Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹79.7 LAccepted-AOC | ₹79.7 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹80.1 L+₹39,545 (0.50%)Rejected-Finance | ₹80.1 L+₹39,545 (0.50%) | L2 | Rejected-Finance Being L2 |
| 3 | L3₹90.7 L+₹11.0 L (13.8%)Rejected-Finance PHAYANG GOMPA COMPLEX AGLING ROAD SKALZANGLING LEH LADAKH J K 194101 | LEH | LEH | LADAKH | 194101 | ₹90.7 L+₹11.0 L (13.8%) | L3 | Rejected-Finance Being L3 |
| 4 | Rejected-Technical | - | - | Rejected-Technical Disqualified as per required documents as per tender docuements not submitted by bidder |
Tender Value
₹84.1 L
EMD Value
₹1.5 L
Closing Date
6 Jun 2020, 3:00 pmClosed
CHIEF ENGINEER
HQ CE PROJECT VIJAYAK PIN 931721 C O 56 APO
PROVIDING AND INSTALLATION OF CENTRAL HEATING SYSTEM AT HQ 16 BRTF INCLUDING ALLIED UNITS AT LEH UNDER 81 RCC 16 BRTF OF PROJECT VIJAYAK IN LADAKH UT
2020_BRO_555782_1
CE (P) VIJAYAK/01/2020-21
Open Tender
Miscellaneous Services
Works
180 days
HQ 16 BRTF
As per tender documents
16 documents required · 16 mandatory
₹0
₹1.5 L
Yes
HQ CE P VJK PIN 931721 C O 56 APO
8 Aug 2020
20 Apr 2020
8 Jun 2020
21 Apr 2020
6 Jun 2020
27 Apr 2020
22 Apr 2020 - 23 Apr 2020
25 Apr 2020
Amount
CENTRAL HEATING SYSTEM AT HQ 16 BRTF INCLUDING ALLIED UNITS AT LEH
Supply, Installation, Testing & Commissioning of oil fired glycol based Hot Water Generator using Kerosene/HSD oil complete with combustion chamber fire tubes and equipment automatic mono block burner assembly tubes, control panel with sequence controller, photo cell for flame failure, HT transfer electrodes, blower assembly, electric panel, mounting frame, pressure gauges at inlet and outlet suitable for operation on 50 Hz, Single phase 220 Volts A C supply, Hot water inlet tep 85 ºC,Hot water outlet temp 75 ºC. Capacity 3,00,000 Kcl/Hr at MSL. Approved make of Alarko/Thermax/Demrad.
Specification as per schedule at srl No. 1 with Capacity: 2,00,000 Kcal/Hr at MSL. Approved make of Alarko/Thermax/Demrad.
Specification as per schedule at srl No. 1 with Capacity: 1,50,000 Kcal/Hr at MSL Approved make of Alarko/Thermax/Demrad.
Supply, Installation, Testing & Commissioning of mono block centrifugal pump driven by suitable capacity electric motor and mechanical seal bearing temperature upto 90 ºC for ethylene glycol of 28 Mtr head size 80 x 65 mm complete with accessories including cement concrete foundation and all as specified and directed of 13 lps flow rate 7.5HP. (one working one stand by) 9 lps flow rate 7.5 HP (one working one stand by). Approved make of Kirloskar/Beacon.
Supply , Installation, Testing and Commissioning of mono block Centrifugal Pump with Bronze impeller, driven by suitable capacity electric motor for glycol fluid make up and mixing complete with accessories including cement concrete foundation suitable for a flow rate of 5 LPS and 18 mtr head ) 0.5 HP. Approved make of Kirloskar/Crompton Greaves
Supply and Installation of MS flue gas chimney 200 mm dia made out of 3 mm thick MS sheet, minimum 1.2 m above the highest point of the plant room and including connection from boiler to main chimney fabricated from 3 mm MS sheet. The item shall be complete with the mounting/ fixing arrangement. The generators shall be connected to a independent chimney. The portion of the chimney in side the building shall be insulated with fiber glass insulation wool of 24kg/cum. The item shall be complete with mounting/fixing arrangement
Supply & Installation of overhead expansion tank of MS 3 mm thick tank complete covered with 13 mm closed cell electrometric insulation complete with removable lid, in/out /drain/ overflow system mounting arrangement and complete connection. Expansion tank shall be cladded with 0.50mm Almunium.Expansion Tank size 500 Ltr
Supply, Installation, Testing and Commissioning of Kerosene/HSD oil Day service Tank rectangular MS construction with capacity of 990 Liters insulated with 13MM nitrile and cladded with 0.50mm Almunium complete with inlet, outlet, drain, level indicator. Tank will be made out of 3mm MS sheet and will be provided with supports made out of minimum 50mm NB class ‘B’ pipe to keep tank base at minimum ( 800 mm) above finished floor level. The Tank shall be fitted with 3 KW Heater at outlet.
Ball Valves of sizes 25 mm
Non return Valves 25 mm
Y-Oil Strainer 25mm
GI Ball Valves of sizes 15 mm
Supplying and laying, connecting, fixing and testing of M S ERW ‘C’ class piping complete with fittings, duly insulated with closed cell elastomeric insulation 30 to 40 Kg/m3 density covered with shrink wrap polythene sheet for the following sizes of Hot Glycol fluid pipes (The pipes exposed to atmosphere and plant room shall be covered with heat shrink aluminum foil. 80 mm dia pipe with 19 mm thick nitrile insulation.
Specification as per schedule at S/No. 13 above, 40 mm dia pipe with 19 mm thick nitrile insulation.
Supply Installation Testing and Commissioning of PP-R pipes in `C` class Grade PN-20 complete with all fittings including sockets, elbows, reducers etc. Of sizes 63 mm dia pipe with 13 mm thick nitrile insulation. Approved make SFMC/KPT.
Specification as per schedule at Srl No. 15 above, 50 mm dia pipe with 13 mm thick nitrile insulation
Specification as per schedule at S/No. 15 above, 40 mm dia pipe with 13 mm thick nitrile insulation
Specification as per schedule at S/No. 15 above, 32 mm dia pipe with 13 mm thick nitrile insulation
Specification as per schedule at S/No. 15 above, 25 mm dia pipe with 13 mm thick nitrile insulation
Butter fly Valves 80 mm. Approved make Cim/Advance/Zoloto.
Butter fly valves 40mm. Approved make Cim/Advance/Zoloto.
Dual plate Non Return Valves 65 mm dia. Approved make Cim/Advance/Zoloto.
Y Srainer 65mm dia. Approved make Cim/Advance/Zoloto.
Inlet/outlet outlet imported Radiator valves size 15mm. Approved make Alarko/Demrad.
Pressure gauges with cocks and syphon
Automatic air purgers valves
Thermometer 0-90°c
PPR Ball valves 63mm
PPR Ball valves 50mm
PPR Ball valves 40mm
PPR Ball valves 20mm
Supply, Instalation, Testing and Commissioning of decorative wall mounted imported radiator units complete with grill, wall mounting brackets inlet out let manifold, sizes 33mmx600mmx2000mm (tripple panel). Approved make Alarko Carrier/Maktek/Delongi.
Specification as per schedule Srl No. 32 above, Size 33mx600mmx1600mm (tripple panel)
Specification as per schedule at Srl No. 32 above, Size 33mx600mmx1300mm (tripple panel)
Specification as per schedule at Srl No. 32 above, Size 33mx600mmx1000mm (tripple panel)
Supply, Installation, Testing and Commissioning of decorative wall mounted Fan coil units complete with grill, wall mounting brackets made from ABS body of inlet out Ball valves capacity 6000KCAL/HR. Approved make Hitachi/Universal/Samsung.
Supply, Installation, Testing and Commissioning of decorative wall mounted Fan coil units complete with grill, wall mounting brackets made from ABS body of inlet out Ball valves capacity 4500KCAL/HR. Approved make Hitachi/Universal/Samsung.
Fabricating and installing of perforated M.S. Cable trays Including horizontal and vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with M.S. suspenders and including painting.( For cabling work in plant room.) of size 100 widthX50 mm depth.
Supplying of insulated PVC sheathed aluminum copper conductor armored cables of 1.1 KV grade confirming to IS -1554 .Size 3 x 6 Sq mm (Al). Approve makes Havells/Polycab
Specification as per schedule at Srl No. 40 above, Size 3 x 4 Sq.mm (Al).
Specification as per schedule at Srl No. 40 above, Size 4 x 1.5 Sq.mm (Cu).
Providing and Fixing 6SWG dia G.I. wire on surface of in recess for loop earthing interconnecting main panel and other electrical equipment
Providing and fixing M.V. danger notice plate of 200 mm x 150 mm, made of mild steel at least 2mm thick and vitreous enameled white on both sides and with inscription in signal red color on front side as required.
Providing “ No Smoking “ and “ Flammable” sign board as per requirement of Petroleum Rules and CCOE Nagpur).
Earthing complete with galvanized steel earth plate electrode 60cm x60 cm x6 mm thick buried in ground ( earth pit not less than 2,25 meters deep below normal ground level with top edge of the plate not less than 1.5 meters below normal ground level, connecting to the Galvanized iron earth lead 32x6 mm size by means of bolts, nits check nits and washers of galvanized iron and 32 x6 mm earth lead protection by provision of GI light grade pipe 40 mm bore including provision of concentrate pit in PCC (1:2:4) type by using B -1 using 20 mm graded stone aggregates with 40 mm thick cover of RCC 1:2:4) reinforced with XPM ( weigh not less than 4gs / sqm ) and frame of angle iron 25 mm x 25 mm x6 mm with lugs 02 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe for watering perforated at the bottom 1.75 meter long placed on top edge of earth plate common salt and charcoal filling test point made out of 40 mm x 8 mm FI with fixing arrangements, funnel, wire mesh and earth work in hard/ dense soil , returning filling in and removal of surplus soil to a distance not exceeding 59 meters, all a per electrical plate No 5 of SSR-1991 Part ! and connecting to earth test point all as specified or indicated including testing on completion. (Note:- item of earthing included cost of 7.50m long galvanized iron earth lead 32 X 6 mm size and protection pipe of 40 m bore GI light grade any variation in length shall be adjusted through deviations order).
Providing and addition of Glycol suitable upto a temperature of -40°C. Approved make Deronex/Servo.
Supply and Installation of Servo stabilizer 3 phase oil cooled 12.50 kw with high and low cut off 150-460 volts. Approved make A.E./Blue Bird/Metfab.
M/S THERMOTECH ENGINEERS
Betong Construction Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .