Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 CrAccepted-AOC | ₹1.8 Cr Quoted ₹1.9 Cr | L1 | Accepted-AOC L1 BIDDER |
| 2 | L2₹1.9 Cr+₹3.5 L (1.87%)Rejected-Finance BINDA JAYANTI BUILDING 31 SEVOKE ROAD SILIGURI PIN 734001 DIST DARJEELING | SILIGURI | DARJEELING | WEST BENGAL | 734001 | ₹1.9 Cr+₹3.5 L (1.87%) | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| 3 | L3₹1.9 Cr+₹8.6 L (4.64%)Rejected-Finance 100 GIRISH GHOSH ROAD DONBOSCO LILUAH HOWRAH WEST BENGAL 711202 | HOWRAH | WEST BENGAL | 711202 | ₹1.9 Cr+₹8.6 L (4.64%) | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| 4 | L4₹2.0 Cr+₹9.4 L (5.08%)Rejected-Finance PO KETEKIBARI DISTT SONITPUR TEZPUR ASSAM 784001 | SONITPUR | ASSAM | 784001 | ₹2.0 Cr+₹9.4 L (5.08%) | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| 5 | L5₹2.0 Cr+₹11.0 L (5.94%)Rejected-Finance BEHIND CENTRAL BANK OF INDIA PO KADAMTALA DIST DARJEELING PIN 734011 WB | DARJEELING | WEST BENGAL | 734011 | ₹2.0 Cr+₹11.0 L (5.94%) | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹1.9 Cr
EMD Value
₹2.7 L
Closing Date
30 Aug 2022, 6:00 pmClosed
CWE BINNAGURI
HQ CWE BINNAGURI
ADDN / ALTN AND SPECIAL REPAIR TO OTM-06 ACCN AT BINNAGURI MILITARY STATION UNDER GE (NORTH) BINNAGURI
2022_MES_541440_1
8010/BIN(N) 10 of 2022-23
Open Tender
Civil Works
Item Rate
365 days
BINNAGURI MIL STATION
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹1,000
GE (N) BINNAGURI
₹2.7 L
Yes
18 Oct 2022
27 Jul 2022
31 Aug 2022
27 Jul 2022
30 Aug 2022
24 Aug 2022
Amount
Taking down tar felt with cement plaster from roof surfaces and lowering and removing the same to a distance exc. 50m and n. exc. 100m incl roughening of old concrete surface of roof by wire brushing and cleaning the surface to remove all loose dust etc.. complete all as specified and as directed .
M&L for 10mm thick screed bed or bedding layer in cement mortar (1:4) mixed with WPC over existing roof surfaces finished even and fair without using extra cement complete all as specified and as directed.
M&L for PCC (1:2:4) type B-1 (using 20mm graded mechanically crushed stone aggregate) as in roof kerbs, padding over RCC roof slab (to maintain proper slope on roof of average 40 mm thick) etc. slightly rounded or chamfered on edges, mixed with water proofing compound 200 ml per bag of cement or as per manufacturer instructions finished even and smooth on exposed concrete surface without using extra cement all complete as specified and as directed. Note: Water proofing compound shall be measured and paid separately under relevant item of this schedule.
M&L for waterproofing Coating with polyurethane-based water proofing liquid membrane to be applied by brush with multi coats with minimum dry film thickness of 1mm and shall be cured by reaction with atmospheric moisture to give a tough elastomeric waterproof membrane complete all as specified and as directed. Note: The above treatment will be carried out by authorised applicator of approved firm/ company.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified.
M&L for non skid coloured joint free ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.11 Sqm but n. exc. 0.18 Sqm, in floors etc. set and jointed in neat cement slurry over 15mm thick screed bed or bedding layer in cement mortar (1:6) as in floor and pointed in white or coloured cement to match as in floor complete all as specified and directed.
M&L for glazed ceramic coloured tiles 450 x 300 x 6-7 mm thick on vertical surface such as skirting, dado etc.. set and jointed in cement slurry and pointed in white or coloured cement to match with shade of tiles laid over and including 10mm thick rendering in Cement mortar (1:4) complete all as specified and as directed.
Roughening of surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc.. complete all as directed.
M&L for machine cut kota stone slab flooring 20-25mm thick, for staircase steps (treads) in single piece (of length not more than 1200mm), laid over & including 15mm thick (average thickness) cement mortar (1:6) screed bed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including provn of two Nos 3x3 mm grooves at tread of each step complete all as specified and as directed.
M&L for machine cut kota stone slab 15-20mm thick on vertical surfaces like riser of steps, skirting, in single piece (of length not more than 1200mm) over & including 15mm thick (average thickness) cement mortar (1:4) screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing (mirror finish), complete all as specified and as directed.
M&L for machine cut kota stone slab flooring 20-25mm thick over 15mm thick cement screed bed using cement mortar (1:6) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing (mirror finish) complete all as specified and as directed.
M&L for machine cut kota stone as in riser / skirting 15-20mm thick over 15mm thick rendering using cement mortar (1:4) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing (mirror finish) complete all as specified and as directed.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry over 15mm thick screed bed or bedding layer in cement mortar (1:6) as in floor and pointed in white or coloured cement to match as in floor complete all as specified and directed.complete all as specified and as directed.
M&L for 75 mm thick cement concrete type C-2 (1:3:6) (using 40 mm graded stone aggregate) as in sub base finished even & rough to receive tiles complete all as specified and as directed.
M&L for 25 mm thick cement concrete type type B-1 (1:2:4) (using 20mm graded stone aggregate) as in base to receive the screed bed complete all as specified and as directed.
M&L for water proofing treatment to sunken floor complete all as specified and as directed.
Taking down cement plaster on wall of any description incl racking out joints, hacking for key, scrubbing down with water etc.. complete all as specified and directed.
M&L for 20 mm thick plaster of cement mortar (1:4) rendering on fair faces of brick work in two layers (10mm & 10mm) mixed with water proofing compound in top layer 200 ml per beg of cement or as per manufacturer's instructions finishing the surface fair and even (without using extra cement) complete all as specified and as directed. Note: Water proofing compound shall be measured and paid separately under relevant item of this schedule.
M&L for rendering 5 mm thick cement plaster on ceiling/ facia/ chhaja using cement mortar (1:3) finished even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 15 mm thick cement plaster on other than fair surfaces of brick work in cement mortar (1:6) finished even & fair without using extra cement all complete as specified and as directed .
Supply only liquid water proofing compound conforming to IS: 2645 - 1975 complete all as specified and as directed.
M&L for complete removal of existing treatment of wall (Internal & external) and applying two coats of cement – based wall care putty including preparation of surface to receive finishes (primer, distemper, paint etc.) complete all as specified and as directed by the Engr-in-Charge and as per the manufacturer’s instructions. Note : Removal of existing treatment and application of wall care putty to be carried out mechanically by authorized applicator and as per the manufacturer’s instructions.
M&L for preparing of new plastered surfaces of wall (Internal & external) and applying two coats of cement based wall care putty including preparation of surface to receive finishes (primer, distemper, paint etc.) complete all as specified and as directed by the Engr-in-Charge and as per the manufacturer’s instructions. Note : Preparation of new plaster surface and application of wall care putty to be carried out mechanically by authorized applicator and as per the manufacturer’s instructions.
M&L for applying two coats acrylic-based distemper of shade as approved by GE over a coat of primer over finished putty surfaces of wall complete all as specified and as directed by the Engr-in-Charge and as per the manufacture's instructions. Note : 1. Application of new finished to be carried out mechanically by authorized applicator and as per the manufacturer’s instructions. Please refer Smart painting clause mentioned in Particular Specification. 2. Application of putty and preparation of surface to receive the distemper shall be measured and paid separately under relevant item of this schedule.
M&L for preparation of newly ceiling plastered surfaces and applying three coats of white wash as complete as specified and as directed
M&L for one coat of white wash on old plastered ceiling surface including brooming down or steel wire brushing or scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil including greasy spots complete all as specified and as directed.
Taking down Chowkats or frame exc. 1.5 Sqm but n. exc. 4 Sqm each without taking off shutters from the frame including fittings complete all as specified and as directed.
Taking down Chowkats or frame n. exc. 1.5 Sqm each without taking off shutters from the frame including fittings complete all as specified and as directed.
Taking down shutter of any description exc. 1 Sqm but n. exc. 2 Sqm each & refixing of shutter in same opening including easing , adjusting & renewal of unserviceable screws etc. complete all as specified and as directed.
S&F of pressed steel framed for door with one or more rebates including supply & fixing necessary lugs, hinges, lock strike plates, size of frame 125 X 60 mm, 1.60 mm thickness of sheet incl one shop coat of priming complete all as specified.
M&L for preparation of surfaces of wood and wood based materials, steel and iron work, new or old, of any description and girth, not otherwise described, and treated with tar or coal tar black paint to the treating ends of posts, backs of chowkats, etc. area tarred exc 0.10 Sqm but n. exc. 0.5 Sqm each complete all as specified and as directed.
S&F of factory made solid PVC door frame of size 50mm x 47mm made out of 5mm wood grain printed colour PVC sheet reinforced with 19x19mm MS square tube and 1.2 mm wall thickness complete all as specified and as directed.
S&F of factory made 35mm thick 2nd class hard wood gauged and skeleton shutter open rebated and prepared to received gauge etc. (without sash bars) for fly proof door shutter, edges of framing plain, chamfered or rounded, fitted with cut of any mitred beads for securing gauge etc. size of members of shutter as specified in SSR Part-I section 8 clause No. 8.24(a) and fitted to chowkats complete all as specified and as directed.
S&F of 30 mm thick flush shutters solid core construction with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed.
S&F of factory made solid panel PVC door shutter, 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails MS frame shall be covered with heat moulded wood grain printed colour PVC 'C' channel having a PVC sheet strip of 20 mm width struck inside with solvent cement for stile and woodgrain printed colour PVC sheets for top rail lock rail & bottom rail on either side and as gap insert for top rail & bottom rail; panelling of wood grain printed colour PVC sheet to be fitted in MS frame welded/ sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, suppling & fixing in the frame at site as per manufacturer's instruction, specification complete all as specified and as directed.
S&F of stainless steel butt hinges, medium weight cold rolled of size 100 mm complete all as specified and as directed.
S&F of 150 mm long extruded aluminium alloy handles, fabricated type, anodised complete all as specified and as directed.
S&F of 200mm aluminium anodised, barrel tower bolts of extruded section complete all as specified and as directed.
S&F of 300 mm Mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified .
Dismantling of steel window and ventilator of any description and size including grill/guard bar complete all as specified.
S&F of steel window with side hung shutters including projecting type hinges with steel handles steel peg stay fixing lugs complete with glazing bar 10 cm dovetailed or welded including one shop coat of zinc chromate primer compete all as specified and as directed.
S&F of steel window with side hung shutters including projecting type hinges with steel handles steel peg stay fixing lugs complete but without glazing bar 10 cm dovetailed or welded including one shop coat of zinc chromate primer compete all as specified and as directed.
S&F of steel ventilators, with top hung shutters, including hinges, steel peg stay etc. with glazing bars including one shop coat of zinc chromate primer complete all as specified and as directed.
M&L for mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings framework of water tanks and similar work conforming to Fe. 290 (Gde-E-165) including one shop coat of zinc chromate primer complete all as specified .
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified .
M&L for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc. complete, drilled for fixing of steel sheeting or other covering viz. doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging confirming to FE-290 (Gde E-165) including fastening and fixing complete all as specified and as directed.
M&L for cleaning & washing of pre-primed steel and Iron surface of any description, not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint (1st quality) complete all as specified and as directed.
M&L for preparation of new of previously untreated steel and Iron surface of any description, not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
M&L for preparation of new or previously undecorated wooden surface of any description, not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified.
M&L for preparation of old painted iron surface and applying one coat of synthetic enamel paint on steel surface of any description, not otherwise described over 10 cm width or girth complete all as specified and as directed.
M&L for preparation of old or previously undecorated wooden surface of any description, not otherwise described over 10 cm width or girth and applying one coats of synthetic enamel paint complete all as specified and as directed.
Hacking out old broken unserviceable glass panes (any thickness, size, quality or description) for metal frame including punching or drilling out old glazing pins/spring clips and providing & fixing new one complete all as specified and as directed.
S&F of 3 mm thick sheet glass, ordinary quality and glazing with oil putty in square n.exc 0.5 sqm in each pane complete all as directed.
S&F of frosted glass pin head type 3 mm thick in squares n.exc 0.50 Sqm in each pane complete all as specified and as directed.
M&L for PCC type C-1 (1:3:6) (using 20mm graded aggregates) as in bed block for fixing of hold fast, filling concrete in frame filling , gaps in between glazed & flyproof steel window, cills, railing up to 60 cm in height etc. including necessary form work as required all complete.
S&F of stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm complete all as specified.
S&F of in repair stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm complete all as specified.
Demolition of cement concrete (un-reinforced ) in ground floors and pavings n. exc 15 cm thickness (below or above ground level) all as specified and as directed.
M&L for PCC (1:3:6) type C-2 (using 40mm graded stone aggregates) 75 mm thick in plinth protection/footpath laid in panel and finished even and smooth w/o using extra cement complete including necessary formwork , providing Joints 12 mm wide to the full depth pf PCC shall be provided at every 3 meters and at every change of direction and shall be filled with mixture of Bitumen and sand 1:3 by weight complete all as specified and directed
Taking up or down steel tubing and connections, including cleaning for refixing or removal to store of 15 mm bore complete all as specified.
S&F of tubes, medium grade, 15mm bore, galvanised, with all fittings and fixed complete to wall and ceilings or laid in floors complete.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 for cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting not exceeding 10 cm girth in brick walls complete all as specified.
Taking up or down steel tubing and connections, including cleaning for refixing or removal to store of 20 mm bore complete all as specified.
S&F of tubes, medium grade, 20 mm bore, galvanised, with all fittings and fixed complete to wall and ceilings or laid in floors complete.
Dismantling water tank exc. 500 & n. exc. 1000 ltr capacity and removing to store all as specified.
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position including cleaning and removing all scale and dirt, etc. from tanks and from mouths of circulating pipes, etc. complete all as specified and as directed.
S&F of 1000 ltrs capacity rotational moulded polyethylene water storage tank, multi layered (cylindrical vertical with closed top) hoisted and fixed in positions all specified in SSR Part I, with ISI mark embossed complete all as specified and as directed.
S&F of ball valves of 20mm bore high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe & fixed (Minimum weight 20 gms-210 gms)
S&F of in repairs 15 mm dia Bib tap long body , brass CP with fancy type screwed down, screwed for iron pipe or for brass ferrule and fixed .
S&F of in repair 15 mm fancy type chromium plated bib tap brass short body with flange screwed down high pressure CP cast copper alloy with crutch or butterfly handles screwed down suitable for 15mm bore pipe or union complete all as specified and as directed.
S & F in repair concealed stop cock CP, cast copper alloy fancy type with long shank and cup for 15mm pipe complete all as specified.
S&F of in repairs of Chromium plated shower roses with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed.
S&F ceramic undercounter wash hand Basin Glossy finishes, size 22x16x8 inch size including CP waste coupling, PVC connection 450 mm long, waste pipe and removing the existing Basin, cutting for and pinning ends of brackets or erecting stand complete all as specified.
S&F of in repairs 15 mm bore pillar taps, capstan head, cast Copper alloy, chromium plated, screwed down high pressure with or without lettered ‘HOT’ or ‘COLD’ long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed.
S&F of in repairs, vitreous china squatting pan "Orissa" pattern size 580x440mm white with integral foot rests(excluding flushing cistern and flush pipe) with 'P' or 'S" trap front or back inlet etc. including connection to trap and flushing pipe and provision of lime concrete bedding complete all as specified and as directed in repairs including demolition of existing one.
S&F of in repairs, Vitreous china wash down water closet pan (Pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe), P or S trap, all as specified and as directed.
S&F of PVC water closet seat cover , white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified.
S&F of in repair 10 ltr capacity PVC flushing cistern low level white colour incl PVC connection 450 mm long, PVC flush pipe of reqd length etc. complete all as specified and directed
S&F of in repair vitreous china half stall type urinal with grating and union for discharge pipe incl connecting pipe & waste pipe with coupling, Urinal Spreader complete all as specified and as directed.
S&F of in repair 15 mm dia brass chromium plated angle cock with flange complete all as specified.
S&F in repair Towel rail 450mm long of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (Minimum weight 170 gms) complete all as specified.
S&F in repair Stainless steel Towel ring including Chromium plated brass screws and wooden/ plastic cleats complete all as specified.
S&F of Polycarbonate wall mounted soap dish fixed to plugs with chromium plated brass screws complete all as specified.
S&F of CP health faucet with 1.2 meter tube and hook complete all as specified.
S&F of Aluminium Hat pegs, solid body, 125mm to 175 mm all as specified and as directed.
M&L for 18 to 20 mm thick granite (of any type) work (table rubbed and polished) in steps, Jambs, pillars, window cills, cooking platforms, corner shelf, Flat shelf and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite and including 15 mm thick cement plaster (1:6) including rounding the exposed surfaces of granite complete all as specified and as directed.
S&F of PVC (SWR) floor trap 75mm/ 100mm, plain with grating including jointing with solvent cement complete all as specified.
Taking down old unserviceable PVC pipe including all fittings complete all as specified.
S&F of 110 mm dia PVC SWR pipes single socketed in any length with rubber ring joints, fixed to wall complete all as specified.
S&F of 75/110 mm dia PVC pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors
S&F of 110mm dia PVC SWR bends of any radius with access door complete all as specified.
S&F of 110 mm dia PVC (SWR) junction single 'T' equal or unequal with access door complete all as specified and as directed.
S&F of 110mm dia PVC (SWR) branch piece, single 'Y' equal or unequal complete all as specified and as directed.
Demolition of reinforced concrete of any description and in any position not otherwise specifically provided for complete all as specified .
M&L for RCC type B1 (1:2:4) using 20 mm graded aggregate in Fins, fascias, louvres, parapets, and railings ,manhole cover, newels, balustrade, beam, column, roof, landing etc. & the like
Formwork to fins, louvers, fascia, column, beam, slab, roof, railing etc. rough finished surfaces of concrete flat complete all as specified.
M&L for Mild steel TMT bars 5mm dia and over up to and including 10mm dia in stirrups, spacers and binders and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
S&F Mild steel TMT bar 10mm dia and over in manholes / rungs/ beam/ column, cut to length, bent to shape required, and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
S&F of Welded steel wire fabric of weight n.exc 4 kg per Sqm supplied and fixed complete to steel members all as specified and directed.
S&F of designer profile pre-painted galvalume aluminium zinc coating GI based corrugated/semi corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified.
S&F of pre-painted galvalume aluminium zinc coating GI Based plain steel sheet 0.50 mm thick of any colour having tensile strength 550 Mpa as in ridge fixed with self tapping screw complete all as specified.
S & F for Steel work in tubular trusses including special shaped washer etc.. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 and painted one shop coat of zinc chromate primer paint (including preparation of surface) at Contractor’s workshop before fabrication complete all as specified.
Cutting holes in brick walls built in cement mortar for inserting hold fasts & making good dismantled portion in CM 1:3 or cement concrete 1:2:4 type B-1, depth of embedded portion of hold fasts or lugs measured from the face of the jamb into the wall exc half brick but n.exc one brick complete all as specified and as directed.
Cutting grooves in brick wall, 75 mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 all as specified and as directed.
Demolition of brick work built in cement mortar including all quions, arches, pillars etc. complete all as specified and as directed.
M&L for burnt brick works with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified.
M&L for brick work with using fly ash bricks, straight or curved on plan to any radius laid in half brick thick walls, built in cement mortar 1:4 complete all as specified & as directed.
M&L for burnt brick works with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:4 as manhole complete all as specified.
M&L for 15mm thick rendering in cement mortar (1:3) on fair faces of brick walls or concrete surfaces in mixed with water proofing compound by weight of cement or as per manufacturer instructions, finished even & smooth using extra cement all complete as specified and as directed. Note: WPC shall be measured and paid under relevant item of this schedule.
M&L for Cement concrete type C-2 (1:3:6) (using 40 mm graded aggregate) in surface channels and drains complete all as specified.
Excavation in trenches n.exc 1.50m wide and n.exc 1.50 m in depth for foundation or for laying of sewage line, manholes, pier holes etc. and getting out in soft/loose soil complete all as specified and as directed
Returning, filling of soft/loose soil in, including spreading, levelling , watering and well ramming in layers not exc 25 cm complete all as specified.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified.
Demolition and breaking up drain pipes 150 mm bore (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified.
M&L for 150 mm thick concrete bed to drain pipe (150 mm bore) with PCC (1:3:6) type C2 using 40mm graded stone aggregate including packing under and haunching against the sides of pipe after they are laid jointed and tested complete all as specified and as directed.
M&L for 150 mm outer dia SWR Pipes laid in trenches and jointed all as specified and as directed.
M&L for PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified.
M&L for PCC 1:2:4 type B-1 ,(using 20 mm graded stone aggregate) as. in coping /benching to sides of foot path finished fair and even etc. complete all as specified and directed.
M&L for pre-cast RCC(1:2:4) type B-1 with using 20 mm graded stone aggregates as in manhole/gully trap cover slab, set in cement mortar (1:4) complete all as specified. Note : Reinforcement shall be measured and paid separately.
S&F of 0.56 mm thick Plain, Aluminium sheeting, Alloy 31000 H4 in crumple Joint (length and girth as fixed) complete all as specified and as directed.
M&L for Post construction ATT along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre or as per manufacturer's instructions including drilling and plugging holes etc. in apron complete all as specified and as directed.
M&L for Post construction ATT of soil under existing floors using emulsion @ one litre per hole or as per manufacturer's instructions, 300mm apart including drilling and plugging 12mm dia holes with cement mortar (1:2) to match the existing floors complete all as specified and as directed.
M&L for 75 mm thick cement concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in path /steps laid with and incl use and waste of form work and finishing the surface even and rough to receive the topping layer or tiling complete .
M&L for fine aggregate (sand) spreading and levelling in layer n exc 50mm thick under paver block for cushioning complete.
M&L for coloured machine pressed precast concrete interlocking paver block with Grey cement and pigment any shape and size conforming to IS 15658-2006 of 60 mm thickness M-35 Grade.
M&L for Post construction ATT at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole or as per manufacturer's instructions by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same complete all as specified and as directed.
Removing & Hacking of existing deteriorated damaged & loose concrete from the external surface carefully by low impact high frequency hammer or by including cleaning the surface by air jet etc. complete and also without damaging the existing structure. Note: The rate shall also include disposal of waste/ rubble/ malwa from site outside MD land up to as directed by Engr-in-Charge along with lead and lift if any including standard steel scaffolding up to a height of 7M.
Removing the loose scale of corrosion etc. from the exposed reinforcement and cleaning the corroded reinforcement by wire brush followed by cleaning with air blower/ water jet. and finally cleaning the rusted reinforcement/ metal (iron Base) by chemical rust remover, cleaning and etc. hing agent with brush for complete wetting of rusted metal surface and allowed to react it for 16-24 hours. After 24 hours, a white layer will appear which will protect further corrosion of metal/ steel for about 5-7 days. Before applying protective coating, the surface should be wire brushed and thoroughly cleaned for dust with dry cloth. The work to be done as per technical specification and also as per manufacturer's recommendation and also as per direction of Engr-in-Charge. Note: 1. The rate inclusive of labours, material, tools etc. complete in cluding standard steel scaffolding up to a height of 7 M. 2. The above treatment will be done in presence of manufacturer's authorised person and also by manufacturer's skilled labour.
M&L for surface cleaning and application of two coats of two component epoxy Zinc rich primer coat on steel surface/ reinforcement as per manufacturer's recommendation and as per technical specification and also as per the direction of Engr-in-Charge. Note: 1. The rate inclusive of labours, material, tools etc. complete in cluding standard steel scaffolding up to a height of 7 M. 2. The above treatment will be done in presence of manufacturer's authorised person and also by manufacturer's skilled labour.
Providing and fixing shear connectors of 10 mm dia by drilling 12 mm dia holes on the concrete surface to a depth of 100 mm using a rotary cum hammering drilling machine as per specification and thoroughly cleaning the hole using compressed air and water jet and anchoring with pure Epoxy resin based anchoring grout solution. Note: 1. The rate inclusive of labours, material, tools etc. complete in cluding standard steel scaffolding up to a height of 7 M. 2. The above treatment will be done in presence of manufacturer's authorised person and also by manufacturer's skilled labour.
Identifying the cracks and construction joints, honeycomb areas, shall be chased open into ‘U’ groove shape and sealed with High strength, abrasion-resistance epoxy reinstatement mortar including providing and fixing 6-8mm dia. nozzle along the joints and honeycomb areas after proper surface preparation and injection of epoxy resin grout through the nozzle till the refusal of the grouting materials. Note: 1. The rate inclusive of labours, material, tools etc. complete. 2. The above treatment will be done in presence of manufacturer's authorised person and also by manufacturer's skilled labour.
M&L for providing and applying structural grade long pot life, Two Component epoxy resin concrete bonding agent prior to building up of section with any type of mortar/ concrete to ensured bond between old concrete and new concrete by brushing application as per manufacturer instruction and also as per technical specification and also as directed by Engr-in-Charge. Note: 1. The rate inclusive of labours, material, tools etc. complete. 2. The above treatment will be done in presence of manufacturer's authorised person and also by manufacturer's skilled labour.
M&L for 25 mm thick (Avg Thickness) Guniting concrete surface using mechanical means with single component, shrinkage controlled, polymer modified, fiber reinforced structure grade cementitious repair mortar having compressive strength of 45 N/sqmm, flexural strength of 7 N/sqmm and tensile strength of 2.5 N/sqmm at 28 days all as per the direction of Engr-in-Charge. Note: 1. The rate inclusive of labours, material, tools etc. complete in cluding standard steel scaffolding up to a height of 7 M. 2. The above treatment will be done in presence of manufacturer's authorised person and also by manufacturer's skilled labour.
M&L for providing and laying of ready to use non shrink, cementitious free flow micro concrete up to required thickness at designated areas to the prepared slurry tight shuttering with proper shear connection and bonding agent where ever necessary. Then applying fluid single component, cement based, micro-concrete repair material as per manufacturer's instructions. The micro concrete shall contain no metallic aggregates, or chlorides and shall be shrinkage compensated in the plastic state. The micro concrete should achieve a compressive strength of 50 N/mm2 after 28 days at 30° C as per BS 4551-80. The unrestrained expansion shall be between 1- 4% as per ASTM C827-1987. Again as per BS 4551-80 the flexural strength shall not be less than 5 N/mm2 @ 28 days. The micro concrete shall have a coefficient of thermal expansion 10-12 X 10-6/°C & Thermal conductivity 1.5 W/m°C The mixed density of micro concrete shall exceed 2100-2200 kg/m3 at 27ºC. Note: The above treatment will be done in presence of manufacturer's authorised person and also by manufacturer's skilled labour.
Chase opening the Construction Joints by providing “U ” groove, removing the dust and clean the designated area fill the prepared surface using polymer modified bonding agent completely as per the manufacturer’s instructions. Drilling holes of dia 18mm maximum up to Half of the Depth of the Wall. Fix the PVC Nozzles of dia 15mm. Injecting cementitious Grout under pressure using grout pump to fill all possible pores. Note: The above treatment will be done in presence of manufacturer's authorised person and also by manufacturer's skilled labour.
Surface Preparation of Concrete Surface to be treated. The surface shall be free from oil residues demoulding agents curing compounds, grout holes and protrusion. In case of distressed Structure, the concrete surfaces to be warped shall be structurally repaired prior to treatment. Corrosion induced damages shall be repaired with micro comcrete including necessary structural damages and be repaired by using epoxy grouting. All depression, imperfection etc. shall be repaired by using epoxy putty, mortar etc. complete all as specified and as directed.
Priming should be carryout using carbon fibre composite wrapping system. After proper mixing of the component the application shall be carried out using a brush and allowed for drying for about 24 hrs before application of saturant a min. thickness of 100 micron should be maintained during application Saturant Application: After proper mixing of the component the application should be carried out using a brush and allow for drying for about 24 hrs before application of saturant over the tack free primer. The wet film thickness shall be maintained @ of 250 microns . One more coat of saturant is applied after the application of the carbon fabric at 250 microns complete as per manufacturer's instructions.
The carbon fibre fabric shall be cut to required size and then paste first by gloved hand on the saturant applied area and than with a stiff spatula or a surface roller to remove air bubbles complete as per manufacturer's instructions.
M&L for preparing new Plastered surfaces of walls and M&L for applying two coats of acrylic smooth exterior anti-fungal paint of shade as approved by GE over a coat of primer over finished putty surfaces of wall complete all as specified and as directed by the Engr-in-Charge and as per the manufacturer’s instruction. Note : for Item No. 01 & 2 : 1. Application of new finishes to be carried out mechanically by authorized applicator and as per the manufacturer’s instruction. 2. Application of putty and preparation of surface to receive the paint shall be measured and paid separately under relevant item of this schedule.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed.
M&L for point wiring complete for one power point for one metal plug & socket for geyser & AC point on independent board with 4.0 sqmm multistranded copper conductor single core PVC insulated unsheathed FR LS cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non metallic rigid PVC medium grade conduit not less than 20mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc. including provision of 4.00 sqmm PVC insulated multistranded unsheathed copper conductor cable FRLS (ISI marked) as earth continuity conductor connected to common earth dolly, including cutting chases of existing wall for conduits and fixing for metal plug and socket boxes and making good to the disturbed surface of wall/floor and matching with existing specifications. Connections of cable with MCBs or bus bar shall be done through proper size copper/brass thimbles.
M&L for point wiring complete with 1.5 Sqmm single core PVC insulated unsheathed FR-LS cable 1100 volts grade (ISI marked) with multistranded copper conductor with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc. including provision of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LS (ISI marked) with proper colour coding as earth continuity conductor connected to common earth dolly , modular sheet steel sunken terminal box of appropriate size suitable for modular switch/ fittings concealed in walls, with modular back plate, top cover fixed flush to wall for housing switches, socket outlets, fan regulators etc. duly earthed including cutting chases of existing wall for conduits and sinking for boxes and making good to the disturbed surface of wall/floor and matching with existing specifications. Connections of cable with MCB's or bus bar shall be done through proper size copper/brass thimbles. all as specified and as directed for the following :- (a) One light point controlled by one way switch 5/6 amps.
(b) One ceiling fan/Exhaust fan/Wall Fan point controlled by one way switch 5/6 amps.
(c) One socket out let 5/6 amps point on the independent board
(d) One socket out let 5/6 amps point on the same board
(e) One light point controlled by two way switch 5/6 amps.
All as per item above but wiring with 2.5 sq. mm single core multistranded copper conductor including provision of 2.5 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LS (ISI marked) with proper colour coding as earth continuity conductor connected to common earth dolly , for one socket out let 15/16 amps point on the independent board complete all as specified and directed.
S&F of Modular switch, single pole, one way, 6 Amp, 1 Module, 230 volt, ISI marked complete all as specified and as directed.
S&F of Modular switch, single pole, Two way, 6 Amp, 1 Module, 230 volt, ISI marked complete all as specified and as directed.
S&F of Modular switch, single pole, one way, 16 Amp, 1 Module, 230 volt, ISI marked complete all as specified and as directed.
S&F of Modular shuttered Socket outlet 5 Pin, 6 Amp, 2 Module, 230 volts, ISI marked complete all as specified and as directed.
S&F of Modular shuttered Socket outlet 6 Pin, 6/16 Amp, 2 Module, 230 volts, (ISI marked) complete all as specified and as directed.
S&F of stepped type modular electronic fan regulator 120 watt 2 module suitable for 1200/1400 mm sweep energy saving fans, ISI marked complete all as specified and directed.
S & F lamp holder, insulated body, with back plate suitable for batten/angle fittings complete all as specified and directed.
S&F of LED white glass Lamp 1x9 Watt 230V Base-22 complete all as specified and directed.
S&F of ceiling rose, bakelite, surface type, 220/240 volts, three terminals complete all as specified and directed.
S&F of IP 20, class I, LED light 1X18 W (or nearest next higher wattage) (4feet), 5700K, wall/ surface mounted, integrated type with aluminium housing and decorative and caps with integrated high efficiency electronic driver and surge suppressor of 2KV or more, luminaire efficiency > 95 lumens/watt, power factor > 0.90, operating range - 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/ square blocks, screws etc. complete with all accessories internally prewired and connecting up with and including necessary taking down the old unserviceable fitting complete all as specified.
S&F of IP 20, Class I, LED Mirror light fitting 1 x 9 W, (or nearest next higher wattage) 5700 K, wall /Surface mounted with aluminium housing 2 feet long, integrated type, with high efficiency PMMA diffuser, integrated high efficiency electronic driver & surge suppressor of 2 KV or more, luminaire efficacy > 95 lumens/Watt, power factor >/ 0.90, operating range – 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/square blocks, screws etc. complete including 01 No 10 W LED lamp with all accessories internally prewired and including connecting up with and including twin core twisted flexible copper conductor cable of suitable size including necessary taking down the old unserviceable fitting complete all as specified.
S&F of Bulk head luminaire with B22 base holder suitable for 9 Watt LED inverter type bulb light IP66 grade, with and including 9 watt LED (or nearest next higher wattage) lamp (LED Bulb with B22 base 900 Lumens in normal mode and 450 lumens in power back up mode, charging time 8-10 Hrs and around 4 Hrs Power backup with inbuilt surge protection of 3 KV) (or nearest next higher wattage) and connecting up with and including PVC insulated 3 core of size 0.75 Sqmm copper conductor from ceiling rose to terminal block of light fitting including necessary taking down the old unserviceable fitting complete all as specified.
S & F Energy saving new generation environmental friendly long life versatile pressure die cast aluminium IP 66 security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 35 watts with pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting and GI pipe bracket made out of GI pipe medium grade 32 mm dia 1.5 mtr long bend to required shape complete incl removal of old unsv fitting all as directed by Engineer-in-Charge.
Taking down carefully Ceiling fan from its original position and refixing / hanging after plaster work incl painting of ceiling fan complete, in situ with synthetic enamel paint by spraying including filling cavities with filler one coat after cleaning all dust etc. complete all as specified and directed.
Material and labour for concealed sub-main wiring along with earth wire of size of 2 x 6.0 sq. mm + 1 x6.0 sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including PVC rigid conduit (medium grade) of size not less than 25 mm with all fittings and accessories ISI marked including cutting chases for conduits & making good to walls, floors etc. complete, including taking down old unsv aluminium submain wiring all as specified and as directed. NOTE : Two runs of 6 sqmm conductor for main and one run of 6 sqmm conductor as earth wire with proper colour coding including one run of PVC conduit shall be measured as one unit length. Connections of cables wit MCBs or bus bar shall be done through appropriate size brass/ copper thimbles
S&F of Sheet metal enclosure for 4 way Distribution Boards (DB’s), double door, Triple pole & neutral with 200 amps rated bus bar, 415Volt IP-20 protection suitable for fixing MCB'S/isolators with and including taking down old one complete all as specified and directed.
S&F of moulded case circuit breaker (MCCB) four pole Adjustable type 415 volt, 50 Cycles, 160 Amps of breaking capacity 36 KA after and including taking down / dismantling of old existing unserviceable one complete all as specified and as directed.
S&F of MCB distribution boards (DBs) with sheet metal enclosure, double door, IP 43 protection, 240 Volts, 8 way, single pole and neutral, with 200 Amps rated copper bus bar (as per OEM), neutral link, earth link earthing studs, suitable for fixing MCBs, without MCBs fixed flush to wall/other surface complete all as specified and as directed.
S&F of MCB distribution boards (DBs) with sheet metal enclosure, double door, IP 43 protection, 240 Volts, 4 way, single pole and neutral, with 200 Amps rated copper bus bar (as per OEM), neutral link, earth link earthing studs, suitable for fixing MCBs, without MCBs fixed flush to wall/other surface complete all as specified and as directed.
S&F of MCBs in repairs, Triple pole & neutral 63 amps, 240 volts, ‘C’ curve, 10KA complete all as specified and as directed.
S&F of MCB, Single pole & neutral, 32 to 63 amps, 240 volts, ‘C’ curve, 10KA all complete with and including taking down old unsv one as specified and as directed.
S&F of MCB, Single pole, 5 to 32 amps, 240 volts, ‘C’ curve, 10 KA all complete with and including taking down old unsv one as specified and as directed.
M&L for sheet metal enclosure fabricated out of 2.0 mm thick CRCA sheet, totally enclosed type, dust & vermin proof, with suitable sized supporting MS angles & suitable openings at top & bottom for entry of outgoing / incoming cables, fixed with nuts & bolts & front side openable with hinged shutter with suitable locking arrangement duly painted with 2 coats of powder coated paint over a coat of red oxide primer (spray paint) with minimum dimensions (90 x 75 x 20 cm ) flush to wall for incorporating 01 No TPN DB, 04 Nos electronic meters etc. complete all as specified and as directed.
M&L for earthing complete with galvanized steel plate electrodes of size600x600x6mm thick buried directly in ground with earth pit not less than 2.25 meter deep below normal ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised wire 4.00 mm earth lead by means of nuts, bolts, checknuts and washers including 15 mm bore galvanized iron pipe, medium grade for protection of earth lead up to the length of 7.5 meter towards test terminal and 20 mm bore galvanized iron pipe, medium grade for watering, and providing of charcoal and common salt in alternate layers, including necessary earth work in any type of soil and including PCC pit in PCC 1:2:4 with provision of wire mesh and funnel, complete all as shown in electrical plate No 5 of SSR Part- I including testing on completion all as directed and as specified.
S&F of heavy duty exhaust fan 300 mm sweep MS body with anti-dust painting, 4 blade with heavy duty motor and double ball bearing, 1400 RPM, single phase 230/240 volts copper wounds, complete with all accessories as bird guard/ louvers shutters etc. incl making connections with 3 core flexible multistranded copper conductor of size 0.75 Sqmm run through flexible pipe all as specified and as directed including cutting holes and making good the disturbed surfaces of walls in CM(1:4) and finishing the surface as per existing colour scheme complete all as specified and as directed.
S&F of heavy duty exhaust fan 450 mm sweep MS body with anti-dust painting, 4 blade with heavy duty motor and double ball bearing, 1320 RPM, single phase 230/240 volts copper wounds complete with all accessories as bird guard/ louvers shutters etc. incl making connections with 3 core flexible multistranded copper conductor of size 0.75 Sqmm run through flexible pipe all as specified and as directed including cutting holes and making good the disturbed surfaces of walls in CM(1:4) and finishing the surface as per existing colour scheme complete all as specified and as directed.
S & F for SPN enclosure with two pin and earth plug and socket with 240 volts 32 Amp SPN MCB including removal old unsv one complete all as specified .
Supply and lay pipe galvanized, “Medium class”, including fittings 20 mm fixed complete to walls and ceiling or laid in floor including taking down old unserviceable GI pipe of any size from site as directed by Engineer-in-charge.
Supply and lay pipe galvanized, “Medium class”, including fittings 25 mm including taking down old unserviceable GI pipe of any size from site as directed by Engineer-in-charge.
Supply and lay pipe galvanized, “Medium class”, including fittings 40 mm including taking down old unserviceable GI pipe of any size from site as directed by Engineer-in-charge.
Supply and lay pipe galvanized, “Medium class”, including fittings 50 mm including taking down old unserviceable GI pipe of any size from site as directed by Engineer-in-charge.
Supply and fix Gun metal ,globe Gate Valves with iron wheel head of 20 mm dia bore complete with all accessories all as specified and directed by Engineer-in-charge.
Supply and fix Gun metal ,globe Gate Valves with iron wheel head of 25 mm dia bore complete with all accessories all as specified and directed by Engineer-in-charge.
Supply and fix Gun metal ,globe Gate Valves with iron wheel head of 40 mm dia bore complete with all accessories all as specified and directed by Engineer-in-charge.
Supply and fix Gun metal ,globe Gate Valves with iron wheel head of 50 mm dia bore complete with all accessories all as specified and directed by Engineer-in-charge.
M&L for construction of brick masonary valves pit of internal dimensins 600mm x 600mm x 600mm complete with brick work in cement mortar (1:4) including exvacation and earth work, concrete work and fabrication of 3.0 mm thick MS sheet cover and angle iron frame made out of 40mmx 40mmx6mm MS angle iron and one side provided with hinge with locking arrangement & duly painted with two coats of black bituminous paint over a coat of red oxide primer including necessary earth work and PCC work complete all as specified and as directed
M& L for cutting existing GI pipe alteration or addition of upto 100 mm dia bore for inerstion of reducer Tee complete with all accessories all as specified and directed by Engineer-in-charge.
Taking out old unserviceable cable of any size carefully from trenches ofter disconnecting electric connection, GI pipe protection, with and including separating serviceable bricks & set aside and removing un-serviceable bricks from site complete all as specified and as directed. Note: The Excavation and earth work shall be mesured and paid separately under relevant item of Schedule.
Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated PVC bedded, galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 50 sqmm 3.5 core with and including all fixing & connecting accessories such as Alluminium cable lugs, cable gland, nut, bolts, washer etc complete as specified and as directed. NOTE: Earthwork & Excavation, GI pipe, bricks for protection etc shall be measured and paid separately under relevant items of this schedule.
Supply and lay dry river sand filling for under ground cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed.
Supply and laying sub class B bricks of size 23cmx12.5cmx7.5cm (+/-10% tolerance) for protection of UG cable with width equal to length of bricks as mechanical protection laid dry and flat complete all as specified and as directed.
M & L for horizontal boring across the existing road without disturbing the road surface for inserting GI pipe complete all as specified and as directed. Note :- (i) Removal of surplus soil shall be deemed to be include in the unit Rate. (ii) GI pipe will be measured and paid separately under relevant item of Sch 'A'.
M&L for 50 mm bore steel tubing light grade ISI marked for protection of cable including necessary joints complete all as specified and as directed.
Supply and fixing of moulded case circuit breaker (MCCB) four pole Adjustable type 415 volt, 50 Cycles, 200 Amps of breaking capacity 36 KA after and including taking down / dismantling of old existing unserviceable one complete all as specified and as directed.
Supply installation, commissioning and testing of electric water heater, storage vertical type, BEE 5 star rated 50 ltrs capacity 230 volts AC 50 Hz comprising of high wattage heating element for instant heating extra thick SS inner tank of superior 304 grade, rust & shock proof ABS outer body, non- ferrous prewssure plate with and including provision of 04 Nos grouting bolts suitably flush to wall or any other surfaces 50 lts BEE 5 Star rated complete stranded copper conductor cable/ flexible chord complete all as specified and as directed.
M&L for GI water tubing medium grade 15 mm dia fixed on wall with all fittings and fixtures complete all as specified and directed.
S&F stop valve but fancy type, chromium plated, screwed down (CP) of size 15 mm fancy type complete all as specified and directed.
M&L bib taps , cast copper alloy with butterfly handle , screwed down, screwed for iron pipe or for brass ferrule and fixed for bib tap 15 mm dia fancy type all as specified and as directed.
HARBHAJDAS AGARWAL
M/S R. K. INDUSTRIES
VARNI BUILDERS
M/S JANATA CONSTRUCTION
CHAKRABORTY AND SONS
M/s KASHMIRA SINGH BARMI AND SONS
MAA BHAGWATI ASSOCIATES
DEEP NIRMAN
M/S JYOTI SHARMA AND SONS
STAR CONSTRUCTION
Shri T P ANIL KUMAR
stage.html
html • 0.09 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .