Electrification of newly constructed Laboratory Complex at school of Biotechnology
2022_NITC_703855_1
Engg/EMU/AE/146/2022-23
Open Tender
Electrical Works
Item Rate
30 days
NIT Calicut
please refer tender documents
9 documents required · 9 mandatory
₹590
Director, NITC
₹32,500
Yes
20 Dec 2022
29 Jul 2022
16 Aug 2022
29 Jul 2022
12 Aug 2022
29 Jul 2022
Amount
Wiring for light point/ fan point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Supplying and fixing of 20 mm (medium class) ivory coloured rigid PVC conduit along with accessories in surface / recess including cutting the wall / floor and making good the same in case of recessed conduit as required.
Supplying and fixing of 25 mm (medium class) ivory coloured rigid PVC conduit along with accessories in surface / recess including cutting the wall / floor and making good the same in case of recessed conduit as required.
Supplying and fixing of 32 mm (medium class) ivory coloured rigid PVC conduit along with accessories in surface / recess including cutting the wall / floor and making good the same in case of recessed conduit as required.
Supplying and drawing 3 numbers 1.5 sq.mm FRLS PVC insulated copper conductor single core cable (Red, Black & Green) in the existing surface/recessed PVC conduit as required.
Supplying and drawing 3 numbers 2.5 sq.mm FRLS PVC insulated copper conductor single core cable (Red, Black & Green) in the existing surface/recessed PVC conduit as required.
Supplying and drawing 3 numbers 4 sq.mm FRLS PVC insulated copper conductor single core cable (Red, Black & Green) in the existing surface/recessed PVC conduit as required.
Wiring for circuit/ submain wiring alongwith earth wire with 4 X 10 sq. mm + 2 X 6 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required.
Wiring for circuit/ submain wiring alongwith earth wire with 4 X 16 sq. mm + 2 X 6 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required.
Supplying and fixing 5/6A modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Supplying and fixing 3 pin 5/6 A modular socket outlet on the existing modular plate & switch box including connection, but excluding modular plate etc as required.
Supplying and fixing 15/16A modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Supplying and fixing 6 pin 15/16 A modular socket outlet on the existing modular plate & switch box including connection, but excluding modular plate etc as required
Supplying and fixing of DLP Plastic trunking of size 150 x 50 mm with clip on partitions (2 compartments) 2 Nos 65 mm or nearest suitable width flexible cover, fitted on the wall with steel screws, cup washers etc. as required.
Supplying and fixing of 4 module frame and cover plate for 65 mm or nearest size cover on DLP trunking etc. as required.
Supplying and fixing of 6 module frame and cover plate for 65 mm or nearest size cover on DLP trunking etc. as required.
Supplying and fixing of end cap in the existing DLP Plastic trunking of size 150 x 50 mm as required.
Supplying and fixing of internal angles in the existing DLP Plastic trunking of size 150 x 50 mm as required .
Supplying and fixing of external angles in the existing DLP Plastic trunking of size 150 x 50 mm as required .
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing extra down rod of 10 cm length G.I. pipe,15mm dia, heavy gauge including giving connection with 0.5 sq.mm 3 core round flexible copper wire and painting the down rod etc. as required. (Note:More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supply of 28 W, Fully diffused recessed mounted 1'X4' LED luminaire with high transmitive diffuser fitting,CRCA housing, Efficacy > 125 Lum/W, CCT - 5700K, CRI >80 complete with all accessories including suitable size powder coated Aluminium frame for fixing the light fixture etc, as required. (Philips Model No. RC380B LED36S-6500 G5 L3W12 PSU OD (Full Glow) / Compatible) (The cost of GI wire for fixing the light fixture to the ceiling is to be included)
Supply of 36 W,Fully diffused recessed mounted 2'X2' LED luminaire with high transmitive diffuser, CRCA , Efficacy >=100 lum/W, CCT>=5700K, CRI>80complete with all accessories including suitable size powder coated Aluminium frame for fixing the light fixture etc, as required etc, as required. (Philips Model No. RC360B LED36S-6500 V1 L60W60 PSU OD (Full Glow) / Compatible) (The cost of GI wire for fixing the light fixture to the ceiling is to be included)
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing 6 - 32 amps rating, 240 Volts, 'C' curve miniature circuit breaker suitable for inductive load of single pole in the existing MCB DB complete with connectons, testing and commissioning etc as required.
Supplying and fixing 40 amps rating, 415 Volts, 'C' curve miniature circuit breaker suitable for inductive load of Triple pole in the existing MCB DB complete with connectons, testing and commissioning etc as required.
Supplying and fixing 40 A rating, 415 V, 'C' curve miniature circuit breaker suitable for inductive load of Triple pole and neutral in the existing MCB DB, complete with connections, testing and commissioning etc. as required.
Supplying and fixing 40 amps rating, Four pole (Three phase and neutral) 415 Volts, residual current circuit breaker (RCCB), having a sensitivity current up to 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc as required.
Supplying and fixing 63 amps rating, 415 Volts, 'C' curve miniature circuit breaker suitable for inductive load of Triple pole in the existing MCB DB complete with connectons, testing and commissioning etc as required.
Supplying and fixing 63 A rating, 415 V, 'C' curve miniature circuit breaker suitable for inductive load of Triple pole and neutral in the existing MCB DB, complete with connections, testing and commissioning etc. as required.
Supplying and fixing 63 amps rating, Four pole (Three phase and neutral) 415 Volts, residual current circuit breaker (RCCB), having a sensitivity current up to 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc as required.
Supplying and fixing 125A, 36 kA, 4 pole (three pole and neutral), 415 Volts, moulded case circuit breaker (MCCB) with thermomagnetic release and terminal spreaders in existing MCCB DB, complete with connections, testing and commissioning etc. as required.
Supplying and fixing 3 phase 4 way, double door, suface/recess mounting, vertical type, 415 V, TPN distribution board with provision for fixing MCCB as incomer and TP MCB as out going, complete with 200 A tinned copper bus bar, common neutral link, earth link, din bar for mounting MCBs, detachable gland plate, interconnections, earthing, phosphatized and powder painted, fixing using bolt and nut, giving connections etc. as required. (But without MCCB, MCB)
Supplying and fixing of 3 phase 12 way (8 + 36), Double door surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs as required . (But without MCBs and incomer)
Supplying and fixing 3 phase 8 way (8 + 24), Double door, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supply of 1.1 kV grade 3.5 C x 70 sq.mm, Aluminium conductor XLPE insulated PVC sheathed armoured power cable as required.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 70 sq.mm size clamped on wall surface with 25x3mm MS flat clamp as required.
Charges for removing the existing wiring, making good the damages of the wall / floor including painting other accessories without any damage and conveyance of the material to the godown etc, as required.
Supply and making end termination with brass compression gland and aluminium lugs for 3.5 C x 70 sq mm (38 mm) size of PVC sheathed / XLPE aluminium conductor of 1.1KV grades as required.
LAMOS TECHNOLOGY SOLUTIONS PVT LTD
Power Care Electrical
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .