Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.0 LAccepted-AOC | ₹3.0 L | L1 | Accepted-AOC AOC |
| 2 | L2₹3.0 LRejected-Finance | ₹3.0 L | L2 | Rejected-Finance BID VALUE HIGH |
| 3 | L3₹3.0 LRejected-Finance | ₹3.0 L | L3 | Rejected-Finance BID VALUE HIGH |
| 4 | L4₹3.0 LRejected-Finance 000 RATH TALA UKHRA UKHRA UKHRA BARDHAMAN WEST BENGAL 713363 UDYAM WB 23 0008292 | PASCHIM BARDHAMAN | WEST BENGAL | 713363 | ₹3.0 L | L4 | Rejected-Finance BID VALUE HIGH |
Tender Value
₹3.0 L
EMD Value
₹5,987
Closing Date
10 Jun 2026, 12:05 pmClosed
Assistant Engineer,JESD,PWD,Jalpaiguri
O/o THE ASSISTANT ENGINEER, P.W.D. JALPAIGURI ELECTRICAL SUB-DIVISION PURTA BHAVAN, JALPAIGURI, PIN-735101
Electrical Repairing and Renovation work at South Berubari PHC, Jalpaiguri.
2026_WBPWD_5014049_1
WBPWD/AE/JESD/NIT 25e/T (2nd Call) of 2025-26
Open Tender
ELECTRICAL WORKS ORG
7 days
South Berubari PHC
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,987
1 Jul 2026
18 May 2026
12 Jun 2026
18 May 2026
10 Jun 2026
18 May 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Make- Havells/ Polycab/ RR Kabel/ KEI/Gloster) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch [Make: Legrand Myrius/ Crabtree Athena/ Schneider Livia/ L&K enGem] fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [only PVC Rigid Conduit on ceiling and remaining portion concealed] | |||||
| 1.1 | Average run 6 Mtr | 21 | Pts. | 935 | ₹19,635 |
| 1.2 | Average run 8 Mtr | 30 | Pts. | 1,149 | ₹34,470 |
| 2 | Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Make- Havells/ Polycab/ RR Kabel/ KEI/Gloster) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 6A 3 pin Modular type plug socket & switch [Make: Legrand Myrius/ Crabtree Athena/ Schneider Livia/ L&K enGem] on 4 Module GI switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works.
-On Board | 12 | Pts. | 231 | ₹2,772 |
| 3 | SUB-HEAD 2-- Plugs & Sockets
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket [Make: Legrand Myrius/ Crabtree Athena/ Schneider Livia/ L&K enGem] with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. | 9 | Each | 488 | ₹4,392 |
| 4 | Supply & Fixing 240 V, 2nos 6 A, 3 pin Modular type plug socket [Make: Legrand Myrius/ Crabtree Athena/ Schneider Livia/ L&K enGem] with 2 nos 6A Modular type switch, without plug top on 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. | 9 | Each | 788 | ₹7,092 |
| 5 | Supply & Fixing 240 V, 3 nos. 6 A, 3 pin Modular type plug socket with 3 nos. 6A & 1 no. 16 A, 3 pin Modular type plug socket with 1 no. 16A Modular type switch [Make: Legrand Myrius/ Crabtree Athena/ Schneider Livia/ L&K enGem], 20A Modular switch type SP MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy.connections with PVC Cu wire and earth continuity wire etc. | 4 | Each | 2,595 | ₹10,380 |
| 6 | Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket [Make: Legrand Myrius/ Crabtree Athena/ Schneider Livia/ L&K enGem], without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. | 1 | Each | 378 | ₹378 |
| 7 | Supply & Fixing 240 V, 25 A, Modular type starter [Make: Legrand Myrius/ Crabtree Athena/ Schneider Livia/ L&K enGem] with 25A Modular switch type DP MCB (C-Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. | 1 | Each | 839 | ₹839 |
| 8SUB-HEAD 3--- Supply of Light Fittings Supplying, installation, Testing & Commissioning of LED Industrial Batten light made of CRCA Sheet Body (Thickness ≥ 0.50 mm) and construction as per relevant IS, along with LED lamp (Opal finish polycarbonate housing with Aluminium end-cap), Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range 0o to 40o C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5%), life time (LED, Driver & electrical circuitary), of minimum 40000 Burning Hours, with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FR/FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 3 year OEM warranty. LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Fixing arrangement shall be as below: | |||||
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.59 MB
BOQ_5081975.xls
BOQ • 0.47 MB
Corii_of_Extend_e25_2nd_Call.pdf
PDF • 1.01 MB
Download all tender documents and submit your bid