Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹28.9 LAccepted-AOC VILL POST BARANACHINA PS DINHATA DIST COOCH BEHAR 736135 | COOCHBEHAR | WEST BENGAL | 736135 | L-1 | Accepted-AOC Being L-1 | |
| 2 | L-2₹31.2 L+₹1.9 L (6.53%)Rejected-Finance 24B JYOTISH ROY ROAD KOLKATA 700053 | KOLKATA | WEST BENGAL | 700053 | L-2 | Rejected-Finance Being L-2 | |
| 3 | L-3₹33.5 L+₹4.2 L (14.4%)Rejected-Finance KHUDIRAMPALLY P O BANARHAT DISTT JALPAIGURI W B PIN 735202 | JALPAIGURI | WEST BENGAL | 735202 | L-3 | Rejected-Finance Being L-3 | |
| 4 | L-4₹33.9 L+₹4.6 L (15.7%)Rejected-Finance VILL DEPOPARA BINNAGURI PO BINNAGURI DIST JALPAIGURI W B PIN 735 203 | JALPAIGURI | WEST BENGAL | 735203 | L-4 | Rejected-Finance Being L-4 | |
| 5 | L-5₹34.2 L+₹4.9 L (16.8%)Rejected-Finance GOKUL APARTMENT PANJABIPARA DISTT JALPAIGURI SILIGURI 734401 WB | DARJEELING | WEST BENGAL | 734401 | L-5 | Rejected-Finance Being L-5 |
Tender Value
₹46.9 L
EMD Value
₹93,800
Closing Date
2 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (NORTH) BINNAGURI
GE North Binnaguri Post Binnaguri Dist Jalpaiguri West Bengal PIN - 735232
PROVISION OF RAIN WATER DRAINAGE (270 RM FROM RP GATE 2 TO OTM 4 NALLAH TRI JN AND COOK HOUSE 5 TO OTM 7 (130 RM) AND CERTAIN REVENUE AND MINOR WORKS UNDER AGE B/R-I OF GE (NORTH) BINNAGURI
2023_MES_615150_1
NIT No. 8701 / 28 / 2023-24 / 19 / E8
Open Tender
Civil Works
Item Rate
180 days
BINNAGURI CANTONEMNT
Class D Category a (i)
8 documents required · 8 mandatory
₹500
GE (NORTH) BINNAGURI
₹93,800
Yes
23 Nov 2023
23 Aug 2023
4 Oct 2023
23 Aug 2023
2 Oct 2023
18 Sept 2023
Amount
Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter in deep for foundation etc or for pipes walls cesspits, manholes, pier holes etc not exceeding 10 Sqm on plan and getting out in soft/ loose soil complete all as specified and as directed.
M&L for cement concrete 1:3:6 type C2 using 40mm graded stone aggregate as in foundation and mass filling complete all as specified and as directed.
M&L for brick work with fly ash bricks old size bricks in cement mortar in CM 1:4 straight or curved on plan exc 6 m mean radius complete all as specified and as directed.
M&L for PCC 1:3:6 type C1 using 20mm graded stone aggregate as in surface channels and drain including necessary form work, moulds etc complete all as specified and as directed.
M&L for PCC 1:3:6 type C1 using 20mm graded stone aggregate as in drain coping etc with slightly chamfered or rounded angles including necessary form work if any, and finishing exposed surface even and fair without using extra cement complete all as specified and as directed.
M&L for PCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in benching for drain with slightly chamfered or rounded angles including necessary form work if any, and finishing exposed surface even and fair without using extra cement complete all as specified and as directed.
Extra for forming fair finish to drain or channel 30 cm inner girth in cement concrete using extra cement including forms moulds/mitered stopped ends etc complete all as specified and as directed.
M&L for rendering 15mm thick on fair faces of brick or concrete surfaces in cement mortar 1:4 and finished even and fair without using extra cement complete all as specified and as directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and as directed.
Removing excavated material (soil) exc 50m but n.exc 100m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and as directed.
Demolition of stone slab and tiles of any description or thickness as in floors, apron etc laid dry or bedded and pointed in any mortar complete all as specified and as directed.
M&L for cement concrete type C1 1:3:6 (using 20 mm graded stone aggregate) 75mm thick as sub base complete all as specified and as directed.
M&L for 18 mm to 20 mm thick granite (of any type) work (table rubbed and polished) in steps, Jambs, pillars, window cills, cooking platforms, corner shelf, flat shelf and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite and including 15 mm thick screed bed (1:4) including rounded the exposed surfaces of granite complete all as specified and as directed.
M&L for 18-20 mm thick marble work (table rubbed and polished) in steps, Jambs, pillars, window cills, cooking platforms, corner shelf, flat shelf and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite and including 15 mm thick screed bed (1:4) including rounded the exposed surfaces of granite complete all as specified and as directed.
M&L for RCC 1:2:4 (B1) with using 20mm graded aggregates as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
M&L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs etc also splays between floors and beams etc flat rough finished surface of concrete complete all as specified and as directed.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
All as per item Ser No 17 above but 8mm dia and over TMT bars upto and including 10mm dia in stirrups, spacers and binders and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for stainless steel framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted or forged into spikes; framed guard bars and similar work of ornamental Stainless steel of grade 304 as per approved design/drawing etc complete all as specified and as directed.
Demolition of brick work built in cement mortar and removing from site complete all as specified and as directed.
M&L for brickwork with fly ash bricks straight or curved on plan exc 6 mtr mean radius built in cement mortar 1:6 by using old size bricks complete all as specified and as directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out soft/loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and as directed.
Dismantling floor, hearth or wall tilling including cement mortar being (but not backing), and rubbish throw off the premises complete all as specified and as directed.
M&L for rounding to edge of stone, Granite slab, kota stone slab one edge, such as in steps, cooking platform and other similar work complete all as specified and as directed.
M&L for cement concrete type B0 1:2:4 (using 12.5 mm graded stone aggregate) 25mm thick as sub base complete all as specified and as directed.
M&L for Vitrified Ceramic Tiles light shade 8-9 mm thick (square/ rectangular) polished, area of each tiles not exceeding 1.0 sqm, laid over 15mm thick screed bed in CM (1:6) as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles as in floor complete all as specified and as directed.
S&F rolled mild steel tubular sections (square rectangular or circular hollow sections)as in Column, roof trusses (framed), trussed, purlins, crane gantry, rails, fastening, heavy bracket framing (Beam, tee, angle, channel or flat section ,Tube etc), including distance pieces, cleats etc. confirming to Fe - 410- W including cutting, welding & necessary fittings such as nut bolt, plate etc complete all as specified and as directed.
S&F rolled mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and as directed.
S&F 2 mm thick fiber glass reinforced translucent corrugated sheet with two corrugation side lap fixed with J type screw and washers in roof wall / covering/cladding to wall complete all as specified and as directed.
S&F solid PVC Wall Lining consisting of 5mm thick single side prelam wood grain printed PVC sheet inclusive of solvent cement and fixing at site on PVC frame as specification and drawing complete all as specified and as directed.
S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified and as directed.
S&F 110 mm dia PVC SWR pipes single socketed, in any length with rubber ring joints fixed to walls or laid on floors/trends complete all as specified and as directed.
S&F in 110 mm dia PVC bends/shoe of any radius with access door complete all as specified and as directed.
S&F in 100 mm dia 1 mm thick drop ends of mild steel sheet galvanised complete all as specified and as directed.
S&F in 100 mm dia 1 mm thick stop ends of mild steel sheet galvanised complete all as specified and as directed.
S&F plain, galvanised, mild steel sheeting 0.63mm thick, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and as directed.
S&F flat iron brackets supports or stays for valley gutter or as in wind tie confirming to Fe 290 Gde E 165 complete all as specified and as directed.
M&L for Rendering 15mm thick in CM (1:6) on concrete/brick wall surfaces finished even and fair without using extra cement complete all as specified and as directed.
M&L for preparing old oil bound distemper surfaces of walls including cornices, pilasters and other wall features etyc by washing rubbing down and stopping and applying and finishing the walls with textured exterior paint of required shed two or more coats applied @3.28 ltr/10 sqm over and including priming coat of exterior primer applied @2.2kg/10 sqm complete all as specified and as directed.
M&L for preparation of new steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
S&F in repair powder coated aluminium window sliding type three track (one gauge and two glazed shutter) aluminium sections weighing not less than 0.55 Kg per mtr for shutter and aluminium sections weighing not less than 1.67 Kg per mtr for frame including necessary jointing cleats, glazing cleats, rubber packing, screws, handle, locking arrangement etc complete and 4 mm thick tinted glass and stainless steel mosquito proof gauge complete all as specified and as directed. Note: Standard size and section as shown on HQ CE Siliguri Zone Drg No CESZ/2018/TD-09 Sheet 1/8 to 8/8.
S&F in repair powder coated anodised aluminium frame (sections weighting not less than 1.40 kg/mtr) made of Square/tubular Aluminium section for door with one or more rebates jointing cleat for fixing etc and provision of aluminium door shutter (Single/Double shutter) including necessary jointing cleats glazing clips, rubber gasket aluminium anodised snap beading, screws, hold fast, Aluminium hinges 3Nos 100mm long for each shutter, floor stopper, locking arrangements handle 4 mm thick tinted glass fixed in panels complete and all as directed. Note: Standard size and section as shown on HQ CE Siliguri Zone Drg No CESZ/2018/TD-08 Sheet 1/2 to 2/2.
Taking down cement plaster on wall / Ceiling of any description including racking out joints, hacking for key and scrubbing down with water etc complete all as specified and as directed.
M&L for preparation of newly plastered or un plastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer after applying 1 mm thick cement based wall putty to wall surface complete all as specified and as directed.
S&F 2mm thick poly carbonate sheet with compact clear/bronze sheet/colour sheet fixed with screw/‘J’ type screw including all necessary fitting & fixture in roof/wall/covering cladding/railing etc complete all as specified and as directed.
INTERNAL ELECTRIFICATION Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed.
M&L for point wiring complete with 1.5 Sqmm single core PVC insulated unsheathed FR-LS cable 1100 volts grade (ISI marked) with multistranded copper conductor with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 1.5 Sqmm PVC insulated multistranded unsheated copper conductor cable FR-LS (ISI marked) with proper colour coding as earth continuity conductor connected to common earth dolly, modular sheet steel sunken terminal box of appropriate size suitable for modular switch/ fittings concealed in walls, with modular back plate, top cover fixed flush to wall for housing switches, socket outlets, fan regulators etc duly earthed including cutting chases of existing wall for conduits and sinking for boxes and making good to the disturbed surface of wall/floor and matching with existing specifications. Connections of cable with MCB's or bus bar shall be done through proper size copper/brass thimbles complete all as specified and as directed for the following :-
One light point controlled by one way switch 5/6 amps complete all as specified and as directed.
One ceiling fan/Exhaust fan point controlled by one way switch 5/6 amps complete all as specified and as directed.
One socket out let 5/6 amps point on the same board complete all as specified and as directed.
One socket out let 5/6 amps point on the independent board complete all as specified and as directed.
S&F modular switch of 5 amps, 230 volts one way complete all as specified and as directed.
S&F modular socket 2 in 1, 5 Pin, 5/6 amps, white ivory finish flash type complete all as specified and as directed.
S&F modular switch socket combination 2 and 3 Pin, 5/6 amps, multipurpose flush non shutter, non inter locking type white ivory finish with complete all as specified and as directed.
S&F ceiling rose, bakelite, surface type, 220/240 volts, three terminals complete all as specified and as directed.
S&F in modular fan electronic regulator 120/280 volts AC 50 Hzs rotary step white/ivory finish of 2 module complete all as specified and as directed.
S&F lamp holder, insulated body, with back plate suitable for batten/angle fittings complete all as specified and as directed.
S&F LED white glass Lamp 1x9 Watt 230V Base-22 complete all as specified and as directed.
S&F IP 20, Class I, LED light 1X18 W (or nearest next higher wattage) (4feet), 5700K, wall/ surface mounted, integrated type with aluminium housing and decorative and caps with integrated high efficiency electronic driver and surge suppressor of 2KV or more, luminaire efficiency > 95 lumens/watt, power factor > 0.90, operating range - 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/ square blocks, screws etc complete with all accessories internally prewired and connecting up complete all as specified and as directed.
S&F Energy saving new generation environmental friendly long life versatile pressure die cast aluminium IP 66 security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 25 watts with pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting and GI pipe bracket made out of GI pipe medium grade 32 mm dia 1.5 mtr long bend to required shape complete all as specified and as directed.
M&L for concealed sub-main wiring alongwith earth wire of size of 2 x 6.0 sq. mm + 1 x 6.0 Sqmm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) of size not less than 25 mm with all fittings and accessories ISI marked including cutting chases for conduits & making good to walls, floors etc complete, including taking down old unserviceable aluminium sub main wiring complete all as specified and as directed. Note: Two runs of 6 sqmm conductor for main and one run of 6 sqmm conductor as earth wire with proper colour coding including one run of PVC conduit shall be measured as one unit length. Connections of cables wit MCBs or bus bar shall be done through appropriate size brass/ copper thimbles
S&F MCB distribution boards (DBs) with sheet metal enclosure, double door, IP 43 protection, 240 Volts, 8 way, single pole and neutral, with 200 Amps rated copper bus bar (as per OEM), neutral link, earth link earthing studs, suitable for fixing MCBs, without MCBs fixed flush to wall/other surface complete all as specified and as directed.
S&F for MCB, Single pole & neutral, 32 to 63 amps, 240 volts, ‘C’ curve, 10KA all complete with and including taking down old unserviceable one complete all as specified and as directed.
S&F for MCB, Single pole, 5 to 32 amps, 240 volts, ‘C’ curve, 10 KA all complete with and including taking down old unserviceable one complete all as specified and as directed.
Material and labour for earthing complete with galvanized steel plate electrodes of size600x600x6mm thick buried directly in ground with earth pit not less than 2.25 meter deep below normal ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised iron strip25 x 4 mm earth lead by means of nuts, bolts, check nuts and washers including 15 mm bore galvanized iron pipe, light grade for protection of earth lead upto the length of 7.5 meter towards test terminal and 20 mm bore galvanized iron pipe, light grade for watering, and providing of charcoal and common salt in alternate layers, including necessary earth work in any type of soil and including PCC pit in PCC 1:2:4 with provision of wire mesh and funnel, complete all as shown in electrical plate No 3 of SSR Part-I including testing on complete all as specified and as directed.
S&F for ceiling fans with all accessories 230 V,1200 mm sweep BEE 5 star rated, conforming to IS 374:1979 complete with pre wired with 3 core cable complete all as specified and as directed.
S&F LED decorative fancy type lighting suitable for outdoor/indoor 10 to 15 W, ceiling hanging type (Jhumar type) to be fixed under the shed and making all necessary electric connection complete all as specified and as directed.
S&F LED strip lighting 24 W out put, 6500 K, long life along the surface of the open shed and making suitable electric connection complete all as specified and as directed.
M/S SINHA ENTERPRISE
S. G. CONSTRUCTION
M/S D S CONSTRUCTION CO
ANIL ENGINEERING CO
M/S SARKAR BROTHERS
SHRI PRADEEP PARIK
N K Construction
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .