Executive Engineer SYL WS Division Ambala
Canal colony Model Town Ambala city
Cement concrete lining from 13.500 to km 13.830 on Kanwala Disty
2022_HRY_223190_1
31/05/2022
Open Tender
Civil Works
Item-rate/Agreement basic
40 days
Ambala
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
₹31,560
Yes
13 Jul 2022
24 May 2022
31 May 2022
24 May 2022
31 May 2022
24 May 2022
90 days
Amount
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering 1 : 2: 4 ( 1 Cement: 2 coarse sand (zone-Ill) : 4 graded stone aggregate 20 mm nominal size)
Lining with design mix concrete of grade M-15 with minimum cement content 240kg/cum, 75 mm thick in curve portion and side slope manually including rendering with 10 mm cement sand plaster (1:5) form work, dressing and preparation of sub-grade as per directions of Engineer-in-charge. 75mm thickness in bed (10 mm cement plaster 1:5)-33.00 (slurry)
Lining with design mix concrete of grade M-15 with minimum cement content 240kg/cum, 75 mm thick in curve portion and side slope manually including rendering with 10 mm cement sand plaster (1:5) form work, dressing and preparation of sub-grade as per directions of Engineer-in-charge. 75mm thickness in side slopes (10 mm cement plaster 1:5)-33 (slurry)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level+B50: Thermo-Mechanically Treated bars of grade Fe-500D or more Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement.
Excavating, supplying and filling of local earth (including royalty) by mechanical transport up to a lead of minimum 1 km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge.
Excavating conglomerate for drains and bed sleepers, under the lining by mechanical/ mannual means
Providing and Placing in position suitable PVC water stops conforming to IS:12200 for construction/ expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete : Serrated with central bulb (225 mm wide, 8-11 mm thick)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level Unit 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size
Centering and shuttering including strutting, propping etc. and removal of form for small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like
Providing and laying polythene sheet under CC M-25 in road and parking complete in all respect
Credit of old bricks
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .