmm copper conductor insulated unsheathed cable (HF&FR) using as earth continuity connected to earth dolly drawn through and including suitable size PVC conduit 32mm dia complete all as specified and directed. Note- One run of 32mm dia PVC conduit and 6 runs of 10 sqmm PVC copper wire shall be measured and paid as one unit.
Material and labour for Sub main wiring using 2 runs of 6 Sqmm single core PVC insulated cable (HF&FR) copper conductor multi stranded and one run of 6 sqmm copper conductor insulated unsheathed cable (HF&FR) using as earth continuity connected to earth dolly drawn through and including suitable size PVC conduit 25mm dia complete all as specified and directed. Note- One run of 25mm dia PVC conduit and 3 runs of 6 Sqmm PVC copper wire shall be measured and paid as one unit.
Material and labour for Sub main wiring using 2 runs of 2.5Sqmm single core PVC insulated cable FRLS copper conductor multi stranded and one run of 2.5 sqmm copper conductor insulated, unsheathed cable FRLS using as earth continuity connected to earth dolly drawn through and including suitable size stove enamelled steel conduit 20mm dia grade ISI marked with accessories fixed on steel structures like pipes, angle iron, channels etc with suitable clamps/bracket lights for lighting circuits complete all as specified and directed. Note- One run of 20mm dia steel conduit and 3 runs of 2.5 sqmm PVC copper wire shall be measured and paid as one unit.
Supply and fix SPN enclosure with a 2 pin and earth plug and socket including provision of one MCB SP, 20A, 240 Volts complete all as specified and as directed.
Supply and fixing distribution board in sheet metal enclosure, powder coated, factory made, IP 43 protection, double door type SPN 4 way with 200 Amps, 240 Volt rated bus bar neutral and earth connected bars complete all as specified and as directed
Supply and fix energy saving environment friendly & robust high bay / medium bay LED IP 66 luminarie with high efficiency PDC housing suitable for industrial application with efficacy of 150Lm/w LED high bay light fitting 100W with and including fixing acessories to fix the fitting suspended/ fixed on roof struss complete all as sprcified and directed by Engr in Charge. Make: Havells Model No SAUCER NEXTGEN HIGHBAY Cat part No. SAUCERGENXPROHBP100WLED757P60DBOLTG or equivalent in Bajaj/ Philips/ Wipro etc.
Supply and fix heavy duty Air circulators, AC 230V, 180/200W, single phase, oscillating type, 600mm(24") sweep 1440 RPM suitable for fixing to structural column of hangar including suitable clamps and fixing arrangements complete all as sprcified and directed by Engr in Charge. Make : Almonard/Crompton/Khaitan
Supply and fix in replacement of Distribution board (DB) made out of sheet metal enclosure (CRCA sheet), dust and vermin proof, V TPN 8 way with 200 Amps rated copper bus bar double door protection, neutral bar, earth bar, 415 volts, suitable for MCCB FP as incomer flush to wall complete all as specified and directed.
Supply and fix MCCB 4 Pole, current rating 100 Amps, breaking capacity 16 KA, 415 V, 50 HZ fixed with thermal and magnetic settings complete all as specified and directed
Supply and fix MCB "C" series, TP, 63 Amps, 415V, 50 HZ, 10 KA complete all as specified and directed.
Supply and fixing in repairs Angular stop cock with wall flange of size 15mm and fixed complete all as specified and as directed. Make-Jauqar. Cat No.FLR-5053N or equivalent in Parryware/Hindware
Supply and fix health faucet/ hand shower with 8mm dia, wall hook and easy flexible tube in crome finish 1.5m long with nuts complete all as specified and as directed. Make: Jaguar cat part No ALD573 and SHA571 or equivalent as per approved makes.
Supply and fix over head shower rose 100mm dia round shape single flow ABS body chrome plated wirh grey face plate and Rubi/ cleaning system and shower arm casted 120mm long heavy body round shape for wall mounted shower with wall flange complete all as specified and as directed. Make: Jaguar cat part No OHS1989 and SHA-487 or equivalent as per approved makes.
Supply and fix stop cock long body combination of exposed part kit of concealed stop cock with fitting sleave, operating knob, adjustable wall flange and regular body concealed stop cock suitable for 15mm pipe line with protection cap complete all as specified and as directed. Make: Jaguar cat part No CQT-23082K and ALD083 or equivalent as per approved makes.
AIR CONDITIONING:
Supply and fix testing and commisioning high wall mounted inverter type air cooled split unit air conditioner electric driven, single phase of capacity of 1.5 TR, BEE 5 star rated and with and including Out door units mounted with bracket fixed on wall/ metalic surfaces with suitable size and suction & discharge copper tubes with insulations from indoor units to outdoor units complete with refrigerant as required to maintain required pressure standing to achieve temperature with and including modular switch and socket, modular MCBs 20 Amp, modular terminal boxes and base plate etc complete all as specified and directed.
Supply and fix testing and commisioning high wall mounted inverter type air cooled split unit air conditioner electric driven, single phase of capacity of 2 TR, BEE 5 star rated and with and including Out door units mounted on brackets fixed on wall/ metalic surfaces of suitable size and suction & discharge line copper tubes with insulations from indoor units to outdoor units complete with refrigerant as to maintain required pressure complete all as specified and as directed.
Supply and fix Voltage stabiliser for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output viltage stabilized at 230 V with accuracy ± 2.5% and of capacity 4 KVA for 1.5 TR split ACs complete all as specified and as directed.
Supply and fix Voltage stabiliser for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output viltage stabilized at 230 V with accuracy ± 2.5% and of capacity 5 KVA for 2 TR split ACs complete all as specified and as directed.
Material and Labour for provision of drain pipe of size 20mm dia with low density polyethylene pipes (LDPE) of pressure rating 6 Kgf/cm2 fixed complete to walls/ceilings or in floors or at any other indicated situation etc complete all as specified and as directed.
EOT CRANE:
Design (Approved by Chartered Engineer), Fabricate, Supply, Install, Testing and Commisioning of 3 Ton EOT Crane comprising of following and conforming to IS 3177 -1999 amended up to date. Type: Double guirder EOT crane Capacity: 3 MT Span: As shown in drawings Long Travel: 59 Mtr Hook Height: 5.2metre Service class: Indoor Class II Oerations: Through pendant push button from floor. Speed: Hoisting 3 m/min, CT/LT- 10 m/min, VFD for Hoisting , CT & LT 10% of main speed Drive: VVVF Brakes: EM type for all motions. Hook: Forged steel with latch lock Wheel: EN-8 or forged steel material. Covering with Brass/ gun metal for avoiding sparking Electric Motor: All motors for LT, CT, & hoist shall be as per manufacturers design. Gear box: Helical type for all motions. Closed dust proof construction Panel Box: M.S. Fabricated with all required MCB, controls, & limit Switches. Flame proof Limit switches: Rotary type for Hoisting & Lever type for CT & LT. Bridge: Fabricated from MS plates box type construction walking platform area with railing. End carriage with LT Drive. Crane will be golden yellow painted. One no ladder & spot light two nos. will be provided.Make:-Safex/Dinesh/Pioneer
Note: Rate inclusive of Longitudinal travel sq bar rail, DSL for LT and CT, Crane bridge and crab complete with panel and other electric switches required for smooth function.
FIRE DETECTION AND ALARM SYSTEM:
Supply, installation, testing & commissioning of networkable 2 Loop Micro processor based 2 wire fault tolerant loop with optional redunadant network module, each loop shall have the cpability of connecting 126 devices. The fire alarm control panel shall have built in degarde mode function. The panel should have in built TCP/IP communication for Panel Program and Remote Monitoring option through LAN or WAN communication. The panel shall be able to give location of all fire and more fire /fault and isolation conditions of addressable units via the address codes. The panel shall have the capacity of storing upto 2000 events. Further, the panel must be able to automatically switch ON /OFF respective control module when ever any alarm is triggered. The panel should have inbuilt common Alarm, Fault and monitored sounder output. The panel shall have a 8x40 characters LCD display with resolution of 256 X 112 pixels, and analog output, external/inbuilt printer to log all fire or fault events complete in all respects. The panel should have protection caregory of IP30. Also the panel should have the option to operate in manned and unmanned mode. The Panel shall have 99 Zones with Individual LED Indicators or with in the Loop mimic driver for 96 LED indicators. The panel shall have a built in power supply and battery charger along with maintenance free 24 AH, 2 x 12 volt SMF Lead acid batteries capable of running for a minimum of 24 hours with battery charger complete all as required and as per specifications and dully ISI marked.
Supply, installation, testing and commissioning of Analog addressable type Active Loop Repeater (Loop power/external power) Fire terminal, Backlit LCD Display 6 x 40 characters display, having Controls for Reset, Mute, Accept, Silence alarms and Self Test with programmable free Keys and Duly approved by UL/FM (repeater panel should be placed in Guruda Fire Station) complete all as required and as per specifications and dully ISI marked.
Supply and installation, testing and commissioning of intelligent addressable manual call point with inbuilt turbo isolator suitable for flush or surface mounting, call point shall include test key feature without removing the glass. Also should have protection category of IP44 and extra accessories complete all as required and as per specifications and dully ISI marked.
Supply and installation, testing and commissioning of addressable sounder complete all as required and as per specifications and dully ISI marked.
Supply and fix addressable type multisensor detector with heat and smoke combination complete all as required and as per specifications and dully ISI marked.
Visual indication: Green LED : Power Red LED : Alarm Yellow LED : Fault Temperature range : Operating 100o Filed of View FS24X: -40oF to +185oF (-40oC to +85oC); 90o Field of View FS24X: -60oC to +85oC (-76o F to +185oF) Storage: -67oF to + 230oF (-55oC to +110oC) Humidity range: 5 to 98% relative humidity, non-condensing Vibration : Meets or exceeds MilSpec 840C Method 514.2, Curve AW12 Wiring: 14 AWG to 22 AWG : Sheilded cable recommended Conduit entries: Standard : Two M25 or two ¾" NPT Enclosure materials : Copper-free powder coated aluminum Enclosure type: IP66 and NEMA 4 & 4X Certifications: FM : Class I, Div. 1&2, Groups B, C & D, Class II, Div. 1&2 Groups E, F & G; Class III ATEX/IECEx : Ex II 2 G Ex db IIC T4 (Ta: -60 to + 110oC), T5 (Ta: -60 to +75oC), T6 (Ta -60 to +60oC), II 2 D Ex tb IIIC T135oC (FS24X-9, 90o Field of Ex II 2 G Ex db IIC T4 (Ta: -40 to + 110oC), T5(Ta: -40 to +75oC), T6 (Ta -40 to +60oC), II 2 D Ex tb IIIC T135oC (FS24X-2, 110o Field of View) CE: Complies with EN6100-6-4 & EN50130-4 INMETRO CU-TR SIL Rating: FMEDA available on request. EN54-10: FS24X-9 certified 1175a/02 (LPCB); CPR 0832-CPR-F0516 Note for Item No 73 to 80:- Make :-Honeywell/Siemens/Firex
Supply, installation, testing and commissioning of 2 x 1.5 Sqmm copper conductor armoured HFFR cable with aluminium sheilding accessories including glanding complete all as required and as per specifications.
Supply and fix Remote response indicators complete all as required and as per specifications.
Taking down air circulator and depositing to MES store yard for further disposal complete all as specified and as directed by the Engineer-in-Charge.
AVIATION OBSTRUCTION LIGHT:
Supply and fix LED aviation obstruction light single phase 230 Volt 50Hz with and including necessary fixing arrangements such as MS angle frame work duly fabricated and bend to shape and painting with two coats of synthetic enamel paint over a coat of red oxide primer and fixing it on position as indicated at site complete all as specified and directed. Make: Bajaj Cat No. BGAV 302 LED
Supply and fixing, testing comissioning XLPE insulated screened PVC bedded galvanised steel strip or wire armoured power cable (Heavy duty) 1100 V grade with stranded aluminium conductor of size 2 core 4 Sqmm on poles /walls as cable for aviation obstruction light all as specified and directed.
Supply and fix MCB distribution board SP 2 way, single phase 240 Volt rated without bus bar complete all as specified and as directed
Supply and fix analog time switch (with battery backup) 1P module, 24 hours program, programmable every 15 min, backup of 100 hours, current capacity 16A with 1 changeover complete all as specified and as directed
Supply and fix 6 Amps SP MCB 'C' series 240V including connections complete all as directed.
WATER COOLERS:
Supply and fix Ozone based water cooler most superior water purification technology ozonisation microprocessor controlled electronic system to ensure the precise operation and ABC (Acrylonitrile Butadiene styrene) material HIMA 7N HC on line purifier cum normal hot and cold dispenser 125Ltr/Hr with storage capacity of 180 litres complete all as specified and as directed.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170V to 250V with output voltage stabilized at 230V with accuracy of ± 2.5% and of capacity 4 KVA complete all as specified and as directed.
EXTERNAL WATER SUPPLY:
Construction of 200mm thick PCC solid block wall masonry valve chamber of size 900x900x900mm built in CM 1:6 with 100mm thick PCC foundation 1:4:8 type D2, coping 50mm thick finished even and smooth,rendering 10mm thick in cement mortar (1:4),finished fair and even externally including excavation earth work in any strata, 6mm thick MS sheet cover fixed on angle iron frame 25x4mm embedded in PCC coping with locking arrangement and mild steel hold fast, mild steel handles and painting to steel surface with two coats of black bituminous paint over one coat of red oxide primer etc.complete all as specified and as directed.
Supply, installation, testing and commissioning of manufacturer’s factory assembled and tested electric driven Multistage mono block centrifugal pump sets of capable of delivering 4.2 LPS at 60 Meter head coupled with three phase 415 volt 3000 RPM complete of Cat Part No KDT 864+ with HP not less than 5.5 Hp/7.5 KW and 65mm Suction and 50mm delivery of Make Kirloskar Brothers. The work also includes the followings:- (a) Material & Labour for lowering of GI suction pipe flanged type heavy grade welded with flange of dia not less than the dia suitble to match the suction of pumps from foot valve at suction pit to pumps. Note for sub item (a): The cost of foot valve is deemed to be included in unit rate. (b) Material & Labour for of GI dilvery pipe flanged type heavy grade welded with flange of dia not less than the dia suitable to match the pumps from Pump butterfly valve and from butterfly valve to NRV. (d) Material & Labour for MS 'C' chanel for clamp made out of MS flat 100x12 mm for lowering/installation of pump set complete- 01 Nos (e) Supplying, fixing and testing of Brass reflux valve (NRV) of suitable dia flanged joint complete with nuts, bolts and washers complete all as specified. (f) Supply and fixing of slim seal butterfly valve with iron wheel head both ends flanged for iron pipe and fixed complete with nuts, bolts and washers complete all as specified.
(g) Pressure gauge diaphragm type glyserene filled to read water pressure up to 75 Kg/Cm2-1 No. (h) Material & Labour for air release valve 15mm. (j) Priming arrangements using 25mm CPVC pipe up to 6m in length including acessories. (k) Material & Labour for ball valve 25mm bore (l) Priming tank using PVC tank of capacity 250 Ltrs with over flow pipes -01 No (m) The pump set is to be installed in existing pump house as inducated at site.
EXTERNAL ELECTRIFICATION:
Supply and laying UG cable XLPE insulated, screened, PVC bedded, galvanised steel wire/strip armoured electric power cables, heavy duty LT 1100 Volt grade, with aluminium conductor of size 240 Sqmm 3.5 core including cable glands, aluminium lugs, nuts, bolts, washers etc and connections laid in trenches/ fixing on wall/ poles/ passing through pipes complete all as specified and as directed. NOTE: Excavation and earth work shall be measured and paid separately
All as per item No 97 above, but for 150 Sqmm x 3.5 Core
All as per item No.97 above, but for 16 Sqmm x 2 Core
All as per item No.97 above, but for 16 Sqmm x 4 Core (From LT Panel to Building DBs)
All as per item No.97 above, but for 35 Sqmm x 3.5 Core (From LT Panel to Building DBs)
Supply, spreading and levelling riddled soil as earth cushioning to UG cable by using IS seive to seperate the composite/roots etc and refilling spreading in trenches as cushioning and rammed down to form a solid bed all as specified and directed at site. Note:- Punned thickness shall be measured and paid.
Supply, installation, testing and commissioning of CPRI approved Factory made and tested indoor and cubical type double door Panel board suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with air insulated PVC sleeved with heat shrink of colour code on copper bus bar of rating 600 Amps for phases and 300 Amps for neutral fixed on epoxy insulators. The panel shall be weather proof, dust and vermin proof IP-54 class protection and fabricated out of 2mm thick CRCA sheet duly powder coated after seven tank process and pedestal duly fabricated out ofequal angle of size 50 x 50 x 6 mm thick MS angle iron frame work duly embedded in PCC 1:3:6 with suitable space/ grooves for cable entry and exit. The panel shall be both front and rear opening, centre opening doors on hinges with industrial type locking arrangments type adequate space all around accessories complete with multilayer layer chambers to accomodate each LT switchgears and measuring instruments as furnished below and including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size as per standard is practices and comprising of followings accessories.
INCOMINGS: (a) MCCB 415 Volts, 300 Amp rating, 4 Pole microprocessor based (Service Breaking Capacity 40kA Icu=100 % Ics- 01 No (b) Digital volt meter 0-500 Volts-01 (c) Digital Ampere meter 0-300 Amps with and including CTs OUTGOINGS: (a) MCCB 415 Volts, 100 Amp rating, 4 Pole Thermal magnetic relay (Service Breaking Capacity 18 kA) Icu=100 % Ics- 02 No (b) MCCB 415 Volts, 63 Amp rating, 4 Pole Thermal magnetic relay (Service Breaking Capacity 18 kA) Icu=100 % Ics- 04 No (c) Blank space for MCCB 415 Volts, 40 Amp rating, 4 Pole microprocessor based (Service Breaking Capacity 18 kA 02 No (For Spare). (d) Internal wiring of panel with stranded copper cable of suitable size (e) LED phase indicating lamp(Set of three)-01 Set (f) Stenceling of pannel board including marking of distribuitions
Supply, installation, testing and commissioning of CPRI approved Factory made and tested indoor and cubical type double door Panel board suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with air insulated PVC sleeved with heat shrink of colour code on copper bus bar of rating 200 Amps for phases and 100 Amps for neutral fixed on epoxy insulators. The panel shall be weather proof, dust and vermin proof IP-54 class protection and fabricated out of 2 mm thick CRCA sheet duly powder coated after seven tank process and pedestal duly fabricated out of equal angle of size 50 x 50 x 6 mm thick MS angle iron frame work duly embedded in PCC 1:3:6 with suitable space / grooves for cable entry and exit. The panel shall be both front and rear opening centre opening doors on hinges with industrial type locking arrangments type adequate space all around acessories complete with multilayer layer chambers to accomodate each LT switchgears and measuring instruments as furnished below and including internal wiring in the panel with PVC insulated multi-stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size as per standard is practices and comprising of followings acessories.
INCOMINGS: (a) MCCB 415 Volts,100 Amp rating, 4 Pole microprocessor based (Service Breaking Capacity 18 kA Icu=100% Ics- 01 No (b) Digital volt meter 0-500 Volts-01 (c) Digital Ampere meter 0-300 Amps with and including CTs OUTGOING: (a) MCCB 415 Volts,63 Amp rating, 4 Pole Thermal magnetic relay (Service Breaking Capacity 18 kA) Icu=100 % Ics- 02 No (b) MCB SPN 230 Volts, 32 Amp rating, 2 Pole (Service Breaking Capacity 10 kA) - 06 No (d) Internal wiring of panel with stranded copper cable of suitable size. (e) LED phase indicating lamp(Set of three)-01 Set (f) Stenceling of pannel board including marking of distributions
Supply and fix MCB DB double door SPN 4 way with MCBTPN 32Amps C series 415V 1KA(for hangar door motor) complete all as specified and directed at site by Engr-In-Charge
Taking down serviceable High bay light fittings carefully without damaging the fitting or its accessories and depositing into GE(NS)Kochi for further disposal complete all as specified and directed at site by Engr-In-Charge .Note:- Cost of removal of fittings and transportation from Naval Base to GE(NS) store yard is deemed to be included in unit rate.
Supply and fix energy saving and environmental friendly long life LED street light made up of pressure die cast alluminium housing with high efficient LED as lighting source with touhened glass having IP66 protection and impact ressistance of IK07 of make Havells cat part No ENDURACITY LINEARNEOSL70W LED75PASYBOLTG HSN CODE 9405 with and including GI pipe light grade bend to shape and MS flange using 40mm x 5mm thick 0.6 m long bend to shapes in two pairs to GI bracket and GI pole together complete with and including painting with two coats of alluminium paint over a coat of anti-corrosive red oxide primer and one run of 3 core PVC insulated FR cable with multistranded copper conductor of size 1.5sqmm from Pole mounting FRP box to LED light fitting in one run of PVC non metalic rigid PVC conduit and duly supported with MS brackets bend to shape using 25mm x 3mm thick strips bend to shape (4 pairs) complete all as specified and directed at site by Engr-In-Charge
HANGER FLOOR, REPAIRS TO DISPERSAL AREA ,ROAD/ PATH & CULVERT:
Note :- Excavation under this Schedule shall be measured and paid under Sch 'A' Part -II and Cement concrete 1:4:8 type D2, Pre-cast cement concrete 1:3:6 type C1 solid block and rendering 10mm thick shall be measured and paid under Sch 'A' Part -X
Rolling and consolidating formation surfaces in cutting using power roller of capacity exceeding 8 tonne and not exceeding 12 tonne.
Material and Labour for 200mm consolidated thick (250mm spread thickness) granular sub-base grade V ( of grading V of table 400 of MORTH Specification) using kankar or laterite, spread, rolled and consolidated to required gradient and camber with 8 to 12 tonne power roller complete all as specified and as directed.
Material and Labour for 225mm thick WMM in three layers (75mm thick each layer), using graded stone aggregate, spread rolled and consolidated to required gradient and camber with 8 to 12 tonne power roller complete all as specified and as directed.
Material and Labour for 100mm consolidated thick Dry Lean Concrete (DLC) as per IRC SP 49 of strength not less than 10 Mpa at ten days with minimum cement content 180 kg/cum using 20 mm graded stone aggregate laid with paver including spread, rolled and consolidated to required gradient and camber complete all as specified and as directed.
Material and Labour for sand filling in foundations and pavements 10mm compacted thickness including watering and consolidation complete all as specified and as directed.
Supply and laying 400 micron thick HDPE black sheet in pavements all as specified
Material and Labour for 350mm thick pavement quality concrete with min flexural strength of 45 Kg/Sqcm with using minimum cement content of 400 Kg/Cum as per design mix, using non circular synthetic fibre @ 0.25% weight of cement using of mechanical paver including vacuum dewatered level with surface vibrators, screed and needle vibrators including formwork and surface finished fair and even complete all as specified and as directed Note: Non-circular Synthetic fibre and brooming shall be measured and paid separately.
Supply only non circular synthetic fibre to be mixed in PQC as per design mix.
Surface preparation by cleaning the surface and removing any dust, unsound or contaminated material, plaster, oil, grease, corrosion deposits or algae, oil and grease deposits by mechanical means [Floor to be cleaned by using mechanised equipment such as scrubbers sanders, hot blowers, vacuum cleaners and moisture test machine etc] and priming the existing concrete surfaces with epoxy primer using NITOPRIME-25 (FOSROC LTD ) OR CIPDXY-15 (CIPT LTD) OR SIKA FLOR 161 (SIKA LTD) on clean and dry surfaces, applied in a thin continuous film using roller all as per manufacturers instructions complete all as specified and as directed
Material and labour for Providing 5mm self levelling EPU system consisting of 3mm thick NITOFLOR EU5(FOSROC LTD)OR 21N PURM + 31M(SIKA LTD OR CIPOTHANES(CIPY LTD) and 2mm thick top coat any NITOFLOR EPU 2000(FOSROC LTD) OR 21N PURPM+31M(SIKA LTD) OR CIPOTHANES(CIPY LTD)using a V notch trowel and rolled by spike roller all as specified and directed
Material and Labour for forming 20 mm wide expansion joint to the full depth of PQC or Concrete slab (350 mm average thickness ) and filled with HD 100 high compressive board applying bond braker tape on top of filler board of complete width of joint, provision of closed cell , medium density, cross linked polyethylene back up rode of 20 mm dia over filler board priming top 15 mm with approved primer and sealed with polyurethane based sealant ( complying with latest IRC -57-2006) and applying masking tape on edges of joints to prevent accidental spillage of sealant complete all as per the direction of manufacturer
Material and Labour for forming contraction /dummy joints 120 mm deep and 8 mm wide using diamond cutter with initial saw cut with 3 mm blade after concrete sets, widening the first saw cut to 8 mm wide and 22 mm deep from top, filled with expanded polyethene foam (armour board, applying bond braker bond on top of armour board for complete width of joint) priming top 8 mm with approved primer, applying masking tape on edges of joint to prevent accidental spillage of sealant and seal with polythene bond sealant 13 mm deep above the back up rode (Complying with IRC-56-2006) to closed cell, medium density cross linked polyethene back up rode of 10 mm dia for complete width of joint and removing the mask tape after filling sealant complete all as specified and directed by manufacturer .
All as per item No 121 above but for construction joint 12 mm deep and 8 mm wide .
Material and Labour for preparation of new surfaces of rigid pavement over 10cm width of girth and painting lines dashes arrows, letters on roads, pavement and the similar work etc and marking with road marking paint any tint.
Preparation of existing surfaces by brushing with wire brushes for removing caked mud etc. sweeping with brooms and finally fanning the cleaned surface with air compressor to remove all loose dirt etc and applying evenly a tack coat with bituminous primer using VG -10 @ 5 kg/ 10 Sqm ( as per MORTH ) complete all as specified and directed.
Material and Labour for 150mm thick in two layers of 75mm in each layer DBM grade II having Marshal stability 900Kg using minimum 4.5% bitumen VG 30 (actual quantity of bitumen as per design mix) rolled and compacted to required gradient and camber complete all as specified and directed.
Finishing surface of concrete pavements by belting and brooming complete all as specified and directed.
Material and Labour for 150mm thick granular sub base (GSB) deposited, spread, watered and rolled by using 8 to 12 tonne power roller to form a uniform surface complete all as specified and as directed.
Material and Labour for 75mm compacted thickness WMM in runway/road, with granite coarse aggregate of approved grading, mixed with stone dust, spread, rolled and consolidated to required gradient and camber with 8 to 12 tonne power roller to form a uniform surface complete all as specified and as directed.
Preparing WMM surfaces by brushing with wire brushes for removing caked mud etc. sweeping with brooms and finally fanning the cleaned surface with air compressor to remove all loose dirt etc complete all as specified and as directed.
Preparing existing bituminous surfaces by brushing with wire brushes for removing caked mud etc. sweeping with brooms and finally fanning the cleaned surface with air compressor to remove all loose dirt etc complete all as specified and as directed.
Material and Labour for applying evenly a priming/tack coat with bituminous primer at 10 Kg/10Sqm using paving bitumen complete all as specified and as directed.
Material and Labour for applying evenly a priming/tack coat with bituminous primer at 5 Kg/10Sqm using paving bitumen complete all as specified and as directed.
Material and Labour for bituminous premix asphaltic semi dense concrete, 40mm consolidated thickness with 5.50% binder content by weight of total mix, rolled and compacted to required camber and gradient complete using paving bitumen complete all as specified and as directed.
Material and Labour for two coats of antifungal paint over a coat of exterior primer over exterior sealent base coat on newly plastered surfaces of wall including preparation of surfaces complete all as specified and as directed.
Material and Labour for Preparation of new steel surfaces and applying two coats of anti corrosive paint over appropriate primer as per manufacurers instruction complete all as specified and as directed.
SEWAGE DISPOSAL: Material and Labour for 163mm internal diameter DCWPE pipes laid in trenches and jointed complete all as specified and as directed.
ROOF TOP SPV PLANT
Designing, supply, erection, installation,commissioning and testing of Roof top solar photovoltaic power plant (ON-GRID) on roof top of proposed hanger( GI Roof) of total capacity 200 KWp (AC) fixed tilt type, and power evacuation at 415 Volt 3 phase system all as per guidelines/norms issued by MNRE & Indian Meteorological Deptt approved Solar Radiation Data viz Direct Normal Irradiance, Global Horizontal Irradiance etc complete comprising with the following:-
SOLAR PHOTO VOLTAIC PLANT:
Supply, erection, installation, commissioning and testing Solar PV Modules capable for generating 200 KWp (AC) electricity at 415 Volt 3 phase system. These Solar PV Modules shall be as per approved design parameters, with Mono Crystalline Silicon Solar cells of minimum wattage of 330/325 Wp with minimum 72 cells & efficiency not less than 18 %, conforming to IEC 61215, IEC 61730, IEC 61701, IEC-61646, IEC-62108 and must be tested and approved by one of the IEC authorised test centre. Solar PV Module and cells should be of approved Indian Brand only and Qualify under the Domestic Content requirement (DCR) norms of NVVN/SECI and testing requirement fixed by MNRE. The PV modules will be warranted for a minimum period of 25 years. Solar PV modules used in System must be warranted for their output peak watt capacity, which should not be less than 90% at the end of Ten years and 80% at the end of Twenty Five years. Each Solar PV Module must use RF identification tag. The following information must be mentioned in the RFID used in each module: - Name of manufacture of PV module Name of manufacturer of Solar cell Month & year of manufacturer (for solar cell and module) Country of origine (It is mandatory to use cells and modules manufactured in India). I-V curve of the module Wattage, L-M, V-M, & FF for the module Unique Serial No & Model No of the module Date & year of IEC PV qualification certificate Name of the test lab issued IEC certificate The PV modules used in the solar power projects must qualify to the latest edition of the following International Electrotechnical Commission (IEC) PV module qualification test or equivalent BIS Standards. The PV module must be tested and approved by one of the IEC authorized test centres. In addition, a PV module qualification test certificate as per IEC standard, issued by EDTC, Bangalore or solar energy entre will also be valid.make of SPV panel :- ADANI/TATA/WAREE
BIS standards: crystalline Silicon Solar Cell Mopdules: IEC 61215/BIS 14286 Thin Film Modules: IEC 61646 / Equivalent BIS Concentrator PV Modules : IEC 62108 / Equivalent BIS PV modules sandy environment: IEC 600068-2-68 PV modules corrosive atmosphere: IEC 61701 / BIS 61701 PV module (For construction & safety): IEC 61730 (part I & II ) / Equivalent BIS
Material and labour for Module Mounting structure (MMS) fabricted from hot dipped GI section of suitable size with specified tilt angle according to site requirement & Optimum angle to achieve Max benefit of solar energy and suitable to withstand 150 Kmph wind speed all as approved design parameters complete. Module mounting structure on GI roof sheets shall be non-penetrating type fixed to the roof sheets by using specially designed clips to mount the PV Panel on roofing system as per approved pattern of roof sheets.
Supply , laying & Testing required qty of DC cable 1x 4 sq mm multi strand tinned copper, conforming to relavant IS, weather proof UV resistant with operating temperature up to 120 degrees, minimum rated voltage 1100 volt for inter connection of SPV Modules including suitable type of cable lugs, male & female MC4 connectors & joints etc.
Supplying, erection, installation, commissioning and testing required qty of junction boxes / SMBs for 200 KWp AC output all as per approved design & layout plan for combining output of Solar PV modules DC rating of breaker of designed rating with string fuses on both positive and negative side of each string complete with SMB Voltage rating 1000 V, Copper bus bar, weather proof enclosure with NEMA rating complete.
Supply , laying & Testing required qty of DC cable 2 runs 1x 6 sq mm multi strand tinned copper conductor through PVC conduit 20 mm dia ISI marked, weather proof UV resistant with operating temperature up to 120 degrees for connection from String junction box to Inverter / PCUs including suitable type of cable lugs, male & female MC4 connectors & joints etc.
Supply, erection, installation, commissioning and testing of Grid tie Solar Power conditioning unit / inverter of total capacity 200 KWp (DC to AC 415 V in Three phase system) all as per approved design parameters & capable of generating output voltage 415 V AC at rated load condition with efficiency not less than 98 %, conforming to IEC 600682-2 /VDE standards with power reduction, LVRT with protections for anti-islanding, Ground fault monitoring, Grid Monitoring, AC & DC Over voltage and under voltage protection, AC & DC short/over current protection, and DC reverse polarity protection, graphic display etc. all as specified and as directed. Nominal Voltage: 415V ± 10%, 3 Phase, 50 Hz. Control: Microprocessor / DSP Switching device: IGBT / MOSFET Grid Freq Synchronization: ± 3 Hz or more Ambient Temperature: -20˚C to 50˚C Humidity: 95 % non-condensing Protection of enclosure: IP 20 ( Indoor) / IP 65 ( outdoor) No Load Losses: < 1% of rated power Inverter Efficiency: >97% ( without inbuilt galvanic isolation) >93% ( with inbuilt galvanic isolation) PF: >0.>0.9 THD: <3% The Inverter should have internal protection arrangement against any sustainable fault in feeder line and against the lighting on feeder Should have isolation transformer. The inverter generated harmonics, flicker, DC injection limits, Volt range, frequency range and anti-islanding measures should follow the latest guidelines / IEC 62116/ BIS Code. AC, 415V copper cables or required size from individual inverter to invertor panels and invertor panel for evacuating 200 KW AC supply are deemed to be included in the rate againt SPV Plant and nothing extra shall be payable on this acount Copper cables .Make of Inventor: DELTA/KIRLOSKAR/ABB
Technical requirement of BoS items of SPV plants: Technical specifications of power conditioners including MMPT & Protection for use in grid solar power plants are as under: - Environmental Testing:IEC 60068-2/ Eq IS Efficiency Measurement:IEC 616833 / IS 61683 Product safety: IEC 62109- 1 & 2 Grid connectivity Interface: IEC 61727:2004 Interconnection PV invertors: IEC 62116 Electromagnetic interface: IEC610002,3,6 Ingress protection: IP 54 & IP 21 Batteries: AS PER relevant BIS Std Cables: IEC 60227/IS 3043:1986 Earthing / Lightening: IEC 62561/IS 3043 :1986 Surge arrestors: IEC 60634-5-53/Relevant IS Code Circuit Breakers: IEC 60947 1, 11,III 60947 EN 50521 Junction Boxes & Enclosures: IP 65 / IP 21 Meters: AS Per DISCOM Guidelines / IS 16444 Grid connectivity: As prevalent in the state/as per CEA Warranty : The mechanical structures, electrical works, and SPV power system must be warranted for a minimum of 5 Years
Supply,installation,commissioning and testing of LT 415 Volt GRID panels outdoor type for Power evacuation and Grid interconnection systems with the existing LT Panel at loaction marked in the Drg / directed by Engr-in-charge at site with rated capacity of Circuit Breakers at both side, bus bar, CTs, digital Metering , relays,Gross-metering, etc all as per approved design parameters with totally enclosed, fully interlocked, metal clad power coated enclosure including PCC foundation complete. Note: Earth work & LT cable of sizes required for connection from Inverter panel to Grid panel shall be measured and paid separately.
Modification of existing LT panel / Feeder pillar box by exentesion of busbar for inter connection with and including MCCBs of rated capacity, sheet metal enclosure complete & connecting.
Material and labour for required qty of Lightning protection for SPV modules etc as per IE rule, MNRE guide line & BIS all as per approved plan complete with galvanised earth plate electrode 600x600x6 mm thick buried directly in ground vertically (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to and including GI strip 32x6mm size protected with G I medium grade pipe 40mm dia for earth electrode up to test point by means of GI nuts, bolts, check nuts and washers including earth work, excavation, PCC pit and RCC cover ( 1:2:4 type B1) and funnel, with necessary charcoal, salt etc;complete all as per electrical plate No.3 of SSR Part - I.
Material and labour for aluminium strip of size 25 x 3mm thick for roof / down conductor fixed on insulators/ saddles of suitable size for SPV modules lightning protection.
Material and labour for artistic painting in black letters with yellow background for Solar array structures, junction box , Earth chambers, PCU's, DB's etc.. all as specified and as directed.
Material and labour for earthing for Lightning protection of Panels, Inverter etc as per IE rule, MNRE guide line & BIS all as per approved plan complete with galvanised earth plate electrode 600x600x6 mm thick buried directly in ground vertically (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to and including GI strip 32x6mm size protected with G I medium grade pipe 40mm dia for earth electrode up to test point by means of GI nuts, bolts, check nuts and washers including earth work, excavation, PCC pit and RCC cover ( 1:2:4 type B1) and funnel, with necessary charcoal, salt etc;complete all as per electrical plate No.3 of SSR Part - I.
Supply & lay synthetic rubber mat of size 2m x 1m x 10mm - 01 No each per panel (a) Weather monitoring station(WMS)consisting of IR sensor, ambient temperature sensor and module Temp sensor to be provived.(b)Remote plant monitoring system with PC/laptop, UPS and software as per OEM recommendation shall be provided(c)Module cleaning system with network of PVC/HDPE pipes, covering entire panels shall be provided. Water points shall be taken from 2 locations at either side of hangar at ground floor. Cost towards necessary pipes from source storage tank, staging and connected works shall be deemed to be included in the price quoted against SPV plant.
Note (i) Before commencement of work, contractor shall submit working drawings & lay out plan with scale including qty required duly vetted by IIT/NIT to Accepting Officer for approval. The working drawing must includes the following. (a)Single line/Schematic diagram of Solar PV power plant (b) Designing of Solar PV strings layout, SMBs / junction boxes , Cable route etc (c) Details of Mounting Structure,roof clips, tilting angle, size of sections, junction box,position, LT Cable Network (DC & AC) layout, Lightening Protection System, Earthing System Invertor type & make etc. (d) Any other details required for successful installation commissioning, testing and smooth and stable operation of Solar PV plant.
Note (ii) (a) The mechanical structures, electrical works and overall workmanship of the Grid solar power plant must be warrented for a minimum of 5 years. (b) All Mechanical, Electrical works shall be carried out as per relevant BIS/IS/equivalent standard norms only and also in accordance with the latest edition of the Indian Electricity Act / rules formed thereunder and as amended from time to time. (c) Any other works (mechanical & electrical) connected to installation, testing & functional requirement of solar photovoltaic power plant of capacity 200 KW (AC) all as mentioned above and which is not mentioned or included in this Schedule A , but necessary shall be carried out by the contractor. (d) Contractor shall provide adequate Spares required minimum for 1 year maintenace including DC & AC items under scope of work
Note (iii) (a) Entire plant shall be tested after successful commissioning by Senior Electrical Inspector. (b) Contractor shall organize presence of an electrical consultant at site at the time of commissioning with no additional charges to MES. The consultant / site engineer shall have adequate expertise in the form of knowledge/ experience in this field. He shall be able to guide the site team on the steps/ procedure/ precautions to be adopted during commissioning. Also, he shall be cable of extempore trouble-shooting in case of any technical problems encountered on SPV portions up to connection to existing LT distribution system. Contractor will submit credentials of the proposed consultant for MES approval prior to awarding of work/ availing their service.
Supply and fixing, testing comissioning XLPE insulated screened PVC bedded galvanised steel strip or wire armoured power cable (Heavy duty) 1100 V grade with stranded aluminium conductor of size 3.5 core 400 Sqmm on poles /walls as cable for aviation obstruction light all as specified and directed.
Material and labour for cable route indicator 15cm dia made out of cast aluminium duly marked with size and type of cable fixed on ISA 40x40x6mm angle iron support embedded including in PCC 1:2:4 type B1 (300x300x400mm) and steel surface painted with two coats of anti corrosive paint over a coat of red oxide primer including necessary earth work all as specified and directed.
Supply & Fix indoor LT panel made out of CRCA sheet 2mm thick powder coated welded on suitable C channel base frame duly fixed in floor with following accessories suitable for incoming/ outgoing arrangements:- (a) ACB 1600 AMP 50KA 4 pole MDO type (Microprocessor based release) - 01 No (Incoming) (b) ACB 1000 AMP 50KA 4 pole MDO type (Microprocessor based release) - 03 Nos (c) MCCB 630 AMP 36KA 4 pole (Adj thermal& adj magnetic) - 02 Nos (d) MCCB 630 AMP 36KA 4 pole (Adj thermal& adj magnetic) - 01 Nos (e) Aluminium bus bar 2400 Amp TPN - 01 Set (f) LCD multi function meter - 01 No (g) Modular indicator 3 phase -01 Set of three (h) CT of suitable ratio 1500/5 A - Set of 3 Nos
JAIN BUILDER
A2Z ENGINEERS AND PILE FOUNDATIONS
Mecone Construction Contractors
AKM CONSTRUCTION AND ENGINEERING LLP
Rabina Enterprises Pvt Ltd
RDS PROJECT LTD
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid