| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 CrRejected-Finance 357 KOTKAPURA ROAD STREET NO 8 MUKTSAR PUNJAB 152026 | SRI MUKTSAR SAHIB | PUNJAB | 152026 | ₹1.8 Cr | L1 | Rejected-Finance Rejected |
| 2 | L2₹2.3 Cr+₹43.7 L (23.9%)Rejected-Finance 464 21 NEW ANAJ MANDI TOHANA 125120 | FATEHABAD | HARYANA | 125120 | ₹2.3 Cr+₹43.7 L (23.9%) | L2 | Rejected-Finance Rejected |
Tender Value
₹1.4 Cr
EMD Value
₹2.8 L
Closing Date
4 Feb 2020, 3:00 pmClosed
Sumit Garg, Executive Engineer
Dussehra Ground , Model Town Yamuna Nagar
Providing Sewerage facilities to 7 Nos. villages i.e. Aurangabad Ishopur Patashgarh Mandebri Panjeton Ka Majra Kheri Rangran Sasoli in MC YNR Under CM A. No. 10054 Const. of 2 Nos. IPS at Panjeton Ka Majra and Sasauli Laying of DI Rising Main
2019_HRY_113583_3
EIC No.124462-PHED/Urban Dt.19/12/2019(YNR-2)
Open Tender
Civil Works
Works
365 days
Yamunanagar
Please refer Tender documents.
3 documents required · 3 mandatory
₹15,000
Yes
Engineer in Chief
₹2.8 L
Yes
31 Aug 2020
27 Jan 2020
4 Feb 2020
27 Jan 2020
4 Feb 2020
27 Jan 2020
Amount
Sub Head No. 9 = N.S items for Machinery and Rising Main( for Sasauli)
Supply, fabrication, fixing and testing of stainless steel(ss-304) manual coarse bar screen with flat bar 50mm x 10mm spacing of bar 20mm suitable for mounting in channel of specifier size with inclination not more then 60 degree and movable covers containers of 1 cum capacity in all respect as per technical specification and the direction of Engineer-in-charge.
Supply & Erection of non clog submersible sewage pump with suitable electrical motors with accessories as described in Schedule No. II complete in all respect with submersible cable of suitable size 10 M double length with complete base frame, lifting monorail, chain guide line, auto coupling and shackle (CS) chain. complete in all respects. Non clog sewage submersible pumps (i) 471 M 3 / Hour x 15 M head
-do- Non Clog Sewage submersible pumps (ii) 210 M 3 / Hour x 15 M head
Supplying & fixing following CI/ DF pipe and specials / bell mouth including cost of jointing materials, excavation, laying, jointing, refilling including making adequate supports of masonry / concrete/ steel for delivery and suction pipe from bell mouth in the underground tank upto the rising main as per plan shown from the foundation wall of the pump chamber for non clog Sub. Sewage pumping set at Disposal works as per specification given in schedule. B) Suction of CI/ DF pipes i) 200 mm i/d
do- C) Delivery of CI/DF pipes i) 200mm i/d
-do- D) Bell Mouth i) 200m i/d
-do- B) Suction of CI/ DF pipes i) 150 mm i/d
-do- C) Delivery of CI/DF pipes i) 150mm i/d
-do- D) Bell Mouth i) 150mm i/d
-do- Suitable for 20 BHP (210 cum x 15 Head).
Supply, errection, testing & commissioning in LT cables PVC aluminum armoured / copper cable including cost of thimbles, lugs for making connection underground covered with sand and bricks / in trench / in pipe on steel bridges (detail of cable sizes & length to be provided be clearly mentioned for making following connection: -a) from transformer to LT panel 1100 V grade 3.1/2 core 70 Sq. mm XLPE
Supply, erection, testing & commissioning in LT cables PVC aluminum armoured / copper cable including cost of thimbles, lugs for making connection underground covered with sand and bricks / in trench / in pipe on steel bridges (detail of cable sizes & length to be provided be clearly mentioned for making following connection: -a) Cable for mortor side 3 core aluminum 2x25 sq.mm XLPE.
Providing and fixing of insulated rubber matting suitable for 11 KV installation 1 M x 2 M x 3 mm / as per pannel SPEC for sites as per specification given in schedule. As per IS code 15652-4006
Supplying, erection, testing of Exhaust fans each having a capacity of 45 cubic metres per minutes complete with suitable GI sheet ducting in pump chamber if required.
Supplying, erection, testing Ceiling fans 48" i/d (1200 mm) with suitable GI pipe complete in all respects.
Gantry with chain pulley blocks of 3 tones capacity (tested to 4.50 T) with traveling trolley of appropriate lifting capacity for handling of pumping sets, capable of moving along the girders including cost of suitable size RCC pillars to be constructed over collecting tank complete in all respects as per detailed specifications mentioned in NIT.
Supply, erection, testing & commissioning of diesel generating set 62.50 KVA/50 KW radiator cooled, 3 Phase , 4wire , 50 cycles 415 + (-) 1% volts AC alternator coupled directly through a set of flexible coupling on a common M.S.fabricated base frame with diesel engine. complete description as per approved NIT . The rating should be at 1500 RPM. (a) Diesel Engine (b) Alternator (c) Base plat (d) Bettery 24 V (e) 2x50 Sq. mm 4 core copper cable = 20 Mtr. (f) Tools A.M.F. Panel (a) Motorized chain over switch 100 Amp- 4P with fuse base and HRC links 100 Amp (b) Under voltage/ over voltage relay – 2 No. 415 V.A.C. (c) Engine start relay 24 V D C – 1 No (d) Electronic Timer 24 V D C- 1 No (e) Electronic Timer 24 V A C – 3 No (f) Auxiliary relay 220 V A C – 2 No (g) Auxiliary relay 220 V D C – 3 No (h) Metering set 415 V A C – 1 set ( Amp. Meter , Volt Meter , ASS, VSS , Phase Indicate , Control fuse, frequency meter , CT’S ) (i) Metering set 24 V DC ( Amp Meter , Volt Meter ) (j) Over load protection for DC – 1 No (k) Battery Charger 24 V DC. (Bluetron make). (l) Copper bus bar of suitable size (m) KWH meter 96 square mm size (n) Starting fuse button and key switch ( On / Off). (o) Engine Protection unit with Audiovisual alarm and shut down for low lubricating oil pressure and high coolant temperature . (p) Indicating lumps for low lubricated oil pressure high coolant temperature , set running , load on, DC control on. Note :- Control panel shall have the provision to provide auto manual failure panel (AMFP).
Supply and fixing of oil immersed, copper wound distribution transformer of 100 KVA with offload tappings switch complete as per IS 2026 and IS 335, as per details given in schedule VI, to the entire satisfaction of engineer-in-charge.
Sub Head No. 9 = N.S items for Machinery and Rising Main( for Panjeton Ka Majra)
Supply, fabrication, fixing and testing ofstainless steel(ss-304) manual coarse bar screen with flat bar 50mm x 10mm spacing of bar 20mm suitable for mounting in channel of specifier size with inclination not more then 60 degree and movable covers containers of 1 cum capacity in all respect as per technical specification and the direction of Engineer-in-charge.
Supply & Erection of non clog submersible sewage pump with suitable electrical motors with accessories as described in Schedule No. II complete in all respect with submersible cable of suitable size 10 M double length with complete base frame, lifting monorail, chain guide line, auto coupling and shackle (CS) chain. complete in all respects.Non clog sewage submersible pumps (i) 52 M 3 / Hour x 15 M head
-do- Non Clog Sewage submersible pumps (ii) 25 M 3 / Hour x 15 M head
Supplying & fixing following CI/ DF pipe and specials / bell mouth including cost of jointing materials, excavation, laying, jointing, refilling including making adequate supports of masonry / concrete/ steel for delivery and suction pipe from bell mouth in the underground tank upto the rising main as per plan shown from the foundation wall of the pump chamber for non clog Sub. Sewage pumping set at Disposal works as per specification given in schedule. B) Suction of CI/ DF pipes i) 150 mm i/d
-do- C) Delivery of CI/DF pipes i) 150mm i/d
-do- D) Bell Mouth i) 150m i/d
-do- B) Suction of CI/ DF pipes i) 150 mm i/d
-do- C) Delivery of CI/DF pipes i) 150mm i/d
-do- D) Bell Mouth i) 150mm i/d
-do- Suitable for 3 BHP (25 cum x 15 M Head).
Supply, errection, testing & commissioning in LT cables PVC aluminum armoured / copper cable including cost of thimbles, lugs for making connection underground covered with sand and bricks / in trench / in pipe on steel bridges (detail of cable sizes & length to be provided be clearly mentioned for making following connection: -a) from transformer to LT panel 1100 V grade 3.1/2 core 10 Sq. mm XLPE
Supply, erection, testing & commissioning in LT cables PVC aluminum armoured / copper cable including cost of thimbles, lugs for making connection underground covered with sand and bricks / in trench / in pipe on steel bridges (detail of cable sizes & length to be provided be clearly mentioned for making following connection: -a) Cable for mortor side 3 core aluminum 2x6 sq.mm XLPE.
Providing and fixing of insulated rubber matting suitable for 11 KV installation 1 M x 2 M x 3 mm / as per pannel SPEC for sites as per specification given in schedule. As per IS code 15652-4006
Supplying, erection, testing of Exhaust fans each having a capacity of 45 cubic metres per minutes complete with suitable GI sheet ducting in pump chamber if required
Supplying, erection, testing Ceiling fans 48" i/d (1200 mm) with suitable GI pipe complete in all respects.
Gantry with chain pulley blocks of 3 tones capacity (tested to 4.50 T) with traveling trolley of appropriate lifting capacity for handling of pumping sets, capable of moving along the girders including cost of suitable size RCC pillars to be constructed over collecting tank complete in all respects as per detailed specifications mentioned in NIT.
Supply, erection, testing & commissioning of diesel generating set 15 KVA/10 KW radiator cooled, 3 Phase , 4wire , 50 cycles 415 + (-) 1% volts AC alternator coupled directly through a set of flexible coupling on a common M.S.fabricated base frame with diesel engine. complete description as per approved NIT . The rating should be at 1500 RPM. (a) Diesel Engine (b) Alternator (c) Base plat (d) Bettery 24 V (e) 2x25 Sq. mm 4 core copper cable = 20 Mtr. (f) Tools A.M.F. Panel (a) Motorized chain over switch 100 Amp- 4P with fuse base and HRC links 100 Amp (b) Under voltage/ over voltage relay – 2 No. 415 V.A.C. (c) Engine start relay 24 V D C – 1 No (d) Electronic Timer 24 V D C- 1 No (e) Electronic Timer 24 V A C – 3 No (f) Auxiliary relay 220 V A C – 2 No (g) Auxiliary relay 220 V D C – 3 No (h) Metering set 415 V A C – 1 set ( Amp. Meter , Volt Meter , ASS, VSS , Phase Indicate , Control fuse, frequency meter , CT’S ) (i) Metering set 24 V DC ( Amp Meter , Volt Meter ) (j) Over load protection for DC – 1 No (k) Battery Charger 24 V DC. (Bluetron make). (l) Copper bus bar of suitable size (m) KWH meter 96 square mm size (n) Starting fuse button and key switch ( On / Off). (o) Engine Protection unit with Audiovisual alarm and shut down for low lubricating oil pressure and high coolant temperature . (p) Indicating lumps for low lubricated oil pressure high coolant temperature , set running , load on, DC control on. Note :- Control panel shall have the provision to provide auto manual failure panel (AMFP).
Bidder Name
Amount
Sunil Kumar
Ashok Kumar Contractor
Sunil Kumar
Sunil Kumar
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .