Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹80.4 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | Rejected-Technical | - | Rejected-Technical BID IS NON RESPONSIVE | |
| 3 | Rejected-Technical | - | Rejected-Technical BID IS NON RESPONSIVE |
| Sl No | Description | Qty | Unit | VAGMINE ENTERPRISES L1 |
|---|---|---|---|---|
| 1.00 | Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in allrespects, as required
(a) Horizontal type, multistage, centrifugal, split casingpump of cast iron body & bronze impeller with stainlesssteel shaft, mechanical seal conforming to IS 1520.
(b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operationon 415 volts, 3 phase 50 Hz, AC supply with IP 55protection for enclosure, horizontal foot mounted typewith Class-'F' insulation, conforming to IS-325.(c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered
1620LPM at 70 mtrs Head | 1 | Each | 3,33,000 ₹3,33,000 Lowest |
| 2.00 | Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable forautomatic operation and consisting of following,complete in all respects, as required : (Diesel Driven Pump)
Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft,mechanical seal conforming to IS 1520.
Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thickaluminium sheet cladding, residential silencer,instruments and protection as per standard specification, stop solenoid for auto stop in the event offault with audio indications, painted with post office redcolour etc. as required.
M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. suitable cement concrete foundation duly plasteredand with anti vibration pads.
1620LPM at 70 mtrs Head | 1 | Each | 5,95,000 ₹5,95,000 Lowest |
| 3.00 | Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for
automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520.
suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.
Suitable cement concrete foundation duly plastered and with anti vibration pads.
180 LPM at 56 mts head | 1 | Each | 81,500 ₹81,500 Lowest |
| 4.00 | Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520
b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.
(d) Suitable cement concrete foundation duly plastered and with anti vibration pads.
900 LPM at 35 mtrs Head | 1 | Each | 1,02,000 ₹1,02,000 Lowest |
| 5.00Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect,suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required : INCOMING 400A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Digital Ammeter (0-250 A) with selector swtich & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 300A OUTGOING ( Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps) | ||||
| 6.00Main Fire Pump 200 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 HP pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. | ||||
| 7.00Jockey Pump 100 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. | ||||
| 8.00DIESEL ENGINE CONTROL Control for diesel engine comprising - Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0- 20 A DC Ammeter | ||||
| 9.00 | All standard relays and accessories for automatic operation of diesel engine System Controller Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification | 1 | set | 2,90,000 ₹2,90,000 Lowest |
| 10.00 | Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required.
150mm dai | 150 | RM | 2,385 ₹3,57,750 Lowest |
Tender Value
₹80.5 L
EMD Value
₹1.6 L
Closing Date
6 Sept 2025, 3:00 pmClosed
DGM HQ BRIDCUL
BRIDCUL Opp Govt ITI Niranjanpur Saharanpur Road Dehradun
Proposed Fire Fighting work of Admin and Allied Building at CIPET Doiwala District Dehradun 5th Call
2025_BRID3_86493_1
1838/BRIDCUL/844/25 Dated 20.08.2025
Open Tender
Electrical Works
Item Rate
365 days
Doiwala Dehradun
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,900
MD - BRIDCUL
₹1.6 L
BRIDCUL Dehradun
12 Nov 2025
22 Aug 2025
6 Sept 2025
22 Aug 2025
6 Sept 2025
30 Aug 2025
29 Aug 2025
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .