Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 LAccepted-AOC | L1 | Accepted-AOC L1 |
Tender Value
₹1.7 L
EMD Value
₹4,134
Closing Date
19 Jan 2023, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER
O/o the Executive Engineer, LSGD Division, Kakkanad, Ernakulam.
Refer tender document
2022_LSGD_538085_2
ET 300/DP EKM/EE/LSGD/22-23
Open Tender
Electrical Works
Item Rate
120 days
Kakkanad
Please refer Tender documents.
7 documents required · 7 mandatory
₹555
Yes
₹4,134
Yes
31 Mar 2023
11 Jan 2023
23 Jan 2023
11 Jan 2023
19 Jan 2023
11 Jan 2023
Amount
Providing Pump Set -
90.2.1.3:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control light point without ceiling rose - Short point
90.2.1.6:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Combined plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of light points
OD230389/2022-2023:Supply and fixing angle / straight brass lined skirt type, backelite batten holder with 7/9W LED and plastic shade and giving connection etc as required
OD230390/2022-2023:Supply, conveyance, erection, testing and commissioning of 10 HP /12.5 HP , Radial Flow open well submersible pump set working on 3 phase 415 V, with head range 40/160 mtr and discharge range of 420/60 LPM. Delivery pipe Size 2"(TEXMO-Aquatex RS 49/16 ) suitably mounted on proposed 50 mm GI pipe etc as required or equivalent make.
OD230391/2022-2023:Supply and providing BCH make Star Delta Starter control with protection against overload, single phasing, phase reversal & severe unbalanced voltages conditions, in accordance with latest IS/IEC 60947-4-1 specifications suitable for 10 HP/ 12.5 HP submersible motor pump set complete duly internally connected
90.6.6.4:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.6 sq mm
90.14.24.5:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.5 KVAr, 3 phase, 440 V, delta connected standard duty Metalised Poly Propylene Cylinderical Type Capacitor suitable for direct connection to motors.
OD230392/2022-2023:Supply and providing Cable Joint Tape etc. as required.
OD230393/2022-2023:Supply and Providing 50 mm or nearest size UPVC Adaptor Set DC CI with accessories etc
OD230394/2022-2023:Supply and fixing 50mmx 12" GI Barrel nipple
OD230395/2022-2023:Supply and fitting 50 mm or nearest size GI Bend on pumping main with flanges welded and nut bolt etc on pumping main.
OD230396/2022-2023:Supply and fitting 50 mm or nearest size Sluice valve on existing GI pipe with flanges etc
OD230397/2022-2023:Supply and fitting 50 mm Non Return valve using required bolt and nut and flange etc
OD230398/2022-2023:Supply and providing clamp set CI 50mm Heavy
OD230399/2022-2023:Supply and fixing 25mm Ball Valve with 15mm nipple and 15mm socket duly welded as required
OD230400/2022-2023:S&I of Pressure meter with accessories and stopper valve etc on delivery side of 50 mm GI pipe line as required
OD230401/2022-2023:Supply and fitting 50 mm GI socket etc. as required.
OD230402/2022-2023:Supply and Providing 50 mm GI pipe (Medium class) Cutting threading welding and with accessories etc
OD230403/2022-2023:Supply and provide NYLON ROPE MAXIMA LG 12MM for hanging submersible pump set
OD230404/2022-2023:Supply and providing Cotton waste etc. as required.
OD230405/2022-2023:Supply and providing Shellac 50 ml etc. as required.
OD230406/2022-2023:Supply and fixing 20mm corrugated flexible pvc conduit
90.6.10.2:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm
1.17.31:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 6 sq. mm
90.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
OD230407/2022-2023: Earthing with G.I. earth plate 600mm X600 mm X 6 mm thick with watering pipe 1.7 metre long and test joint using 2 nos ,25x3mm GI Strip with sufficient drilled holes minimum size 25 cm suitably shaped and tightly clamped to the watering pipe using 25x6 mm steel bolts nut and washer and providing 2 nos, 20x3 mm GI strip from test joint to earth plate bottom level clamped at 2 locations on the plate and on the test joint bolted with steel bolts,nuts etc ,providing GI funnel welded with the watering pipe and making masonry chamber built with bricks and duly plasterd and providing cast iron cover plate etc complete
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
OD230408/2022-2023:Supply and providing 25x3mm brass nut and bolt etc. as required.
OD230409/2022-2023:Supply and fixing 63 A 415 V , 2 way neutral link mounted on DMC / SMC base in the existing meter board and giving connection etc.
OD230410/2022-2023:Supply and fixing 63 A backelite fuse base with HRC fuse link in the existing meter board and giving connections etc
OD230411/2022-2023:Supply and Installation of dust and vermin proof , wall mounting , Sintex 3 Phase meter box of size 650x350x250 mm suitable for fixing KSEB meter ,fuse units etc, hinged door connection for the front side with compartments if necessary , providing vision panel for the meter component , knock out for cable entry and exit.( GSMB?6535 )
Bidder Name
SHEFEEK K I
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_803493.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .