| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.1 LAccepted-AOC PLOT NO 626 627 GIDC BEHIND GANGOTRI DIARY PORBANDAR 360 577 | PORBANDAR | GUJARAT | 360577 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹39.7 L+₹4.6 L (13.1%)Rejected-AOC | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹40.4 L+₹5.3 L (15.2%)Rejected-AOC | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹40.4 L+₹5.3 L (15.2%)Rejected-AOC | L4 | Rejected-AOC REJECTED | |
| 5 | L5₹40.5 L+₹5.4 L (15.3%)Rejected-AOC | L5 | Rejected-AOC REJECTED |
Tender Value
Refer Docs
EMD Value
₹71,000
Closing Date
27 Feb 2023, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I CG PORBANDAR
Military Engineer Services, GE I CG Porbandar, DHQ No. 1, Opp. Birla Cement Factory, Porbandar-360575
ADDN ALTN TO CG UNIT SHOPS FOR PROVN OF STAIRCASE AND STORES AT CGRA DHARAMPUR, UNDER GE I CG PORBANDAR
2023_MES_577829_1
8851
Open Tender
Civil Works
Item Rate
180 days
PORBANDAR
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
Yes
GE I CG PORBANDAR
₹71,000
Yes
13 May 2023
30 Jan 2023
28 Feb 2023
30 Jan 2023
27 Feb 2023
13 Feb 2023
Amount
SCHEDULE 'A'
Excavating in trenches n exc 1.5 m wide & n exc 1.5 m in depth and getting out in soft/disintegrated rock. complete all as specified and directed.
Excavating over area n exc 1.5 m deep and getting out in soft/disintegrated rock complete all as specified and directed.
Surface Excavation n exc 30 cm deep and averaging 15 cm deep and getting out in hard/dense soil complete all as specified and directed.
M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundation and mass concrete complete all as specified and directed.
M&L Reinforced cement concrete 1:1.5:3 Type A1 (20 mm graded aggregate) in foundation, footing, foundation beams, plinth beams, base of columns complete all as specified and as directed.
M&L Reinforced cement concrete 1:1.5:3 Type A1 (20 mm graded aggregate) Columns, pillars, piers, posts and struts . Complete all as specified and as directed.
M&L Reinforced cement concrete 1:1.5:3 Type A1 (20 mm graded aggregate) in beams, cantilevers, bressummers, lintels over 1.5 m span complete all as specified and as directed.
M&L for RCC 1:1.5:3 Type A1 (using 20mm aggregate) for chajjas, complete all as specified and as directed
M&L Reinforced cement concrete 1:1.5:3 Type A1 (20 mm graded aggregate) in slab supported on walls, complete all as specified and as directed.
M&L for precast cement concrete 1:2:4 , type B1 ( using 20 mm graded aggregate) in landings, cover slabs and similar articles with plain faces set in cement mortar 1:4, complete all as specified and as directed.
M&L for Formwork to flat sides with fair finish surface of concrete foundations, footings, bases of columns, raft and raft beams sides and soffits (if any) of foundation and plinth beams and similar work; vertical or to batter
M&L for Formwork to sides of pillars,posts, struts, piers, columns and stanchions with rough finish surface
Form work to soffits of suspended slabs such as roof slabs, floors slabs, landings and similar work not exceeding 200 mm thick in flat complete all as specified and as directed.
Form work to sides and soffits of floor or roof beams, beam haunching,lintel etc complete all as specified and as directed.
Formwork to chullah hoods, chajjas, troughs and similar items including edges as in rough finished surfaces of concrete complete all as specified.
Mild steel CRS TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia or securing with clips complete all as specified and as directed.
All as per item No.16.0 above, but 6mm to 8mm dia. complete all as specified and as directed.
All as per item No. above, but 5mm dia and over upto 10mm dia as in stirrups, spacers and binders
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm as in soft/disintegrated rock complete all as specified and as directed.
Removal of excavated rocks exc. 1.5 km but n.exc 5 km and depositing where directed at level n exc. 1.5M above the starting point. all as specified.
Removal of excavated soil exc. 1.5 km but n.exc 5 km and depositing where directed at level n exc. 1.5M above the starting point. all as specified.
M & L for Porbandar stone masonry, well bonded, bedded and solidly hearted built in CM 1:6 all as specified and as directed by Engineer-in-charge.
M&L 40 mm thick (measured solid) ready made reinforced precast cement concrete type B0 (1:2:4, 12.5 mm graded stone aggregate) louvres and jallies, set in CM 1:4, including all mouldings complete all as specified and as directed by Engr-in-Charge. Note : Contractors are advised to visit the samples held in the office, before submitting tender.
M&L for rendering 15 mm thick on fair face of brick work or concrete surfaces in CM 1:4 finished even and smooth wiithout using extra cement.
M&L Granules textured homogeneous wall finishing consisting of of a two component system of Dry Granules (25 Kgs per pack) made of 92% silica Particles coated with fade resisteant pigments, 100% acrylic polymer bonding agent (5 Kgs per pack) with the applied thickness of the coating between 0.8mm -1.2mm on a cured , smooth level plaster without keying, as per the shades/combinations approved, to be applied by and approved applicator of the manufacturer, as per the directions/supervision of the Engineer-in-Charge.The above textured coating should confirm to surface spread of flame class one of BS 476 : Part 7 : 1971 and pull off strength of the coating meet JISA 6909 on smooth plastered surface.
M&L for rendering 15mm thick, cement plaster, in cement mortar (1:4) mixed with integral water proofing compound as per manufactures instruction, on roof slab surfaces finished even and smooth without using extra cement,complete all as specified and directed. Note:- Water proofing compound shall be measured and paid separately)
M&L for providing APP based membrane course roof treatment in layers with following provisions:- (i) Applying one coat of bitumen's primer polymerized primer oil based coat, evenly @ 0.3KG/Sqm as priming coat to the prepared surfaces, till the surfaces is properly impregnated and the solvent oil in the base primer shall be allowed to evaporated completely. (ii) Applying APP based pre-fabricated with non woven polyester reinforced membrane stabilized with fibre glass strands and top with grey mineral slates 3mm thick and weight not less than 3.50 Kg/Sqm by torch application method. (iii) Applying a coat of solar reflective bituminous aluminium paint @ 0.10Kg/Sqm over mineral surface.
M&L for rendering 10 mm thick on fair face of brick work or concrete surfaces in CM 1:6 finished even and smooth wiithout using extra cement.
M&L for rendering 15mm thick, cement plaster, in cement mortar (1:4) mixed with integral water proofing compound as per manufactures instruction, on fair faces of brick walls or concrete surfaces finished even and smooth without using extra cement in any height, complete all as specified and directed. Note:- Water proofing compound shall be measured and paid separately)
Supply only water proofing compound (integral) all as specified & directed.
M&L for rendering 5mm thick cement plaster in cement mortar 1:3 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement on ceiling in any height complete all as specified and directed.
M&L moorum/red bajri filling in floors or pavings, laid in layers n exc 15cm thick, spread, levelled and rammed including watering complete all as specified and as directed by Engr-in-charge
M&L for broken stone or boulders Hardcore of gauge exc 63 mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface all as specified.
M&L 75 mm thick Cement concrete 1:3:6, type C2 (using 40 mm graded stone aggregate) as in plinth protection finished even and smooth without using extra cement.
M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate 75 mm thick as in sub base
M & L for 60 mm thick M-35 Grade Machine pressed precast concrete paver block of any colour any shape and size confirming to IS 15658-2006 with grey cement and pigment complete all as specified and as directed.
M & L for 50 mm thick Sand filling under floors or in foundation including watering and consolidation complete all as specified and as directed.
M&L for cement concrete (1:2:4), type B-1, using 20mm graded mechanically crushed stone aggregate as in coping, bed block benching, kerbs, mud stop, rounded or chamferred on edges including necessary form work/moulds complete all as specified and as directed.
M&L for PCC (1:2:4) type B1 using 20 mm graded aggregate as in floor of average 25 mm thick including preparation of existing surface complete all as specified and as directed.
M&L for Non skid ceremic coloured tiles 7 to 8 mm thick ( square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over screed bed or bedding layer of mortar 15 mm thick 1:6 complete all as specified and as directed by Engineer-in-charge.
Ditto as above but in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over backing coat of mortar 10 mm thick 1:4 complete all as specified and as directed by Engineer-in-charge.
M&L 18 mm to 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over screed bed or bedding layer of 15 mm thick 1:6 etc. complete all as specified and as directed by Engr-in-Charge
S&F Stainless steel pipe of grade 304, of any dia for railling / balusters over existing parapet including base, collars, caps, head caps and anyother specials etc including necessary welding, polishing and drilling in masonary and filling with epoxy grout etc complete all as specified and directed by Engineer in charge.
S&F stainless steel of Grade 304 as in framed work as in doors or gates of angles or other section with gusset plates, rails, braces, sheet sheeting for covering etc, complete drilled for fixing of door and sheet etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings, running rails and guides and hanging, also fastening and fixing complete all as specified and directed.
S&F mild steel iron angle/ tubular section as in framing for cladding, glazing and the like fixed with angle cleats and connecting plate complete using Fe-410-W( Gde E-250) quality-A
S&F Plates (plain or chequered) , channels, square cut or notched ( ordinary and counter sunk) forming holes, without any attachment etc complete using Fe-410-W( Gde E-250) quality-A
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screw complete all as specified and as directed.
S&F Pre-painted galvalume aluminium zinc coating GI based plain sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screw complete all as specified and as directed.
Providing and fixing Aluminum Composite panels in all colours of approved brand for external / internal wall cladding at all heights and elevations including necessary aluminium composite panel consist of 3mm thermoplastic core of anti oxidant LDPE sandwitched between two skin of 0.5 mm thick alloy sheet making a total sheet thickness of 4 mm. The surface shall be finished with PDVF base coating on the top side and service coating on the reverse side shall be with a polymer paint. The system to be fixed to the brick/stone/masonry/RCC walls/framed structure with necessary clamps, bracket and anchor fasteners fixed over and including base frame fabricated with aluminium square pipe of size 25mmx25mm with 1mm thickness in 600mmx600mm size grid including stainless steel screws, nut, bolts, washers, cleats, weather silicone sealent for groove filling, backer rods etc, complete all as per Manufacturer instruction and all as specified and as directed by Engr-in-Charge. All Clamps and brackets shall be hot dip galvanised minimum 80 micron thick and confirmed to IS : 4759 - 1996. The extruded aluminium sections shall be anodised in approved colour with anodic coating minimum 20 microns. (items include cost of aluminium frame, ACP , Cramps, weather sealent, gasket, foam, fixtures, scaffolding and making louvers in front face with ACP, all machineries and any other fastening streps, nuts, bolts, rivets, washers, etc complete). The manufacturer shall also give guarantee/warranty for ACP for a period of Five years. Notes: a) The Contractor should have working experience of similar nature of work for last three years. b) The ACP should have installed by authorized company/agent. Make of ACP:- ALUPEX/ALUDECOR/ALSTRONG/TIM
S & Fixing of Writing letters or figures (Block, Roman, Hindi,Italic or Indian) of size not exc 45 cm high with stainless steel Grade 304 incl chiselling for letters on granite surfaces.
M&L for preparation of new plastered or unplastered surfaces and applying two coats of oil bound distemper on wall over a coat of alkali resistant primer over two coat of wall care putty (water proof) complete all as specified and darected.
M&L for Preparation of new plastered surfaces of ceiling and applying three coats of white wash all as specified and directed.
M&L for preparation of new plastered surfaces of wall and applying two coats of 100 % Premium acrylic emulsion paint having VOC less than 50 gm/ltrs and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm all as per the manufacturers instructions, complete all as specified and directed by Engr-in-charge.
S&F powder coated aluminium anodised three track sliding window shutter and frame including jointing clit for fixing frame/chowkhat of window as per JINDAL section code (frame 20831), shutter (20846) including glazing with 5mm thick tinted glass & Aluminium wire mesh necessary fittings, rubber packing, suitable handles, rollers for shutters etc complete all as specified and as directed.
S&F powder coated aluminium grill with suitable aluminium anodised frame F/H section manufactured by M/s DECO GRILL as per design No DG-104, 6 mm thick complete all as specified and as directed.
S & F Steel rolling shutters, with out ball bearing, as specified including top cover, an choring rod, hasp and staple and one shop coat of primer; erected in position as indi cated, complete: push pull or manual type , thickness of laths 1.25 mm complete all as specified and as directed.
M&L for Aplying two coat of anticrosive paint on steel surfaces of any description, over 10cm in width or girth,not otherwise described
Point wiring complete with 1.5 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable 650/1100 Volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit (minimum 20 mm dia external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I ISI marked with wall thickness not less than 1.8 mm including conduit accessories like bends, tees, junction boxes etc fixed concealed/ recessed in wall or ceiling etc including 1.5 sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire including modular type metal flush box with cover plate and frame of required modules for mounting of modular switches, sockets, switch sockets, fan regulators with required modules all as specified etc for the following:-
One light /fan point controlled by one, one way switch
One 3 pin 6 Amps socket outlet on same board
One 3 pin 6 Amps socket outlet on independent board .
M&L for Point wiring complete with 2.5 Sq mm single core PVC insulated but unsheathed multistrand copper conductor FRLS cabeI 650/1100 Volts grade conforming to IS-694 drawn through PVC conduit (minimum 20 mm dia (external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR Part I) ISi marked with wall thickness not less than 1.8 mm heavy duty including conduit accessories concealed pressed steel terminal boxes of size cover white/coloured including 2.5 Sq mm PVC insulated but unsheathed copper conductor FRLS cable as earth continuity wire for one 3 pin 15 or 16 Amps socket outlet on independent board, including modular type metal flush box with cover plate and frame of required module for mounting of modular switches, sockets, switch sockets with required modules all as specified.
Supply & fix modular switch 1 way, 6 Amps, 1 modular (ISI marked).complete all as specified and as directed. Make : Legrand / Anchor (Roma)/ L&T
Supply & fix modular switch 1 way, 16 Amps, 1 modular (ISI marked).complete all as specified and as directed.
Supply & fix modular socket, 6 Amps, 2/3 pin combind 2 module (ISI marked).complete all as specified and as directed. Make : Legrand / Anchor (Roma)/ L&T
Supply & fix modular socket, 6/16 Amps, 2/3 pin combind 2 module (ISI marked).complete all as specified and as directed. Make : Legrand / Anchor (Roma)/ L&T
Supply & fix modular fan regulator, 120 watt, 2 moduler (ISI marked).complete all as specified and as directed. Make : Legrand / Anchor (Roma)/ L&T
Supply & fix ceiling rose, surface bakelite, 65 x 17 mm three terminals (ISI Marked) complete all as specified and as directed. Make : Legrand / Anchor (Roma)/ L&T
S & F in of wall mounted LED Tube light fitting 1 x 20W LED (6500K), 4 feet, Sleek and seamless profiled extruded aluminium batten with an efficient diffuser to illuminate work, including making connections with 2 core flexible copper wire 0.50 Sq mm from ceiling rose after fixing fitting complete all as specified and directed. Make Wipro - CAT PT No- LL20-281-XXX-65AL1** or equivalent to Bajaj/Havells
S & F in of wall mounted LED Tube light fitting 1 x 10W LED (6500K), 2 feet, Sleek and seamless profiled extruded aluminium batten with an efficient diffuser to illuminate work, including making connections with 2 core flexible copper wire 0.50 Sq mm from ceiling rose after fixing fitting complete all as specified and directed. Make Wipro - CAT PT No- LL20-111-XXX-65NE3* or equivalent to Bajaj/Havells
Supply & fix BEE star rated Ceiling fan 1200 mm sweep and connecting up to and including provision of 23/0.0076 flexible three core PVC insulated copper conductor cable from ceiling rose to fan etc complete all as specified and as directed. make: Orient, CG, Havells, Usha
Supply and fix AC Single phase Two wire tamper proof static meter of Class 1.0, 240 V 50Hz basis current 10A. Max continuous current 600% of basis conforming to IS-13779 and relevant IEC standards with in built Low Power Radio Frequency (LPRF) communication facility in Cyantech or equivalent Mesh network with default and no demand display, billing data generation facility anti tamper fearures microprocessor and LED/LCD based circuitry Make L&T, HPL, Secure or equivalent.
S & F distribution Board cum Meter box wall mounting type of size 980 X 950 X 335mm (minimum) fabricated from polycarbonate sheet, IP 54 cimpartmentalised design, Cable gland of suitiable size prewired and comprising of following :- (a) MCCB cap 63 Amps, 4 Pole, 16 KA - 01 No.(In Coming) (b) MCB SP 40 Amp, 10 KA - 05 Nos (Out Going) (c) Terminal for distribution (d) 04 Nos of cubicals for housing single phase meter all as specified and as directed. Make Hensel/Hager/Universal
M&L for sub main wiring with two single core 4 Sqmm PVC (FRLS) insulated multistranded flexible copper conductor cable 660/1100 volts grade down in through including Concealed PVC Conduit with all accessories, PVC insulated 2.5 Sqm single core single strand copper conductor as continous earth wire in green colour connected to common earth dolly all as specified and as directed. Note : 1. Two runs of cable, one run of earth wire, one run of PVC conduit will be measured and paid one unit.
S & F in replacement of MCB DB 8 way SPN, double door, vertical type, IP - 53 with 200 Amps rated bus bar, Concealed and connecting up complete all as specified. Make : Legrand/ Havells/ ABB
Supply and fixing in replacement of MCB SPN, 240 volt, 32 Amps complete all as specified. Make : Legrand/ Havells/ ABB
Supply and fixing in replacement of MCB SP, 240 volt, 6 to 32 Amps complete all as specified. Make : Legrand/ Havells/ ABB
Supply and fix earthed metal clad socket outlet with earthed plug top 20 Amps capacity with sheet metal enclosure and one 20 Amps MCB SPN all as specified and directed. Make : Legrand/ Havells/ ABB
Supply and laying of XLPE insulated and PVC armoured heavy duty 1100 volt grade electric LT UG cable with aluminium conductor of size 10 Sqmm 4 Core laid in trenches/along the wall/pole including making good the disturbed surfaces of walls/floor etc all connections complete as required at site and as directed. Make : Polycab / Havells/ RR Kabel
Excavation in trenches not exc 1.5 m wide and not exc 1.5m in depth and getting out Soft/ Loose soil complete all as specified and directed.
Returning filling in incl spreading levelling watering and well Ramming in layers not exc 25 cm thick complete all as specified and directed.
Removing excavated material not exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified.
S & F of GI steel tubing light grade 32 mm dia for laying in ground and road crossing along the pole in coping etc for cable protection including necessary fittings, clamps for supports, etc., including making good the disturbed surfaces of walls/floor etc all as specified and directed. Make - Tata/Jindal/Surya Prakash
Supply and lay 50 /38 mm Double Walled Corrugated (DWC) Pipes having corrugation on the outer wall and plain surface on the inner wall confirming to IS14930 (Part-II) for protection of UG cables, laid in trenches/ road/ drain or fixed along wall, poles or laid under floor all as spd and as directed by Engr-In-Charge. Make : Rex / Poly/ Gemini
M&L for cutting existing road/hard standing not exc 45 x 45 cm in wide & depth getting out excavated material for laying cable/GI tube, returning filling & well rammaing watering finish suraface 10 cm from top using PCC 1:3:6; including removal of surplase soil complete all as specified and directed.
M&L for bore Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 2.5 metres length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthing lead of 4mm dia galvanised iron or steel wire all as shown in Plate No. 2 to the earthing test point all as specified and indicated including testing on completion complete all as specified and directed.
RAJESH ENTERPRISE
Leo Elevator Company
shivshakticonstruction
Nitesh Enterprise
roxy enterprise
K B N TRADERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .