Loading…
Loading…
Tender ID
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical Technically acceptable |
Tender Value
₹41.2 L
EMD Value
₹50,000
Closing Date
3 Mar 2026, 3:00 pmClosed
HOU(TP)
KMML,CHAVARA
Demolition, Earthwork excavation, Soling, PCC and RCC, Centering,shuttering and formwork, Red earth filling, Plastering, False ceiling and interior, Doors windows and joinery, plumbing and sanitary, Electrical work
2026_KMML_834789_1
EAF/CIV/1238/2025-2026(2), Dtd.14/01/2026
Open Tender
Civil Works - Buildings
Item Rate
240 days
KMML, CHAVARA
Refer Tender Documents
6 documents required · 6 mandatory
₹2,950
₹50,000
6 Apr 2026
17 Feb 2026
4 Mar 2026
17 Feb 2026
3 Mar 2026
17 Feb 2026
Brick work demolishing
Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In lime mortar with old mughal bricks
RCC demolition
Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.
Pcc demolishing
Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:4:8 or leaner mix ( including equivalent design mix)
Demolishing wooden door
Dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:Of area beyond 3 sq. metres
Dewatering with pump
Bailing out water/slush using pump above 5HP and up to 10 HP, including conveyance to site and erection, cost of fuel, lubrication oil and other stores, pay of staff etc complete. All deposits/slush shall be shifted to designated location with in 1km lead
Demolishing old iron ventilators
Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work ( Payment shall be made on the cross sectional area of R.C.C. or R.B work) as per direction of Engineer-in-charge.
Demolishing existing wooden partition
Dismantling wooden boardings in lining of walls and partitions, excluding supporting members but including stacking with in 50 metres lead:Upto 10 mm thick
Demolishing false ceiling
Dismantling roofing including ridges, hips, velleys and gutters etc., and stacking the material within 50 metres lead of :Asbestos cement Sheet
Excavation work
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
soling
Soling with rough stone of size 200 mm, well packed and filling voids with stone chips and required profile with hammer dressed stones having no side less than 15 cm, with minimum depth of 20 cm including preparing the bedding surface etc. all complete
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
RCC upto plinth level
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources)
Steel reinforcement work upto plinth level
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelMild steel and Medium Tensile steel bars
Solid block masonry upto plinth level
Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete
Bituminous painting
Painting with black anti- corrosive bitumastic paint of approved brand and manufacture to give an even shade:Two or more coats on new work
Red earth filling
Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge
RCC for column above plinth level
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Solid block masonry
Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc
RCC beam
Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources).
Steel reinforcement above plinth level
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Cold twisted bars
Plastering with 12mm cement plaster mix 1:4
Plastering with 12 mm cement plaster of mix: 1:4 (1 cement : 4 fine sand )
Ceiling
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum moisture resistant board
Shuttering for footing
Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
Shuttering for column above plinth level
Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
Shuttering for beams
Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
Shuttering for slab
Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
Shuttering for sunshade
Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges
Shuttering for stair
Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)
Applying SBR latex mixed plaster and applying bonding agent
Providing, mixing and applying SBR polymer (of approved make such as Nitobond SBR/SBR Reomix/Cera SBR Latex of M/s Fosroc/BASF/Cera Chem or Similiar respectively) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer as per manufactures specification) including surface cleaning and application of bonding slurry to the prepared surface for proper adhesion as per manufacturers specificationas and directions of Engineer in charge Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding /tapping with a blunt metal instrument of 12 mm average thickness including scaffoldings upto 4 m height
Thixotropic Non shrink mortar
Providing and applying single component fibre reinforced thixotropic non shrink repair mortar such as BASF EMACO S48CT or FOSROC/BOSTIK product for columns, beams, slabs and other structural members with 4 ltrs of potable water per 25kg of product, mixing by heavyduty, slow speed drill with spiral mixing paddle or a Pan type mixers etc. after pouring the water in a mixing vessel, mixed material shall be applied both by trowel or spray application and finished to get a uniform thickness and finish and all works as per manufactures specifications and as directed by the Engineer in charge, including curing, cost of materials, labour, scaffolding upto a height of 4 mtr, conveyance etcThe work shall be carried by an agency having sufficient experience and should ensure a guarantee of 5years. Only skilled and experienced persons shall be employed for this purpose.
Supply and laying first quality vitrified tiles of size 1200*600
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including spacers 3mm and grouting the joints with epoxy which shall be paid extra., complete.Size of Tile 1200x600 mm
Epoxy grouting
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mm or nearest
providing & fixing anti skid floor tile at toilet
Providing and fixing premium quality ceramic digital anti-skid floor tiles of make<br>Kajaria/Nitco/Simpolo/Cera or approved brand conforming to IS : 15622 (thickness to be<br>specified by the manufacturer), in all colours, shades of size matching to wall tiles or as approved by<br>Engineer -in-Charge, over 12 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) with tile spacers 3mm and jointing with epoxy joint fillers with pigment of matching shade of approved brand in approved pattern<br>with two or more desgin tiles complete.
Providing & fixing premium quality ceramic digital wall tile
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in- Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and including spacers 3mm and grouting the joints with epoxy which shall be paid extra., complete
painting
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
Window grill
Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc
Aluminium Frame work for Doors windows and partitions
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions,i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)
Shutter for doors and windows
For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)
UV sheet for doors
Providing and fixing 4 mm thick UV sheet in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws , UV Sheet finished in two diffrent colours and complete as per architectural drawings and directions of Engineer - in- Charge
Glass
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm)
Lock for doors
Providing and fixing Brass100 mm mortice latch and lock with 6 levers without pair of handles ( best make of approved quality ) for aluminum doors including necessary cutting and making good etc. complete
Hinges
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:100 mm
Handles
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:100 mm
Tower bolts
Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : (Copper oxidized as per IS : 1378)250x10 mm
FRP door frame
Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of crosssection 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.
FRP door shutter
Providing and fixing to existing door frames.30 mm thick Fiberglass Reinforced Plastic (F.R.P) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used all filler material throughout the hollow panel, casted monoolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS : 14856, complete as per direction of Engineerin-charge.
25 mm PVC concealed
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 25 mm pipe 10kgf /cm2
32mm PVC concealed
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 10Kgf/cm2
50mm PVC concealed
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 6 kgf/cm2
63mm PVC concealed
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work including cutting chases and making good the wall etc. 63 mm pipe 6 Kgf/cm2
32 mm pvc pipe exposed on wall
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 6 Kgf/cm2 - External work - Exposed on wall
50mm pvc pipe exposed on wall
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 6Kgf/cm2 - External work - Exposed on wall
110mm pvc pipe trenching and refilling
Providing and fixing PVC pipes includes joints of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in CHarge. 110 mm dia 4 Kg/cm2
63mm dia elbow
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -63 dia 45 degree Elbow
63mm 45 degree elbow
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -63 dia 45 degree Elbow
63 dia pvc door elbow
Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Door Elbow
63 dia tee
Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes including jointing with PVC solvent cement - 63x63x63 mm dia Tee
63mm dia pvc bend
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Bend
63mm dia door tee
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -63x63x63 mm dia Door Tee
63mm dia vent cowl
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia vent cowl
110-63mm pvc reducer
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110x63 mm dia Reducer
63x50mm pvc reducer
Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63x50 mm dia Reducer
63mm dia socket/coupling
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia End cap
63mm dia coupling
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia End cap
110mm dia elbow
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow
110mm dia 45 degree elbow
Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia 45 degree Elbow
110 mm dia door elbow
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement-110 mm dia Door Elbow
110mm dia bend
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend
110mm dia tee
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes including jointing with PVC solvent cement 110x110x110 mm dia Tee
110mm dia door tee
Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x110x110 mm dia Door tee
110mm dia socket/coupling
Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia Socket/ coupling
GM ball valve
Providing and fixing GM ball valve of approved quality (screwed end) :<br>25 mm nominal bore
Providing and fixing CP brass bib cock long body
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore
Providing and fixing CP brass stop cock
Providing and fixing C.P brass stop cock ( concealed) of standard design and of approved make conforming to IS: 893115 mm nominal bore
CP brass angle valve
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore
PVC ball valves
Providing and fixing PVC ball valve (ISI marked) of approved brand for Rigid PVC pipes, including jointing with PVC solvent cement:<br>25mm nominal bore.
CP brass shower rose
Providing and fixing C.P. brass shower rose with arm of 15 or 20 mm inlet:<br>100 mm diameter
SS soap Dish
Supplying and fixing Stainless steel soap dish including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.
Towel rod
Supplying and fixing CP Towel rod 45cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-incharge.
Health faucet
Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge
CP gratings
Providing and fixing CP grating of approved quality.<br>Rectangular type with openable circular lid<br>150 mm nominal size square 100 mm diameter of the inner hinged round grating
Floor trap
Providing and fixing PVC moulded Floor trap for sanitary pipelines, including jointing PVC pipes with PVC solvent cement and filling gaps with cement groutFloor trap 4 way/3 way
Labour charge
Miscellaneous labour
Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved epoxy primer and 2 or more coats of epoxy paint, including welding and bolted with special shaped washers etc. complete
Steel reinforcement paint
Providing and applying anti corrosive Nitozinc primer/Cera cte SP CI/ protectosil CIT, two or more coats, over the steel reinforcement as per the manufactures specification including scaffolding upto height 4 mtr and as directed by Engineer-incharge. The product shall be applied on the reinforcement surface after throughly cleaning. painted area of steel shall be considered for payment
Orissa pattern W.C. pan
Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked black solid plastic seat and lid
providing & fixing mirror
Providing and fixing mirror of superior glass ( of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 453x357 mm
providing & fixing wash basin
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 450x300 mm with single 15 mm C.P. brass pillar tap
Tap pvc PTMT
Providing and fixing PTMT bib cock of approved quality and colour.15 mm nominal bore, 86 mm long, weighing not less than 88 gms
Providing new septic tank
Supplying and installing ready made RCC Septic tank including the cost of carriage, trenching, placing at the level below ground level as specified as per the direction of engineer in charge incl supply of CC/Sand/06mm aggregate for the preparation of bed) 35 to 50 flush capacity
SUPPLY PART DISTRIBUTION BOARDS
Supply of 63A, 3 phase 415V 4 way Verical Distribution board In sheet steel enclosure with double door and detachable gland plate, complete with cable entry adaptor box, tinned copper busbars, neutral link, earth bar, din bar, knockouts, interconnections, earth studs etc. as required For surface mounting With 63A, 4 pole MCCB as incomer and 1 No.s of 40A 4 pole MCCBs and 2 No. of 32A 4 pole MCCB as outgoing (Including required dummy to close the vaccant spaces) Make of DB: Standard/Havells/ABB/Siemens/Hager/Schneider Make od MCCB/MCB: Standard/Havells/ABB/Siemens/Hager/Schneider
Supply of 40A, 3 phase 415V 4 way Horizontal Distribution board In sheet steel enclosure with double door and detachable gland plate, complete with cable entry adaptor box, tinned copper busbars, neutral link, earth bar, din bar, knockouts, interconnections, earth studs etc. as required For surface mounting With 40A, 3 phase 4P MCB & 40A, 30mA 3 phase RCCB as incomer and 9 No.s of 20A SP MCBs as outgoing Make of DB: Standard/Havells/ABB/Siemens/Hager/Schneider Make od MCCB/MCB/RCCB: Standard/Havells/ABB/Siemens/Hager/Schneider
Supply of 25A, 3 phase 415V 6 way Horizontal Distribution board In sheet steel enclosure with double door and detachable gland plate, complete with cable entry adaptor box, tinned copper busbars, neutral link, earth bar, din bar, knockouts, interconnections, earth studs etc. as required For surface mounting With 25A, 3 phase 4P MCB & 25A, 30mA 3 phase RCCB as incomer and 12 No.s of 6A SP MCBs as outgoing (Including required dummy to close the vaccant spaces) Make of DB: Standard/Havells/ABB/Siemens/Hager/Schneider Make od MCCB/MCB/RCCB: Standard/Havells/ABB/Siemens/Hager/Schneider
LIGHTING AND WIRING. LIGHT FIXTURES AND FANS, SWITCHES AND SOCKETS
Supply of LED downlight round (Approximate cutout dia 15cm), 10W (Approximate), 230V, 50Hz AC supply, with spring buckle for concealed false ceiling mounting, Lumen efficacy: 100 Lumens/W or above, Lumens: 1000 Lumens or above, THD: 15% or less, PF: 0.90 or above, CRI: 80 or above, Colour temperature: Cool White(5500-6500K), IP: 20 or above, Warranty: Full warranty of 1 year or above
Supply of LED downlight round (Approximate cutout dia 20cm), 20W (Approximate), 230V, 50Hz AC supply, with spring buckle for concealed false ceiling mounting, Lumen efficacy: 100 Lumens/W or above, Lumens: 2000 Lumens or above, THD: 15% or less, PF: 0.90 or above, CRI: 80 or above, Colour temperature: Cool White(5500-6500K), IP: 20 or above, Warranty: Full warranty of 1 year or above
Supply of LED wall light, 10W (Approximate), 230V, 50Hz AC supply, with spring buckle for concealed false ceiling mounting, Lumen efficacy: 100 Lumens/W or above, Lumens: 1000 Lumens or above, THD: 15% or less, PF: 0.90 or above, CRI: 80 or above, Colour temperature: Cool White(5500-6500K), IP: 20 or above, Warranty: Full warranty of 1 year or above
Supply of LED mirror light, 10W (Approximate), 230V, 50Hz AC supply, with spring buckle for concealed false ceiling mounting, Lumen efficacy: 100 Lumens/W or above, Lumens: 1000 Lumens or above, THD: 15% or less, PF: 0.90 or above, CRI: 80 or above, Colour temperature: Cool White(5500-6500K), IP: 20 or above, Warranty: Full warranty of 1 year or above
Supply of LED tube light batten, 4 feet, 20W (Approximate), 230V, 50Hz AC supply, Lumen efficacy: 100 Lumens/W or above, Lumens: 2000 Lumens or above, THD: 15% or less, PF: 0.90 or above, CRI: 80 or above, Colour temperature: Cool White(5500-6500K), IP: 20 or above, Warranty: Full warranty of 1 year or above
Supply of Exhaust Fan, 225 mm sweep Make:USHA/CROMPTON/BAJAJ/ORIENT/KHAITHAN/HAVELLS
Supply of CEILING FAN MOTOR TYPE: BLDC 230 V, 50 HZ, AC, 1200 MM SWEEP WITH REMOTE CONTROL AND ALL ACCESSORIES STAR RATING: 5 MAKE: ATOMBERG/CROMPTON/HAVELLS/ORIENT/LUCAS/HALONIX.
Supply of Electric calling bell, 230V, 50Hz Make:Anchor/havells/L&T/Legrand
Supply of Bell switch, for 1 module, modular, Make: Legrand, Havells, Anchor, ABB, Honeywell
Supply of 6A switch, for 1 module, modular, Make: Legrand, Havells, Anchor, ABB, Honeywell
Supply of 25A switch, for 1 module, modular, Make: Legrand, Havells, Anchor, ABB, Honeywell
Supply of 6A Socket, for 2 module, modular, Make: Legrand, Havells, Anchor, ABB, Honeywell
Supply of 25A Socket, for 2 module, modular, Make: Legrand, Havells, Anchor, ABB, Honeywell
Supply of RJ11 Socket, for 1 module, modular, Make: Legrand, Havells, Anchor, ABB, Honeywell
Supply of RJ45 Socket, for 1 module, modular, Make: Legrand, Havells, Anchor, ABB, Honeywell
Supply of Concealed box, Plate and frame for 2 module, modular, Make: Legrand, Havells, Anchor, ABB, Honeywell
Supply of Concealed box, Plate and frame for 3 module, modular, Make: Legrand, Havells, Anchor, ABB, Honeywell
Supply of Concealed box, Plate and frame for 4 module, modular, Make: Legrand, Havells, Anchor, ABB, Honeywell
Supply of Concealed box, Plate and frame for 6 module, modular, Make: Legrand, Havells, Anchor, ABB, Honeywell
Supply of Concealed box, Plate and frame for 12 module, modular, Make: Legrand, Havells, Anchor, ABB, Honeywell
Modular type wiring
Supply of materials required for copper point wiring for lights, fans and exhaust fan in recessed PVC medium gauge conduit with modular type switch - using 1.5 sq. mm. PVC insulated copper conductor stranded cable in recessed PVC conduit including loop earthing using 1.5 sq. mm. PVC insulated copper wire as required, with modular type switch with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete. (Excluding supply of Fans, Exhaust fans, Lights, Concealed mounting boxes, Plates and Frames, Switches and Sockets) (Cable make: UNIVERSAL/ECI/CCI/SARK/NICCO/POLYCAB/PARAGON/OMEGA/INCAB/FINOLEX/ TORRENT/PREMIER/LAPP/GOVIND/GLOSTER/HAVELLS/ORBIT/RR CABEL/EMPIRE.)
Supply of materials required for copper point wiring for 25A sockets in recessed PVC medium gauge conduit with modular type switch - using 2.5 sq. mm. PVC insulated copper conductor stranded cable in recessed PVC conduit including loop earthing using 2.5 sq. mm. PVC insulated copper wire as required, with modular type switch with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete. (Excluding supply of Concealed mounting boxes, Plates and Frames, Switches, Sockets) (Cable make: UNIVERSAL/ECI/CCI/SARK/NICCO/POLYCAB/PARAGON/OMEGA/INCAB/FINOLEX/ TORRENT/PREMIER/LAPP/GOVIND/GLOSTER/HAVELLS/ORBIT/RR CABEL/EMPIRE.)
Supply of materials required for copper point wiring for calling bell in recessed PVC medium gauge conduit with modular type switch - using 1.5 sq. mm. PVC insulated copper conductor stranded cable in recessed PVC conduit including loop earthing using 1.5 sq. mm. PVC insulated copper wire as required, with modular type switch with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete. (Excluding supply of Concealed mounting boxes, Plates and Frames, Switches, Sockets) (Cable make: UNIVERSAL/ECI/CCI/SARK/NICCO/POLYCAB/PARAGON/OMEGA/INCAB/FINOLEX/ TORRENT/PREMIER/LAPP/GOVIND/GLOSTER/HAVELLS/ORBIT/RR CABEL/EMPIRE.)
Supply of materials required for circuit wiring for RJ11 in PVC medium gauge conduit with modular type switch - using telephone cable (twin flat copper PVC insulated, 2 x 0.5 sq mm, ISI marked, Make: Finolex, Anchor, V-guard, Traco, Sark, Orbit, Polycab) in recessed PVC conduit with modular type socket with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete. (Excluding supply of Concealed mounting boxes, Plates and Frames, Sockets)
Supply of materials required for circuit wiring for RJ45 sockets in PVC medium gauge conduit with modular type switch - using CAT 6 UTP cable (Make: D-link, Finolex, Polycab, Lapp) in recessed PVC conduit with modular type socket with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete. (Excluding supply of Concealed mounting boxes, Plates and Frames, Sockets)
Supply of materials required for wiring for Smoke Detectors in recessed PVC medium gauge conduit - using 3 x 1 sq. mm. PVC insulated copper cable in recessed PVC conduit with modular type socket with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete. (Excluding supply of Smoke detector) (Cable make: UNIVERSAL/ECI/CCI/SARK/NICCO/POLYCAB/PARAGON/OMEGA/INCAB/FINOLEX/ TORRENT/PREMIER/LAPP/GOVIND/GLOSTER/HAVELLS/ORBIT/RR CABEL/EMPIRE.)
Supply of materials required for copper point wiring for lights, fans and exhaust fan in recessed PVC medium gauge conduit with modular type switch - using 1.5 sq. mm. PVC insulated copper conductor stranded cable in srecessed PVC conduit including loop earthing using 1.5 sq. mm. PVC insulated copper wire as required, with modular type switch with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete. (Excluding supply of Fans, Exhaust fans, Lights, Concealed mounting boxes, Plates and Frames, Switches and Sockets). (For exceeding 5 meter point wiring. Tthis will be in addition to point wiring rate above). (Cable make: UNIVERSAL/ECI/CCI/SARK/NICCO/POLYCAB/PARAGON/OMEGA/INCAB/FINOLEX/ TORRENT/PREMIER/LAPP/GOVIND/GLOSTER/HAVELLS/ORBIT/RR CABEL/EMPIRE.)
Supply of materials required for copper point wiring for 25A sockets in recessed PVC medium gauge conduit with modular type switch - using 2.5 sq. mm. PVC insulated copper conductor stranded cable in recessed PVC conduit including loop earthing using 2.5 sq. mm. PVC insulated copper wire as required, with modular type switch with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete. (Excluding supply of Concealed mounting boxes, Plates and Frames, Switches, Sockets). (For exceeding 5 meter point wiring. This will be in addition to point wiring rate above). (Cable make: UNIVERSAL/ECI/CCI/SARK/NICCO/POLYCAB/PARAGON/OMEGA/INCAB/FINOLEX/ TORRENT/PREMIER/LAPP/GOVIND/GLOSTER/HAVELLS/ORBIT/RR CABEL/EMPIRE.)
Supply of materials required for copper point wiring for calling bell in recessed PVC medium gauge conduit with modular type switch - using 1.5 sq. mm. PVC insulated copper conductor stranded cable in recessed PVC conduit including loop earthing using 1.5 sq. mm. PVC insulated copper wire as required, with modular type switch with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete. (Excluding supply of Concealed mounting boxes, Plates and Frames, Switches, Sockets). (For exceeding 5 meter point wiring, this will be in addition to point wiring rate above). (Cable make: UNIVERSAL/ECI/CCI/SARK/NICCO/POLYCAB/PARAGON/OMEGA/INCAB/FINOLEX/ TORRENT/PREMIER/LAPP/GOVIND/GLOSTER/HAVELLS/ORBIT/RR CABEL/EMPIRE.)
Supply of materials required for Copper circuit wiring in PVC conduit - Circuit Wiring with 1.5 sq.mm PVC insulated, copper conductor, stranded cable in recessed PVC conduit along with 1 no. 1.5 sq. mm. PVC insulated copper wire for loop earthing as required.
Supply of materials required for Copper circuit wiring in PVC conduit - Circuit Wiring with 2.5 sq.mm PVC insulated, copper conductor, stranded cable in recessed PVC conduit along with 1 no. 2.5 sq. mm. PVC insulated copper wire for loop earthing as required.
Supply of 10 pair telephone junction box and accessories for surface mounting, Make: Syntex, Krone
INSTALLATION PART Modular type wiring and Installation
Installation, testing and commissioning of LED downlight of all types complete with all accessories etc. in false ceiling including connection with 1.5 sq.mm PVC insulated copper conductor single core cable etc. as required.
Installation of ceiling fans, making connections, testing and commissioning etc. with 1.5 sq.mm PVC insulated copper conductor single core cable etc. as required
Installation of exhaust fan upto 300 mm sweep in the existing opening including making the holes to suit the size of the above fan making good the damage, connections, testing and commissioning etc. with 1.5 sq.mm PVC insulated copper conductor three core cable etc. as required
Installation, testing and commissioning of LED tube lights, wall lights and mirror lights of all types complete with all accessories etc. including connection with 1.5 sq.mm PVC insulated copper conductor single core cable etc. as required.
Installation of calling bell at DCW room, making connections, testing and commissioning etc. with 1.5 sq.mm PVC insulated copper conductor single core cable etc. as required
Installation, testing and commissioning of Smoke Detectors complete with all accessories etc. including connection with 1.5 sq.mm PVC insulated copper conductor three core cable etc. as required.
Fixing of 6/25 amps modular type sockets, switches, bell switches, RJ11 and RJ45 modular sockets (other than included in point wiring) with front plate in surface or in recess including providing and fixing suitable size metal box, inter connections etc as required.
Copper point wiring in PVC medium gauge conduit with modular type switch - Wiring for light point/fan point/exhaust fan point using 1.5 sq. mm. PVC insulated copper conductor stranded cable in recessed PVC conduit including loop earthing using 1.5 sq. mm. PVC insulated copper wire as required, with modular type switch with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete.
Copper point wiring in PVC medium gauge conduit with modular type switch - Wiring for socket point using 2.5 sq. mm. PVC insulated copper conductor stranded cable in recessed PVC conduit including loop earthing using 4 sq. mm. PVC insulated copper wire as required, with modular type switch with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete.
Copper point wiring in PVC medium gauge conduit with modular type switch - Wiring for calling bell point using 1.5 sq. mm. PVC insulated copper conductor stranded cable in recessed PVC conduit including loop earthing using 1.5 sq. mm. PVC insulated copper wire as required, with modular type switch with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete.
Copper point wiring in PVC medium gauge conduit for Smoke Detector - Wiring for smoke detector point using 1/1.5 sq. mm. PVC insulated copper conductor stranded cable in recessed PVC conduit including loop earthing using 1/1.5 sq. mm. PVC insulated copper 3 core cable as required
Copper point wiring for lights, fans and exhaust fan in recessed PVC medium gauge conduit with modular type switch - using 1.5 sq. mm. PVC insulated copper conductor stranded cable in srecessed PVC conduit including loop earthing using 1.5 sq. mm. PVC insulated copper wire as required, with modular type switch with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete. (Excluding supply of Fans, Exhaust fans, Lights, Concealed mounting boxes, Plates and Frames, Switches and Sockets). (For exceeding 5 meter point wiring. Tthis will be in addition to point wiring rate above).
Copper point wiring for 25A sockets in recessed PVC medium gauge conduit with modular type switch - using 2.5 sq. mm. PVC insulated copper conductor stranded cable in recessed PVC conduit including loop earthing using 2.5 sq. mm. PVC insulated copper wire as required, with modular type switch with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete. (Excluding supply of Concealed mounting boxes, Plates and Frames, Switches, Sockets). (For exceeding 5 meter point wiring. This will be in addition to point wiring rate above).
Copper point wiring for calling bell in recessed PVC medium gauge conduit with modular type switch - using 1.5 sq. mm. PVC insulated copper conductor stranded cable in recessed PVC conduit including loop earthing using 1.5 sq. mm. PVC insulated copper wire as required, with modular type switch with non metallic inner and outer cover (inner and outer plate) in suitable metal boxes etc. as required to complete. (Excluding supply of Concealed mounting boxes, Plates and Frames, Switches, Sockets). (For exceeding 5 meter point wiring, this will be in addition to point wiring rate above).
Copper circuit wiring in PVC conduit - Circuit Wiring with 1.5 sq.mm PVC insulated, copper conductor, stranded cable in recessed PVC conduit along with 1 no. 1.5 sq. mm. PVC insulated copper wire for loop earthing as required.
Copper circuit wiring in PVC conduit - Circuit Wiring with 2.5 sq.mm PVC insulated, copper conductor, stranded cable in recessed PVC conduit along with 1 no. 2.5 sq. mm. PVC insulated copper wire for loop earthing as required.
LAN circuit wiring in PVC conduit - Circuit Wiring with UTP/Ethernet cable in recessed PVC conduit as required.
Telephone circuit wiring in PVC conduit - Circuit Wiring with two core telephone cable in recessed PVC conduit as required.
DB installation and Cabling
Installation, testing and commissioning of 63A, 3 phase 415V 4 way Verical Distribution board In sheet steel enclosure with double door and detachable gland plate, complete with cable entry adaptor box, tinned copper busbars, neutral link, earth bar, din bar, knockouts, interconnections, earth studs etc. as required For surface mounting With 63A, 4 pole MCCB as incomer and 1 No.s of 40A 4 pole MCCBs and 2 No. of 32A 4 pole MCCB as outgoing (Including required dummy to close the vaccant spaces) Make of DB: Standard/Havells/ABB/Siemens/Hager/Schneider Make od MCCB/MCB: Standard/Havells/ABB/Siemens/Hager/Schneider
Installation, testing and commissioning of 40A, 3 phase 415V 4 way Horizontal Distribution board In sheet steel enclosure with double door and detachable gland plate, complete with cable entry adaptor box, tinned copper busbars, neutral link, earth bar, din bar, knockouts, interconnections, earth studs etc. as required For surface mounting With 40A, 3 phase 4P MCB & 40A, 30mA 3 phase RCCB as incomer and 9 No.s of 20A SP MCBs as outgoing Make of DB: Standard/Havells/ABB/Siemens/Hager/Schneider Make od MCCB/MCB/RCCB: Standard/Havells/ABB/Siemens/Hager/Schneider
Installation, testing and commissioning of 25A, 3 phase 415V 6 way Horizontal Distribution board In sheet steel enclosure with double door and detachable gland plate, complete with cable entry adaptor box, tinned copper busbars, neutral link, earth bar, din bar, knockouts, interconnections, earth studs etc. as required For surface mounting With 25A, 3 phase 4P MCB & 25A, 30mA 3 phase RCCB as incomer and 12 No.s of 6A SP MCBs as outgoing (Including required dummy to close the vaccant spaces) Make of DB: Standard/Havells/ABB/Siemens/Hager/Schneider Make od MCCB/MCB/RCCB: Standard/Havells/ABB/Siemens/Hager/Schneider
Laying, dressing and clamping of following cables through exsisting trays / structures / racks / columns / walls etc to the new DB .Cable shall be supplied by KMML. All other materials required for clamping are under the scope of contractor.
(3.5 x 25 to 3.5 x 50) sq. mm AYFY/XLPE cable
Glanding and termination at DB's side of PVC cable using DC glands/ lugs including supply of cable glands, lugs, aluminium crimping sockets, nuts bolts etc. required for this work. Gland earthing as per standards shall be done by the contractor.
(3.5 x 25 to 3.5 x 50) sq. mm AYFY/XLPE cable
Telephone switch relocation
Installation, testing and commissioning of 10 pair telephone junction box and accessories for surface mounting, Make: Syntex, Krone
Approval from Electrical Inspectorate.
Preparation of all electrical drawings and obtainig statutory approval from electrical inspectorate for the new DBs
stage.html
html • 0.02 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.27 MB
BOQ_1404406.xls
BOQ • 0.45 MB
am.pdf
Other Document • 0.26 MB
td.pdf
Tender Documents • 6.18 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .