Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.1 LAccepted-AOC 96 SECTOR 16 A CHANDIGARH 160015 | CHANDIGARH | CHANDIGARH | 160015 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹13.4 L+₹1.3 L (10.8%)Rejected-Finance PO BIRPARA DIST JALPAIGURI PIN 735204 WB | ALIPURDUAR | WEST BENGAL | 735204 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹13.6 L+₹1.5 L (12.7%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹18 L
EMD Value
₹36,000
Closing Date
9 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (SOUTH) BINNAGURI
GE (SOUTH) BINNAGURI, PO - BINNAGURI, DISTT - JALPAIGURI, PIN - 735232
REPAIR/REPLACEMENT TO SOLAR/GEYSERS WATER HEATERS AND FANS UNDER GE (SOUTH) BINNAGURI
2020_MES_394677_1
8401/E8
Open Tender
Electrical and Maintenance Works
Item Rate
150 days
GE (SOUTH) BINNAGURI
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE (SOUTH) BINNAGURI
₹36,000
Yes
27 Jan 2021
11 Nov 2020
10 Dec 2020
11 Nov 2020
9 Dec 2020
26 Nov 2020
60 days
Amount
Taking down of Solar water heating system of 300 ltrs per day capacity from its position after disconnecting water connections, and re - fixing /reassembling in position after repair and testing, complete all as specified and as directed. Note:- (a) Rate quoted by the contractor deemed to have been included making good of missing Nuts,Bolts and washers, unions, sockets, flanges, screws etc to make it full functional, (b) Descalling/desludging, cleaning and washing of solar panels,hot water pipes,copper tubes,hot and cold water Tanks by using appropriate chemicals and reassembling the panels including necessary welding of collector fins as required, (c) Painting to staging,solar panel frames,hot water tank frame using one coat of synthetic enamel paint including necessary preparation of surfaces complete, (d) any other materials/Parts need to be replaced(to be measured and paid as supplied only).
All as per item No-1 here in above but 200 Litre per day capacity -- Ditto --
All as per item No-1 here in above but 100 Litre per day capacity -- Ditto --
Supply only Solar energy collector panel made of Aluminium body with 5mm thick toughened glass complete with copper fins of capacity 300 litres per day as per existing make complete all as specified & directed.
Supply only Solar energy collector panel made of Aluminium body with 5mm thick toughened glass complete with copper fins of capacity 200 litres per day as per existing make complete all as specified & directed.
Supply only Solar energy collector panel gasket made out of Supirior quality Rubber to make system air tight,dust and water proof complete of capacity 200 litres per day as per existing make complete all as specified & directed.
Supply only Copper tubes of Solar energy collector panel with fins of existing dia/thickness/type of capacity 300 litres per day as per existing make including brazing using copper alloy brazing rod with existing inlet/outlet hot/cold water pipes to make the panel full working complete all as specified & directed.
Supply only compressed Glass wool(insulation materials) 48mm thick between Solar energy collector panel copper tubes frame and Aluminium body panel including securing it on panel by means of necessary adhessive complete all as specified & directed.
Supply only Solar energy collector panel manifold 1.40 mtr long, made out of 20mm dia copper tube having 1 No MS flange 74mm welded at each end duly drilled for Nuts,Bolts and washers as per existing make including welding of solar collector tubes with manifold complete all as specified & directed.
Supply only Hose pipe hot/cold water for solar system of suitable length as per existing size/Type/Make,complete with 02 Nos clamps complete all as specified & directed.
Supply only Auxilliary tank for make up Tank to reduce pressure of Solar water heating system complete all as specified & directed.
S&F in repair Electric back heater of 2 KW for Solar water Heating system with electrical connection complete all as specified & directed.
S&F in repair Electric back heater of 3 KW for Solar water Heating system with electrical connection complete all as specified & directed.
Descalling of Solar energy collector panel made of Aluminium body with 5mm thick toughened glass complete with copper fins of capacity 100/200/300 litres per day complete all as specified & directed.
Descalling of Hot water storage Tank of food grade stainless steel with heat exchanger of capacity 100 litres per day complete all as specified & directed. NOTE :- Write date of descalling with black/white synthetic enamal paint.
Descalling of Hot water storage Tank of food grade stainless steel with heat exchanger of capacity 200 litres per day complete all as specified & directed. NOTE :- Write date of descalling with black/white synthetic enamal paint.
Descalling of Hot water storage Tank of food grade stainless steel with heat exchanger of capacity 300 litres per day complete all as specified & directed. NOTE :- Write date of descalling with black/white synthetic enamal paint.
M&L compressed Glass wool(insulation materials) and covering with Aluminium sheet clading 25 gauge for 20mm bore GI hot water pipe complete all as specified & directed.
S&F of rotational moulded,multilayer HDPE water storage tank of 500 ltrs capacity(Cylindrical vertical with closed top) ISI (IS 12701-1996) marked fixed in position on existing places complete all as specified including 02 Nos 20mm dia full threaded GI tank niple, 20 mm dia brass ball valve with epoxy coated Aluminium rod with high density plastic float ball( of minium weight 210 gms ) including fixing of inlet, outlet & overflow pipe etc, complete all as specified and as directed.
S&F in repair 15 mm dia brass ball valve with epoxy coated Aluminium rod with high density plastic float ball (of minimum weight 210 gms ) and fly Nuts screwed for iron pipes complete all as specified and as directed.
S&F in repair 20 mm dia brass ball valve with epoxy coated Aluminium rod with high density plastic float ball( of minimum weight 210 gms ) and fly Nuts screwed for iron pipes complete all as specified and as directed.
S&F in repair gun metal gate or globe valve with iron wheel head ,screwed both ends for iron pipe and fixed 15 mm bore complete all as specified and directed.
S&F in repair gun metal gate or globe valve with iron wheel head ,screwed both ends for iron pipe and fixed 20 mm bore complete all as specified and directed.
M&L in repair compressed Glass wool(insulation materials) and covering with Aluminium sheet clading 25 gauge for 25 mm bore GI hot water pipe complete all as specified & directed.
Supply and filling distilled water to solar geyser for various capacity complete all as specified & directed.
Taking down geyser after disconnecting of existing water connection of 25 ltrs capacity from its position after disconnecting connection , opening of geyser to take out inner tank, soldering at two to three places to stop leakage and re - fixing in position after assembling and testing, complete all as specified and as directed. Note :-Collecting Geysers from AGE E/M store, opening of geyser to take out inner tank , soldering at two to three places to stop leakage if required,checking all spares and glass wool linning,replace the unserviceable spares,refixing serviceable spares including re-hanging after assembling and testing after completion complete all as specified and directed. Note:- Geysers under repair to be issued to the contractor through issue voucher and to be received back after repair through proper receipt voucher and contrctors challan only.Geysers to be collected from AGE E/M store for repair by the contractor at their own arrengement and to be deposited after repair duly tested.Spare parts except parts mentioned here in below will be measured and paid separately under respective items of BoQ as supplied only, cost of refixng of serviceable parts are deemed to have been included in the qouted rates:-
All as per item No-26 here in above but 35 Litre capacity -- Ditto --
All as per item No-26 here in above but 50 Litre capacity -- Ditto --
Supply only Heating element of 1.5 kw 230 volt to geyser including connection, complete all as specified and as directed.
Supply only Heating element of 2.0 kw 230 volt to geyser including connection, complete all as specified and as directed.
Supply only PVC Connection pipe 15 mm dia(bore) 45 cm long heavy duty with two Nos brass chromium plated union complete all as specified and as directed.
Supply only chromium plated copper flexible pipe connection heavy duty suitable for hot water supply from geyser with two nos brass chromium plated union, 450mm long complete all as specified and as directed.
Supply only new appurtus plate match to the existing one (any Make)with rubber gasket suitable for 25 ltrs geyser, complete all as specified and as directed.
Supply only new appurtus plate match to the existing one (any Make)with rubber gasket suitable for 35 ltrs geyser, complete all as specified and as directed.
Supply only new appurtus plate match to the existing one (any Make)with rubber gasket suitable for 50 ltrs geyser, complete all as specified and as directed.
Supply only new thermostat for 25/35/50 ltr matching to existing Make including all connection, complete all as specified and as directed.
Supply only new Stainless steel inner tank for geyser any make/type of 25 Litres capacity matching to exist one with all heat resistancee type rubber packings,Insulation materials(Glass wool), complete all as specified and as directed.
Supply only new Stainless steel inner tank for geyser any make/type of 35 Litres capacity matching to exist one with all heat resistancee type rubber packings, Insulation materials(Glass wool), complete all as specified and as directed.
Supply only new Stainless steel inner tank for geyser any make/type of 50 Litres capacity matching to exist one with all heat resistancee type rubber packings, Insulation materials(Glass wool), complete all as specified and as directed.
M&L point wiring complete for switch socket connection with FRLS PVC insulated unsheathed multistranded copper conductor of size 2.50 sqmm nominal cross sectional area single core drawn in and including 20mm dia 'heavy grade' PVC concealed conduits and fittings, including cutting chasing in brick wall n.exc 10cm width or girth(excluding ceiling surface), pressed steel concealed terminal switch boxes not less than 1.2mm thick of reqd size factory made duly painted inside and outside with two coats of black bituminous paint over one coat red oxide primer, 3mm thick plastic laminated sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers complete including 2.50 sqmm nominal cross sectional area PVC insulated unsheathed multistranded copper conductor green as earth wire connected to earth dolly with all accessories including cutting chasses,making good disturbed surfaces with CM(1:4) with treating the surfaces as per existing finishes complete all as specified and directed.
S&F of Switch socket combination multipurpose 2 in 1, 5 pin, 5 and 15 Amp,240V, flush type universal complete all as specified and directed .
S&F switch piano flush type 15/16 amp one way complete all as specified and directed .
Dismantling of existing unserviceable plug top and S&F 15 amp plug top complete with all connection, complete all as specified and as directed.
S&F in repair stop valves 15mm bore , cast copper alloy, chromium plated,fancy type ,screwed down, screwed both ends for iron pipe or for unions complete all as specified and directed.
S&F sub main wiring with single core FRLS PVC insulated unsheathed multistranded copper conductor conforming to IS 694 of size 4.0 sqmm nominal cross sectional area,1100 v grade and three run of 4.0 sqmm nominal cross sectional area FRLS PVC insulated unsheathed multistranded copper conductor green colour as continuous earth wire drawn in and including 20mm dia steel concealed conduits and fittings,complete including taking down of old sub main wiring all as specified and directed. NOTE:- One unit length shall measured as three run of main wire and one run of conduit & earth wire.
S&F in repair of sheet metal enclosure of epoxy powder coated, factory made for MCB's 240 volt 2 way single pole and neutral single door on wall with and including suitable flat iron clamps duly grouted/fixed flush in the wall using suitable lugs & glands including MCB single pole & neutral 6 to 32 amps, 240 volts, 'C' series, 10 KA breaking capacity complete all as specified and directed.
Supply in repair safety Nut for vaccum release valve from geyser of any make/type/capacity , matching to existing one with new Nut, complete all as specified and as directed.
Supply in repair hole fastener of geyser of any make/type/capacity , matching to existing one with new hole fastener 10mm dia, 100mm long including Nut,Bold and Washer complete all as specified and as directed.
Takingout unserviceable non return valve and S&F new non return valve(ISI marked) suitable for 15 mm dia GI pipe complete all as specified and as directed.
Supply only in repair Rubber gasket Kit from geyser of any make/type/capacity, matching to existing one with new Rubber gasket Kit, complete all as specified and as directed.
Fixing only in old geyser of any make /type /capacity in New position with hole fastenerand necessary Cement work as requiredincluding connection using existing pipes, complete all as specified and as directed.
Taking down fan of any type/make/sweep carefully from site, sealing cable and including all necessary arrangement,and depositing to AGE E/M store yard for repair work including re-hanging after repairing the same including provision of two core copper cable 0.75 Sqmm as required and testing after completioncomplete all as specified and directed. Note:- Ceiling Fans under repair to be issued to the contractor through issue voucher and to be received back after repair Through proper receipt voucher and contrctors challan only.Each ceiling Fan should be having MES No and the same shall invariably be mentioned in the MB with respective serial Nos.In absence of the same payment will not be allowed during running/Final payment.
M&L for rewinding of stator complete with super enameled copper wire of existing gauge/ weight of copper coil, quick varnishing, oiling, greasing insulating materials including replacement of worn out parts like u/s cotter pin, nut, screw, check nuts and bolts as required incl. cleaning of body, and testing of the following size of fans of any make complete all as specified and directed :- Note - Fans to be collected from AGE E/M store for repair by the contractor at their own arrengement and to be deposited after repair duly tested.Spare parts to be replaced here in below except rewinding will be measured and paid separately under respective items of schedule here in below as supplied only,cost of rifing of serviceable parts are deemed to have been included in the qouted rates:-
(a) Ceiling fan of any type and sweep
(b)exhaust fan of any type and sweep
Supply only following items to incorporate the item No. 52 to 54 as above :-
Gun Metal Bush for Bearing of any size for ceiling Fan
Ball Bearing of ceiling fan of any size of exactly similar as existing in fan complete all as specified and directed.
Capacitor 2.5 mfd complete all as specified and directed.
Capacitor 3.15 mfd complete all as specified and directed.
Connector Bakelite Two terminals each
Rubber Bush with MS Bolts,Nuts and Washers complete.
PVC Canopy for ceiling fan suitable for any sweep/ make as required incl. screw complete all as specified and directed.
Capacitor 4.0 mfd complete all as specified and directed
Taking down carefully old unserviceable aluminium point wiring (light, fan, socket or power) complete incl fittings such as switches, celling roses, etc and making good the disturbed surface complete all as specified and as directed.
M&L point wiring complete with FRLS PVC insulated unsheathed multistranded copper conductor of size 1.50 sqmm nominal cross sectional area single core drawn in and including 20mm dia 'heavy grade' PVC concealed conduits and fittings, including cutting chasing in brick wall n.exc 10cm width or girth(excluding ceiling surface), pressed steel concealed terminal switch boxes not less than 1.2mm thick of required size factory made duly painted inside and outside with two coats of black bituminous paint over one coat red oxide primer, 3mm thick plastic laminated sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers complete including 1.50 sqmm nominal cross sectional area PVC insulated unsheathed multistranded copper conductor green as earth wire connected to earth dolly with all accessories including making good disturbed surfaces with CM(1:4) with treating the surfaces as per existing finishes complete all as specified and directed.
(a) one ceiling fan/ exhaust fan point controlled by one way switch 5/6 amp.
(b) One socket out let 5/6 amps point on the independent board
S&F socket 2 in 1, 5 Pin, 5/6 amps, white finish flash type complete all as specified and directed.
S&F switch piano flush type 5/6 amps single pole one way all as specified.
S&F ceiling rose, bakelite, surface type, 220/240 volts, three terminals complete all as specified and directed.
S&F fan regulator, 5 stepped, electronic type, single phase, 400 watt, socket size incl connection complete complete all as specified & directed.
M&L for two single core (submain) PVC insulated cable with 1.5 sqmm nominal cross sectional area multistranded copper conductor conforming to IS 694 and one single core green PVC insulated 1.5 sqmm multistranded copper conductor conforming to IS 694 earth continuity cable drawn through non metallic, medium duty, rigid PVC conduit not less than 20 mm dia concealed in wall including all conduit and fixing accessories including cutting chases & making disturbed surfaces complete all as directed. Note :- (I) The cost for cutting, chases required shall deemed to be included in the quoted unit rate. (II) Two run of submain wire, one run of earth wire and one run of PVC conduit shall be measured one RM
SCHEDULE OF CREDIT Rate quoted by the Tenderer for this schedule should not be less than rate assessed by the department shown on estimated rate column for the respective items and total amount under col No 53 will be adjusted accordingly.
Old unserviceable solar panel
Old unserviceable copper tube
Old unserviceable solar energy collector panel manifold
Old unserviceable auxillary tank
Old unserviceable electrical heater back 2/3 KW
Old unserviceable hot water pipe
Old unserviceable PVC tank
Old unserviceable GATE/Ball valve
Old unserviceable heating element 1500 Watt
Old unserviceable heating element 2000 Watt
Old unserviceable PVC connection pipe
Old unserviceable chromium plated brass pipe
Old unserviceable apparatus plate 25 ltr capacity gyser
Old unserviceable apparatus plate 35 ltr capacity gyser
Old unserviceable apparatus plate 50 ltr capacity gyser
Old unserviceable thermostat 25/35/50 ltr capacity
Old unserviceable switch socket, plug
Old unserviceable 15 mm bore non return valve
Old unserviceable MCB of any type any capacity
Old unserviceable safty nut for pressure release valve
Old unserviceable steel tank of gyser 25 ltr capacity
Old unserviceable steel tank of gyser 35 ltr capacity
Old unserviceable steel tank of gyser 50 ltr capacity
Old unserviceable point wiring
Old unserviceable sheet metal encloser
Old unserviceable rewinding material of ceiling fan
Old unserviceable rewinding material of exhaust fan
Old unserviceable gun metal bush from ceiling/exhaust fan
Old unserviceable ball bearing from ceiling/exhaust fan
Old unserviceable capacitor2.5/3/4 MFD
Old unserviceable broken connector bakelite terminal
Old unserviceable rubber bush with MS bolts & nuts
Old unserviceable PVC canopy
Old unserviceable switch, socket, regulator, ceiling rose etc.
Old unserviceable flexible copper cable
CENTRAL ENGINEERING WORKS
Tirupati Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .