Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.5 CrAccepted-AOC MANATHA ENCLAVE 3RD FLOOR OLIMUGAL KAKKANAD P O KOCHI 682 030 KERALA | ERNAKULAM | KERALA | 682030 | ₹7.5 Cr Quoted ₹7.6 Cr | L1 | Accepted-AOC ACCEPTED BEING L1 |
| 2 | L2₹8.5 Cr+₹92.8 L (12.3%)Rejected-AOC | ₹8.5 Cr+₹92.8 L (12.3%) | L2 | Rejected-AOC REJECTED BEING L2 |
| 3 | L3₹8.6 Cr+₹99.9 L (13.2%)Rejected-AOC THOTTAPPALLY HOUSE EMILY KALPETTA P O KERALA 673121 | WAYANAD | KERALA | 673121 | ₹8.6 Cr+₹99.9 L (13.2%) | L3 | Rejected-AOC REJECTED BEING L3 |
| 4 | L4₹8.9 Cr+₹1.3 Cr (17.7%)Rejected-AOC GP KIZHAKKAMBALAM KOLENCHERY | THRISSUR | KERALA | 680667 | ₹8.9 Cr+₹1.3 Cr (17.7%) | L4 | Rejected-AOC REJECTED BEING L4 |
| 5 | L5₹9.4 Cr+₹1.9 Cr (24.8%)Rejected-AOC EBENEZER C C33 1185A CHALIKAVATTOM VENNALA P O KOCHI KERALA 682 028 | ERNAKULAM | KERALA | 682028 | ₹9.4 Cr+₹1.9 Cr (24.8%) | L5 | Rejected-AOC REJECTED BEING L5 |
Tender Value
Refer Docs
EMD Value
₹7.8 L
Closing Date
12 May 2022, 6:00 pmClosed
CE NW Kochi
Kataribagh, Naval Base, Kochi-04
ADDN/ALTN AND SPECIAL REPAIRS TO VISWANATHAN BUILDING (P-5)AT DHARAMVIR ENCLAVE PANAMPILLY NAGAR KOCHI
2022_MES_513069_1
891010
Open Tender
Civil Works
Item Rate
540 days
Kochi
As per NIT
8 documents required · 8 mandatory
₹3,000
GE NW Kochi
₹7.8 L
Yes
8 Jun 2022
10 Mar 2022
14 May 2022
11 Mar 2022
12 May 2022
5 May 2022
11 Mar 2022 - 19 Mar 2022
Amount
SCHEDULE 'A' B/R WORKS
Taking down cement plaster on brick or stone walls or on concrete surface etc including raking out joints, hacking for key, scrubbing down with water, etc upto IV th sotery complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 2 herein before but V th storey and above up to VIII th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 02 herein before but IX th storey and above up to XII th storey complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for Two layer plaster with first coat 8mm thick in CM 1:4 plastering and over 12mm thick plaster with WPC cement mortar 1:6 all as specified and directed up to IV th storey complete all as specified and as directed by Engineer-in-Charge. Note:- Water proofing compound shall be measured and paid seperately
All as per Item No 5 herein before but for V th storey and above up to VIII th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 05 herein before but for IX th storey and above up to XII th storey complete all as specified and directed by Engr-in-Charge.
Material and Labour for Applying two coats of weather proof (antifungal) paint on new surfaces of wall over and including a coat of antifungal primer and one coat of sealant base coat by authorised applicator or under company supervision up to IV th storey complete all as specified and directed by Engineerr-in-Charge.
All as per Item No 08 herein before but for V th storey and above up to VIII th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 08 herein before but for IX th storey and above up to XII th storey complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for Rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM 1:4 as in jambs finished even and smooth without using extra cement upto 4th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 11 herein before but for 5th to 8th storey complete all as specified and as directed by Engineerr-in-Charge.
All as per Item No 11 herein before but for 9th to 12th storey complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for 10mm thick rendering on fair face of brick work or concrete surface with cement mortar 1:6 finished even and smooth without using extra cement from Ground floor to 4th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 14 herein before but for 5th to 8th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 14 herein before but for 9 to 12th storey complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for 5mm thick rendering on fair face of concrete ceiling surface with cement mortar 1:3 finished even and smooth without using extra cement from Ground floor to 4th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 17 herein before but for 5th to 8th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 17 herein before but for 9th to 12th storey complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for 15mm thick rendering on fair face of brick work or concrete surface with cement mortar 1:6 finished even and smooth without using extra cement from Ground floor to 4th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 20 herein before but for 5th to 8th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 20 herein before but for 9th to 12th storey complete all as specified and as directed by Engineer-in-Charge.
Supply only Integral water proofing compound complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for Preparation of new plastered surfaces of walls and applying two coats of washable distemper over a coat of Alkali resistance primer over and including 2mm putty from ground floor to 4th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 24 herein before but for 5th to 8th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 24 herein before but for 9th to 12th storey complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for Preparation of new plastered surfaces of ceiling and applying two coats of washable distemper over a coat of Alkali resistance primer over and including 2mm putty from ground floor to 4th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 27 herein before but for 5th to 8th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 27 herein before but for 9th to 12th storey complete all as specified and as directed by Engineer-in-Charge.
Demolition of PCC in ground floors and pavings n.exc 15 cm thickness(below or above GL) un re-inforced from ground floor to fourth floor complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 30 herein before but for 5th to 8th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 30 herein before but for 9th to 12th storey complete all as specified and as directed by Engneer-in-Charge.
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc complete from Ground floor to 4th storey all as specified and directed by Engineer-in-Charge.
All as per Item No 33 herein before but for 5th to 8th storey complete all as specified and directed by Engineer-in-Charge.
All as per Item No 33 herein before but for 9th to 12th storey complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Screed bed or bedding layer of mortar 15mm thick for laying floor finishes in CM 1:4 from Ground floor to 4th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 36 herein before but for 5th to 8th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 36 herein before but for 9th to 12th storey complete all as specified and as directed by Engineer-in-Charge.
Material and Labour 25mm thick floor PCC 1:2:4 type B-0(using 12.5mm graded stone aggregate) finished even and fair for laying floor tiles from Ground floor to 4th storey complete all as specified and directed by Engineer-in-Charge.
All as per Item No 39 herein before but for 5th to 8th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 39 herein before but for 9th to12th storey complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for Vitrified ceramic tiles ,light shade,9-10mm thick ultra charge/Double charge(square/rectangular)polished area of each tile exc 0.42Sqm but not exc 1Sqm in floors set jointed in neat cement slurry and pointed in white or coloured cement to match complete from Ground floor to 4th storey all as specified and as directed by Engineer-in-Charge.
All as per Item No 42 herein before but for 5th to 8th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 42 herein before but for 9th to 12th storey complete all as specified and directed by Engineer-in-Charge.
All as per Item No 42 herein before but on skirting from ground floor to IV th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 45 herein before but for 5th to 8th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 45 herein before but for 9th to 12th storey complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for Non - skid Ceramic tiles coloured 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11Sqm but not exceeding 0.18Sqm in neat cement slurry and pointed in white or coloured cement to match complete from Ground floor to 4th storey all as specified and directed by Engr-in-Charge.
All as per Item No 48 herein before but for 5th to 8th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 48 herein before but for 9th to 12th storey complete all as specified and as directed by Engineer-in-Charge.
Material and Labour Rendering 10mm thick on fair faces of brick work or concrete surfaces in CM 1:3 to receive wall tiles from Ground floor to 4th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 51 herein before but for 5th to 8th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 51 herein before but for 9th to 12th storey complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for Digital Glazed Ceramic tiles in vertical surface 600 x 300 , 7 to 8 mm thick coloured tiles set and jointed in neat cement slurry and pointed in white or colour cement to match complete from Ground floor to 4th storey all as specified and as directed by Engineer-in-Charge.
All as per Item No 54 herein before but for 5th to 8th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 54 herein before but for 9 to 12th storey complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for Machine cut kota stone slab flooring 18-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing comple in white or colour cement to match complete from Ground floor to 4th storey all as specified and as directed by Engineer-in-Charge.
All as per Item No 57 herein before but for 5th to 8th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 57 herein before but for 9th to 12th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 57 herein before but Kota stone slab 20-25mm thick in riser of steps, skirting, dado complete from Ground floor to 4th storey all as specified and as directed by Engineer-in-Charge.
All as per Item No 60 herein before but for 5th to 8th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 60 herein before but for 9th to 12th storey complete all as specified and as directed by Engineer-in-Charge.
Demolition cement Concrete of any description and in any position in cooking platform ,window cills specifically provided complete from Ground floor to 4th storey all as specified and directed by Engineer-in-Charge.
All as per Item No 63 herein before but for 5th to 8th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 63 herein before but for 09th to 12th storey complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Screed bed or bedding layer of cement mortar 20mm thick for laying floor finishes in CM 1:4 complete from Ground floor to 4th storey all as specified and as directed by Engineer-in-Charge.
All as per Item No 66 herein before but for 5th to 8th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 66 herein before but for 9th to 12th storey complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for Marble slab 18 to 20mm thick (table rubbed and polished) in steps, jambs, pillars, window cills and like including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade of Makrana doogri complete from Ground floor to 4th storey all as specified and as directed by Engineer-in-Charge.
All as per Item No 69 herein before but for 5th to 8th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 69 herein before but for 9th to 12th storey complete all as specified and as directed by Engineer-in-Charge.
Material and Labour for Granite (of any type) 20 mm thick (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete from Ground floor to 4th storey all as specified and as directed by Engineer-in-Charge.
All as per Item No 72 herein before but for 5th to 8th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 72 herein before but for 9th to 12th storey complete all as specified and as directed by Engineer-in-Charge.
Taking down chowkats or frames with shutters (with out taking off shutters from the frames) not exc 1.5Sqm each complete from Ground floor to 4th storey all as specified and directed by Engr-in-Charge.
All as per Item No 75 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 75 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 75 herein before but exc. 1.5Sqm but not exc 4Sqm each from Ground floor to 4th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 78 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 78 herein before but for 9 to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix Powder coated aluminium(minimum thickness of powder coating 50 micron)for shutters of doors, windows and ventilators including providing and fixing hinges/pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required(fittings shall be paid for seperately) with extruded built up standard tublar sections/approriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasterners of required dia and size, including necessary filling up gaps at junctions, i.e at top, bottom and sides with required EPDM rubber/gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/panelling, C.P brass/stainless steel screws all complete from Ground floor to 4th storey all as specified and directed by Engr-in-Charge. Note:- Glazing will be measured and paid seperately.
All as per Item No 81 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 81 herein before but for 9 to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix factory made uPVC (White colour) Three track three panells sliding window with fly proof SS wire mesh with provision for grill fixing(Two Nos glazed and one No wire mesh panels)upto 1.5m height made of (big series)frame not less than 116mm x 45mm and sash not less than 46mm x 62mm both having wall thickness of 2.3 plus or minus 0.2mm and single glazing bead/double glazing bead of appropriate dimension. (Area of window above 1Sqm)comprising of uPVC multi chambered frame with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 plus or minus 0.2mm thick galvanized mild steel section made from roll forming process of reqired length(shape & size according to uPVC profile)appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy(white powder coated) touch locks with hook, zinc alloy body with single nylon rollers(weight bearing capacity to be 40Kg), GI fasterners 100mmx8mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame and sash shall be mitred cut and fusion welded at all corners, incluidng drilling of holes for fixing hardware,s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality complete from ground floor to fourth floor all as specified and as directed by the Engineer-in-Charge.(Glass or wire mesh/decogrill shall be measured and paid seperately)
All as per Item No 84 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 84 herein before but for 9 to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and Fix Anodised aluminium decorative grills powder coated window grills not exc 2.07Kg /Sqm conforming to IS 1368 minimum anodic coating of grade AC15 from Ground floor to 4th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 87 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 87 herein before but for 9 to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix Sheet glass ordinary quality 4mm thick and glazing with aluminium beads to aluminium windows in square not exc 0.5Sqm in each pane from Ground floor to 4th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 90 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 90 herein before but for 9 to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix Sheet glass ordinary quality 5.5mm thick and glazing with alu minium beads to aluminium doors in square exc 0.5Sqm in each pane from Ground floor to 4th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 93 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 93 herein before but for 9 to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples from Ground floor to 4th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 96 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 96 herein before but for 9 to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix UPVC ventilators with fixed type wire nett shutter and louvers frosted glass 4mm thick complete with using following sections (i) Outer frame 50.80x25.40x1.5mm (ii) shutter frame 31.80x14.50x1.20mm from Ground floor to 4th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 99 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 99 herein before but for 9 to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix Pressed steel frames 105mm x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate,etc.upto 4th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 102 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 102 herein before but for 9 to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix Pressed steel frames 125mm x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate,etc.upto 4th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 105 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 105 herein before but for 9 to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix 35mm thick flush shutters, solid core construction with block board core covered with decorative face veneers with lipping/frame to match complete from Ground floor to 4th storey all as specified and directed by Engr-in-Charge.
All as per Item No 108 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 108 herein before but for 9 to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix 25mm thick flush window shutters solid core construction with block board core covered with decorative face veneers with lipping around 25mm thick with sliding arrangement and bolting system including stainless steel channel and bolting system upto fourth storey complete fixed to two track aluminium frame all as specified and as directed by Engineer-In-Charge.
All as per Item No 111 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 111 herein before but for 9 to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix Second Class Hardwood 35mm thick glazed and skelton shutters, open rebated and prepared to receive glass gauge etc., divided into squares, with plain, chamfered or rounded mitred and rebated sash bars, any numbers, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc size of members of shutters as specified in SSR Pt-I, Sec 8, clause 8.20 (a) from Ground floor to 4th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 114 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 114 herein before but for 9 to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix Solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tubes upto fourth storey , supplying and fixing as per specification and Drg complete all as specified and as directed by Engineer-In-Charge.
All as per Item No 117 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 117 herein before but for 9 to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail;Panelling of plain colour PVC sheet to befitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing from Ground floor to 4th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 120 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 120 herein before but for 9 to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix Stainless steel butt hinges 100mm long upto 4th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 123 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 123 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix Aluminium anodised barrel tower bolt of extruded section, length of bolt 150 mm from Ground floor to 4th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 126 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 126 herein before but for 9 to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix Extruded aluminium alloy handles fabricated type anodised of size 150 mm upto 4th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 129 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 129 herein before but for 9 to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix Aluminium alloy anodised sliding door bolt 300mm long with hasp, staple (bolt type) and fixing clips of sheets cast or extruded sections or cast aluminium alloy upto 4th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 132 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 132 herein before but for 9 to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix Aluminium alloy anodised sliding door bolt 150mm long with hasp, staple (bolt type) and fixing clips of sheets cast or extruded sections or cast aluminium alloy from Ground floor to 4th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 135 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 135 herein before but for 9 to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix MS door spring 300mm, ordinary rat rail rod pattern springs including roller and roller plate from Ground floor to 4th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 138 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 138 herein before but for 9 to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix Floor door stopper of aluminium alloy body and tongue anodised with hard drawn steel spring fixed in floor overall length of cover plate 150 mm from Ground floor to 4th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 141 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 141 herein before but for 9 to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix Mortice lock vertical type size 100 mm, 4 levers of brass from Ground floor to 4th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 144 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 144 herein before but for 9 to 12th storey complete all as specified and directed by Engr-in-Charge.
Material and Labour for Preparation of new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer from Ground floor to 4th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 147 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 147 herein before but for 9 to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix Door outside viewer for safety of Entrance doors, suitable for residential of make : RiseOm Door Eye/Door Peephole 180 Defree Viewer Made of Brass or equivalent make as listed in CA from Ground floor to 4th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 150 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 150 herein before but for 9 to 12th storey complete all as specified and directed by Engr-in-Charge.
Cutting openings, through brick walls built in cement mortar for door, window and other openings or enlarging existing openings.converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks,removing surplus serviceable bricks, hard-core,etc.. to store and rubbish not exc. 50m Ground floor to 4th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 153 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 153 herein before but for 9 to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix MS window grills framed works with ends of bars shouldered and or riveted or forged into spikes and similar work conforming to Fe.290.Gde-E-165 from Ground floor to 4th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 156 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 156 herein before but for 9 to 12th storey complete all as specified and directed by Engr-in-Charge.
Material and Labour for Preparation of new or previously untreated steel surfaces of any description over 10 cm width or girth and applying two coats of Anti corrosive paint over a coat of red oxide primer from Ground floor to 4th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 159 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 159 herein before but for 9 to 12th storey complete all as specified and directed by Engr-in-Charge.
Material and Labour for cutting chases,pinningin,making good to facing where required and pointing in cement mortar 1:3 for concealed waste water pipe of AC etc and making good cutting n.exc 20cm girth from Ground floor to 4th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 162 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 162 herein before but for 9 to 12th storey complete all as specified and directed by Engr-in-Charge.
Dismantling old pelmet box including cover fillet and brackets and hanging arrangements from ground floor to fourth floor all as specified and as directed by Engineer-In-Charge.
All as per Item No 165 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 165 herein before but for 9 to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix Aluminium high strength decorative PVC coated curtain rails including plastic rings, decorative coupling at both ends and brackets of galvanized steel powder coated paint from Ground floor to 4th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 168 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 168 herein before but for 9 to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix Second class HW plain fillets square or rectangular in section clean sawn, secured with nails but bull nosed, splayed, chamfered or rounded on one edge or face area exc 13Sqcm but not exc 25Sqcm from Ground floor to 4th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 171 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 171 herein before but for 9 to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix 18mm thick rubwood as in CB shutter, shelves etc cut to shape as specified and fixed with screws upto 4th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No174 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 174 herein before but for 9 to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix 12mm thick rubwood as in CB's cut to shape as specified and fixed with screws up to 4th storey complete all as specified and as directed .
All as per Item No 177 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 177 herein before but for 9 to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix Continuous (piano) hinges 30mm wide open flanges , mild steel, bright finish or electro galvanised upto 4th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 180 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No180 herein before but for 9 to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix Magnetic catch for cupboard shutter upto 4th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 183 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 183 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix Stainless steel handles 100mm long for cupboards fixed with stainless screws upto fourth storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 186 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 186 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Material and labour for French polishing on surfaces of any description, width or girth including cleaning and preparing the surface including a coat of wood filler on new works with two or more coats upto 4th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 189 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 189 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix Auto closer counter sunk hinges, stainless steel 100 mm for Cup board doors upto fourth storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 192 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 192 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix Stainless steel tube 20 mm dia with flanges 60 mm length fixing inside cup board upto fourth storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 195 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 195 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix Stainless steel sliding channels 60 cm long with roller for fixing drawers inside cup board upto fourth storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 198 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 198 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix Brass pad lock 2 levers for Cup board upto fourth storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 201 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 201 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix Stainless steel decorative knobs fixing in drawer upto fourth storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 204 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 204 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Material and Labour for 18mm thick marine plywood modular kitchen cabinets, inside depth not less than 0.50M , water proof, termite & borer proof, corrosion free with melamine finished shutter and auto closer counter sunk hinges, stainless steel handles (buff finished) complete all as specified and as directed . Note : (i) Only front facing area of cabinet will be measured for payment. (ii) Stainless steel baskets mentioned as supply only under Sl. item No.210 shall be fixed under this item as the unit rate quoted against this item is inclusive of this fixing provision) all as specified and as directed by Engr-in-Charge.
All as per Item No 207 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 207 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply only a set of stainless steel baskets with fittings as in modular kitchen cabinet as per following details :- (i) Plate basket 21"x19"x8" - 01 No (ii) Plane basket 21"x19"x8" - 01 No. (iii) Plane basket 17"x19"x8" - 01 No. (iv) Butlery basket 17"x19"x4" - 01 No. (v) Cup & Saucer basket 17"x19"x4" - 01 No. (vi) Single pull out 8" - 01 No. (vii) GT- PT & Drip tray 22" - 01 No. (viii) Telescopic channels of appropriate size - 06 Nos.from ground floor to fourth floor complete all as specified and as directed by Engineer-in-Charge ( Make : First quality of Sleek/ Ebco/ Dolin or equivalent make approved)
All as per Item No 210 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 210 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix Locks for cup board, grade-I, size 50 mm of brass 4 levers up to fourth storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 213 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 213 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix Dressing mirror of size 60x150cm approx fixed to wall along with beading frame and cup washers from Ground floor to 4th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 216 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 216 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair sinks made of stainless steel 1.00 mm thick sheet for kitchen or lab with plug, washers, waste pipe including bedding in cement mortar on to dwarf wall or including fixing cast iron cantilever brackets connecting union over all size 495mmx420mm bowl size from Ground floor to 4th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 219 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 219 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair 15mm bib tap (twin tap) with 2 way facility, cast copper alloy, screwed down, high pressure, chromium plated, fancy type , long body with CP cup from Ground floor to 4th storey complete all as specified and directed by Engr-in-Charge. Make:- Jaquar Cat No ORP 10037PM or equivalent as per list of makes as specified in CA.
All as per Item No 222 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 222 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix 40mm PVC pipes (LDPE) of pressure rating 6kgf/cm2 fixed complete to walls ceilings or in floor etc including all connectors and bends from Ground floor to 4th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 225 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 225 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix PVC connection 15 mm bore 45 cm long with brass coupling for CPVC pipess from Ground floor to 4th storey complete all as specified and directed by Engr-in-Charge. Make :-Prayag or equivalent as per list of makes mentioned in CA.
All as per Item No 228 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 228 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix PVC connection 15 mm bore 45 cm long with brass coupling for hot water from Ground floor to 4th storey complete all as specified and directed by Engr-in-Charge. Make :-Prayag or equivalent as per list of makes mentioned in CA.
All as per Item No 231 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 231 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair 75 mm dia stainless steel floor trap with grating including joint to waste pipe fixed in cement concrete type B-1(1:2:4) from Ground floor to 4th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 234 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 234 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Material and Labour for half brick thick wall with sub class 'B' bricks straight or curved on plan any radius built in cement mortar 1:4 from ground floor to IV th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 237 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 237 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Material and labour for RCC type B-1 1:2:4 (using 20mm graded stone aggregate) cover slab set in cement mortar 1:4 for fixing oval WHB including form works (reinforcement shall measured and paid separately)from ground floor to fourth storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 240 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 240 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Material and labour for TMT bars 6 to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips from ground floor to fourth storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 243 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 243 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix in repairs vitreous china wash basin white oval shape size approx 630x450mm excluding taps, waste, chained plug and porcelain stopper fixed on slab from ground floor to fourth storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 246 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 246 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Material and Labour for Rendering 10mm thick on fair faces of brick work or concrete surfaces in CM 1:4 finished even and smooth without using extra cement in Ground floor to 4th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 249 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 249 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply only pillar tap FOR COUNTER TOP WHB ,screwed down high pressure of pipe 15 mm from ground floor to fourth floor complete all as specified and directed by Engr-in-Charge. Make :- CERA or equivalent approved make as listed in CA
All as per Item No 252 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 252 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix Soap dish rectangular Stainless Steel for ground floor to fourth floor complete all as specified and directed by Engr-in-Charge.Make:_ Jaquar Cat No A CN-1131N or equivalent approved make as per list in CA. .
All as per Item No 255 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 255 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix 75 mm dia PVC (SWR) floor trap plain with steel grating including jointing with solvent cement from ground floor to fourth floor complete all as specified and directed by Engr-in-Charge.
All as per Item No 258 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 258 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix in repairs Stainless steel towel ring for ground floor to fourth storey complete all as specified and directed by Engr-in-Charge.Make :-Jaquar Cat No .- A CN -1121BN or equivalent as per list of makes mentioned in CA.
All as per Item No 261 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 261 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix 32mm PVC pipes (LDPE) of pressure rating 6kgf/cm2 fixed complete to walls ceilings or in floor etc including all connectors and bends for ground floor to fourth storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 264 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 264 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix 20 mm bore 3- layer PP-R Polypropylene random copolymer) pipes SDR 7.4 & SDR 11 UV stablised and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls ,ceiling or in floors or concealed etc and making good the disturbed surface including taking down old pipes from ground floor to fourth storey complete all as specified and as directed by the Engineer-in-Charge.
All as per Item No 267 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 267 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix in repairs 20 mm PP-R gate valves (brass insert) as per requirement of the site from ground floor to fourth storey complete all as specified and as directed by the Engineer-in-Charge.
All as per Item No 270 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 270 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix in repairs health faucet with cromium plated metalic flexible tube 1.5mtr, wall hook and CP Brass hand (Heavy Type) from ground floor to fourth storey complete all as specified and as directed by the Engineer-in-Charge. Make :-Jaquar Cat No . ALD- CHR 565 or equivalent as per list of makes mentioned in CA.
All as per Item No 273 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 273 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix in repairs vitreous china wash down water closet (pedestral pattern) coloured coupled Hindware Cat No 20024 or equivalent Florence or equivalent approved make as listed in CA including flush tank from ground floor to fourth storey complete all as specified and as directed by the Engineer-in-Charge.
All as per Item No 276 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 276 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair Vitreous China, semi-pedestal pattern (Anglo-Indian Type) white (excluding fixing bolts, flushing cistern from ground floor to fourth storey complete all as specified and as directed by the Engineer-in-Charge.
All as per Item No 279 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 279 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix in repairs 10Ltr capacity PVC valveless, syphonic action type flushing cistern, low level, white with inlet, ball valve, float and handle including brackets and connections to pipes and fixing of chain and pull, or lever if any from ground floor to fourth storey complete all as specified and as directed by the Engineer-in-Charge.
All as per Item No 282 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 282 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix in repairs wall mixer make Jaguar FLR-CHR-5281N or equivalent approved make as listed in CA 3 in one shower fixing arrangements, cast copper alloy, screwed down, high pressure, chromium plated, fancy type , long body with CP cup from ground floor to fourth storey complete all as specified and as directed by the Engineer-in-Charge.
All as per Item No 285 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 285 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix in repairs 15mm bib tap fancy type chromium plated cast copper alloy with crutch or butter fly handle,screwed for iron pipe or for brass ferrule from ground floor to fourth storey complete all as specified and as directed by the Engineer-in-Charge.
All as per Item No 288 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 288 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair CP Toilet paper holder, make jaguar CAN-CHR-1155 N or equivalent approved make as listed in CA from ground floor to fourth storey complete all as specified and as directed by the Engineer-in-Charge.
All as per Item No 291 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 291 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair CP Plate shower Make Jaguar or equivalent approved make as listed in CA from ground floor to fourth storey complete all as specified and as directed by the Engineer-in-Charge.
All as per Item No 294 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 294 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair Shower Arm 15 mm size , make Jaguar or equivalent approved make as listed in CA matching to Item 291 above from ground floor to fourth storey complete all as specified and as directed by the Engineer-in-Charge.
All as per Item No 297 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 297 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair PVC Framed looking mirror of size 12"X18" along with soap tray/Comb tray(Acrylic Type) from ground floor to fourth storey complete all as specified and as directed by the Engineer-in-Charge.
All as per Item No 300 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 300 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair Stop/angle valve of 15 mm bore,cast copper alloy,screwed down,high pressure, fancy type chromium plated from ground floor to fourth storey complete all as specified and as directed by the Engineer-in-Charge.
All as per Item No 303 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 303 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair Corner glass shelf of 8mm thick of size 300mmx120mm plain sheet glass and with brass, chromium plated bracket from ground floor to fourth storey complete all as specified and as directed by the Engineer-in-Charge. Make: Jaquar Cat NO ACN- 1173 or equivalent as per list of makes as specified in CA.
All as per Item No 306 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 306 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair PVC bathroom cabinet (white) of size 420 x 300 x 100mm (approx), with one single shutter and built in mirror in front of shutter from ground floor to fourth storey complete all as specified and as directed by the Engineer-in-Charge.
All as per Item No 309 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 309 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair Brass chromium plated tubular towel rail, 20mm dia, 'D' type 60 cm long between flanges from ground floor to fourth storey complete all as specified and as directed by the Engineer-in-Charge.
All as per Item No 312 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 312 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix 32mm waste coupling brass chomium plated for glazed ware sinks,basins etc with long screwed shanks and fly nuts flange and beded in red lead cement and other end fixed from Ground floor to 4th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 315 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 315 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix Telescopic hand shower with valve arrangements of cromium plated metalic flexible tube 2mtr, wall hook and CP Brass hand complete (Heavy Type) from Ground floor to 4th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 318 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 318 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Dismantling structural steel work any description not otherwise provided ,for hand rails/ballusters/window shutters/ frames from Ground floor to 4th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 321 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 321 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix 32mm dia stainles steel 316 grade hand rails including posts and struts from Ground floor to 4th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 324 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 324 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Material and labour for 100mm thick PCC plinth protection type C-2 1:3:6 (using 40mm graded stone aggregate)complete all as specified and directed by Engr-in-Charge.
Dismantling of Cast iron or PVC, soil waste and vent up to 100 mm dia and in any length with fittings and with any type of joints from Ground floor to 4th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 328 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 328 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix 110 mm PVC (SWR) pipes in any length with rubber ring joints fixed to walls from Ground floor to 4th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 331 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 331 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix 75 mm PVC (SWR) pipes in any length with rubber ring joints fixed to walls from Ground floor to 4th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 334 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 334 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix PVC (SWR) bends of any radius bore 110 mm with access door from Ground floor to 4th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 337 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 337 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix PVC (SWR) bends of any radius bore 75 mm with access door from Ground floor to 4th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 340 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 340 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix PVC (SWR) branch piece single (single 'Y') equal or un equal bore 110mm, with access door from Ground floor to 4th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 343 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 343 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix PVC (SWR) branch piece single (single 'Y') equal or un equal bore 75mm, with access door from Ground floor to 4th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 346 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 346 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix PVC (SWR) bends of any radius bore 110 mm from Ground floor to 4th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 349 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 349 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix PVC (SWR) bends of any radius bore 75mm from Ground floor to 4th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 352 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 352 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix PVC (SWR) junction single (single 'T") equal or unequal with access door bore of pipe 110 mm from Ground floor to 4th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 355 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 355 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix PVC (SWR) junction single (single 'T") equal or unequal with access door bore of pipe 75mm from Ground floor to 4th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 358 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 358 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix PVC (SWR) reducers bore 110 mm from Ground floor to 4th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 361 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 361 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Supply and fix PVC (SWR) Vent cowl 110mm in any storey complete all as specified and directed by Engr-in-Charge.
Supply and fix PVC (SWR) Vent cowl 75mm in any storey complete all as specified and directed by Engr-in-Charge.
Taking up or down steel tubing 20 mm dia and connections,including cleaning for refixing or removal to store from ground floor to fourth storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 366 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 366 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Supplying & fixing to walls/chases/ceilings or laying in floors CPVC pipes 32mm dia including all fittings (such as elbows, tees, reducers couplers, short pieces,connectors, etc.) and hooks (in case of concealed pipe work)/ clamps (in case of exposed pipe work from ground floor to fourth storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 369 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 369 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Supplying & fixing to walls/chases/ceilings or laying in floors CPVC pipes 20mm dia including all fittings (such as elbows, tees, reducers couplers, short pieces,connectors, etc.) and hooks (in case of concealed pipe work)/ clamps (in case of exposed pipe work from ground floor to fourth storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 372 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 372 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Supplying & fixing to walls/chases/ceilings or laying in floors CPVC pipes 15mm dia including all fittings (such as elbows, tees, reducers couplers, short pieces,connectors, etc.) and hooks (in case of concealed pipe work)/ clamps (in case of exposed pipe work from ground floor to fourth storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 375 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 375 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Taking down existing external wall treatment complete by scrapping down and washing with water and filling the cracks properly and making good the damaged plastered surfaces/RCC chajjas/roof projection with cement mortar/PCC and applying two coats of weather proof(Apex ultima protek or equivalent) over one coat of primer over one coat of sealent base coat upto 4th storey complete all as specified and directed by Engr-In-Charge.Note:- Application of primer,sealent coat and weather proof paint will be as per manufactures instruction. Anti fungal paint shall be got applied through authorized applicator only..
All as per Item No 378 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 378 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Material and labour for preparation of old ceiling surface and applying two coats of Oil bound distemper up to fourth Storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 381 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 381 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Taking down existing internal wall treatment complete by scrapping down and washing with water and filling the cracks properly and applying two coats of oil bound distemper over and including 3mm thick putty and one coat of acrylic primer upto 4th storey complete all as specified and directed by Engr-In-Charge.
All as per Item No 384 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 384 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Material and labour for Providing and injecting chemical emulsion for post constructional antitermite treatment along external wall / apron using chemical emulsion at the rate of 2.25 litres per linear metre of the vertical surface of the sub structure to a depth of 300mm including excavating channel along the wall and rodding etc in ground floor complete all as specified and as directed by Engineer-In-Charge.
Material and labour for Providing and injecting chemical emulsion for post constructional antitermite treatment at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same from ground floor to fourth floor complete all as specified and as directed by Engineer-In-Charge.
All as per Item No 388 herein before but for 5th to 8th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 388 herein before but for 9th to 12th storey complete all as specified and directed by Engr-in-Charge.
Material and labour for Providing and injecting chemical emulsion for post constructional antitermite treatment at points of soil under exsisting floors using emulsion @ one ltr per hole 300 mm apart along the wall and floor junctioning incl drilling and plugging 12mm dia holes with cement mortar (1 part cement 2 part coarse sand) to match the exsisting floor complete all as specified and as directed by Engineer-In-Charge.
Supply and fix 0.50 mm thick galvalume plain sheets as in gutters fixed to purlins or RCC parapets etc including side laps, by using 'J' bolts, nuts and washers etc all as per manufacturers instruction complete all as specified and directed by Engr-in-Charge.
Material and labour for Rehabilitation for minor cracks in 5 stages.(i) Removing cover concrete portion in the structural elements carefully with mechanical arrangements and hand chiseling, clean the loose dust and clean the reinforcement (ii) Applying anticorrosive coating Nitrozinc primer manufactured by M/s Fosroc Chemicals or equivalent, including providing sacrificial Zinc anode Galvashield XPI before application.(iii) Applying epoxy based bond coat Nitrobond EP manufactured by M/s Fosroc or equivalent as per manufactures instruction (iv) Preparation of Polymer modified mortar by mixing 3 ltrs of Nitrobond SBR manufactured by M/s Fosroc chemicals or equivalent as per manufactures instruction per bag of cement in cement and sand mortar 1:3 and rendering with trowel .(v) Membrane curing by 'Concure' manufactured by M/s Fosroc chemicals or equivalent up to 4th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 393 herein before but for V th storey and above up to VIII th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 393 herein before but IX th storey and above up to XII th storey complete all as specified and directed by Engr-in-Charge.
Microconccreting in RCC coloumns and Beams including chemicals, reinforcement ,form work average thickness not exceeding 100 mm as per the following stages (i) Support the slab and beam which is contributing the load for the coloumn under rehabilation. (ii) Remove the damaged concrete portions completely till the reiforcement is exposed from the member carefully with mechanical arrangements and hand chiseling and clean the dust particles. (ii) Anchoring shear connectors in the form of 'L' shaped bars of 10 mm dia HSD in to the existing concrete by drilling holes not less than 75 mm depth 12 mm dia in staggered position along the perimeter and height of member. Spacing shoud not be less than 300 mm for all sides. Before anchoring clean the holes with Jet compressed air to remove dust particles and anchor the dowel bars serve as shear connectors with chemical resin capsules manufactured by M/S Fosroc chemicals or equivalent. (iii) Clean the reinforcement and apply Nitrozinc primer manufactured by M/S Fosroc chemicals or equivalent with providing sacrificial Zinc anode Galvashield XPI (iv) Providing leakproof shuttering system for the jacket portion of the members and micro concrete with Rendroc RG manufactured by M/S Fosroc chemicals or equivalent( compressive strength of Micro concrete should be 45 MPa at 28 days) upto 4th storey complete all as specified and directed by Engr-in-Charge. Note:- Reinforcement will be measured and paid in connected item separately
All as per Item No 396 herein before but for V th storey and above up to VIII th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 396 herein before but IX th storey and above up to XII th storey complete all as specified and directed by Engr-in-Charge.
Material and Labour for Treating Horizontal expansion joints by (i) Clean the joint and remove the pad such that the depth should not be less half the width of joint including rectify the broken portion with polymer modified mortar or Micro concrete as required. (ii) Provide packer rod and affix masking tape either side of the joint including apply the primer to both side of joint and fix debonding tape. (iii) Mix the base and hardener of PU sealent Colper 200 and pour the same to the primed joint (iv) After setting provide Aluminium sheet of width 100 mm in such away that one side is fixed and other end free. Refill the area with required brick jelly taking the joint up to top compelete from ground floor to 4th storey all as specified and directed by Engr-in-Charge.
All as per Item No 399 herein before but for V th storey and above up to VIII th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 399 herein before but IX th storey and above up to XII th storey complete all as specified and directed by Engr-in-Charge.
Material and Labour for Treating Vertical expansion joints by (i) Clean the joint and remove the pad such that the depth should not be less half the width of joint including rectify the broken portion with polymer modified mortar or Micro concrete as required. (ii) Provide packer rod and affix masking tape either side of the joint including apply the primer to both side of joint and fix debonding tape. (iii) Mix the base and hardener of Poly sulphide sealent Tuffseal 2G and place the same to the primed joint (iv) After setting provide Aluminium sheet of width 100 mm in such away that one side is fixed and other end free. Refill the area with required brick jelly taking the joint up to top complete from ground floor to 4th storey all as specified and directed by Engr-in-Charge.
All as per Item No 402 herein before but for V th storey and above up to VIII th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 402 herein before but IX th storey and above up to XII th storey complete all as specified and directed by Engr-in-Charge.
Material and Labour for repair of cracks in the masonry walls (i) By marking 75 mm either side of the crack and cutting with hand held cutter including chip off the plaster and exposing brick work (ii) Make groove at every 150 mm c/c perpendicular to the crack and provide 8 mm dia TMT bar (iii) Prepare AR mortar in the ratio of 1:3 and add Nitobound AR manufactured by M/s Fosroc or equivalent per bag of cement and grout the same with 20 mm nozzle to the primed concrete surface . Fill up and finish the crack using a trowel complete upto 4th storey all as specified and directed by Engr-in-Charge. Note:-Reinforcement will be measured and paid in connected item separately.
All as per Item No 405 herein before but for V th storey and above up to VIII th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 405 herein before but IX th storey and above up to XII th storey complete all as specified and directed by Engr-in-Charge.
Material and Labour for repair of cracks between the interface of concrete and brick (i) By marking 75 mm either side of the crack and cutting with hand held cutter including chip off the plaster and exposing brick work and concrete surface (ii) Clean with water and allow to dry (iii) Prepare AR mortar in the ratio of 1:3 and add Nitobound AR manufactured by M/s Fosroc or equivalent per bag of cement and apply the same up to half the thickness of plaster using trowel to the primed concrete surface (iv)Fix chicken wire mesh or fibre mesh over the first layer of plastering. (v) Continue the 2nd layer of plastering with Nitobond SBR followed by smooth finish . Fill up and finish the crack using a trowel complete upto 4th storey all as specified and directed by Engr-in-Charge.
All as per Item No 408 herein before but for V th storey and above up to VIII th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 408 herein before but IX th storey and above up to XII th storey complete all as specified and directed by Engr-in-Charge.
Material and labour for Chequered stone finish exterior coloured heavy duty tiles of 300mmx300mmx9-10mm thick as in floor finishes etc jointed and pointed in neat cement slurry over and including 20mm thick screed bed in CM 1:6 complete all as specified and directed by Engr-in-Charge.
Material and labour for Mat finish ceramic tiles, light shade 10mm thick(square/rectangular)each tile exc 0.42Sqm but not exc 1Sqm in floors set jointed in neat cement slurry and pointed in white or coloured cement to match complete from ground floor to fourth storey all as specified and directed by Engr-in-Charge.
All as per Item No 412 herein before but for V th storey and above up to VIII th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 412 herein before but IX th storey and above up to XII th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 412 herein before but on skirting from ground floor to IV th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 415 herein before but for V th storey and above up to VIII th storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 415 herein before but IX th storey and above up to XII th storey complete all as specified and directed by Engr-in-Charge.
Taking down existing water proofing treatment of any description(Brick tile, concrete,roof kerb, rounded or chamfered on edges etc)and removal rubbish off the premises to out side of defence land complete all as specified and directed by Engr-in-Charge.
Material and labour for water proofing treatment with cement mortar 1:4 admixed with Nitobond SBR or equivalent@1 litre per 50Kg bag of cement. Down take rain water pipe Annuar space packing using Conbextra GP2 or equivalent mixed water and filling as per manufacturer,s specifications. water ponding for minimum for 48 hours and injection grouting of construction joints, leaking spot and honey combs with cementatious pressure grouting with 40 psi pump using Cebex 100 or equivalent@225gms mixed to 50Kg bag of cement including joints packing using polymer modified mortar. Providing and applying water proof coating using Fosroc Nitoproof 600 or equivalent, over dry surfaces and 1.5mm thick with 2 coats with interval period of 6 hours over substrata at a coverage rate of 2Kg/Sqm using spray/Squeegee/roller/brush.Water proofing coating shall have the elongation of 500-700%(ASTM D412-90), tear resistance of 21KN/m(ASTM D624-00)and tensile strength of > 1.9N/nSqm(ASTM D412-90) Termination to be done on wall extending the coating to min 300mm height above the finalised floor level as per vendor recommendation. Laying 200gsm non woven geo textile membrane over Nitoproof 600 coating with overlap sealed before providing screed concrete.complete all as specified and as directed by rhe Engineer-in-Charge.[Ref Ser No 5(b)ii of Zonal specification 2020]
Material and labour for Durastone tile of 300x300x10mm thick laid over and including screed bed in CM 1:4 15mm thick set and jointed in neat cement slurry and pointed with white or coloured cement to match with tie complete all as specified and directed by Engr-in-Charge.
Cutting out cracks to V-section in existing roofs or terracing, cleaning out , wetting, grouting with cement and sand slurry 1:3 using water proofing compound complete all as specified and directed by Engr-in-Charge.
Material and labour for Plain Cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in roof kerb rounded or chamfered on edges complete all as specified and directed by Engr-in-Charge.
Material and labour for Plain Cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in filling mass concrete, roof slab padding preparatory to roof treatment complete all as specified and directed by Engr-in-Charge.
Provision of labour and transportation for shifting of existing furniture(issued by MES) from the Viswanathan bldg(40DUs) and depositing to BSO furnitur yard at Kataribagh and shifting back the furniture to the DU after completion of all repair work. Note :- (i)Before shifting of Items/before commencement of work in each wing BSO(MES) will prepare an inventory of the furniture available in each quarter and same shall be verified while depositing items to BSO Yard.(ii) The quoted rate shall be inclusive of all labour required for shifting of furniture(from each DU of high rise bldg)and transportation arrangement including fuel.(iii) The furniture shall be deposited in existing condition carefully without any damage, If any damages caused, the same shall got rectified at the risk and cost of contractor.(iv) The list of furniture for one DU is enclosed as Annexure 1 for guidance.
ROAD/PATH/HARDSTANDING:- Surface dressing not exc 15cm deep in soft/loose soil complete all as specified and directed by Engr-in-Charge.
Material and labour for Hard core of gauge 63mm deposited, spread and levelled in layers n.exc 15cm thick watered and rammed to a true surface complete all as specified and directed by Engr-in-Charge.
Material and labour for Plain cement concrete 1:4:8 type D2 using 40mm graded stone aggregate 75mm thick as in floors to receive top layer complete all as specified and directed by Engr-in-Charge.
Material and labour for Coarse aggregate nominal size 6.3mm and below as in paving under floor spreading and levelling in layers not exc 25mm thick and well ramming including watering as required complete all as specified and directed by Engr-in-Charge.
Material and labour for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade with using grey cement and pigments complete all as specified and directed by Engr-in-Charge.
Material and labour for Plain cement concrete 1:2:4 type B1 using 20mm graded stone aggregate in kerbs and similar items including necessary form work complete all as specified and directed by Engr-in-Charge.
INTERNAL ELECTRIFICATION:-Taking down copper/Aluminium point wiring(light, fan, socket or power)complete including fixtures and fittings such as switches, ceiling rose, pendent, regulator sockets, light fittings etc removing materials to store for keeping in safe custody or for taking credit and making good the disturbed surfaces on wall/floors etc upto IV th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 431 here-in-before but V th storey and above up to VIII th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 431 here-in-before but IX th storey and above up to XII th storey complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Point wiring with 1.5Sqmm PVC insulated unsheathed with proper colour coding FRLSH multistranded single core copper conductor cable, 1100Volts grade in PVC concealed rigid conduit non metalic medium grade of size not less than 20mm dia with accessories concealed in wall/roof except beam, column and RCC roof including cutting chases including making good wall surfaces with existing surface and 1.6mm thick MS sheet pressed terminal box(recessed) with 3mm thick PVC laminated sheet top cover for accomodating switches socket regulators etc including 1.5Sqmm PVC insulated copper conductor as earth continuity wire for One light point controlled by one switch of 6 Amps SP One switch upto IV th storey complete all as specified and directed by Engineer-in-Charge.
All as per Item No 434 here-in-before but V th storey and above up to VIII th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 434 here-in-before but IX th storey and above up to XII th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 434 herein before but One ceiling fan point/exhuast fan controlled by one switch and Regulator upto IV th storey complete all as specified and directed by Engineer-in-Charge.
All as per Item No 437 here-in-before but V th storey and above up to VIII th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 437 here-in-before but IX th storey and above up to XII th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 434 herein before but One bell point controlled by one bell push switch upto IV th storey complete all as specified and directed by Engineer-in-Charge.
All as per Item No 440 here-in-before but V th storey and above up to VIII th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 440 here-in-before but IX th storey and above up to XII th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 434 herein before but One 3 pin 5 Amp switch sockets out let point on Same board upto IV th storey complete all as specified and directed by Engineer-in-Charge.
All as per Item No 443 here-in-before but V th storey and above up to VIII th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 443 here-in-before but IX th storey and above up to XII th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 434 herein before but One 3 pin 5 Amp switch sockets out let point on independent board upto IV th storey complete all as specified and directed by Engineer-in-Charge.
All as per Item No 446 here-in-before but Vth storey and above up to VIII th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 446 here-in-before but IX th storey and above up to XII th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 434 here-in-before but one light point controlled by two 2 way switches upto IV th storey complete all as specified and directed by Engineer-in-Charge.
All as per Item No 449 here-in-before but V th storey and above up to VIII th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 449 here-in-before but IX th storey and above up to XII th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 434 herein before but with 2.5Sqmm copper conductor including 2.5Sqmm copper cable on earth wire for one 6 pin 16Amps socket outlet on Independent board [for Geyser] upto Fourth storey all as specified and as directed by Engineer-in-Charge.
All as per Item No 452 here-in-before but V th storey and above up to VIII th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 452 here-in-before but IX th storey and above up to XII th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 434 herein before but with 4Sqmm FRLS copper conductor including 4Sqmm FRLS copper cable on earth wire for one 15Amps switch socket outlet on Independent board [for A/C] up to IV th Storey all as specified and as directed by Engineer-in-Charge.
All as per Item No 455 here-in-before but V th storey and above up to VIII th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 455 here-in-before but IX th storey and above up to XII th storey complete all as specified and as directed by Engineer-in-Charge.
Supply and fix Switch 6A one way SP modular type single pole one way 5Amps upto IV th Storey all as specified and directed by Engineer-in-Charge.
All as per Item No 458 here-in-before but V th storey and above up to VIII th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 458 here-in-before but IX th storey and above up to XII th storey complete all as specified and as directed by Engineer-in-Charge.
Supply and fix Ceiling rose PVC/Polycarbonate , surface type 65mm x 50mm three terminals upto IV th Storey all as specified and as directed by Engineer-in-Charge.
All as per Item No 461 here-in-before but V th storey and above up to VIII th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 461 here-in-before but IX th storey and above up to XII th storey complete all as specified and as directed by Engineer-in-Charge.
Supply and fix Switch 16Amps one way SP modular type upto IV th Storey all as specified and as directed by Engineer-in-Charge.
All as per Item No 464 here-in-before but V th storey and above up to VIII th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 464 here-in-before but IX th storey and above up to XII th storey complete all as specified and as directed by Engineer-in-Charge.
Supply and fix Modular bell push flush type single pole 5Amps upto IV th Storey all as specified and as directed by Engineer-in-Charge.
All as per Item No 467 here-in-before but V th storey and above up to VIII th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 467 here-in-before but IX th storey and above up to XII th storey complete all as specified and as directed by Engineer-in-Charge.
Supply and fix Call bell AC 230V single pole upto IV th Storey all as specified and as directed by Engineer-in-Charge.
All as per Item No 470 here-in-before but Vth storey and above up to VIII th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 470 here-in-before but IX th storey and above up to XII th storey complete all as specified and as directed by Engineer-in-Charge.
Supply and fix Switch modular type 6Amps single pole 2 way upto IV th Storey all as specified and as directed by Engineer-in-Charge.
All as per Item No 473 here-in-before but V th storey and above up to VIII th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 473 here-in-before but IX th storey and above up to XII th storey complete all as specified and as directed by Engineer-in-Charge.
Supply and fix Modular socket shuttered 6Amps, 5 pin combined 2 module controlled by one switch upto IV th Storey all as specified and as directed by Engineer-in-Charge.
All as per Item No 476 here-in-before but V th storey and above up to VIII th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 476 here-in-before but IX th storey and above up to XII th storey complete all as specified and as directed by Engineer-in-Charge.
Supply and fix Modular socket shuttered 6/16Amps, 6 pin combined 3 module controlled by one switch upto IV th Storey all as specified and as directed by Engineer-in-Charge.
All as per Item No 479 here-in-before but V th storey and above up to VIII th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 479 here-in-before but IX th storey and above up to XII th storey complete all as specified and as directed by Engineer-in-Charge.
Supply and fix Power unit 20Amps modular type for geyser all as specified and as directed by Engineer-in-Charge.Make:- Havells Cat Part No AHOO002004 or equivalent as specified in list manufactueres in CA.
Supply and fix Power unit 25Amps modular type for AC all as specified and as directed by Engineer-in-Charge.Make:- Havells Cat Part No AHOO002504 or equivalent as specified in list manufactueres in CA.
Supply and fix Electronic stepped type modular fan regulator AC SP 5 steps 2 module upto IV th Storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 484 here-in-before but V th storey and above up to VIII th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 484 here-in-before but IX th storey and above up to XII th storey complete all as specified and as directed by Engineer-in-Charge.
Supply and fix Angle Lamp holder PVC suitable for fixing of LED bulbs of any wattage 230volts SP upto IV th Storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 487 here-in-before but V th storey and above up to VIII th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 487 here-in-before but IX th storey and above up to XII th storey complete all as specified and as directed by Engineer-in-Charge.
Supply and fix Regal batten for LED tube lights both side connection type and LED tube rod 1 X20 watt both side connection all as specified and as directed by Engineer-in-Charge. Make of Batten:- Havells Cat Part No Regal batten 8UPT001x22WSSBSWH/Crompton Cat Part No. IGP131LT8-16/Philips Cat Part No TMC501P1XTLED22WP3241. Make of tube rod: Havells Cat Part No. Crystal 1213T8DSTL20W LED 865 GLASS/ Crompton Cat Part No. LG-T8-20-865-2/Philips Cat Part No. Essential LED tube 1200mm 20W865T865T8IND-1
Supply and fix LED Mini mirror light 1 x 10W/12W wall/surface mounted luminaries with engineering plastic housing wired with all accessories including provn of flexible copper wire from ceiling rose to light fitting terminal complete all as specified and as directed by Engineer-in-Charge. Make:- Crompton Cat Part No.LDL-10WW/Lukar Cat Part No LTSM10/Philips B No 21LED12S or equivalent make as listed in CA.
Supply and fix LED decorative wall light fixture made up of polycarbonate suitable for upto 15watt with LED bulb of 10watt including taking down the existing complete all as specified and as directed by Engineer-in-Charge. Make:- Havells City 3 LHDL06160099 or equivalent make as listed in CA.
Supply and fix 9Watt LED bulb with B22 base, clear acrylic diffuser, self declaring R No PF 90, 85 lumens light output all as specified and as directed by Engineer-in-Charge. Make:- Luker Cat Part No LBPC09CL or equivalent make as listed in CA.
Supply and fix Building security light made up of pressure die cast housing with toughened glass and high power LEDs with option of secondary optic with IP 66 protection of 72 watt including suitable GI bracket and fixing arrangements on walls complete all as specified and as directed by Engineer-in-Charge. Make:- Crompton Cat Part No LSTP-72-CDL-M or Jaquar Cat Part No. LPCRSRT45WWXW/Philips HSN code 94054090.
Supply and fix LED flood light made up of pressure die cast housing with toughened glass and high power LEDs with option of secondary optic with IP 66 protection, 3000K with 10KV SPD of 50watt complete all as specified and as directed by Engineer-in-Charge. Make:- Crompton Cat Part No LFL-50-CDL/60-M or Jaquar Cat Part No. LFLD02S050XW/Philips Cat Part No. BVP 161 LED 43NW/CW/WW 50W.
Supply and fix Single phase Electric meter 0 to 30A enclosure complete including taking down the existing and deposited to MES store yard all as specified and as directed by Engineer-in-Charge.. Make:-L &T WM101BC5DDH or equivalent as listed in CA.
Supply and fix Meter box made of 3mm thick sheet and locking arrangement to accommodate 4Nos of single phase energy meter with glass sheet for reading meter all as specified and as directed by Engineer-in-Charge.
Taking down ceiling fan, sealing cable end , dismantling blades and depositing to MES store yard upto IV th Storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 498 here-in-before but V th storey and above up to VIII th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 498 here-in-before but IX th storey and above up to XII th storey complete all as specified and as directed by Engineer-in-Charge.
Supply and fix Energy efficient ceiling fan 1200mm sweep(5 star rated)230volt 50Hz including all electrical connection complete all as specified and as directed by Engineer-in-Charge. Make:- Havells Cat part No ES-40 or Crompton Cat part No Maximus(5 star rated) /Philips/Usha or equivalent as listed in CA
Supply and fix Wall mounted fan 400mm sweep, 1440 RPM with fixing arrangements on wall including screws, rawal plugs etc connecting to the electrical system complete all as specified and as directed by Engineer-in-Charge. Make:- Havells Cat part No Girik or V Guard/Almonard or equivalent as listed in CA
Dismantling and taking down the existing Exhaust fan of any type, any make and depositing to MES store yard complete all as specified and directed by Engr-in-Charge.
Supply and fix Exhaust fan 300mm sweep metal body heavy duty, single phase 230volt including taking down the existing and deposited in MES store yard complete all as specified and as directed by Engineer-in-Charge. Make:- Havells Cat part No Ventil Air-DX White or Crompton Cat part No EXHD300-4-1 or Bajaj or equivalent as listed in CA
All as per Item No 504 here-in-before but PVC body exhaust fan 230mm sweep. Make :- Havells Model: Ventil Air-DX White or equivalent as listed in CA
Dismantling and removing the existing Geysers of any type, any make and depositing to MES store yard complete all as specified and directed by Engr-in-Charge.
Supply , Install and testing of storage water heater of 25 Ltrs capacity, rust proof outer cover, PUF insulation to reduce the heatloss, inner tank made of 304 L grade stainless steel withstand pressure up to 6.5Kg/Sqcm ACC protection for inner tank, 5 star BEE rated, adjustable thermostat all safety systems etc as specified and directed by Engr-in-Charge. Make:- V-Guard Model SPRING HOT PLUS/Bajaj Model NEW SHAKTI/Jaquar Model ELENA PRIME VERTICAL/USHA.
Material and labour for Earthing complete with galvanised steel earth plate electrode size 600x600 x6.00mm thick burried directly in ground vertically in pit of depth not less than 2.25 mtr below normal ground level with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by 15cm of thick and packed layers of charcoal and common salt and electrode connected to and including galvanised iron strip 25x3 mm [max length of 7.5mtrs]earth lead by means of bolts, nuts, check nuts and washers of galvanised steel and earth lead protected by GI protection pipe light grade 40mm bore with all fittings from upper edge of earth plate to body of equipments fixed with and including 25x4mmFI clamps and also including provision of GI pipe light grade 20mm bore for watering, funnel with wire mesh. PCC chamber pit in PCC 1:3:6 type C-1, 40 mm thick precast RCC M-25 (design mix)cover reinforced with 8 mm dia TMT bars @ 10 cm C/C on both sides and handle, excavation and earth work in any type of soil and removal upto 50 m complete all as specified and shown in electric plate No.3 of SSR Part-I(2009), connecting to earthing test point all as specified & as directed including testing on completion.
Material and labour for Submain wiring in PVC conduit concealed in wall with 4 Sqmm two single core using multistranded copper conductor FRLS insulated unsheathed with and incl one run of 4Sqmm insulated unsheathed FRLS insulated multistranderd copper conductor as earth continuity conductor connected to common earth dolly drawn in PVC conduit medium grade ISI marked with accessories upto IV th Storey complete all as specified and as directed by the Engineer-in-Charge. (Note:2 runs of 4Sqmm , one run of 4Sqmm and one run of PVC conduit shall be measured as one run only
All as per Item No 509 here-in-before but V th storey and above up to VIII th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 509 here-in-before but IX th storey and above up to XII th storey complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Submain wiring in PVC conduit concealed in wall with 10 Sqmm two single core using multistranded copper conductor FRLS insulated unsheathed with and incl one run of 10Sqmm insulated unsheathed FRLS insulated multistranderd copper conductor as earth continuity conductor connected to common earth dolly drawn in PVC conduit medium grade ISI marked with accessories upto IV th Storey complete all as specified and as directed by the Engineer-in-Charge. (Note:2 runs of 10Sqmm , one run of 10Sqmm and one run of PVC conduit shall be measured as one run only
All as per Item No 512 here-in-before but V th storey and above up to VIII th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 512 here-in-before but IX th storey and above up to XII th storey complete all as specified and as directed by Engineer-in-Charge.
Supply and fix to walls/ceiling and testing XLPE insulated , Screened PVC bedded, Galvanized steel strip or wire armoured , Electric power cables(heavy duty) 1100 volts grade AC with stranded Aluminium conductor of size 25Sqmm 4core upto IV th Storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 515 here-in-before but V th storey and above up to VIII th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 515 here-in-before but IX th storey and above up to XII th storey complete all as specified and as directed by Engineer-in-Charge.
Supply and fix to walls/ceiling and testing XLPE insulated , Screened PVC bedded, Galvanized steel strip or wire armoured , Electric power cables(heavy duty) 1100 volts grade AC with stranded Aluminium conductor of size 35Sqmm 3.5core upto IV th Storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 518 here-in-before but V th storey and above up to VIII th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 518 here-in-before but IX th storey and above up to XII th storey complete all as specified and as directed by Engineer-in-Charge.
Supply and fix Sheet metal enclosure for MCB DB SPN 4 ways double door upto IV th Storey all as specified and directed by Engineer-in-Charge.Make:- Legrand Cat Part No 5076 10 or equivalent as per list of make in CA
All as per Item No 521 here-in-before but V th storey and above up to VIII th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 521 here-in-before but IX th storey and above up to XII th storey complete all as specified and as directed by Engineer-in-Charge.
Supply and fix Sheet metal enclosure for MCB DB SPN 16 ways double door upto IV th Storey all as specified and directed by Engineer-in-Charge..Make:- Legrand Cat Part No 5076 23 or equivalent as per list of make in CA
All as per Item No 524 here-in-before but Vth storey and above up to VIII th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 524 here-in-before but IX th storey and above up to XII th storey complete all as specified and as directed by Engineer-in-Charge.
Supply and fix Sheet metal enclosure VTPN up to 250Amps MCCB incomer for MCB DB 6 way IP 54 Metal door complete all as specified and directed by Engineer-in-Charge.
Supply and fix Sheet metal enclosure VTPN up to 250Amps MCCB incomer for MCB DB 4 way IP 54 Metal door complete all as specified and directed by Engineer-in-Charge..Make:- Legrand Cat Part No 5077 58 or equivalent as per list of make in CA
Supply and fix MCCB 63Amps 415 volt 4 pole 16KA rupturing capacity upto IV th Storey all as specified and directed by Engineer-in-Charge..Make:- Legrand Cat Part No 4200 13 or equivalent as per list of make in CA
Supply and fix MCCB 100 Amps 415 volt 4 pole 16KA rupturing capacity upto IV th Storey all as specified and directed by Engr-in-Charge..Make:- Legrand Cat Part No 4200 15 or equivalent as per list of make in CA
All as per Item No 530 here-in-before but V th storey and above up to VIII th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 530 here-in-before but IX th storey and above up to XII th storey complete all as specified and as directed by Engineer-in-Charge.
Supply and fix MCB SPN 40Amps 240 volt upto IV th Storey all as specified and directed by Engr-in-Charge..Make:- Legrand Cat Part No 4086 18 or equivalent as per list of make in CA
All as per Item No 533 here-in-before but V th storey and above up to VIII th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 533 here-in-before but IX th storey and above up to XII th storey complete all as specified and as directed by Engineer-in-Charge.
Supply and fix MCB SP 6 Amps to 32 Amps 240 volt upto IV th Storey all as specified and directed by Engr-in-Charge. .Make:- Legrand Cat Part No 4085 87 to 95 or equivalent as per list of make in CA
All as per Item No 536 here-in-before but V th storey and above up to VIII th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 536 here-in-before but IX th storey and above up to XII th storey complete all as specified and as directed by Engineer-in-Charge.
Supply and fix RCCB DP 30mA 40Amps upto IV th Storey all as specified and directed by Engr-in-Charge. .Make:- Legrand Cat Part No 4118 52 or equivalent as per list of make in CA
All as per Item No 539 here-in-before but V th storey and above up to VIII th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 539 here-in-before but IX th storey and above up to XII th storey complete all as specified and as directed by Engineer-in-Charge.
Taking down old sub main wiring of any size all as specified and directed by Engr-in-Charge.
Taking down old LT XLPE cable of any size all as specified and directed by Engr-in-Charge.
Taking down old unserviceable meter box of any size complete all as specified and directed by Engr-in-Charge.
Taking down old unserviceable DB main switch MCCB of any size complete all as specified and directed by Engr-in-Charge.
LIGHTENING PROTECTION:-Material and labour for Earthing complete with galvanised steel earth plate electrode size 600x600 x6.00 mm thick burried directly in ground vertically in pit of depth not less than 2.25 mtr below normal ground level with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanised iron strip 32X6 mm earth lead by means of bolts, nuts, check nuts and washers of galvanised steel and earth lead protected by GI protection pipe light grade 40mm bore with all fittings from upper edge of earth plate to body of equipments fixed with and including 25x4mmFI clamps and also including provision of GI pipe light grade 20mm bore for watering, funnel with wire mesh. PCC chamber pit in PCC 1:3:6 type C-1, 40 mm thick precast RCC M-25 (design mix)cover reinforced with 8 mm dia TMT bars @ 10 cm C/C on both sides and handle, excavation and earth work in any type of soil and removal upto 50 m complete all as specified and shown in electric plate No.3 of SSR Part-I(2009), connecting to earthing test point upto IV th Storey all as specified & as directed including testing on completion.
Material and labour for Galvanised iron strip 32 x 6mm saddles and fixing screws etc for roof conductors and down conductors above ground upto IV th Storey complete all as specified and directed by Engr-in-Charge.
Material and labour for Aluminium strip 25mmx3.15mm complete with saddles epoxy base and fixing screws for roof conductors and down conductors above gound upto IV th Storey complete all as specified and directed by Engr-in-Charge.
All as per Item No 548 here-in-before but V th storey and above up to VIII th storey complete all as specified and as directed by Engineer-in-Charge.
All as per Item No 548 here-in-before but IX th storey and above up to XII th storey complete all as specified and as directed by Engineer-in-Charge.
Supply and fix Air termination, single pointed Aluminium rod 12mm dia and 300mm long from IX th upto XII th Storey complete all as specified and directed by Engr-in-Charge.
Supply and fix Test point terminal block made of MS box size 75x75x25mm drilled and screwed including 3Nos. 8mm dia 25mm long hex. head screw and PVC junction box upto IV th Storey complete all as specified and directed by Engr-in-Charge.
FIRE FIGHTING:-Supply and lay and jointing Ductile iron pipe 150mm(6")dia with flanged ends centrifugally cast ,class K-9 in any length laid in trenches/ floors or fixed to walls including all jointing materials such as heavy duty rubber gasket ,GI bolts, GI nuts, GI washers etc complete all as specified and directed by Engr-in-Charge
All as per Item No 553 here-in-before but 100mm (4") complete all as specified and directed by Engr-in-Charge
Material and labour for DI fittings of flanged ends such as bends , tees, single branch, Y junctions, double branch, straight connecting pieces any type and angle/radius etc for flanged pipes up to 150mm bore complete all as specified and directed by Engr-in-Charge
Supply and fix MS pipe C class 200mm dia with welded joints duly painted with two coats of epoxy paint as per approved colour coding for fire fighting system over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge
Supply and fix MS pipe C class 150mm dia with welded joints duly painted with two coats of epoxy paint as per approved colour coding for fire fighting system over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge
Supply and fix MS pipe C class 100mm dia with welded joints duly painted with two coats of epoxy paint as per approved colour coding for fire fighting system over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge
Supply and fix MS pipe C class 80mm dia with welded joints duly painted with two coats of epoxy paint as per approved colour coding for fire fighting system over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge
Supply and fix MS pipe C class 25mm dia with welded joints duly painted with two coats of epoxy paint as per approved colour coding for fire fighting system over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge
Supply , fix and connect landing valve conforming to IS 5290 [Internal hydrant] single headed (Oblique type] Type 'A , Stainless steel, ISI marked, 63mm, female instantaneous outlet with Grey Cast Iron Hand Wheel, PVC blank cap and chain and having suitable flanges for 100mm dia wet riser including necessary heavy duty gasket, GI bolts, GI nuts, GI washers etc including taking down the existing complete all as specified and directed by Engr-in-Charge. Make:- Swastik/Minimax/SB or equivalent as listed in CA.
All as per Item No 561 here-in-before but double headed (External hydrant) all as specified and directed by Engr-in-Charge
Supply and fix Yard hydrant post/ stand post 80mm dia GI both end flanged type 1.5m Height duly painted with 2 coats of Signal Red Synthetic Enamel paint including necessary heavy duty gasket, GI bolts, GI nuts, GI washers etc complete all as specified and directed by Engr-in-Charge.
Supply and fix Flanged outlet 4 way inlet Breeching(fire brigade inlet connection suction collecting head) having Cast iron body consisting of four Nos 63mm dia instantaneous type Gun metal adaptors/Couplers with PVC blank cap and chain including necessary heavy duty gasket, GI bolts, GI nuts, GI washers etc including taking down old unserviceable complete all as specified and directed by Engr-in-Charge.
Supply and fix on wall using Anchoring bolts at suitable locations, fabricated hose cabinet made out of 18 guage MS sheet of size 800x600x250mm with double door with 4mm thick glass and door frame made of 16 guage MS sheet painted fire red out side and brilliant white inside with lock and duplicate keys suitable for indoor use including taking down old unserviceable complete all as specified and directed by Engr-in-Charge.
All as per Item No 565 herein before but for outdoor use, mounted on PCC type D2 1:4:8 using 40mm graded stone aggregate foundation 800x600x1000mm including necessary facia finish using cement mortar complete all as specified and directed by Engr-in-Charge.
Supply and fix Dura RRL Hose (Reinforced Rubber Lined Hose) with elastomeric coating conforming to IS 636/1988 Type 'A' ISI marked Circular Woven Jacket fire delivery hose 63mm dia treated against abrasion, Bacteria & Fungas Resistant having burst pressure of 35.70Kgf/Sqcm, 15M long with SS male and female coupling adaptor including taking down old unserviceable complete all as specified and directed by Engr-in-Charge
Supply and fix on wall using Anchoring bolts at suitable locations, fabricated First Aide Hose Reel Drum for fire fighting fixed/swinging wall mounted type ISI marked along with ISI marked Thermo Hybrid Compound hose pipe 10Kgf/Sqcm, 30M long, 20mm dia conforming to IS 12585 suitable for fire hose drum with 25mm threaded inlet and 20mm outlet including taking down old unserviceable complete all as specified and directed by Engr-in-Charge
Supply and fix SS branch pipe 63mm dia male instantaneous inlet, threaded outlet fitted with rotory operated SS shut off Long nozzle of 15mm bore ISI marked with shut spray and jet functions including taking down old unserviceable complete all as specified and directed by Engr-in-Charge
Supply and fix Hand operated butterfly valve 150mm dia of pressure rating not less than 15Kg/Sqcm flanged type including necessary heavy duty gasket, GI bolts, GI nuts, GI washers etc including taking down old unserviceable complete all as specified and directed by Engr-in-Charge
All as per Item No 570 here-in-before but 100mm dia all as specified and directed by Engr-in-Charge
All as per Item No 570 herein before but 80mm dia all as specified and directed by Engr-in-Charge
Supply and fix Dual plates CI wafer type Non Return/Check Butterfly valve 150mm dia tested to pressure rating 15Kg/Sqcm flanged type including necessary heavy duty gasket, GI bolts, GI nuts, GI washers etc including taking down old unserviceable complete all as specified and directed by Engr-in-Charge
All as per Item No 573 herein before but 100mm dia all as specified and directed by Engr-in-Charge
Supply and fix Cast copper alloy 25mm bore hand operated Ball valve duly threaded including taking down old unserviceable complete all as specified and directed by Engr-in-Charge
Supply and fix Pressure guage 100mm dia with ball valve(4") dia 0-21Kg/Sqcm pressure rating including taking down old unserviceable complete all as specified and directed by Engr-in-Charge
Supply and fix Pressure Switch 15mm dia all as specified and directed by Engr-in-Charge
Supply and fix Gun metal gate valve 25mm dia complete all as specified and directed by Engr-in-Charge
Supply and fix 25mm dia screw type non return valve complete all as specified and directed by Engr-in-Charge
Supply and fix Air cushioned vessel 250mm dia and 1.2M length complete all as specified and directed by Engr-in-Charge
Supply, install, connecting, testing and commissioning on PCC platform[rate inclusive of platform], Diesel Engine driven pump, CI casing and bronze impeller, 2280LPM, 70M head with fuel tank and all connected accessories as per manufactuerer direction including suitable capacity diesel tank with all connections as per manufacturers instructions complete all as specified and directed by Engr-in-Charge. .
Supply and fix Electrical driven Jockey pump 180LPM, 70meter head , 3 phase 415volts with all connected accessories complete all as specified and directed by Engr-in-Charge
Supply and fix Flange ended foot valve, ball type 150mm dia complete all as specified and directed by Engr-in-Charge.
Supply , Install, connecting, testing and commissioning on platform[rate inclusive of platform], fire -pump, electrically driven horizontal end roof suction, centrifugal type, 70meter head, 2280LPM having a minimum discharge pressure of 3.5Kg/Sqcm at roof with suitable MS channel base painted suitable for 440V, 3 phase, 50Hz conforming to IS-12469: 1988 with CI casing/body, Bronze impeller and SS shaft, bronze shaft sleeve mounted on heavy duty bearing suitable for continuous operation with range of operation 0% to 150% of rated capacity suitable for automatic operation with non over loading power characteristics for frequent start/stop operation including necessary heavy duty gasket, GI bolts, GI nuts, GI washers etc including taking down old U/S complete all as specified and directed by Engr-in-Charge.
Supply and fix Aviation light on top of the building including taking down old one complete complete all as specified and directed by Engr-in-Charge.
Supply and fix Flange ended foot valve, ball type 100mm dia complete all as specified and directed by Engr-in-Charge.
Supply , Erection, Testing and commissioning priming storage PVC tank 500 Litres, ISI marked including necessary heavy duty gasket, Leak proof paste etc including taking down the existing complete all as specified and directed by Engr-in-Charge.
Supply and fix CPVC pipe SDR 11 wall with all fittings 40mm outer dia including necessary leak proof CPVC paste including taking down the existing complete all as specified and directed by Engr-in-Charge.
All as per Item No 588 here-in-before but 32mm all as specified and directed by Engr-in-Charge.
Supply and fix CPVC ball valves 40mm including necessary Leak proof CPVC paste including taking down old unserviceable complete all as specified and directed by Engr-in-Charge.
All as per Item No 590 here-in-before but 32mm all as specified and directed by Engr-in-Charge.
Supply and fix GM NRV 40mm with GM adaptors duly threaded including taking down old unserviceable complete all as specified and directed by Engr-in-Charge.
Material and labour for Valve Chamber of size 900x900x900mm complete by PCC foundation in mass concrete 1:4:8 type D2, brick work in CM 1:6, PCC 1:2:4 type B1 for grouting, Plastering of wall internal surface only with CM 1:6 including chamber cover made out of Angle iron frame 50x50x6mm, Valve pit cover made out of MS sheet of 6mm thick and locking arrangement. Painting of valve pit and frame with two coats of synthetic enamel paint over a coat of red oxide primer incl necessary earth work complete all as specified and directed by Engr-in-Charge.
Excavation in trenches not exc 1.5m wide and not exc 1.5m depth for laying of UG cables, pipes etc and getting out in soft/loose soil complete all as specified and directed by Engr-in-Charge.
Excavation in trenches not exc 1.5m wide and not exc 1.5m depth for laying pipes etc and getting out in hard/PCC road/PCC platform floor/RCC road/road cutting complete all as specified and directed by Engr-in-Charge.
Returning filling in including spreading, levelling , watering and well ramming in to layers not exc 25cm thick in soil complete all as specified and directed by Engr-in-Charge.
Removing excavated soil to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed by Engr-in-Charge.
Material and labour for Earthing complete with galvanised steel earth plate electrode size 600x600 x6.00 mm thick burried directly in ground vertically in pit of depth not less than 2.25 mtr below normal ground level with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanised iron strip 32X6 mm earth lead by means of bolts, nuts, check nuts and washers of galvanised steel and earth lead protected by GI protection pipe light grade 40mm bore with all fittings from upper edge of earth plate to body of equipments fixed with and including 25x4mmFI clamps and also including provision of GI pipe light grade 20mm bore for watering, funnel with wire mesh. PCC chamber pit in PCC 1:3:6 type C-1, 40 mm thick precast RCC M-25 (design mix)cover reinforced with 8 mm dia TMT bars @ 10 cm C/C on both sides and handle, excavation and earth work in any type of soil and removal upto 50 m complete all as specified and shown in electric plate No.3 of SSR Part-I(2009), connecting to earthing test point all as specified & as directed including testing on completion.
Material and labour for Earth continuity conductor or main earthing lead 25x3mm aluminium strip fixed to wall on porcelain insulators complete all as specified and directed by Engr-in-Charge.
Material and labour for Plain cement concrete 1:2:4 type B1 using 20mm graded stone aggregate in foundations, road crossing , floor filling, pipe supports etc incl facia finish with cement mortar complete all as specified and directed by Engr-in-Charge.
Supply and fix on wall/roof/floor etc connect, testing XLPE insulated(Heavy duty)Armoured cable with stranded copper conductor 8 core 1.5 Sqmm complete all as specified and directed by Engr-in-Charge.
Supply and fix Single core copper cable multistranded unsheathed including steel conduit under floor from starter to pump set of 50 Sqmm [Star delta connection] complete all as specified and directed by Engr-in-Charge.
All as per Item No 604 here-in-before but 10 Sqmm cable all as specified and directed by Engr-in-Charge.
Taking down existing single head hydrant valve and depositing to MES store Yard all as specified and directed by Engr-in-Charge.
Taking down existing double door hose box and depositing to MES store Yard all as specified and directed by Engr-in-Charge.
Taking down existing fire fighting hose and depositing to MES store Yard all as specified and directed by Engr-in-Charge.
Taking down existing ball valve 20mm and depositing to MES store Yard all as specified and directed by Engr-in-Charge.
Taking down existing 90hp electrical pump and depositing to MES store Yard all as specified and directed by Engr-in-Charge.
Taking down existing 90hp diesel pump and depositing to MES store Yard all as specified and directed by Engr-in-Charge.
Taking down existing 25hp electrical pump and depositing to MES store Yard all as specified and directed by Engr-in-Charge.
Taking down existing 100mm sluice valve and removing to MES store Yard all as specified and directed by Engr-in-Charge.
Taking down existing 100mm bore NRV and removing to MES store Yard all as specified and directed by Engr-in-Charge.
Taking down existing 100mm foot valve and removing to MES store Yard all as specified and directed by Engr-in-Charge.
Taking down existing 80mm foot valve and removing to MES store Yard all as specified and directed by Engr-in-Charge.
Taking down existing Yard hydrant post 80mm dia and removing to MES store Yard all as specified and directed by Engr-in-Charge.
Taking down existing fire brigade inlet and removing to MES store Yard all as specified and directed by Engr-in-Charge.
Taking down existing 100mm dia MS pipe and removing to MES store Yard all as specified and directed by Engr-in-Charge.
Taking down existing 80mm dia MS pipe and removing to MES store Yard all as specified and directed by Engr-in-Charge.
Taking down existing 25mm dia MS pipe and removing to MES store Yard all as specified and directed by Engr-in-Charge.
Taking down existing pump control panel and removing to MES store Yard all as specified and directed by Engr-in-Charge.
Taking down existing copper cable of any type and size all as specified and directed by Engr-in-Charge.
Taking down existing electric operated pump and motor assembly complete with all connections and depositing to MES store yard all as specified and directed by Engr-in-Charge.
Taking down existing diesel driven pump set complete with all connections and depositing with store yard of MES all as specified and directed by Engr-in-Charge.
Taking down existing jockey pump set complete with all connections and depositing with store yard of MES all as specified and directed by Engr-in-Charge.
Kurian And Varghese
SHAIJAL T M
VIJAY CONSTRUCTIONS
Powertech Engineers
FUTURE ONE FACILITY MANAGEMENT
A2Z ENGINEERS AND PILE FOUNDATIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .