Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.7 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹19.9 L+₹1.2 L (6.37%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹21.2 L+₹2.5 L (13.3%)Rejected-Finance | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹22.3 L+₹3.6 L (19.2%)Rejected-Finance DOOR NO 2 31 23 SECTOR 7 SBI COLONY MVP VISAKHAPATNAM 530 017 | VISAKHAPATANAM | ANDHRA PRADESH | 530017 | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹22.4 L+₹3.6 L (19.4%)Rejected-Finance | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹30.4 L
EMD Value
₹60,800
Closing Date
22 Sept 2020, 6:00 pmClosed
GE I DM
Naval Dockyard Visakhapatnam 530014
REPAIR / MAINTENANCE OF LT CAPACITORS BANK AND ALLIED WORKS AT VARIOUS SUBSTATINS AT NAVAL DOCKYARD VISAKHAPATNAM
2020_MES_371821_1
SSGE/8301/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Naval Dockyard Visakhapatnam
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE I DM
₹60,800
Yes
3 May 2021
2 Sept 2020
29 Sept 2020
2 Sept 2020
22 Sept 2020
16 Sept 2020
Amount
Supply only LTXL capacitor power heavy duty 10 kVAr 415 volts 50 Hz
Supply only LTXL capacitor power heavy duty 20 kVAr 415 volts 50 Hz
Supply only LTXL capacitor power heavy duty 25 kVAr 415 volts 50 Hz
Supply only LTXL capacitor power heavy duty 40 kVAr 415 volts 50 Hz
Supply only LTXL capacitor power heavy duty 50 kVAr 415 volts 50 Hz
Supply only Capacitor microf 4.17 kVAr overpressure disconnector all as specified and directed
Supply only Contact (Make ABB UA 30-30-10RA) all as specified and directed
Supply only HBC fuse link model no ISHTIS0063(A3) make Standard 63 Amps 415 Volts 50 Hz 80 kA suitable for 125 kVAr capacitor bank Make Standard all as specified and directed
Supply only APFC relay advance range VPL06N all as specified and directed
Supply only (reactive power management) Relay automatic C/k setting of over voltage, over compensation, make Neptune RM-8 for 125 kVAr capacitor bank all as specified and directed
Supply only indication lamp for Phases (RYB) all as specified and directed
Supply only indication lamp (Red) for 25 kVAr capacitor bank all as specified and directed
Supply only indication lamp (Green) for start suitabnle for 125 kVAr capacitor bank ll as specified and directed
Supply only indication lamp (red) for stop suitabnle for 125 kVAr capacitor bank ll as specified and directed
Supply only Ameter meter make Neptune all as specified and directed
Supply only tharmostate all as specified and directed
Supply only contactors Telemecooique LC1 D.K all as specified and directed
Supply only HRC fuse HN size 160 Amps 415 volts 100 kA Make : L&T
Supply only metering current transformer of 630/5 Amps for RYB phase all all as specified and directed.
Supply only (reactive power management) Relay automatic C/k setting of over voltage, over compensation, Make Neptune RM-8 for 125 kVAr capacitor bank
Supply only Contact 32 Amps Telemecanique LC1-DGK11.C 32 Amps model A012851, Make Schneider electric all as specified and directed
Supply only Contact 80 Amps Telemecanique LC1-DGK11.C 32 Amps model A012851 make Schneider electric all as specified and directed
Supply only Contact 60 Amps Telemecanique LC1-DGK11.C 32 Amps model A012851 make Schneider electric all as specified and directed
Supply only Space heater 415/220 volt suitable for 100 to 500 kVAr capacitor bank all as specified and directed
Supply only (reactive power management) Relay suitable for automatic C/k setting controll of over voltage compensation insufficient compensation 200 kVAr capacitor bank make & model Schneider electric Varlogic RT-8 all as specified and directed
Supply only HBC back up protection by suitable HRC fuse units along with HRC fuse 6 Amps Make Standard
Supply only MCB Tp D-50 make Schneider
Supply only MCB Tp D- 25 make Schneider
Supply and fix Air circuit Breaker (ACB) 4 pole 415 volt, with thermal magnetic release mannual draout type of capacity 1600 Amps 50, KA all as specified and directed (Make- L&T Cat no MDO SL96044 or equivalent to Schneider / Indo Asian)
All as per item No 32.00 above but capacity of 1250 Amps. (Make- L&T Cat no MDO SL96042 or equivalent to schneider/Indo Asian)
Supply, install, test and commissioning MCCB with fixed thermal maganetic relase for 415 V, 50 Hz AC supply of 400 Amp, 4 pole 50 KA rated capacity by taking out old unserviceable MCCB's all as specified and directed. Make : Make : Indo Asian /L&T/ABB / Schneider
All as per item No 34.00 above but of capacity 250 Amps, breaking capacity 36 kA
All as per item No 34.00 above but of capacity 200 Amps, breaking capacity 36 kA
All as per item No 34.00 above but of capacity 125 Amps, breaking capacity 16 kA
All as per item No 34.00 above but of capacity 100 Amps, breaking capacity 16 kA
All as per item No 34.00 above but of capacity 160 Amps, breaking capacity 25 kA
All as per item No 34.00 above but of capacity 63 Amps, breaking capacity 25 kA
Dimantling, taking out all earth connection of strip from panel board to earth test pint any size and replace the worn out earth strip, nut/bolts/washers connect all joint with new nots,bolts and washers to in original position all as specified and directed. Note :- Earth GI strip measured and paid separetely
Supply only Earth continuity conductor GI strip of sizep 32 X 6 mm
M&L for repair to damaged eaarthing pit after breaking and taking out all debries, removing debries to low laying area and making proper pit as per SSR-I, plate NO-3 using PCC 1:3:6 and CI cover with nnecessary frame work complete all as specified and directed
SOWRYA CONSTRUCTIONS
R AND A ASSOCIATES ENGINEERS CONTRACTORS
M/s SS Engineering Enterprises
POWERTECH ENGINEERING SERVICES
SRIESWARI ENTERPRISES
M/S EVEREST INFRA
ANJANA ENTERPRISES
SUPREET CONSTRUCTIONS
MVV Prasad
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .