| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.4 LAccepted-AOC | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹50.0 L+₹86,998 (1.77%)Rejected-Finance D NO 49 23 27 A FLAT NO 301 3RD FLOOR SRI SAI TIRUMAL ENCLAVE LALITHANAGAR VISAKHAPATNAM 530 016 | VISAKHAPATANAM | ANDHRA PRADESH | 530016 | L2 | Rejected-Finance Not being lowest bidder | |
| 3 | L3₹50.1 L+₹95,013 (1.93%)Rejected-Finance | L3 | Rejected-Finance Not being lowest bidder | |
| 4 | L4₹50.8 L+₹1.7 L (3.43%)Rejected-Finance | L4 | Rejected-Finance Not being lowest bidder | |
| 5 | L5₹51.2 L+₹2.0 L (4.16%)Rejected-Finance | L5 | Rejected-Finance Not being lowest bidder |
| Sl No | Description | Qty | Unit | SATYAMEGHA ENGINEERS L5 | G Srinivas Rao L2 | M/S CHANDRA ENGINEERS AND CONTRACTORS L9 | ANJALI ENTERPRISES L8 | M/s KAMADHENU ENGINEERING CONSTRUCTIONS L7 | UV POWER TECH L4 | K.ADITYA ENGINEERING CONTRACTORS L3 | PRAHJVAL CONSTRUCTIONS L1 | MERIDIAN CONSTRUCTIONS PRIVATE LIMITED L6 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00NOTES/INSTRUCTIONS FOR STRICT COMPLIANCE (a) The contractor shall obtain sample approval for all materials for incorporating in the work as per condition 10 of IAFW-2249 and Para-12 of Special Conditions of tender document mentioned here-in-after. (b) The GE may direct the contractor in writing to procure and deposit up to 80% of the material required for the complete scope of work. The decision shall be final and binding on the contractor. (c) The contractor shall deposit the procured material under intimation to GE to the store of concerned subdivision within 30 days from the receipt of written direction. Failure to do so shall result in a penal recovery of Rs 2000/- per week, levied on the dues of contractor, maximum up to 10% of the work done/CA Amount whichever is higher. (d)The contractor shall obtain approval of “Qualified Tradesman” as per condition 26 of IAFW-2249 before commencement of work at site and shall have sufficient manpower such as plumber, welder, helper etc readily avialble to meet the site requirement during emergency situation as per directions of Engineer-in-Charge/GE. | ||||||||||||
| 1.01NOTES(Contd---) (e)The breakdown/Leakeges should be attended well within time mentioned here-in-after from the time of intimation (through Verbal/Site Order/Written) by the Engineer-in-Charge/GE, failing which a penal recovery of Rs 500/- per hour shall be deducted from contractors dues: Size of Pipe Time limit to attend Breakdown & Completion Upto 50mm 6 Hrs 50mm-100mm 8 Hrs More than 100mm 12 Hrs (f) The quoted rates shall be inclusive of cost of necessary Tools, Plants, Safety Equipments, Machinery, Arrangements of Manual Dewatering/Dewatering pumps and Temporary lighting arrangements for work during night time etc as per site requirement. (g) The quoted rates shall be inclusive of cost for necessary scaffolding for working upto 9th floor level of multi-storyed Buildings under AoR of GE (U-II). | ||||||||||||
| 2.00 | Labour only for attending breakdowns / leakage complaints of underground pipe lines of any type and description such as DI / CI / MS of size 200mm to 300mm bore dia by cleaning the pipe line surfaces, identifying the leakage / breakdown of pipe line, removing the damaged portion of pipe line from trenches by gas cutting / manual cutting as per site requirement, replacing with new pipe line / fittings / accessories by fixing / welding / threading as per site requirement and testing after completion for leak proof working complete all as specified and directed by Engineer-in-Charge.
Note: Excavation, earth work, PCC, Pipes, fittings, accessories etc as required at site shall be measured and paid separately as "Supply Only" under relevant items of BOQ. However, the Quoted rate shall be inclusive of the following provisions:-
(i) Breakdown / leakages should be attended and completed within 24 hours from the time of intimation to contractor by JE E/M / Engineer-in-Charge, failing which, penal recovery of Rs. 500 per hour shall be deducted from contractor dues.
(ii) Sufficient manpower such as Plumber, Welder and helpers as per site requirement shall be provided by contractor to ensure the work to be completed within the time specified by Engineer-in-Charge.
(iii) Necessary arrangement for manual dewatering / dewatering pump as required at site to complete the work within the specified time.
(iv) Necessary Tools, Plants, Safety Equipment, machinery and temporary lighting arrangement to work during night time etc as required at site shall be provided by the contractor. | 1 | Each Job | 26,750 ₹26,750 | 24,432 ₹24,432 | 27,500 ₹27,500 | 27,000 ₹27,000 | 25,553 ₹25,553 | 24,200 ₹24,200 | 24,676 ₹24,676 | 24,000 ₹24,000 Lowest | 24,930 ₹24,930 |
| 3.00 | All as per item No. 2.00 here-in-before but of size 100mm / 150mm bore dia. | 5 | Each Job | 16,750 ₹83,750 | 16,288 ₹81,440 | 19,000 ₹95,000 | 18,500 ₹92,500 | 17,035 ₹85,175 | 1,620 ₹8,100 Lowest | 16,451 ₹82,255 | 16,000 ₹80,000 | 16,641 ₹83,205 |
| 4.00 | All as per item No. 2.00 here-in-before but of GI / PPR pipe of size 40mm to 80mm bore dia. | 15 | Each Job | 8,000 ₹1,20,000 Lowest | 8,144 ₹1,22,160 | 9,600 ₹1,44,000 | 9,500 ₹1,42,500 | 8,518 ₹1,27,770 | 8,200 ₹1,23,000 | 8,225 ₹1,23,375 | 8,000 ₹1,20,000 Lowest | 8,325 ₹1,24,875 |
| 5.00 | All as per item No. 2.00 here-in-before but of GI / PPR pipe of size 15mm to 32mm bore dia. | 20 | Each Job | 3,750 ₹75,000 | 3,054 ₹61,080 | 3,300 ₹66,000 | 3,200 ₹64,000 | 3,194 ₹63,880 | 3,300 ₹66,000 | 3,085 ₹61,700 | 3,000 ₹60,000 Lowest | 3,123 ₹62,460 |
| 6.00 | Labour only for attending breakdowns / leakage complaints of pipe lines of any type and description such as DI / CI / MS of size 200mm to 300mm bore dia on ground / floors inside buildings / on roof top of buildings etc by cleaning the pipe line surfaces, identifying the leakage / breakdown of pipe line, removing the damaged portion of pipe line by gas cutting / manual cutting as per site requirement, replacing with new pipe line / fittings / accessories by fixing / welding / threading as per site requirement and testing after completion for leak proof working complete all as specified and directed by Engineer-in-Charge.
Note: Pipes, fittings, accessories etc as required at site shall be measured and paid separately as "Supply Only" under relevant items of BOQ. However, the Quoted rate shall be inclusive of the following provisions:-
(i) Breakdown / leakages should be attended and completed within 24 hours from the time of intimation to contractor by JE E/M / Engineer-in-Charge, failing which, penal recovery of Rs. 500 per hour shall be deducted from contractor dues.
(ii) Sufficient manpower such as Plumber, Welder and helpers as per site requirement shall be provided by contractor to ensure the work to be completed within the time specified by Engineer-in-Charge.
(iii) Necessary Tools, Plants, Safety Equipment, machinery and temporary lighting arrangement to work during night time etc as required at site shall be provided by the contractor. | 1 | Each Job | 15,000 ₹15,000 | 13,743 ₹13,743 | 13,600 ₹13,600 | 13,500 ₹13,500 Lowest | 14,373 ₹14,373 | 13,750 ₹13,750 | 13,880 ₹13,880 | 13,500 ₹13,500 Lowest | 14,040 ₹14,040 |
| 7.00 | All as per item No. 6.00 here-in-before but of size 100mm / 150mm bore dia. | 5 | Each Job | 9,750 ₹48,750 | 9,162 ₹45,810 | 9,300 ₹46,500 | 9,250 ₹46,250 | 9,582 ₹47,910 | 9,250 ₹46,250 | 9,254 ₹46,270 | 9,000 ₹45,000 Lowest | 9,360 ₹46,800 |
| 8.00 | All as per item No. 6.00 here-in-before but of GI / PPR pipe of size 40mm to 80mm bore dia. | 15 | Each Job | 4,750 ₹71,250 Lowest | 5,090 ₹76,350 | 5,700 ₹85,500 | 5,750 ₹86,250 | 5,324 ₹79,860 | 5,250 ₹78,750 | 5,141 ₹77,115 | 5,000 ₹75,000 | 5,220 ₹78,300 |
| 9.00 | All as per item No. 6.00 here-in-before but of GI / PPR pipe of size 15mm to 32mm bore dia. | 35 | Each Job | 2,500 ₹87,500 Lowest | 2,545 ₹89,075 | 2,700 ₹94,500 | 2,750 ₹96,250 | 2,662 ₹93,170 | 2,600 ₹91,000 | 2,570 ₹89,950 | 2,500 ₹87,500 Lowest | 2,610 ₹91,350 |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
18 Aug 2025, 6:00 pmClosed
Garrison Engineer Utility-II Visakhapatnam
Garrison Engineer Utility-II 104 Area Industrial Estate Post Visakhapatnam -530 007
ATTG BRKDOWNS COMPLTOF WPLINES INCLUDING REPAIR REPLAC RENEWALOFVARIOUS WS PIPELINES VALVES REPAIR MAINTTO PUMPS MOTORS CONTROL PANELS AND CONT WRKS AT NAUSHAKTIVIHAR MPETACOLONY ASHOKAPARK NAMAC NSB MOV NEWSITE WEDV UNDER GEU IIV
2025_MES_722345_1
8074(A)
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Garrison Engineer Utility-II Visakhapatnam
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Garrison Engineer Utility-II
₹94,000
Yes
15 Sept 2025
24 Jul 2025
19 Aug 2025
24 Jul 2025
18 Aug 2025
13 Aug 2025
25 Jul 2025 - 26 Jul 2025
Amount
NOTES/INSTRUCTIONS FOR STRICT COMPLIANCE (a) The contractor shall obtain sample approval for all materials for incorporating in the work as per condition 10 of IAFW-2249 and Para-12 of Special Conditions of tender document mentioned here-in-after. (b) The GE may direct the contractor in writing to procure and deposit up to 80% of the material required for the complete scope of work. The decision shall be final and binding on the contractor. (c) The contractor shall deposit the procured material under intimation to GE to the store of concerned subdivision within 30 days from the receipt of written direction. Failure to do so shall result in a penal recovery of Rs 2000/- per week, levied on the dues of contractor, maximum up to 10% of the work done/CA Amount whichever is higher. (d)The contractor shall obtain approval of “Qualified Tradesman” as per condition 26 of IAFW-2249 before commencement of work at site and shall have sufficient manpower such as plumber, welder, helper etc readily avialble to meet the site requirement during emergency situation as per directions of Engineer-in-Charge/GE.
NOTES(Contd---) (e)The breakdown/Leakeges should be attended well within time mentioned here-in-after from the time of intimation (through Verbal/Site Order/Written) by the Engineer-in-Charge/GE, failing which a penal recovery of Rs 500/- per hour shall be deducted from contractors dues: Size of Pipe Time limit to attend Breakdown & Completion Upto 50mm 6 Hrs 50mm-100mm 8 Hrs More than 100mm 12 Hrs (f) The quoted rates shall be inclusive of cost of necessary Tools, Plants, Safety Equipments, Machinery, Arrangements of Manual Dewatering/Dewatering pumps and Temporary lighting arrangements for work during night time etc as per site requirement. (g) The quoted rates shall be inclusive of cost for necessary scaffolding for working upto 9th floor level of multi-storyed Buildings under AoR of GE (U-II).
Labour only for attending breakdowns / leakage complaints of underground pipe lines of any type and description such as DI / CI / MS of size 200mm to 300mm bore dia by cleaning the pipe line surfaces, identifying the leakage / breakdown of pipe line, removing the damaged portion of pipe line from trenches by gas cutting / manual cutting as per site requirement, replacing with new pipe line / fittings / accessories by fixing / welding / threading as per site requirement and testing after completion for leak proof working complete all as specified and directed by Engineer-in-Charge. Note: Excavation, earth work, PCC, Pipes, fittings, accessories etc as required at site shall be measured and paid separately as "Supply Only" under relevant items of BOQ. However, the Quoted rate shall be inclusive of the following provisions:- (i) Breakdown / leakages should be attended and completed within 24 hours from the time of intimation to contractor by JE E/M / Engineer-in-Charge, failing which, penal recovery of Rs. 500 per hour shall be deducted from contractor dues. (ii) Sufficient manpower such as Plumber, Welder and helpers as per site requirement shall be provided by contractor to ensure the work to be completed within the time specified by Engineer-in-Charge. (iii) Necessary arrangement for manual dewatering / dewatering pump as required at site to complete the work within the specified time. (iv) Necessary Tools, Plants, Safety Equipment, machinery and temporary lighting arrangement to work during night time etc as required at site shall be provided by the contractor.
All as per item No. 2.00 here-in-before but of size 100mm / 150mm bore dia.
All as per item No. 2.00 here-in-before but of GI / PPR pipe of size 40mm to 80mm bore dia.
All as per item No. 2.00 here-in-before but of GI / PPR pipe of size 15mm to 32mm bore dia.
Labour only for attending breakdowns / leakage complaints of pipe lines of any type and description such as DI / CI / MS of size 200mm to 300mm bore dia on ground / floors inside buildings / on roof top of buildings etc by cleaning the pipe line surfaces, identifying the leakage / breakdown of pipe line, removing the damaged portion of pipe line by gas cutting / manual cutting as per site requirement, replacing with new pipe line / fittings / accessories by fixing / welding / threading as per site requirement and testing after completion for leak proof working complete all as specified and directed by Engineer-in-Charge. Note: Pipes, fittings, accessories etc as required at site shall be measured and paid separately as "Supply Only" under relevant items of BOQ. However, the Quoted rate shall be inclusive of the following provisions:- (i) Breakdown / leakages should be attended and completed within 24 hours from the time of intimation to contractor by JE E/M / Engineer-in-Charge, failing which, penal recovery of Rs. 500 per hour shall be deducted from contractor dues. (ii) Sufficient manpower such as Plumber, Welder and helpers as per site requirement shall be provided by contractor to ensure the work to be completed within the time specified by Engineer-in-Charge. (iii) Necessary Tools, Plants, Safety Equipment, machinery and temporary lighting arrangement to work during night time etc as required at site shall be provided by the contractor.
All as per item No. 6.00 here-in-before but of size 100mm / 150mm bore dia.
All as per item No. 6.00 here-in-before but of GI / PPR pipe of size 40mm to 80mm bore dia.
All as per item No. 6.00 here-in-before but of GI / PPR pipe of size 15mm to 32mm bore dia.
Labour only for attending breakdowns / leakage complaints of pipe lines of any type and description such as MS / GI / PPR of size 63mm to 100mm bore dia on walls of buildings up to 3rd floor by cleaning the pipe line surfaces, identifying the leakage / breakdown of pipe line, removing the damaged portion of pipe line by gas cutting / manual cutting as per site requirement, replacing with new pipe line / fittings / accessories by fixing / welding / threading / Heating as per site requirement and testing after completion for leak proof working complete all as specified and directed by Engineer-in-Charge. Note: Pipes, fittings, accessories etc as required at site shall be measured and paid separately as "Supply Only" under relevant items of BOQ. However, the Quoted rate shall be inclusive of the following provisions:- (i) Breakdown / leakages should be attended and completed within 24 hours from the time of intimation to contractor by JE E/M / Engineer-in-Charge, failing which, penal recovery of Rs. 500 per hour shall be deducted from contractor dues. (ii) Sufficient manpower such as Plumber, Welder and helpers as per site requirement shall be provided by contractor to ensure the work to be completed within the time specified by Engineer-in-Charge. (iii) Necessary Tools, Plants, Safety Equipment, machinery and temporary lighting arrangement to work during night time etc as required at site shall be provided by the contractor. (iv) Necessary scaffolding for working up to 3rd floor level of building.
All as per item No. 10.00 here-in-before but of GI / PPR pipe of size 32mm to 50mm bore dia.
Labour only for attending breakdowns / leakage complaints of pipe lines of any type and description such as MS / GI / PPR of size 63mm to 100mm bore dia walls of buildings above 3rd floor and up to 6th floor of multistoried building of G+9 configuration by cleaning the pipe line surfaces, identifying the leakage / breakdown of pipe line, removing the damaged portion of pipe line by gas cutting / manual cutting as per site requirement, replacing with new pipe line / fittings / accessories by fixing / welding / threading / Heating as per site requirement and testing after completion for leak proof working complete all as specified and directed by Engineer-in-Charge. Note: Pipes, fittings, accessories etc as required at site shall be measured and paid separately as "Supply Only" under relevant items of BOQ. However, the Quoted rate shall be inclusive of the following provisions:- (i) Breakdown / leakages should be attended and completed within 24 hours from the time of intimation to contractor by JE E/M / Engineer-in-Charge, failing which, penal recovery of Rs. 500 per hour shall be deducted from contractor dues. (ii) Sufficient manpower such as Plumber, Welder and helpers as per site requirement shall be provided by contractor to ensure the work to be completed within the time specified by Engineer-in-Charge. (iii) Necessary Tools, Plants, Safety Equipment, machinery and temporary lighting arrangement to work during night time etc as required at site shall be provided by the contractor. (iv) Necessary scaffolding for working up to 6th floor level of multistoried building.
Labour only for attending breakdowns / leakage complaints of pipe lines of any type and description such as MS / GI / PPR of size 63mm to 100mm bore dia walls of buildings above 6th floor and up to 9th floor of multistoried building of G+9 configuration by cleaning the pipe line surfaces, identifying the leakage / breakdown of pipe line, removing the damaged portion of pipe line by gas cutting / manual cutting as per site requirement, replacing with new pipe line / fittings / accessories by fixing / welding / threading / Heating as per site requirement and testing after completion for leak proof working complete all as specified and directed by Engineer-in-Charge. Note: Pipes, fittings, accessories etc as required at site shall be measured and paid separately as "Supply Only" under relevant items of BOQ. However, the Quoted rate shall be inclusive of the following provisions:- (i) Breakdown / leakages should be attended and completed within 24 hours from the time of intimation to contractor by JE E/M / Engineer-in-Charge, failing which, penal recovery of Rs. 500 per hour shall be deducted from contractor dues. (ii) Sufficient manpower such as Plumber, Welder and helpers as per site requirement shall be provided by contractor to ensure the work to be completed within the time specified by Engineer-in-Charge. (iii) Necessary Tools, Plants, Safety Equipment, machinery and temporary lighting arrangement to work during night time etc as required at site shall be provided by the contractor. (iv) Necessary scaffolding for working up to 9th floor level of multistoried building.
Supply only CI / DI fittings suitable for CI / DI pipe of size 80mm to 300mm bore and any type such as Bends (any type, radius and angle), tapers any type (straight, bend, increasing, decreasing or double socket etc), Tee pieces (single branch, "Y" junction, double branch, cross etc), caps and plugs etc, complete all as specified and directed by Engineer-in-Charge.
Supply only DI Mechanical joint (MJ) collar with rubber ring complete suitable for CI/DI pipe line of size 80mm to 100mm bore dia with and including all jointing material complete all as specified and directed by Engineer-in-Charge.
Supply only DI Mechanical joint (MJ) collar with rubber ring complete suitable for CI/DI pipe line of size 150mm bore dia with and including all jointing material complete all as specified and directed by Engineer-in-Charge.
Supply only DI Mechanical joint (MJ) collar with rubber ring complete suitable for CI/DI pipe line of size 200 to 300 mm bore dia with and including all jointing material complete all as specified and directed by Engineer-in-Charge.
Supply only MS clamp with rubber gasket, nuts, bolts and washers etc as required at site for pipe size 40mm / 50mm bore dia complete all as specified and directed by Engineer-in-Charge.
Supply only MS clamp with rubber gasket, nuts, bolts and washers etc as required at site for pipe size 80mm / 100mm bore dia complete all as specified and directed by Engineer-in-Charge.
Supply only MS clamp with rubber gasket, nuts, bolts and washers etc as required at site for pipe size 150mm / 200mm bore dia complete all as specified and directed by Engineer-in-Charge.
Supply only MS clamp with rubber gasket, nuts, bolts and washers etc as required at site for pipe size 250mm / 300mm bore dia complete all as specified and directed by Engineer-in-Charge.
Supply only Ductile iron pipe (Conforming to IS: 8329-2000), Centrifugally Cast (Spun) Pressure Pipe with Socket and Spigot ends suitable for Push-on-Joint including jointing material, duly applied with Zinc Coating with finishing layer of Bitumen on external surfaces and Cement Motor Lining with Bituminous Seal Coat on internal surfaces complete of size 100mm bore class K-9 complete all as specified and directed by Engineer-in-Charge.
All as per item No. 22.00 here-in-before but of size 150mm dia bore
All as per item No. 22.00 here-in-before but of size 200mm dia bore
All as per item No. 22.00 here-in-before but of size 250mm / 300mm dia bore
Supply only MS ERW Pipe P/E as Per IS:3589 Gr. 330, nominal bore 150 mm dia heavy grade complete all as specified and directed by Engineer-in-Charge.
Supply only MS ERW Pipe P/E as Per IS:3589 Gr. 330, nominal bore 200 mm dia, wall thickness 5 mm complete all as specified and directed by Engineer-in-Charge.
Supply only MS ERW Pipe P/E as Per IS:3589 Gr. 330, nominal bore 250 mm / 300mm dia, wall thickness 5 mm complete all as specified and directed by Engineer-in-Charge.
Supply only MS slip-on weldable flange suitable for 150 mm NB pipe, complete all as specified and directed by Engineer-in-Charge.
Supply only MS slip-on weldable flange suitable for 200 mm NB pipe, complete all as specified and directed by Engineer-in-Charge.
Supply only MS slip-on weldable flange suitable for 250 mm / 300 mm NB pipe, complete all as specified and directed by Engineer-in-Charge.
Supply only flange joint with rubber or fiber board gasket including suitable bolts, nuts and washers for 150 mm NB pipe, complete all as specified and directed by Engineer-in-Charge.
Supply only flange joint with rubber or fiber board gasket including suitable bolts, nuts and washers for 200 mm NB pipe, complete all as specified and directed by Engineer-in-Charge.
Supply only flange joint with rubber or fiber board gasket including suitable bolts, nuts and washers for 250 / 300 mm NB pipe, complete all as specified and directed by Engineer-in-Charge.
Supply only Material for Run lead joint for 150mm NB CI/DI pipe, complete all as specified and directed by Engineer-in-Charge.
Supply only Material for Run lead joint for 200mm NB CI/DI pipe, complete all as specified and directed by Engineer-in-Charge.
Supply only Material for Run lead joint for 250 / 300mm NB CI/DI pipe, complete all as specified and directed by Engineer-in-Charge.
Supply only CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings of size 20mm (OD) complete all as specified and directed by Engineer-in-Charge.
Supply only CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings of size 25mm(OD) complete all as specified and directed by Engineer-in-Charge.
Supply only CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings of size 32mm (OD) complete all as specified and directed by Engineer-in-Charge.
Supply only GI pipe 40mm dia bore, medium grade with all fittings such as sockets, unions, bends, Tees, reducers, nipples etc complete all as specified and directed by Engineer-in-Charge.
Supply only GI pipe 50mm dia bore, medium grade with all fittings such as sockets, unions, bends, Tees, reducers, nipples etc complete all as specified and directed by Engineer-in-Charge.
Supply only GI pipe 80mm dia bore, medium grade with all fittings such as sockets, unions, bends, Tees, reducers, nipples etc complete all as specified and directed by Engineer-in-Charge.
Supply only GI pipe 100mm dia bore, medium grade with all fittings such as sockets, unions, bends, Tees, reducers, nipples etc complete all as specified and directed by Engineer-in-Charge.
Supply only 3-layer PP-R (Polypropylene random copolymer) of size 90 mm (OD) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings complete all as specified and directed by Engineer-in-Charge.
All as per item No. 45 here-in-before but of size 63 mm (OD)
All as per item No. 45 here-in-before but of size 32 mm (OD)
Taking up or down steel tubing and connections, including cleaning for refixing or taking credit for the following pipe sizes, complete all as specified and directed by Engineer-in-Charge.:-
15mm dia bore
20mm dia bore
25mm dia bore
40mm dia bore
50mm dia bore
80mm dia bore
100mm dia bore
Material and Labour for GI pipe of following sizes, medium grade with all fittings such as Sockets, Reducers, Unions, Tees, Nipples, Bends etc laid in trenches complete all as specified and directed :-
15mm dia bore
20mm dia bore
25mm dia bore
40mm dia bore
50mm dia bore
80mm dia bore
100mm dia bore
Material and Labour for GI pipe of the following pipe sizes, medium grade with all fittings such as Sockets, Reducers, Unions, Tees, Nipples, Bends etc fixed to walls / laid on floors etc complete all as specified and directed :-
40mm dia bore
50mm dia bore
80mm dia bore
100mm dia bore
Supplying and laying of CPVC pipes of size 25mm(OD) SDR 11 & Plain CPVC SDR 11 fittings in trenches / fixed to walls / laid on floors etc complete all as specified and directed by Engineer-in-Charge.
Supplying and laying of CPVC pipes of size 32mm(OD) SDR 11 & Plain CPVC SDR 11 fittings in trenches / fixed to walls / laid on floors etc complete all as specified and directed by Engineer-in-Charge.
Material and Labour for Ductile iron pipe (Conforming to IS: 8329-2000), Centrifugally Cast (Spun) Pressure Pipe with Socket and Spigot ends suitable for Push-on-Joint including jointing material, duly applied with Zinc Coating with finishing layer of Bitumen on external surfaces and Cement Motor Lining with Bituminous Seal Coat on internal surfaces complete of size 100mm bore class K-9 laid in trenches including taking out existing unserviceable CI / DI pipe of any description complete all as specified and directed by Engineer-in-Charge.
Material and labour for M.S. ERW Pipe P/E as Per IS:3589 Gr. 330, nominal bore 150 mm dia, medium (B) class with all fittings including cutting, welding and joining as per site requirement and applying two coats of synthetic enamel paint of approved colour over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
Material and labour for M.S. ERW Pipe P/E as Per IS:3589 Gr. 330, nominal bore 200 mm dia, 5mm thickness with all fittings including cutting, welding and joining as per site requirement and applying two coats of synthetic enamel paint of approved colour over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
Material and Labour for 3-layer PP-R (Polypropylene random copolymer) of size 90 mm (OD) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings including taking out existing unserviceable PP-R / GI pipe of any description complete all as specified and directed by Engineer-in-Charge.
All as per item No. 56.00 here-in-before but of size 63 mm (OD)
All as per item No. 56.00 here-in-before but of size 32 mm (OD)
Drilling and tapping cast iron water mains (in position) for branch connections of the internal dia 20mm and fixing Straight plain brass ferrules (or connecting screws) screwed both ends and fixed complete all as specified and directed by Engineer-in-Charge.
Cutting existing steel tubing and Screwing for alterations or additions (or lengthening screw on pipe to form connector) done in position without taking downfor the following pipe sizes, complete all as specified and directed :-
25mm dia bore
40mm dia bore
50mm dia bore
80mm dia bore
100mm dia bore
Supply and replace Cast Iron sluice valve of size 200mm dia bore, having pressure rating PN 1.6, double flanged, non-rising stainless steel spindle with iron wheel conforming to IS:14846-2000 with jointing material i.e. new rubber gasket, GI nuts, bolts & washers etc of suitable size including taking down existing old unserviceable sluice valve complete all as specified and directed by Engineer-in-Charge.
All as per item No. 61.00 here-in-before but of size 150mm dia bore
All as per item No. 61.00 here-in-before but of size 100mm dia bore
All as per item No. 61.00 here-in-before but of size 80mm dia bore
Supply and replace Cast Iron Non Return Valve (NRV) 200mm NB with flanged ends swing type / ball type as per site requirement, including replacement of necessary packing material, GI bolts, nuts and washers etc including taking out existing unserviceable NRV of any description complete all as specified and directed by Engineer-in-Charge.
All as per item No. 65.00 here-in-before but of size 150mm NB
All as per item No. 65.00 here-in-before but of size 100mm NB
All as per item No. 65.00 here-in-before but of size 80mm NB
Supply and replace Cast Iron foot valve of size 200mm NB, flanged end ball type/ swing type including replacement of necessary packing material, GI bolts, nuts and washers etc including taking out existing unserviceable foot valve of any description complete all as specified and directed by Engineer-in-Charge.
All as per item No. 69.00 here-in-before but of size 150mm NB
All as per item No. 69.00 here-in-before but of size 100mm NB
All as per item No. 69.00 here-in-before but of size 80mm NB
Supply & Fix Brass foot valve of size 50mm NB taking out existing unserviceable foot valve of any description complete all as specified and directed by Engineer-in-Charge.
Supply and fix Gun-metal gate valves for the following pipe sizes, with iron wheel head, screwed both ends for iron pipe including taking down existing unserviceable gate valve of any description complete all as directed:-
80mm dia NB
50mm dia NB
40mm dia NB
25mm dia NB
20mm dia NB
Supply and fix PP-R Gate valves (brass insert) of size 63mm(OD) as per requirement of the site complete all as specified and directed by Engineer-in-Charge.
Supply and fix PP-R Gate valves (brass insert) of size 32mm(OD) as per requirement of the site complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of CPVC ball valve of size 20mm (OD) complete all as specified and directed.
Supply and fix in replacement of CPVC ball valve of size 25mm (OD) complete all as specified and directed.
Supply and fix in replacement of CPVC ball valve of size 32mm (OD) complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep and getting out in any type soil for laying pipes etc, complete all as directed by Engineer-in-Charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm, complete all as directed by Engineer-in-Charge.
Removing excavated material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as directed by Engineer-in-Charge.
Material and labour for cutting of existing road / hard standing up to 15 cm depth for laying of pipes, and making good the disturbed surfaces by providing PCC 1:2:4 type B-1 after laying of pipes and returning filling of soil, complete all as specified and directed by Engineer-in-Charge. Note:- Excavation and earth work below road / hard standing shall be measured and paid under relevant items.
Material and labour constructing valve chamber of internal dimensions 1mtr x1mtr x1.2 mtrs with 100 mm thick PCC (1:4:8 ) type D-2 for foundation, brick walls built in cement mortar (1:4 ), PCC 1:2:4 type B1 for coping , rendering in cement mortar 1:4 , 15 mm thick internally and on exposed surfaces externally up to 15 cm above GL. Bottom PCC floor of the pit should be minimum 30 cms below the bottom surface of sluice valve flange to provide sufficient working space. The sluice valve and other fittings should be housed in center of the pit, the vertices of the pit should be in right angle and champhered .The top cover of the pit will be made out of 3mm MS sheet with angle iron frame made out of MS angle 50mm x 50 mm x 6 mm with MS hinges two Nos, and locking arrangements duly painted with two coats of water resistant synthetic enameled paint over one coat of red oxide primer, including demolition and taking out of existing broken valve chamber of any description complete all as specified and directed by Engineer-in-Charge.
Material and labour for brick masonry with sub class B bricks, straight or curved on plan exc 6m mean radius in cement mortar 1:6 complete all as specified by Engineer-in-Charge.
Material and labour for rendering 10mm thick cement plaster 1:6 on fair faces of brick work or concrete surfaces finished even and smooth (with out using extra cement) complete all as directed by Engineer-in-Charge.
Dismantling or removing of centrifugal coupled / monoblock electric pump set of any make and model, of capacity 75 HP to 100 HP from its installed position by disconnecting suction and delivery lines, fixing dummy plate to both suction & delivery pipe, disconnecting electrical cables, earth strips and dismounting the pump and motor from base channel for overhauling / repair / rewinding of motor etc and reinstalling back in its original position, checking alignment and testing on completion for satisfactory performance complete all as directed by Engineer-in-Charge. Note: Overhauling, re-winding and spare parts required for repair shall be measured and paid separately under relevant items of BOQ.
All as per Item No.87 here-in-before but capacity 40 HP to 50 HP.
All as per Item No.87 here-in-before but capacity 20 HP to 30 HP.
All as per Item No.87 here-in-before but capacity 10HP to 15 HP.
All as per Item No.87 here-in-before but capacity 5HP to 7.5 HP.
All as per Item No.87 here-in-before but capacity up to 3 HP.
Disconnecting the electric cable and water mains, lifting the submersible pump set of any make and model of capacity up to 5 HP along with column pipe and submersible cable from Open Well / UG Sump / Shallow well having depth up to 15 mtrs for carrying out repairs / rewinding / replacement of defective submersible cable / replacement of rusted column pipe and re-installing and reconnecting the water mains and electric connections and testing on completion for satisfactory performance complete all as directed by Engineer-in-Charge. Note: Overhauling, re-winding and spare parts required for repair shall be measured and paid separately under relevant items of BOQ.
Overhauling of pump set of any make and model by opening the pump and motor, replacing the worn out/defective spare parts, making good of shaft and shaft sleeve, cleaning internally, lubricating the rotating parts, re-assembling the pump and motor duly replacing all the packing material, worn out bolts, nuts, washers etc and testing for satisfactory performance of capacity 75HP to 100HP complete all as specified and directed by Engineer-in-Charge. Note: (i) Quoted rate shall deemed to be inclusive of necessary packing material, nuts, bolts & washers etc. (ii) Spare parts replaced shall be measured and paid separately under relevant items of BOQ.
All as per Item No.94 here-in-before but capacity 40 HP to 50 HP.
All as per Item No.94 here-in-before but capacity 20 HP to 30 HP.
All as per Item No.94 here-in-before but capacity 10HP to 15 HP.
All as per Item No.94 here-in-before but capacity 5HP to 7.5 HP.
All as per Item No.94 here-in-before but capacity up to 3 HP.
All as per Item No.94 here-in-before but open well Submersible pump set of capacity up to 5HP
Shifting of pump set with motor of any type and capacity from any pump house located under AoR of GE (U-II) to civil workshop for repair / rewinding and bringing back with suitable mode of transport complete all as directed by Engineer-in-Charge.
Cutting and removing burnt out winding from electric motor of any make and model and rewinding with super enameled copper winding wire of existing gauge and number of turns including necessary insulation, varnishing, heating etc and testing for satisfactory performance of capacity 75HP to 100HP complete all as directed by Engineer-in-Charge.
All as per Item No.102 here-in-before but capacity 40 HP to 50 HP.
All as per Item No.102 here-in-before but capacity 20 HP to 30 HP.
All as per Item No.102 here-in-before but capacity 10HP to 15 HP.
All as per Item No.102 here-in-before but capacity 5HP to 7.5 HP.
All as per Item No.102 here-in-before but capacity up to 3 HP.
Cutting and removing burnt out winding from submersible electric motor of any make and model and rewinding with water proof poly wrapped copper winding wires of existing gauge and number of turns and testing for satisfactory performance of capacity up to 5HP complete all as specified and directed by Engineer-in-Charge.
Supply only the following spare parts suitable for existing centrifugal / monoblock pump sets and motors of any make and model as per site requirement, complete all as specified and directed by Engineer-in-Charge. :-
Roller bearing suitable for 75 HP to 100 HP pump/motor
Ball bearing DE/NDE suitable for 75 HP to 100 HP pump/motor
Roller bearing suitable for 40 HP to 60 HP pump/motor
Ball bearing DE/NDE suitable for 40 HP to 60 HP pump/motor
Ball bearing DE/NDE suitable for 20 HP to 30 HP pump/motor
Ball bearing DE/NDE suitable for 10 HP to 15 HP pump/motor
Ball bearing DE/NDE suitable for 5 HP to 7.5 HP pump/motor
Ball bearing DE/NDE suitable for up to 3 HP pump/motor
Shaft sleeve suitable for 60 HP to 100 HP pump set
Shaft sleeve suitable for 20 HP to 50 HP pump set
Metallic hub for jaw / star coupling suitable for 60 HP to 100 HP pump set
Metallic hub for jaw / star coupling suitable for 20 HP to 50 HP pump set
Elastomeric insert (spider) for jaw / rubber star coupling suitable for 60 HP to 100 HP pump set
Elastomeric insert (spider) for jaw / rubber star coupling suitable for 20 HP to 50 HP pump set
Gland plate with gland rope suitable for 60 HP to 100 HP pump
Gland plate with gland rope suitable for 20 HP to 50 HP pump
Cable terminal plate suitable for 60 HP to 100 HP motor
Cable terminal plate suitable for 20 HP to 50 HP motor
External fan plastic body suitable for up to 15 HP motor
External fan plastic body suitable for 20 HP to 50 HP motor
External fan plastic body suitable for 60 HP to 100 HP motor
CI Impeller with key suitable for 10 HP to 15 HP pump
CI Impeller with key suitable for 5 HP to 7.5 HP pump
CI Impeller with key suitable for up to 3 HP pump
Supply only the following spare parts suitable for existing open well submersible pump and motor set of capacity up to 5HP of any make and model as per site requirement, complete all as specified and directed by Engineer-in-Charge. :-
SS Rotor Sleeve
GM Housing Bush
Thrust bearing
Stud, Nut & Bolt set
Impeller shaft
SS Impeller
Shaft sleeve
Neck Ring set
SS Coupling assy with key
Supply and replace pressure gauge of size 100mm dial, 0-10 Kg/CM2, complete all as specified and directed.
Material and labour for preparation of old painted surfaces of pump sets for pump set of capacity 75 HP to 100 HP and painting to electric pump and motor set and base frame with two coats of synthetic enameled spray paint of approved colour as per standard MES colour coding complete all as specified and directed by Engineer-in-Charge .
All as per Item No.112 here-in-before but capacity 40 HP to 50 HP.
All as per Item No.112 here-in-before but capacity 20 HP to 30 HP.
All as per Item No.112 here-in-before but capacity 10HP to 15 HP.
All as per Item No.112 here-in-before but capacity 5HP to 7.5 HP.
All as per Item No.112 here-in-before but capacity up to 3 HP.
Supply, laying and connecting PVC insulated and PVC Round Sheathed, Multicore Annealed Bare Copper Conductor (flexible) industrial cable of size 50 sqmm, 3 core for Voltage Grade 1100 Volt, Conforming to IS 694 : 2010 including taking down existing unserviceable cable of any description complete all as specified and directed by Engineer-in-Charge.
Supply, laying and connecting PVC insulated and PVC Round Sheathed, Multicore Annealed Bare Copper Conductor (flexible) industrial cable of size 25 sqmm, 3 core for Voltage Grade 1100 Volt, Conforming to IS 694 : 2010 including taking down existing unserviceable cable of any description complete all as specified and directed by Engineer-in-Charge.
Supply , laying and connecting Flat Three Core PVC Insulated & PVC Sheathed copper conductor Industrial Cable of size 16 sqmm, 3 core for Submersible Pump Motors 1100 Volt, conforming to IS 694 including taking down existing unserviceable cable of any description complete all as specified and directed by Engineer-in-Charge.
Supply , laying and connecting Flat Three Core PVC Insulated & PVC Sheathed copper conductor Industrial Cable of size 10 sqmm, 3 core for Submersible Pump Motors 1100 Volt, conforming to IS 694 including taking down existing unserviceable cable of any description complete all as specified and directed by Engineer-in-Charge.
Supply , laying and connecting Flat Three Core PVC Insulated & PVC Sheathed copper conductor Industrial Cable of size 4 sqmm, 3 core for Submersible Pump Motors 1100 Volt, conforming to IS 694 including taking down existing unserviceable cable of any description complete all as specified and directed by Engineer-in-Charge.
M&L for preparing new or previously untreated steel surfaces of water pipe lines of any size, in any position, with two coats of synthetic enameled paint over one coat of red oxide primer with & including marking direction & name of feeder, complete all as directed by Engineer-in-Charge.
Material and labour for Mild Steel base frames for pump sets, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of Anti Vibration Mounting pads made out of composite elastomeric material and metal housing having skid protected elastomeric base suitable for floor installation of centrifugal coupled pump and motor set of capacity 50 HP to 100 HP without anchoring or grouting for safeguarding equipment against vibration, longitudinal and transverse stiffness complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of Anti Vibration Mounting pads made out of composite elastomeric material and metal housing having skid protected elastomeric base suitable for floor installation of centrifugal coupled pump and motor set of capacity 15 HP to 40 HP without anchoring or grouting for safeguarding equipment against vibration, longitudinal and transverse stiffness complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:3:6 type C2 using 40mm graded stone aggregate as in foundation, base concrete, hard standing etc complete all as specified and directed by Engineer-in-Charge.
M&L for PCC 1:2:4 type B1 using 20mm graded stone aggregate as in foundation, base concrete, hard standing etc complete all as specified and directed by Engineer-in-Charge.
Material and labour for Mild Steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed by Engineer-in-Charge.
Taking down existing unserviceable spare parts and supply and replace following spare parts in AC, 3 Phase, 415 V, 50 Hz motor control panels complete all as specified and directed by Engineer-in-Charge.:-
Power contactor suitable for existing star-delta starter of 75 HP motor.
Power contactor suitable for existing star-delta starter of 30 - 40 HP motor.
Power contactor suitable for existing star-delta starter of 10 - 15 HP motor.
Thermal Overload Relay suitable for existing star-delta starter of 75 HP motor.
Thermal Overload Relay suitable for existing star-delta starter of 30 - 40 HP motor.
Thermal Overload Relay suitable for existing star-delta starter of 10 - 15 HP motor.
Electronic Timer 3 - 30 sec
LED indication lamp Red/Yellow/Blue/Green colour
Push Button Switch for ON/OFF operations Red / Green colour
Digital Voltmeter 0 - 500 V range
Digital Ammeter 0 - 100 A range
Supply and fix MCCB, 250 A, 36 KA, 4 pole, 415 V, 50 Hz with fixed thermal and magnetic release including taking down unserviceable MCCB of any description complete all as specified and directed by Engineer-in-Charge.
Supply and fix MCCB, 100 A, 25 KA, 4 pole, 415 V, 50 Hz with fixed thermal and magnetic release including taking down unserviceable MCCB of any description complete all as specified and directed by Engineer-in-Charge.
Supply and fix MCB, 63 A, 10 KA, 4 pole, 'C' Curve, 415 V, 50 Hz including taking down unserviceable MCB of any description complete all as specified and directed by Engineer-in-Charge.
Supply and fix MCB, 32 A, 10 KA, 2 pole, 'C' Curve, 415 V, 50 Hz including taking down unserviceable MCB of any description complete all as specified and directed by Engineer-in-Charge.
Supply, installation, testing and commissioning of Soft Starter for soft starting and stopping of 55KW / 75 HP, 3 phase, 415 V, 50 Hz, AC induction motor coupled with centrifugal pump with provision of bilt-in bypass contactor, essential motor protections against instantaneous over current, bypass overload, motor overload, phase imbalance, phase loss, phase sequence, excess start time, motor thermostat, supply fault, shorted SCR and LED indications for Ready / Tripped, Running/Starting-Stopping, Fault Code etc including taking down existing unserviceable starter of any description complete all as specified and directed by Engineer-in-Charge.
All as per item No. 135.00 here-in-before but for 30 KW / 40 HP
All as per item No. 135.00 here-in-before but for 22 KW / 30 HP
Supply and fix fully Automatic Star Delta Starter in Sheet Steel enclosure / Panel mounting type suitable for 15 HP, AC, 3 Phase, 415 V, 50Hz induction motor incorporating Heavy Duty 4 Pole Contactor with wide band operating coil, Overload relay for motor protection and Electronic Star Delta Timer including taking down existing unserviceable starter of any description complete all as specified and directed by Engineer-in-Charge.
Supply and fix DOL starter in Sheet Steel Enclosure incorporating Heavy Duty 4 Pole Contactor with wide band operating coil, Overload relay with manual re-set and yellow flag for trip indication suitable for up to 7.5 HP, AC, 3 Phase, 415 V, 50Hz induction motor including taking down existing unserviceable starter of any description complete all as specified and directed by Engineer-in-Charge.
Supply, laying, connecting and testing of XLPE insulated, PVC sheathed, galvanized steel strip or wire armored, stranded aluminium conductor cable of size 50 Sqm, 3.5 core including taking down of existing unserviceable cable of any description complete all as specified and directed by Engineer-in-Charge.
All as per item No. 140.00 here-in-before but of size 25 Sqm, 4 core
All as per item No. 140.00 here-in-before but of size 16 Sqm, 4 core
Supply and fixing LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamps including taking down existing unserviceable flood light of any description complete all as specified and directed by Engineer-in-Charge.
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections, one twin core cable flat or circular of size 10 sqmm stranded conductor including taking down existing unserviceable cable of any description complete all as specified and directed by Engineer-in-Charge.
Labour only for attending Starter Panel / LT Panel/ Motor complaints, checking fault in bus bars/ control wiring / starter, cables etc and rectifying the fault by replacing defective spare parts by deploying technician / electrician etc as per site requirement at any time on any day including Sunday and Holiday complete all as specified and directed by Engineer-in-Charge. Note: Spare parts required shall be measured and paid separately. However, cost of minor spare parts and consumables costing up to Rs. 500 each shall deemed to be included in the quoted rate. Contractor should arrange the technician within 02 hours of intimation of complaint by JE E/M / Engineer-in-Charge and the complaint should be rectified as soon as possible but not later than 08 hours from the time of intimation. If contractor fails to arrange the technician and rectify the complaint within the specified time, a penal recovery of Rs. 500 per hour of delay beyond the specified time limit will be made from contractor's dues.
Material and labour for Double wall corrugated HDPE pipe, ISI marked of outer dia 50mm, inner dia 38mm with smooth internal and profiled external surface, non-pressure type, laid in trenches/floors/duct or fixed on walls /pole including all connections, accessories like socket, couplers, bends, etc for protection of LT cable XLPE grade 1100 volts complete all as specified and directed by Engineer-in-Charge.
Supply and spread clean dry river sand in trenches for cushioning of cable complete all as specified and directed by Engineer-in-Charge. Note: Punned down thickness only shall be measured for the purpose of payment.
Supply and laying in trenches, un-reinforced precast concrete cable cover, ISI marked, Class LV, Type I, flat, size 250 mm x 150mm x 40mm for cable protection in trenches complete all as specified and directed.
Material and labour for Surface dressing not exc 15cm deep in any type of soil and site clearance including cutting and removing of plants/bushes, levelling of surface area, throw wastage material out of fencing area/ compound wall up to 50m distance at sub station areas / pump House areas complete all as specified and as directed by Engineer-in-Charge.
Supply and fix Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 20mm-210gms) including taking down old existing unserviceable float valve of any description complete all as specified and directed by Engineer-in-Charge
Supply and fix Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 25mm-455gms) including taking down old existing unserviceable float valve of any description complete all as specified and directed by Engineer-in-Charge
SCHEDULE OF CREDIT Note :- Amount of Rs. 2,26,960.00 indicated in Tender Documents as Schedule of Credit shall be deducted from the total quoted amount of BOQ.
G Srinivas Rao (BID ID -3397111)
K.ADITYA ENGINEERING CONTRACTORS (BID ID -3397649)
UV POWER TECH (BID ID -3397392)
SATYAMEGHA ENGINEERS (BID ID -3396687)
MERIDIAN CONSTRUCTIONS PRIVATE LIMITED (BID ID -3397841)
M/s KAMADHENU ENGINEERING CONSTRUCTIONS (BID ID -3397017)
ANJALI ENTERPRISES (BID ID -3397342)
M/S CHANDRA ENGINEERS AND CONTRACTORS (BID ID -3397303)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .