Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46,471.85Admitted-Fee/PreQual/Technical/Finance KOOMBRA POOLAKKAPARAMBIL H MALA PATTITHARA GRAMA PANCHAYATH | PALAKKAD | KERALA | 678001 | L1 | Admitted-Fee/PreQual/Technical/Finance |
| Sl No | Description | Qty | Unit | MUHAMMED ASHIF.K.P L1 |
|---|---|---|---|---|
| 1.00Electrical Work | ||||
| 1.00 | OD347658/2025-2026:Supply and conveyance charges for Monoblock 3HP, Horizontal type open well submersible motor pump set having discharge of 12lps to 4 lps against total head of 20 meter, cast iron/bronze impeller, carbon steel / stain less steel shaft, ( Kirloskar make- KOS-318+/CRI CSS-18/crompton- greavesOWNH32Z-27U) or suitable for 415 V, 50 Hz, 3 phase AC supply, | 1 | each | 34,327.5 ₹34,327.5 Lowest |
| 1.00 | 90.14.28.14:S & F Motor starters of the following ratingsSubmersible pump controllers with ammeter,TPMCB for three phase 5 to 7.5HP submersible motor pumps (DOL) | 1 | each | 4,061.14 ₹4,061.14 Lowest |
| 1.00 | 90.14.24.1:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.1 KVAr, 3 phase, 440 V, delta connected Metalised Poly Propylene Capacitor, Cylinderical Type, suitable for direct connection to motors. | 1 | each | 287.85 ₹287.85 Lowest |
| 1.00 | 90.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43) | 1 | each | 6,605.1 ₹6,605.1 Lowest |
| 1.00 | 2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps | 1 | each | 1,190.26 ₹1,190.26 Lowest |
Tender Value
₹46,472
EMD Value
₹1,162
Closing Date
23 May 2026, 12:00 pmClosed
The Assistant Engineer
Office of the Assistant Engineer, LID EW Section, Pattithara Grama Panchayat
Annual Plan-Electrical Work - Supply of Motor Pump set Menothnjalil DWS Pattithara Grama Panchayath-Supply of Motor Pump set Menothnjalil DWS Pattithara Grama Panchayath-General Electrical Work
2026_LSGD_850732_7
01/AE/LID EW/PTRA/2026-27
Open Tender
Civil Works - Buildings
Item Rate
150 days
Pattithara Grama Panchayat
Please refer Tender documents.
8 documents required · 8 mandatory
₹335
Yes
₹1,162
Yes
25 Jun 2026
14 May 2026
23 May 2026
14 May 2026
23 May 2026
14 May 2026
14 May 2026 - 20 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Electrical Work | |||||
| 1.001 | OD347658/2025-2026:Supply and conveyance charges for Monoblock 3HP, Horizontal type open well submersible motor pump set having discharge of 12lps to 4 lps against total head of 20 meter, cast iron/bronze impeller, carbon steel / stain less steel shaft, ( Kirloskar make- KOS-318+/CRI CSS-18/crompton- greavesOWNH32Z-27U) or suitable for 415 V, 50 Hz, 3 phase AC supply, | - | each | - | - |
| 1.002 | 90.14.28.14:S & F Motor starters of the following ratingsSubmersible pump controllers with ammeter,TPMCB for three phase 5 to 7.5HP submersible motor pumps (DOL) | - | each | - | - |
| 1.003 | 90.14.24.1:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.1 KVAr, 3 phase, 440 V, delta connected Metalised Poly Propylene Capacitor, Cylinderical Type, suitable for direct connection to motors. | - | each | - | - |
| 1.004 | 90.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43) | - | each | - | - |
| 1.005 | 2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps | - | each | - | - |
stage.html
html • 0.01 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.47 MB
ig.pdf
Other Document • 0.24 MB
affida.pdf
Tender Documents • 0.24 MB
BOQ_1437658.xls
BOQ • 0.30 MB
sbd.pdf
Other Document • 0.97 MB
pa.pdf
Tender Documents • 0.26 MB
fot.pdf
Tender Documents • 0.25 MB
epay.pdf
Other Document • 0.24 MB
time.pdf
PDF • 0.18 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .