Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.7 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | Not Admitted-Fee/PreQual/Technical/Finance | - | Not Admitted-Fee/PreQual/Technical/Finance EMD exemption certificate not valid | |
| 3 | Not Admitted-Fee/PreQual/Technical/Finance | - | Not Admitted-Fee/PreQual/Technical/Finance EMD exemption certificate not valid | |
| 4 | Not Admitted-Fee/PreQual/Technical/Finance 1507 SUB TREASURY NILAMBUR | KANNUR | KERALA | 670612 | - | Not Admitted-Fee/PreQual/Technical/Finance EMD exemption certificate not valid | |
| 5 | Not Admitted-Fee/PreQual/Technical/Finance | - | Not Admitted-Fee/PreQual/Technical/Finance EMD exemption certificate not valid |
Tender Value
₹11.8 L
EMD Value
₹29,500
Closing Date
6 Apr 2024, 3:00 pmClosed
Divisional Forest Officer
North Wayanad Forest Division, Mananthavady
RKVY 2023-24 - Erecting and commissioning of solar hanging fence arround Rassal kunnu colony in Thirunelly GP under Begur Range ( 1.40 km )
2024_FD_671307_1
D-1155/24
Open Tender
Electrical Works
Item Wise
90 days
Rassal kunnu colony
Please refer Tender documents.
5 documents required · 5 mandatory
₹2,785
Yes
₹29,500
Yes
27 May 2024
25 Mar 2024
8 Apr 2024
25 Mar 2024
6 Apr 2024
25 Mar 2024
Amount
APPENDIX A
od230583/2023_2024 : Energizer with following specifications 24 V Energizer (1) Must be from a reputed company (2) Must confirm to bis std 302-2-76 and national and international stander's safety (3 ) Switch to high and low power setting 4 solar panel option to re charge 12 V Battery 5.Should possesses the following out put characters 1 peak o/p voltage not more than 10 kv on soak load 2 o/o energy 3.5 / minim 3 pulse duration 1.01-3 .0 M sec 4 pulse interval 1.1 -1.4 sec 5 peak correct 7.0-8.0 a heigh 6 . 3 years warranty against manufacturing defects
od230584/2023_2024 : Solar Module with following specification(1) 150 wats 12 Volt retaining with minimum 10 years warranty against manufacturing deffects (2) Solar charge controller to regulate the charging of the battery
od230585/2023_2024 : Module stand with housing box to accomodate 2 no 100 AH battery
od230586/2023_2024 : 12 V tubular battery, 100 AH
od230587/2023_2024 : LIGHTNING DIVERTING KIT<br>Must be capable of diverting stray lightening. The diverter assembly must be adjustable for spark gaps.<br>Lightning diverter kit should be as close as possible to the Energizer<br>Adequate earthing to be provided.
od230588/2023_2024 : Earthing system must contain earth mixture capable of retaining moisture and 8 mm dia stainless steel rode - non resting quality of 4 feet long
od230589/2023_2024 : SUPER STRAIN INSULATOR
50.10.2 : Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
od230590/2023_2024 : Stainless steel wire 1.5 mm 304 grade non resting quality for main line
od230591/2023_2024 : Stainless steel 1.2 mm 304 grade non resting quality
od230592/2023_2024 : Stainless wire rope 1.5 mm dia and non resting quality for hanging line
od230593/2023_2024 : Bullets (connecters) - copper material or aluminium material or stainless steel material having an inner core size of 2.5 mm dia 2 cm length
od230594/2023_2024 : Bottom fixture with bush (adopter for 75 mm pipe in to 50 mm pipe acting as a insulator to energize the raiser pipe, the bush must be made of virgin PP or equivalent material and UV stabilized
od230595/2023_2024 : Supplying Digital Volt meter
od230596/2023_2024 : TOOL KIT<br>Should contain: Wire tightner handle, Twisting tool, Pliers, Double ended spanner for clamp tightning
od230597/2023_2024 : Warning signs poly-ethylene plastic with statutory colors and signs
od230598/2023_2024 : LEAD OUT CABLE<br>Must be double insulated with standing 15 kv voltagages. Inner core wiremust be hot dip galvanized. For under gate and base unit connection.
od230599/2023_2024 : Erection charges
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
2.32 : Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.
4.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Bidder Name
TRANS POWER ENGINEERS
tech_eval.pdf
fin_eval.pdf
aoc.PDF
finance_1044644.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .