| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.2 LAccepted-AOC SHOP NO 1 KARGI CHOWK HARIDWAR BY PASS DEHRADUN UTTARAKHAND | L1 | Accepted-AOC ACEEPTED BEING LOWEST TENDER | |
| 2 | L2₹23.7 L+₹22,126.50 (0.94%)Rejected-AOC A 1 BLOCK 2 HATHITHAN HATHITHAN VILLAGE TOWN JALALNAGAR CITY SHAHJAHANPUR SHAHJAHANPUR UTTAR PRADESH 242001 INDIA | SHAHJAHANPUR | UTTAR PRADESH | 242001 | L2 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER | |
| 3 | L3₹23.9 L+₹33,362.50 (1.42%)Rejected-AOC | L3 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER | |
| 4 | L4₹24.4 L+₹86,685.50 (3.69%)Rejected-AOC | L4 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER | |
| 5 | L5₹24.6 L+₹1.1 L (4.47%)Rejected-AOC 800 RAM NAGAR ROORKEE DISTT HARIDWAR UK PIN 247667 | ROORKEE | HARIDWAR | UTTARAKHAND | 247667 | L5 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER |
Tender Value
₹25.5 L
EMD Value
₹51,000
Closing Date
13 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I RND DEHRADUN
GE I RND DEHRADUN DEAL RESIDENTIAL COMPLEX RAIPUR ROAD DEHRADUN 248008
RE-APPROPRIATION OF 08 NOS OF MARRIED OFFICERS HOSTEL (P-38) IN TO 04 NOS OF TYPE IV MARRIED ACCN INCLUDING GARRAGES AT DRDO RESIDENTIAL COMPLEX SANCHAR VIHAR UNDER GE(I) R N D DEHRADUN
2021_MES_483554_1
GE(I)RND/9079/E8/21-22
Open Tender
Civil Works
Item Rate
180 days
DEHRADUN
Class D Category b (i) FOR UNENLISTED CONTRACTOR (i) Enlistment criteria may be seen in Para 1.4 of section of Part I of MES Manual on contracts-2007 (Reprint 2012) as available in all MES formations (ii) Copy of police verification /passport.
6 documents required · 6 mandatory
₹500
GE I R N D DEHRADUN
₹51,000
Yes
18 Dec 2021
23 Oct 2021
15 Nov 2021
23 Oct 2021
13 Nov 2021
30 Oct 2021
23 Oct 2021 - 30 Oct 2021
60 days
Amount
Demolition of Brickwork or stone/boulder masonry, built in ncement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles etc complete all as spd and directed.
M & L Brickwork Cement mortor 1:4 with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in etc complete all as spd and directed.
M & L Brickwork cement mortor 1:4 with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in etc complete all as spd and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M/L non-skid ceremic tiles coloured 7 to 8mm thick (square/rectangular) area of eac tile exc 0.11sqm but n exc 0.18 sqm, in floors, set & jointed in neat cement slurry and pointed in coloured cement to match coloured tiles including for Screed bed (or) bedding layer of mortar 15mm thick for laying floor finishes CM (1:6) complete all as specified and directed.
M & L for light shade , Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match on and a bedding layer of screed bed 15 mm thick in CM 1:6 as specified. etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including for Screed bed (or) bedding layer of mortar 15 mm thick for laying floor finishes CM (1:6) complete all as specified and directed.
All as per item No-06 but in skirting over 10 mm thick back coat in 1:4 CM complete all as specified and directed.
M & L for Coloured Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 10 mm thick rendering in CM 1:6 complete all as specified etc completed all as specified.
Demolation of stone slab and tiles of any description or thickness laid beded and pointed in floors aprons etc
M & L Granite (of any type) work (table rubbed and polished) 20 mm thick in steps, jambs, pillars, window-cills, cooking platforms and like in over and including screed bed 15 mm thick in cement mortar (1:6) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, etc complete all spd and directed.
Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc completed all as specified.
M&L rendering 10mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces & finishing the surface even & smooth without using extra cement complete all as specified & directed.
M & L rendering 15mm thick on wall in cement mortar 1:4 finished fair and even smooth without using extra cement complete all as specified.
M/L for preparation of new plastered surfaces of walls and priming with chalk whitining on plastered surface and applying two coat of oil emulsion distemper with thin layer of putty/POP complete all as specified and as directed.
M&L complete removal of existing treatment and preparing old surfaces or newly plastered surface and applying 2 coat of weather proof extrior emulsion paint over a coat extrior primer (Asian paint/ Berger) including a coat of white cement based puty complete all as specified.
Preparing old decorated or undecorated surfaces by brooming down of steel wire brushing, scrapping down moulds mass and efforescent salt and treating oil greasy spots and stopping of distemper and applying one coat of oil emulsion (bound) distemper with thin layer of putty/POP on wall complete all as specified and as directed.
Demolition of reinforced cement concrete, (other than ground floors), shelves, chajjas, slabs and similar work carefully and matching to adjoining disturbed surfaces all as directed.
M&L precast RCC 1:2:4 type B1 as in landings, cover slab,chajjas etc.and similar articles with plain faces set in CM 1:6 complete all as specified and directed.
Form work to soffits of suspended slabs flat surface of concrete finished rough surfaces of concrete not exceeding 200mm thick, complete all as specified and directed.
S&F mild steel bars conforming to Fe-290 (Gde E-165) 10mm dia and over, cut to length, bent to shape required,including binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
Taking down chowkhats or frames with shutter (without taking off shutter from the frame) exc 1.50 sqm but n exc 4 sqm in each complete all as specified and directed.
Taking down, Shutters of any description exc 1 but n exc 2 sq. m each, etc complete all as specified and directed.
Refixing in same opening shutters of any description n exc 1sq.m each includes taking down, easing and adjusting and also refixing builders hardware as required including renewal of unserviceable screws, etc complete all as specified and directed.
M&L 35mm thick 2nd class hard wood Glazed and skelton shutter, open rebated and prepared to receive glass, gauge etc. (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc. complete all as specified and directed.
S & F of 32 mm thick factory made flush shutter, solid core construction with block board core and plywood face panels commercial type on both faces one face is covered with decorative face veneer with lipping/frame to match fixed with complete all as specified and directed.
M/L for applying two coats of synthetic enamel paint over a coat of pink primer including preparation of new wooden or wood based surfaces over 10cm width or girth etc complete all as specified and directed.
M/L for prepration of old surface of wood or wood based materials of any descriptions applying one coats of synthetic enamel paint over 10cm width or girth etc complete all as specified and directed.
S/F of factory made solid PVC door frame (chowkhat) of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. squre tube, S&F in opening as per specification and drawing complete all as specified and directed.
S&F 18mm to 20mm thick solid factory made PVC board for cup board /cabinate shutter with one side 1mm thick printed pvc sheet other side plain pvc sheet suitable fixed with &including suitable pvc frame, matching colured beading to cover all edges & screwed portion of frame, Magnetic catcher as per specification & drawing complete all as specified & directed.
S/F of factory made solid PVC moulded door shutter 28 to 30mm thick (stiles) with 2,4 or 6 raised panel design with 2 mm thick Moulded PVC sheet on the font face on back face S&F in frame as per specification and drawing complete all as specified and directed.
S&F 100mm size mild steel butt hinges medium weight cold rolled complete all as specified and directed.
S&F 150 mm long extruded aluminium alloy handle complete all as specified and directed.
S&F 150mm long Anodised Aluminium tower bolt all as specified and directed.
S&F 300mm long Aluminium alloy, anodised, sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast- aluminium alloy all as specified and as directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden/metal frames glazed with putty or fixed with beads including punching or drilling out old glazing pins/spring clips etc complete all as specified and directed.
S&F for 3 mm thick,Sheet glass,ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane, etc completed all as specified.
S&F Galvanised mild steel wire cloth 0.63 mm nominal dia and average width of aperture 1.40 mm complete all as specified and directed.
Demolition and breaking up drain/rain water pipe of any type and size, set in cement mortar or complete all as specified and directed.
S& F 75mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed.
S&F 75mm dia PVC (SWR) bends any radius complete all as specified and as directed.
S&F 75mm PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and as directed.
M&L 75mm dia PVC (SWR) floor trap, plain with gratingincl jointing with solvent cement complete all as specified and as directed.
S&F 110mm PVC (SWR) pipes(ISI Marked) single socketed in any length with rubber ring joints laid in trenches or in floors, complete all as specified and directed.
S&F in repair 110mm PVC(SWR) bends any radius complete all as specified and directed..
S&F 110mm PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and as directed.
M&L RCC 1:2:4 type B1 using 20 mm graded aggregate as in slab, shelves etc.all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
S&F Framed work as in door or gates of angle or other section with guest plates, rails, braces, etc,. Compleete drilled for fixing of steel sheeting or other covring . Doors etc to be prepared for handing or sliding with and including either hooks and hinges or steel hangoing foor fitting (exlusive of steel, sheeting or other covering, running rails and guides ) and hanging alos fastening and fixing complete all as specified and directed
M&L for prepration of New surface of steel surfaces and steel based materials of any description over 10cm grith or width and applying two coat of synthetic enamel paint complete all as specified and directed.
S&F in repairs vitreous china wash hand basin, white, flat, back size 550x 400mm, incl cutting for and pinning in ends of brackets or erecting stan complete all as specified
Taking down old steel tubing & connection including cleaning for refixing for 15mm bore pipe complete all as specified and directed.
ditto but 20 mm bore complete all as specified and directed.
S&F 15mm bore galvanized iron tubes medium grade with all fitting and fixed complete to walls, ceiling or laid in floor complete all as specified.
ditto but for 20 mm bore tube complete all as specified and directed.
S&F in repairs 20mm bore stop valve, cast copper alloy screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
S&F in repair 15mm bore stop valve, cast copper alloy screwed down high pressure with crutch or butterfly handle chromium plated fancy type long shank and cup(concealed type), screwed both ends for iron pipe or for unions complete all as specified and directed.
S& F in repair soap dish, Stainless steel of approved pattern complete all as specified and directed.
S&F (ABS body) shower rose 125 mm dia Round shape flow with Rubit Cleaning system complete all as specified and directed.
S&F PVC conneciton 450 mm long, 15mm size with PTMT nuts complete all as specified and directed.
S&F vitreous chiana wash down water closet (Pedested patern ) white incl fixing bolt, plastic water closet seat cover black/white closed pattern with flat bottom and cover and mild steel chromimum plated hinging device, fixed in repairs and incl 32mm dia waste pipe complete all as specified and directed.
S&F in repairs PVC white low level flushing cistern 10 ltr capacity with all fittings syphonic action type with inlet ball valve and float, handle with & including bracket and PVC flush pipe 32 mm bore complete all as specified and directed
S&F in repair Tolilet paper holder, vitreous China colour box type to walls with CP (CP) brass screws complete all as specified and directed.
S&F in repair (ABS Body) health fauset with 1.20 meter long flexible PVC tube fancy type with necessary brass nuts & rubber washers cover with chromium plated spring complete all as specified and directed.
S&F 600 mm long 20mm dia brass chromium plated tubular towel rails,complete all as specified and directed.
S&F 150 mm dia towel ring complete all as specified and directed.
S&F 100 mm dia CP brass granting round with hole complete all as specified.
S&F in repair for 5 mm thick sheet glass assembly fancy type 600 mm long and 120 mm wide with CP gurard and double railing and fixed with brass screw complete all as specified.
S&F in repairs depray rod 30 mm dia Aluminium fancy tuype powder coated wood finish including wooden rings, wooden knobs & wooden brackets complete all as specified and directed
S&F in repairs sinks made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm, etc complete all as specifed and directed.
S&F in repairs Stainless steel utencil plate rack size 600 mm x 600 mm x 250 mm ) using 0.8 mm thick sheet complete all as specified and as directed.
S&F 15 mm dia brass CP sink mixer with swivel sout wall mounted for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed.
S&F 15 mm dia brass CP wall mixer provision for over shower with 115 mm long bend piper & wall flange for miing hot & cold water screwed down for iron pipe and fixed omplete all as specified and directed.
S&F 15 mm dia brass CP central hole wash hand basin mixer w/o PUW with 450 mm SS flexible hose screwed down high pressure screwed for iron pipe completed all as specified and as directed.
S & F in repair for Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, but fancy type, chromium plated, Bore dia of pipe in 15 mm, etc complete all as specifed and directed.
S&F in repair 15 mm chromimum platated fancy type Bib taps,screwed down, screwed for iron pipe or for brass ferrule and fixed, Bore dia of pipe in 15 mm, etc complete all as specifed and directed.
S&F in repairs Mild steel 30 mm ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
S&F 75mm PVC(SWR) vent cowl complete all as specified and directed.
Cutting chases, brick walls, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills,sunshades, shelves, lintels, etc.; and cutting chases for concealed watertubing or concealed conduit wiring,etc., and making good, cutting not exc 10 cm girth etc.complete all as spd and directed.
Surface dressing n.exc (not exceeding) 15 cm deep and getting out soft / loose soil complete all as specified and directed
Excavation in trenches n.exc. 1.5m wide and n.exc. 1.5m in depth for foundation etc. or for shaft wells, manholes, piers holes etc. n.exc. 10 Sqm on plan 4 n.exc. 1.5m in depth & getting out in any type soil.
M&L for Cement concrete as in foundations filling and mass concrete type D2 1:4:8 using 40mm graded stone aggregate complete all as specified & directed.
M&L for brick work with sub class-‘B’ bricks straight or curved on plan exc. 6m mean radius built in CM 1:6.complete all as specified and directed.
M& L RCC M-25 designed mixed (20 mm graded stone aggregate) as Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M& L RCC M-25 designed mixed (20 mm graded stone aggregate) as in top/roof beams cantilevers bressumers lintels over 1.5 m span complete all as specified and directed etc.
M& L RCC M-25 designed mix (20 mm graded stone aggregate) as in column, pillars, piers, posts and struts etc complete all as specified and directed.
M& L RCC M-25 designed mix (20 mm graded stone aggregate) as in Slabs supported on walls, beams and columns in floors,roofs, landings, balconies, canopies, deck slabs and in shelves etc complete all as specified and directed etc.
M & L Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finsh surface of concrete etc complete all as specified and directed.
M & L Formwork to sides of pillers , posts struts, piers, columns and stanchions for roough finish of concrete etc complete all as specified and directed
M& L Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work;not exceeding 200mm thick complete all as specified and directed.
M&L for T.M.T. Bars 10mm dia and over cut to length bend to shape required incl cranking, bending spirally for hoping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc. complete all as specified & directed.
.-Ditto-; but 5mm dia and over upto and including 10mm dia in stirrups , spacers and binders.
M&L for rendering 15 mm thick (internal) on fair faces of concrete/ brick surface in cement mortar 1:4 finished fair and even on Wall and applying three coat of white wash on newly plastered surfaces including preparation of wall etc complete all as specified and directed.
M&L for rendering 10 mm thick on fair faces of concrete/ brick surface in cement mortar 1:3 finished fair and even on ceilling & and applying three coat of white wash after prepration of newly plastered surfaces etc complete all as specified and directed.
M&L for rendering 15 mm thick on fair faces of concrete/ brick surface in cement mortar 1:6 finished fair and even as in wall and applying two coat of cement base paint over alkali priming paint after prepration of newly plastered surfaces of walls including ncecessary scaffolding complete all as specified and directed.
Returning, filling in, incl spreading leveling, watering & well ramming in layers not exc. 25cm of soft/loose soil.
Removing exc. Materials exc 500 mtr but up to total distance nexc 1.5 km & depositing where directed at level n. exc. 1.5m above the starting point.
M&L 150 mm thick Hard core of broken stone boulder n exc 63 mm agg as in foundation filling complete all as specified and directed.
M&L for 100 mm thick Plain Cement concrete type D-2,1:4:8 (40mm graded aggregate) as in sub base / Base course of floor / ramp complete all as specified and directed.
M&L for 50 mm thick Plain Cement concrete type B-2,1:2:4 (40mm graded aggregate) as in sub base / Base course of floor / ramp with 22 mm wide Glass dividing strips, 3 mm thick etc complete all as specified and directed.
Supply only Integral waterproofing compound complete all as specified and directed.
M&L for Providing water proofing treatment over cleaned roof surface with super thermo APP modified water proofing memberane comprising of the following for Non approachable roofs:- (a) Cleaning of plastered roof surfaces and applying a coat of bitumen primer @ 0.30 kg/Sqm on top of dry surface of finished cement mortar plaster. (b) One coat of hot blown bitumen of grade 85/25 @ 1.2kg /sqm shall be applied over APP Membrane. (c) One layer of APP based polymeric membrance minimum weighing 3 Kg/ Sqm & minimum 3 mm thickness reinforced with polyster non woven fabric (wt not less than 150 gms/ sqm) land on primed surface by forced application complete all as specified. with lap of 100 mm and the over lap shall be sealed by flame
Taking down of carefully unserviceable Aluminium/copper point wiring (light, fan socket or power) complete with fitting such as switches, ceiling rose lamp holder, sockets, fan regulators, SK/FTL light fittings etc removing materials for store for keeping in safe custody or for taking credit (credit for above items should be taken as per conditions separately) and making good disturbed surfaces of walls, floors etc as specified and directed.
M&L for point wiring with single core PVC insulated unsheathed 1100 volt grade FRLS-IS 694 cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI marked not less than 20mm dia, concealed conduit wiring in walls and surface with GI saddles GI screws, rawal plugs in ceiling or roof if not possible including Tee, Junction boxes and provision of flush metal boxes, inner and outer plate suitable for modular switch, socket and fan regulator as per site requirement and drawing continuous earth wire with and including PVC insulated unsheathed 1100 Volts grade FRLS-IS 694 cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) and connected to main earth dolly complete all as specified for one light/Fan point controlled by one Switch.
All as per Srl item No 102 above for point wiring for 5 pin switch socket outlet, 5/6 Amps on same board with other switches omplete all as specified and directed.
All as per Srl item No 102 above for point wiring for 5 pin switch socket outlet, 5/6 Amps on independent board.omplete all as specified and directed.
All as per item No 102 above for one power point 3 pin 15 Amps socket out let PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 2.5 Sq mm (Nominal area) including earth wire PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 1.5 Sq mm (Nominal area)cable common connected to earth dolly, all as specified for one 3 pin 15 amps socket outlet point controlled by one switch complete.
All as per item No 102 above for one power point 3 pin 15 Amps socket out let PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 4 Sq mm (Nominal area) including earth wire PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 2.5 Sq mm (Nominal area)cable common connected to earth dolly, all as specified for one 3 pin 15 amps socket outlet point controlled by one switch complete.
All as per Srl item No 102 above but point wiring for one bell/buzzer point controlled by one push button on the same board with other switches or independent omplete all as specified and directed. Note for item 102 to 107 here in before : (i) The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillars etc. for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing surface. The portion of point wiring at RCC Columns/Beams/Ceilings shall be in surface conduit of suitable size fixed on surface with using PVC rawl plugs . (ii) Rate for modular metal flush boxes ,inner and outer plate with frames are deemed to be included in the quoted rate by contractor for above items. (iii) Fittings like Modular switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A'. (iv) The size of conduits shall be determined on permissible No. of runs of wires as specified in SSR Part-I (2009) clause 19.125 (B). However minimum size of conduit shall be 20mm dia (Medium grade (v) Make of cable : Finolex /Havells/ Poly cab as approved by GE.(vi) Make of PVC conduit & fittings : AKG / Asian /Plaza/Jindal /Avon/Finolex/National /Kalinga as approved by GE.
S&F Modular switch piano single pole one way 6 amp complete. Make -Legrand / Anchor Penta / Crabtree as approved.
S&F Modular switch piano single pole one way 16 amp complete. Make - Legrand / Anchor Penta / Crabtree as approved.
S&F Modular bell push, 6 amp 240 volts complete. Make - Legrand / Anchor Penta / Crabtree as approved.
S&F door bell, AC, 240 volts, single pole complete. Make - Legrand / Anchor Penta / Crabtree as approved.
S&F Modular socket outlet 2/3 pin combined 2 module 6/16 amp complete. Make -Legrand / Anchor Penta / Crabtree as approved.
S&F Modular socket outlet 2/3 pin combined 2 module 6 amp complete. Make -Legrand / Anchor Penta / Crabtree as approved.
S&F ceiling rose 3 plates polycarbonate, isolated body complete. Make - Legrand / Anchor Penta / Crabtree as approved.
S&F Angle holder, insulated polycabonate body with back plate suitable for batten fittings complete with One number LED lamp 9/10 Watt. Make of holder - Legrand / Anchor Penta / Crabtree and Make of LED - Havells / Philips/ C&S as approved.
S&F modular fan step regulator 120 W 2 module complete. Make: Legrand / Anchor Penta / Standard/Crabtree as approved.
S&F in replacement of UNSV fluorescent tube light fitting batten with universal batten fitting suitable for single T8 LED lamps complete all as specified and directed. Make: DMLN1LT8-16 of C&G or euivalent in Philips/ Havells
S&F in replacement of UNSV fluorescent tube light with LED tube light 16 Watt T8 double sided connection with built-in driver, THD not more than 10% all as per C&G cat ref no LGT8-16-865-2 or equivalent in philips/Havells as approved.
S&F in replacement of UNSV LED mirror light fitting, 10 watts, 1000 lumens 6500K comprises of aluminium extruded channel, frosted diffuser, integrated electronic driver, IP 20 protection and all accessories pre- wired including connecting to mains complete all as directed. Make- LDL-10-CDL of C&G or equivalent in Havells/Phillips
S&F in replacement of UNSV bulkhead fitting with integrated LED bulk head fitting 600 lumens, 6000 K comprises of pressure die cast housing, acrylic diffuser and frame IP 65 protection, IK-07 etc including connection complete all as directed.Make- LBHP-10-CDL of C&G or equivalent in Havells/Phillips as approved.
S&F in replacement of UNSN Decorative, Wall mounting champagne gold finish fixture with plastic body along with 9 W LED lamp B22 base as per Havells cat ref no. LHFOECE1TZ1O014 or equivalent in Philips/C&S as approved.
M&L in replacement UNSV of sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable of size 6 Sqmm of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (Medium grade) of suitable dia not less than 25 mm dia with standard accessories along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 4 Sqmm as earth continuity conductor complete all as specified and directed.
M&L in replacement UNSV of sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable of size 4 Sqmm of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (Medium grade) of suitable dia not less than 20 mm dia with standard accessories along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 2.50 Sqmm as earth continuity conductor complete all as specified and directed. Notes for item No. 21 & 22: (i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit. (ii) The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillars etc. for concealing the conduits to required depth & making good the disturbed surface in cement sand mortar 1:4 including finishing the surface to match with the existing surface. The portion of sub main wiring at ceiling/RCC surfaces shall be in surface conduit of suitable size fixed on ceiling/RCC surfaces with using PVC rawl plugs) (iii) Make of cable : Plaza /Finolex /Havells/Shalabh/ Polycab/HPL/L&Tas approved by GE. (iv) Make of PVC conduit & fittings : AKG / Asian /Plaza/Jindal /Avon/Finolex/National /Kalinga as approved by GE. )
S&F in replacement of UNSV MCB distribution board SPN, 240 volts, 12 ways ,powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 42- IK-09 with metal double door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required with following ratings & ways:- Note: (i) MCB’s /Isolators etc. shall be measured and paid for separately under appropriate item of Sch ‘A’. Make: Legrand/Havells/L&T/Schneider/Indoasian as approved Note for Item No.23 (i) Fittings like MCB’s /Isolators etc. shall be measured and paid for separately under appropriate item of Sch ‘A’. (ii) -Sheet steel enclosure to be fixed flush to wall by cutting niche & make good to the disturbed wall surface as per existing (iii) Rate for Incomer MCCB is deemed to be included under above item.
S & F in replacement of unserviceable MCB SPN 240 volts 'C' Curve suitable for fixing in MCB DB of capacity 6 to 32 amps complete all as specified and directed.Make - IndoAsian cat ref no 811144/46/48/49/50/51 or equivalent in Hager or Schneider as approved.
S & F in replacement of unserviceable MCB SP 240 volts 'C' Curve suitable for fixing in DB of capacity 6 to 32 Amps complete, all as specified.Make -IndoAsian cat ref no 811122/24/26/27/28/29 or equivalent in Hager or Schneider as approved.
M/S WASEEM KHAN CONTRACTOR
Gaur Construction Co
M/S DHYANI CONSTRUCTION CO.
sidh builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .