Loading…
Loading…
Tender Value
₹13.8 L
EMD Value
₹34,475
Closing Date
15 Sept 2026, 3:30 pmClosed
Assistant Executive Engineer
Assistant Executive Engineer,KWA, PH Subdivision Parappanangadi
Supply, erection and commissioning of 40 HP Centrifugal pump set to 4.0MLD WTP at Chelari
2026_KWA_866828_1
06/2026-27/AEE/KWA/PGI
Open Tender
Electrical Works
Item Rate
120 days
CHELARI
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,760
₹34,475
15 Sept 2026
29 Aug 2026
16 Sept 2026
1 Sept 2026
15 Sept 2026
1 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1working charges | |||||
| 1.001 | OD304525/2025-2026:Supply, erection ,testing and commissioning of KWA pre-qualified reputed make Centrifugal pump sets
with Bronze/SS impeller, SS shaft and CI pump casing with suitable type base plate with coupling,
coupling guard foundation bolts & nuts etc. complete suitable for coupling the pump and motor above the
base plate etc. complete including providing suitable concrete foundation including cost of cement sand
and metal etc. completeThe duty condition is as follows."Discharge per pump: 16.00 LPS
Total Head : 130 mtrImpeller : Bronze Shaft : SS/Carben
steelSpeed : 1470 rpm".
MotorSupply, erection,testing and commissioning of KWA
prequalified reputed make horizontal solid shaft foot mounted TEFC squirrel cage induction motor
suitable for the above pump working 3 phase 50 Hz AC supply, working voltage 415 V/3300V (select the
suitable). The motor shall confirm to EEFI/IS 325 including providing suitable concrete foundation
including cost of cement sand and metal etc. complete. For 3300volts motors, digital motor protection
relay shall be included in starter as per present IE rules. Flexible coupling shall be used for coupling of
pumps and motors."". StarterSupply, erection, testing and commissioning of suitable rating
(Fully Automatic starter with air break contact for less than 100 HP and for above 100 HP FCMA starters
to be used.) starter suitable for the above motor with over voltage and under voltage protection, single
phase preventer, over load relay with motor protection relay with main contactor and bypass contactor as
per IE rules and code of practice etc. complete.""4. Panel board (suitable for operating two
pump sets but one pump set at a time) Supply, erection, testing and commissioning of cubical type
floor mounted MS fabricated dust and vermin proof common control panel board consisting of 1No.
suitable capacity MCCBs and fitted with 3 Nos. of indictor lamps, 1No. volt meter with selector switch,
1No. Ammeter with selector switch etc. Complete and provided with a common earth bus for the entire
panel and inter connect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on
acommon base frame on suitable foundation. . Cabling wRorkSupIply, layinCg, testing anEd
commissioning of suitable size XLPEcables for the above pump set from panel board to starter and
from starter to motor considering energyconservation."" Earthing Supply of all
materials and providing suitable earthing by usingsuitable size pipe/ plate earthing GI/copper strip
buried in ground and giving double earthing to motor, starter, panel board etc. as per IE
standards."". CapacitorSupply, erection, testing and commissioning of heavy duty APP
capacitor for the motor to get a power factor above 0.95. The capacitor shall confirm to IS
2834."". ValvesSupply of suitable size best quality heavy duty ISI marked CI double flanged
sluice valve and Non return valve with suitable pressure rating. Fitting of valves shall include prper RCC
support. Fitting of valves shall include proper RCC support . Fitting of valves shall include proper RCC
support especially for Non return valves. In case of positive suction pump set sluice valve should in
suction as well as delivery sides for easy repair works."". Suction and delivery pipe
connectionsSupply and fitting of suitable size best quality GI/MS pipe for a total length of 10m.
suitable for the above pump set and suitable size foot valve and connecting the suction pipe and valve
with suitable flanges, nut and bolts IR sheet etc. complete and connecting the delivery side of the pump
with valves and suitable specials to connect with the pumping main | - | set | - | - |
| 1.002 | 100.98.433:Supply of CI Non Return Valve, Conforming to IS 5312 Part I - 1984, PN 1.0, Size 250mm. | - | no | - | - |
| 1.003 | 100.98.482:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Hand Wheel PN 1.6, Size 100mm. | - | no | - | - |
| 1.004 | 100.98.481:Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Hand Wheel PN 1.6, Size 80mm. | - | no | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
KWAGeneralConditionsforeTenderingV5.pdf
PDF • 0.69 MB
Tendernotice_1.pdf
PDF • 0.05 MB
BOQ_1467391.xls
BOQ • 0.30 MB
bidocument.pdf
Tender Documents • 1.64 MB
Prelimiagrmnt.pdf
Tender Documents • 0.24 MB
correextn.pdf
PDF • 0.13 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .