Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.6 LAccepted-AOC 2 A NARENDRA APPARTMENT CENTRAL JAIL ROAD SUBHASH BRIDGE AHMEDABAD 380027 | AHMEDABAD | AHMEDABAD | GUJARAT | 380027 | ₹43.6 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹47.0 LRejected-Finance 05 MR PRASHANT DESHMUKH PLOT NO 05 SHUBHALAKSHMI APARTMENT ADHYAPAK LAYOUT HINGNA T POINT NAGPUR 440036 MH NAGPUR NAGPUR MAHARASHTRA 440036 UDYAM MH 20 0031710 | NAGPUR | MAHARASHTRA | 440036 | ₹47.0 L | L2 | Rejected-Finance Being not L1 |
| 3 | L3₹51.5 LRejected-Finance | ₹51.5 L | L3 | Rejected-Finance Being not L1 |
| 4 | L4₹54.0 LRejected-Finance | ₹54.0 L | L4 | Rejected-Finance Being not L1 |
| Sl No | Description | Qty | Unit | Shree Krushna Supply Corporation L1 | BRITE INDUSTRIES L4 | GLOBAL POWER SYSTEMS L2 | Shree Saaram Engineers L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | Supply installation, testing and commissioning of silent Diesel Engine driven generating set rating 58.50KVA/47KW, 415 volts, 3 phase 4 wire, engine as per IS:10001/ 10002 Comprising liquid cooled Disesl Engine ,CPCB IV NORMS+EMISSION COMPLIANCE) std: BHP @ 1500RPM & 58.5 KVA Alternator rated at 3 phase,47.04 KW at 415 Volts, 50HZ; 0.8 P.F. @1500 RPM both mounted, and aligned on a common iron base frame complete with MS Fuel Tank integrated AMFcontrol Panel having meter, relay and switch gear and sound proof canopy, AVM Pads fitted on base frame, 1 No. 12 Volts DC Battery, Leads, DG Set should be capable of operating in temperature range (-) 1 Deg to (+) 50 Deg Celcius with, 1st Fill of Lube Oil. complete, Engine shall be equipped with all standard fittings as per manufactuer, all as following specification and including PCC foundation as Per OEM recommanded/Drg | 1 | Each Job | 8,30,000 ₹8.3 L | 13,75,000 ₹13.8 L | 8,80,000 ₹8.8 L | 10,01,000 ₹10.0 L |
| 1.01(B) Alternator :- Alternator's rating 58.50 KVA, 3 Phase, 50 cycle, 415 Volts, 4 wire supply at NTP 0.80 logging power factor at an altitude of 36 Mtr above MSL, running @ 1500 RPM self excited, self regulated, mounted on strong steel fabricated steel frame suitable for mounting on a permanent foundation to be coupled with above engine. (C) Control Panel :- Alternator control panel inbuilt with internal copper wiring for 58.50 KVA alternator, 415 Volts, 3 Phase, 4 wire, 50 cycle, fabricated out of 2.0mm thick MS sheet painted externally and internally with two coats of synthetic enamel paint over one coat of primer all as per manufacturer's design including provision of following accessories :- (i) Suitable scaled flush mounted AC voltmeter with selector switch 0-500 Volts - 01 Set. (ii) Suitable scaled flush mounted ammeter with selector switch & CT’s of suitable range - 01 Set. (iii) Frequency meter - 01 No. (iv) KW and KWH meter. (v) Power factor meter - 01 No (vi) MCCB 4 Pole for suitable capacity - 01 No. (for incoming) as recommended by manufacturer. (D) cooling : Liquid cooled(EG compleat 50:50). (E)Silencer :- Crtical Grade Silencer intergrated with DOC, suitably optimised to meet stringent emission standards laid down by MoEF/CPCB. (F) The foundation of DG set shall be provided as per manufacturer's drawing / instructions and quoted rate shall deemed to be included for this provision and nothing extra shall be admmisible on this account. (G) Contractor shall submit e-way bill, Purchase Voucher, Test certificate/ Test report etc alongwith payment. (J) Stack height for DG Sets should be high as per CPCB norms | |||||||
| 1.02(H) Controls/Protection : (i) Low LOP fault indication (ii) Indication for Water Temparature, (iii) High Colant Temparature fault Indication, (iv) Failure to start fault indication (v) Battery Volage monitoring, (vi) Low Battery Indication, (vii) Fuel level Indication, (viii) Engine RPM meter, (ix) Engine run hours meter, (x) Voltage for all three Phases, (xi) Amper meter for measuring current in all three phase. (xii) Frequency meter indication, (xiii) Protection for Over/Under Voltage (xiv) Protection for Over/Under Voltage (xv) Electronic tamper proof KWH meter 3 phase, 4 wire system with suitable ratio CTs. (xvi) Oveload protection (xvii)Suitable capacity of Battery charger shall be provided in the control panel to charge the batteries when mains supply in availbale.(xvii) Safeties against low Lube oil Pressure, high coolant Temperature, over load under & over voltage, under & over frequency Auto Shut Down, Visual & Audio Alarm against fault. When the Gen set is running the battery will be charged from the charging alternator.(e) DG power Control Panel shall be outdoor type sheet steel type cubicle type control panel ,floor standing, dust and vermin proof under normal conditions complete with all internal wiring & will house the following:- (i) AC voltmeter (ii) AC ammeter (iii) vibrating reed Frequency meter (iv) Indicating Lamps for SET ON & LOAD ON (v) MCCB for short circuit & Overload Protection (vi) Aluminium Bus bars of adequate rating (vii) Provision for bottom entry & Exit of power cabling (viii)set of current transformer (ix) set of control fuses. | |||||||
| 1.03(J) Other fitting (i) Battery Charger -Battery charger having electric circuit consisting of triodes, rectifiers, capacitor and resistance etc. The battery charger should be able to charge the battery at all the time whenever electric supply is given to the battery. "Note (i) Battery capacity as per OEM recommendation". Note:- Height of foundation should be 1.2 Mtr from GL and the rate of foundation deemed to be included in quoted rate. (ii) Fuel tank made up of MS Sheet of suitable capacity as per manufacturer’s instructions capable to store fuel for 12 hours running of DG set fixed as per manufacturer`s design and return fuel pipe with all pipes connecting upto fuel pump including oil level indicating gauge, drain plug for cleaning and air vent plug etc. (iii) Accousite enclosure with natural air circulation without loss of any power for ventilation fan. The enclosure shall be modular in construction with hinge bolted structure to provide easy dismantling and shall be made out of high quality CRCA sheet steel of 1.6mm thick with sufficient accessories for maint work, openable and locable door with air light rubber gasket, interior lighting arrangement. | |||||||
| 1.04NOTE:- (a) DHPP for testing purpose shall be supplied by the contractor without any extra cost to Department (b) The contractor shall arrange for artificial load (water load/Electrical load) for testing for final testing of DG Set at Site and the cost is deemed to be including in above offer. (c) All expences for Testing of DG Set be included. (d) One set of latest Spare part catalogue with price, exploded view of parts and user's manual are deemed to be included in the offer. (e) All civil work including foundation for DG set as per manufacturer's drawing/specification, foundation for AMF panel. (f) The rate quoted is deemed to be included for initial filling of radiator colant and lubricating oil upto level. | |||||||
| 1.05Testing :- (i) All routine test certificates from the manufacturer in respect of the diesel engine, alternator and the control panel will be made available by the contractor. (ii) The Generating set shall be run for a period of 12 hours, of which at least 6 hours shall be at the rated load and for a period of one hour at 10% over load in above 12 hours running. (iii) All instruments, equipments, materials including DHPP and Engine oil and labour required for testing will be made available by contractor at his own cost and unit rate in Sch 'A' will be deemed to be included for testing to the entire satisfaction of Engr-in-Charge :- (a) Insulation resistance test on the alternator and control panel. (b) High voltage test as per BS-2613 clause 33 on the alternator when still hot. (c) Efficiency test at rated load and over load.(d) All test as described above under testing clause shall be carried out in presence of officer nominated by accepting officer. | |||||||
| 2.00 | M&L in replacement Earthing complete with galvanised steel earth plate electrode 600x600x6mm buried directly in ground not less than 2.25 Mtr deep below normal ground level with top edge of earth plate not less than 1.5mtr below normal ground level connected to the Galvanised iron strip 32x6mm size by means of bolts ,nuts, check nuts and washers of galvanised iron and 25x4mm GI strip Procter by provision of GI light grade pipe 40 mm bore incl provision of concrete pit in PCC1:2:4 type B-i , using 20 mm graded stone aggregates with 40 mm thick cover of RCC (1:2:4) reinforced with XPM weight not less than 4 Kg /Sqm and 6mm dia bar handle ,excavation and earth work in any type of soil ,charcoal dust and salt light grade GI watering pipe 20 mm bore with funnel and wire mashand medium grade GI protection pipe 15mm bore 5 Mtr long and GI strip up to main earthing of pole complete all as shown in electrical plate No 3 of MES Sch 2009 Part-I all as specified and directed. Note-: (i) The unit rate shall include for GI water pipe, protection pipe wire mesh, funnel, excavation, RCC pit cover, PCC, test point, GI strip 32 X 6 mm from top of earth plate upto 7.5 m.
(ii) PCC pit shall be provided at least 1.5m away from the earth pit and extra cost of additional length of water pipes and fixing junction, Elbows etc. shall be deemed to be included in the quoted rate.
(iii) RCC pit cover shall be precast of RCC 1:2:4, type B-1, 80 mm thick reinforced with XPM weighing not less than 4kg/Sqm in lieu of cast iron cover.
(iv) On testing after completion of earthing if the desired earth resistance is not obtained earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction of Engineer-in-charge.. | 8 | Each Job | 9,000 ₹72,000 | 8,500 ₹68,000 | 5,800 ₹46,400 | 7,000 ₹56,000 |
| 3.00 | Supply and lay in replacement cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded Aluminium conductor of size 70 sq mm 3.5 core. laid in trench/ duct / along pole/wall/ road crossing etc including making connection complete all as directed.
Note : The cost of thimbles/lugs and cable gland and LT insulation tape for insulation etc is incl in quoted rate and no extra payment will be made for it. | 25 | RM | 460 ₹11,500 | 832 ₹20,800 | 666 ₹16,650 | 539 ₹13,475 |
| 4.00 | Excavation in trenches in any type of soil not exceeding1.5 meter wide and not exceeding 1.5 metre in depth and getting out in soft/loose soil.
Note: (i) During the excavation damage of Road, Electric cable,Signal cable and Sewage line should be repaired by the contractor without any extra coast and surface should be matched as existing surface. | 14.05 | Cum | 280 ₹3,934 | 350 ₹4,917.50 | 300 ₹4,215 | 200 ₹2,810 |
| 5.00 | Removing excavated materials (soil) not exceeding 50metre and depositing where directed at a level not exceeding 1.5 meter above starting point | 5.9 | Cum | 200 ₹1,180 | 110 ₹649 | 80 ₹472 | 40 ₹236 |
Updated dates
Tender Value
₹47.5 L
EMD Value
₹94,900
Closing Date
26 Feb 2026, 6:00 pmClosed
Harikesh Meena EE
Opp Akashwani, Makarpura road PO-ONGC Baroda-390009
As per BOQ
2026_MES_750575_1
8930
Open Tender
Civil Works
180 days
GE ARMY BARODA
As per tender documents
9 documents required · 9 mandatory
₹500
GE ARMY BARODA
₹94,900
Yes
30 Mar 2026
30 Jan 2026
27 Feb 2026
30 Jan 2026
26 Feb 2026
14 Feb 2026
30 Jan 2026 - 6 Feb 2026
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.16 MB
Tenderpages8930.pdf
Tender Documents • 0.43 MB
BOQ_840644.xls
BOQ • 21.60 MB
Download all tender documents and submit your bid