Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹65.0 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹68.1 L+₹3.1 L (4.72%)Rejected-Finance III 246 MANIYATTU BUILDING KURUPPAMPADY P O RAYAMANGALAM ERNAKULAM KERALA 683545 INDIA | ERNAKULAM | KERALA | 683545 | L2 | Rejected-Finance L2 |
| Sl No | Description | Qty | Unit | candelaengineering corporation L2 | POWER TEC L1 |
|---|---|---|---|---|---|
| 1.00Street lights | |||||
| 1.00 | 90.15.3.6:Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70 mm top diameter, 130 mm bottom diameter thickness 3mm base plate dimensions of 200x200x12 mm suitable for wind speed as per IS 875 Part III double arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc. complete 7 Meters | 41 | each | 26,790 ₹10,98,390 | 21,000 ₹8,61,000 Lowest |
| 1.00 | OD372287/2024-2025:Supply installation testing commissioning of 2.5 Mts hight HD GI decorative Pole, made of mild steel/steel tube thickness minimum of not less than 3 mm. Pole shall have two sections, bottom section shall be minimum height of 1mts with dia of 114 mm. The upper section shall be not less than 1.5 mts with minimum dia of 76 mm. The pole is to be provided with a suitable surface mounting base plate and welded at the bottam of pole. Pole shall be mounted on square base plate, suitable for mounting on 4 nos foundation bolts. The base plate dimensions shall be 200x200x12 mm. The pole shaft and base plate shall be hot dip galvanised (7 stage process before the coating of epoxy primer to minimum 65 microns. Poles using pre galvanizes steel tubes or hot dipped galvinized trough double dip process are not acceptable. After galvanisation complete pole shall be treated with 2 layer of high quality epoxy primer and there after coated with polyurethane paint (marine grade paint) to minimum average DFT of 100 microns (total thickness minimum 160 micron-test report shall be submitted) The pole shall have internal junction box / control box. Designed to basic wind speed of 169 km with out any deformation or damage to the structural. (Kesss lec HD GI 2.5 Classic pole with base plate/K lite/Crompton make) | 88 | each | 18,300 ₹16,10,400 | 14,100 ₹12,40,800 Lowest |
| 1.00 | 90.15.4.2:Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) | 82 | each | 4,950 ₹4,05,900 | 4,062 ₹3,33,084 Lowest |
| 1.00 | OD372937/2024-2025:SITC of LED Decorative Classic luminaire of system wattage 30W, BIS certified with a body and frame of high pressure die cast aluminium, a frosted PMMA protector (IK06) fixed on to the optical unit, separate optical and control gear compartment accessed by opening four screws at the top of the luminaire, a vent pressure equalization unit and pre-cabled as required. The luminaire shall have ingress protection of IP66. Highly efficient temperature resistant lenses for light distribution with several optical options providing excellent photometry to optimally cater to different applications. Overall system efficiency of 110lm/W at correlated colour temperature (CCT) 3000K, colour rendering index (CRI) >70 and L70 rated lifetime of 50,000 hours. Electrical Class I, rated voltage 240Vac,Power Factor ≥ 0.95, with BIS certified potted driver having internal surge protection of 4 kV and an additional surge protection device (SPD) of 10 V. ( KESSLEC RILA 30W WW LED/equivalent) | 88 | each | 14,500 ₹12,76,000 Lowest | 15,061 ₹13,25,368 |
| 1.00 | 90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm | 1,182 | metre | 50 ₹59,100 Lowest | 80 ₹94,560 |
| 1.01 | 90.12.7.40:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp | 135 | metre | 230 ₹31,050 Lowest | 230 ₹31,050 Lowest |
| 1.01 | 90.12.7.41:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp | 10 | metre | 275 ₹2,750 | 245 ₹2,450 Lowest |
| 1.01 | 90.12.5.40:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 10 sq mm | 2,820 | metre | 200 ₹5,64,000 | 190 ₹5,35,800 Lowest |
| 1.01 | 90.12.5.41:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 16 sq mm | 75 | metre | 220 ₹16,500 Lowest | 220 ₹16,500 Lowest |
Tender Value
₹74.1 L
EMD Value
₹50,000
Closing Date
2 May 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Kannur Muncipal corporation
Kannur Municipal Corporation Beautification Project No SO 1101 25 Gandhi Circle Electrification
2025_LSGD_761916_9
E7 948/2023 dt.25-04-2025
Open Tender
Electrical Works
Item Rate
180 days
Kannur
Please refer Tender documents.
8 documents required · 8 mandatory
₹2,760
Yes
₹50,000
Yes
1 Sept 2025
26 Apr 2025
3 May 2025
26 Apr 2025
2 May 2025
26 Apr 2025
Amount
Street lights
90.15.3.6:Supply installation testing and commissioning of Octogaonal Pole made of hot dip galvanised GI sheet 70 mm top diameter, 130 mm bottom diameter thickness 3mm base plate dimensions of 200x200x12 mm suitable for wind speed as per IS 875 Part III double arm bracket 0.5mt including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc. complete 7 Meters
OD372287/2024-2025:Supply installation testing commissioning of 2.5 Mts hight HD GI decorative Pole, made of mild steel/steel tube thickness minimum of not less than 3 mm. Pole shall have two sections, bottom section shall be minimum height of 1mts with dia of 114 mm. The upper section shall be not less than 1.5 mts with minimum dia of 76 mm. The pole is to be provided with a suitable surface mounting base plate and welded at the bottam of pole. Pole shall be mounted on square base plate, suitable for mounting on 4 nos foundation bolts. The base plate dimensions shall be 200x200x12 mm. The pole shaft and base plate shall be hot dip galvanised (7 stage process before the coating of epoxy primer to minimum 65 microns. Poles using pre galvanizes steel tubes or hot dipped galvinized trough double dip process are not acceptable. After galvanisation complete pole shall be treated with 2 layer of high quality epoxy primer and there after coated with polyurethane paint (marine grade paint) to minimum average DFT of 100 microns (total thickness minimum 160 micron-test report shall be submitted) The pole shall have internal junction box / control box. Designed to basic wind speed of 169 km with out any deformation or damage to the structural. (Kesss lec HD GI 2.5 Classic pole with base plate/K lite/Crompton make)
90.15.4.2:Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
OD372937/2024-2025:SITC of LED Decorative Classic luminaire of system wattage 30W, BIS certified with a body and frame of high pressure die cast aluminium, a frosted PMMA protector (IK06) fixed on to the optical unit, separate optical and control gear compartment accessed by opening four screws at the top of the luminaire, a vent pressure equalization unit and pre-cabled as required. The luminaire shall have ingress protection of IP66. Highly efficient temperature resistant lenses for light distribution with several optical options providing excellent photometry to optimally cater to different applications. Overall system efficiency of 110lm/W at correlated colour temperature (CCT) 3000K, colour rendering index (CRI) >70 and L70 rated lifetime of 50,000 hours. Electrical Class I, rated voltage 240Vac,Power Factor ≥ 0.95, with BIS certified potted driver having internal surge protection of 4 kV and an additional surge protection device (SPD) of 10 V. ( KESSLEC RILA 30W WW LED/equivalent)
90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
90.12.7.40:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
90.12.7.41:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp
90.12.5.40:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 10 sq mm
90.12.5.41:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 16 sq mm
90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
90.12.10.3:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation63/50 mm or nearest size
9.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
9.1.33:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
OD396174/2024-2025:Supply and providing test joint for the earthing system using 2 x 25 x 3 mm GI strip including cutting and bending to shape, drilling necessary holes and fixed to the watering pipe etc as required
OD396175/2024-2025:Supply and providing earth lead from the test joint to the earth electrode using 25 x 3 mm GI strips including cutting, drilling necessary holes (in case of strip) and fixing firmly with plate test joint etc as required
90.16.1.9:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.64 mm GI conductor (12 SWG)
90.16.1.11:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.06 mm GI conductor (8 SWG)
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
90.16.5.4:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG)
1.17.1:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.1 x 1.5 sq. mm
1.17.11:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
OD360895/2024-2025:Supply and fixing Analog timer of Havells(Cat No.DHTED30016) or similar make of Theben,OBO, L&T etc.
OD360897/2024-2025:supply conveyance installation of dust and vermin proof, wall mounting, thermoplastic meter box of following size suitable for fixing KSEB meter, fuse units, CT etc, hinged door construction for the front side with compartments if necessary, providing vision panel for the meter compartment, knock out for cable entry and exit-.650x350x210mm
OD360893/2024-2025:Supply and providing the 25 x 3mm brass bolt & nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required
OD360899/2024-2025:Supply and providing the 12 x 3 mm brass bolt & nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required
OD360901/2024-2025:Supply and fixing the following accessories in the existing meter board and giving connections etc.32 A, 415 V, 2 way neutral link mounted on DMC/ SMC base
OD360898/2024-2025:Supply and fixing the following accessories in the existing meter board and giving connections etc.32 A fuse holder with fuse link
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
90.16.2.3:Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.32 mm dia G.I pipe ( medium class)
OD360905/2024-2025:Dismantling of Cement concrete inter locking tiles flooring including resetting the same in the position after earth work as per the direction of Engineer in charge.
14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
14.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
14.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement).
14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels
90.16.2.4:Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.40 mm dia G.I. pipe ( medium class)
OD360900/2024-2025:Supplying and fixing 32 mm dia 6 kG/cm2 PVC pipe including fixing the pipe with clamp/clip at 60 cm spacing etc. as required(For Service pipe)
OD360902/2024-2025:Fabrication,supply,conveyance and installation of Granite name board with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick,indicating the cost involved, the dates of commencement, completion, inauguration etc on stone slab
OD360908/2024-2025:Supply ,conveyance and fixing 15 amps rating dual row Electric barrier strip screw terminal block wire connector up to 12 points.
90.15.2.2:Supply installation testing and commissioning of High Mast using Octogaonal Pole made single/two sections of hot dip galvanised GI sheet 70mm top diameter, 130mm bottom diameter thickness 3mm base plate dimensions of 200x200x16 mm suitable for wind speed as per IS 875 Part III with head frame assembly two point suspension system with steel wire rope 5mm dia double drum winching system w and including round arm galvanized luminary carriage suitable to install 6/8 nos luminaries in symmetrical arrangement control gear box and lighting spikes with single phase operation power tool installed inside the base compartment including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc, complete 10 Meters
90.15.4.11:Supply Conveyance, installation, testing and commissioning of 200W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
90.14.2.1:Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.
90.14.3.2:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding suitable for 1.60/ 2.00 mm sheet
2.10.5:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
OD395206/2024-2025:Supply and providing 3 Phase 4 Pole contactors for switching light circuit.
OD395207/2024-2025:Supply and fixing class B+C Type surge protection device 3 P+N AC 4 pole 400/440 V AC Surge Protection Devices systems with potential free contact, thermal disconnector & provisions for inbuilt common remote indication for defective arrestors of OBO/Citel/L&T/Dhen make or similar make including earth connection.
OD395437/2024-2025:Dismantling the existing GI/MS 6-9 meter Pole single/double arm bracket including connector foundation bolt 4 nos fixed in existing RCC foundation and junction box etc, and conveyance to the section store with out further damages including disconnecting the existing light fittings.
civil items
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
candelaengineering corporation (BID ID -2205937)
Bidder Name
candelaengineering corporation
POWER TEC
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1240149.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .