| 1 | L1₹15.7 LAccepted-AOC | L1 | Accepted-AOC lowest | |
| 2 | L2₹20.0 L+₹1.5 L (8.15%)Rejected-Finance 5B FF NAND VIHAR AZAD NAGAR NEAR GODARA PETROL PUMP HISAR HARYANA 125001 | HISAR | HARYANA | 125001 | L2 | Rejected-Finance other than lowest | |
| 3 | L3₹21.6 L+₹3.1 L (17.0%)Rejected-Finance | L3 | Rejected-Finance other than lowest | |
| 4 | L4₹22.8 L+₹4.4 L (23.6%)Rejected-Finance 195 MAHESH NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L4 | Rejected-Finance other than lowest | |
| 5 | L5₹25.6 L+₹7.2 L (38.8%)Rejected-Finance | L5 | Rejected-Finance other than lowest |
| Sl No | Description | Qty | Unit | SUN MANN ENGINEERS L2 | PARDEEP CONSTRUCTION COMPANY L3 | Raman Electric Trading Co L4 | R G ENTERPRISES L6 | Durga Electricals L5 | JASSI TRADERS L7 | M/S SEALINE BUILDERS L1 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00Sch 'A' | ||||||||||
| 1.01 | Taking down existing street light fittings of any type/size/capacity fixed in any position i.e. on wall/ pole/ watch tower refixing the fitting in its original position after repairs complete all as specified and directed.
Note:-Spares shall be measured and paid separately under item No 08 & 09. | 190 | Each | 1 ₹190 Lowest | 150 ₹28,500 | 100 ₹19,000 | 50 ₹9,500 | 10 ₹1,900 | 500 ₹95,000 | 5 ₹950 |
| 2.00 | S&F in replacement for New generation energy saving and environmental friendly long life LED street light capacity 45 watts colour temp 6500K lumen effeciency 100lm/W made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having bottom opening separate driver compartment with IP66 protection and impact resistance of IK08 with pre wired and necessary mounting arrangementsnd provision of 2.5 sqmm three core copper conductor cable multi stranded from fitting to security light pole and taking down old unserviceable Street Light Fitting form Electric Pole of any description complete all as specified and directed. | 85 | Each | 1,200 ₹1,02,000 Lowest | 1,240 ₹1,05,400 | 1,360 ₹1,15,600 | 1,750 ₹1,48,750 | 1,200 ₹1,02,000 Lowest | 1,600 ₹1,36,000 | 1,400 ₹1,19,000 |
| 3.00 | As per Item No.02 above but Street Light fitting of 60 Watt complete all as specified and directed. | 76 | Each | 1,200 ₹91,200 Lowest | 1,800 ₹1,36,800 | 1,950 ₹1,48,200 | 2,300 ₹1,74,800 | 1,400 ₹1,06,400 | 2,200 ₹1,67,200 | 1,630 ₹1,23,880 |
| 4.00 | As per Item No.02 above but Street Light fitting of 90 Watt complete all as specified and directed. | 90 | Each | 2,500 ₹2,25,000 | 2,500 ₹2,25,000 | 2,450 ₹2,20,500 | 3,150 ₹2,83,500 | 2,200 ₹1,98,000 Lowest | 3,000 ₹2,70,000 | 2,400 ₹2,16,000 |
| 5.00 | S&F in replacement of LED flood light fitting for High Mast light of 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection,with impact and corrosion resistant complete including taking down unserviceable flood light fittings complete all as specified and directed. | 16 | Each | 3,000 ₹48,000 | 3,500 ₹56,000 | 3,300 ₹52,800 | 4,650 ₹74,400 | 4,000 ₹64,000 | 4,700 ₹75,200 | 2,800 ₹44,800 Lowest |
| 6.00 | S&F in replacement of LED flood light fitting for High Mast light of 150 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection,with impact and corrosion resistant complete including taking down unserviceable flood light fittings complete all as specified and directed. | 18 | Each | 3,500 ₹63,000 | 4,500 ₹81,000 | 4,300 ₹77,400 | 5,650 ₹1,01,700 | 4,000 ₹72,000 | 3,900 ₹70,200 | 3,200 ₹57,600 Lowest |
| 7.00 | S&F in replacement of copper conductor cable 3 core ,2.5 Sqmm, 1100 volts multistranderd PVC insulated weather proof, sheathed heavy duty ISI marked drawing through 20mm dia PVC pipe/conduit from LED street light fitting to junction box with proper connection with thimbles as per site requirement complete all as specified and directed. | 600 | RM | 65 ₹39,000 | 45 ₹27,000 | 69 ₹41,400 | 80 ₹48,000 | 40 ₹24,000 Lowest | 120 ₹72,000 | 65 ₹39,000 |
| 8.00 | Supply and fixing in replacement of driver suitable for any type of street light 45W/60W/90W complete all as specified and directed. | 90 | Each | 320 ₹28,800 | 125 ₹11,250 | 150 ₹13,500 | 450 ₹40,500 | 180 ₹16,200 | 650 ₹58,500 | 120 ₹10,800 Lowest |
| 9.00 | Supply and fixing in replacement of Surge protection device suitable for any type of street light 45W/60W/90W complete all as specified and directed. | 100 | Each | 90 ₹9,000 Lowest | 170 ₹17,000 | 150 ₹15,000 | 250 ₹25,000 | 100 ₹10,000 | 150 ₹15,000 | 100 ₹10,000 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
24 Nov 2025, 6:00 pmClosed
Garrison Engineer Ludhiana
Garrison Engineer Military Engineer Services Near Jagraon Bridge Ludhiana-141001 (Punjab)
Repair/replacement of street lights, security lights, earthing infrastructure and LT panels and connected E/M items at Dholewal Mil Complex under GE Ludhiana
2025_MES_735641_1
GE/LDH-54/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Dholewal Mil Complex
As per NIT and Tender documents
9 documents required · 9 mandatory
₹500
GE Ludhiana
₹70,000
Yes
24 Dec 2025
16 Oct 2025
26 Nov 2025
16 Oct 2025
24 Nov 2025
6 Nov 2025
16 Oct 2025 - 5 Nov 2025
Amount
Taking down existing street light fittings of any type/size/capacity fixed in any position i.e. on wall/ pole/ watch tower refixing the fitting in its original position after repairs complete all as specified and directed. Note:-Spares shall be measured and paid separately under item No 08 & 09.
S&F in replacement for New generation energy saving and environmental friendly long life LED street light capacity 45 watts colour temp 6500K lumen effeciency 100lm/W made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having bottom opening separate driver compartment with IP66 protection and impact resistance of IK08 with pre wired and necessary mounting arrangementsnd provision of 2.5 sqmm three core copper conductor cable multi stranded from fitting to security light pole and taking down old unserviceable Street Light Fitting form Electric Pole of any description complete all as specified and directed.
As per Item No.02 above but Street Light fitting of 60 Watt complete all as specified and directed.
As per Item No.02 above but Street Light fitting of 90 Watt complete all as specified and directed.
S&F in replacement of LED flood light fitting for High Mast light of 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection,with impact and corrosion resistant complete including taking down unserviceable flood light fittings complete all as specified and directed.
S&F in replacement of LED flood light fitting for High Mast light of 150 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection,with impact and corrosion resistant complete including taking down unserviceable flood light fittings complete all as specified and directed.
S&F in replacement of copper conductor cable 3 core ,2.5 Sqmm, 1100 volts multistranderd PVC insulated weather proof, sheathed heavy duty ISI marked drawing through 20mm dia PVC pipe/conduit from LED street light fitting to junction box with proper connection with thimbles as per site requirement complete all as specified and directed.
Supply and fixing in replacement of driver suitable for any type of street light 45W/60W/90W complete all as specified and directed.
Supply and fixing in replacement of Surge protection device suitable for any type of street light 45W/60W/90W complete all as specified and directed.
S&F polycarbonate thermoplastic outdoor junction box CPRI approved OEM make for steet lights of size 300mmx200mmx105mm with TPN bus bar and flap cover operate which should be shock proof, protection class-II, earthed , IP 66 weather proof , corrosion free , acid and chemical resistant , impact resistant, , ultra voilet resustant made of halogen & silicone free recyclable mtrl, internally embedded gasket with provision for cable entry through integrated flanges top and bottom. The gasket should be internally embedded made of polycarbonate incl with fixing arrangement (double clamps, nuts and Bolts etc.) complete with one double pole MCB 10 A all as specified and directed.
M&L for in replacement TPN MCB,4 pole 415 Volts, 50 Hz having rupturing capacity 10 KA of rating 40 to 100 Amps, C curve complete all as specified and directed.
M&L for in replacement MCB SPN, 240 Volts, 50 Hz, having rupturing capacity 10 KA of rating, 32 Amps complete all as specified and directed.
M&L MCB SP 5 to 32 Amps, 10 KA, C-curve complete all as specified and directed.
M&L painting of cement concrete poles with junction box,clamp and bracket any type of size externally above foundation with two coats of cement base paint for pole after scraping/cleaning well the existing surface with black and yellow or black white strips 30cm each up to 1.5 metre height from top of PCC foundation block and numbering of poles with synthetic enamel paint white in 80mm high letters over 150mm x 230mm yellow base complete all as specified and directed.
M&L painting of LT Steel tubular pole with junction box,clamp and bracket any type of size externally above foundation with two coat of aluminium paint after scraping/cleaning well the existing surface incl painting of bottom with black white or yellow color strip 30cm each upto 1.5 mtr high from top of PCC foundation block and numbring of pole with synthetic enamel paint white in 80mm high letter over 150mmx230mm yellow base complete all as specified and directed.
Supply and fixing in replacement Bracket made out of 40 mm dia galvanized steel tubing medium grade 1.5 m long including bending if required as directed ,02 Nos clamps made out of MS flat iron 40X6mm of suitable size fixed with bolts, nuts and washer including drilling holes and grouting with the same for fixing bolts complete all as specified and directed. Notes : Rates quoted by the contractor shall deemed to include for nut and bolts.
Supply and fixing insulation LT tape size normal width 20mm, length 25 mtr, thickness 0.125 mm complete all as specified and directed.
Supply, laying, jointing, testing and commissioning in replacement of cable XLPE insulated , armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, laid in trenches, fixed by means of MS saddles on or fixed on poles including connection with proper lugs for the following size including taking out old XLPE cable etc complete all as specified and directed. Note :- (i) Excavation and earth work shall be measured and paid separately.
10 Sqmm 2 Core.
10 Sqmm 4 Core.
16 Sqmm 4 Core.
25 Sqmm 3.5 Core.
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5 metre in depth for taking out of unserviceable under ground cable complete all as specified and directed.
Material and labour for sand cushioning with a layer of fine sand 8cm thick before laying of cable and 15cm thick after laying of cable in trenches complete all as specified and directed. Notes-:(i) Excavation and earth work to be measured and paid for separately. (ii)Thickness of 18cms after punning shall be considered for payment.
Supplying and laying bricks common burnt clay building bricks sub class 'B' including removing of old bricks complete all as specified and directed.
Returning, filling in, any type of soil and spreading in layers not exceeding 25 cm thick complete all as specified and directed.
Removal of surplus soil (any type of soil obtained from excavation) to a distance not exceeding 50 metre and depositing where directed complete all as specified and directed.
Supply and fix of Aluminium Lugs suitable for 10 to 35 Sqmm, 1100Volts including taking down old unserviceable lugs complete all as specified and directed.
M&L PCC (1:4:8), type D-2 using 40mm graded crushed stone aggregate as in foundation of electric poles, struts, PCC block including necessary form work and fair finish to exposed surfaces without using extra cement etc. complete all as specified and directed.
M&L PCC (1:3:6) type C-1 using 20mm graded crushed stone aggregate as in foundation filling upto ground level etc. complete all as specified and directed.
M&L PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregate as in coping of poles etc. with slightly rounded or chamfered angles including necessary form work and fair finishing the exposed surface without using extra cement complete all as specified and directed.
M&L for supply, erecting and fixing in position in replacement metre long steel tubular swaged pole type 410 SP-22 complete with cast iron base plate, final taper plug, bolts, nuts & screws conforming to IS-2713 (Part- I & III) of 1980 and painting the pole with two coats of aluminum paint over a coat of primer including black and white strips 30cm each upto 1.5 metre from top of PCC foundation block and numbering of poles in 80mm high white letter using synthetic enamel paint over base etc including taking down old existing pole and proper connection with existing condoctor complete all as specified and directed.
Supply and fixing in replacment GI pipe light grade 80 mm bore for cable protection fixed to poles/along wall/floor/under road/across the drain or nallah including taking out old GI pipe complete all as specified and directed.
M&L Earthing including earth work complete with galvanised steel earth plate electrode 60cm X 60 cm X 6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level with the top edge of electrode not less than 1.5 mtr below normal ground level connected to galvanised earth lead wire 4mm dia means of bolts, nuts,check nuts and washers of galvanised iron and GI lead protected with protection pipe of GI light grade 15mm dia upto 3mtr above ground level along poles fixed with two clamps of 25mm 3mm flat iron and connected to running earth wire at top of poles and watering pipe 20mm bore of GI medium grade all as shown in electrical plate No 3 of SSR Part-I 2009 connected to earthing test point all as specified and direct and testing on completion including PCC 1:3:6 ) C-I cover and frame excavation and earth work etc complete all as specified in elect plate No 3 of SSR Part -I 2009 Note :- PCC Chamber shall be constructed at least 1.50 mtr away from on the earth pit electrode and pipe for watering shall be provided in slanting manner.
Boring of holes under road, pavement, hard standing by trenchless technique and necessary T&P for passing of LT/HT cables complete all as specified and directed.
M&L for taking down unserviceable High Mast Light Fitting Set from any Height, repairing the same at site by opening cover after bringing down by using control gear box symmetrically fitted along with steel rope, replacing unservicable Parts such as driver, SPD and unserviceable/ burnt cable, etc. as required at site, after repairing fixing in the same Position including necessary greasing the gear box, checking control mechanisum with minor repairs as required complete all as specified and directed. Note : (a) Spare Parts such as driver, Surge protection device required will be measured and paid under appropriate Item(s) as ‘Supply only fix in item No 33 & 34. (b) Labour Element for replacement of unserviceable Parts will deem to be included in the Quoted Unit Rate.
Supply and fixing in replacement of driver suitable for any type of street light 120W/150W complete all as specified and directed.
Supply and fixing in replacement of Surge protection device suitable for any type of street light 120W/150W complete all as specified and directed.
Supply and fixing in replacement of Motor capacity 1 HP suitable for taking up and down High Mast lights complete all as specified and directed.
Supply and fixing PVC insulated,PVC sheathed multistranded copper conductor cable of size 4 core 10 Sqmm with necessary electrical connections from switch gear to high mast top connector block including taking down old unserviceable one complete all as specified and directed.
Supply only Stainless Steel rope twisted of size 10 mm dia with necessary connections proper binding on both sides from bottom drum mast top connecting hook including taking down old unserviceable one complete all as specified and directed.
S&F Surface/pole mounted astronomical time switch panel outdoor type of suitable size cubical type factory made, weather and vermin proof made out of polycarbonate thermoplastic outdoor junction box/CRCA sheet thick panel duly powder coacted heaving Astronomical time switch, Contactor suitable for street light time switch with 3 pole 32A/ 230V duly pre-wired with suitable size of copper conductor cable with proper size of copper lugs/thimbles,with cable gland and fixed on wall/pole with clamp, nut & bolts complete all as specified and directed. Make: L&T, Legrand, Schneider
S&F Integral LED Aviation light comprising of aluminium housing with ploycarbonate enclosure including taking down old unserviceable light from any height of OH tank complete all as specified and directed. Make Bajaj/Philips/Havells/Crompton.
S&F in replacement for LED post top lantern 40 watt light fitting made of cast aluminium spigot housing with decarative opal acrylic diffuser with IP 66 protection complete with all accessories fixed on GI pipe 50 mm dia including removal of old unserviceable one complete all as specified and directed.
S&F in replacement SITC of high-quality integrated LED sensor Street Light with a minimum system lumen of 6600 Lm and system wattage not exceeding 60W with a nominal efficiency 110 lumen/watt. CCT of 5700K with SDCM of < 5 and CRI >70. The housing should be of non-corrosive high-pressure die-cast aluminum with high efficiency LEDs as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 with PF > 0.95. Lifetime of 50K hours @L70. The Luminaire should have Powered by integral, Isolated LED electronic driver (SMPS based constant current supply) with lower THD, Output Open / Short Circuit protection, Phase to Phase protection (Operation at 440 V AC), Over Voltage protection, Surge Voltage protection upto 4 kV. Manufacturer shall have in house lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters complete all as specified and directed.
SUN MANN ENGINEERS (BID ID -3474425)
PARDEEP CONSTRUCTION COMPANY (BID ID -3481060)
Raman Electric Trading Co (BID ID -3484660)
Durga Electricals (BID ID -3485178)
R G ENTERPRISES (BID ID -3485742)
JASSI TRADERS (BID ID -3481074)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.16 MB
BOQ_823757.xls
BOQ • 0.42 MB
Tende54202526.pdf
Tender Documents • 0.67 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .