No. 2023-24 L.C Unit
Excavation for foundation upto 1.5 m depth
including sorting out and stacking of useful
materials and disposing off the excavated stuff upto 50 359.37 148.19 1.48 149.67 Cmt
Meter lead.(B)
Dense or hard soil
CH-4 ITEM CODE 04001B PG-46
Excavation for foundation for depth from 1.5 m to
m including sorting out and stacking of
useful materials and disposing off the 297.70 160.77 1.61 162.38 Cmt
excavated stuff upto 50 Meter lead.(B)
Dense or hard soil
CH-4 ITEM CODE 04002B PG-46
Providing & laying Cement Concrete 1:2:4 (1 Cement :
Coarse Sand : 4 graded stone aggregate 20 mm
nominal size) & curing complete excluding cost of form 34.35 3535.40 35.35 3570.75 Cmt
work Below Tie beam & Plinth protection.
CH-5 ITEM CODE 05010AA PG-48
Providing and laying controlled cement concrete M.150
for curing complete including cost of formwork and
excluding cost of reinforcement for reinforced
4 concrete work in (A) Foundations, footings,Base
of columns and Mass concrete (Cement Level
Brick work using common burnt clay building bricks
having crushing strength not less than 35 kg./Sq.Cm. in
foundationand plinth in Cement Mortar 1:6. (1‐ Cement : 76.83 4725.60 47.26 4772.86 Cmt
6 ‐finesand)(C) Fly Ash Bricks
CH-6 ITEM CODE 6002CA PG-58
Filling with the available excavated earth (excluding
rock) in trenches, plinth, sides of foundation etc. in
6 layers not exceeding 20cm in depth consolidating each
deposited layer by ramming and watering.
CH-4 ITEM CODE 04006 PG-47
in layers of 20 cm. thickness inculding watering, 391.37 286.20 2.86 289.06 Cmt
ramming and consolidation etc. complete.
CH-4 ITEM CODE 04008A PG-47
Providing and laying controlled cement concrete M.250
for curing complete including cost of formwork and
excluding cost of reinforcement for reinforced
8 concrete work in (a) Foundations, footings Bases of
columns and the like and Mass conrete work in footing.
(Cement Level 380 Kg)
Providing & laying Cement Concrete 1:4:8 (1 Cement :4
Coarse sand :8 hand brocken stone aggregates of
9 40mm nominal size) in plinth and curing complete
excluding cost of formwork.
CH-5 ITEM CODE 05004A PG-49
Providing and laying controlled cement concrete M.250
for curing complete including cost of formwork and
excluding cost of reinforcement for reinforced 48.50 6071.00 60.71 6131.71 Cmt
concrete work in Plinth Beams. (Cement Level
ITEM SOR SOR+1% Per
DESCRIPTION OF ITEM QTY 1% L.C Estimated Amount
No. 2023-24 L.C Unit
Brick work using common burnt clay building bricks
having crushing strength not less than 35Kg./Sq.Cm. for
superstructure in cement mortar 1:6(1 cement :6 fine
11 sand) including curing etc. complete. (C) Fly Ash Bricks
For all heights and all floor
CH-6 ITEM CODE 6002CA +6006C PG-58
Half brick in common brunt clay building bricks having
crushing strength not less than 35 Kg/sq.cm in cement
mortar 1:4 (1 cement : 4 coarse sand) (C) Fly Ash 38.75 645.22 6.45 651.67 Smt
Bricks in super structure including curing etc.
complete.For all floors
CH-6 ITEM CODE 6008A2A +6010B PG-59/60
Providing and laying controlled cement concrete M.200
for curing complete including cost of formwork and
excluding cost of reinforcement for reinforced 39.60 6027.00 60.27 6087.27 Cmt
concrete work in Beams for all floors level. (Cement
Level 360 Kg)
Providing and laying controlled cement concrete M.250
for curing complete including cost of formwork and
excluding cost of reinforcement for reinforced 26.65 7156.00 71.56 7227.56 Cmt
concrete work in Column Up to Plinth & all floors..
(Cement Level 380 Kg)
Providing and laying controlled cement concrete M.200
for curing complete including cost of formwork and
excluding cost of reinforcement for reinforced 37.82 7093.00 70.93 7163.93 Cmt
concrete work in Column for all floors level. (Cement
Level 360 Kg)
Providing and laying controlled cement concrete M.200
for curing complete including cost of formwork and
excluding cost of reinforcement for reinforced 62.85 6759.00 67.59 6826.59 Cmt
concrete work in Slab for all floors level. (Cement
Level 360 Kg)
Providing and laying controlled cement concrete M.200
for curing complete including cost of formwork and
excluding cost of reinforcement for reinforced
concrete work in sloping slabs & Staircase having 13.39 5520.00 55.20 5575.20 Cmt
thickness more than 10 cm and upto 20 cm
thickness.For all floors. (Cement Level 360 Kg)
Providing and laying controlled cement concrete M.200
for curing complete including cost of formwork and
excluding cost of reinforcement for reinforced
concrete work in Chhajja for all floors level including 3.79 6551.00 65.51 6616.51 Cmt
finishing with cement mortar 1:3 ( 1 cement :3 Sand )
and curing etc complete. (Cement Level 360 Kg)
Providing I.S.I. T.M.T Bars Fe.500D steel reinfocement
(ISI mark) Confirmed to IS-1786 for R.C.C.work
19 including Cutting, bending, binding and placing in
position etc. complete.For all floors
CH-5 ITEM CODE 05014C PG-50
ITEM SOR SOR+1% Per
DESCRIPTION OF ITEM QTY 1% L.C Estimated Amount
No. 2023-24 L.C Unit
Providing 10mm thick cement plaster in single coat on
on brick/concrete walls & Ceilling & Soffit of stair interior
plastering in cement mortar 1:4(1 cement 4 sand) 588.93 172.47 1.72 174.19 Smt
watering, curing etc. complete.For all floors
CH-17 ITEM CODE 17001B+17004A PG-89
Providing 15mm thick cement plaster in single coat on
rough or fair side of single or half brick wall for interior
21 plastering in cement mortar 1:4(1 cement 4 sand)
watering, curing etc. complete.For all floors
CH-17 ITEM CODE 17002A+17004A PG-89
20mm thick sand faced cement plaster on walls above
ground level consisting of 12mm thick backing coat of
cement mortar 1:3(1 cement 3 sand) and 8mm thick
22 finishing coat of cement mortar 1:1(1 cement 1 sand)
watering, curing etc.complete for any Height.
CH-17 ITEM CODE 17009 PG-89
Provinding & applying three coat of 100% acrylic
base matt finishing exterior paint of approved
manufacture of required shade on external surface to
23 give an even shade after throughly brushing the surface
free from morter dropping & other foreign matter
Providing & laying 24"x24" vitrified 8mm thick tiles
flooring over 20mm (average) base of cement mortar
1:6(1cement:6course sand) on new surface or fixing on
exiting flooring by adhesivematerial including
dismentalling of existing flooring and jointed with colour
24 cement slurry including finish with flush pointing and
cleaning the surface etc. complete for antiskid.(As Per
List of Approved Materials) for Light/Dark shade as per
the given pattern.
(Item No- 14021A , Pg No- 85)
Providing and laying 25 mm th. Polish Kota stone
slab flooring over 20mm. (average) base of cement
mortar 1:6 (1 cement :6 coarse sand) of L.M. 1:1.5 and 126.16 967.05 9.67 976.72 Smt
laid and jointed with grey cement slurry including rubbing
and polishing complet.
(Item No- 14.43 , Pg.No. 84)
Providing & laying cement concrete flooring over
mm (average) thick base of cement flooring 1:2:4
(1cement:2 coarse sand:4 graded stone aggregates
26 20mm normal size) laid in one layer finished with a
floating coat of neat cement curing etc. complete.
(Item No-14.71 , Pg.No. 85)
Providing cement vata (10cmx10cm size)quarter
round in cement mortar 1:1 including neat cement 88.95 23.45 0.23 23.68 Rmt
finishing,watering etc. complete )
Providing & Fixing in position M.S.Angle
40mmx40mmx6mm Angle frame for door and
35mmx35mmx5mm angle frame for shutters,18 gauge
28 iron sheet of shutters with 4 nos.of hold fasts for door as 1475.28 101.60 1.02 102.62 Smt
per the approved drawong & design including applying a
priming coat.( Pg No-68) Sr.No. 10025AA
ITEM SOR SOR+1% Per
DESCRIPTION OF ITEM QTY 1% L.C Estimated Amount
No. 2023-24 L.C Unit
Providing & Fixing in position M.S.Angle
35mmx35mmx6mm frame for windows & ventilation
25mmx25mmx5mm angle frame for shutters, 18 gauge
29 iron sheet of shutters with 4nos. Of hold fasts for 1340.04 101.60 1.02 102.62 Smt
windows & Ventilation as per the approved drawing &
design including applying a priming coat..( Pg No-68)
Providing & fixing M.S. Railing & M.S grill as per approved
30 drawing & design including one coat of red lead paint etc. 2478.85 101.60 1.02 102.62 Kg
complete.( Pg No-68 Sr.No100 25AA
Painting two coats (Excluding Priming coat) on new
steel and other metal, surfaces with enamel paint,
brushing,interior to give an even shade including 253.20 86.94 0.87 87.81 Smt
cleaning the surface of all dirt, dust and other foreign
matter etc,complete
(Item No-19.7 , Pg.No. 93)
Providing & fixing G.I rain water Spout of 65mm dia and
60cm length. RA
Distempering with dry distemper of approved brand
and manufacture (Three Coats) and of required shade
on wall surface to give an even shade, over and
33 including a priming coat of whiting after throughly
brooming the surface free from mortar dropping and
other foreign matter.
(Item No- 18.38, Pg.No. + 18.40 Pg.No. 91 )
Providing and fixing Chicken mesh jali (22 gauge)30cm
wide at the junction of 2 different surfaces of different
material component at the time of plastering to prevent
cracking in plaster surface as and where directed at all
floors with all leads and lifts etc.complete.RA
Point wiring for Light / Bell with 2-1.5 sq.mm & earth
wire of 1.5 sq.mm (Green) both are of ISI marked 1.1 KV
grade FRLS PVC insulated multi strand copper wires up
to 10 mtr length , in below type of pipe erected with 6A
Modular type switch / bell push & accessories and earth
continuity of following type, erected on PVC /
Metallic/Wooden box, single mounting base frame
covered with textured/metallic/white front plate modules
erected on / in wall / ceiling as per pipe erected, with
necessary Lamp holder/ceiling rose / H.D.Connector as
directed. (a) with medium class Rigid PVC pipe and
accessories erected flushed on wall/ceiling complete
Cat. III ELE R&B 22-23 1-2-1
Point wiring for FAN with 2-1.5 sq.mm & earth wire of
1.5 sq.mm (Green) both are of .ISI marked 1.1 KV Grade
FRLS PVC insulated multi strand copper wires up to
mtr length, in below type of pipe erected with 6A
Modular type switch and hum free EME four or more
step type electronic fan regulator with separately
mounted and accessories with earth continuity of
36 following type erected on PVC / Metallic/Wooden box, 24.00 699.00 6.99 705.99 Pt.
single mounting base frame covered with
textured/metallic/white front plate modules erected on /
in wall / ceiling as per pipe erected. with necessary
ceiling rose / H.D.Connector as directed. (a) with
medium class Rigid PVC pipe and accessories erected
flushed on wall/ceiling complete Cat. III ELE R&B 22-23
ITEM SOR SOR+1% Per
DESCRIPTION OF ITEM QTY 1% L.C Estimated Amount
No. 2023-24 L.C Unit
Point wiring for on board Looped Plug with 6A Modular
type switch & 5 pin socket erected on PVC /
Metallic/Wooden box, single mounting base frame
37 covered with textured / metallic/white front plate 33.00 281.00 2.81 283.81 Pt.
modules erected on / in wall / ceiling with following type
accessories Cat. III ELE R&B 22-23 1-2-4
Point wiring for Individual Plug with & earth wire of 1.5 sq.mm
(Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated
multi strand copper wires up to 10 mtr length, in below type of pipe
erected complete with Modular type switch & 5 pin Plug erected on
PVC / Metallic/Wooden box covered with appropriate front plate
modules erected on / in wall / ceiling as per pipe erected with
following type of accessories.[II] For 16A Plug and 16 amp switch
with 2-2.5 sq.mm Cu. Wire from mcb db board.(e) in existing pipe
erected flushed on wall/ceiling complete,Cat. III ELE R&B 22-23 1-2-
Providing following type of Modular Type Accessories
mounted with PVC / metallic/Wooden box, single
mounting base frame covered with textured /
39 metallic/white front plate , modules erected with 66.00 28.00 0.28 28.28 NO
necessary connections as per site situation directed by
Engineer In charge. (7) Blank Plate Single Cat.III ELE
Providing and erecting ISI mark Medium class RIGID
PVC PIPES of following size complete to be erected
on/in wall or ceiling erected with necessary PVC fittings
40 & Junction boxes fixed with adhesive solution & Clamps 260.30 26.00 0.26 26.26 Rmt
with following dia of pipes, in approved manner as
directed (a)20 mm ELE R&B 22-23 1-3-2
Providing and erecting Mains with 1.1 KV grade FRLS
PVC insulated ISI marked stranded Copper conductor
wire in following type of pipe to be erected concealed in
/flushed on wall/ceiling, with 1.5 sq. mm copper
conductor FRLS PVC insulated stranded wire of green
colour for earth continuity of following size (A) with
medium class Rigid PVC pipe and accessories (a) 2 wire
Providing and erecting Mains with 1.1 KV grade FRLS
PVC insulated ISI marked stranded Copper conductor
wire in following type of pipe to be erected concealed in
/flushed on wall/ceiling, with 1.5 sq. mm copper
42 conductor FRLS PVC insulated stranded wire of green 91.35 51.00 0.51 51.51 Rmt
colour for earth continuity of following size (A) with
medium class Rigid PVC pipe and accessories (b) 2 wire
2.5 sq. mm ELE R&B 22-23 1-4-1
providing and erecting Mains with 1.1 KV grade FRLS
PVC insulated ISI marked stranded Copper conductor
wire in following type of pipe to be erected in / on wall /
ceiling with 2.5 sq. mm copper conductor FRLS PVC
43 insulated stranded wire of green colour for earth 46.80 123.00 1.23 124.23 Rmt
continuity of following size (A) with medium class Rigid
PVC pipe and accessories (a) 2 wire 4 sq. mmELE R&B
ITEM SOR SOR+1% Per
DESCRIPTION OF ITEM QTY 1% L.C Estimated Amount
No. 2023-24 L.C Unit
Supplying and erecting LED indoor fittings with LEDs of wattage
Watt to 0.5 Watt assembled on single MCPCB, with housing used as
a heat sink shall be made of co-extruded polycarbonate channel with
diffuser part in needed opal finish with company mark/name 160V to
270V, Power Factor more than 0.9, THD < 15%,
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt ,LED
44 LED driver efficiency > 85 % 30.00 345.00 3.45 348.45 NO
( fitting required LM-79 & LM-80 Certificates)(NOTE: Below
description have shown ranges of Wattage capacity of LED
between the ranges shown.),(A) Tube Light with integral driver,(ii)
18-20 Watts, Surge - 2KV,IP-20, conventional 4 feet,Cat-lll ELE
Providing & erecting Approved make Power Saving
Watt Ceiling Fan with double ball bearing ISI mark
with Condenser 230 volt A.C. 50 Hz 1200 mm
sweep complete having 3blades with aluminium
blades with , canopy & 30 cm. down rod erected
with 3 core flexible wire with earthing.(Make shall
be approved by Engineer in charge) R&B 22-23 5-1-
Supplying and erecting 19 / 20 mm. nominal bore
Medium Class M.S. Pipe down rod erected duly
46 painted for fan complete with proper insulation 24.00 110.00 1.10 111.10 Rmt
without leakage and earthing ELE R&B 22-23 5.2.2
Supplying & erecting Fan Hook of 10 mm M.S. Round
47 bar grouted in RCC slab with Making the site as 24.00 50.00 0.50 50.50 NO
original.ELE R&B 22-23 5-2-2
Providing and erecting Sheet Steel powder coated MCB distribution
board - flush / surface mounted fitted with busbar, neutral link, earth
bar and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 &
without MCB to house appropriate nos. of MCBs.(The DBs should
48 be used of same company of MCB to be used) suitable for(B) three 6.00 4525.00 45.25 4570.25 NO
phase incoming and single phase horizontal type outgoing Per phase
isolation type (PPI),(b) sheet steel double door,(iv)12 way R&B 22-
providing and erecting Miniature circuit breaker single
pole 6A to 25A suitable to operate on 240 V A.C. system
49 and having breaking capacity 10 KA to be erected in 18.00 117.31 1.17 118.48 NO
existing box. confirming to IS 8828/1996 with ISI Mark
Cat.III R&B 22-23 3-10-1(B)
providing and erecting Approved make ELCBs / RCCBs
conforming to IS: 12640 and having sensitivity of 30 mA
and Short Circuit withstand capacity of 10 KA and
suitable for operation on single phase 240 V,50Hz.
50 having characteristic of quick action & tripping with all 6.00 2323.00 23.23 2346.23 NO
advance feature & do not incorporate any electronic
component. for following Max. rating erected as directed
(i) 25 Amps.DP Cat. III R&B 22-23
Providing & erecting 240 V MCB double pole switch for
lighting Load (B Curve) having 10 KA breaking capacity
51 & confirms to IS : 8828 in existing box having following 6.00 325.00 3.25 328.25 NO
capacity (A) 6 to 32 Amp. Cat.III ELE R&B 22-23 3-10-3
Sheets steel powder coated enclosure suitable for
52 incorporating One/Two nos. MCB.ELE R&B 22-23 3-11- 6.00 205.00 2.05 207.05 NO
ITEM SOR SOR+1% Per
DESCRIPTION OF ITEM QTY 1% L.C Estimated Amount
No. 2023-24 L.C Unit
Providing & erecting Medium Voltage Danger Notice
Board sticker as per language suggested by engineer
incharge of standard size as per IS-2551 ELE R&B 22-
Providing & erecting 240 V MCB double pole switch for motor &
inductive load (C Curve) having 10 KA breaking capacity &
54 confirms to IS : 8828 in existing box having following capacity ,(A) 6 6.00 350.00 3.50 353.50 NO
to 32 Amp. Cat.III ELE R&B 22-23 3-10-2
Erection & connection charges for 16A / 32 A DP as
55 following (b) on polished wooden block.ELE R&B 22-23 6.00 20.00 0.20 20.20 NO
Supplying & erecting earth pit of minimum bore
dia.150mm size approved make Earthing Electrode
consisting Pipe-in-Pipe Technology as per IS 3043-1987
made of corrosion free hot dipped G.I.Pipes having
Outer pipe dia of 50mm having 80-200 Micron
galvanising, Inner pipe dia of 25 mm having 200-250
Micron galvanising, connection terminal dia of 12mm
with constant ohmic value surrounded by highly
conductive compound with high charge dissipation
suitable for following type of applications with chamber
and heavy duty cover.(approved make OEM has to
submit test certificate) & having back filling compound of
(B) Inner chemical (CCM Compound)- Resistivity:-
/ meter testing as per IEC 62561-2017, Voltage drop:-
< 1 volt at no load & dry form, Sulphar content:- <2%(C)
Back fill Compound :- Earthing compound should be
capable to retain moisture for long time Necessary test
report must be submitted. (a) For Electrical Installation
up to 440V in normal soil
Length of pipe - 1 Mtr
Back filling compound - 1 Nos Bag of 15 Kg.
Providind and erecting HOT deep Galvanised iron strip
57 wire 8 TO 16 SWG. 5.00 90.90 0.91 91.81 Kg
Total Rs.
SAY RS.
I / WE am / are willing to carry out the work at ________ % above / below (percentage should be
written in figures and words) of estimated rates mentioned above. Amount of my / our tender works
Estimated amount put to tender Rs. ________________
Deduct / Add: _____ % below / above Rs. ________________
Net Amount Rs. ________________
in words _____________________________________________________________
(Please strike out which ever is not applicable)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Day-Month-Year (14).pdf
Drawing.pdf
SPECIFICATION.pdf
SS.TASP.ACR.CHHOTA.01 (BOQ).pdf
SS.TASP.ACR.CHHOTA.01.pdf
Download all tender documents and submit your bid