Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.8 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹49.5 L+₹1.1 L (2.30%)Rejected-Finance | L2 | Rejected-Finance BecomeL2 |
Tender Value
Refer Docs
EMD Value
₹99,000
Closing Date
15 Apr 2023, 6:00 pmClosed
GE South Tezpur
GE South Tezpur, Mission Charlia
REPAIR TO FLOOR, PLASTERING, JOINERY, PLUMBING, FENCING AND OTHER MISC B/R WORKS FOR POWER HOUSE AT ZONE-1 (B) AND ZONE-5 AND REPAIR/MAINTENANCE OF STREET/SECURITY LIGHTS AND GARDEN LIGHTS AT ZONE -2 (A AND B), 4 ZONE 5, ZONE 1 (HQ 4 CORPS) AND REPA
2023_MES_585273_1
8734
Open Tender
Civil Works
Item Rate
210 days
GE South Tezpur
As per NIT
4 documents required · 4 mandatory
₹500
Yes
GE South Tezpur
₹99,000
Yes
5 Jul 2023
10 Mar 2023
17 Apr 2023
10 Mar 2023
15 Apr 2023
25 Mar 2023
11 Mar 2023 - 23 Mar 2023
Amount
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering and removing surplus soil to a distance not exc 50m and making good surfaces as in soft/loose soil, all as specified and directed.
Surface excavation n.exe 30 CM deep and avg 15 CM deep and getting out in soft/loose soil, complete all as specified and directed.
Excavating in trenches n. exc. 1.5 m. wide and n. exc. 1.5 m. in depth; for foundation and getting out in soft/loose soil, complete all as specified and directed.
Returning filling in , including spreading,levelling,watering & well ramming in layers not exc 25 cm, complete all as specified and directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and directed.
M&L for Hardcore of guage n exe. 63 mm deposited spread and leveled in layers n exe 15 CM thick watered and rammed to a true surface (broken stone or boulders), complete all as specified and directed.
M&L for Sand filling under floors or in foundations or in trenches including watering and consolidation complete all as specified and directed.
Taking down chowkats or frames not exc 1.5sqm each with shutters( without taking off shutters from the frame ) including dismantling of PCC bed blocks for hold fasts, complete all as specified and directed.
Taking down chowkats or frames exc 1.5sqm and not exc 4.0 sqm each with shutters ( without taking off shutters from the frame ) including dismantling of PCC bed blocks for hold fasts, complete all as specified and directed.
Taking down of shutters of any description exc 1.00 Sqm and n.exc 2.00 sqm each, complete all as specified and directed.
Taking down of shutters of any description n.exc 1.00 Sqm and each, complete all as specified and directed.
Refixing of shutters of any description exc 1.00 Sqm and n.exc 2.00 sqm each in same opening including of taking down, easing, adjusting and renewal/refixing of builders hardware as required including renewal of unserviceable screws and welding etc, complete all as specified and directed.
Refixing of shutters of any description n. exc 1.00 Sqm each in same opening including of taking down, easing, adjusting and refixing/renewal of builders hardware as required including renewal of unserviceable screws, etc, complete all as specified and directed.
S&F 2nd class hard wood plain, solid, straight in chowkats and framed rebated on the solid rounded or chamfered put together with glue pinned at joints including making rebate for fixing second shutter as per site requirement, complete all as specified and directed.
S&F 30 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides, complete all as specified and directed.
Supply and fix 30mm thick second class hard wood glazed and skeleton, open rebated and prepared to receive glass/ wire cloth, gauze exc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitered beads for securing glass etc. The sizes of members of shutters as per IS-1003 (Part-2), kiln seasonable and chemically pressure treated and fitted to chowkhats complete all as specified and directed. (Note : Glass / wire cloth will be measured and paid separately), complete all as specified and directed.
S&F factory made solid PVC door frame of size 50mm x 47 mm made out of 5mm plain coloured PVC sheet reinforced with MS square tube as specified & directed.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tube for top & bottom rails MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC stiles and plain colour PVC sheets for top rail, lock rail bottom rail on either side & as gap insert for top rail & bottom rail paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stile & rails with suitable PVC sheet beading & jointed together with solvent cement all as specified and shown on drawing, complete all as specified and directed.
S&F factory made solid PVC Moulded Door Shutter, With 20mm multi chamber hollow PVC profile (stiles), with 2, 4, or 6 raised panel design with 5mm thick Moulded Prelam PVC Sheet on the front face & 5mm Prelam PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing on page no. 161 of SSR Part -II complete all as specified and directed.
S&F 100mm size type B-21 Butt hinges extruded aluminum alloy with galvanised MS sheet hinges pin anodized, complete all as specified and directed.
S&F 75mm size type C-21 Butt hinges extruded aluminum alloy with galvanised MS sheet hinges pin anodized, complete all as specified and directed.
S&F extruded aluminum alloy handles fabricated type, anodized, 150mm long, complete all as specified and directed.
S&F extruded aluminum alloy handles fabricated type, anodized, 100mm long, complete all as specified and directed.
S&F Aluminum anodized sliding door bolts of size 300mm long, with hasp & staple ( bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminum alloy, complete all as specified and directed.
S&F in repair Aluminum anodized sliding door bolts of size 300mm long, with hasp & staple ( bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminum alloy, complete all as specified and directed.
S&F Aluminum anodized barrel tower bolts of extruded section 200 mm long and fixed with screws, complete all as specified and directed.
S&F Aluminum anodized barrel tower bolts of extruded section 150 mm long and fixed with screws, complete all as specified and directed.
S&F in repair MS helical door spring 150 mm size incl roller and roller plate fixed to wooden or steel frames with welding etc complete all as specified and directed.
S&F steel windows with side hung shutter including projecting type hinges with steel handle and steel peg stay, complete with glazing bars, detailed or welded all as specified and directed.
S&F steel window with side hung shutter, including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded complete all as specified.
Supply and fix, steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and directed
S&F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, complete all as specified and directed.
S&F in repairs Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, complete all as specified and directed.
Hacking out old broken glass any thickness, size, quality or description from wooden / metal frame works, glazed with putty or fixed with beads, complete all as specified and directed.
S&F 4 mm thick frosted/ pin headed glass in ventilator shutters, complete all as specified and directed.
S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty in square not exc 0.50 sqm in each pane complete all as specified and directed.
Dismantling timber scantling 40 Sqcm and over in section in any position in framed work, complete all as specified and directed.
M&L 2nd class HW in scantling fixed clean swan in framed work, complete all as specified and directed.
Dismantling timber scantling under 40 Sqcm in section in fillests, rails , posts, rafters and purlins etc in any position in framed work or unframed work, complete all as specified and directed.
M&L 2nd CL HW plain fillets square, rectangular in section clean sawn sectional area exe 13 sqcm & n.exe 25 sqcm fixed with nails including one coat of black oil, complete all as specified and directed.
Supply & Fix in repairs floor door stopper of brass body and tongues with hard drawn steel spring, overall length cover plate 150mm complete all as specified and directed
Dismantling Wall and ceiling boards (fiber, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets all directed.
S&F false ceiling with powder coated exposed G.I. grid suspension system Everest E-Grid T-2430 or equivalent load carrying capacity with mid span deflection not exceeding 1/360 span with hanger spacing of 1200 mm c/c) consisting of Main Runner (3600 mm long, 0.25 mm thick, 38mm height) Cross Tee (1200mm/600mm long, 0.25 mm thick, 27 mm height) and Wall Angle (3000 mm long, 0.4 mm thick, 22 mm height). The Wall Angle shall be fixed on PVC Dash Fasteners on the perimeter of the wall by steel screws with distance 300 mm c/c. The Main Runners to be placed @ 1200mm, The Cross Tee 1200mm will be inserted in the pre-cut slots of Main Runner at a regular interval of 600 mm to form a modular grid of 1200mm x 600mm. Additional Cross Tees of 600 mm shall be placed perpendicular to the Cross Tee 1200 mm long to finally form a grid of 600mm x 600mm. Grid of module size 600mm x 600mm shall be supported by 6 mm dia G.I. wire from purlins/soffit. 4 mm thick High Pressure Steam Cured Everest Non Asbestos Fiber Cement Designer Ceiling Board or equivalent quality having Density>1200 Kg/m3, size 595mm x 595mm, confirming IS 14862 & Type B Category III of ISO 8336, tested as per AS-1530 part 3 & BS-476 Part 4,5,6,7&8, should be placed in the Grid module to form a False Ceiling, complete all as specified and directed.
Dismantling asbestos cement corrugated semi corrugated etc sheets in roof covering, complete all as specified and directed.
S&F 0.5mm thick pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet of any colour ,tensile strength of 550Mpa as in roof covering ,cladding to wall ,ridge, gutter etc fixed with self tapping screws, complete all as specified and directed.
All as per item No.45 above but plain sheet for ridge ,gutter etc fixed with self tapping screws as specified.
Dismantling Structural steel work including door, gates, etc and similar works, complete all as specified and directed.
S&F of joist, channel, angle, flat iron or Tee sections, fixed independently with connecting plates, etc confirming to Fe 410-W (Gde 250 quality A) complete all as specified and directed.
Supply & Fix framed works such as grills grating etc with ends of bars shouldered and for riveted in forged into spikes, framed guard bars, railing and similar work confirming to Fe-410-0 or Fe 310-0 complete all as specified and directed
S&F Framed work such as in gate, rollers, cleats, base plates , plain or chequred and rail etc, with and similar work conforming to Fe 290. Gde -E-165 for framed and hung as gates including hold fast pintle hinges stops hand made sliding bolts and ornamental and intricate design etc, all as specified and directed.
S&F Collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding(but not backing) complete and removing rubbish off the premises complete all as specified and directed.
M&L Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM 1:6, complete all as specified and directed.
S&F Coloured Glazed ceramic tiles 450 x 300 mm x 6 to 7mm thick, in skirting /dado etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm rendering in Cement mortar 1:4, complete all as specified and directed.
M&L for Chequred cement concrete tiles of size 300 x 300 x20 to 25 mm thick with grey cement and pigment, set and jointed and pointed in neat cement slurry in floors laid over & including 15 mm thick screed bed in cement mortar 1:6 Complete all as specified and directed.
M&L Machine pressed precast concrete interlocking paver block (Glazed finish) with Grey cement and pigment any shape any size confirming to IS 15658-2006 of 60 mm thickness, M-30 Grade laid over sand cushioning 58 cm average filling, complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15cm thick above or below ground level all as specified and directed.
M&L Cement concrete 1:4:8 (Type D2) in foundations, filling and mass concrete all as specified and directed.
Material and labour for providing Plain Cement Concrete (1:3:6) type C1 using 20mm graded aggregate as in base or in bed block or hold fast all as specified and directed.
M&L for PCC 1:2:4 (using 12.5mm graded aggr) in roof Kerbs, rounded or chamfered or haunching in chajjas to prevent water seepage into brick walls, including necessary formwork and scaffolding up to a height of 8mtr including demolition of existing PCC all as specified and directed.
M & L PCC 1:3:6 type C2 100mm thick (using 40mm graded aggregate) as in sub base finished the concrete surface even and smooth without using extra cement complete all as specified and directed.
M&L 75 mm thick PCC 1: 3:6 type C2 using 20mm graded agg finishing even and smooth without using extra cement as in plinth protections/path and laid fair in alternate bays n including filler joints with sealing compound grade 'A' complete all as specified and directed.
M&L PCC 1:2:4 type B-1, (using 20mm graded aggregate) 75mm as in plinth protection and finished even all as specified
M&L for 40mm PCC 1:2:4 (Type B0) Damp proof course to horizontal or vertical surfaces including necessary formwork all as specified and directed.
M&L for Cement concrete 1:3:6 type C2 (using 40 mm graded crushed stone aggregate) as in surface channels, drains including all necessary form work complete all as specified and directed.
M&L extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitered/ stopped ends etc complete all as specified and directed.
Demolition of brick work built in cement mortar including pillar etc below/ above ground level etc and removing to a distance not exc 50 meter, complete all as specified and directed by Engr-in-Charge.
M&L for brick work sub class 'B' bricks, straight or curved on plan, exc 6m mean radius built in CM 1:6 complete all as specified and directed.
Material and labour for burnt modular brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar ( 1:6) all as specified and directed.
Taking down cement plastering on brick or stone walls etc, including raking out joints, hacking for key scrubbing down with water etc.
M&L rendering 15 mm thick cement plaster on brick wall in CM 1:4 mixed with WPC @ 3% by weight of cement and finished even and smooth without using extra cement complete all as specified and directed. (Note : WPC will be measured and paid for separately)
M&L 10mm thick rendering in cm (1:6) on fair faces of brick work or concrete surfaces and finished even and smooth without using extra cement, complete all as specified and directed.
M&L for 5 mm thick rendering in cement mortar 1:3 on concrete surfaces as on ceiling and finished fair and even complete all as specified and directed.
Supply only water proofing compound. Conforming to IS -2645, complete all as specified and directed.
M&L preparation of newly plaster surfaces and applying two coats of Acrylic exterior emulsion (Anti fungal) over a coat of primer including one coat of 1 mm thick wall care putty as per manufacturer and applied by approved applicator, complete all as specified and directed.
M&L Applying two coats of Acrylic emulsion distemper to newly plastered/ previously untreated wall over a coat of 1 mm layer wall care putty over a coat of primer by smart painting method including preparation of newly plastered wall all as specified and directed.
M&L Applying one coat of Acrylic emulsion distemper by smart painting method to old wall surfaces of walls and cornices including preparation of old plastered or un plastered of surface of wall by booming down or steel wire brushing ,scraping down smoke soot ,moulds ,moss and efflorescent salts and trading oil and greasy spot all as specified and directed
M&L Applying two coat of Acrylic emulsion distemper with a coat of primer by smart painting method to old wall surfaces of walls and cornices all as specified and directed
M&L complete removal of existing treatment and applying two coats of Acrylic exterior emulsion (Anti fungal) over a coat of primer including method to old plastered walls as per manufacturer instruction including properly fillings the cracks complete all as specified and directed.
M&L for 1 mm thick wall care putty including even and smooth surface after complete removal of existing treatment complete all as specified and directed by Engr-in charge .
Material and labour for preparation of new and previously un-treated wood and wood base surfaces of any description, not otherwise described over 10cmwidth or girth and applying two coats of synthetic enamel paint over one coat of pink primer all as specified and directed.
M&L preparation of new steel surface and applying two coats of synthetic enamel paint over one coats of red oxide preparation of new surfaces over 10 cm width on girth.
M&L for applying for preparation of old painted surfaces of wood and wood base surfaces of any description , not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint all as specified and directed.
M&L for applying for preparation of old painted surfaces of old painted steel surfaces and iron surfaces of any description ,over 10cm width or girth applying one coat of synthetic enamel paint all as specified and directed.
Material and labour for applying three coats of white wash on walls including preparation of new or previously untreated surfaces all as specified and directed.
M&L for preparation of new plastered or unflustered surfaces of ceiling and applying three coats of white wash as in ceiling complete all as specified and directed.
M&L one coat of white wash on old wall surfaces of walls and cornices including preparation of old plastered or un plastered of surface of wall by booming down or steel wire brushing ,scraping down smoke soot ,moulds ,moss and efflorescent salts and trading oil and greasy spot all as specified and directed
M&L one coat of white wash on ceiling and cornices including preparation of old plastered or un plastered of surface of ceiling by booming down or steel wire brushing ,scraping down smoke soot ,moulds ,moss and efflorescent salts and trading oil and greasy spot all as specified and directed
Supply and fix, as in repair,15 mm bore pillar tap, fancy type cast copper alloy, with cap stair head, chromium plated, screwed down high pressure, with or without letter Hot or Cold with long screwed shanuls and fly nuts, screwed for iron pipe or for brass ferrule all as specified and directed.
Supply and fix, as in repair, 15 mm bore bib taps, cast copper alloy,cromium plated, fancy type, with crutch or butter fly handle, screwed down, screwed for iron pipe or for brass ferrule all as specified and directed.
Supply and fix, as in repairs, vitreous china squatting pan of Orissa pattern size 580mm x 440 mm, white, with integral foot rests (excluding flushing cistern and flush pipe) including connection making good to floor all as specified and directed.
Supply and fix, bowel urinal flat back of size 465 x 355 x 265mm (minimum), white, with grating and union for discharge pipe, (excluding flushing cistern, flush pipe and waste pipe) complete including providing and fixing plugs, bedding urinals against wall in cement mortar (1:2) securing urinals to plugs with and including 60 mm brass screws and pointing around urinals back in cement all as specified
S&F in repair brass chromium plated towel rail 600 mm long complete all as specified and directed.
S&F in repair Soap dish, any type, fixed to plugs with chromium plated brass screws complete all as specified and directed.
S&F in repair Towel Ring of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90gms) complete all as specified and directed.
Supply and fix, as in repair, stop valve, cast copper alloy, fancy type, chromium plated with long shank and cup (concealed type) screwed down high pressure, with crutch or butterfly handles for 15 mm bore pipe or for unions all as specified and directed.
S&F in repairs stop cock cast copper alloy, fancy type ,chromium plated, screwed down, high pressure, with crutch of butterfly handle screwed both ends to iron pipe of size 15mm, all as specified and directed.
S&F in repairs angle cock 15mm bore, two way, chromium plated, fixed to GI or steel tubing incl fittings complete all as specified and directed.
Supply and fix, as in repair, vitreous china wash basin, white, flat back size 580 x 450 mm, excluding taps, waste chain, plug and porcelain stopper but including brackets, cutting for and pinning in ends of bracket or erecting stand complete all as specified and directed.
Supply and fix, as in repair, sinks with drainage board made out of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes, including bedding in cement mortor to dwarf wall or including fixing contriver lever brackets and connecting union to pipe overall size 915mmX460mm and bowl size 410mmX330mmX160mm all as specified and directed. Make - Blue star/ Prayag/ NIRALI (all ISI marked)
Supply and fix, as in repair, waste coupling CP 32 mm dia for glazed ware basins etc with fly nuts flanged etc complete all as specified and directed.
Supply and fix, as in repair, 32 mm dia PTMT 610 mm long waste pipe suitable for WHB complete all as specified and directed.
Supply and fix, as in repair, CP 40mm dia waste coupling with inlet and out let screwed for pipe or connections including packing, union and cap etc complete all as specified and directed.
Supply and fix, as in repair, 40 mm dia PVC 610 mm long waste pipe suitable for complete all as specified and directed.
S&F in repairs grating 100mm dia of PTMT (minimum weight 25 gms) all as specified and directed.
Supply and fix, as in repair, Overhead Shower 100 mm dia Round Shape Single Flow (Brass Chromium Plated) with Rubit Cleaning System, including fixing to steel pipe or union of 15mm bore all as specified and directed. Make : ECCO/ Hindware
Supply and fix, as in repair, 10 ltrs capacity PVC valve less symphonic action type, low level flushing cistern, white, with inlet, ball valve float and handle including brackets & flush pipe of polyethylene of low or high density or PVC 32 mm dia complete all as specified and directed.
Supply and fix, as in repair,15 mm dia 600 mm long connection pipe with two PVC PTMT nuts at each ends with rubber washer complete all as specified and directed.
Supply and fix, as in repair, steel handles for steel window for left and right side shutter all as specified and directed
Taking up or down 15 mm bore old steel tubing and connections, including disconnection of fittings from tubing including cleaning for re-fixing or removal from site complete all as specified and directed.
All as per item No 111 here in before but 20 mm bore all as specified and directed
S&F of 15 mm bore tubes medium grade galvanised with and incl all GI fitting (such as bends, elbows, Tees, connectors, short pieces, back nuts, unions, caps and plug etc ) and fixed complete to wall and ceiling or laid in/on floor complete all as specified and directed,
All as per item No 113 here in before but 20 mm bore all as specified and directed
Supply and fix, as in repairs, 75 mm dia of outlet PVC(SWR) floor trap, plain with granting including jointing with solvent cement all as specified and directed
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories)
Supply and fix, 110mm bore PVC (SWR)pipe single socketed with rubber ring joints fixed to walls all as specified and directed.
S&F in repairs PVC (SWR) 110mm dia bends any radius all as specified and directed.
S&F in repairs PVC (SWR) branch 110mm bore pieces, single ( single Y ) equal or unequal all as specified and directed.
S&F in repairs PVC (SWR) junction110mm bore single ( single t) equal or unequal all as specified and directed.
Supply and fix, PVC cowls 110 mm bore all as specified and directed.
Supply and fix, 75 mm bore PVC (SWR)pipe single socketed with rubber ring joints fixed to walls all as specified and directed.
S&F in repairs PVC (SWR) 75 mm dia bends any radius all as specified and directed.
S&F in repairs PVC (SWR) branch75 mm bore pieces, single ( single Y ) equal or unequal all as specified and directed.
S&F in repairs PVC (SWR) junction75 mm bore single ( single t) equal or unequal all as specified and directed.
Supply and fix, PVC cowls 75 mm bore all as specified and directed.
S&F Stack clamps including bolts and nuts and securing ends of stays to wall or roof for 100/75mm bore complete all as specified and directed.
Demolition of reinforced cement conc of any description and in any position, complete all as specified and directed.
M&L pre cast RCC (1:2:4) type B1 using 20 mm graded stone aggregates for cover slab of manhole/soak pit etc set in cement mortar 1:4 complete all as specified and directed.
M&L Reinforced cement concrete 1:1.5:3 (Type A1) (20 mm aggregate) including rafts footings, foundation beams, plinth beam base for column etc basement slab, under reamed piles and mass concrete all as specified and directed.
M&L Reinforced cement concrete 1:1.5:3 (Type A1) (20 mm aggregate) including Beams, cantilevers, bressummers, lintels over 1.5m span complete.
M&L Reinforced cement concrete 1:1.5:3 (Type A1) (20 mm graded aggregate) as in column, pillar, pier, posts etc complete all as specified and directed.
M&L Reinforced cement concrete 1:1.5:3 (Type A1) (20 mm graded aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed.
M&L Reinforced cement concrete 1:1.5:3 (Type A1) (20 mm graded aggregate) as in chajjas etc complete all as specified and directed.
Use & waste form work for flat fair finished surfaces of concrete foundation, footings, bases of columns and plinth beam and similar work for rough finished flat surfaces of concrete , complete all as specified and directed.
Use & waste form work to sides of pillars, posts, struts, piers, columns and stanchions of square, rectangular on polygonal shape for rough finished surfaces of concrete, complete all as specified and directed.
Use & Waste of Formwork to chullah hoods, chajjas, troughs and similar items including edges of rough finished flat surfaces of concrete, complete all as specified and directed.
Use & Waste of Formwork to sides and soffits of floor or roof beam , beam haunching, girders ,lintels shelves inclosing support and hangs, complete all as specified and directed.
Use and waste formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) as in rough finished surfaces of concrete all as specified and directed.
S&F TMT bar 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and directed.
M&L Mild steel bars 5mm dia and over up to and including 10mm dia in stirrups, spacers and binders cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
M&L Polythene film, 50 micron thick, laid on a coat of bitumen primer, @ 0.30 to 0.50 kg per sq. m all as specified and directed.
M&L for Concrete bed to drain pipes including packing under and completely surrounding pipes with concrete after they are laid and tested; dia of pipe 150mm in PCC 1:3:6 type C2 all as specified and directed.
M&L laying salt glazed stoneware drain pipe conforming to IS 651-1972 grade ‘A’ in trenches and jointed in cement mortar (1:1) for 150 mm internal diameter of pipes complete all as specified and shown on drawings, complete all as specified and directed.
M&L Cutting into existing manholes for connecting new drains, making good to 150mm pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required, complete all as specified and directed.
Supply and fix15 mm dia 600 mm long connection pipe with two PVC PTMT nuts at each ends with rubber washer complete all as specified and directed.
S&F vitreous China Wash Basin, white, flat back of size 550 x 400 mm including suitable size of GI brackets, brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed complete all as specified and directed.
S&F Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed to 20mm bore steel tube, complete all as specified and directed.
S&F in replacement LED street light fitting 35 watt 230 volt, AC outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, complete all as specified and directed.Make-Havells,Cat No-ENDCITYLITPLAT+SL35WLED757SASYBOPCWOSPD / Surya Cat log No. SLE UL 30W IP66 LXN.
S&F in replacement LED street light fitting 60 watt 230 volt, AC outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, complete all as specified and directed.Make-Havells,Cat No-ENDURAPEARLNEOSL60WLED757PASYTOPCAST / Surya Cat log No. SLE UL 60W IP66 LXN.
S&F in replacement LED street light fitting 70 watt 230 volt, AC outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, complete all as specified and directed.Make-Havells,Cat No-ENDURAPEARLNEOSL70WLED757PASYTOPC / Surya Cat log No. SLE UL 72W IP 66 LXN.
S&F in replacement LED street light fitting 90 watt 230 volt, AC outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, complete all as specified and directed.Make-Havells,Cat No-ENDURAOMNIPLUSSL90WLED757SASYTOPC / Surya Cat log No.SLE UL 90W IP66 LXN.
S&F in replacement 70 Watt LED floodlight ,IP 66 ,230Volt, AC, outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp, complete all as specified and directed.Make-Havells,Cat No-JETAALBAFLOODLIGHT70W / Surya Cat log No. SLE FL 80W IP 66 LIVIA.
S&F in replacement 120 Watt LED floodlight ,IP 66 ,230Volt, AC, outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp, complete all as specified and directed.Make-Havells,Cat No-JETAIRISFL120WLED757ARWBLTG / Surya Cat log No. SLE FL 120W IP66 LIVIA.
M&L in replacement supports clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint all as specified and directed.
Supply and fix in replacement 3 core 1.5 sqmm multistranded PVC insulated flexible copper cable FRLS grade including required PVC Conduit to protect the cable all as specified and directed.
S & F in replacement 8W LED outdoor new generation landscape lighting fitting Bamboo type with 1mtr length IP 65/66 protection including base to stand alone complete all as specified and directed.Make-Havells,Cat No-BAMBOOBLS8WLED830PSYMTOPC / Surya Cat log No. SLE BL 9W-BLK800.
S & F in replacement 8W LED outdoor new generation landscape lighting fitting Cone type with IP 65 protection including base to stand alone complete all as specified and directed.Make-Havells,Cat No-CONEBLS8WLED830PSYMTOPC / Surya Cat log No.SLE BL 9W IP65 HARY 750.
S & F in replacement 25W LED outdoor New generation, post-top, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminum landscape luminaries with high power LEDs as light source with IP 65 protection complete all as specified and directed. Make-Havells, Cat No-RUBYPT25WLED830SSYMTOPC / Surya Cat log No. SLE PT 30W ETPP.
Supply, Laying ,testing, and commissioning in replacement of size 4x16 sqmm cross-sectional area XLPE insulated,armoured heavy duty electric cable with aluminum conductor 1100 volts grade, in tranches / fixing on wall by saddle/ fixing on poll / drawn through GI pipes all as specified and directed.
All as in Item No 160 above but for cable 4 x 10 Sqmm all as specified and directed.
All as in Item No 161 above but for cable 4 x 6 Sqmm all as specified and directed.
M&L for sub class 'B' brick for protection of UG cable in tranches of old size brick all as specified and directed.
S&F in replacement pathway light with powder coated aluminum housing with wide light distribution, 45 watt, 230 volt. Make: Wipro Model No VISTA LP09 (Cat No : LP09-501-xxx-57-xx) Or equivalent in Philips/ Havells/Bajaj.
Supply and fixing in replacement of Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65 mm dia for working pressure 1100 volts grade complete all as specified and directed .
Supply and fixing in replacement of Shackle Type, Porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts, suitable for 1100 Volts, Height 100 mm, Width 115 mm including galvanised strap 31 x 5 mm, Nut bolts 14 mm and Washer 3 mm thick as under: complete all as specified and directed.
Supply and fixing in replacement of Automatic street light control switch Panel complete with, complete all as specified and directed. a) Infrared sensor based Nature Switch for automatic switching of street lights. Nature switch operation should be based on Natural light Lux level. Required luminance level for switching ON is less or equal to 30 Lux and for switching OFF 10 Lux. The sensor should also have part night operation facility of minimum 4 hrs to maximum 12 hrs. - 01 No. Make Of Sensor: L&T/SIEMENS/ HPL/ C&S/ Wipro/Bajaj/Healer. b) Power contactor two pole, 230 volts, 63 Amp capacity, confirming to IEC-60947-4-1. - 01 No. Make:- BCH/L&T/Schneider. c) The sensor along with suitable power contactor and incoming outgoing MCBs should be enclosed in a pole/ wall mountable rust proof, electric shock proof, termite proof and FR grade Thermoplastic polycarbonate enclosure (with hinged lid) confirming to IP66 protection class 2 of suitable size to accommodate all panel accessories. -01 Job. Make:- Hensel/Syntax or equivalent. d) MCB SP 63 Amp, B Curve, Confirming to IEC-60898/IS8828. -02 Nos. Make: Hager/Schneider/L&T. e) All control cable wiring inside the panel should be of copper conductor, multistandard, PVC insulated, FRLS, 1100 volts grade, of size 10 sq mm, single core, followed by colour coding and lugs/thimbles. Make: Finolex/Polycab/Plaza. (All ISI marked) f) All equipments are mounted on suitable size insulators. Make Of Complete Panel: Healer Enterprises, Model No: Swadeep-66-8KW1P. Or Equivalent.
S & F in repair power Contactor , 2 pole 40 A,230 volts, of make L&T model no MNX 40-2P or equivalent in ABB, Schneider complete all as specified and directed.
S&F in replacement nature switch (sensor Only), Infrared sensor based Nature Switch for automatic switching of street lights. Nature switch operation should be based on Natural light Lux level. Required luminance level for switching ON is less or equal to 30 Lux and for switching OFF 10 Lux. The sensor should also have part night operation facility of minimum 4 hrs to maximum 12 hrs, complete all as specified and directed.
S & F in replacement PVC pole mounted loop in loop out box 210 x 310 x 116 mm made of impact resistance plastic and heat resistance material including 01 No 06A SP MCB, 04 Nos 100A rating bus bar mounted on insulators and all cable fixed with suitable lugs and suitable Cable Glands complete all as specified and directed. Note : (a)The rate of Materials for fixing like MS clamps, nuts, bolts & washers are deemed to be included in the unit price . (b) labour for fixing of MS clamps, nuts & bolts shall deemed to be included in unit rates. (c) Unit rate shall include the connection between existing incoming LT cable lines to new junction box . Make for loop in loop out box : Hensel/Sintex
S & F in repair PVC loop in loop out box 139x119x70 mm made of impact assistance plastic and heat resistance material and all cable fixed with appropriate connector including necessary PCC foundation for landscape light complete all as specified and directed. Note : (a) labour for fixing of nuts & bolts shall deemed to be included in unit rates. (b) Unit rate shall include the connection between existing incoming LT cable lines to new junction box . Make for loop in loop out box : Hensel/Sintex
M& L for Pole painting of steel tubular swaged pole with two coat of aluminum paint after two days applying one coat of synthetic enamel paint with alternate strips of black and yellow paint strip of 25 CM up to 1.5 mtr at bottom of the pole & writing the pole number all as specified and directed.
Supply and Fix in replacement 63 Amps MCCB, 4 pole, 16 KA "C" series 415 Volt, adjustable overload setting 0.8-1 x In complete all as specified and directed.
Supply and fix MCCB 4 pole, microprocessor based Release range 100 Amps to 250 Amps,415V,AC,50Hz ,36 KA Manual versions With Conforms to IS/IEC 60947-2,Ics=100% Icu,Suitable for Isolation Adjustable Over Load setting: 0.4 - 1.0 x In ,Adjustable Short Circuit setting: 1.5 - 10 x Ir , ,Wide Range of snap fit Internal and External Accessories including Taking down old MCCB all as specified and directed. Make - Siemens/L&T/Schneider/ABB.
All as in Item No-175, but for 45 to 60 watt, complete all as specified and directed.
M & L Earthling in replacement for complete with GI earth plate electrode 60cmX60cmX6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connecting to galvanized earth strip 32 x 6 mm as earthling conductor by means of bolts, nuts, check nuts and washers of GI and all as shown in Electrical plate No.3 of SSR Part I and including testing on completion all as specified locations and directed. Note: 1.The above quoted rate shall include cost of main earthling lead of 32 x 6mm GI earth strip, charcoal, salt, excavation and earth work in any type of soil CI cover, funnel with 20mm dia light grade GI water pipe including GI protection pipe 40mm dia light grade for earth strip etc. 2. The cost of earth pit is deemed to be included in the unit rate.
M & L for replacement for Earthling complete with GI earth plate electrode 60cmX60cmX6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connecting to galvanized earth wire 4 mm as earthling conductor by means of bolts, nuts, check nuts and washers of GI and all as shown in Electrical plate No.3 of SSR Part I and including testing on completion all as specified locations and directed. Note: 1.The above quoted rate shall include cost of main earthling lead of dia 4mm GI earth wire, charcoal, salt, excavation and earth work in any type of soil CI cover, funnel with 20mm dia light grade GI watering pipe including GI protection pipe 15mm dia light grade for earth wire etc up to 7.5 mtr length. 2. The cost of earth pit is deemed to be included in the unit rate.
M & L in replacement Air termination, single pointed, copper rod 12mm dia and 300mm long complete all as specified and directed.
M & L in replacement Air termination, single pointed, Aluminum rod 12mm dia and 300mm long complete all as specified and directed
M & L in replacement Air termination multi spike of copper material of height 0.9 meter length complete all as specified and directed.
Refixing existing GI/Aluminum lightning Strip of any size including insulating saddles and fixing screws including taking down old unsv saddles and screws complete all as specified and directed.
M & L in replacement 32 x 6 mm GI strip fixed to wall on batten or on roof or recess or chases or buried in ground of size complete all as specified and directed.
M & L in replacement Copper strip 20 x 3.15 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed
S & F in repairs Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed
Taking down old unserviceable Earthling of any type including all its accessories complete all as specified and directed
S&F in replacement Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts and nuts as specified type 410 SP-22, 8.5 meters long all as specified and directed.
Supply and fix in replacement Galvanised steel wire 3.15 or 4 mm dia GI wire, in continuous earth wire on poles, all as specified and directed.
M&L in replacement for GI pipe medium grade street light bracket of 40 mm dia, of length 1.5 mtr length, bend/weld to 60 degree (1 mtr straight and 0.5 mtr bend), all as specified and directed.
Supply and fix GI pipe of dia 50mm to wall/Pole of medium grade with required clamping arrangements to fix with the pole complete and connecting to the existing pipe line all as specified .
Shree Krishna Traders
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .