Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.1 LAccepted-AOC | ₹26.1 L | L1 | Accepted-AOC Being Lowest Vendor |
| 2 | L2₹30.5 LRejected-Finance | ₹30.5 L | L2 | Rejected-Finance Being not L1 |
| 3 | L3₹32.0 LRejected-Finance DOOR NO 57 28 10 4 2 BHAVANI GARDENS INDUSTRIAL ESTATE POST VISAKHAPATNAM 530 007 | VISAKHAPATANAM | ANDHRA PRADESH | 530007 | ₹32.0 L | L3 | Rejected-Finance Being not L1 |
| 4 | L4₹34.9 LRejected-Finance | ₹34.9 L | L4 | Rejected-Finance Being not L1 |
| 5 | L5₹35.0 LRejected-Finance | ₹35.0 L | L5 | Rejected-Finance Being not L1 |
| Sl No | Description | Qty | Unit | SAI SREENIVASA ENGINEERING L5 | GVR ENGINEERING WORKS L10 | Power Dynamics L9 | R AND A ASSOCIATES ENGINEERS CONTRACTORS L7 | SIRI CONSTRUCTION L1 | MSN ENGINEERING WORKS L6 | aswitha engineering works L2 | LND Enterprises L8 | B.Veerabhadra Rao L4 | B SRINIVAS L3 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Repair/maintinance of multiple section of LT Panel board at indoor substation comprising minimum up to 10 Nos ACBs/ MCCBs/SDFs ,busbar chamber, swich gear chamber, metering chamber cable termination/tray chamber after opening front/top/side/back cover by using forced air pressure and brushes, cleaning of all dust/durt, complete cleaning of out side surface of panel board using suitable cleaning agents, tighting of all nuts & bolts of busbar/switchgear, repair/replacement to defective metering wiring from ACB/MCCB/CT to meter and replacement of defective meters, CTs, indicator lamp, metering terminal blocks, MCB, replacement of all aluminum cable lugs, nuts-bolts-washers, replacement of defective Panel knob/door knob and hinges all as specified and directed for
Note:- (i) Panel Meter, indicator lamp, MCB,busbar and CT will be measured and paid seperately as supply only. (ii) required aluminium cable lugs, metering cables and nuts-bolts-washers shall be inclusive of quoted rate. (iii) Servicing/maintinance of ACBs measured seperatelly. (iv) cable connection disconnection included inclusive of quoted rate. | 10 | Each Job | 2,500 ₹25,000 | 4,000 ₹40,000 | 7,500 ₹75,000 | 1,200 ₹12,000 | 3,700 ₹37,000 | 5,000 ₹50,000 | 2,516.82 ₹25,168.22 | 3,725 ₹37,250 | 1,899 ₹18,990 | 2,000 ₹20,000 |
| 2.00 | All as per item No. 1.00 above, but comprising ACBs /MCCBs/SDFs up to total 15 Nos | 11 | Each Job | 3,200 ₹35,200 | 4,300 ₹47,300 | 8,500 ₹93,500 | 1,200 ₹13,200 | 3,160 ₹34,760 | 5,500 ₹60,500 | 3,451.42 ₹37,965.62 | 5,108 ₹56,188 | 2,799 ₹30,789 | 4,500 ₹49,500 |
| 3.00 | All as per item No. 1.00 above, but comprising ACBs /MCCBs/SDFs up to total 21 Nos | 15 | Each Job | 4,600 ₹69,000 | 4,600 ₹69,000 | 10,000 ₹1,50,000 | 1,200 ₹18,000 | 6,400 ₹96,000 | 7,000 ₹1,05,000 | 7,097.29 ₹1,06,459.41 | 10,505 ₹1,57,575 | 3,699 ₹55,485 | 7,000 ₹1,05,000 |
| 4.00 | Repair, maintinance of Air Circuit Breaker 630 Amps to 3200 Amps capacity by drawing out movable unit, forced air cleaning of movable and fixed unit, decarbonize breaker contracts and checking for any defects due to any flush/loose contact, cleaning of all fixed and moving contact point, terminal connection points with CTC, replacement of defective parts and re-fixing ACB, cables completes all as specified and directed.
Note: (a) Required male/female ACB contacts, trip coils, closing coils, electronic protection unit will be measured as supply only. (b) All cleaning agents are included in the quoted rate. (c) Cable connection and disconnection are included in the quoted rate. | 30 | Each Job | 1,250 ₹37,500 | 4,600 ₹1,38,000 | 5,000 ₹1,50,000 | 800 ₹24,000 | 1,720 ₹51,600 | 3,500 ₹1,05,000 | 3,391.5 ₹1,01,745 | 2,927 ₹87,810 | 999 ₹29,970 | 2,300 ₹69,000 |
| 5.00 | Supply only fixed contract of ACB 630A to 3200A all as specified and directed. | 6 | Each | 1,535 ₹9,210 | 5,500 ₹33,000 | 5,000 ₹30,000 | 2,800 ₹16,800 | 730 ₹4,380 | 3,500 ₹21,000 | 1,418.35 ₹8,510.1 | 1,224 ₹7,344 | 750 ₹4,500 | 1,683.86 ₹10,103.16 |
| 6.00 | Supply only Moving contract of ACB 630A to 3200A all as specified and directed. | 4 | Each | 2,100 ₹8,400 | 3,500 ₹14,000 | 5,000 ₹20,000 | 2,100 ₹8,400 | 1,450 ₹5,800 | 3,000 ₹12,000 | 1,618.23 ₹6,472.94 | 2,395 ₹9,580 | 1,200 ₹4,800 | 3,717 ₹14,868 |
| 7.00 | Supply only Electronic protection unit of ACB 630A to 3200A all as specified and directed. | 6 | Each | 9,900 ₹59,400 | 63,000 ₹3,78,000 | 15,000 ₹90,000 | 4,000 ₹24,000 | 4,600 ₹27,600 | 3,000 ₹18,000 | 4,961.62 ₹29,769.74 | 7,343 ₹44,058 | 7,000 ₹42,000 | 9,000 ₹54,000 |
| 8.00 | Supply only shunt trip coil of ACB 630A to 3200A all as specified and directed. | 2 | Each | 4,500 ₹9,000 | 3,500 ₹7,000 | 2,350 ₹4,700 | 4,000 ₹8,000 | 3,700 ₹7,400 | 3,200 ₹6,400 | 7,034.75 ₹14,069.5 | 6,072 ₹12,144 | 5,000 ₹10,000 | 6,676 ₹13,352 |
| 9.00 | Supply only closing coil ACB 630A to 3200A all as specified and directed. | 2 | Each | 4,600 ₹9,200 | 4,800 ₹9,600 | 2,350 ₹4,700 | 4,000 ₹8,000 | 3,700 ₹7,400 | 3,000 ₹6,000 | 7,034.75 ₹14,069.5 | 6,072 ₹12,144 | 5,000 ₹10,000 | 6,676 ₹13,352 |
| 10.00 | Supply only digital electronic Ammeter (0-3200 amps range) with built in selector switch suitable for LT 415 V panel flush pattern square type 96 mm x 96 mm with adopter complete all as specified and directed.
Make :- Cat Part No:-30002385 (DM3110) of Schneider or Conserve/L&T/HPL | 14 | Each | 1,600 ₹22,400 | 1,350 ₹18,900 | 1,300 ₹18,200 | 1,300 ₹18,200 | 730 ₹10,220 | 1,700 ₹23,800 | 1,482.95 ₹20,761.3 | 1,280 ₹17,920 | 900 ₹12,600 | 1,430.16 ₹20,022.24 |
Tender Value
₹49.4 L
EMD Value
₹98,780
Closing Date
23 Mar 2026, 6:30 pmClosed
GE (I) DM Visakhapatnam
GE (I) DM Visakhapatnam
REPAIR MAINTENANCE OF LT ELECTRICAL PANEL BOARDS AND ALL ACCESSORIES INCLUDING REPLACEMENT OF UNSV ITEMS GALLERY EARTHINGS EARTHING STRIPS AND ALLIED WORKS AT OLD DOCKYARD JETTY SUBSTATIONS AT NAVAL DOCKYARD VISAKHAPATNAM UNDER GE (I) (DM) VISAKHAP
2026_MES_753808_1
8464/C/E8
Open Tender
Electrical and Maintenance Works
180 days
Naval Dockyard Visakhapatnam
As per tender document
8 documents required · 8 mandatory
₹500
GE (I) DM Visakhapatnam
₹98,780
Yes
4 Jun 2026
23 Feb 2026
25 Mar 2026
23 Feb 2026
23 Mar 2026
9 Mar 2026
24 Feb 2026 - 14 Mar 2026
Repair/maintinance of multiple section of LT Panel board at indoor substation comprising minimum up to 10 Nos ACBs/ MCCBs/SDFs ,busbar chamber, swich gear chamber, metering chamber cable termination/tray chamber after opening front/top/side/back cover by using forced air pressure and brushes, cleaning of all dust/durt, complete cleaning of out side surface of panel board using suitable cleaning agents, tighting of all nuts & bolts of busbar/switchgear, repair/replacement to defective metering wiring from ACB/MCCB/CT to meter and replacement of defective meters, CTs, indicator lamp, metering terminal blocks, MCB, replacement of all aluminum cable lugs, nuts-bolts-washers, replacement of defective Panel knob/door knob and hinges all as specified and directed for Note:- (i) Panel Meter, indicator lamp, MCB,busbar and CT will be measured and paid seperately as supply only. (ii) required aluminium cable lugs, metering cables and nuts-bolts-washers shall be inclusive of quoted rate. (iii) Servicing/maintinance of ACBs measured seperatelly. (iv) cable connection disconnection included inclusive of quoted rate.
All as per item No. 1.00 above, but comprising ACBs /MCCBs/SDFs up to total 15 Nos
All as per item No. 1.00 above, but comprising ACBs /MCCBs/SDFs up to total 21 Nos
Repair, maintinance of Air Circuit Breaker 630 Amps to 3200 Amps capacity by drawing out movable unit, forced air cleaning of movable and fixed unit, decarbonize breaker contracts and checking for any defects due to any flush/loose contact, cleaning of all fixed and moving contact point, terminal connection points with CTC, replacement of defective parts and re-fixing ACB, cables completes all as specified and directed. Note: (a) Required male/female ACB contacts, trip coils, closing coils, electronic protection unit will be measured as supply only. (b) All cleaning agents are included in the quoted rate. (c) Cable connection and disconnection are included in the quoted rate.
Supply only fixed contract of ACB 630A to 3200A all as specified and directed.
Supply only Moving contract of ACB 630A to 3200A all as specified and directed.
Supply only Electronic protection unit of ACB 630A to 3200A all as specified and directed.
Supply only shunt trip coil of ACB 630A to 3200A all as specified and directed.
Supply only closing coil ACB 630A to 3200A all as specified and directed.
Supply only indication lamps (LED type) red, yellow and blue in colours of 22.5 mm dia to monitor on LT panel board suitable for 240 V AC supply and taking down unserviceable indication lamps all as specified and directed. Cat Part No:-1SFA619402R5201of Siemens or C&S/schneider/ABB
Supply only metering current transformer of 2500/5 Amps class-1, 15 VA, all as specified and directed.
Supply only metering current transformer of 2000/5 Amps class-1, 15 VA, all all as specified and directed.
Supply only metering current transformer of 1600/5 Amps class-1, 12.5 VA, all all as specified and directed.
Supply only three (3) Phase, multifunction power and energy meter with Class 0.5S /1.0 as per IEC 62053-22 / 21 with IO module integration for onboard data logging for real time montioring of following parameters Amps, PF, THD, Hz, W, Wh, VA, VAh, VAR, VARh, min/max demand monitoring with communication port RS485 all as specified and directed.
M & L for ACB 4 Pole, 415 V, with Thermal Magnetic Release (Manual Drawout type) of capacity 3200 Amps and taking down unserviceable all as specified and directed.
M & L for ACB 4 Pole, 415 V, with Thermal Magnetic Release (Manual Drawout type) of capacity 2500 Amps and taking down unserviceable all as specified and directed.
M & L for ACB 4 Pole, 415 V, with Thermal Magnetic Release (Manual Drawout type) of capacity 2000 Amps and taking down unserviceable all as specified and directed.
M & L for ACB 4 Pole, 415 V, with Thermal Magnetic Release (Manual Drawout type) of capacity 1600 Amps and taking down unserviceable all as specified and directed.
M & L for ACB 3 Pole, 415 V, with Thermal Magnetic Release (Manual Drawout type) of capacity 3200 Amps and taking down unserviceable all as specified and directed.
M & L for ACB 3 Pole, 415 V, with Thermal Magnetic Release (Manual Drawout type) of capacity 2500 Amps and taking down unserviceable all as specified and directed.
M & L for ACB 3 Pole, 415 V, with Thermal Magnetic Release (Manual Drawout type) of capacity 2000 Amps and taking down unserviceable all as specified and directed.
M & L for ACB 3 Pole, 415 V, with Thermal Magnetic Release (Manual Drawout type) of capacity 1600 Amps and taking down unserviceable all as specified and directed.
M & L for ACB 3 Pole, 415 V, with Thermal Magnetic Release (Manual Drawout type) of capacity 1250 Amps and taking down unserviceable all as specified and directed.
M & L for ACB 3 Pole, 415 V, with Thermal Magnetic Release (Manual Drawout type) of capacity 1000 Amps and taking down unserviceable all as specified and directed.
M & L for ACB 3 Pole, 415 V, with Thermal Magnetic Release (Manual Drawout type) of capacity 800 Amps and taking down unserviceable all as specified and directed.
M & L for MCCB 3 Pole, 415 V, with Thermal Magnetic Release (Manual Drawout type) of capacity 630 Amps with breaking capacity 50 KA and taking down unserviceable all as specified and directed.
M & L for MCCB 3 Pole, 415 V, with Thermal Magnetic Release (Manual Drawout type) of capacity 400 Amps with breaking capacity 36 KA and taking down unserviceable all as specified and directed.
Supply and fix heat shrikable cable end termination of sizes 300/ 400 sqmm, 3.5 core complete all as specified and directed.
Supply and fix heat shrikable cable end termination of sizes 185/240 sqmm, 3.5 core complete all as specified and directed.
Supply only Heat Shrink sleeve outer protection insulating tube (Coated) single core, for application range 9-29mm all as specified and directed.
Supply only coloured Heat Shrink sleve busbar insulation tube single core, for application range upto 150 mm all as specified and directed.
Supply only Busbar anodised aluminium of as per site requirement sizes including required drilling holes for fixing with other bus / cable connections all as specified and directed.
Supply only Busbar anodised copper of as per site requirement sizes including drilling holes for fixing with other bus / cable connections all as specified and directed.
Supply and fix MS cable support structure made with ISA 75x75x8mm grouted to gallery wall with angle fastner bolt of dia not less than 16 mm at interval of 300 mm fixing of cross support with cadmium coating bolts not less than 12 mm dia,painting the MS structure with one coat of red oxide primer and two coat of synthetic enamel paint complete including taking out old UNSV cable support structure from the jetty gallery complete all as specified and as directed.
M&L for MS Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachmens complete all as specified and as directed including taking out of old unserviceable MS cable cover/support structure.Grade of steel Fe 410 -W (Gde E- 250) quality -A structure all as specified and directed.
M&L for painting of outer surface of multiple section of complete LT Panel board size up to 5.5 m x 3.2 in substation Panel board comprising ACBs/MCCBs/SDFs ,busbar chamber, swich gear chamber, metering chamber cable termination/tray using one coat of synthetic enamel paint after preparation of surface, providing protection cover to all metering equipment, panel meters, switchgears, cleaning of all meters and switch gears complete all as specified and as directed
Cleaning of cable duct of size 1.2 x 1.0 by removing out all mud, soil, waste materials and disposal of waste materials outside Dockyard area complete all as specified and directed
Supply and fix line diagram of substation panel to Jetty panel and cope point with blue background and white letter made with retro reflective sheet and pasted on 2 mm thick aluminium sheet of total size 0.45 m high X 5.5 mtr long fixed to MS fabricated structure with welding, nuts, bolts complete including dismantling taking old unserviceable glow sign board of any type complete all as specified and directed.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.39 MB
8464Tender.pdf
Tender Documents • 1.15 MB
BOQ_844310.xls
BOQ • 0.44 MB
Download all tender documents and submit your bid