Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance 23609 A INDERJEET SINGH BATH MANSA ROAD NEAR I T I CHOWK BATHINDA PUNJAB 151001 | BATHINDA | PUNJAB | 151001 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance 36 RANJEET NAGAR SHAHBAD MARKANDA NH 1 KURUKSHETRA HARYANA 136135 | KURUKSHETRA | HARYANA | 136135 | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹1 L
Closing Date
6 Jul 2020, 10:30 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer
GE (P) (AF) Ambala
Provn of soil investigation for demolation and reconstruction of Qty 04 Blast Pens at Greenfield Area at AF Stn Amnbala
2020_MES_353205_1
3004/A/EP/04/E3
Open Tender
Miscellaneous Works
Works
GE (P) (AF) Ambala
Please refer tender documents
4 documents required · 4 mandatory
₹0
Exempted
7 Jul 2020
16 Jun 2020
7 Jul 2020
16 Jun 2020
6 Jul 2020
20 Jun 2020
16 Jun 2020 - 20 Jun 2020
60 days
Amount
Job Work for Provn of soil investigation for demolation and reconstruction of (Qty-04) Blast Pens at Greenfield Area at AF Stn Amnbala. The scope of work comprises as under (a) Construction of 150mm bore diameter bores 0 to 10 meter according to IS 1892-1988 and IS 1892-1979 - 08 Nos (b) Conduction standard penetration test (S.P.T) as per IS 21311988. The testing shall be made at every change in strata or at 7 intervals of not more than 1.5 mtr whichever is less. The test may be made at least intervals if specified of considered necessary as per 3.31 of IS - 2131-1988. (c) Collection of undisturbed soil samples at an interval of 1.35 mtr or change of strata. (d) Conduction of laboratory tests on disturbed/undisturbed soil samples as per project requirement after completion of boring, as given below :- (i) Sieve analysis (ii) Plasticity index (iii) Specific Gravity (iv) Water content (v) Particle size analysis (vi) Bulk and dry density (vii) Atterberg limit (viii) Harmful salt or organic matter if any (ix) Direct shear test (in case of sandy soil) (x) Unconfined un-drained test (in case of clayey soil) (xi) Consolidation test (for saturated soil) (xii) C Value (xiii) Differential free swell test in case of expansive soil. (xiv) Unconfined compressive strength of rock (in case of rocky starta) (xv) Determination of tensile/shear strength of rock (in case of rocky strata) The firm shall submit the soil investigation completely covering the following :- (a) Bore log chart showing depth of soil strata (b) Ground water table (c) Probable maximum and different settlement (d) Safe bearing capacity based on shear and settlement (e) Recommendation for type and depth of foundation Note :- (a) The location of bldg/bores shall be given by GE (b) The soil report shall be in 3 parts i.e Tender I, II & III combined.
Determination of 'K' Value of subgrade at different location as per latest edition of relevant IS Code including submission of test report.
Soil profile to be carried out for entire 3057.00 Sqm area land and soil horizon for 04 No bore hole upto depth 0 to 10m. (i) Visual inspection of area alongwith geological history and inspection of pits/trenches should be carried out and a site plan to be submit showing diffferent soil strata, soil layer and type of soil. (ii) Bore hole diagram showing arrangement of different layers of the soil by collecting samples at the depth of every 30 cm to establish the soil profile by conducting grain size analysis. (iii) Testing of samples to determine the physical properties of the various soil materials with respect to in place density and subgrade support. (iv) Boring log : A graphic log of soil conditions can be of great value in assessing subgrade conditions. It is recommended that the graphic log be developed, which summarizes the results of the soil explorations. The graphic log should include :- (a) Location (b) Date performed (c) Type of exploration (d) Surface elevation (e) Depth of materials (f) Sample identification numbers (g) Classification (h) Water table (j) Standard penetration test (S.P.T). Soil investigation to be carried out strictly as per the guidance circulated vide E-in-C's Branch (E2 Wks) letter No 95610/SEMT/E2 Plg (Pav) dated 24 Jan 2014 under supervision of Engr-in-Charge as detailed by GE Concerned.
GEO MEDIA ENGINEERING and CONSULTANCY SERVICES PRIVATE LIMITED
National Soil Testing and Research Laboratories
VARDAN ENVIROLAB
stage.html
html • 0.02 MB
finance_394388.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .