Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 CrAccepted-AOC 508 ASHOK BHAWAN 93 NEHRU PLACE NEW DELHI DELHI 110019 | SOUTH EAST DELHI | DELHI | 110019 | ₹1.9 Cr | L1 | Accepted-AOC As per NIT Terms and condition, Purchase price preference to eligible MSME Bidder was given. |
| 2 | L1₹1.9 CrRejected-AOC C6 2ND FLOOR MALVIYA NAGAR SOUTH DELHI DELHI 110017 | SOUTH DELHI | DELHI | 110017 | ₹1.9 Cr | L1 | Rejected-AOC Non-divisible contract |
| 3 | Rejected-Technical FLAT NO 1A ROYAL PLAZA 3 FEEDER ROAD BELGHARIA KOLKATA WEST BENGAL 700056 | 24 PARAGANAS NORTH | WEST BENGAL | 700056 | - | - | Rejected-Technical Work Order and its completion certificate submitted does not meets the Work Experience criteria of NIT |
| 4 | Not Admitted-Fee 5TH FLOOR MAHESH SHAH 5TH FLOOR PREMISES NO 03 415 PECON TOWER PLOT NO DH 6 38 NEW TOWN RAJARHAT KOLKATA WEST BENGAL 700156 | 24 PARAGANAS NORTH | WEST BENGAL | 700156 | - | - | Not Admitted-Fee Others-EMD Declaration as per Annexure – II has not been submitted. Hence, bid has been rejected as per NIT Section – II Clause 29 – ‘Outright Bid Rejection Criteria’ & NIT Section – II Clause 3.1 Sub-point 4. |
Tender Value
₹2.1 Cr
EMD Value
₹4.1 L
Closing Date
21 May 2022, 6:00 pmClosed
Joint General Manager (IT)
RHQ ER Kolkata 700052
Comprehensive AMC of IT Infrastructure and associated IT Support Services for RHQ ER and ER Airports except Raipur, Bhubaneshwar, Patna and Deoghar
2022_AAI_114032_1
AAI/ER/IT/NIT/2022-23/01
Open Tender
Information Technology
Tender cum Auction
365 days
As per NIT
Please refer Tender documents.
22 documents required · 22 mandatory
₹2,950
Yes
₹4.1 L
Yes
19 Jul 2022
6 May 2022
23 May 2022
7 May 2022
21 May 2022
7 May 2022
7 May 2022 - 11 May 2022
Amount
RHQ-ER, Kolkata
Onsite Hardware Maintenance Engineer for effective implementation of the entire scope of work as defined in NIT under Section - IV (Special Terms and Conditions of the Contract) Point#1 (Scope of Work). The Contractor has to engage the minimum 8 no. High Skilled manpower including relievers etc. as defined in NIT under Section - IV (Special Terms and Conditions of the Contract) Point#1 (Scope of Work)
Onsite Support for effective implementation of the entire scope of work as defined in NIT under Section - IV (Special Terms and Conditions of the Contract) Point#1 (Scope of Work). The Contractor has to engage the minimum 1 no. Skilled manpower including relievers etc. as defined in NIT under Section - IV (Special Terms and Conditions of the Contract) Point#1 (Scope of Work)
Onsite Application Support Engineer for Supporting E-Office Application/GeM/E-Tender (CPP Portal)/SAP FI/ SAP MM/ Other In-house application of AAI as defined in NIT under Section - IV (Special Terms and Conditions of the Contract) Point#1 (Scope of Work). The Contractor has to engage the minimum 6 no. High Skilled manpower including relievers etc. as defined in NIT under Section - IV (Special Terms and Conditions of the Contract) Point#1 (Scope of Work)
Onsite Network Support Engineer for Supporting AAI Network as defined in NIT under Section - IV (Special Terms and Conditions of the Contract) Point#1 (Scope of Work). The Contractor has to engage the minimum 3 no. High Skilled manpower including relievers etc. as defined in NIT under Section - IV (Special Terms and Conditions of the Contract) Point#1 (Scope of Work)
Onsite Support for effective implementation of the entire scope of work as defined in NIT under Section - IV (Special Terms and Conditions of the Contract) Point#1 (Scope of Work). The Contractor has to engage the minimum 4 no. Semi- Skilled manpower including relievers etc. as defined in NIT under Section - IV (Special Terms and Conditions of the Contract) Point#1 (Scope of Work)
Driver for effective implementation of the entire scope of work as defined in NIT under Section - IV (Special Terms and Conditions of the Contract) Point#1 (Scope of Work). The Contractor has to engage the minimum 1 no. Skilled driver including relievers etc. as defined in NIT under Section - IV (Special Terms and Conditions of the Contract) Point#1 (Scope of Work)
Deployment of Vehicle 1 no – SUV Segment dedicated vehicle, preferably Bolero / TUV300 / Sumo / Qualis / Tavera / Force One or equivalent with minimum monthly usage of 1300 km X 221 Hours, Service – local i.e. travel within the city limits or upto 50 km of one-way travel, whichever is higher, Fuel included
Comprehensive AMC of Desktop Computers
Comprehensive AMC of All in One PC
Comprehensive AMC of Laptop excluding laptop battery
Comprehensive AMC of UPS <1KVA excluding batteries
Comprehensive AMC of UPS 1KVA excluding batteries
Comprehensive AMC of Online UPS 1KVA excluding batteries
Comprehensive AMC of Online UPS 2KVA excluding batteries
Comprehensive AMC of Online UPS 3KVA excluding batteries
Comprehensive AMC of Online UPS 6KVA excluding batteries
Comprehensive AMC of MFD A4 Mono
Comprehensive AMC of MFD A4 Colour
Comprehensive AMC of A3 Mono
Comprehensive AMC of A3 Colour
Comprehensive AMC of High-Speed Scanner
Comprehensive AMC of Flatbed Scanner
Comprehensive AMC of Layer 2 Switch 8port
Comprehensive AMC of Layer 2 Switch 24port
Comprehensive AMC of Layer 2 Switch 48port
Comprehensive AMC of Layer 3 Switch
Comprehensive AMC of Display Screen 75"
Comprehensive AMC of Display Screen 49"
Comprehensive AMC of Projector
Comprehensive AMC of Speaker
Comprehensive AMC of Microphone
Comprehensive AMC of Amplifier
Comprehensive AMC of AEBAS Devices
Comprehensive AMC of Tablets
Comprehensive AMC of Server
Inventory Management Software for Usage Only
Complaint Management Software for Usage Only
Pakyong
Onsite Hardware Maintenance Engineer for effective implementation of the entire scope of work as defined in NIT under Section - IV (Special Terms and Conditions of the Contract) Point#1 (Scope of Work). The Contractor has to engage the minimum 1 no. High Skilled manpower including relievers etc. as defined in NIT under Section - IV (Special Terms and Conditions of the Contract) Point#1 (Scope of Work)
Onsite Support for effective implementation of the entire scope of work as defined in NIT under Section - IV (Special Terms and Conditions of the Contract) Point#1 (Scope of Work). The Contractor has to engage the minimum 1 no. Semi- Skilled manpower including relievers etc. as defined in NIT under Section - IV (Special Terms and Conditions of the Contract) Point#1 (Scope of Work)
Comprehensive AMC of Desktop Computers
Comprehensive AMC of Laptop excluding laptop battery
Comprehensive AMC of UPS 1KVA excluding batteries
Comprehensive AMC of MFD A4 Mono
Comprehensive AMC of Layer 2 Switch 48port
Comprehensive AMC of AEBAS Devices
Inventory Management Software for Usage Only
Complaint Management Software for Usage Only
Onsite Hardware Maintenance Engineer for effective implementation of the entire scope of work as defined in NIT under Section - IV (Special Terms and Conditions of the Contract) Point#1 (Scope of Work). The Contractor has to engage the minimum 1 no. High Skilled manpower including relievers etc. as defined in NIT under Section - IV (Special Terms and Conditions of the Contract) Point#1 (Scope of Work)
Onsite Support for effective implementation of the entire scope of work as defined in NIT under Section - IV (Special Terms and Conditions of the Contract) Point#1 (Scope of Work). The Contractor has to engage the minimum 1 no. Semi- Skilled manpower including relievers etc. as defined in NIT under Section - IV (Special Terms and Conditions of the Contract) Point#1 (Scope of Work)
Comprehensive AMC of Desktop Computers
Comprehensive AMC of Laptop excluding laptop battery
Comprehensive AMC of UPS <1KVA excluding batteries
Comprehensive AMC of UPS 1KVA excluding batteries
Comprehensive AMC of MFD A4 Mono
Comprehensive AMC of MFD A4 Colour
Comprehensive AMC of High-Speed Scanner
Comprehensive AMC of AEBAS Devices
Comprehensive AMC of Layer 2 Switch 24port
Comprehensive AMC of Layer 2 Switch 48port
Comprehensive AMC of Web Came
Comprehensive AMC of Projector
Comprehensive AMC of Speaker
Comprehensive AMC of Document Visualiser
Inventory Management Software for Usage Only
Complaint Management Software for Usage Only
Bagdogra
Onsite Hardware Maintenance Engineer for effective implementation of the entire scope of work as defined in NIT under Section - IV (Special Terms and Conditions of the Contract) Point#1 (Scope of Work). The Contractor has to engage the minimum 1 no. High Skilled manpower including relievers etc. as defined in NIT under Section - IV (Special Terms and Conditions of the Contract) Point#1 (Scope of Work)
Onsite Support for effective implementation of the entire scope of work as defined in NIT under Section - IV (Special Terms and Conditions of the Contract) Point#1 (Scope of Work). The Contractor has to engage the minimum 1 no. Semi- Skilled manpower including relievers etc. as defined in NIT under Section - IV (Special Terms and Conditions of the Contract) Point#1 (Scope of Work)
Comprehensive AMC of Desktop Computers
Comprehensive AMC of Laptop excluding laptop battery
Comprehensive AMC of UPS <1KVA excluding batteries
Comprehensive AMC of UPS 1KVA excluding batteries
Comprehensive AMC of MFD A4 Mono
Comprehensive AMC of A3 Mono
Comprehensive AMC of High-Speed Scanner
Comprehensive AMC of Flatbed Scanner
Comprehensive AMC of AEBAS Devices
Comprehensive AMC of Projector
Inventory Management Software for Usage Only
Complaint Management Software for Usage Only
Coochbehar
Onsite Hardware Maintenance Engineer for effective implementation of the entire scope of work as defined in NIT under Section - IV (Special Terms and Conditions of the Contract) Point#1 (Scope of Work). The Contractor has to engage the minimum 1 no. High Skilled manpower including relievers etc. as defined in NIT under Section - IV (Special Terms and Conditions of the Contract) Point#1 (Scope of Work)
Comprehensive AMC of Desktop Computers
Comprehensive AMC of UPS <1KVA excluding batteries
Comprehensive AMC of UPS 1KVA excluding batteries
Comprehensive AMC of MFD A4 Mono
Comprehensive AMC of MFD A4 Colour
Inventory Management Software for Usage Only
Complaint Management Software for Usage Only
Ranchi
Onsite Hardware Maintenance Engineer for effective implementation of the entire scope of work as defined in NIT under Section - IV (Special Terms and Conditions of the Contract) Point#1 (Scope of Work). The Contractor has to engage the minimum 1 no. High Skilled manpower including relievers etc. as defined in NIT under Section - IV (Special Terms and Conditions of the Contract) Point#1 (Scope of Work)
Onsite Support for effective implementation of the entire scope of work as defined in NIT under Section - IV (Special Terms and Conditions of the Contract) Point#1 (Scope of Work). The Contractor has to engage the minimum 1 no. Semi- Skilled manpower including relievers etc. as defined in NIT under Section - IV (Special Terms and Conditions of the Contract) Point#1 (Scope of Work)
Comprehensive AMC of Desktop Computers
Comprehensive AMC of Laptop excluding laptop battery
Comprehensive AMC of UPS 1KVA excluding batteries
Comprehensive AMC of MFD A4 Mono
Comprehensive AMC of MFD A4 Colour
Comprehensive AMC of High-Speed Scanner
Comprehensive AMC of Flat Bet Scanner
Comprehensive AMC of Layer 2 Switch 8port
Comprehensive AMC of Layer 2 Switch 24port
Comprehensive AMC of Layer 2 Switch 48port
Inventory Management Software for Usage Only
Complaint Management Software for Usage Only
Jharsuguda
Onsite Hardware Maintenance Engineer for effective implementation of the entire scope of work as defined in NIT under Section - IV (Special Terms and Conditions of the Contract) Point#1 (Scope of Work). The Contractor has to engage the minimum 1 no. High Skilled manpower including relievers etc. as defined in NIT under Section - IV (Special Terms and Conditions of the Contract) Point#1 (Scope of Work)
Onsite Support for effective implementation of the entire scope of work as defined in NIT under Section - IV (Special Terms and Conditions of the Contract) Point#1 (Scope of Work). The Contractor has to engage the minimum 1 no. Semi- Skilled manpower including relievers etc. as defined in NIT under Section - IV (Special Terms and Conditions of the Contract) Point#1 (Scope of Work)
Comprehensive AMC of Desktop Computers
Comprehensive AMC of Laptop excluding laptop battery
Comprehensive AMC of UPS <1KVA excluding batteries
Comprehensive AMC of UPS 1KVA excluding batteries
Comprehensive AMC of Online UPS 2KVA
Comprehensive AMC of MFD A4 Mono
Comprehensive AMC of MFD A4 Colour
Comprehensive AMC of High-Speed Scanner
Comprehensive AMC of Flat Bet Scanner
Comprehensive AMC of Access Point
Comprehensive AMC of Layer 2 Switch 8 port
Comprehensive AMC of Layer 2 Switch 48 port
Comprehensive AMC of Layer 3 Switch
Inventory Management Software for Usage Only
Complaint Management Software for Usage Only
Port Blair
Onsite Hardware Maintenance Engineer for effective implementation of the entire scope of work as defined in NIT under Section - IV (Special Terms and Conditions of the Contract) Point#1 (Scope of Work). The Contractor has to engage the minimum 1 no. High Skilled manpower including relievers etc. as defined in NIT under Section - IV (Special Terms and Conditions of the Contract) Point#1 (Scope of Work)
Onsite Support for effective implementation of the entire scope of work as defined in NIT under Section - IV (Special Terms and Conditions of the Contract) Point#1 (Scope of Work). The Contractor has to engage the minimum 1 no. Semi- Skilled manpower including relievers etc. as defined in NIT under Section - IV (Special Terms and Conditions of the Contract) Point#1 (Scope of Work)
Comprehensive AMC of Desktop Computers
Comprehensive AMC of Monitor
Comprehensive AMC of Laptop excluding laptop battery
Comprehensive AMC of UPS <1KVA excluding batteries
Comprehensive AMC of UPS 1KVA excluding batteries
Comprehensive AMC of MFD A4 Mono
Comprehensive AMC of MFD A4 Colour
Comprehensive AMC of High-Speed Scanner
Comprehensive AMC of Flat Bet Scanner
Comprehensive AMC of Layer 2 Switch upto 24port
Comprehensive AMC of Layer 2 Switch 28port
Comprehensive AMC of Projector
Comprehensive AMC of Microphone
Comprehensive AMC of Amplifier
Inventory Management Software for Usage Only
Complaint Management Software for Usage Only
Darbhanga
Onsite Hardware Maintenance Engineer for effective implementation of the entire scope of work as defined in NIT under Section - IV (Special Terms and Conditions of the Contract) Point#1 (Scope of Work). The Contractor has to engage the minimum 1 no. High Skilled manpower including relievers etc. as defined in NIT under Section - IV (Special Terms and Conditions of the Contract) Point#1 (Scope of Work)
Onsite Support for effective implementation of the entire scope of work as defined in NIT under Section - IV (Special Terms and Conditions of the Contract) Point#1 (Scope of Work). The Contractor has to engage the minimum 1 no. Semi- Skilled manpower including relievers etc. as defined in NIT under Section - IV (Special Terms and Conditions of the Contract) Point#1 (Scope of Work)
Comprehensive AMC of Desktop Computers
Comprehensive AMC of UPS <1KVA excluding batteries
Comprehensive AMC of UPS 1KVA excluding batteries
Comprehensive AMC of MFD A4 Mono
Comprehensive AMC of Layer 2 Switch 24port
Inventory Management Software for Usage Only
Complaint Management Software for Usage Only
RHQ – ER and all ER Airports except Raipur, Bhubaneshwar, Patna & Deoghar
Supply of Laptop batteries (Li-ion or better) with minimum Working Hour Capacity 8 hours with 1-year Warranty
Supply of UPS batteries with 1-year warranty (7Ah, 12V)
Supply of UPS batteries with 1-year warranty (9Ah, 12V)
Supply of UPS batteries with 1-year warranty (18Ah, 12V)
Supply of UPS batteries with 1-year warranty (26Ah, 12V)
Supply of Wired Keyboard and USB Mouse (3.0) Combo with at least 1-year OEM Warranty
Supply of Wireless keyboard & Mouse with compatible Alkaline batteries for both keyboard & Mouse. Both items should have minimum 1-year OEM Warranty.
Supply of Metal Pen drive 64GB USB 3.0 with minimum 1-year OEM Warranty.
Supply of Portable SSD 500GB with minimum 1-year OEM Warranty
Supply of Ultra-High-Speed HDMI Cable (2m)
Supply of Ultra-High-Speed HDMI Cable (5m)
Supply of Ultra-High-Speed HDMI Cable (10m)
Supply of 4GB RAM DDR 4 with minimum 1 year warranty
Laying of CAT6/CAT6A UTP/ Outdoor UTP/ Outdoor STP Cable through Channel/ Conduit/ Raceway/ Cable Tray/ HDPE Pipe/ GI Conduit / Wall etc. CAT 6/CAT6A UTP/Outdoor UTP/STP/ OFC cable should be laid through Conduit/ Channel / Raceway /Cable Tray/ HDPE Pipe/ GI Conduit of required size on the wall surface or/ through trench/raceway etc. as per site requirement. Proper clamping or fixing should be done for assuring stability & finishing, as required. Proper distance from electrical cable should be maintain to reduce electromagnetic interference. Proper marking/ferruling/Tagging if applicable should be done at both end of cable run.
Fixing, Termination, Testing and Commissioning of IO Box (Single Module) including Back box & Face plate with Marking. Proper fixing back box on wall/ furniture/ as per site requirement should be done. Termination of Information Outlet (dual/single) as per the IT standard should done. Proper marking/ferruling/Tagging if applicable should be done.
Fixing, Termination, Testing and Commissioning of IO Box (Dual Module) including Back box & Face plate with Marking. Proper fixing back box on wall/ furniture/ as per site requirement should be done. Termination of Information Outlet (dual/single) as per the IT standard should done. Proper marking/ferruling/Tagging if applicable should be done.
Crimping and Testing of RJ45 Connector. Crimping of RJ45 connector should be done with professional tool kit.
Laying of Outdoor/Indoor OFC Cable 12 Core SM through HDPE Pipe/ GI Conduit/Raceway/ Cable Tray etc.
Laying of Outdoor/Indoor OFC Cable 6 Core SM through HDPE Pipe/ GI Conduit/Raceway/ Cable Tray etc.
Fixing, Termination, Testing and Commissioning of Outdoor Enclosure for 12 Core OFC including Pigtail Connectors, Patch Cords, Splicing, Marking etc.
Fixing, Termination, Testing and Commissioning of Outdoor Enclosure for 6 OFC including Pigtail Connectors, Patch Cords, Splicing, Marking etc.
Laying of PVC/ Metal Flexible. Flexible shall be used in conduit bents / joints / rack end/ as per site requirement. Flexibles should be tightly fixed to the corresponding conduits in joints. No Gaps should be left between the joints.
Laying of HDPE Pipe/ GI Conduit through Wall/ Raceway/ Cable Tray/ Existing Trench etc. Required size HDPE/GI conduit should be laid through the wall/ Raceway/ Cable Tray/ Existing Trench surface as per site requirement. Marking for identification with suitable material should be done. Proper clamping (metal/PVC) & fixing at suitable distance should be done for assuring stability & finishing of laid Pipe/Conduit. Coupler as per site requirement should be used.
Laying of HDPE Pipe/ GI Conduit through Soft Soil digging and back filling with sand & brick. Required size HDPE/GI conduit should be laid through soft soil. Coupler as per site requirement should be used to join the conduits. Digging of soft soil includes earth digging & back filling the trench with sand & bricks and finally compacting the trench with excavated soil. The depth of the trench from top of the surface shall be approx. 100 cm and minimum 20 cm width. Sand & bricks filling up to 80 cm from below & rest soil compacting (earth surface side).
Laying of HDPE Pipe/ GI Conduit through Hard Soil digging and back filling with sand & brick. Required size HDPE/GI conduit should be laid through the hard soil. Coupler as per site requirement should be used to join the conduits. Digging of hard soil includes earth digging & back filling the trench with sand & bricks and finally compacting the trench with excavated soil. The depth of the trench from top of the surface shall be approx. 100 cm and minimum 20 cm width. Sand & bricks filling up to 80 cm from below & rest soil compacting (earth surface side).
Laying of HDPE Pipe/ GI Conduit through Concrete cutting and back filling with sand & brick including restoration of Concrete. Required size HDPE/GI conduit should be laid inside the concrete. Coupler as per site requirement should be used to join the conduits. Laying through the concrete includes concrete cutting & back filling with sand & bricks and restoration with concrete The depth of the trench from top of the surface shall be approx. 30 cm and minimum 10 cm back filling with Sand & brick Final, restoration with concrete should be ensured.
Laying of HDPE Pipe/ GI Conduit through Road cutting and back filling with sand & brick including restoration of Road. Required size HDPE/GI conduit should be laid inside the road. Laying through the Road includes road cutting either by making trench on the surface or by drilling across the roads. The road should be dig and refilled with sand & brick including restoration of Road. Or manual boring /drilled at suitable depth below the road & restoration with sand & bricks.
Laying of HDPE Pipe/ GI Conduit through Micro- Tunnelling (HDD). Required size HDPE/GI conduit should be laid through micro tunnel. Tunnel hole should be in line with the respective conduit size. Micro tunneling or HDD should be done at a depth of minimum 3 meter. Conduit joining should be done with proper Joint Kit/ coupler as per the industry standard. All kinds of gaps or leakages should be fixed.
Laying/ Fixing of PVC Channel/ Conduit/ Box Channel through Wall/ Raceway/ Cable Tray/ Existing Trench/ False Ceiling etc. Through Wall Required size PVC Channel/Conduit/ Box channel/Tray should be laid through the wall surface as per site requirement. Proper clamping (metal/PVC) & fixing at suitable distance should be done for assuring stability & finishing of laid product. Required size of joint kit/Coupler should be used at joints & bending. Marking for identification with suitable material should be done. Through Raceway/ Cable Tray/ Existing Trench/ False Ceiling etc. Required size PVC Channel/Conduit/ Box channel/Tray should be laid on existing Raceway/ Cable Tray/ Existing Trench/ False ceiling etc as per site requirement. Proper clamping (metal/PVC) & fixing in suitable distance should be done for assuring stability & finishing of laid product. Marking for identification with suitable material should be done.
Laying & Fixing of Tray through Wall/Raceway/Trench/ Ceiling etc. Through Wall Required size PVC Channel/Conduit/ Box channel/Tray should be laid through the wall surface as per site requirement. Proper clamping (metal/PVC) & fixing at suitable distance should be done for assuring stability & finishing of laid product. Required size of joint kit/Coupler should be used at joints & bending. Marking for identification with suitable material should be done. Through Existing Trench/ False Ceiling etc. Required size PVC Channel/Conduit/ Box channel/Tray should be laid on Existing Trench/ False ceiling etc as per site requirement. Proper clamping (metal/PVC) & fixing in suitable distance should be done for assuring stability & finishing of laid product. Marking for identification with suitable material should be done.
Supply, Fixing & Installation of Manhole Chambers along with Cover. Size: Min Depth 3 feet, Min. breadth 2 feet, Min. Width 2 feet. Thickness: Min. 50mm (+-10%) Non-Corrosive Metal Cover should be provided. Cover should have a handle for lifting it. Shape: Preferable Square Fixing of Chamber along with digging of Soil/Soil cutting as per requirement, refilling with a layer of Sand/Brick/ combination of both, then a layer of Brick & over that a layer of PCC.
Bidder Name
Amount in Words
Sirius Global Limited
IND INNOVATIONS PRIVATE LIMITED
Sirius Global Limited
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .