| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.0 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹19.9 L+₹1.9 L (10.6%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹23.0 L+₹5.0 L (28.1%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST | |
| 4 | Rejected-Technical | - | Rejected-Technical AMOUNT OF WORK EXECUTED NOT ADEQUATE | |
| 5 | Rejected-Technical 214 2ND FLOOR SAMRUDDHI COMMERCIAL PREMISES CHINCHOLI BUNDER ROAD MINDSPACE MALAD WEST | - | Rejected-Technical 1. LICENCE FROM GRAM PANCHAYAT NOT ACEEPTABLE 2. FOR THE PERIOD OF 2019-20 |
Tender Value
₹27 L
Closing Date
14 Aug 2020, 1:00 pmClosed
DIRECTOR, ICAR-CIFRI BKP
ICAR CIFRI MONIRAMPORE BARRACKPORE 700120
Construction of Garages (3 nos) along with staircase in the Institute premises at ICAR-CIFRI Barrackpore
2020_DARE_573319_1
4/20/BKP
Open Tender
Civil Works
Works
45 days
ICAR-CIFRI BARRACKPORE
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹0
Exempted
14 Oct 2020
24 Jul 2020
17 Aug 2020
24 Jul 2020
14 Aug 2020
24 Jul 2020
Amount
Dismantling roofing including ridges, hips valleys and gutters etc. and stacking the material within 50 metres lead of----Asbestos sheet
Earth work in excavation by mechanical means ( Hydraulic excavation )/ maulal means in foundation trenches or drains ( not exceeding 1.5 m in width or 10 sqm on plan ), including dressing of sides and ramming of bottoms, lift upto 1.5 including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50m-----All kinds of soil
Filling available excavated earth (excluding rock ) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cem in depth, consolidating each deposited layer by ramming and watering, lead up to 50m and lift upto 1.5 m.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidation and dressing complete
Proding and laying in position cement concrete of specified grade excluding the cost of centring and shuttering-All work upto plinth level. -----------------------------------------------------------------1:2:4 ( ( 1 Cement : 2 Coarse sand ( zone-III) : 4 graded stone aggregate 20 mm nominal size )
Same for -----------------------------------------------------------------------------------------------------------------------------1:5:10 ( 1 Cement : 5 coarse sand ( zone-III) : 10 graded stone aggregate 20 mm nominal size
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement- All work up to plinth level--------1:1.5: 3 ( 1 Cement : 1.5 coarse sand (Zone-III) : 3 graded stone aggregate 20 mm nominal size.
Re inforced cement concrete work in walls ( any thickness ), including attached pilasters, buttress, plinth and string courses, buttress, plinth and string courses, fillets, columns, pillars, piers, abutmens, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement---------1:1.5:3 ( 1 Cement : 1.5 coarse sand ( zone-III) : 3 graded stone aggregate 20 mm nominal size )
Reinforced cement concrete work in beams, suspended floors roofs having slope up to 15 landings balconies, shelves, chajjas, lintents , bands, plan in windows sill, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 ( 1Cement : 1.5 coarse sand ( Zone-III) : 3 graded stone aggregate 20 mm nominal size )
Centring and shuttering including strutting, propping etc. and removal of from for al heights ----------Foundations, footins bases of columns, etc. for mass concrete
Suspended floors, roofs, landings , balconies and access platform-
Columns, Pillars, piers, Abutmets, Posts and Struts
Steel reinforcement for R.C.C. work including straighterning, cutting, bending, placing in position and binding all complete upto plinth level--------------Thermo-Mechanically Treated bars of grade FE-500D or more
Brick work with common burnt clay FPS ( non-modular) bricks of class designation 7.5 in Superstructure above plinth level up to V level in all shapes and sizes in--------------Cement mortar 1:6 ( 1Cement : 6 Coarse sand )
Half brick manonary with common burnt clay FPS ( non modular ) bricks class designation 7.5 in superstructure above plinth level up to floor V level-----------Cement mortar 1:4 ( 1 Cement : 4 Coarse sand )
12 mm Cement Plaster of mix------------1:4 (1 Cement : 4 Coarse sand)
20 mm cement plaster of mix-----------1: 4 ( 1 Cement : 4 coarse sand )
6 mm cement plaster of mix-------------1:3 ( 1 Cement : 3 fine sand )
Finishing walls with premium acrylic smooth exterior paint with silicone additives of required shade------------New work ( Two or more coats applied @ 1.43 litrs/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg. /10 sqm.
Neat cement punning
Cement concrete flooring 1:2:4 ( 1 cement : 2 coarse sand :4 graded stone aggregate ) finished with a floating coat of neat cement ,including cement slurry, but excluding the cost of nosing of steps etc. Complete------------40 mm thick with 20 mm nominal size stone aggregate
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fastners of required dia & length ( hold fast lugs or dash fastner shall be paid for separately)----------------------Sal wood
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelleing which will be paid for separately, all complete as per direction of Engineer-in-Charge-------------Kin seasoned and chemically treated hillock wood-------------------35 mm thick shutters
Providing and fixing paneling or paneling and glazing in paneled or paneled and glazed for doors, windows and clerestory windows ( Area of opening for panel inserts exluding portion inside grooves or rebates to be measured ) . Panelling for paneled or paneled and glazed shutters 25mm to 40 mm thick--------------Kiln seasoned and chemically treated hillock wood
Providing and fixing bright finished brass tower bolts ( barrel type ) with necessary screws etc. Complete----------------250 X 10 mm
Providing and fixing ISI marked oxidized M.S. handles conforming to IS : 4992 with necessary etc. Complete---------------125 mm
Providing and fixing bright finished brass tower bolts-----------(barrel type ) with necessary screws etc. Complete----------300 X 16 mm
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade-----------Two or more coats on new work
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete------------------Fixed to openings /wooden frames with rawl plugs screws etc.
Providing and fixing precoated galvanized iron profile sheets (size,shape and pitch of corrugated as approved by Engineer-in-charge) 0.50mm (+ 0.05% ) total coated thickness with zince coating 120 grms per sqm as per IS : 277, in 240 mpa steel grade, 5-7 microns minimum to avoid scratches during transportation and should be suppled in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of sizge (5.5X55 mm) with EPDM seal, complete upto any pitch in horinontal/vertical or curved surfaces, excluding the cost purlins rafters and trusses and including cutting to size and shape wherever required.
Steel work in built up tubular ( round,square or rectangular hollow tubes etc. ) trusses etc. including cutting, hoisting , fixing in position and applyin a priming coat of approved steel primer , including welding and bolted with special shaped washers etc. Complete---------------Hot finished seamless type tubes
Providing and fixing on wall face unplasticised Rigid PVC pipes conforming to IS : 13592 Tyep A, including jointing with seal ring conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, I) Single socketed pipes -----------110 mm diameter
Providing and fixing unplasticised –PVC pipe clips of approved design to unplasticised-PVC rain water pipes by menas of 50X50X50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 ( 1 cment : 4 coarse sand ) and making good the wall etc. Complete-----------------110 mm
Providing and fixing 1 mm thick M.S.sheet door with frame of 40X40X6 mm angle iron and 3 mm M.S. gusset , plates at the junctions and corners all necessary fittings complete, including applying a priming coat of approved steel primer -------------Using M.S. angles 40X40X6 mm for diagonal braces
Providing and fixing T –irong frames for doors , windows and ventilators of mild steelTee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer-----------Fixing with 15X3 mm lugs 10 cm long embedded in cement concrete block 15X10X10 cm 1:3:6 ( 1cement :3 coarse sand : 6 graded stone aggregate 20 nominal size )
Providing and fixing in position collapsible steel shutters with vertical channels 20X10X2 mm and braced with flat iron diagonals 20X5 mm size, with top and bottom rail of T-iron 40X40X6 mm , with 40mm dia steel pulleys, complete with bolts, nuts locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer.
Casement window double panels with SS friction hinges ( 300X19X1.9 mm) made of (small series ) frame 47X50 mm , sash 47X 68 mm & mullion 47X68mm all having wall thickness of 1.9 + 0.2 mm and single glazing bead of appropriate dimension ( Area of window above 0.75 sqm upto 1.5 sqm )
Distempering with 1st quality acrylic distemper (ready mixed ) of approved manufacturer, of required shade and clour complete , as per manufacturer’s specification -----------------Two or more coats on new work
Electrical--------------------------------------------------------------------------------------------------------------------------Wiring for light point/fan point/exhaust fan point/call bell point 15 sq mm FRLS PVC insulated copper conduction single core cable in surface/recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sqm mm FRLS PVC insulated copper conductor single core cable etc. as required ------------Group C
JADAV CONSTRUCTION
BEE ROMEN
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .