Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.3 LAccepted-AOC | ₹39.3 L Quoted ₹40.2 L | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹44.4 L+₹4.2 L (10.4%)Rejected-Finance 32 GOLA MAHAL P O BARRACKPORE DIST NORTH 24 PARGANAS PIN 700 120 WB | 24 PARAGANAS NORTH | WEST BENGAL | 700120 | ₹44.4 L+₹4.2 L (10.4%) | L2 | Rejected-Finance Not the lowest bidder |
| 3 | L3₹50.6 L+₹10.4 L (26.0%)Rejected-Finance | ₹50.6 L+₹10.4 L (26.0%) | L3 | Rejected-Finance Not the lowest bidder |
| 4 | L4₹53.3 L+₹13.1 L (32.6%)Rejected-Finance 01 BALIA BALIA SAGARDIGHI MURSHIDABAD WEST BENGAL 742237 | MURSHIDABAD | WEST BENGAL | 742237 | ₹53.3 L+₹13.1 L (32.6%) | L4 | Rejected-Finance Not the lowest bidder |
| 5 | L5₹53.4 L+₹13.2 L (32.8%)Rejected-Finance | ₹53.4 L+₹13.2 L (32.8%) | L5 | Rejected-Finance Not the lowest bidder |
Tender Value
₹41.2 L
EMD Value
₹82,400
Closing Date
28 Oct 2021, 6:00 pmClosed
GE Barrackpore
Office of the Garrison Engineer Barrackpore, Kolkata-700120
SPL REPAIR OF STREET LIGHT, STEEL TUBULAR POLES, LT UG CABLE, LT PANEL, CONVERSION OF OVER HEAD LINE TO UG CABLE AND CONNECTED ITEMS AT BARRACKPORE UNDER GE BARRACKPORE
2021_MES_479122_1
8558/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Barrackpore
Refer to tender documents
3 documents required · 3 mandatory
₹500
GE Barrackpore
₹82,400
Yes
18 Dec 2021
1 Oct 2021
29 Oct 2021
1 Oct 2021
28 Oct 2021
16 Oct 2021
Amount
Excavation in trenches for laying under ground cable, foundation and erection of poles and stays in soft/loose soil not exceeding 1.5 meter wide and not exceeding 1.5 meter deep and getting out complete all as specified and directed
Excavation in trenches for laying under ground cable, foundation and erection of poles and stays in soft/loose soil not exceeding 1.5 meter wide and exceeding 1.5 meter but not exceeding 3.0 meter deep and getting out complete all as specified and directed
Returning, filling in, including spreading leveling, watering and well ramming in layers not exceeding 25cm soil all as specified and directed.
Removing surplus excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting points as in soft/loose soil all as specified and directed.
M&L for sand cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep including required watering and consolidation after laying and stretching the cable complete all as specified and directed.
M&L for brick covering with width equal to length of brick as protection to cable with well burnt sub class ‘B’ bricks of size 250mm x 125mm x 75mm laid dry flat complete all as specified and directed .
M&L for providing cement concrete (1:2:4), type B-1 (using 20 mm graded crushed stone aggregate) for coping of poles including necessary form work and finished the surface smooth complete all as specified and directed.
M&L for providing cement concrete (1:4:8), type D-2 (using 40 mm graded crushed stone aggregate) as in foundation, filling for poles complete all as specified and directed
M&L for GI pipe 50mm dia (light grade) complete with all fittings in trenches, road/culvert crossing, floors, on roof, on pole for cable protection complete all as specified and directed.
M&L for GI pipe 40mm dia (light grade) complete with all fittings in trenches, road/culvert crossing, on wall, floors, on roof, on pole for cable protection complete all as specified and directed.
M&L for boring holes horizontally under road without damaging the surface of road (minimum 1.0m bellow the road surfaces) with the help of GI tubing of any dia not exceeding 80mm dia for passing of UG cable complete all as specified and directed.
S&F for steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified conforming to IS- 2317/1980 type 410 SP-31 (9 metres long) complete with cast iron base plate including staying the poles in a truly vertical position till the foundations are properly set, including painting to pole (inside & outside) with two coats of aluminium paint on exposed surfaces of poles and two coats of black bituminous paint on embedded portion after and including dismantling of old unserviceable pole of any description complete all as specified and directed. (Note: Excavation, foundation concrete and coping will be measured and paid separately)
S&F for 70/72 watt LED security light fitting, with LED lamps in aluminium PDC housing, toughened glass cover with IP66 protection with minimum 4kv inbuilt surge protector and cable connection from looping box to light fitting and testing after and including taking down existing unserviceable light fittings complete all as specified and directed . (Make:- Bajaj Cat No. BRTFG 72W LED V3/ Crompton cat No.CRP-409-70-57-SL-GL-NSG /Havells cat No.ENDURACITYLINERNEOSL70WLED757PASYBOTG or equivalent model of Surya as approved)
S&F for LED security light fitting of capacity 90 Watt LED street light fitting in aluminium PDC housing with LED lamp toughened glass cover with IP65 protection with 4/5 KV inbuilt surge protector and cable connection from looping box to light fitting and testing after and including removing of old unserviceable fittings complete all as specified and directed. (Make:-Crompton Greaves cat No.CRP-404-90-57-SL-GL-NSG /Havells cat No.ENDURAPEARLPLUSSL90WLED757PASYTOPCASTHO/Bajaj Cat No. DRTFG90WLEDIV2 or equivalent model of Surya as approved)
S&F for LED flood light fitting of capacity 120 Watt in aluminium PDC housing with LED lamp, toughened glass cover with IP66 protection with 4/5 KV inbuilt surge protector and cable connection from looping box to light fitting at any height and testing after and including taking down existing unserviceable light fittings complete all as specified and directed . (Make:-Crompton Cat ref No.LFLN-120-CDL/60-M /Havells cat No. JETAIRISFLS120WLED757APWBLTG /Bajaj Cat No.BJFL 120W LED I or equivalent model of Surya as approved)
Supply, fabricated and fixing of street light bracket made out of GI pipe 40mm dia medium grade bent to shape of 1.2 mtr long as directed including clamps made out of 30 mm x 6 mm-02 Nos flat iron for fixing bracket suitable for steel tubular poles including nuts and bolts, washers and other connected items of required size including painting with two coats of aluminium paint over a coat of red oxide primer after and including taking down old existing unserviceable bracket complete all as specified and directed .
M&L for earthing complete with galvanised steel earth plate electrode of size 600mm x 600mm x 6mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised steel earth strip of size 32 x 6mm earth lead by means of nuts, bolts, check nuts, washers of galvanised iron as steel, protected by galvanised iron pipe 40mm bore (Medium grade) all as directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil all as shown in electrical plate No 3 of SSR Part I including testing on completion after and including taking out existing unserviceable earthing complete all as specified and directed . (Galvanised strip upto 7.5m including testing consider in this item).
M&L for XLPE insulated, LT armoured electric cable with aluminium stranded conductor 1100 volts grade, cross-sectional area 35 sqmm, 3.5 core laid in trenches/pipes/ducts/wall/borings with necessary cable lugs and glands, nuts, bolts and washers etc and testing after and including taking out existing unserviceable cable complete all as specified and directed. (NOTE: Excavation/earth work, sand cushioning, cable cover/brick shall be measured and paid separately if required)
M&L for XLPE insulated, LT armoured electric cable with aluminium stranded conductor 1100 volts grade, cross-sectional area 95 sqmm, 3.5 core laid in trenches/pipes/ducts/wall/borings with necessary cable lugs and glands, nuts, bolts and washers etc and testing complete all as specified and directed . (NOTE: Excavation/earth work, sand cushioning, cable cover/brick shall be measured and paid separately if required)
M&L for XLPE insulated, LT armoured electric cable with aluminium stranded conductor 1100 volts grade, cross-sectional area 95 sqmm, 3.5 core laid in trenches/pipes/ducts/wall/borings with necessary cable lugs and glands, nuts, bolts and washers etc and testing after and including taking out existing unserviceable cable complete all as specified and directed. (NOTE: Excavation/earth work, sand cushioning, cable cover/brick shall be measured and paid separately if required)
M&L for XLPE insulated, LT armoured electric cable with aluminium stranded conductor 1100 volts grade, cross-sectional area 16 sqmm, 4 core laid in trenches/pipes/ducts/wall/borings with necessary cable lugs and glands, nuts, bolts and washers etc and testing complete all as specified and directed . (NOTE: Excavation/earth work, sand cushioning, cable cover/brick shall be measured and paid separately if required)
M&L for XLPE insulated, LT armoured electric cable with aluminium stranded conductor 1100 volts grade, cross-sectional area 25 sqmm, 4 core laid in trenches/pipes/ducts/wall/borings with necessary cable lugs and glands, nuts, bolts and washers etc and testing complete all as specified and directed . (NOTE: Excavation/earth work, sand cushioning, cable cover/brick shall be measured and paid separately if required)
M&L for PVC conduit heavy duty of size 20mm dia from looping box to street light connector, holding in MS clamp of size 25X3 mm thick at every one mtr used in each pole 04 Nos of clamps with necessary nut, bolts and washers etc including PVC sheathed three core multistranded copper conductor cable of size 1.5 sqmm from looping box to light fittings connector after and including taking out old unserviceable one complete all as specified and directed.
S&F for hot press moulded SMC junction box of size 350mm X250mm X150mm hinged type with incoming and outgoing connector/terminals and comprising of MCB, SP, 6 Amps, 240V, 10KA, 'C' Series and including MS flat iron clamps of size 25X5mm thick -02 Nos, nuts, bolts & washers etc for fixing on PCC/Steel tubular pole/ wall surface etc after and including removing of old unserviceable item complete all as specified and directed. (Make:- Sintex/Hensel as approved)
Supply, installation, testing and commissioning of factory made CPRI approved LT feeder pillar box (FPB) (out door type) of size 1200 mm (H) x 1200 mm (L) x 500 mm (W), suitable for working on 3 phase, 4 wire, 415 volts, AC, 50Hz, cubicle, floor mounted, free standing, dust and vermin proof, air ventilation with IP-54 protection made, out of 3.15mm thick CRCA sheet and frame (all sides) made of angle iron (50mmX50mmX6mm) and flats (50 x 6 mm) duly epoxy powder coated (seven tank process) compartmentrised with rubber gasket, hinged doors with handle. FPB shall have front and rear opening, locking arrangement with control fuses see through glass arrangement, cable entry holes, aluminium busbar chamber, switch gear compartment, earthing terminals, affix danger notice plate, control copper wiring of adequate size and length etc the panel will be mounted on 50mm x 50mm x 6mm mild steel angle iron frame of height 45cm above floor level/ground level as per site requirement, and grouted legs below 45cm and including connecting up of existing incoming and out going cables by using new aluminium lugs and cable gland and connecting of earth strip and providing PCC (1:3:6) type C-1 as foundation as per site requirement etc and drawing/circuit layout as approved with the following accessories after disconnecting of electric supply and earth conductor etc after and including dismantling of existing old unserviceable FPB with all accessories/mounting etc complete all as specified and directed :-
(a) MCCB 250 Amps, FP, 36 KA, 415 Volts, 50 Hz-01 No (b) MCCB 100 Amps, FP, 25 KA, 415 Volts, 50 Hz-01 No (c) MCCB 63 Amps, FP, 25 KA, 415 Volts, 50 Hz-04 Nos (d)Analogue time switch (daily time switch) with suitable power contactor 63 Amps, ML-2 type, 3 Phase, 415 Volts, auto/manual operating switches-01 No (e)Digital voltmeter with VSS-01 Set (f) Digital Ammeter with CTs and ASS-01 Set (g) LED phase indication lamps RYB -01 Set (h) Aluminium bus bar TPN 400 Amps (04 Nos) rating-01 Set
Supply, installation, testing and commissioning of factory made CPRI approved LT feeder pillar box (FPB) (out door type) of size 1200 mm (H) x 1200 mm (L) x 600 mm (W), suitable for working on 3 phase, 4 wire, 415 volts, AC, 50Hz, cubicle, floor mounted, free standing, dust and vermin proof, air ventilation with IP-54 protection made, out of 3.15mm thick CRAC sheet and frame (all sides) made of angle iron (50mmX50mmX6mm) and flats (50 x 6 mm) duly epoxy powder coated (seven tank process) compartmentrised with rubber gasket, hinged doors with handle. FPB shall have front and rear opening, locking arrangement with control fuses see through glass arrangement, cable entry holes, aluminium busbar chamber, switch gear compartment, earthing terminals, affix danger notice plate, control copper wiring of adequate size and length etc the panel will be mounted on 50mm x 50mm x 6mm mild steel angle iron frame of height 45cm above floor level/ground level as per site requirement, and grouted legs below 45cm and including connecting up of existing incoming and out going cables by using new aluminium lugs and cable gland and connecting of earth strip and providing PCC (1:3:6) type C-1 as foundation as per site requirement etc and drawing/circuit layout as approved with the following accessories after disconnecting of electric supply and earth conductor etc after and including dismantling of existing old unserviceable FPB with all accessories/mounting etc complete all as specified and directed :-
(a) MCCB 250 Amps, FP, 25 KA, 415 Volts, 50 Hz-01 No (b) MCCB 200 Amps, FP, 25 KA, 415 Volts, 50 Hz-01 No (c) MCCB 100 Amps, FP, 16 KA, 415 Volts, 50 Hz-02 Nos (d) MCCB 63 Amps, FP, 16 KA, 415 Volts, 50 Hz-05 Nos (e) Analogue time switch (daily time switch) with suitable power contactor 63 Amps, ML-2 type, 3 Phase, 415 Volts, auto/manual operating switches-01 No (f)Digital voltmeter with VSS-01 Set (g) Digital Ammeter with CTs and ASS-01 Set (h) LED phase indication lamps RYB -01 Set (j) Aluminium bus bar TPN 400 Amps (04 Nos) rating-01 Set
Supply, installation, testing and commissioning of factory made CPRI approved LT feeder pillar box (FPB) (out door type) of size 1500 mm (H) x 1400 mm (L) x 600 mm (W), suitable for working on 3 phase, 4 wire, 415 volts, AC, 50Hz, cubicle, floor mounted, free standing, dust and vermin proof, air ventilation with IP-54 protection made, out of 3.15mm thick CRAC sheet and frame (all sides) made of angle iron (50mmX50mmX6mm) and flats (50 x 6 mm) duly epoxy powder coated (seven tank process) compartmentrised with rubber gasket, hinged doors with handle. FPB shall have front and rear opening, locking arrangement with control fuses see through glass arrangement, cable entry holes, aluminium busbar chamber, switch gear compartment, earthing terminals, affix danger notice plate, control copper wiring of adequate size and length etc the panel will be mounted on 50mm x 50mm x 6mm mild steel angle iron frame of height 45cm above floor level/ground level as per site requirement, and grouted legs below 45cm and including connecting up of existing incoming and out going cables by using new aluminium lugs and cable gland and connecting of earth strip and providing PCC (1:3:6) type C-1 as foundation as per site requirement etc and drawing/circuit layout as approved with the following accessories after disconnecting of electric supply and earth conductor etc after and including dismantling of existing old unserviceable FPB with all accessories/mounting etc complete all as specified and directed :-
(a) MCCB 320 Amps, FP, 25 KA, 415 Volts, 50 Hz-01 No (b) MCCB 160 Amps, FP, 25 KA, 415 Volts, 50 Hz-01 No (c) MCCB 63 Amps, FP, 16 KA, 415 Volts, 50 Hz-02 Nos (d) MCB 40 Amps, TPN, 10 KA, 415 Volts, 50 Hz-05 Nos (e) Analogue time switch (daily time switch) with suitable power contactor 63 Amps, ML-2 type, 3 Phase, 415 Volts, auto/manual operating switches-01 No (f)Digital voltmeter with VSS-01 Set (g) Digital Ammeter with CTs and ASS-01 Set (h) LED phase indication lamps RYB -01 Set (j) Aluminium bus bar TPN 300 Amps (04 Nos) rating-01 Set
Dismantling of old unserviceable ACSR conductor from existing pole of any type and including MS clamps, cross arm, nut, bolts and washers etc at any height and deposited to MES Store Yard Barrackpore complete all as specified and directed.
SENCO
MAZUMDER AND CO
DAS ENTERPRISE
BEE ROMEN
M/S H.P Singha
N S CONSTRUCTION
M/S RAJESH TRADING CO
NANDY ENTERPRISE
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .