Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical MAIN CHOWK TABAB TILLO JAMMU | JAMMU | JAMMU AND KASHMIR | 180001 | Admitted-Fee/PreQual/Technical |
| 2 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 3 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 4 | Admitted-Fee/PreQual/Technical 110 MINI SHOPPING COMPLEX NEHRU MARKET JAMMU | Admitted-Fee/PreQual/Technical |
Tender Value
₹3.4 L
EMD Value
₹7,000
Closing Date
1 Aug 2026, 4:00 pmClosed
XEN MH DIVISION GMCH JAMMU
XEN MH DIVISION GMCH JAMMU
Construction of Bio Medical Waste Management Shed and Dumping Station for General Waste at Govt. Psychiatric Diseases Hospital, Jammu.
2026_PWDJK_317264_1
MHDJ/e-NIT 138 of 2026-27
Open Tender
Repair and Maintenance Services
Turn-key
30 days
ovt. Psychiatric Hospital, Reshamghar
as per e nit
2 documents required · 2 mandatory
₹200
XEN MH DIVISION GMCH JAMMU
₹7,000
3 Aug 2026
22 Jul 2026
3 Aug 2026
22 Jul 2026
1 Aug 2026
27 Jul 2026
22 Jul 2026 - 1 Aug 2026
Select, Excess (+), Less (-) Less (-)
Tender Inviting Authority: Executive Engineer, Mechanical & Hospital Division GMCH Jammu.
Construction of Bio-Medical Waste Management Shed and Dumping Station for General Waste at Govt. Psychiatric Diseases Hospital, Jammu.
MHDJ/ MHDJ/e-NIT 138 of 2026-27 Dated: 21.07.2026 Due : 31.07.2026
Sl. No. Item Code / Make Quantity Units Estimated Rate Addition / Deduction Rate including GST to be quoted by the bidder Rs. P Currency Convertion against each Item Quoted Currency in INR / Other Currency Rebate on old parts in Percentage (%) if any Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category Net Cost of item Rs. P
1 Dismantling of Old Existing Shed by way of engaging 02 welders for 02 days. 4 no. Excess(+) Full Conversion INR
2 (2.8.1)Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed: All kinds of soil: 1x (18’-0’’+18’-0’’+ 12’-0’’+ 12’-0’’+ 12’-0’’) x2’-0”x 2’-0”=288 cft= 8.15 cum 8.15 cum Excess(+) Full Conversion INR
3 (4.4.7)Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centering and shuttering. All work upto plinth level with 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) 1x 72’-0’’x2’-0”x 0’-6” = 72cft= 2.04 cum 2.04 cum Excess(+) Full Conversion INR
4 (4.4.3)Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centering and shuttering. All work upto plinth level with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) a) 1x 72’-0’’x2’-0”x 1’-6” = 216 cft b) 1x 72’-0’’x1’-0”x 1’-0” = 72 cft Total =288 cft=8.16 cum 8.16 cum Excess(+) Full Conversion INR
5 (4.18)Providing and laying damp-proof Course 50 mm thick with cement concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and curing complete 1x 72’-0’’x1’-0” = 72 sft=6.69 sqm 6.69 sqm Excess(+) Full Conversion INR
6 (6.1.4)Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in Total = 1x 72’-0’’x 0’-9”x 10’-0” = 540 cft Deduct for Doors= 2x 0’-9’’x7’-0” = 10.5 cft Deduct for Exhaust Fans= 2’-0”x 2’-0”x2 = 8.0 cft 521.50 cft=14.77 cum 14.77 cum Excess(+) Full Conversion INR
7 (13.1.1)CEMENT PLASTER (IN FINE SAND) 12mm Cement plaster of mix: 1 : 4 ( 1cement : 4 fine sand) Qty. inside= 2(18’-0”+12’-0”)x10’-0”=600 sft Qty. outside= 2(18’-0”+12’-0”)x11’-0”=660 sft Deduct for Doors= 2x2x3’-3’’x7’-0” = 91 sft Deduct for Exhaust Fans= 2x2x2’-0”x 2’-0” = 16.0 sft Total=1153 sft=107.17 sqm 107.17 sqm Excess(+) Full Conversion INR
8 (12.13)Providing and fixing precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 1x 18’-0’’x14’-0” = 252 sft=23.42 sqm 23.42 sqm Excess(+) Full Conversion INR
9 (LMR) Providing and Fitting of Aluminium Doors with frame including all accessories required at site of size 2x3’-3”x7’-0”=45.50 sft as per the Direction of Engineer-in-charge 45.5 no. Excess(+) Full Conversion INR
10 (13.53) EXTERIOR FINISHING Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm),Qty. vide S.No. 7 i.e. 107.17 sqm 107.17 sqm Excess(+) Full Conversion INR
11 (10.16)Steel work in built up tubular Horizontal Square Tube Section trusses etc., including cutting ,hoisting , fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 10.16.1 Hot finished welded type tubes 7x18’-0”=126 Rft 9x14’-0”=126 Rft 252 Rft=76.82 [email protected] Kg/Rm=152.10 Kg 152.1 kg Excess(+) Full Conversion INR
12 (LMR) Providing & Installation of New Exhaust Fans-(18inch)-02No’s, as per required space at Biomedical Waste Shed of Govt. Psychiatric Diseases Hospital, Jammu by way of drilling/cutting of walls and making holes of required size, plastering of holes & making good for fitting of new heavy duty exhaust fans along with all other allied works. Job also includes Providing of electrical circuits in the said area by providing and laying of copper wire of requisite size, switches, tubelights, modules and sockets where ever required as per site conditions and making all connections and all the fans operational. The fans shall be of Usha/Havells/Bajaj/Crompton make Complete Job includes cost of material required, skilled labor, carriage and transportation of material to the site, any modifications required as per site conditions and all taxes etc. 1 job Excess(+) Full Conversion INR
13 (11.3.3)Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete 50 mm thick with 20mm nominal size stone aggregate. 18’-0”x14’-0”=252 sft=23.42 sqm 23.42 sqm Excess(+) Full Conversion INR
Total in Figures
Quoted Rate in Figures Select
Please Enable Macros to View BoQ information
stage.html
html • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.59 MB
BOQ_1038914.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .