Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹81.8 LAccepted-AOC CUTTACK CUTTACK ODISHA | CUTTACK | ODISHA | 752120 | ₹81.8 L | L1 | Accepted-AOC By The Tender Committee |
| 2 | L2₹81.8 LRejected-Finance | ₹81.8 L | L2 | Rejected-Finance By The Tender Committee |
| 3 | L2₹81.8 LRejected-Finance | ₹81.8 L | L2 | Rejected-Finance By The Tender Committee |
| 4 | L2₹81.8 LRejected-Finance NEAR POLICE COLONY UDITNAGAR ROURKELA 769012 | ROURKELA | SUNDARGARH | ODISHA | 769012 | ₹81.8 L | L2 | Rejected-Finance By The Tender Committee |
| 5 | L2₹81.8 LRejected-Finance AT WARD 8 PO BASANTI COLONY ROURKELA DIST SUNDARGARH ODISHA 769012 | ROURKELA | SUNDARGARH | ODISHA | 769012 | ₹81.8 L | L2 | Rejected-Finance By The Tender Committee |
Tender Value
₹81.8 L
EMD Value
₹81,820
Closing Date
11 Mar 2026, 5:00 pmClosed
Municipal Commissioner, RMC
Rourkela Municipal Corporation, Rourkela
Works
2026_RMC_126681_1
MC/RMC/16/2026
Open Tender
Civil Works - Others
120 days
Rourkela
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
₹81,820
Yes
13 May 2026
26 Feb 2026
12 Mar 2026
26 Feb 2026
11 Mar 2026
26 Feb 2026
CIVIL WORK
Site clearance
Earth work in all kinds of soil within 50 M initial lead and 1.5 M initial lift including rough dressing and breaking clods to maximum 5cm to 7cm. And laying in layers not exceeding 0.3 M in depth and as per direction of the Engineer-in-charge.
For extra lift of 1.5m beyond the initial lift in earth work.
Filling foundation and plinth with excavated Earth ( A.K.S )
Filling foundation and plinth with sand watered and rammed(Labour only)
Fly Ash Brick 23cm x 11cm x 8cm size having crushing strength not less than 75 Kg./Cm2 with dimentional tolerance + 8% in cement mortar (1:6) in foundation & plinth.
Fly Ash Brick 23cm x 11cm x 8cm size having crushing strength not less than 75 Kg./Cm2 with dimentional tolerance + 8% in cement mortar (1:6) in superstructure
Cement concrete (1:2:4) with 12mm size chips
2.5cm. A.S.flooring with cement concrete (1:2:4) including punning using 12mm size HGCB chips.
RCC work of M-20 grade with 20mm & down grade black hard granite (crusher broken) stone chips including hoisting & laying in foundation and plinth.
Col foundation
Plinth Beam
Col.above raft up to bottom of plinth beam
Column
Rigid & smooth centering & shuttering for RCC works: RCC foundtion, plinth band, footing base, columns bass
Rigid & smooth centering & shuttering for RCC works etc
column
2.5cm. Damp proof course with cement concrete (1:2:4)
Supplying fitting and placing uncoated HYSD bar reinforcement complete as per drawing and technical specification.
12mm. thick cement plaster (1:6) for brick work
16mm thick cement plaster (1:6) over brick or stone masonry
Distempering two coats to walls with distemper of approved shade on new work to gve an even shad escluding cost of distmper includinccost of brushes and putty including cost of pait (per one sq. mtr) (for inside)
Priming wall surface One coat with water bound or wall primer per Sqm.
Wall painting Two coats with weather coat paint of approved shade on new work to give an even shade including cost of paint.
Finishing plastered surfaces of walls with plaster of paris & making smooth to receive painting .
Laboour for fixing G.C.I. sheet in roof drilling hole in wind ties including fixing of ridges valleys wind ties etc. excluding cost of fittings.
G.C.I. sheet
Structural steel work in single section, fixed with or without connecting plate, including cutting,
Providing and laying factory made chamfered edge Cement Concrete paver 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. etc
Providing and laying factory made chamfered edge Cement Concrete paver 80mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. etc
Fixing tiles in floors treads or steps and landing on 25mm thick bed of cement mortar 1:1 (1 cement : 1 sand) jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing compelte including cost of pre-caste tiles.
ELECTRICL WORK
Recessed wiring to Light Point / Fan Point / Exhaust Fan Point / Call Bell Point with 1.50 sq. mm FR PVC insulated Single Core Multi standard Copper Conductor of ISI marked with 20 mm dia non-metallic PVC flexible conduit with 5 Amp, 250 Volt piano type swich ISI marked and ceiling rose ISI marked mounted on MS box having front bakelite cover of suitable size, MS box with 1.0 sq. mm FR PVC insulated Single Core Multi standard Copper Conductor of ISI marked as earth wire including all accesories and connection as per direction of engineer in charge. (Make of wire Finolex / L&T / Anchor / Hevels / V Guard)
Midium
Short
5Aplug point
Recessed wiring to Sub-Main in 2 X 2.50 sq. mm FR PVC insulated Single Core Multi standard Copper Conductor of ISI marked with 20 mm dia non-metallic PVC heavy duty flexible conduit with 1.60 mm thick, along with 1 X 1.50 sq. mm FR PVC insulated Single Core Multi standard Copper Conductor as earth wire as required as per direction of Engineer-in-Charge. (Make of wire Finolex / L&T / Anchor / Hevels / V Guard)
Recessed wiring to Sub-Main in 2 X 4.00 sq. mm FR PVC insulated Single Core Multi standard Copper Conductor of ISI marked with 25 mm dia non-metallic PVC heavy duty flexible conduit with 1.60 mm thick, along with 1 X 2.50 sq. mm FR PVC insulated Single Core Multi standard Copper Conductor as earth wire as required as per direction of Engineer-in-Charge. (Make of wire Finolex / L&T / Anchor / Hevels / V Guard)
Recessed wiring to Sub-Main in 2 X 10 sq. mm FR PVC insulated Single Core Multi standard Copper Conductor of ISI marked with 25 mm dia non-metallic PVC heavy duty flexible conduit with 1.60 mm thick, along with 1 X 4 sq. mm FR PVC insulated Single Core Multi standard Copper Conductor as earth wire as required as per direction of Engineer-in-Charge. (Make of wire Finolex / L&T / Anchor / Hevels / V Guard)
Earthing with G.I earth pipe 3 mtr long 40 mm dia ISI mark including accessories and providing machinary enclosure with cover plate having locking arrengement and watering pipe etc. with charcol and salt etc.
Providing and fixing G.I tape 20 mm X 3 mm thick on parapet of surface of wall for lightning conductor complete as per direction of Engineer-in-charge.
Providing and fixing Copper tape 32 mm X 6 mm from earth electrode directly in ground as required.
Supply, Installation, Testing and Commissioning of surface mounted/suspended LED batten with 2x18W tube lights, length 4ft. The luminaire shall have minimum system lumen package not less than 4000 lumens with system efficacy of minimum 120 lumen/watt, available in following color temperatures 4000/5700/6000/6500K (to be decided at the time of execution), min. IP-20 protection. Screw/Bolts/Hole shall be provided at the back of the luminaire for Earth wire termination. The lifeclass of the luminaire should be 50000 burning hours at L70B50 @ design ambient temp 45 deg C. The electronic driver used shall have a power factor >0.95, surge protection of 4kV, THD <10% with output flicker as per IEEE 1789 2015. Luminaire shall have input voltage range of 140-270V with cut off and auto restart voltage at 325 V AC. Driver should be encapsulated, replaceable w/o cutting or (re)soldering any wires on field. The fixture should comply with the parameters as per IS10322. The LED driver should comply to IEC61000-3-2 ed.3.2, 2009 for Harmonics, IEC61347 -2 -13, 2006 in Conjunction with IEC61347-1 ed.2.0, 2007 for Electrical Safety, IEC62384 ed.1.1, 2011 for performance and IEC61547 ed.2.0, 2009, CISPR-15 for EMI. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Both fixture and driver should be BIS approved. The fixture shall include all required accesories etc., with Constant current output Switchable electronic driver complete as required. Similar to Philips TMC100 make or other approved make as per approved list of makes.
Supply & fixing of single spot light of 18 watts complete with 1 no. 18 watt of approved make complete with all necessary fixing materials including termination & labour ( make:- Philips/ Bajaj/ Crompton of Equivalent)
Providing and fixing Single Pole MCB with sheet steel enclosure, distribution board on surface / recess complete with tinned copper bus bar , neutral bus bar, earth bar, din bar, detachable gland plate inter connection phospate and powder painted including earthing etc. as per direction of Engineer-in-charge.With single pole mcb 5 to 32 amp.
Supply, installation, testing and commissoning of 63amp TPN main switch of following capacity (IS 13940 part-3/19930 on existing surface / wall mounting and complete with HRC fuse links inter connections, earthing etc as per direction of Engineer-in-charge.9SEIMENS/HPL/ANCHOR/L&T/HAVELS/C&S/RK)
TOILET BLOCK
Earth work in hard soil or gravelly soil within 50m.initial lead and 1.5m. initial lift including roughdressing and breaking clods to maximum 5Cm. to7C.m.,and laying in layers to exceeding 0.3m., in depth and as per direction of the department.
Filling foundation and plinth with sand watered and rammed(Labour only)
Cement concrete (1:4:8) with 4cm. size hard granite Hand Brocken metal.
2.5cm. A.S.flooring with cement concrete (1:2:4) including punning using 12mm size HGCB chips.
Fly Ash Brick 23cm x 11cm x 8cm size having crushing strength not less than 75 Kg./Cm2 with dimentional tolerance + 8% in cement mortar (1:4) in foundation & plinth.
Fly Ash Brick 23cm x 11cm x 8cm size having crushing strength not less than 75 Kg./Cm2 with dimentional tolerance + 8% in cement mortar (1:6) in superstructure
Brick work (Fly Ash)in cement mortar (1:6) in Superstructure
RCC work of M-20 grade with 20mm & down grade size black hard granite (crusher broken) chips including hoisting & laying in foundation and plinth.
Col foundation
Plinth Beam
Col.above raft up to bottom of plinth beam C-3
Col.above raft up to bottom of plinth beam Ground floor LINTEL
Col.above raft up to bottom of plinth beam Slab Beam G.F
Cloumn Ground floor C-3
Cloumn FF C-3
CHAJJA
Roof slab
Rigid & smooth centering & shuttering for RCC works:RCC foundtion, plinth band, footing base, columns bass
in foundation
Col.above raft up to bottom of plinth beam
Ground floor LINTEL
RCC foundtion, plinth band, footing base, columns bass
Cloumn GF
Cloumn FF
CHAJJA
Roof slab
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size).
Supplying fitting and placing uncoated HYSD bar reinforcement complete as per drawing and technical specification.
Supplying, fitting and fixing of M.S. grill in windows including screws as may be required etc with cost, conveyance, taxes of all materials, labour, T&P etc. required for the complete in all respect.
Supplying all materials, labour T&P and fixing of fabricated M.S door, windows & grill in wall including cutting of brick masonary wall, fixing of door, windows, grill by providing C.C ( 1:2:4 ), Plastering to the damaged portion but exculding the cost of M.S work.
fIXing tiles in floors treads or steps and landing (ceramic floor tiles)
Fixing tiles in dados skiring and risers of steps on 12mm thick cement plaster (1:3) joined with neat cement slurry mixed with pigments to match the shade of the tiles including cost of ceramic wall tiles of approved shade
12mm. thick cement plaster (1:6) for brick work
12mm. thick cement plaster (1:3)
16mm thick cement plaster (1:6) over brick or stone masonry
Distempering two coats to walls with distemper of approved shade on new work to give an even shad excluding cost of distamper including cost of brushes and putty including cost of pait (per one sq. mtr) (for inside)
Wall painting one coat with weather coat paint of approved shade on new work
Finishing walls with water proof cement paint Two coat on new work
Wall painting two coats with plastic emulsion paint
Area(Innser and Outer) GF
Priming one coat with any approved primer
Supplying, fitting and fixing of stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90 Mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in staircase as per approved design and specification, buffinhg, polishing etc. with cost, conveyance, taxes of all materials, labour, T&P etc. required for the work complete in all respect.
2.5cm. thick grading concrete (1:2:2) on roof slab.
1000ltrs.O.H.service tank
Fixing to walls, ceiling and floor unplasticized PVC pipes conforming to ASTM-D-1785/89, the following nominal diameter with fittings and clamps including making good to the damages including testing.
15mm.dia.UPVC pipe [Sch-80 ]=
20mm.dia.UPVC pipe [Sch-80 ]=
25mm.dia.UPVC pipe [Sch-80 ]=
Supplying all materials, labour and T&P for construction of inspection chamber as per P.H. specification and design all complete.
Fixing water closet (I.W.C. or Orissa pan) duly embedded in cement concrete (1:3:6) using 12mm. size h.b.g. chips.
Fixing PVC soil waste and rain water pipes and fittings to walls and jointing with solvent cement of approved quality and fixing to walls with nails,bobbins,clamps and wooden plugs.
Fixing PVC soil waste and rain water pipes and fittings to walls and jointing with solvent cement of approved quality and fixing to walls with nails,bobbins,clamps and wooden plugs.
100mm.dia.PVC door Bend =
100mm.dia.PVC 'P' Trap =
100mm.dia.PVC .Tee =
100mm.dia.PVC cowl. =
100mm.dia.PVC coupler =
Fixing Brass screw down Bib cock / Push cock/Stop cock/ Gun metal Full way valve of the following size as per specification and direction of Engineer-in-charge etc all complete.
15mm.dia. C.P.Bib cock [long body]
15mm.dia. C.P. concealed stop cock
25mm.dia.G.M.Full way valve
Fixing Bowl pattern Urinal including Connecting Urinal of 430x260x350 mm size with waste pipe by means of white lead mixed with chhoped hemp etc all complete
Supplying all materials, labour and T&P for fixing of 10ltrs.capacity low level cistern with a pair of cast iron or M.S.brackets complete with fitting such as siphonic arrangement, 15mm.nominal size brass/PVC ball valve with polythelen float chroium plated brass handle,unions and couplings for connection with inlet,outlet and over flow pipes.40mm.dia.porcelain enamel flush bend,12mm.dia PVC inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and the inlet pipe with supply main etc.all complete as per P.H. specification and direction of Engineer-in-charge.
Fitting water closet squatting pan(indian type WC PAN) duly wmbedded in cement concrete 1:4:8 using hand granite metal 4cm size all complete as per specication
Fixing wash hand basin with hole for pillar cock with cast iron /M.S. brackets painted white including cutting holes in walls and making good to the damages etc. all complete. ( porecelain 22@x16(550x400)WHB
Fixing pedestal for wash hand basin complete recessed at the back for the reception of pipes and fittings etc. all complete.
Supplying all materials,labour and T&P for constructing septic tank with R.C.C. top slab in (1:1.5:3 ) mix with foundation concrete (1:2:4 ) inside plaster 12mm. thick with cement mortar (1:3) finished with neat cement punning, 12mm. thick out side plaster (1:3),brick work with Fly ash bricks(23cm) crushing strength not less than 75kg/cm² in cement mortar (1:3) finished smooth complete as per specification.] 50 users'Septic Tank size[ 3.95x1.10x1.80mtr.]
Supplying all materials,labour and T&P for making of M.S. step iron (rungs) in 20mm. dia M.S. steel bars and fixing into walls :-
Fixing of precast R.C.C. man-hole cover:-
Supplying all materials, labour and T&P for construction of 1.20mtr.dia.x2.55mtr. Deep soak-way pit with dry brick walling up to 2.10mtr. height and bbrick work with cement mortar (1:6) for 0.45mtr. height of wall at top,cement plaster (1:3) inside and outside,inside filled with dry brick khoa of 50mm. to 100mm. size to a height of 2.00mtr. from bottom, covered by means of 40mm. thick R.C.C. perforated slab, 50mm.thick R.C.C. well cover in pieces fitted with iron rings including earth work in excavation and refilling of cavity around the pit as per approved design, drawing, specification and direction of Engineer-in-charge etc. all complete.
CATTALE TRAP
Cattle Trap
Please Enable Macros to View BoQ information
stage.html
html • 0.12 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.93 MB
BOQ_583296.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid