Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.5 LAccepted-AOC | L1 | Accepted-AOC Over all rates are reasonable and lowest. | |
| 2 | L2₹14.7 L+₹79,990 (5.74%)Rejected-Finance VILL ATA KAYASTHAN P O VILVA BHOJIPURA BAREILLY 243202 UP | BAREILLY | BAREILLY | UP | 243202 | L2 | Rejected-Finance Over all rates are higher than L-1. | |
| 3 | L3₹14.7 L+₹80,868 (5.80%)Rejected-Finance WARD NO 11 THIRIYA NIZAWAT KHAN BAREILLY | BAREILLY | BAREILLY | L3 | Rejected-Finance Over all rates are higher than L-1. | |
| 4 | L4₹16.9 L+₹3.0 L (21.3%)Rejected-Finance THIRIYA NIZAWAT KHAN JAMAMASZID WARD NO 07 BAREILLY 2430021 UP | BAREILLY | UTTAR PRADESH | 243002 | L4 | Rejected-Finance Over all rates are higher than L-1. | |
| 5 | L5₹18.2 L+₹4.2 L (30.2%)Rejected-Finance C O MODERN FURNITURE B I BAZAR BAREILLY CANTT BAREILLY 243001 UP | BAREILLY | BAREILLY | UP | 243001 | L5 | Rejected-Finance Over all rates are higher than L-1. |
Tender Value
₹32 L
EMD Value
₹64,000
Closing Date
13 May 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
BAREILLY
GE WEST BAREILLY
PETTY REPAIRS TO INTERNAL ELECTRIC SYSTEM AT NEW MH AND CONNECTED SINGLE ACCN OF MH BAREILLY CANTT UNDER GE (WEST) BAREILLY
2024_MES_650878_1
8175/C/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE WEST BAREILLY
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE WEST BAREILLY
₹64,000
Yes
27 Jun 2024
23 Apr 2024
15 May 2024
23 Apr 2024
13 May 2024
8 May 2024
Amount
Taking down carefully existing Aluminum/Copper point wiring (light/ Fan / Socket/Power Point) complete fittings etc. making good to disturbed surface of wall/Floor etc to match the existing surface/ finishes complete all as specified and directed.
M&L for concealed point wiring with 1.5 Sqmm (Nominal area) PVC insulated,unsheathed, multi stranded Copper conductor cable drawn in and including PVC rigid PVC conduit 25mm or higher size with all its fittngs and accessories for one 3 pin/6 pin 15 Amps socket out let point independent alongwith PVC insulated cable with multistranded copper conductor 1.5 Sqmm (nominal area) continuous earth wire, and connected to earth dolly including fixing of 1.20 mm sunk pressed steel terminal box/ MS modular box suitably flushed to wall with 3mm thick Hylum sheet cover/ white colour modular plate with cover for housing switch, socket regulator etc fixed with screws & cup washers incl. making good complete all as specified and directed.
(a) All as per item no.2 here in before but for One light/fan point controlled by one switch 5/6 Amp one way complete all as specified and directed.
(b) All as per item no.2 here in before but for socket outlet 3/5 pin 5 amp. on the same board complete all as specified and directed.
(c ) All as per item No 02 here-in-before but for 5 Amps 3/5 Pin point on independent board complete all as specified and directed.
(d) All as per per item No 02 here-in-before but for one light point controlled by two Nos of 2 way switches complete all as specified and directed.
All as per item No. 2 above but wiring with 2.5 Sqmm (Nominal area) PVC insulated,unsheathed, multi stranded Copper conductor cable drawn in and including PVC rigid PVC conduit 25mm or higher size with all its fittngs and accessories for one 3 pin/6 pin 15 Amps socket out let point independent alongwith PVC insulated cable with multistranded copper conductor 2.5 Sqmm (nominal area) continuous earth wire, and connected to earth dolly including fixing of 1.20 mm sunk pressed steel terminal box/ MS modular boxe suitably flushed to wall with 3mm thick Hylum sheet cover/ white colour modular plate for housing switch, socket regulator etc fixed with screws & cup washers incl. making good complete all as specified and directed.
Supply and Fixing P/switch flush type 5/6 Amp SP one way complete all as specified and directed.
Supply and Fixing in repairs P/switch flush type 5/6 Amp SP one way complete all as specified and directed.
Supply and Fixing P/switch flush type 5/6 Amp SP two way complete all as specified and directed.
Supply and Fixing P/switch flush type 15/16 Amp SP one way complete all as specified and directed.
Supply and Fixing in repairs P/switch flush type 15/16 Amp SP one way complete all as specified and directed.
Supply and Fixing ceiling rose 2/3 terminals complete all as specified and directed.
Supply and Fixing in repairs ceiling rose 2/3 terminals complete all as specified and directed.
Supply and Fixing lamp holder PVC Angular/ pendent/ bakelite.complete all as specified and directed.
Supply and Fixing in repairs lamp holder PVC Angular/ pendent/ bakelite.complete all as specified and directed.
Supply and Fixing in repairs Switch socket combination 5 amp flush type complete all as specified and directed.
Supply and Fixing in repairs Switch socket combination 2 in one 5 and 15 Amp flush type complete all as specified and directed.
Supply and Fixing in repairs buzzer, capton ding dong, AC, 230V, sigle pole complete all as specified and directed.
Supply and fixing bell push switch flush type complete all as specified and directed.
Supply and Fixing socket outlet ,3/5 pin 5 amp flush type complete all as specified and directed.
Supply and Fixing in repairs socket outlet ,3/5 pin 5 amp flush type complete all as specified and directed.
Supply and Fixing socket outlet 2 in one, 3/5 pin 5 and 15 Amp flush type complete all as specified and directed.
Supply and Fixing in repairs socket outlet 2 in one, 3/5 pin 5 and 15 Amp flush type complete all as specified and directed.
Supply and Fixing in repairs Modular switches 1 way, 6 A, 1 module complete all as specified and directed.
Supply and Fixing in repairs Modular switches 1 way, 16 A, 1 module complete all as specified and directed.
Supply and Fixing in repairs Modular sockets 6 A,-2/3 pin combined 2 module complete all as specified and directed.
Supply and Fixing in repairs Modular sockets 6 A/ 16 A,-2/3 pin combined 2 module complete all as specified and directed.
Supply and Fixing in repairs Modular fan regulators step type, 120 W, 2 module complete all as specified and directed.
Supply and Fixing in repairs fan regulator resistance/electronic step piano type single phase 230 volt. complete all as specified and directed.
Supply and Fixing in repairs Hylem sheet 3mm thick of size 9'' X 11'' including cutting of sheet for fixing switch / socket. complete all as specified and directed.
Supply and Fixing in repairs Hylem sheet 3mm thick of size 8'' x 5'' including cutting of sheet for fixing switch / socket. complete all as specified and directed.
Supply and Fixing in repairs Hylem sheet 3mm thick of size 5'' x 5'' including cutting of sheet for fixing switch / socket. complete all as specified and directed.
Supply and Fixing in repairs MCB SPN 20 to 32 Amps 240 volts.10kA complete all as specified and directed.
Supply and Fixing in repairs MCB SP 6 to 32 Amps 240 volts, 10 kA. complete all as specified and directed.
Supply and Fixing in repairs MCB TPN 63 Amps,415V,10kA complete all as specified and directed.
S &F in repair MCCB 16 kA,125Amp thermal magnetic and electronic earth leakage module complete all as specified and directed.
Taking down unserviceable existing sub main wiring with aluminium conductor stranded cable upto 6 Sqmm single core including earth wire from existing conduit or wooden battens including taking out unserviceable wooden gutties etc, matching with the existing surfaces complete all as specified and as directed. .
M & L Sub main wiring concealed type with two single core cable PVC insulated cable with 4.0 Sqmm (Nominal area) multi stranded copper conductor cable 1100 volts gde incl earth continuity conductor using PVC insulated cable of copper conductor of size 4.0 Sqmm connected to common earth dolly and drawing into rigid PVC conduit with lock pattern incl. making good the disturbed surface complete all as specified and directed. (Note : PVC conduit and its accessories including 2 runs of cable 4 sq mm & 1 run of earth continuity conductor cable 4 sq mm unsheathed shall be measured and paid as single unit).
M & L Sub main wiring concealed type with two single core cable PVC insulated cable with 6.0 Sqmm (Nominal area) multi stranded copper conductor FRLS cable 1100 volts gde incl earth continuity conductor using PVC insulated cable of stranded copper conductor of size 6.0 Sqmm connected to common earth dolly and drawing into rigid PVC conduits of 25 mm dia medium grade size incl. making good the disturbed surfaces complete all as specified and directed. (Note : PVC conduit and its accessories including 2 runs of cable 6 sq mm & 1 run of earth continuity conductor cable 6 sq mm unsheathed shall be measured and paid as single unit).
S&F in replacement sheet metal enclosure DB's 415 Volts, IP-42, vertical suitable for mounting MCCB's, TPN, 12 way with 200 Amps rated copper bus bar complete all as directed by Engineer-in-charge.
Supply and Fixing in repairs double door MCB distribution boards sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail single phase and neutral confirms to IS : 13032-1991 of 4 ways complete all as specified and directed.
Supply and Fixing in repairs double door MCB distribution boards sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail single phase and neutral confirms to IS : 13032-1991 of 8 ways complete all as specified and directed.
Supply and Fixing in repairs double door MCB distribution boards sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail single phase and neutral confirms to IS : 13032-1991 of 12 ways complete all as specified and directed.
Supply and Fixing in repairs 4 Pin CFL lamp 36Watt complete all as specified and directed.
S & F in repairs 2 Pin CFL 18 W lamp/LED bulb thread type complete all as specified and directed.
S&F in replacement LED fitting with PVC extruded battern 20 watt 4 feet White colour including dismentiling and taking down any type of FTL/LED complete all as specified and directed.
S&F in replacement LED fitting with PVC extruded battern 10 watt 2 feet White colour including dismentiling and taking down any type of FTL/LED complete all as specified and directed.
S&F in repairs building security light led type 25 W complete all as specified and directed.
S&F 2'x 2' LED recess/ surface mounted fitting 36 Watt, 230V, with integrated electronic driver high transcluent frosted diffuser, connector block, etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
S&F 2'x 2' inverter LED 2x2 panel is CRCA powder coated and IP 20 with battery back up and functioning as per product TDS recess/ surface mounted fitting 36 Watt, 230V, with high transcluent frosted diffuser, connector block, etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
S&F in repairs 4mm thick E-board tiles for insulation and acoustic purpose including aluminium snap grid with 25x25x1.5 mm thick tee section and 38x52x2 mm thick angle with hanging/suppoting arrangements as in false ceiling at bottom at spacing 60cm centre to centre including necessary GI cleats and 4mm dia GI wire as suspender fixed to ceiling not exceeding 1.20 mtr centre both ways with dash fasteners cmplete and making good disturbed surfaces including taking down old ceiling any type complete all as specified and directed.
S&F in replacement of PVC non metallic casing caping of 25 mm size with accessories including dismentaling/takingdown of old unserviceable/broken PVC conduit/cashing caping fixed on surface/concealed inclduing making good the disturbed surface complete all as specified and directed
Supply and Fixing in repairs flexible wire 23/0.0076 PVC insulated copper conductor twin core complete all as specified and directed.
Taking down ceiling fans 1200/1400 mm sweep & removing/cleaning of dust properly, oiling and greasing of bearing including re-fixing and connecting up with all requisite accessories complete all as specified and directed.
M & L Re-winding of burnt fan motor of 1200/1400 mm sweep including internally and externally cleaning of fans and removing the burnt coil and re-winding of fans by super enameled copper wire of appropriate size, make (ATLAS) or equivalent and re-assembling the fans and connecting with flexible copper wire of one mtr length and testing after repair complete all as specified and directed.
Taking down exhaust fan of 450/300 mm sweep and removing/cleaning the dust properly including oiling and greasing complete all as directed.
Re-winding of exhaust fan motor of 450/300 mm sweep with appropriate size of super enameled copper wire, including re-assembling the fans and connecting with flexible copper wire of one mtr length complete all as directed.
Supply and Fixing in repairs Condenser 2.5 Mfd make universal/Usha /Bajaj/Epcos.
Supply and Fixing in repairs Condenser 3.5 Mfd make universal/Usha /Bajaj/Epcos.
Supply and Fixing in repairs bush of fans of any size complete all as directed.
Supply and Fixing in repairs insulating rubber real including Supply and replacing nuts, bolts with washers complete all as specified and directed
Supply and Fixing in repairs shaft of fans (as per sample) of suitable size complete all as specified and directed
Supply and Fixing in repairs of fan pins of suitable size for various type of fans / ceiling fans complete all as specified and directed.
Supply and Fixing in repairs fan down rod made out of 15 mm dia medium grade GI pipe, Med grade including threading on both end of pipe, drilling holes etc. as required including primer complete all as specified and directed.
Supply and Fixing in repairs fan conopy, suitable for various type ceiling fan all as per sample and directed.
M&L for replacement and re-filling of glass wool as per norms of different type of geysers complete all as specified and directed by the Engr in Charge.
Taking down of unserviceable bolt of existing geyser, M&L grouting of new bolt (tee type) at new place and refixing of geyser of any type and any capacity all as speified and directed by Engr in Charge.
S&F in repairs heating element 2.0 KW as triangular type/ circular type as per sample all as directed by the Engr in Charge.
S&F only new inner shell of geyser capacity 25/35 liters of suitable size made of copper sheet of 22 SWG complete with all suitable accessories complete all as specified and directed.
M&L for replacement of bottom cover in two parts of MS sheets not less than 22 gauge and pre treated in finished in white stove enameled paint as per existing size gauge in the geyser of any capacity/size complete all as specified and directed.
Supply only new safety pressure valve with vent to geysers as per latest ISI specification and directed.
M&L for Painting the outer surface of geyser capacity 25/35 ltrs as per original shade with two coats of synthetic enamel paint over a coat of primer by spray gun after scrapping the existing paint ,denting etc. filling depression with putty and refixing the geyser in position including water/electric connection and testing complete all as specified and directed.
M&L for Brazing/ welding to inner copper tank at leaking spots up to five leakage of geyser of capacity 25/35/50 liters of any type and make of tank after checking up worn out nuts bolts and washers complete all as specified and directed.
S&F assemblly of geyser 25/35/50 ltr.capacity as specified and directed by Engg. In charge.
Supply and Fixing in repairs Indicator lamp with new indicating lamp round/square, rectangular type as required at site, SP 230Volt
Supply and Fixing in repairs PVC connection flexible heavy grade 45 cm long complete with chromium plated flair nuts with washers at both ends suitable for GI tubing 15 mm bore complete all as specified and directed.
Supply and Fixing in repairs thermostat 0 to 90 degree, ISI marked, 15 Amps capacity automatic cut off at desired temp of suitable size for Geyser
Supply and Fixing in repairs Plug top 15 Amps Make Anchor or equivalent complete all as specified.
Dismantling,inspection,repairing and re assembling after replacement of UNSV parts ie circiut and all electronic controls etc for homogeneous and shadow less light with min temp rise complete all as specified and directed.making serviceable shadowless light fitting complete function including testing after repair and replacement of Note: The cost of OT bulb will be paid under item No 83 and the cost of other spares deemed to be included in the quoted rate.
Dis assembling ,inspection,cleaning and servicing of 1.0 kVA UPS of OT/ICU backup at MH Bly and assembling including testing after making necessary repair/replacement of resistors,capacitors, transformer, PCB circuits, relays , batteries etc complete all as specified and directed. Note: The cost of batteries will be paid under item No . 76 The cost of other spares deemed to be included in the quoted rate.
Supply only UPS batteries 12 V, 7 AH Make Exide/Amron/or equivalent complete all as specified and directed.
M&L for opening ,inspection,cleaning and servicing of 2.5 kVA UPS of OT/ICU backup at MH Bly and assembling including testing after making necessary repair/replacement of resistors,capacitors,transformer, LM relays , PCB circuits , hardware of appropriate capacity match with existing UPS incl replacement of battery etc complete all as specified and directed. NOTE:- The cost of batteries will be paid under item No 78. The cost of other spares deemed to be included in the quoted rate.
Supply only UPS batteries 12 V 65 AH Make Exide/Amron/or equivalent complete all as specified and directed.
M&L for opening ,inspection,cleaning and servicing of 5 kVA UPS of OT/ICU backup at MH Bly and assembling including testing after making necessary repair/replacement of resistors,capacitors,transformer, LM relays , PCB circuits , hardware of appropriate capacity match with existing UPS incl replacement of battery etc complete all as specified and directed. NOTE:- The cost of batteries will be paid under item No 80 . The cost of other spares deemed to be included in the quoted rate.
Supply only UPS batteries 12 V 150 AH Make Exide/Amron/or equivalent complete all as specified and directed.
Supply and fixing name plate light smart decorative light of min. 6W of make C&S, Surya, Crompton or equivalent complete all as specified all as directedby Engr-in-Charge.
M&L for opening ,inspection,cleaning and servicing of movable light for backup at MH Bly including testing after making necessary repair/replacement of spare parts ie resistors,capacitors,transformer, LM relays , PCB circuits , hardware of appropriate capacity match with existing light incl replacement of battery etc complete all as specified and directed. NOTE:- The cost of batteries will be paid under item No 80 . The cost of other spares deemed to be included in the quoted rate.
M&L for earthing complete with galvanised steel earth plate electrode 600 x 600x 6.0 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel and connecting to main switch or switch board complete and incl PCC masonry pit of 300x300x300mm interier diamentions in PCC 1:2:4 type B1 RCC cover with GI frame, charcoal and common salt 15cm in layers all round the earth plate, 15mm dia GI watering pipe, a funnel with wire mesh should be provided on top of watering pipe complete all as specified including testing after completion.
Notes :- (i) For ser No. 02 to 44 items the Contractor has to complete the work assigned for above items with in 36 hours failing in which recovery at the rate 25 Rs. per day per complaint. (ii) For Serial No 51 to 56, 59 to 87: The Contractor has to complete the work assigned for above items with in 60 hours failing in which recovery at the rate 25 Rs. per day per complaint. (iii) The contractor has to maintain a separate complaint slip book and complaint register for attending complaint. The contractor rep have to collect daily complaint slip from the E/M complaint cell and get them signed from user after completing the job and submit to E/M complaint cell.
Repair to Split Type/Window Type AC 1/1.5/2.0 TON
Maintenance and Servicing of split type air conditioner of capacity 1.5/2.0 TR of any make and type by removing , strip opening, cleaning the dust and dirt from the complete unit, cleaning of air filter, cleaning of condensing and cooling coil and complete outdoor and indoor unit using suitable mild cleaning agent and fresh water, blow drying using air blower, oiling/greasing of blower & condenser fan motor etc re-assembling, re-installing in the original position and testing for proper cooling and smooth functioning.
Maintenance and Servicing of Window type air conditioner of capacity 1.0/1.5/2.0 TR of any make and type by removing , strip opening, and taking out the window type AC from the cabinet frame and cleaning the dust and dirt from the complete unit, cleaning of air filter, cleaning of condensing and cooling coil using suitable mild cleaning agent and fresh water, blow drying using air blower, oiling/greasing of blower & condenser fan motor etc re-assembling, re-installing in the original position and testing for proper cooling and smooth functioning.
Taking down/out unserviceable sealed/rotary/Reciprocating type compressor unit from the outdoor unit of Split type AC/ Window type ACs of makes-Carrier/LG/haier/blue star/Voltas and any other make of capacity 1/1.5/2.0 Ton capacity including flushing of cooling system by Nitrogen gas.
S&F compressor (sealed unit) of following capacity in Split type/window type Air Conditioner complete and testing on full load all as specified and as directed by Engineer-in-Charge
(a) Reciprocating type 1.5 Ton
(b) Reciprocating type 2.0 Ton
(c) Rottery type 1.0 Ton
(d) Rottery type 1.5 Ton
(e) Rottery type 2.0 Ton
S&F in repair of following spares parts of Split type/Window type ACs of capacity 2.0/1.5/1.0 Ton including testing complete after dismantling of old respective unserviceable spares
Supply, fixing , installation ,commissioning and testing of indoor unit complete with remote and valves of capacity 1.5 TR suitable for fixing up in the existing model of outdoor unit of Split ACs complete after disconnecting electrical connection and dismantling/ taking out indoor unit of split type ACs of any make and capacity from any place and installation, commissioning and testing after recharging of refrigerant gas to another location including transportation cutting of hole on wall and making good of disturbed surface with matching colour/distamper all as directed by Engineer-in-Charge.
All as Per Srl Item No 96 above but of indoor unit capacity 2.0 Ton
S & F Remote suitable for various makes of Split type/Window ACs for 1/1.5/2.0 Ton capacity Make: LG , Carrier, Voltas, Bluestar, Hitachi
S & F Condenser motor of outdoor unit for 1.5/2.0 Ton capacity of AC as per existing makes
S & F Indoor motor of Blower for 1.5/2.0 Ton capacity of split AC as per existing makes
S & F Condenser PVC blade of fan motor for 1.5/2.0 Ton Split AC
S & F SP plug and socket in sheet steel enclosure including SP MCB 32 Amps Make : HPL/Havells/L&T
S & F Running capacitor 50/2,/50/6 Mfd of suitable size make Epcos/Asian/Max/Sharda or equivalent as per ISI for ACs
S & F Running capacitor 45 Mfd of suitable size make Epcos/Asian/Max/Sharda or equivalent as per ISI for ACs
S & F Starting capacitor 100/120 Mfd of suitable size make Epcos/Asian/Max/Sharda or equivalent as per ISI for ACs
S & F Indoor capacitor of size 1.5 MFD/2 MFD suitable for 1.5/2.0 Ton AC
S & F Swing motor suitable for indoor unit of 1.5/2.0 Ton Split type AC
S & F Contactor suitable for 1.5/2.0 Ton AC as per make/size approved by Engr-in-Charge . L&T/C&S/SIEMENS
S & F Copper tubing of size 3/8" including cutting and brazing all as directed by Engr-in-Charge
S & F Copper tubing of size 5/8" including cutting and brazing all as directed by Engr-in-Charge
S & F Copper tubing of size 1/4" including cutting and brazing all as directed by Engr-in-Charge
S & F Copper tubing of size 1/2" including cutting and brazing all as directed by Engr-in-Charge
S&F three core connection lead two single core, PVC insulated and sheathed Copper cable size 2.5 Sqmm including one earth wire of full guage complete all as specified and as directed
S & F Nitril vinyl insulation foam suitable for fixing with copper tube of size 3/8", 5/8" , 1/2" and 1/4" and packing with wide pvc tapes of black/white colour compete all as specified and directed.
S & F Reverse valve suitable for 1.5/2 ton ACs including dismantling and reinserting of valve and refilling of reqd refrigerant and testing all as specified and directed by Engr-in-Charge
S & F Shifting/Fixing by disconnecting electrical connection and dismantling/ taking out indoor and outdoor unit of split type air conditioning of any make and capacity from any place and installation, commissioning and testing to another location including transportation cutting of hole on wall and making good of disturbed surface with matching colour/distamper all as directed by Engineer-in-Charge.
S & F Shifting/Fixing by disconnecting electrical connection and dismantling/ taking out window type air conditioning complete with frame cabinet of any make and capacity from any place and installation, commissioning and testing to another location including transportation cutting of hole on wall and making platform complete with wooden strip/iron frame for fixing of Window AC Cabinet and making good of disturbed surface with matching colour/distamper all as directed
Taking down unserviceable PCBs card with sensors of Split/Window type AC and refix the same after complete repair and testing as of Cap 1.5/2.0 ton as directed by Engr-in-charge.
Supply and gas charging with refrigerent gas required in any make and type of split and window type ACs to its full capacity where less gas detected in the split type and window type air conditioners complete all as specified by Engr in charge
Notes :- Tenderers may note that amount as given in schedule of credit will be deducted from the total amount to worked out the net contract sum at the time of Acceptance of tender.
M/S MAHIRA ENTERPRISES
N S ELECTRICALS
S S ELECTRICALS
D K THUKRAL AND SONS
SONI ENTERPRISES
LEEJA ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .