University Engineer
office of the University Engineer Kariavattom campus
Air Conditioning Works
2022_KU_510081_1
UE/DB/ (e-GP)/E12/2022-2023
Open Tender
Electrical Works
Item Rate
50 days
kariavattom
Please refer Tender documents.
8 documents required · 8 mandatory
₹2,625
₹50,000
3 Dec 2022
29 Sept 2022
21 Oct 2022
29 Sept 2022
19 Oct 2022
29 Sept 2022
29 Sept 2022 - 19 Oct 2022
Amount
HIGH SIDE
od135000/2022_2023 : 19 TR AHU 8000 CFM @50mm ESP SUITABLE FOR VRF - VPCL<br>The supply, freight, loading, unloading of Factory buit and tested Double Skin Air Handling units with Powder coated Inner and outer .6 mm 120 GSM GSS sheet 40 mm thick PUF insulation of 40 kg density, sandwich panels with pre plasticised finish, extruded aluminum frame work, Thermal breaks, with Fan section, coil section, filter section, insulated SS drain pan, with plug fans, backward curved DIDW blower, high efficiency TEFC motor, IE 2, VFD driven, Intertwined Cooling coil copper tube size 3/8 inch, aluminum fins min. 450 fins/mtr, 3 distributers, 3 Expansion Device of 6.5 TR capacity each required controls and panels with relays and switches, 10 mm thick synthetic media filter with frame. 90% efficiency down to 10 micron, inspection lamps, Vibration Isolators, Inlet and outlet volume control dampers, fire dampers at outlet with micro switch and wiring to shut down the AHU. The required sandwich panels, Motor assembly, Motor base, Cooling Coil and expansion devices. Commissioning filter sets and all other standard accessories.<br>19 TR Floor Mounted AHU 8000 CFM@50mm ESP Eurovent Certified)<br>(Daikin/Mitsubishi/Fujitsu General/VTS)
od135001/2022_2023 : VRF/VRV OUT DOOR UNIT- 24 HP(12HP+12HP) - VPCL <br>Supply, Freight, Loading, unloading of direct expansion type VRV/VRF 20HP outdoor units (VRT/PET Technology with Automatic Phase Sequence Controller) of said capacity complete with condenser, fans, hermetically sealed dual/triple scroll compressor operating on R410A, controls and control wiring and wired touch screen remote control unit with rubber pads<br>Each module of outdoor unit must have at least 50 % of Variable compressor which can work on Part load Suitable to operate at heat load proportional to indoor requirement. The ODU must deliver COP of minimum 4.7 at 50 % load.<br>Safety Features :-<br>(a.)High Pressure Switch. (b.)Fuse.<br>(c.)Fan Drive OLP. (d.)Fusible plug<br>(e.)OLR (f.)OLP for Inverter/digital.<br>(g.)Single Phase preventer<br>With necessary mounting at site with full insurance coverage during factory to site or for any other contingencies (Daikin/Mitsubishi/Fujitsu General)
od135002/2022_2023 : VRF/VRV OUT DOOR UNIT- 32HP ODU (16HP+16HP) - VPCL <br>Supply, Freight, Loading, unloading of direct expansion type VRV/VRF 20HP outdoor units (VRT/PET Technology with Automatic Phase Sequence Controller) of said capacity complete with condenser, fans, hermetically sealed dual/triple scroll compressor operating on R410A, controls and control wiring and wired touch screen remote control unit with rubber pads<br>Each module of outdoor unit must have at least 50 % of Variable compressor which can work on Part load Suitable to operate at heat load proportional to indoor requirement. The ODU must deliver COP of minimum 4.7 at 50 % load.<br>Safety Features :-<br>(a.)High Pressure Switch. (b.)Fuse.<br>(c.)Fan Drive OLP. (d.)Fusible plug<br>(e.)OLR (f.)OLP for Inverter/digital.<br>(g.)Single Phase preventer<br>With necessary mounting at site with full insurance coverage during factory to site or for any other contingencies (Daikin/Mitsubishi/Fujitsu General)
od135003/2022_2023 : VRF 1Tr Hi wall type indoor unit - VPCL<br>Supply,installation,testing and commissioning of minimum capacity VRV/VRF Highwall type Indoor unit equipped with washable synthetic mediapre-filter, fan section with low noise fan/dynamically balanced blower, multispeedmotor, coi lsection with DX copper coil, electronic expansion valve, outercabinet, cordless remote control, drain pan, necessary accessories etc., suitable for operation on 230V±10%, 50Hz, single phase ACsupply, complete as required. The unit shall have automatic force shutdown provision in case of fire on receiving signal from control panel<br>(Daikin/Mitsubishi/Fujitsu General)
od135004/2022_2023 : VRF 1.5 Tr Hi wall type indoor unit - VPCL<br>Supply,installation,testing and commissioning of minimum capacity VRV/VRF Highwall type Indoor unit equipped with washable synthetic mediapre-filter, fan section with low noise fan/dynamically balanced blower, multispeedmotor, coi lsection with DX copper coil, electronic expansion valve, outercabinet, cordless remote control, drain pan, necessary accessories etc., suitable for operation on 230V±10%, 50Hz, single phase ACsupply, complete as required. The unit shall have automatic force shutdown provision in case of fire on receiving signal from control panel<br>(Daikin/Mitsubishi/Fujitsu General)
od135005/2022_2023 : VRF 2TR Hi wall type indoor unit - VPCL<br>Supply,installation,testing and commissioning of minimum capacity VRV/VRF Highwall type Indoor unit equipped with washable synthetic mediapre-filter, fan section with low noise fan/dynamically balanced blower, multispeedmotor, coi lsection with DX copper coil, electronic expansion valve, outercabinet, cordless remote control, drain pan, necessary accessories etc., suitable for operation on 230V±10%, 50Hz, single phase ACsupply, complete as required. The unit shall have automatic force shutdown provision in case of fire on receiving signal from control panel<br>(Daikin/Mitsubishi/Fujitsu General)
od135006/2022_2023 : VRF 4way 2Tr Cassette type indoor unit -VPCL<br>Supply, installation, testing and commissioning of minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multi speed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cordless remote control etc., suitable for operation on single phase 230V± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from control panel <br>(Daikin/Mitsubishi/Fujitsu General)
od135007/2022_2023 : VRF 4way 3TR Cassette type indoor unit -VPCL<br>Supply, installation, testing and commissioning of minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multi speed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cordless remote control etc., suitable for operation on single phase 230V± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from control panel<br>(Daikin/Mitsubishi/Fujitsu General)
od135008/2022_2023 : VRF/VRV Ducted 8.5TR Low Noise Low Velocity Ducted Unit - VPCL<br>Supply, installation, testing and commissioning of low velocity, low noise ducted units suitable for rooms with high sensitive microphone, minimum capacity 8.5TR and external static pressure VRF/VRV ceiling mounted ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multi speed motor, coil section with DX copper coil, electronic expansion valve, corded remote control, outer cabinet, vibration isolators, drain pan, other necessary supports etc., suitable for operation on single phase AC supply 230V±10%, 50Hz complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from Control Panel<br>Daikin/Mitsubishi/Fujitsu General
od135009/2022_2023 : Supply,Installation, testing and commissioning of AHU KIts<br>(Mitsubishi/Fujitsu General)
od135010/2022_2023 : Decorative Panel for Cassette type Indoor Unit suitable to the ceiling of the rooms
od135012/2022_2023 : Supply, Installation and commissioning of Refnet joints
LOW SIDE
od135014/2022_2023 : Installation, Lifting, Shifting, positioning and commissioning charges for AHU of 19 TR
od135015/2022_2023 : Installation, Lifting, Shifting, positioning and commissioning charges of ODUs
od135016/2022_2023 : Installation, Lifting, Shifting, positioning and commissioning charges of 8.5TR Ductable Unit
od135017/2022_2023 : Installation and commissioning charges of high wall split
od135018/2022_2023 : Lifting, Installation, positioning and commissioning charges for Cassette split
od135019/2022_2023 : Supply and Installation of Heavy duty Out door Metal frame
od135021/2022_2023 : Charges for Installation of Expansion valve
od135022/2022_2023 : Supply & installation of 18G, hard drawn copper refrigerant piping for AHU duly insulated with closed cell elastomeric nitrile rubber insulation, complete with elbows, T joints, sleeves etc., with GSS slotted rail supporting arrangement and GI clamp for individual pipes.The piping to be duly insulated with minimum 19mm thick closed cell elastomeric nitrile rubber insulation for suction and minimum 13mm thick for discharge. Consider Suction and discharge as one.
od135023/2022_2023 : Drain Pipe 40mm dia<br>Supply & installation of PVC drain piping and insulated with 9mm thick<br>insulation of closed cell elastomeric nitrile rubber insulation.
od135024/2022_2023 : Control Cable<br>Supply & Installation of Communication cable between indoor and<br>outdoor units in PVC conduit and accessories as required.<br>(RR Kabel/Polycab/V-Guard)
od135037/2022_2023 : Supply and installation of Control panel and micro processer based temperature control system with sequential controller with Auto Manual<br>control panel.
AIR DISTRIBUTION SYSTEM
od135025/2022_2023 : 24G Ducting - VPCL<br>Supply and installation of Factory / Site fabricated, Rectangular sheet metal GSS ducts of grade 120 GSM confirming to latest IS-655 & 277 of following sizes as per drawing, complete with necessary supports using threaded rods.<br>(JINDAL/TATA/SAIL)
od135026/2022_2023 : 22G Ducting - VPCL<br>Supply and installation of Factory / Site fabricated, Rectangular sheet metal GSS ducts of grade 120 GSM confirming to latest IS-655 & 277 of following sizes as per drawing, complete with necessary supports using threaded rods.<br>(JINDAL/TATA/SAIL)
od135027/2022_2023 : 20G DUCTING - VPCL<br>Supply and installation of Factory / Site fabricated, Rectangular sheet metal GSS ducts of grade 120 GSM confirming to latest IS-655 & 277 of following sizes as per drawing, complete with necessary supports using threaded rods.(JINDAL/TATA/SAIL)
od135028/2022_2023 : Supply & fixing of 10 mm thick acoustic nitrile rubber insulation with<br>adhesive (Kflex/ALP Aeroflex/Paramount)
od135029/2022_2023 : Supply & fixing of 13 mm thick nitrile rubber insulation with adhesive<br>(Kflex/ALP Aeroflex/Paramount)
od135030/2022_2023 : Supply & fixing of 10 mm thick nitrile rubber insulation with adhesive<br>(Kflex/ALP Aeroflex/Paramount)
od135032/2022_2023 : Supply and intallation of Factory Fabricated Flexible canvas connection interconnecting the indoor and supply air ducts as per the requirement<br>with all accessories required for complete installation.
od135033/2022_2023 : Supply and installation of FRESH AIR INTAKE, FAL(FAL-Fresh Air Louver) + FAD(Fresh Air Duct) + VCD(Volume Control Damper). 450x300
od135034/2022_2023 : LINEAR BAR GRILLE FOR RETURN<br>Supply and installation of linear bar grille for return air on ceiling with detachable screws and mounting
od135035/2022_2023 : MS COLLER DAMPER - VPCL<br>Supply and installation superior quality MS Coller damper including all accessories
od135036/2022_2023 : DIFFUSERS- VPCL<br>Supply and installation of diffusers including all accessories - COSMIC
od154137/2022_2023 : Isowall panel air tight box of suitable size for mounting indoor unit, Iso wall panels with cam lock system of 50 mm thickness made from minimum 0.6mm powder coated sheet and sandwiched over 40+_2 kg/m3 layer of Rigid CFC free Closed cell polyurethane foam<br>Approved make - Lloyd/Pearson
Comprehensive Maintenance Contract
od135486/2022_2023 : Comprehensive Maintenance Contract Charges for air conditioners the fifth year, Rate inclusive of all labour charges, spares, consumables, wear and tear items, all fusible items, timely fulfillment of all statutory norms . Break down calls to be attended within 12 working hours. Payment of CMC charges shall be on pro-rata quarterly basis after completion of each quarter. Penalty for period in which the air conditioner is out of order in excess of 72 hours, shall be @Rs.1500/-(Rupees One Thousand Five Hundred Only) per 24 hours for each air conditioner separately from the time of breakdown. The value of the CMC Charges for the fifth year to be quoted in Rupees. The Percentage of hike in CMC charges to the fifth year from the fourth year shall be applicable for the future period with respect to consecutive years till useful/economic life of the equipment. Details of the percentage of hike to be filled as per annexure (Rate only)
od192761/2022_2023 : Comprehensive Maintenance Contract Charges for air conditioners for the fourth year, Inclusive of all labour charges, spares, consumables, wear and tear items, all fusible items, timely fulfilment of all statutory norms . Break down calls to be attended within 12 working hours. Payment of CMC charges shall be on pro-rata quarterly basis after completion of each quarter. Penalty for period in which the Air Conditioner is out of order in excess of 72 hours, shall be @Rs.1500/-(Rupees One Thousand Five Hundred Only) per 24 hours for each air conditioner separately from the time of break down, The value of CMC Charges are to be quoted in terms of rupees, further details of the CMC charges and percentage(tender value) to be filled as per annexure (Rate Only)
INTIMATE REFRIGERATION AND AIR CONDITIONS
Bidder Name
INTIMATE REFRIGERATION AND AIR CONDITIONS
cool master
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_730667.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .