Loading…
Loading…
Tender Value
₹8.5 L
EMD Value
₹17,004
Closing Date
6 Oct 2026, 1:00 pm
Executive Engineer Paschim Med. Elecl. Div. PWDte.
Office of the Executive Engineer, Paschim Medinipur Electrical Division, P.W.Dte., Midnapore, Paschim Medinipur.
Replacement of Old Split and Floor Standing Type AC Machine installed at Ejlash of the District Judge, Paschim Medinipur - SITC Air Conditioning System. (1st ReTender)
2026_WBPWD_5018523_2
WBPWD/EE/PMED/NIT-02/e-T /2026-2027
Open Tender
ELECTRICAL WORKS ORG
Percentage
30 days
Midnapore, Paschim Medinipur
Please refer Tender documents.
3 documents required · 3 mandatory
₹17,004
23 Sept 2026
23 Sept 2026
8 Oct 2026
23 Sept 2026
6 Oct 2026
23 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr
(IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, aircirculation of following capacity with Scroll / rotary
compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambienttemperature).
Inverter Type - Cooling only 2.0 TR with 5 Star BEE Rating | 1 | Each | 57,396 | ₹57,396 |
| 2Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required . [DSR(E&M)2025/P240/31.14] | |||||
| 2.01 | 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm | 15 | Mtr | 256 | ₹3,840 |
| 2.02 | 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm | 15 | Mtr | 615 | ₹9,225 |
| 3Supplying, Installation, Testing and Commissioning of air cooled ducted split type air conditioning machine with each having a capacity and details as mentioned below suitable for operation on R 32/R-410A /R-407 Green refrigerant comprising of Scroll type compressor hermatically sealed complete with automatic capacity, safety switches, lubrication system with min 5 year (OEM) warranty for both compressor and Printed Circuit Board (PCB), Suitable capacity squirrel cage induction motor having class 'B' insulation suitable for operation on 415 + 10% volts, 50 Hz, A.C. supply for Blower motor, Necessary drive arrangement for blower motor, Matching Air cooled condenser with necessary fittings for refrigerant piping connections, necessary structural support for mounting condensers, Microprocessor based control panel complete with accessories, machine Isolation / disconnect switch, valves and accessories to inter connect compressor and condenser including pressure testing, vacuum. Necessary | |||||
| 3.01 | starters suitable for Indoor & outdoor unit complete with O/L, U/V, phase reversal protection, single phase preventors i/c copper conductor control and power cable and drain pipe of suitable size and length etc complete as required. The total cooling capacity/heating capacity of tested unit shall have a capacity as per relevant IS code. The lab testing reports as per IS: 8148 shall be submitted from National Accreditation Board for Testing and Calibration Laboratories (NABL) accredited as per ISO/International Electrotechnical Commission (IEC) 17025 standards / Central Power Research Institute (CPRI)/Electrical Research and Development Association (ERDA)with Original Equipment Manufacturer (OEM) etc. complete as per CPWD specification as required.
[DSR(E&M)2025/P243/32.3] | - | - | - | - |
| 3.02 | 8.5 TR (3.2 EER) [Non-Inverter] | 2 | Each | 1,64,444 | ₹3,28,888 |
| 4Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : [DSR(E&M)2025/P240/31.14] | |||||
| 4.01 | 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm | 20 | Mtr | 615 | ₹12,300 |
| 4.02 | 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm | 20 | Mtr | 1,157 | ₹23,140 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.59 MB
2911.pdf
Tender Documents • 0.50 MB
NIT022627.pdf
Other Document • 0.75 MB
BOQ_5162171.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .