Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹1.5 L
Closing Date
26 Oct 2026, 3:00 pm
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Works)
Pratapnagar: Electrical works in connection with up-gradation of Admin block and locker facility in Workshop and repair works of existing NG Diesel Shed and office building.
BRC-EL-P-25-2601-04-26-27~WR
BRC-EL-P-25-2601-04-26-27
Open
Works - General
6 Months
Vadodara, Gujarat
₹0
₹1.5 L
28 Sept 2026
28 Sept 2026
12 Oct 2026
95 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 63,55,047 | ||
| — | 225.00 | — | — | ||
| Wiring of light/fan/exhaust fan point in PVC casing-capping/conduit - The price shall cover for wiring of light/fan/exhaust fan point with 1.5 sq. mm, multi-stranded, PVC insulated, unsheathed FRLS copper conductor of 1100 Volt grade, ISI marked, conforming to relevant and latest IS and 1.0 sq. mm, single-core, multi-stranded, PVC insulated, unsheathed FRLS copper conductor of 1100 Volt grade, ISI marked, conforming to relevant and latest IS in medium grade PVC casing-capping double lock type, ISI marked or medium grade PVC conduit of not less than 19 mm diameter, ISI marked as per site conditions with surface mounted molded polypropylene switch board with modular cover plate of suitable size including switches/angular holders/ceiling rose. Space shall be kept on board to accommodate modular electronic fan regulator. Molded polypropylene switch board shall be as per IS: 14772. | — | — | — | 75,150 | |
| — | 40.00 | — | — | ||
| Providing plug point, 6 Amp in existing board - The price shall cover for providing plug point with modular type universal socket and switch, 6 Amp, 230 Volt, AC on existing board. The accessories shall be of modular type. | — | — | — | 4,200 | |
| — | 30.00 | — | — | ||
| Providing board with two switches and two sockets, 6 Amp - The price shall cover for wiring of multi-plug point (switch, 6 Amp, 230 Volt AC, 50 Hz - 2 Nos and socket, 6 Amp, 6 Amp, 230 Volt AC, 50 Hz - 2 Nos) on separate surface mounted polypropylene switch board with modular cover plate of suitable module with 1.5 sq. mm multi-stranded, PVC insulated, unsheathed FRLS copper conductor and 1.0 sq. mm multi-stranded, PVC insulated, unsheathed FRLS copper conductor in green colour as earthing wire of 1100 Volt grade, ISI marked, conforming to relevant and latest IS in medium grade PVC casing capping double lock type, ISI marked or medium grade PVC conduit of not less than 19 mm diameter, ISI marked as per site conditions at an approximate distance up to 3.0 meter or as per site requirement. The accessories shall be of modular type. Molded polypropylene switch board shall be as per IS: 14772. | — | — | — | 6,420 | |
| — | 10.00 | — | — | ||
| Providing board with four switches and four sockets, 6 Amp - The price shall cover for wiring of multi-plug point (switch, 6 Amp, 230 Volt AC, 50 Hz - 4 Nos and socket, 6 Amp, 6 Amp, 230 Volt AC, 50 Hz - 4 Nos) on separate surface mounted polypropylene switch board with modular cover plate of suitable module with 1.5 sq. mm multi-stranded, PVC insulated, unsheathed FRLS copper conductor and 1.0 sq. mm multi-stranded, PVC insulated, unsheathed FRLS copper conductor in green colour as earthing wire of 1100 Volt grade, ISI marked, conforming to relevant and latest IS in medium grade PVC casing capping double lock type, ISI marked or medium grade PVC conduit of not less than 19 mm diameter, ISI marked as per site conditions at an approximate distance up to 3.0 meter or as per site requirement. Molded polypropylene switch board shall be as per IS: 14772. | — | — | — | 4,940 | |
| — | 20.00 | — | — | ||
| Providing plug point, 15/16 Amp on separate board - The price shall cover for providing modular power plug point with flush type universal 5 pin socket and switch 15/16 Amp, 230 Volt AC, 50 Hz on separate surface mounted molded polypropylene switch board with modular cover plate of suitable module with 2.5 sq. mm multi-stranded, PVC insulated, unsheathed FRLS copper conductor and 1.5 sq. mm multi-stranded, PVC insulated, unsheathed FRLS copper conductor in green colour as earthing wire of 1100 Volt grade, ISI marked, conforming to relevant and latest IS in medium grade PVC casing capping double lock type, ISI marked or medium grade PVC conduit of not less than 19 mm diameter, ISI marked as per site conditions at an approximate distance up to 3.0 meter or as per site requirement. Molded polypropylene switch board shall be as per IS: 14772. | — | — | — | 8,840 | |
| — | 70.00 | — | — | ||
| Providing Electronic fan regulator, modular type - The price shall cover for supply, fixing, testing and commissioning of hum-free modular type electronic fan regulator suitable for 80/100-Watt ceiling fan of step type with 'OFF' position, surface/flush type on existing board and its connection from existing supply. The colour of regulator should be in sync with the switch board. Miniature switch type regulators shall not be accepted. The regulator shall be got approved from site engineer before supply and installation. | — | — | — | 17,920 | |
| — | 750.00 | — | — | ||
| Wiring of sub-main with copper wire, single-core, 2.5 sq. mm in casing-capping/conduit - The price shall cover for wiring of two wire sub- main with 2.5 sq. mm PVC insulated, unsheathed, multi-stranded, FRLS copper conductor of 1100 Volt grade, ISI marked, conforming to IS: 694/1990 with one wire of 1.5 sq. mm PVC insulated, unsheathed, multi-stranded, FRLS copper conductor of 1100 Volt grade, ISI marked, conforming to IS: 694/1990 in medium grade PVC casing capping of not less than 25 mm size, double lock type, ISI marked or medium grade PVC conduit of not less than 19 mm diameter, ISI marked as per site conditions. | — | — | — | 76,500 | |
| — | 12.00 | — | — | ||
| Providing Air circulator fan, 750 mm sweep, heavy-duty industrial type complete with all accessories - The price shall cover for supply of heavy duty, wall mounted, Air Circulator fan, 750 mm sweep (approximately) having aluminium alloy one piece blade, double ball bearing, 90° oscillation, sturdy, closed mesh guard, single phase motor, to work on 230 Volt, 50 Hz single phase AC supply. The air circulator fan shall be got approved from site engineer before supply. The Air Circulator fan shall be provided with three core FRPVC copper flexible cord 48/0.20 mm size of suitable length. The Air Circulator shall be fitted on the structure/wall/pillar by providing M.S. clamp of 50 x 5 mm made from M. S. flat duly painted with two coats of anti- corrosive red oxide and two coats of silver enamel paint by providing proper rake bolts. The circulator shall be connected with existing supply point as per site conditions. | — | — | — | 1,16,652 | |
| — | 400.00 | — | — | ||
| Providing four-core, multi-stranded, flexible copper cable, 2.5 sq. mm from indoor to outdoor unit of Split Air Conditioner - The price shall cover for supply, fixing, testing and commissioning of PVC insulated, multi-stranded, four-core, copper conductor cable, 2.5 sq. mm, 1100 Volt grade, ISI marked, conforming to IS: 694 or latest. The cable shall be connected from the indoor and outdoor units of split A.C. along with 8 SWG earth wire in PVC sleeve of good quality for earthing the equipment from existing nearby earth point/electrode. The copper wire and earth wire shall be laid in PVC conduit of suitable size and properly fixed. | — | — | — | 62,800 | |
| — | 984.00 | — | — | ||
| Providing copper piping for suction and discharge lines of Air Conditioner unit - The price shall cover for supply, fixing, testing and commissioning of refrigerant copper piping suitable for R-22, R-134 A, R-407 refrigerant and conforming to IS: 10773/2006 (latest) from indoor unit to outdoor unit. The copper piping shall be insulated with polyurethane foam tubing duly covered with weather protection. The copper refrigerant pipe shall be suitable for bearing 350 PSI pressure and the thickness should be 19 SWG and diameter should be suitable for handling of refrigerant for capacity 3.5 TR of refrigerant quantity without creating any extra pressure due to quantity of refrigerant and as per manufacturer's recommendations. The exposed copper piping shall be suitably concealed as per site requirement. | — | — | — | 3,03,072 | |
| — | 984.00 | — | — | ||
| Providing rigid PVC drain piping - The price shall cover for supply and fixing of rigid uPVC pipe medium grade of required diameter from indoor unit to main drain hole for draining of condensed water from cooling coil (Indoor unit) to main drain discharge point. | — | — | — | 39,360 | |
| — | 30.00 | — | — | ||
| Supply and fixing of MS stand for outdoor unit of Split Air Conditioner - The price shall cover for supply, fixing and commissioning of MS angle frame/stand made from MS angle for outdoor unit of split AC. The stand shall be of universal design suitable for mounting of outdoor units of capacity 1.0 TR to 2.0 TR Split Air Conditioners. The stand shall be made with thick CRC Steel with additional hemming bend for added strength. The thick steel shall be finished with weather proof, seven tank powder coating of shade as advised by site engineer. The stand shall be tested for 160 kg load. The stand shall be fixed at site with anchor bolts. Necessary civil works involved are included in the scope of work. | — | — | — | 12,870 | |
| — | 30.00 | — | — | ||
| Installation, testing and commissioning of Split Air Conditioner - The price shall cover for installation, fixing, testing and commissioning of the split AC as per the site-engineer's instructions/ requirements with all associated wiring, copper piping, existing drain piping, existing MS outdoor stand. This shall also cover for making a hole of suitable diameter in the existing brick masonry/RCC wall for laying of cables, pipes etc. from indoor to outdoor unit in a neat and aesthetic manner. The hole shall be sealed with plaster of Paris to prevent entry of insects, rain water, lizards etc. Manufacturer's recommendations/ instructions shall be strictly followed. Split AC shall be supplied by railways from the site engineer's office/ stores. | — | — | — | 43,350 | |
| — | 4.00 | — | — | ||
| Providing lighting control board with MCB DP, 32 Amp - 1 No, Time Switch, 16 Amp - 1 No and Single-Phase Contactor, 32 Amp - 1 No - The price shall cover for supply, fixing, testing and commissioning of lighting control board fabricated from CRCA sheet steel, powder coated with grey finish, dust and vermin proof, water resistant with metallic door complete with MCBs of 10 KA breaking capacity. The board shall be equipped with MCB DP, 10 KA breaking capacity, 32 Amp rating - 1 No, Time switch, 16 Amp - 1 No and Single-phase contactor of rating 32 Amp - 1 No. The board shall be completely wired with multi-stranded copper wire of suitable capacity and shall be provided with heavy duty connectors of suitable capacity for termination of incoming and outgoing wires and shall be provided with two nos of earthing terminals on each side of the board and riveted metallic caution board in three languages. | — | — | — | 17,280 | |
| — | 20.00 | — | — | ||
| Providing lighting control board with incomer MCB TPN, 32 Amp - 1 No and outgoing MCB DP, 16 to 32 Amp - 4 Nos with time switch, 16 Amp - 3 Nos and single phase contactor, 32 Amp - 3 Nos - The price shall cover for supply, fixing, testing and commissioning of lighting control board fabricated from CRCA sheet steel, powder coated with grey finish, dust and vermin proof, water resistant with metallic door complete with MCBs of 10 KA breaking capacity. The board shall be equipped with incomer MCB TPN, 10 KA breaking capacity, 32 Amp rating - 1 No, outgoing MCB DP, 10 KA breaking capacity, 16 to 32 Amp - 4 Nos, Time switch, 16 Amp - 3 Nos and Single-phase contactor of rating 32 Amp - 3 Nos. The board shall be completely wired with multi-stranded copper wire of suitable capacity and shall be provided with heavy duty connectors of suitable capacity for termination of incoming and outgoing wires and shall be provided with two nos of earthing terminals on each side of the board and riveted metallic caution board in three languages. | — | — | — | 1,13,620 | |
| — | 8.00 | — | — | ||
| Providing Distribution Board, double-door, with incomer MCB TPN, 63 Amp - 1 No, RCBO four-pole, 63 Amp - 1 No and outgoing MCB DP, 16/20/32 Amp - 10 Nos - The price shall cover for supply, fixing, testing and commissioning of pre-fabricated, double door, MCB distribution board fabricated from CRCA sheet steel, powder coated with grey finish, dust and vermin proof, water resistant with metallic door complete with MCBs of 10 KA breaking capacity. The DB shall be equipped with incomer MCB TPN, 63 Amp - 1 No, RCBO four-pole, 30 mA sensitivity, 63 Amp - 1 No and outgoing MCB DP, 10/16/20 Amp - 10 Nos. The board shall be completely wired with multi-stranded copper wire of suitable capacity and shall be provided with heavy duty connectors of suitable capacity for termination of incoming and outgoing wires and shall be provided with two nos of earthing terminals on each side of the board and riveted metallic caution board in three languages. The Distribution Board shall be suitable for surface/ recessed installation. | — | — | — | 1,32,824 | |
| — | 10.00 | — | — | ||
| Providing Distribution Board, outdoor type, double-door, wall/floor mounted with incomer MCCB, four-pole, 125 Amp - 1 No, outgoing MCB TPN, 63 Amp - 2 Nos and MCB DP, 20/25 Amp - 4 Nos with power plug socket, three-phase, 63 Amp - 2 Nos and power plug socket, single-phase, 20 Amp - 1 No with indication lamps, earthing terminals and all accessories - The price shall cover for design, supply, installation, testing and commissioning L.T. Distribution Panel fabricated from 2.0 mm thick M.S. sheet, standard angles, channels etc. as required in design.The LT panel shall be indoor/outdoor type, double-door, rectangular cubicle type, dust and vermin proof suitable for floor mounting for three-phase, four-wire, 415 Volt, 50 Hz AC supply system. Detailed specifications are given in Annexure-XXI of tender document. | — | — | — | 5,17,390 | |
| — | 2.00 | — | — | ||
| Providing Distribution Board, outdoor type, double-door, wall/floor mounted with incomer MCCB, four-pole, 250 Amp - 1 No and outgoing MCCB, four-pole, 100 Amp - 2 Nos and MCCB, four-pole, 63 Amp - 4 Nos with indication lamps, earthing terminals and all accessories - The price shall cover for design, supply, installation, testing and commissioning L.T. Distribution Panel fabricated from 2.0 mm thick M.S. sheet, standard angles, channels etc. as required in design.The LT panel shall be indoor/outdoor type, double-door, rectangular cubicle type, dust and vermin proof suitable for floor mounting for three-phase, four-wire, 415 Volt, 50 Hz AC supply system. Detailed specifications are given in Annexure-XXI of tender document. | — | — | — | 2,61,118 | |
| — | 1.00 | — | — | ||
| Providing Distribution Board, outdoor type, double-door, wall/floor mounted with incomer MCCB, four-pole, 200 Amp - 1 No and outgoing MCCB, four-pole, 63 Amp - 6 Nos with multifunction energy meter, indication lamp and all accessories - The price shall cover for design, supply, installation, testing and commissioning L.T. Distribution Panel fabricated from 2.0 mm thick M.S. sheet, standard angles, channels etc. as required in design.The LT panel shall be indoor/outdoor type, double-door, rectangular cubicle type, dust and vermin proof suitable for floor mounting for three- phase, four-wire, 415 Volt, 50 Hz AC supply system. Detailed specifications are given in Annexure-XXI of tender document. | — | — | — | 1,37,396 | |
| — | 2.00 | — | — | ||
| Providing Distribution Board, outdoor type, double-door, wall/floor mounted with incomer MCCB, four-pole, 400 Amp - 1 No and outgoing MCCB, four-pole, 250 Amp - 2 Nos and MCCB, four-pole, 125 Amp - 6 Nos with indication lamps, earthing terminals and all accessories - The price shall cover for design, supply, installation, testing and commissioning L.T. Distribution Panel fabricated from 2.0 mm thick M.S. sheet, standard angles, channels etc. as required in design.The LT panel shall be indoor/outdoor type, double-door, rectangular cubicle type, dust and vermin proof suitable for floor mounting for three-phase, four-wire, 415 Volt, 50 Hz AC supply system. Detailed specifications are given in Annexure-XXI of tender document. | — | — | — | 3,34,502 | |
| — | 1.00 | — | — | ||
| Providing Distribution Board, outdoor type, double-door, wall/floor mounted with incomer MCCB, four-pole, 250 Amp - 2 Nos and outgoing MCCB, four-pole, 200 Amp - 3 Nos, MCCB, four-pole, 100 Amp - 6 Nos and MCCB, four-pole, 63 Amp - 6 Nos with multifunctional energy meter, indication lamps, earthing terminals and all accessories - The price shall cover for design, supply, installation, testing and commissioning L.T. Distribution Panel fabricated from 2.0 mm thick M.S. sheet, standard angles, channels etc. as required in design.The LT panel shall be indoor/outdoor type, double-door, rectangular cubicle type, dust and vermin proof suitable for floor mounting for three-phase, four-wire, 415 Volt, 50 Hz AC supply system. Detailed specifications are given in Annexure-XXI of tender document. | — | — | — | 1,89,288 | |
| — | 1.00 | — | — | ||
| Providing Distribution Board, outdoor type, double-door, wall/floor mounted with incomer MCCB, four-pole, 400 Amp - 2 Nos and outgoing MCCB, four-pole, 200 Amp - 3 Nos, MCCB, four-pole, 100 Amp - 3 Nos, MCCB, four-pole, 63 Amp - 4 Nos and MCB TPN, 25/32 Amp - 6 Nos with multifunctional energy meter, indication lamps, earthing terminals and all accessories - The price shall cover for design, supply, installation, testing and commissioning L.T. Distribution Panel fabricated from 2.0 mm thick M.S. sheet, standard angles, channels etc. as required in design.The LT panel shall be indoor/outdoor type, double-door, rectangular cubicle type, dust and vermin proof suitable for floor mounting for three-phase, four-wire, 415 Volt, 50 Hz AC supply system. Detailed specifications are given in Annexure-XXI of tender document. | — | — | — | 2,03,582 | |
| — | 1.00 | — | — | ||
| Providing Distribution Board, indoor/outdoor type, double-door, floor mounted with incomer MCCB, four-pole, 400 Amp - 1 No and outgoing MCCB, four-pole, 250 Amp - 4 Nos and MCCB, four-pole, 125 Amp - 6 Nos with multifunction energy meter, indication lamp and all accessories - The price shall cover for design, supply, installation, testing and commissioning L.T. Distribution Panel fabricated from 2.0 mm thick M.S. sheet, standard angles, channels etc. as required in design.The LT panel shall be indoor/outdoor type, double-door, rectangular cubicle type, dust and vermin proof suitable for floor mounting for three-phase, four-wire, 415 Volt, 50 Hz AC supply system. Detailed specifications are given in Annexure-XXI of tender document. | — | — | — | 2,44,883 | |
| — | 4.00 | — | — | ||
| Providing Distribution Panel, indoor/outdoor type, double-door, floor mounted with incomer MCCB, four-pole, 630 Amp - 1 No and outgoing MCCB, four-pole, 400 Amp - 2 Nos, MCCB, four-pole, 250 Amp - 2 Nos and MCCB, four-pole, 125 Amp - 6 Nos with multifunctional energy meter, indication lamp, earthing terminals and all accessories - The price shall cover for design, supply, installation, testing and commissioning L.T. Distribution Panel fabricated from 2.0 mm thick M.S. sheet, standard angles, channels etc. as required in design.The LT panel shall be indoor/outdoor type, double-door, rectangular cubicle type, dust and vermin proof suitable for floor mounting for three-phase, four-wire, 415 Volt, 50 Hz AC supply system. Detailed specifications are given in Annexure-XXI of tender document. | — | — | — | 15,88,736 | |
| — | 100.00 | — | — | ||
| Supply and laying of flexible copper cable, four-core 4.0 sq mm - The price shall cover for supply of XLPE sheathed and insulated, LTUG cable, four-core, 4.0 sq. mm, stranded Copper conductor, 1100 Volt grade conforming to IS: 7098 Part I (latest), ISI marked. A copy of test certificate shall be submitted along with the cable. The cable shall be laid as per the instructions of site engineer. Suitable cable terminations are included in the scope of work. | — | — | — | 30,400 | |
| — | 80.00 | — | — | ||
| Supply and laying of flexible copper cable, four-core 6.0 sq mm - The price shall cover for supply of XLPE sheathed and insulated, LTUG cable, four-core, 6.0 sq. mm, stranded Copper conductor, 1100 Volt grade conforming to IS: 7098 Part I (latest), ISI marked. A copy of test certificate shall be submitted along with the cable. The cable shall be laid as per the instructions of site engineer. Suitable cable terminations are included in the scope of work. | — | — | — | 35,600 | |
| — | 10.00 | — | — | ||
| Supply and providing rubber mat of size 2.0 x 1.0 meter and 2.5/3.0 mm thick - The price shall cover for supply and provision of ISI marked, rubber mat of size 2.0 x 1.0 meter and 2.5/3.0 mm thick Made of Dielectric "Elastomer" rubber and Synthetic Polymer as per IS: 15652-2006 (latest) of size 2.0 x 1.0 meter and 2.5/3.0 mm thick in HT/LT panel room for electrical insulation above the ground. The rubber mat shall be got approved by site engineer before supply. | — | — | — | 10,630 | |
| — | 100.00 | — | — | ||
| Supply, fixing and commissioning of FRP cable tray of size 300 x 100 x 100 mm and 4.0 mm thick - The price shall cover for supply, fixing and commissioning of FRP cable tray of size 300 x 100 x 100 mm and 4.0 mm thick. The scope of work is as under - 1. Supply and fixing GRP/FRP tray made of composite material of size 300 mm (W) x 100 mm (D) x 4 mm (Thick) complete with all accessories, support arrangements, hardware, fittings etc as per site requirement. This item shall be utilized for housing of bus duct trunking system. 2. GRP/FRP material shall have minimum 60% glass content, with properties of anti-corrosiveness, dust-proof, rust-proof, shock-proof, high-strength, weather proof, fire retardant, non- conductive, non-magnetic and maintenance free. 3. The trays should be single section pultruded, (assembled trays will not be accepted). 4. Trays shall be complete with all fixing accessories, suitable to accommodate the bus duct system. Complete design, items, accessories etc shall be as per site conditions requirement duly certified by the site-engineer. 5. Trays shall be channel/trough type and furnished as a system including all necessary fasteners, hold-down clips, support systems, covers, hinged horizontal and vertical splice plates, elbows, reducers, bends, tees, crosses etc and all necessary hardware etc. 6. Trays shall be erected in perfect level and plumb. 7. Trays shall not have sharp edges, burrs or projections injurious to the system. 8. Trays shall include fittings such as inward/outward bends, inward/outward risers, tees, reducers/expanders, crosses, Pultruded coupler plates with SS: 304 or SS: 316 hardware, horizontal and vertical moulded hinges for flexible angle bend etc. for changes in direction and elevation. 9. Trays shall have support span of 1.5 to 2.0 meter supported adequately at a minimum distance of 1.0 meter from the building structure by means of painted/ galvanized MS structural members secured to the structure by dash fasteners or by grouting. 10. The entire tray system shall be rigid. 11. Bus duct should be suitably supported/fixed with galvanized clamps / nut bolts etc. 12. The contractor shall submit delivery challan/copy of original voucher of OEM/authorized dealer to ascertain originality of the items. | — | — | — | 63,700 | |
| — | 600.00 | — | — | ||
| Providing M.S. supports fabricated from 100 mm x 50 mm size C type MS channel and 50 x 50 x 5 mm size M.S. angle for supporting FRP cable tray - The price shall cover for providing M.S. supports fabricated from 100 mm x 50 mm size C type MS channel and 50 x 50 x 5 mm size M.S. angle for supporting FRP ladder type cable tray. The M.S. Channel shall be welded to the shed pillars and cross supports of M.S. angles shall be provided for laying of FRP cable tray. The cable tray shall be fixed by means of GI nuts, bolts and washers in a safe and secure manner. Provision of suitable size of holes shall be made in channels/angles for supporting the cable tray. The M.S. channels and angles shall be painted with two coats of red oxide primer and finished with two coats of enamel paint of shade as decided by site engineer. | — | — | — | 60,000 | |
| — | 216.00 | — | — | ||
| Digging of cable trench 450/600 mm wide and 900 mm deep in all types of soil including hard, rocky etc. - The price shall cover for digging of 450/600 mm wide and 900 mm deep trench in all types of soil including soft, rocky as per cable route plan and filling back the trench after laying of cables. This also includes clearing of roots of trees and bushes and other temporary obstructions on the selected route. | — | — | — | 26,784 | |
| — | 200.00 | — | — | ||
| Digging of cable trench 200 mm wide and 200 mm deep in concrete/tar road/platform and refilling to its original position after laying of cable in HDPE pipe, 110 mm diameter - The price shall cover for digging of cable trench of size 200 x 200 mm deep in concrete/tar road/platform surface and its refilling/ plastering after laying of cable in 110 mm diameter HDPE pipe in existing trench. Supply and laying of HDPE pipe, 50 mm diameter is included in the scope of work. | — | — | — | 1,26,800 | |
| — | 35.00 | — | — | ||
| Providing PVC maxi trunking of size 100 x 50 mm - The price shall cover for supply, fixing, testing and commissioning of ISI marked PVC Maxi Trunking of size 100 x 50 mm with all accessories. The PVC Maxi trunking shall be fixed at site by fabricated clamp of 18 SWG GI sheet at a distance not more than 1.5 meters by machine screw/GI nut bolts, washers etc. The existing power cables shall be laid in the PVC Maxi trunking properly dressed and secured by means of suitable clamps/fasteners etc. | — | — | — | 16,100 | |
| — | 1000.00 | — | — | ||
| Supply and laying of RCC half round pipe, 150 mm diameter - The price shall cover for supply of half round RCC pipes of 150 mm inner diameter and 1.0 meter in length as per given description in Annexure-XXI of tender document. The internal surface shall have a smooth finish without any bulge or projections to avoid damage to the cable. The price shall also cover for laying of half round RCC pipes above the cables for mechanical protection on laid cables in the existing trench. After laying of RCC half round pipe, the trench shall be filled up with soil available thereby. | — | — | — | 76,000 | |
| — | 1000.00 | — | — | ||
| Supply and laying of DWC pipe, 63 mm diameter in trench - The price shall cover for supply of Double Wall Corrugated (DWC) HDPE pipe of 63 mm diameter. DWC HDPE pipe shall have corrugation on outer wall but inner wall shall be plain conforming to IS: 14930 Part I and II amended from time to time. The pipes shall be "ISI" marked. Accessories like HDPE snap fit coupler with neoprene 'O' ring shall be part of supply to make the joints water/damp proof. The strength and stiffness class of the pipe shall be SN4 and SN8 respectively.The price shall also cover for laying the DWC pipes in the ground below the tracks/road by push through method at a depth below the formation level as indicated in the drawing supplied by railway. The term "formation" level means the earth surface just below the bedding of the ballast. In case of any hard/stony soil, contractor should adopt new technology method in push through method. Each length of the pipes shall be joined together properly using proper size of socket and aligned in a straight line, keeping an inclination to facilitate the draining of water. | — | — | — | 76,000 | |
| — | 900.00 | — | — | ||
| Supply and laying of DWC pipe, 120 mm diameter in trench - The price shall cover for supply of Double Wall Corrugated (DWC) HDPE pipe of 120 mm diameter. DWC HDPE pipe shall have corrugation on outer wall but inner wall shall be plain conforming to IS: 14930 Part I and II amended from time to time. The pipes shall be "ISI" marked. Accessories like HDPE snap fit coupler with neoprene 'O' ring shall be part of supply to make the joints water/damp proof. The strength and stiffness class of the pipe shall be SN4 and SN8 respectively.The price shall also cover for laying the DWC pipes in the ground below the tracks/road by push through method at a depth below the formation level as indicated in the drawing supplied by railway. The term "formation" level means the earth surface just below the bedding of the ballast. In case of any hard/stony soil, contractor should adopt new technology method in push through method. Each length of the pipes shall be joined together properly using proper size of socket and aligned in a straight line, keeping an inclination to facilitate the draining of water. | — | — | — | 1,43,100 | |
| — | 300.00 | — | — | ||
| Supply and laying of HDPE pipe, 110 mm diameter by pushing method under track/road - The price shall cover for supply of HDPE (High Density Polyethylene) pipe of 110 mm nominal diameter as per IS 4984-1995 with all accessories required for laying such as coupler, bend etc. as per given description in Annexure-XXI of tender document. The price shall also cover for laying the HDPE pipes in the ground below the tracks/road by push through method at a depth below the formation level as indicated in the drawing supplied by railway. The term "formation" level means the earth surface just below the bedding of the ballast. In case of any hard/stony soil, contractor should adopt new technology method in push through method. Each length of the pipes shall be joined together properly using proper size of socket and aligned in a straight line, keeping an inclination to facilitate the draining of water. | — | — | — | 3,86,400 | |
| — | 1800.00 | — | — | ||
| Laying of cable in trench - The price shall cover for laying, testing and commissioning of LTUG armoured cable in existing trench/pipe and its connection at both ends. The cable shall be tested with 500 Volt Megger earth tester before laying it in the trench. The cable cores shall be tested for continuity, absence of cross phasing, Insulation Resistance between conductors to earth/armour and between conductors. The results should be recorded in presence of railways' representative. A composite cable layout plan on ferro-print or computerized print duly laminated in A-4 size should be submitted by the contractor to this office as well as site in-charge after laying of cable. Cables shall be supplied by railways at site engineer's stores. | — | — | — | 37,800 | |
| — | 1300.00 | — | — | ||
| Laying of cable on wall/cover shed/existing tray with MS clamp - The price shall cover for laying, testing and commissioning of LTUG armoured cable on wall/cover shed/in existing tray and its connection at both ends. The cable shall be tested with 500 Volt Megger before laying it in the tray. The cable cores shall be tested for continuity, absence of cross phasing, Insulation Resistance between conductors to earth/armour and between conductors. The results should be recorded in presence of railways' representative. A composite cable layout plan on ferro-print or computerized print duly laminated in A-4 size should be submitted by the contractor to site engineer and Divisional Office after laying of cable. | — | — | — | 40,300 | |
| — | 12.00 | — | — | ||
| Supply, fixing, testing and commissioning of 5.0-meter height G.I. Street Light octagonal pole, single arm complete with all accessories and foundation - The price shall cover for supply, erection and commissioning of 5.0 meter height single arm, G.I. street light octagonal pole as per the specifications given in Annexure-XXI of tender document. | — | — | — | 1,38,012 | |
| — | 12.00 | — | — | ||
| Supply, fixing, testing and commissioning of 5.0-meter height G.I. Street Light octagonal pole, double arm complete with all accessories and foundation - The price shall cover for supply, erection and commissioning of 5.0 meter height double arm, G.I. street light octagonal pole as per the specifications given in Annexure-XXI of tender document. | — | — | — | 1,62,480 | |
| — | 150.00 | — | — | ||
| Providing G.I. Earth wire, 8 SWG in PVC sleeve along with cable - The price shall cover for supply and laying of soft G.I. wire of 8 SWG covered with black coloured PVC sleeve of superior quality and laid along with PVC LTUG cable properly fixed and connecting earthing terminals of each panel. | — | — | — | 2,700 | |
| — | 150.00 | — | — | ||
| — | 18.00 | — | — | ||
| — | 1.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TenderDocument-BRC-EL-P-25-2601-04-26-27NEWGCC.pdf
ATTACHMENT
RailwayBoardsletterNo.2018_CE-I_CT_9dated04.06.18.pdf
ATTACHMENT
2024_06_03InstructionforincorporatingtheJPOCircularetc_ProvisionsintheTenderDocumentforallworksrequiringdiggingworksclosetoRly1.pdf for cable
ATTACHMENT
BankGuaranteeverification.pdf
ATTACHMENT
TechSpecsofEnergyEfficientLEDBasedLuminaire.pdf
ATTACHMENT
WesternRailwaysSpecificationsforACBLTPanelsMCCBandMCB.pdf
ATTACHMENT
2024_06_03InstructionforincorporatingtheJPOCircularetc_ProvisionsintheTenderDocumentforallworksrequiringdiggingworksclosetoRly1.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .