Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.3 LAccepted-AOC 894 NEAR 132 KV POWER HOUSE SINDHARI ROAD BALDEV NAGAR BARMER RAJ 344001 | BARMER | RAJASTHAN | 344001 | L1 | Accepted-AOC AOC | |
| 2 | L2₹22.9 L+₹2.4 L (11.7%)Rejected-Finance H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹23.8 L+₹3.4 L (16.4%)Rejected-Finance MANGERIYA MANGERIYA BHOPALGARGH JODHPUR 342901 | JODHPUR | JODHPUR | RAJASTHAN | 342901 | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹24.7 L+₹4.2 L (20.6%)Rejected-Finance | L4 | Rejected-Finance Not lowest bidder | |
| 5 | L5₹25.6 L+₹5.1 L (25.0%)Rejected-Finance 145H 2G AQAMA MODEL APARTMENT LUKERGANJ PRAYAGRAJ UTTAR PRADESH | PRAYAGRAJ | UTTAR PRADESH | 211001 | L5 | Rejected-Finance Not lowest bidder |
| Sl No | Description | Qty | Unit | Shri Electrical Enterprises L2 | Surendra Singh L4 | M/s JOG SINGH MATERIALS L3 | DIWAKAR CONSTRUCTION CO. L6 | GITANSH ENGINEERS AND COMPANY L1 | yash enterprises L5 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down old unserviceable/worn out sub main wiring/service wire of any type and size complete all as specified. | 700 | RM | 20 ₹14,000 | 20 ₹14,000 | 10 ₹7,000 | 20 ₹14,000 | 5 ₹3,500 Lowest | 31 ₹21,700 |
| 2.00 | M & L in replacement for Sub main wiring complete with single core 1.5sqmm,1100 volts grade, PVC insulated, stranded copper conductor ZHFR cable with continuous copper earth conductor of 1.5 sqmm in and including Steel conduit on surface and accessories complete including necessary connection to existing MCB/Flame proofswitch/Flame proof light fittings/Flame proof Sockets etc all as specified. (Note:- (i) Making good of disturbed surfaces will be done by contractor without any claims. (ii) 3 runs of 1.5 Sqmm conductor(P+N+E) and one run of steel conduit shall be measured as one unit length.) | 150 | RM | 255 ₹38,250 | 290 ₹43,500 | 130 ₹19,500 Lowest | 350 ₹52,500 | 333 ₹49,950 | 701 ₹1,05,150 |
| 3.00 | M & L in replacement for Sub main wiring complete with single core 1.5sqmm,1100 volts grade, PVC insulated, stranded copper conductor ZHFR cable with continuous copper earth conductor of 1.5 sqmm in existing steel/PVC conduit on surface/concealed and accessories complete including necessary connection to existing MCB/Flame proofswitch/Flame proof light fittings/Flame proof Sockets etc all as specified. (Note:- (i) Making good of disturbed surfaces will be done by contractor without any claims. (ii) 3 runs of 1.5 Sqmm conductor(P+N+E) and one run of conduit shall be measured as one unit length.) | 150 | RM | 255 ₹38,250 | 240 ₹36,000 | 100 ₹15,000 Lowest | 290 ₹43,500 | 299 ₹44,850 | 1,251 ₹1,87,650 |
| 4.00 | M & L in replacement for Sub main wiring complete with single core 2.5 sqmm,1100 volts grade, PVC insulated, stranded copper conductor ZHFR cable with continuous copper earth conductor of 2.5 sqmm in and including Steel conduit on surface and accessories complete including necessary connection to existing MCB/Flame proofswitch/Flame proof light fittings/Flame proof Sockets etc all as specified. (Note:- (i) Making good of disturbed surfaces will be done by contractor without any claims. (ii) 3 runs of 2.5 Sqmm(P+N+E) conductor and one run of steel conduit shall be measured as one unit length.) | 90 | RM | 355 ₹31,950 | 390 ₹35,100 | 215 ₹19,350 Lowest | 450 ₹40,500 | 499 ₹44,910 | 2,000 ₹1,80,000 |
| 5.00 | M & L in replacement for Sub main wiring complete with single core 2.5 sqmm,1100 volts grade, PVC insulated, stranded copper conductor ZHFR cable with continuous copper earth conductor of 2.5 sqmm in existing steel/PVC conduit on surface/concealed and accessories complete including necessary connection to existing MCB/Flame proofswitch/Flame proof light fittings/Flame proof Sockets etc all as specified. (Note:- (i) Making good of disturbed surfaces will be done by contractor without any claims. (ii) 3 runs of 2.5 Sqmm conductor and one run of conduit shall be measured as one unit length.) | 90 | RM | 355 ₹31,950 | 350 ₹31,500 | 175 ₹15,750 Lowest | 350 ₹31,500 | 444 ₹39,960 | 2,000 ₹1,80,000 |
| 6.00 | M & L in replacement for Sub main wiring complete with single core 4 sqmm,1100 volts grade, PVC insulated, stranded copper conductor ZHFR cable with continuous copper earth conductor of 4 sqmm in and including steel conduit on surface incl accessories complete including necessary connection to existing MCB/Flame proofswitch/Flame proof light fittings/Flame proof Sockets etc all as specified. (Note:- (i) Making good of disturbed surfaces will be done by contractor without any claims. (ii) 3 runs of 4 Sqmm conductor(P+N+E) and one run of steel conduit shall be measured as one unit length.) | 60 | RM | 455 ₹27,300 | 510 ₹30,600 | 315 ₹18,900 Lowest | 525 ₹31,500 | 566 ₹33,960 | 500 ₹30,000 |
| 7.00 | M & L in replacement for Sub main wiring complete with two single core 4 sqmm,1100 volts grade, PVC insulated, stranded copper conductor ZHFR cable with continuous copper earth conductor of 4 sqmm in existing steel/PVC conduit on surface/concealed incl accessories complete including necessary connection to existing MCB/Flame proofswitch/Flame proof light fittings/Flame proof Sockets etc all as specified. (Note:- (i) Making good of disturbed surfaces will be done by contractor without any claims. (ii) 3 runs of 4 Sqmm conductor(P+N+E) and one run of conduit shall be measured as one unit length.) | 60 | RM | 455 ₹27,300 | 480 ₹28,800 | 265 ₹15,900 Lowest | 425 ₹25,500 | 555 ₹33,300 | 800 ₹48,000 |
| 8.00 | M & L in replacement for Sub main wiring complete with single core 6 sqmm,1100 volts grade, PVC insulated, stranded copper conductor ZHFR cable with continuous copper earth conductor of 6 sqmm in and including steel conduit on surface and accessories complete including necessary connection to existing MCB/Flame proofswitch/Flame proof light fittings/Flame proof Sockets etc all as specified. (Note:- (i) Making good of disturbed surfaces will be done by contractor without any claims. (ii) 3 runs of 6 Sqmm conductor(P+N+E) and one run of steel conduit shall be measured as one unit length.) | 50 | RM | 555 ₹27,750 | 650 ₹32,500 | 500 ₹25,000 Lowest | 650 ₹32,500 | 699 ₹34,950 | 1,000 ₹50,000 |
| 9.00 | M & L in replacement for Sub main wiring complete with single core 6 sqmm,1100 volts grade, PVC insulated, stranded copper conductor ZHFR cable with continuous copper earth conductor of 6 sqmm in existing steel/PVC conduit on surface/concealed and accessories complete including necessary connection to existing MCB/Flame proofswitch/Flame proof light fittings/Flame proof Sockets etc all as specified. (Note:- (i) Making good of disturbed surfaces will be done by contractor without any claims. (ii) 3 runs of 6 Sqmm conductor(P+N+E) and one run of conduit shall be measured as one unit length.) | 50 | RM | 555 ₹27,750 | 590 ₹29,500 | 410 ₹20,500 Lowest | 550 ₹27,500 | 666 ₹33,300 | 1,200 ₹60,000 |
| 10.00 | Taking down & Supply and replacement of flame proof and dust proof junction box made up of Die cast Aluminium alloy LM6 4 way IP 65 CMRI certified complete all as directed. | 60 | Each | 1,000 ₹60,000 | 1,100 ₹66,000 | 900 ₹54,000 | 1,500 ₹90,000 | 700 ₹42,000 | 651 ₹39,060 Lowest |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
30 Jun 2026, 6:00 pmClosed
Garrison Engineer, Banar
Garrison Engineer Banar, Jodhpur-342027
REPAIR AND MAINT OF FLAME PROOF WIRINGS AND CONNECTED ITEMS IN STORAGE ESH SHEDS ETC IN A A BANAR UNDER GE BANAR
2026_MES_771602_1
8826/23/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
BANAR
As per nit and tender documents
8 documents required · 8 mandatory
₹500
Garrison Engineer Banar
₹50,000
Yes
28 Sept 2026
11 Jun 2026
2 Jul 2026
11 Jun 2026
30 Jun 2026
25 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down old unserviceable/worn out sub main wiring/service wire of any type and size complete all as specified. | 700 | RM | - | - |
| 2 | M & L in replacement for Sub main wiring complete with single core 1.5sqmm,1100 volts grade, PVC insulated, stranded copper conductor ZHFR cable with continuous copper earth conductor of 1.5 sqmm in and including Steel conduit on surface and accessories complete including necessary connection to existing MCB/Flame proofswitch/Flame proof light fittings/Flame proof Sockets etc all as specified. (Note:- (i) Making good of disturbed surfaces will be done by contractor without any claims. (ii) 3 runs of 1.5 Sqmm conductor(P+N+E) and one run of steel conduit shall be measured as one unit length.) | 150 | RM | - | - |
| 3 | M & L in replacement for Sub main wiring complete with single core 1.5sqmm,1100 volts grade, PVC insulated, stranded copper conductor ZHFR cable with continuous copper earth conductor of 1.5 sqmm in existing steel/PVC conduit on surface/concealed and accessories complete including necessary connection to existing MCB/Flame proofswitch/Flame proof light fittings/Flame proof Sockets etc all as specified. (Note:- (i) Making good of disturbed surfaces will be done by contractor without any claims. (ii) 3 runs of 1.5 Sqmm conductor(P+N+E) and one run of conduit shall be measured as one unit length.) | 150 | RM | - | - |
| 4 | M & L in replacement for Sub main wiring complete with single core 2.5 sqmm,1100 volts grade, PVC insulated, stranded copper conductor ZHFR cable with continuous copper earth conductor of 2.5 sqmm in and including Steel conduit on surface and accessories complete including necessary connection to existing MCB/Flame proofswitch/Flame proof light fittings/Flame proof Sockets etc all as specified. (Note:- (i) Making good of disturbed surfaces will be done by contractor without any claims. (ii) 3 runs of 2.5 Sqmm(P+N+E) conductor and one run of steel conduit shall be measured as one unit length.) | 90 | RM | - | - |
| 5 | M & L in replacement for Sub main wiring complete with single core 2.5 sqmm,1100 volts grade, PVC insulated, stranded copper conductor ZHFR cable with continuous copper earth conductor of 2.5 sqmm in existing steel/PVC conduit on surface/concealed and accessories complete including necessary connection to existing MCB/Flame proofswitch/Flame proof light fittings/Flame proof Sockets etc all as specified. (Note:- (i) Making good of disturbed surfaces will be done by contractor without any claims. (ii) 3 runs of 2.5 Sqmm conductor and one run of conduit shall be measured as one unit length.) | 90 | RM | - | - |
| 6 | M & L in replacement for Sub main wiring complete with single core 4 sqmm,1100 volts grade, PVC insulated, stranded copper conductor ZHFR cable with continuous copper earth conductor of 4 sqmm in and including steel conduit on surface incl accessories complete including necessary connection to existing MCB/Flame proofswitch/Flame proof light fittings/Flame proof Sockets etc all as specified. (Note:- (i) Making good of disturbed surfaces will be done by contractor without any claims. (ii) 3 runs of 4 Sqmm conductor(P+N+E) and one run of steel conduit shall be measured as one unit length.) | 60 | RM | - | - |
| 7 | M & L in replacement for Sub main wiring complete with two single core 4 sqmm,1100 volts grade, PVC insulated, stranded copper conductor ZHFR cable with continuous copper earth conductor of 4 sqmm in existing steel/PVC conduit on surface/concealed incl accessories complete including necessary connection to existing MCB/Flame proofswitch/Flame proof light fittings/Flame proof Sockets etc all as specified. (Note:- (i) Making good of disturbed surfaces will be done by contractor without any claims. (ii) 3 runs of 4 Sqmm conductor(P+N+E) and one run of conduit shall be measured as one unit length.) | 60 | RM | - | - |
| 8 | M & L in replacement for Sub main wiring complete with single core 6 sqmm,1100 volts grade, PVC insulated, stranded copper conductor ZHFR cable with continuous copper earth conductor of 6 sqmm in and including steel conduit on surface and accessories complete including necessary connection to existing MCB/Flame proofswitch/Flame proof light fittings/Flame proof Sockets etc all as specified. (Note:- (i) Making good of disturbed surfaces will be done by contractor without any claims. (ii) 3 runs of 6 Sqmm conductor(P+N+E) and one run of steel conduit shall be measured as one unit length.) | 50 | RM | - | - |
| 9 | M & L in replacement for Sub main wiring complete with single core 6 sqmm,1100 volts grade, PVC insulated, stranded copper conductor ZHFR cable with continuous copper earth conductor of 6 sqmm in existing steel/PVC conduit on surface/concealed and accessories complete including necessary connection to existing MCB/Flame proofswitch/Flame proof light fittings/Flame proof Sockets etc all as specified. (Note:- (i) Making good of disturbed surfaces will be done by contractor without any claims. (ii) 3 runs of 6 Sqmm conductor(P+N+E) and one run of conduit shall be measured as one unit length.) | 50 | RM | - | - |
| 10 | Taking down & Supply and replacement of flame proof and dust proof junction box made up of Die cast Aluminium alloy LM6 4 way IP 65 CMRI certified complete all as directed. | 60 | Each | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.27 MB
TenderPage1.pdf
Tender Documents • 0.26 MB
TenderPage.pdf
Tender Documents • 0.69 MB
BOQ_864036.xls
BOQ • 11.94 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .