POWER
19 conditions · 3 needing a document upload
Only those firms which in their individual capacity, satisfy Standard Financial Criteria(s) need to quote for this tender. :The tenderer must have minimum average annual contractual turnover of V / N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-15, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet. The tenderers shall submit Certificates to this effect which may be an attested Certificate from the concerned department / client and/or Audited Balance Sheet duly certified by the Chartered Accountant etc.
The tenderer should have a valid Electrical Contractor License from the concerned statutory authority. The above said Electrical Contractor License is to be submitted along with the offer otherwise the offer shall be summarily rejected.
a. Work shall be carried out by contractor, having valid Electrical Contractor License for carrying out installation work under direct supervision of persons holding valid certificates of competency issued by State Government.
b. Tenderer shall have a valid Electrical Contractor'sLicense issued in name of firm by any StateGovernment and shall furnish all particulars of theElectrical license held by him along with the tenderdocuments.
c.Successful tenderer shall furnish names andparticulars of certificate of competency ofsupervisor and workmen to be engaged for carryingout this work.
d. By a Gazette notification, Govt. of India hasappointed Chief Electrical Engineer, N. Rly to be theElectrical Inspector and has directed that he shallexercise powers and perform functions of anElectrical Inspector under the Indian Electricity Act2003 and Indian Electricity Rules 1956
As a proof of Technical Eligibility, the Tenderer(s) have to submit details (Technical Eligibility) as per Annexure-13 Tender Document, indicating that Contractor have completed any of the following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works costing not less than the amount equal to 40% of advertised value of the tender, or One similar work costing not less than the amount equal to 60% of advertised value of the tender. Format of completion certificate to be produced is provided as annexure-18 of tender docuemnts. Work experience certificate from private individual shall not be considered. However, in addition to work experience certificate issued by any Govt. Organization, work experience certificate issue by Public listed company having average annual turnover of Rs. 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated /registered at least 5 years prior to the date of opening of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.
Defination of Similar Work :- Wiring/Rewiring in buildings with associated electrical works. OR Lighting arrangement in buildings, circulating area, yard, street etc. with associated electrical works. OR Wiring/Rewiring, Lighting arrangement in buildings with associated electrical works.
30 conditions · 6 needing a document upload
GSTIN number: Bidder shall submit attested or self attested copy of GSTIN certificate.
Following documents shall be submitted by the tenderer: (A)SOLE PROPRIETOR SHIP FIRM: (i)All other documents in terms of clause 1.1.12 of tender document . (B)HUF: (i) A copy of notarized affidavit on Stamp Paper declaring that he who is submitting the tender on behalf of HUF is in the position of 'Karta' of Hindu Undivided Family (HUF) and he has the authority, power and consent given by other members to act on behalf of HUF. (ii)All other documents in terms of clause 1.1.12 of tender document. (C)PARTNERSHIP FIRM:(i)A notarised copy of the Partnership Deed or a copy of the Partnership deed registered with the Registrar. (ii)A notarised or registered copy of Power of Attorney in favour of the individual to tender for the work, sign the agreement etc. and create liability against the firm.(iii)An undertaking by all partners of the partnership firm that they are not blacklisted or debarred by Railways or any other Ministry / Department of the Govt. of India from participation in tenders / contracts as on the date of submission of bids, either in their individual capacity or in any firm/LLP in which they were / are partners/members. Any Concealment / wrong information in regard to above shall make the bid ineligible or the contract shall be determined under Clause 62 of the Standard General Conditions of Contract.(iv)All other documents in terms of clause 1.1.12 of tender document . (D)JOINT VENTURE (JV): APPLICABLE ONLY FOR WORKS COSTING MORE THAN Rs.10.00 Cr. Not applicable for this tender. (E)Company registered under Companies Act- 2013:(i)The copies of MOA (Memorandum of Association) / AOA (Articles of Association) of the company.(ii)A copy of Certificate of Incorporation.(iii)A copy of Authorization / Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company.(iv)All other documents in terms of clause 1.1.12 of tender document. (F)LLP (Limited Liability Partnership) Firm under LLP Act-2008: (i)A copy of LLP Agreement.(ii)A copy of Certificate of Incorporation.(iii)A copy of Power of Attorney / Authorization issued by the LLP in favour of the individual to sign the tender on behalf of the LLP and create liability against the LLP.(iv)An undertaking by all partners of the LLP that they are not blacklisted or debarred by Railways or any other Ministry / Department of the Govt. of India from participation in tenders / contracts as on the date of submission of bids, either in their individual capacity or in any firm/LLP or JV in which they were / are partners/members. Concealment / wrong information in regard to above shall make the contract liable for determination under Clause 62 of the Standard General Conditions of Contract. (G)Registered Society & Registered Trust: The tenderer shall submit: (i)A copy of the Certificate of Registration.(ii)A copy of Memorandum of Association of Society/Trust Deed.(iii)A copy of Power of Attorney in favour of the individual to sign the tender documents and create liability against the Society/Trust.(iv)A copy of Rules & Regulations of the Society.(v)All other documents in terms of clause 1.1.12 of tender document .
The tenderer shall submit a copy of certificate (Annexure 19(A)) in case of other than Company/Proprietary firm by each member of a Partnership Firm / Joint Venture (JV) / Hindu Undivided Family (HUF / Limited Liability Partnership (LLP) etc, as the case may be. Non submission of above certificate(s) by the bidder shall result in summarily rejection of his/their bid. It shall be mandatory incumbent upon the tenderer to identify, state and submit the supporting documents duly self attested/digitally signed by which they/he is qualifying the Qualifying Criteria mentioned in the Tender Document. Note:- As per railway board letter No. 2022/CE-I/CT/GCC Correspondence Dated: 14.05.2024 "On IREPS Module, a facility has already been created for online submission of Annexure-V. Therefore, the provision of downloading of Annexure-V of GCC & uploading of physically signed Annexure-V by the tenderer had been discontinued on IREPS".
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Payment of Bid-security in respect of E- tendering will be deposited either in cash through e payment gateway or submitted as Bank Guarantee bond from a scheduled commercial bank of India or as mentioned in tender documents. The Bank Guarantee bond shall be as per Annexure-VIA of GCC Works 2022(Annexure-21 of tender document) and shall be valid for a period of 90 days beyond the bid validity period and any offer without the same will be treated as invalid. Details of bank account no. and technical details have been provided for in the software (IREPS) to which prospective registered tenderers will have access at the time of tendering.
In case, submission of Bid Security in the form of Bank Guarantee, following shall be ensured: (i) A scanned copy of the Bank Guarantee shall be uploaded on e-Procurement Portal (IREPS) while applying to the tender. (ii) The original Bank Guarantee should be delivered in person to the official nominated as indicated in the tender document before closing date for submission of bids (i.e. excluding the last date of submission of bids). (iii) Non submission of scanned copy of Bank Guarantee with the bid on e-tendering portal (IREPS) and/or non submission of original Bank Guarantee within the specified period shall lead to summary rejection of bid. (iv) The Tender Security shall remain valid for a period of 90 days beyond the validity period for the Tender. (v) The details of the BG, physically submitted should match with the details available in the scanned copy and the data entered during bid submission time, failing which the bid will be rejected. (vi) The Bank Guarantee shall be placed in an envelope, which shall be sealed. The envelope shall clearly bear the identification "Bid for the ***** Project" and shall clearly indicate the name and address of the Bidder. In addition, the Bid Due Date should be indicated on the right hand top corner of the envelope. (vii) The envelope shall be addressed to the officer and address as mentioned in the tender document. (viii)If the envelope is not sealed and marked as instructed above, the Authority assumes no responsibility for the misplacement or premature opening of the contents of the Bid submitted and consequent losses, if any, suffered by the Bidder. (ix) BG/EMD shall be made in the favor of Sr Divisional Finance Manager/FZR.
1. Only firm recognized by department of industrial policy and promotion (DIPP) as "Startups" shall be exempted from payment 4.1.1 of Bid Security as per GCC 2022. 2. All other firms except described above shall be required to submit the Bid Security as per terms and conditions of tender.
PAN CERTIFICATE : PAN The tenderer shall submit the photocopy of Permanent Account Number (PAN) issued by Income Tax authority attested by Gazetted officer / self attested.
The tenderer shall study the Northern Railway General Conditions of Contract Regulations for Tenders & Contracts - 2022 or latest along with tender documents before submission of the tender.
Applicable charges/recoveries/Advance etc. (Deployment of Technical supervisors per attached Annexure XIII) is applicable.
There is an option of payment to contractor through a letter of credit (LC) arrangement (Authority Railway Board's letter no. 2018/CE-I/CT/9 dated 04.06.2018)as given in clause 1.3.14 of tender document.
GCC works 2022(or latest if any) should be the integral part of this tender.
The instructions issued under ACS 1 to ACS 12 and any latest circular/letter of RailwayBoard of GCC Works 2022 shall also prevail.
Electrical work in c/w Augmentation and Upgradation of model running room Ludhiana.
251-Elect-T-10-2026-27~NR
251-Elect-T-10-2026-27
Open
Works - General
6 Months
Firozpur, Punjab
₹0
₹1.2 L
13 Oct 2026
13 Oct 2026
21 Oct 2026
81 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 59,33,803.25 | ||
| — | 410.00 | — | — | ||
| Supply, fixing, testing, and commissioning of modular type switch 6/10 Amps as per tech. specification IS/IE rules and site requirement. | — | — | — | 62,607 | |
| — | 60.00 | — | — | ||
| Supply, fixing, testing, and commissioning of modular type switch 16 Amps as per tech. specification IS/IE rules and site requirement. | — | — | — | 10,920 | |
| — | 60.00 | — | — | ||
| Supply, fixing, testing, and commissioning of modular type 6 pin socket 6/15 Amps as per tech. specification IS/IE rules and site requirement. | — | — | — | 15,007.8 | |
| — | 100.00 | — | — | ||
| Supply, fixing, testing, and commissioning of modular type multi socket 6 Amps 5 pin as per tech. specification IS/IE rules and site requirement. | — | — | — | 13,793 | |
| — | 10100.00 | — | — | ||
| Supplying, laying, testing and commissioning of FRLS 1.0 sq mm PVC insulated multistranded copper conductor s/core cable 1100 Volt conforming to IS-694 (latest version), make Finolex, Havells, Polycab, KEI or similar in the recessed PVC conduit pipe 25 mm dia as required at site. | — | — | — | 1,22,513 | |
| — | 20000.00 | — | — | ||
| Wiring for light points with supply and laying of FRLS PVC insulated multistranded copper conductor cable 1100 Volt 1.5 Sq.mm multi stranded confirming to IS-694 latest in the existing PVC pipe. | — | — | — | 2,92,400 | |
| — | 15000.00 | — | — | ||
| Supply, laying, fixing, testing and commissioning of 2.5sq mm FRLS, PVC insulated multistranded copper conductor single core cable 1100 Volts confirming to IS-694(latest version), make Finolex, Havells, Polycab, KEI or equivalent in the existing PVC conduit for wiring of point wiring/circuit wiring/sub main/main as per Tech Spec-I attached, IS & IE rules. | — | — | — | 3,23,400 | |
| — | 8000.00 | — | — | ||
| Supply, laying, fixing, testing and commissioning of 4 sq mm FRLS, PVC insulated multistranded copper conductor single core cable 1100 Volts confirming to IS-694(latest version), make Finolex, Havells, Polycab, KEI or equivalent in the existing PVC conduit for wiring of point wiring/circuit wiring/sub main/main as per Tech Spec-I attached, IS & IE rules. | — | — | — | 2,55,520 | |
| — | 72.00 | — | — | ||
| Supply, fixing, testing and commissioning of LED tube light system wattage 2x18 Watt to 2x20 Watt complete with all mounting arrangement & accessories & flexible copper wire for connection from ceiling rose as per ISS/IR rules & site requirement as per CEE/N.Rly. Specification No.CEE/NR/121-Elect/PS/2018 (Rev '3') Dated 28.06.2018. | — | — | — | 72,454.32 | |
| — | 40.00 | — | — | ||
| Supply, fixing,testing and commissioning of LED BED LIGHT 1 WATT WITH COOL WHITE INBUILT DRIVER as per CEE/NR Specification. No.CEE/NR/121- Elect/PS/2018 (Rev '3') Dated 28.06.2018 | — | — | — | 54,000 | |
| — | 20.00 | — | — | ||
| Supply, erection,testing and commissioning of 5 w night lamp fitting complete with all fixing arrangements. | — | — | — | 14,000 | |
| — | 40.00 | — | — | ||
| Supply, installation, testing & commissioning of LED based modular type FOOT LIGHT along with 4 module box as per tech. specn. (LED light shall be conforming to CEE/NR specification no. CEE/NR/121-Elect/PS/2018(REV-3), dt. 28.06.2018 & PCEE/NR/121-Elect/PS/2019 (REV.-'4'), dt:04.11.2019 (Attached) or latest.) and site requirement. | — | — | — | 20,446.8 | |
| — | 36.00 | — | — | ||
| Supply, fixing, installation, testing and commissioning of energy efficient 230V,50 Hz AC ceiling fan size of 1200 mm sweep having wattage of 28 W, range of voltage operation at various speed-120 to 260 V AC with 5 step speed control electronic regulator, copper winding complete as per IS : 374-1979 or latest IE rule & site requirement. Make Bajaj, Usha, Havells, Crompton, Orient or equivalent. | — | — | — | 1,01,294.64 | |
| — | 380.00 | — | — | ||
| Supply, fixing,testing and commissioning of 3-pin ceiling rose 5 Amp capacity on existing MS/PVC conduit junction boxes/casing caping Anchor, Cona, Kinjal, SSK or equivalent as per IS, IE rules and site requirement. | — | — | — | 5,244 | |
| — | 3.00 | — | — | ||
| Supply, erection, testing and commissioning of the following Double door wall mounted Pre-fabricated L.T. Distribution Boards of approved make, as per explanatory note & comprising; (i) Incoming MCCB 4Pole 125 A 35 KA B/C - 1 No. (ii). Outgoing MCB 6 to 32 A. SP 10 KA B/C (7 Nos. On each Phase) - 21 Nos. | — | — | — | 48,778.32 | |
| — | 6.00 | — | — | ||
| Supply, erection, testing and commissioning of the following Double door wall mounted Pre-fabricated L.T. Distribution Boards of approved make, as per explanatory note & comprising; (i) Incoming MCCB 4Pole 63 A 35 KA B/C - 1 No. (ii). Outgoing MCB 6 to 32 A. SP 10 KA B/C (4 Nos. On each Phase) - 12 Nos. | — | — | — | 83,298.78 | |
| — | 4.00 | — | — | ||
| Supply, Installation,Testing & Commissioning of single phase RCBO of 32 Amps capacity,30mA sensitivity with Metal enclosure. | — | — | — | 10,023.72 | |
| — | 2000.00 | — | — | ||
| Transportation, Laying, underground/road/Railway track, recessing in platform /wall along with Rly. Track/in laid RCC/GI pipe as required 1.1 KV grade LT XLPE insulated armoured, aluminium conductor cable including making chase & plastering after laying of cable/digging of cable trench, sand cushioning, protective covering with second class bricks, provision of cable route marker as per Tech. Specification including end terminations with Aluminium Clamping socket/lugs, testing and commissioning of Above 25 sq.mm | — | — | — | 1,26,900 | |
| — | 20.00 | — | — | ||
| Earthing arrangement by providing earth electrode of GI pipe 50 mm dia (B class) 4.5 meter long with flange including 6 SWG GI earth wire from earth pipe to connecting point on switch board to distribution board/pole etc. as per site requirement including masonry enclosure as per Tech specification at annexure 'A' relevant ISS & IE rules and site requirements. A suitable CI/MS/RCC cover as approved by Rly . Representative, cover with locking arrangement shall be provided. | — | — | — | 46,600 | |
| — | 50.00 | — | — | ||
| Supply, laying and connection with GI Strip GI 25x5 mm (galvanized) conforming to relevant IS and as per IS 3043/1987(or Latest Version) 300mm deep in ground/recessing in flooras required. | — | — | — | 3,251.5 | |
| — | 2.00 | — | — | ||
| Supply and providing of Maintenance Free Earthing with primary MS conductor 40 mm dia 3000 mm long and secondary MS Electrode 80 mm dia 3000 mm long including digging pit of size 5ft.x5ft.x10ft. and using earth enhancement chemical compound minimum 75 kg. Per pit suitable for 40 KA current capacity and as per RDSO specification No. RDSO/PE/SPEC/PS/0109(REV- 0)-2008 and as per explanatory note. | — | — | — | 30,814.06 | |
| — | 3.00 | — | — | ||
| Supply, fixing, testing and commissioning of modular type variable refrigerant flow (VRF) air conditioning system suitable for both heating and cooling with Inverter Scroll Compressor suitable for 415 ±10% volt for outdoor unit including fully charged with refrigerant R410A to outdoor unit and all running refrigerant pipe. The outdoor shall be operational till 52 Deg. Ambient duly tested in lab. It shall include anti vibration isolator pad for outdoors unit. The unit shall be complete in all respect as per site requirement. The unit shall have auto phase corrector so that unit can work in case of phase reversal and accumulator should be present in outdoor units to prevent liquid backflow in compressor. For better energy efficiency and power saving the COP of ODU should be minimum 4.3 at AHRI conditions. OUTDOOR UNITS(i) 24 HP | — | — | — | 12,34,741.5 | |
| — | 18.00 | — | — | ||
| "Wall mounted (Highwall type) unit without drain pump": All indoor units as specified shall have; in general, noise levels less than 48db. For critical applications requiring noise levels below these limits,indoor units should be designed accordingly to meet noise level requirement. i) Each unit shall have electronic control valve to control refrigerant flow rate respond to load variation of the room. ii) The address of the indoor unit shall be set automatically or through central controller in case of individual and group control. iii) The fan shall be Turbo, multi-blade type, statically &dynamically balanced to ensure low noise and vibration free operation of the system. The fan shall be direct driven type,mounted directly on motor shaft having support from housing.iv) The cooling coil shall be made out of seamless copper tubes and having continuous aluminum fins. The fins shall be spaced by collars forming an integral part. The tubes shall be staggered in the direction of air flow.The tubes shall be hydraulically/mechanically expanded for minimum thermal contact resistance with fins. Each coil shall be factory tested at 600psi minimum (or as recommended by OEM) air pressure under water. v) Indoor unit shall have cleanable type filter with mould resistant resin net fixed to an integrally moulded plastic frame. The filter shall be slide in and neatly insert able type. It shall be possible to clean the filters either with compressed air or water. vi) Each indoor high wall unit shall be with corded/ cord less remote controller as standard features. The controller shall be able to change fan speed and angle of swing flap(for high wall) individually as per requirement. vii) All indoor Units should have force shut option to connect with fire alarm adaptor, so that the unit can be integrated with other systems to stop automatically such as in case of fire. (viii)High wall indoor units with cordless remote to be supplied and confirming to specification at TechSpec-I. 1.6 TR/438CFM | — | — | — | 6,19,087.68 | |
| — | 36.00 | — | — | ||
| Supply, installation, testing and commissioning of Refnut / Y- joints. a)Indoor Refnut | — | — | — | 1,27,006.56 | |
| — | 150.00 | — | — | ||
| Supply & Installation of Inter connecting refrigerant pipe work with (19mm/13mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor &outdoor units as per specifications, all piping inside the building shall be properly supported with MS hanger. 34.9 mm O.D (Insulation19 mm) | — | — | — | 2,37,840 | |
| — | 120.00 | — | — | ||
| Supply & Installation of Interconnecting refrigerant pipe work with (19mm/13mmthick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the building shall be properly supported with MS hanger. 28.6mm O.D (Insulation19 mm) | — | — | — | 1,56,417.6 | |
| — | 150.00 | — | — | ||
| Supply & Installation of Interconnecting refrigerant pipe work with (19mm/13mmthick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the building shall be properly supported with MS hanger. 22.2 mm O.D (Insulation19 mm) | — | — | — | 1,57,963.5 | |
| — | 150.00 | — | — | ||
| Supply & Installation of Interconnecting refrigerant pipe work with (19mm/13mmthick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the building shall be properly supported with MS hanger. 19.05 mm O.D (Insulation13 mm) | — | — | — | 1,26,352.5 | |
| — | 150.00 | — | — | ||
| Supply & Installation of Interconnecting refrigerant pipe work with (19mm/13mmthick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the building shall be properly supported with MS hanger. 15.9 mm O.D (Insulation13 mm) | — | — | — | 1,05,342 | |
| — | 300.00 | — | — | ||
| Supply & Installation of Interconnecting refrigerant pipe work with (19mm/13mmthick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the building shall be properly supported with MS hanger. 12.7 mm O.D (Insulation19 mm) | — | — | — | 1,68,348 | |
| — | 100.00 | — | — | ||
| Supply & Installation of Interconnecting refrigerant pipe work with (19mm/13mmthick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the building shall be properly supported with MS hanger. 9.52 mm O.D (Insulation13 mm) | — | — | — | 47,611 | |
| — | 100.00 | — | — | ||
| Supply & Installation of Interconnecting refrigerant pipe work with (19mm/13mmthick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the building shall be properly supported with MS hanger. 6.35 mm O.D (Insulation13 mm) | — | — | — | 42,590 | |
| — | 100.00 | — | — | ||
| Supply,installation,testing and commissioning of uPVC Pipe,complete with fittings,supports, U trap arrangement, Clean Plug and accessories for AHU/IDU as per site requirement.32 mm dia (with 9 mm Nitrile) | — | — | — | 16,278 | |
| — | 250.00 | — | — | ||
| Supply & installation of control cum transmission wiring of 2 core x0.75 sqmm copper in suitable conduits for indoor and out door units . | — | — | — | 74,325 | |
| — | 30.00 | — | — | ||
| Supply of Refrigerant (R410a) charge to the out doorunit/connected pipes between outdoor unit/ AHU or as per site requirement. | — | — | — | 24,972.3 | |
| — | 2.00 | — | — | ||
| Supply,installation,testing and commissioning of MS fabricate doutdoor unit stand for placing outdoor unit of VRV system. The stand shall be manufactured from MS C channel of minimum 3-4mm thick. It shall be finished with enamel paint as per client/architect approval | — | — | — | 6,104.34 | |
| — | 1.00 | — | — | ||
| Supply, Erection, Fixing, Testing and commissing of LT panel having incoming 1x 400 Amp MCCB 35kA FP with outgoing of 3x250 Amp MCCB 35 kA FP, 3x125 Amp MCCB 35 kA FP and 1x63 Amp MCCB 35 kA FP with Amp meter, volt meter and indicator. Make of MCCB &MCB M/s Legrand, Havells, Schenider | — | — | — | 1,97,572.73 | |
| — | 10.00 | — | — | ||
| Supply, installation, testing and commissioning of 150 Watt LED based flood light fitting, operating voltage single phase 230V AC, 50Hz complete with led lamp & all mounting arrangement, accessories & flexible copper wire for connetion as per ISS/IR rules & as per CEE/NR Specification No. CEE/NR/121- Elect/PS/2018 (Rev '3') Dated 28.06.2018 & CEE/NR/121- Elect/PS /2019 (Rev.4) dated 04.11.2019 respectively or latest latest. | — | — | — | 1,32,094.6 | |
| — | 100.00 | — | — | ||
| Design, Manufacture, supply, fixing, testing and commissioning of single sided LED type signages at platforms of suitable size as CEE/NR specification No. CEE/NR/121-Elect/PS/2018 (Rev'3') Dated 28.06.2018 or latest. and as per site requirement. Note:- Static/single sided board of different sizes name is required. prior approval of message color and size to be taken from competent authority. | — | — | — | 1,45,889 | |
| — | 1.00 | — | — | ||
| Supply and installation of 20 KVA Online UPS system input Three phase 300 V - 450 V sinewave,50Hz, output Single phase 230V +/-1% sinewave 50 Hz, Minimum VAH (VAH) 32000, Without trolley but with rack, Warranty for battery 2yr min. | — | — | — | 6,00,000 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
ACS11.pdf
ATTACHMENT
GCC_April-2022_2022_CE-I_CT_GCC-2022_POLICY_27_04_22.pdf
ATTACHMENT
LEDSpecification.pdf
ATTACHMENT
LEDSpec.1.pdf
ATTACHMENT
LEDSpec2.pdf
ATTACHMENT
GCCCorrectionSlip.pdf
ATTACHMENT
ACS3.pdf
ATTACHMENT
ACS2_1.pdf
ATTACHMENT
ACS5.pdf
ATTACHMENT
ACS6.pdf
ATTACHMENT
ACS4.pdf
ATTACHMENT
RewirngSpec-I.pdf
ATTACHMENT
ACS7.pdf
ATTACHMENT
ACS8.pdf
ATTACHMENT
ACS9.pdf
ATTACHMENT
ACS10.pdf
ATTACHMENT
GCCClarificationRegarding.pdf
ATTACHMENT
ACS12_compressed.pdf
ATTACHMENT
VRFspecification.pdf
ATTACHMENT
T-10TenderDocument.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .